Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

Similar documents
FIRE SUPPRESSION SYSTEM

Specification/ Data Sheet

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.

Carbon Dioxide Fire Suppression Systems

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

Data/ Specification Sheet

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

GAS FLOODING SYSTEM FOR CIFF AT BASEMENT

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

SECTION CLEAN AGENT FIRE SUPPRESSION SYSTEMS

SECTION TOTAL FLOODING ECARO-25 CLEAN AGENT FIRE EXTINGUISHING SYSTEM

Superior by Design The Kidde ADS TM FM-200 System

The Amerex Advantage - Quality Experienced Innovation Made in the USA

Safe, Effective, Environment-friendly

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

SPECIFICATION: ARGONITE Engineered Fire Suppression System

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE CHEETAH Xi 50 CONTROL PANEL SYSTEM

Liberty Township Fire Department Fire Prevention Bureau. Clean Agent Fire Protection Plan Submittal Checklist

Fire alarm system specification for multiple tenant retail buildings

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

SECTION INTRUSION DETECTION

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPUSLE VALVE, Fike FK AGENT & SHP PRO CONTROL PANEL

BOC FS125 The Fire Extinguishing Solution

HFC-227ea FIRE SUPPRESSION SYSTEM

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

Hospitals and Major Medical Centers

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

Types of Detection. Fusible Link Detection - Most Common

Release Control Fire Alarm Systems

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

PAIRED UNJACKETED. Insulation Nominal Anixter. Paired Conductors Thickness O.D. Number AWG Strand No. IN IN

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

CO2 COCO GAS FLOODING SYSTEM

FLAME DETECTOR ADAPTERS 8832 through 8839 and Series R Bulletin 8832

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi CONTROL PANEL

EXTINGUISHING SYSTEM DETECTION AND CONTROL

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

SECTION FIRE ALARM SYSTEMS

SECTION : FIRE ALARM & DETECTION SYSTEMS

How can you minimize consequential damages in case of a fire?

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL

A. Work Included: Provide an engineered, fixed piped clean agent total flooding Clean Agent fire

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

An Overview of Extinguishing Systems for Computer Equipment

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi 50 CONTROL PANEL

Service Bulletin No. 2930

Fire Safety Compliance

CORE Protection Fire System Specification

Engineering Specifications

CLEAN AGENT SYSTEMS. TABLE 1 Agents Recognized in NFPA 2001

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

Water Mist Fire Suppression

IN2 Lighting Control Devices

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

CO 2. fire extinguishing systems

Oberon s National Electric Code (NEC)Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

SECTION INTRUSION DETECTION SYSTEM

TrueAlarm Analog Sensing

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

Sinorix Engineered Fire Suppression Systems For use with Novec TM 1230 Fire Protection Fluid and HFC-227ea

Innovative protection that combines power and flexibility

SECTION (16140) - WIRING DEVICES

B. Special Documentation Requirements. C. Materials and methods of Construction

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

SECTION FM-200 FIRE SUPPRESSION SYSTEM

THE WORLD LEADER. in special hazard fire suppression solutions

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

Copyright 2013 Fike 12/13 SECTION CLEAN-AGENT FIRE-EXTINGUISHING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SENTRY PRODUCTS, INC. 01/98 SCAN - STAND-ALONE - Sample Specification

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

KIDDE WHDR WET CHEMICAL FIRE SUPPRESSION AND INTELLIGENT CONTROL SYSTEM FOR COOKING OPERATIONS WITH ARIES-NET MULTI-LOOP INTELLIGENT CONTROL UNIT

Industrial Dry Chemical Fire Suppression System

Linear Heat Detection Engineering Specifications

Vista-50P/-50PUL System Design Sheet

CERTIFICATE OF APPROVAL No. ME 5005 EMIRATES FIRE FIGHTING EQUIPMENT FACTORY LLC (FIREX)

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

LORAIN CIP 4890/48120 DC Power System

DAF DETECT-A-FIRE. DAF DETECT-A-FIRE Detection and Release Devices

Transcription:

Amerex Clean Agent System with FM200 Utilizing the industry recognized FM-200 suppression agent, Amerex has developed an affordable pre-engineered clean agent fi re suppression system to protect areas with sensitive electrical equipment and valuable data. As an industry leader in innovative design of products that provide the quality and performance you expect, Amerex has developed the CPS system to be the most cost effi cient clean agent system available. The modular design incorporates pre-assembled wiring harnesses and keyed locking connectors on all electrical components to assist you in a simple and confi dent installation. Agent tanks are available in two sizes having a diameter of ten inches making tank location in confi ned spaces less stressful. Tanks are charged with FM-200 in increments of two pounds in a small tank or three pounds in a larger tank for a custom installation without un-necessary expense. Electrical actuators are used for system actuation and can be reset reducing the number of components to be replaced during service after discharge. The CPS system is designed to use schedule 40 pipe giving you easy access to the materials you need to complete the installation. Nozzles are available in three designs; corner, side wall, and center room for fl exibilty in system installation to protect those challenging areas. The Amerex CPS is monitored by an electrical control panel that has a battery back-up for 24 hour protection during power failure. Photoelectric smoke detectors are used for detection and are cross zoned to reduce the potential for unwanted system discharge. A bell and horn strobe device alarm when fi re conditions are present. All electrical circuits are supervised and factory terminated. Potential Applications: Data Processing Server Rooms Electronic Data/Tape Storage UPS Rooms TELCO PBX & IDF Rooms Cell Sites Microwave relay Towers Industrial Process Control Rooms Laboratories Engine Test Cells Flammable Liquid Storage Rooms Broadcasting Radio & TV Stations Electronic Control Rooms UPS Rooms Media Storage Historic Record Storage Healthcare Medical Record Storage CT/CAT Scan & MRI Control Rooms Cultural Museums Libraries Personal/Corporate Collections Miscellaneous Bank Vaults Cash/Security Departments Precious Inventory System Coverage Overview: Maximum of 22,000 ft3 using multiple cylinders (approximately 3,700 ft3 per cylinder) One nozzle per cylinder Each nozzle covers a 44 ft. radius Two cylinder sizes with multiple options on agent fi ll weight Approvals and Standards: Underwriters Laboratories, Inc. (UL) Underwriters Laboratories of Canada (ULC) Factory Mutual (FM) NFPA 2001 Clean Agent Fire Extinguish ing Systems ISO-14520 Gaseous Fire Extinguishing Systems EPA SNAP Program

Agent: The extinguishing agent used in the Amerex CPS is FM-200 manufactured by Great Lakes Chemical, A Chemtura Company. The chemical name for the agent is Heptafl uoropropane (CF3CH- FCF3), identifi ed in NFPA 2001 as HFC-227ea. This agent was developed as an environmentally safe alternative to Halon 1301 and is intended to prevent business interruption due to the risks of fi re and to prevent the loss of irreplaceable, high value assets from fi re. HFC-227ea is on the U. S. Environmental Protection Agency s (EPA) Signifi cant New Alternatives Policy (SNAP) Program list as acceptable for use in occupied spaces. HFC-227ea is included in NFPA 2001, Standard on Clean Agent Fires Extinguishing Systems with exposure limits of 5 minutes for design concentrations up to 10.5%. The primary extinguishing mechanism of HFC-227ea is heat absorption. It absorbs heat at the molecular level faster than the amount of heat generated by the combustion reaction and essentially ceases the combustion reaction since it cannot sustain itself. Although the physical mechanism of heat removal is the predominant mechanism of fl ame extinguishment, there is a chemical contribution to fl ame extinguishment which arises from the thermal decomposition of small amounts of HFC-227ea in the fl ame. For an automatically operated fi re suppression system protecting Class A hazards a minimum design concentration of 7.0% by volume is recommended. For systems protecting Class A hazards that are manually operated a minimum design concentration of 7.6% by volume is required. Typically, Class B hazards have higher extinguishing concentrations and all Class B systems are designed with a 30% safety factor. BASIC SYSTEM LAYOUT: AGENT CYLINDER ALARM DEVICE HORN / STROBE DISCHARGE NOZZLES SMOKE DETECTORS RELEASING PANEL MANUAL PULL

CLEAN AGENT PRE-ENGINEERED SYSTEMS LABORATORIES REMOTE SERVERS AUDIO/VISUAL TELECOMMUNICATIONS DATA PROCESSING

RECORDS AND DOCUMENT STORAGE RECORDS AND DOCUMENT STORAGE LABORATORIES FIRE EXTINGUISHERS SHOULD BE AVAILABLE TO PROTECT AREAS OUTSIDE THE COVERAGE AREA. A FIRE HAZARD ANAYLYSIS SHOULD BE PERFORMED PRIOR TO SYSTEM INSTALLATION TO ASSURE PROPER AND BALANCED FIRE PROTECTION.

Amerex Clean Agent Agent Tanks: Available in two sizes, each having a diameter of ten inches. Tanks are charged with FM200 in increments of two pounds in a small tank or three pounds in the larger tank. The tanks are pressurized to 360 psi @ 70 F and available in agent weights of 16 to 44 lbs. or 46 to 130 lbs. respectively. Agent tanks are constructed of low carbon steel and have an epoxy primer and polyurethane paint fi nish. Discharge valve assembly consists of brass and stainless steel components with rubber seals. Mechanical and Electrical actuators for system discharge. Up to 5 additional agents tanks can be actuated using pneumatic actuators for a total of 6 simultaneously discharged tanks. Each agent tank includes a factory installed low pressure switch to monitor the tanks condition and signal the releasing panel if pressure drops below 285 psi. A unique dual-outlet valve provides capability to protect two rooms of different sizes, or a room and under fl oor with one tank. Electric Releasing Control Panel: Provides supervised circuit monitoring and contains a back-up battery providing 24 hour protection during power failure. Detection / Manual Actuation: Photoelectric smoke detectors are cross zoned to reduce potentially unwanted discharge. Detectors are provided with keyed locking connectors. Wiring harnesses are factory assembled in pre-determined lengths and are equipped with matching keyed locking connectors. The manual pull stations, used to release the system, are double action. A combination pull station/abort is available that includes an abort switch. Alarming Device: A bell and horn/strobe design give both audible and visual indication that fi re conditions are present. An alarm bell rings when smoke is detected and the horn/strobe operates to signal the start of the release time delay.

System Components CABLE: Cable assemblies used on all circuits except the release circuit are 4-conductor plenum rated cable type CMP complying with NFPA 70 (National Electrical Code) Article 760 for use on power limited fi re alarm circuits. Each of the four conductors is stranded 18 AWG copper with extruded insulation. An aluminum shield covers the 4 conductors with a white mylar outer jacket. The release circuit is non-power limited and the cable assembly is type NPLF complying with NFPA 70 (National Electrical Code) Article 760 for use on non-power limited fi re alarm circuits. This 2-conductor cable assembly is rated for 600 volts. Each conductor is stranded 18 AWG copper with fl ame retardant PVC insulation and an aluminum/polyester shield covers the pair. The outer jacket is black, fl ame retardant, low temperature with a temperature rating of 90 C. Single four conductor cable assemblies and single two conductor release cable assemblies can be pulled through ½ conduit feeding/ pulling the receptacle end through, multiple cable assemblies run in conduit should use ¾ or larger conduit. Since the release circuit is non-power limited the release circuit cable must run in its own conduit or raceway. Each device and each cable assembly include four position, keyed, locking connectors. The connectors are Molex brand Mini-Fit Jr. model. The plug and receptacle housings have a UL fl ammability rating of 94V-0. The terminals are gold plated to reduce oxidation contamination and provide good electrical connections for the low voltage and low current circuits of the releasing panel. Discharge Pressure Switch: The discharge pressure switch is used to send a signal to the releasing panel when the valve has been opened. In addition to sending a positive signal of automatic actuation it also serves as an initiating device sending a signal to secure the protected room if the valve has been operated manually by the manual local actuator. Amerex provides this discharge pressure switch with a pre-installed wire harness for connection to the panel using a junction box harness and cable assemblies. Nozzles: Brass discharge nozzles are available in three confi gurations; a 90 1-orifi ce nozzle for corner of room locations, a 180 two orifi ce nozzle for side wall locations, and a 360 four orifi ce nozzle for center of room locations. Two and four orifi ce nozzles have their orifi ces on 90 degree centers.