Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display User Manual

Similar documents
Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

Ambient Weather WS-16 8-Channel Wireless Thermometer with Min/Max Display User Manual

Ambient Weather WS Channel Wireless Thermometer with Min/Max Display User Manual

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

Ambient Weather WS-DP02 Digital Psychrometer with Temperature, Humidity, Heat Index, Dew Point, Wet Bulb Temperature and Clock User Manual

Ambient Weather WS-09 8-Channel Wireless Refrigerator/Freezer Thermometer User Manual

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

Ambient Weather WS-25 Wireless 8-Channel Floating Pool and Spa Thermometer with Indoor Temperature and Humidity User Manual

Ambient Weather RC-9362 Atomic Digital Wall Clock with Temperature User Manual

Ambient Weather RC-8487 ClearView Radio Controlled Travel Alarm Clock with Indoor Temperature User Manual

Ambient Weather RC-8461 ClearView Jumbo Atomic Digital Wall Clock with Temperature and Humidity User Manual

WS-110 Wireless 8 Channel Advanced Weather Station with Temperature Spectrum Color Changing Backlight User Manual

Ambient Weather RC-8419 ClearView Radio Controlled Projection Alarm Clock with Indoor Temperature User Manual

Ambient Weather RC-8365 ClearView Radio Controlled Projection Clock with Indoor Temperature User Manual

Ambient Weather RC-8365 ClearView Radio Controlled Projection Clock with Indoor and Outdoor Temperature User Manual

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

Ambient Weather WS-MOF0831-CTH Gold Dial Cherry Wood Weather Station with Temperature, Humidity and Quartz Clock User Manual

Wireless Color Weather Station

Thermometer model 02059

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

WS-8300U 915 MHz Wireless Weather Station Instruction Manual

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

Thermometer with Wired Sensor

Instruction Manual. AcuRite Atlas Outdoor Device model 06059

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

Model: WS-9133U-IT Quick Setup Guide DC: WIRELESS FORECAST STATION

WS-9023U 915 MHz Wireless Weather Station. Instruction Manual

WS-12 Wireless 8 Channel Professional Weather Station with Temperature Spectrum Color Changing Backlight User Manual

Contents. English. French. Spanish

Projection Alarm Clock

WIRELESS COLOR WEATHER STATION

ATOMIC DIGITAL CLOCK. Time and Alarm

Atomic Digital Clock Model: Instruction Manual

La Crosse Technology WT-8002U. Digital Clock with Indoor Temperature

Atomic Digital Wall Clock

Ambient Weather WS-1171 Advanced Weather Station User Manual

Weather Station model 02001

WIRELESS COLOR FORECAST STATION

Digital Refrigerator/Freezer Thermometer model 00986

WIRELESS MULTI-ZONE DIGITAL THERMOMETER WITH RADIO CONTROLLED CLOCK. Model No (SF Version) Instruction Manual

Wireless Weather Station. Table of Contents

WIRELESS COLOR WEATHER STATION

Ambient Weather WS-1170 Advanced Weather Station User Manual

Owner s Manual. PIR-1 IR Learner

WIRELESS COLOR FORECAST STATION

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

WIRELESS FORECAST STATION

FEATURES AND SPECIFICATIONS

Weather Forecaster models 75077/75107

Model: S88907 Instruction Manual DC: WIRELESS COLOR WEATHER STATION

Model: WS-8147U-IT Instruction Manual DC: ATOMIC DIGITAL CLOCK WITH MOON PHASE

High Resolution Display WIRELESS COLOR WEATHER STATION

Thermometer with Probe model 00891A

Model: T83653v2 Instruction manual DC: WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location

Model: C Instruction Manual DC: WIRELESS COLOR WEATHER STATION

READ ME FIRST DIY WIRELESS ALERT. Add-on Alert Sensor. For Swann Wireless Alert systems. Instruction Manual

Color Forecast Station. Table of Contents

IMPORTANT. Questions? Contact Customer Support at (877) or visit 5-in-1 PRO+ Weather Sensor model

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

WIRELESS WEATHER STATION

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

Timer Wall Clock. Model: WT-8100U Quick Setup Guide BUTTONS

Copyright Rollibot, LLC. All Rights Reserved USER MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE

Model: C87207 / C87061 Instruction Manual DC: DUAL ALARM CLOCK

Wireless Weather Station

Model: M Instruction Manual DC: WIRELESS COLOR WEATHER STATION Mold Risk for Weather Station & Indoor Remote Sensor Location

DIGITAL ATOMIC WALL CLOCK

Home Doorway Alert Kit

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight

IMPORTANT. 3-in-1 Weather Sensor model SAVE THIS MANUAL FOR FUTURE REFERENCE. Package Contents

Projection Alarm Clock USER GUIDE

WS-2801 Advanced Color Wireless Weather Station User Manual

WS-2812U Wireless Professional Weather Center

IMPORTANT. Display for 5-in-1 Weather Sensor model 06005RM/1010RX SAVE THIS MANUAL FOR FUTURE REFERENCE. Package Contents

Atomic Digital Office Clock

Model:T83646v2 Quick Setup Guide DC: WIRELESS WEATHER STATION

Model: Av2 Quick Setup Guide DC: Atomic Projection Alarm Clock

IN-OUT Thermometer with Cable Free Sensor and Clock

Rain Gauge model 00875

Universal Fan and Light Remote Control

Atomic Projection Alarm Clock

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight

Mood Light and Nature Sound Alarm Clock

100 Ft. LASER DISTANCE METER

Weather Station model 02005TBDI

Weather Station model 01086

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Weather Station model 01120

TOUCH-SCREEN WEATHER STATION MODEL WS Operation Manual

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

WS-8117U-IT ATOMIC CLOCK WITH OUTDOOR WIRELESS TEMPERATURE AND MOON PHASE Instruction Manual

Weather Station models / / 00524

WIRELESS TEMPERATURE & HUMIDITY STATION INSTRUCTION MANUAL

Atomic Digital Office Clock

Humidity Monitor model 01080

Atomic Digital Clock with Temperature and Moon Phase

Atomic Projection Alarm. Model: A Instruction Manual

WS-8055U. Radio Controlled Moon Phase Clock. Instruction Manual

Digital Cooking Thermometer models / 00282

Transcription:

Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display User Manual Table of Contents 1 Introduction... 2 2 Getting Started... 2 Parts List... 2 3 Display Console Layout... 3 4 Display Features... 3 4.1 Comfort Icon... 3 5 Console Operation... 3 5.1 Set Mode... 3 5.2 Day Month/Year/Alarm Display... 4 5.3 Time Alarm... 4 5.4 Reset Max/Min... 4 5.5 Adjustment or Calibration... 4 5.5.1 Humidity Calibration... 5 5.5.2 Temperature Calibration... 5 6 Glossary of Terms... 6 7 Specifications... 6 7.1 Measurement Specifications... 6 7.2 Power Consumption... 6 8 Troubleshooting Guide... 6 9 Accessories... 7 10 Liability Disclaimer... 7 11 FCC Statement... 7 12 Warranty Information... 8 Version 1.0 Copyright 2016, Ambient LLC. All Rights Reserved. Page 1

1 Introduction Thank you for your purchase of the Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display. The following user guide provides step by step instructions for installation, operation and troubleshooting. To download the latest manual and additional troubleshooting tips, please visit: 2 Getting Started http://ambientweather.wikispaces.com/ws26 The WS-26 weather station consists of a display console. Parts List QTY Item 1 Display Console Frame Dimensions (LxHxW): 4.50 x 5.0 x 1.00 in LCD Dimensions (LxW): 3.75 x 3.50 LCD Segment Height: 1.25 inches 1 User Manual 1. Remove the battery door on the back of the display, as shown in Figure 1. Insert four AAA (alkaline or lithium, avoid rechargeable) batteries in the back of the display console. All of the LCD segments will light up for a few seconds to verify all segments are operating properly. Figure 1 2. Replace the battery door, and fold out the desk stand and place the console in the upright position. The console will instantly display time, indoor temperature and humidity as designated by the icon. Version 1.0 Copyright 2016, Ambient LLC. All Rights Reserved. Page 2

3 Display Console Layout 4 Display Features Figure 2 4.1 Comfort Icon The comfort icon is based on humidity ranges specified in Figure 3. The icon is displayed for indoor humidity. RH<45% RH 45%~65% RH >65% 5 Console Operation Dry Comfortable Wet Figure 3 Note: The console has three buttons for easy operation: CLEAR/- button, SET/ADJUST button, and [+] button. 5.1 Set Mode The Set Mode allows you to set the date and time format, date and time, time alarm, units of measure and Min/Max clear. To enter the set mode, press and hold the SET key for 3 seconds 1. 12 hr/24 hr time format. Press the [+] key to switch between 12 and 24 hour format. Press the SET key to advance to the next setting. Version 1.0 Copyright 2016, Ambient LLC. All Rights Reserved. Page 3

2. Hour. Press the [+] or [-] key to increase or decrease the hour. Press the SET key to advance to the next setting. 3. Minute. Press the [+] or [-] key to increase or decrease the minute. Press the SET key to advance to the next setting. 4. Month-Day/Day-Month format. Press the [+] key to switch between mm-dd and dd-mm date format. Press the SET key to advance to the next setting. 5. Month. Press the [+] or [-] key to increase or decrease the month. Press the SET key to advance to the next setting. 6. Day. Press the [+] or [-] key to increase or decrease the day. Press the SET key to advance to the next setting. 7. Year. Press the [+] or [-] key to increase or decrease the year. Press the SET key to advance to the next setting. 8. Alarm Hour. Press the [+] or [-] key to increase or decrease the alarm hour. Press the SET key to advance to the next setting. 9. Alarm Minute. Press the [+] or [-] key to increase or decrease the alarm minute. Press the SET key to advance to the next setting. 10. Temperature Units of Measure. Press the [+] or [-] key to switch between F and C units of measure. Press the SET key to advance to the next setting. 11. Max/Min Clearing. The Max/Min can be programmed to clear daily (at midnight) or manually. Press the [+] or [-] key to switch between Clears Daily and Clears Manually. Press the SET key to exit setting. 5.2 Day Month/Year/Alarm Display Press the SET key (do not hold) to toggle between the Day/Month, Year and Alarm Time. 5.3 Time Alarm To turn on and off the Time Alarm, press the CLEAR/- button and the alarm icon will appear when set, and disappear when disabled. 5.4 Reset Max/Min To reset the Max/Min values, press and hold the CLEAR/- button for 3 seconds. 5.5 Adjustment or Calibration Note: The calibrated value can only be adjusted on the console. Note: The measured humidity range is between 10 and 99%. Humidity cannot be accurately measured outside of this range. Thus, the humidity cannot be calibrated below 10% or above 99%. The purpose of calibration is to fine tune or correct for any sensor error associated with the devices margin of error. The measurement can be adjusted from the console to calibrate to a known source. Calibration is only useful if you have a known calibrated source you can compare it against, and is optional. This section discusses practices, procedures and sources for sensor calibration to reduce manufacturing and degradation errors. Do not compare your readings obtained from sources such as the internet, radio, television or newspapers. They are in a different location and typically update once per hour. The purpose of your weather station is to measure conditions of your surroundings, which vary significantly from location to location. Version 1.0 Copyright 2016, Ambient LLC. All Rights Reserved. Page 4

5.5.1 Humidity Calibration To enter the humidity calibration mode, press and hold the SET/ADJUST and CLEAR/- buttons at the same time for 5 seconds and the humidity value will begin flashing. Press the [+] button to increase the humidity and the CLEAR/- button to decrease the humidity reading in 1% increments. To rapidly increase (or decrease) the humidity reading, press and hold the [+] or CLEAR/- button. To return the humidity to the actual or uncalibrated measurement, press the ADJUST button. Once the displayed humidity equals the calibrated source, press and hold the ADJUST button for three seconds, or wait 15 seconds for timeout, and the humidity value will stop flashing. Discussion: Humidity is a difficult parameter to measure electronically and drifts over time due to contamination. Due to manufacturing tolerances, the humidity is accurate to ± 5%. To improve this accuracy, the humidity can be calibrated using an accurate source, such as a sling psychrometer: http://www.ambientweather.com/mafaredspslp.html or one step humidpak calibration kits (reference Section 9). You can also use common table salt, water and a plastic bag: http://ambientweather.wikispaces.com/ws26 5.5.2 Temperature Calibration To enter the temperature calibration mode, press and hold the SET/ADJUST and [+] buttons at the same time for 5 seconds and the temperature value will begin flashing. Press the [+] button to increase the temperature and the CLEAR/- button to decrease the temperature reading in 0.1 increments. To rapidly increase (or decrease) the temperature reading, press and hold the [+] or CLEAR/- button. To return the temperature to the actual or uncalibrated measurement, press the ADJUST button. Once the displayed temperature equals the calibrated source, press and hold the ADJUST button for three seconds, or wait 15 seconds for timeout, and the temperature value will stop flashing. Discussion: Temperature errors can occur when a sensor is placed too close to a heat source (such as a computer or TV or in a window). To calibrate temperature, we recommend a mercury or red spirit (fluid) thermometer. Bi-metal (dial) and other digital thermometers are not a good source and have their own margin of error. Version 1.0 Copyright 2016, Ambient LLC. All Rights Reserved. Page 5

6 Glossary of Terms Term Accuracy Hygrometer Range Definition Accuracy is defined as the ability of a measurement to match the actual value of the quantity being measured. A hygrometer is a device that measures relative humidity. Relative humidity is a term used to describe the amount or percentage of water vapor that exists in air. Range is defined as the amount or extent a value can be measured. 7 Specifications 7.1 Measurement Specifications The following table provides specifications for the measured parameters. Measurement Range Accuracy Resolution Indoor Temperature 32 to 140 F ± 1 F 0.1 F Indoor Humidity 10 to 99 % ± 5% (only guaranteed between 20 to 90%) 1 % 7.2 Power Consumption Base station (display console) : 4 x AAA 1.5V Alkaline or Lithium batteries (not included) Battery life: Minimum 12 months with high quality batteries. Rechargeable batteries are fine, but may not last as long. 8 Troubleshooting Guide If your question is not answered here, you can contact us as follows: 1. Email Support: support@ambientweather.com 2. Technical Support: 480-346-3398 (M-F 8am to 3pm Arizona Time) Problem Temperature seems inaccurate Humidity seems inaccurate Display console contrast is weak Solution Allow up to one hour for the console to stabilize after installing batteries. Use the calibration feature to match the temperature to a known source. Allow up to one hour for the console to stabilize after installing batteries. Use the calibration feature to match the temperature to a known source. Replace console batteries with a fresh set of batteries. Version 1.0 Copyright 2016, Ambient LLC. All Rights Reserved. Page 6

9 Accessories The following software and hardware accessories are available for this weather station at www.ambientweather.com. Accessory Ambient Weather Humidity Calibration Kits Description One step calibration kits for digital hygrometers use salt slurry formula to accurately calibrate the hygrometer. 10 Liability Disclaimer Please help in the preservation of the environment and return used batteries to an authorized depot. The electrical and electronic wastes contain hazardous substances. Disposal of electronic waste in wild country and/or in unauthorized grounds strongly damages the environment. Reading the User manual is highly recommended. The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place. This product is designed for use in the home only as indication of weather conditions. This product is not to be used for medical purposes or for public information. The specifications of this product may change without prior notice. This product is not a toy. Keep out of the reach of children. No part of this manual may be reproduced without written authorization of the manufacturer. Ambient, LLC WILL NOT ASSUME LIABILITY FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT. 11 FCC Statement Statement according to FCC part 15.19: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. Statement according to FCC part 15.21: Modifications not expressly approved by this company could void the user's authority to operate the equipment. Statement according to FCC part 15.105: NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined Version 1.0 Copyright 2016, Ambient LLC. All Rights Reserved. Page 7

by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. 12 Warranty Information Ambient, LLC provides a 1-year limited warranty on this product against manufacturing defects in materials and workmanship. This limited warranty begins on the original date of purchase, is valid only on products purchased and only to the original purchaser of this product. To receive warranty service, the purchaser must contact Ambient, LLC for problem determination and service procedures. Warranty service can only be performed by a Ambient, LLC. The original dated bill of sale must be presented upon request as proof of purchase to Ambient, LLC. Your Ambient, LLC warranty covers all defects in material and workmanship with the following specified exceptions: (1) damage caused by accident, unreasonable use or neglect (lack of reasonable and necessary maintenance); (2) damage resulting from failure to follow instructions contained in your owner s manual; (3) damage resulting from the performance of repairs or alterations by someone other than an authorized Ambient, LLC authorized service center; (4) units used for other than home use (5) applications and uses that this product was not intended (6) the products inability to receive a signal due to any source of interference or metal obstructions and (7) extreme acts of nature, such as lightning strikes or floods. This warranty covers only actual defects within the product itself, and does not cover the cost of installation or removal from a fixed installation, normal set-up or adjustments, claims based on misrepresentation by the seller or performance variations resulting from installation-related circumstances. Version 1.0 Copyright 2016, Ambient LLC. All Rights Reserved. Page 8