N GNRATION INTRNATIONAL DSIGN GUID
Contents 3 M Series Ovens 12 Series Ovens 24 Convection Steam Ovens 29 Microwave Ovens Features and specifications are subject to change at any time without notice. IMPORTANT NOT: Throughout this guide, dimensions may vary by ± 3. 34 arming Drawers 39 olf arranty
UPPR OVN LOR OVN OLF M SRIS OVNS M Series Ovens Three striking new looks are just the beginning. Superior performance features include an even more advanced dual vertical convection fan system, touch-screen controls, convenient new preset cooking programs and improved interior lighting. There is more usable space inside for deliciousness on a grand scale. M series ovens can be installed in a standard or flush inset application. M SRIS OVNS TRANSITIONAL ICBSO30TM/S/TH ICBSO36TM/S/TH ICBDO30TM/S/TH PROFSSIONAL ICBSO30PM/S/PH ICBDO30PM/S/PH CONTMPORARY ICBSO30CM/B ICBDO30CM/B wolfappliance.com 3
OLF M SRIS OVNS M Series Ovens TRANSITIONAL SINGL OVN 22 218 46 723 51 36 CONDUIT CHANNL 686 IDTH 65 584 BHIND FRAM OPN OVN DOOR 543 TRANSITIONAL DOUBL OVN 22 218 46 51 36 CONDUIT CHANNL 1291 1254 OPN OVN DOOR 543 IDTH 65 584 BHIND FRAM IDTH TRANSITIONAL 762 Model 759 914 Model (single oven only) 911 4 nglish
UPPR OVN LOR OVN OLF M SRIS OVNS M Series Ovens PROFSSIONAL SINGL OVN 22 218 46 51 723 36 CONDUIT CHANNL 686 759 83 584 BHIND FRAM OPN OVN DOOR 543 PROFSSIONAL DOUBL OVN 22 218 46 51 36 CONDUIT CHANNL 1291 1254 OPN OVN DOOR 543 759 83 584 BHIND FRAM wolfappliance.com 5
OLF M SRIS OVNS M Series Ovens CONTMPORARY SINGL OVN 25 218 46 51 723 36 CONDUIT CHANNL 686 759 584 BHIND FRAM OPN OVN DOOR 543 CONTMPORARY DOUBL OVN 25 218 46 51 36 CONDUIT CHANNL 1291 1254 OPN OVN DOOR 543 759 584 BHIND FRAM 6 nglish
OLF M SRIS OVNS Planning Information The M series oven can be installed in a standard or flush inset application. If a cooktop is being installed above an oven, a minimum of 6 is required between units. Location of the electrical supply within the oven opening may require additional cabinet depth. Finish the edges of the opening. They may be visible when the door is open. For standard installations, face trim will overlap stiles and rails. Refer to the chart below. For flush inset installations, a minimum 3 reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90. INSTALLATION RQUIRMNTS BAS SUPPORT Single Oven Double Oven TRIM OVRLAP Top Bottom Sides MIN 115 kg 181 kg 25 0 18 LCTRICAL Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply flush with the back wall and within the shaded area shown in the illustration for your specific installation on the following pages. For ease of installation, the electrical supply for the oven can be placed in an adjacent cabinet within reach of the conduit. Performance may be compromised if the electrical supply is less than 220 volts. The oven is supplied with a single phase and 3-phase convertible power inlet box. The wiring diagram covering the control circuit is provided with the oven. LCTRICAL RQUIRMNTS SINGL OVN SINGL PHAS 3-PHAS Required Power Supply 220-240 V AC 50/60 Hz 380-415 V AC 50 Hz Maximum Connected Load 4.2 4.8 k 3.0 3.6 k DOUBL OVN SINGL PHAS 3-PHAS Required Power Supply 220-240 V AC 50/60 Hz 380-415 V AC 50 Hz Maximum Connected Load 8.4 9.6 k 4.2 4.8 k wolfappliance.com 7
OLF M SRIS OVNS M Series Single Oven STANDARD INSTALLATION 591 OPNING DPTH TOP VI 699 OPNING HIGHT 127 OPNING IDTH 102 SID VI FRONT VI NOT: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. OPNING IDTH SINGL OVN 762 Model 724 914 Model 876 8 nglish
OLF M SRIS OVNS M Series Double Oven STANDARD INSTALLATION 591 OPNING DPTH TOP VI 127 102 1267 OPNING HIGHT OPNING IDTH 432 TYPICAL SID VI FRONT VI NOT: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. OPNING IDTH DOUBL OVN 762 Model 724 wolfappliance.com 9
OLF M SRIS OVNS M Series Single Oven FLUSH INST INSTALLATION 22 OR 25 ** 610 FLUSH INST DPTH FINISHD CLATS* TOP VI FLUSH INST IDTH*** 730 FLUSH INST HIGHT*** 29 127 102 21 3 SID VI FRONT VI *25 minimum depth. Shaded areas will be visible and should be finished to match cabinetry. **22 for professional and transitional models and 25 for contemporary model. ***Dimension provides minimum reveals. NOT: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. FLUSH INST IDTH SINGL OVN 762 Model 765 914 Model 918 10 nglish
OLF M SRIS OVNS M Series Double Oven FLUSH INST INSTALLATION 22 OR 25 ** 610 FLUSH INST DPTH FINISHD CLATS* TOP VI FLUSH INST IDTH*** 29 127 102 1299 FLUSH INST HIGHT*** 21 432 TYPICAL 3 SID VI FRONT VI *25 minimum depth. Shaded areas will be visible and should be finished to match cabinetry. **22 for professional and transitional models and 25 for contemporary model. ***Dimension provides minimum reveals. NOT: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. FLUSH INST IDTH DOUBL OVN 762 Model 765 wolfappliance.com 11
ATR LIGHT TMP MOD OK TIMR TIM OFF ARM LIGHT TMP MOD OK TIMR TIM OFF OLF SRIS OVNS Series Ovens Stainless models now feature a redesigned stainless steel touch-action control panel, helping to create great meals with ease, as well as adding a striking design feature to the kitchen. Smart technology gives the series ten cooking modes, with olf s innovative dual convection in single ovens and in the upper unit of double ovens. olf series ovens are crafted of stainless steel. Tubular handles have been updated to match the rest of the new olf cooking appliance offering, providing a more cohesive family look. series ovens can be installed in a standard or flush inset application. SRIS OVNS TRANSITIONAL ICBSO2418T/S/TH ICBSO24T/S/TH ICBSO30T/S/TH ICBDO30T/S/TH PROFSSIONAL ICBSO30P/S/PH ICBDO30P/S/PH CONTMPORARY ICBSO30C/B/TH ICBDO30C/B/TH 12 nglish
ATR LIGHT TMP MOD OK TIMR TIM OFF ARM LIGHT TMP MOD OK TIMR TIM OFF OLF SRIS OVNS 610 Series Ovens MODL ICBSO2418T/S/TH TRANSITIONAL SINGL OVN 22 538 454 446 597 64 546 BHIND FRAM OPN OVN DOOR 360 MODL ICBSO24T/S/TH TRANSITIONAL SINGL OVN 22 559 597 591 597 64 546 BHIND FRAM OPN OVN DOOR 460 wolfappliance.com 13
OLF SRIS OVNS 762 Series Ovens TRANSITIONAL SINGL OVN 25 244 76 225 708 CONDUIT CHANNL 689 718 759 70 603 BHIND FRAM OPN OVN DOOR 559 TRANSITIONAL DOUBL OVN 25 244 76 225 1280 CONDUIT CHANNL 1261 718 OPN OVN DOOR 559 759 70 603 BHIND FRAM 14 nglish
OLF SRIS OVNS 762 Series Ovens PROFSSIONAL SINGL OVN 25 244 76 225 708 CONDUIT CHANNL 689 718 759 86 603 BHIND FRAM OPN OVN DOOR 559 PROFSSIONAL DOUBL OVN 25 244 76 225 1280 CONDUIT CHANNL 1261 718 OPN OVN DOOR 559 759 86 603 BHIND FRAM wolfappliance.com 15
OLF SRIS OVNS 762 Series Ovens CONTMPORARY SINGL OVN 32 244 76 225 708 CONDUIT CHANNL 687 718 759 76 603 BHIND FRAM OPN OVN DOOR 559 CONTMPORARY DOUBL OVN 32 244 76 225 1280 CONDUIT CHANNL 1257 718 OPN OVN DOOR 559 759 76 603 BHIND FRAM 16 nglish
OLF SRIS OVNS Planning Information The series oven can be installed in a standard or flush inset application. If a cooktop is being installed above an oven, a minimum of 6 is required between units. Location of the electrical supply within the oven opening may require additional cabinet depth. Finish the edges of the opening. They may be visible when the door is open. For standard installations, face trim will overlap stiles and rails. Refer to the chart below. For flush inset installations, a minimum 6 reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90. INSTALLATION RQUIRMNTS BAS SUPPORT MIN 610 Single Oven 68 kg 762 Single Oven 115 kg 762 Double Oven 181 kg TRIM OVRLAP 610 MODL 762 MODL Top 6 13 Bottom 0 3 Sides 17 17 LCTRICAL Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply flush with the back wall and within the shaded area shown in the illustration for your specific installation on the following pages. For ease of installation, the electrical supply for the oven can be placed in an adjacent cabinet within reach of the conduit. Unit is supplied with terminal box convertible to single or 3-phase. The wiring diagram covering the control circuit is provided with the oven. LCTRICAL RQUIRMNTS 610 SINGL OVN lectrical Supply Service Receptacle Power Cord 220-240 V AC, 50 Hz 3400 atts grounding-type (earthed) 1.8 m LCTRICAL RQUIRMNTS 762 SINGL OVN SINGL PHAS 3-PHAS Required Power Supply 220-240 V AC 50/60 Hz 380-415 V AC 50 Hz Maximum Connected Load 4.4 k 4.4 k Total Amps 19 19 762 DOUBL OVN SINGL PHAS 3-PHAS Required Power Supply 220-240 V AC 50/60 Hz 380-415 V AC 50 Hz Maximum Connected Load 7.4 k 5.1 k Total Amps 32 22 wolfappliance.com 17
OLF SRIS OVNS 610 Series Oven STANDARD INSTALLATION 572 OPNING DPTH TOP VI H OPNING HIGHT 562 OPNING IDTH SID VI FRONT VI NOT: lectrical supply must be located in adjacent cabinet within.9 m of opening. OPNING HIGHT 610 SRIS OVN H Model ICBSO2418T/S/TH 449 Model ICBSO24T/S/TH 591 18 nglish
OLF SRIS OVNS 762 Series Single Oven STANDARD INSTALLATION 610 OPNING DPTH TOP VI 692 OPNING HIGHT 127 724 OPNING IDTH 102 SID VI FRONT VI NOT: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. wolfappliance.com 19
OLF SRIS OVNS 762 Series Double Oven STANDARD INSTALLATION 610 OPNING DPTH TOP VI 127 102 1264 OPNING HIGHT 724 OPNING IDTH 432 TYPICAL SID VI FRONT VI NOT: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. 20 nglish
OLF SRIS OVNS 610 Series Oven FLUSH INST INSTALLATION 22 584 FLUSH INST DPTH FINISHD CLATS* TOP VI 13 H FLUSH INST HIGHT** 24 6 610 FLUSH INST IDTH** SID VI FRONT VI *ill be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. NOT: lectrical supply must be located in adjacent cabinet within.9 m of opening. FLUSH INST HIGHT 610 SRIS OVN H Model ICBSO2418T/S/TH 467 Model ICBSO24T/S/TH 610 wolfappliance.com 21
OLF SRIS OVNS 762 Series Single Oven FLUSH INST INSTALLATION 25 OR 32 ** 635 FLUSH INST DPTH FINISHD CLATS* TOP VI 772 FLUSH INST IDTH*** 721 FLUSH INST HIGHT*** 19 127 102 24 10 981 TYPICAL SID VI FRONT VI *ill be visible and should be finished to match cabinetry. **25 for professional and transitional models and 32 for contemporary model. ***Dimension provides minimum reveals. NOT: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. 22 nglish
OLF SRIS OVNS 762 Series Double Oven FLUSH INST INSTALLATION 25 OR 32 ** 635 FLUSH INST DPTH FINISHD CLATS* TOP VI 772 FLUSH INST IDTH*** 19 127 102 1292 FLUSH INST HIGHT*** 24 432 TYPICAL 10 SID VI FRONT VI *ill be visible and should be finished to match cabinetry. **25 for professional and transitional models and 32 for contemporary model. ***Dimension provides minimum reveals. NOT: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. wolfappliance.com 23
ATR LIGHT TMP MOD OK TIMR TIM OFF OLF CONVCTION STAM OVNS Convection Steam Ovens The legacy of the combination oven goes back decades, to innovative chefs in America and urope who embraced the combination of air movement with superheated steam to achieve superior results from breads and roasts to delicate fishes, seafood and vegetables. olf combines the benefits of convection and steam for the most innovative steam oven on the market today. Virtually any dish prepared in a conventional oven, range or microwave can also be prepared in the olf convection steam oven with more control. Two widths and three distinct styles compliment the look of olf ovens, ranges and cooktops. Convection steam ovens can be installed in a standard or flush inset application. CONVCTION STAM OVNS TRANSITIONAL ICBCSO24T/S/TH ICBCSO30TM/S/TH PROFSSIONAL ICBCSO30T/S/TH ICBCSO30PM/S/PH ICBCSO30P/S/PH CONTMPORARY ICBCSO30CM/B/TH 24 nglish
OLF CONVCTION STAM OVNS Convection Steam Ovens TRANSITIONAL 22 538 454 446 IDTH 64 546 BHIND FRAM OPN OVN DOOR 360 IDTH TRANSITIONAL 610 Model 597 762 Model 759 PROFSSIONAL 22 538 454 446 759 83 546 BHIND FRAM OPN OVN DOOR 360 CONTMPORARY 22 538 454 446 759 64 546 BHIND FRAM OPN OVN DOOR 360 wolfappliance.com 25
OLF CONVCTION STAM OVNS Planning Information The convection steam oven can be installed in a standard or flush inset application. The electrical supply for the oven must be located in an adjacent cabinet. Finish the edges of the opening. They may be visible when the door is open. For standard installations, face trim will overlap stiles and rails. Refer to the chart below. For flush inset installations, a minimum 3 reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90. LCTRICAL Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recoended and may cause interruption of operation. Performance may be compromised if the electrical supply is less than 220 volts. INSTALLATION RQUIRMNTS BAS SUPPORT Convection Steam Oven MIN 45 kg TRIM OVRLAP 610 MODL 762 MODL Top 5 5 Bottom 0 0 Sides 18 98 LCTRICAL RQUIRMNTS lectrical Supply Service Receptacle Power Cord 220-240 V AC, 50 Hz 3800 atts grounding-type (earthed) 1.8 m 26 nglish
OLF CONVCTION STAM OVNS Convection Steam Oven STANDARD INSTALLATION 548 OPNING DPTH TOP VI 449 OPNING HIGHT OPNING IDTH SID VI FRONT VI NOT: 610 and 762 models require the same opening dimensions. lectrical supply must be located in adjacent cabinet within.9 m of opening. Dashed line represents profile of unit. OPNING IDTH CONVCTION STAM OVN 610 Model 562 762 Model 562 wolfappliance.com 27
OLF CONVCTION STAM OVNS Convection Steam Oven FLUSH INST INSTALLATION 25 584 FLUSH INST DPTH FINISHD CLATS* TOP VI 460 FLUSH INST HIGHT** A 8 3 FLUSH INST IDTH** SID VI FRONT VI *ill be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. NOT: lectrical supply must be located in adjacent cabinet within.9 m of opening. Dashed line represents profile of unit. FLUSH INST IDTH CONVCTION STAM OVN A 610 Model 603 21 762 Model 765 102 28 nglish
OLF MICROAV OVNS Microwave Ovens As true cooking instruments, olf microwave ovens have features that make fast meals better meals. New drop down door microwaves feature a door that hinges at the bottom. Drop down door microwaves are designed to match olf transitional, professional and contemporary products. Microwave ovens can be installed in a standard or flush inset application. DROP DON DOOR MICROAVS TRANSITIONAL ICBMDD24T/S/TH ICBMDD30TM/S/TH ICBMDD30T/S/TH PROFSSIONAL ICBMDD30PM/S/PH ICBMDD30P/S/PH CONTMPORARY ICBMDD30CM/B/TH wolfappliance.com 29
OLF MICROAV OVNS Drop Down Door Microwave Ovens TRANSITIONAL 22 538 454 446 IDTH 64 546 BHIND FRAM OPN OVN DOOR 360 IDTH TRANSITIONAL 610 Model 597 762 Model 759 PROFSSIONAL 22 538 454 446 759 83 546 BHIND FRAM OPN OVN DOOR 360 CONTMPORARY 22 538 454 446 759 64 546 BHIND FRAM OPN OVN DOOR 360 30 nglish
OLF MICROAV OVNS Planning Information DROP DON DOOR MICROAV The drop down door microwave oven can be installed in a standard or flush inset application. Finish the edges of the opening. They may be visible when the door is open. For standard installations, face trim will overlap stiles and rails. Refer to the chart below. For flush inset installations, a minimum 3 reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90. INSTALLATION RQUIRMNTS BAS SUPPORT Drop Down Door Microwave MIN 57 kg TRIM OVRLAP 610 MODL 762 MODL Top 5 5 Bottom 0 0 Sides 18 98 lectrical Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply as shown in the illustrations on the following pages. The receptacle may also be located in an adjacent cabinet within reach of the power cord. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recoended and may cause interruption of operation. Refer to the illustration below for minimum power cord plug clearance. LCTRICAL RQUIRMNTS lectrical Supply Maximum Connected Load Receptacle Power Cord 220-240 V AC, 50/60 Hz 900 10A 1.2 m wolfappliance.com 31
OLF MICROAV OVNS Drop Down Door Microwave Oven STANDARD INSTALLATION 548 OPNING DPTH TOP VI 449 OPNING HIGHT OPNING IDTH SID VI FRONT VI NOT: 610 and 762 models require the same opening dimensions. Dashed line represents profile of unit. OPNING IDTH DROP DON DOOR MICROAV 610 Model 562 762 Model 562 32 nglish
OLF MICROAV OVNS Drop Down Door Microwave Oven FLUSH INST INSTALLATION 25 584 FLUSH INST DPTH FINISHD CLATS* TOP VI 460 FLUSH INST HIGHT** A 8 3 FLUSH INST IDTH** SID VI FRONT VI *ill be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. NOT: Dashed line represents profile of unit. FLUSH INST IDTH DROP DON DOOR MICROAV A 610 Model 603 21 762 Model 765 102 wolfappliance.com 33
OLF ARMING DRARS arming Drawers olf warming drawers are designed to take care of prepared foods until it s time to serve them. You can adjust the temperature, keeping moist foods moist and crisp foods crisp. arming drawers are ideal for proofing dough. Drawer fronts are available to match the look of olf ovens and sealed burner rangetops. The integrated drawer front allows for a custom wood panel and handle. ARMING DRAR FRONTS M / SRIS Transitional Professional INTGRATD Contemporary KY FATURS 850-watt heating element with temperature control range of 25 C to 95 C. Spacious 42 L interior capacity. Preset, four-hour automatic shutoff. Hidden electronic touch controls for sleek appearance. Ball-bearing drawer glides for smooth, full extension. Accessory six-piece container set available. Custom Panel 34 nglish
OLF ARMING DRARS arming Drawers DRAR FRONT OPTIONS DIMNSIONS olf warming drawer fronts allow for many design options, but the warming drawer itself will be the same for all applications. A panel mounting kit is required when installing a custom panel. The panel mounting kit is available through an authorized olf dealer. The 51 thick drawer front, in 762 and 914 widths, is designed to be installed below a sealed burner rangetop, so the panel aligns properly with the front of the rangetop. Dimensions for the warming drawer remain the same, even though the drawer front may be wider to match a olf 914 oven or sealed burner rangetop. IDTH 718 264 B A 578 229 OPN DRAR 546 DRAR FRONT MODL 762 Drawer Front 759 914 Drawer Front 911 M SRIS A B Transitional / Professional 22 83 Contemporary 25 86 SRIS A B Transitional / Professional 29 89 Professional (51 thick) 54 114 Contemporary 35 95 INTGRATD DRAR FRONT CUSTOM PANL H D Typical Dimensions 759 264 19 Min Thickness 16 wolfappliance.com 35
OLF ARMING DRARS Planning Information The warming drawer must be installed with a olf drawer front, avail able through an authorized olf dealer. Specific installation instructions are included with the drawer front. The warming drawer can be installed in a standard or flush inset application. For a standard installation, the drawer collar and front panel sit proud of the cabinet face frame. A recessed installation requires the cabinetry be recessed by 5 so the collar is flush with the cabinet face frame but the drawer front will sit proud. A flush inset installation requires the drawer collar and front panel be recessed to be flush with surrounding cabinetry. Refer to illustrations on the following pages for minimum cabinet dimensions for your specific installation. Finish the edges of the opening. They may be visible when the drawer is open. LCTRICAL Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply flush with the back wall and within the shaded area shown in the illustrations on the following pages. For ease of installation, the electrical supply for the warming drawer can be placed in an adjacent cabinet within reach of the power cord. LCTRICAL RQUIRMNTS lectrical Supply Maximum Connected Load Receptacle Power Cord 220-240 V AC, 50/60 Hz 850 10A.9 m For standard installations, face trim will overlap stiles and rails. Refer to the chart below. For flush inset installations, a minimum 3 reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90. INSTALLATION RQUIRMNTS BAS SUPPORT arming Drawer TRIM OVRLAP Top, Bottom and Sides MIN 90 kg 16 36 nglish
OLF ARMING DRARS arming Drawer STANDARD INSTALLATION 584 OPNING DPTH TOP VI ANTI-TIP BLOCK 232 OPNING HIGHT 727 OPNING IDTH SID VI FRONT VI NOT: Location of electrical supply within opening may require additional cabinet depth. wolfappliance.com 37
OLF ARMING DRARS arming Drawer FLUSH INST INSTALLATION A DRAR FRONT DPTH 610 FLUSH INST DPTH FINISHD CLATS* TOP VI ANTI-TIP BLOCK 270 FLUSH INST HIGHT** 19 19 19 765 FLUSH INST IDTH** SID VI FRONT VI *ill be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. NOT: Location of electrical supply within opening may require additional cabinet depth. DRAR FRONT DPTH A M SRIS SRIS Transitional / Professional 22 29 Professional (51 thick) NA 54 Contemporary 25 35 Custom front panel depth is dependent on panel thickness. 38 nglish
olf Products Limited arranty INTRNATIONAL PRODUCTS FOR RSIDNTIAL US ONLY FULL TO YAR ARRANTY For two years from the date of original installation, your olf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided by olf Appliance under the above warranty must be performed by olf factory certified service, unless otherwise specified by olf Appliance, Inc. Service will be provided during normal business hours. LIMITD THIRD THROUGH FIFTH YAR ARRANTY For five years from the date of original installation, olf Appliance will repair or replace the following parts that prove to be defective in materials or workmanship: gas burners (excluding appearance), electric heating elements, blower motors (ventilation hoods), electronic control boards, magnetron tubes and induction generators. The part(s) will be repaired or replaced, free of charge, with the owner paying for all other costs including labor. All service provided by olf Appliance under the above warranty must be performed by olf factory certified service, unless otherwise specified by olf Appliance, Inc. Service will be provided during normal business hours. wolfappliance.com 39
OLF APPLIANC, INC. PO BOX 44848 MADISON, I 53744 USA OLFAPPLIANC.COM INGDG 8/2015