GENERAL SYMBOLS GENERAL PLUMBING NOTES PLUMBING LEGEND ABBREVIATIONS N PLAN OR DETAIL NO SHEET NUMBER KEYED NOTE TO PLAN REVISION NUMBER NORTH ARROW. IN THE PREPARATION OF THESE PLANS, THE ENGINEER HAS USED CERTAIN ABBREVIATIONS, CONVENTIONS, AND SYMBOLS, THE MEANING OF WHICH ARE ILLUSTRATED AND EXPLAINED WITHIN THE LEGEND.. PLANS ARE DIAGRAMMATIC ONLY. THEY ARE INTENDED TO INDICATE CAPACITY, SIZE, LOCATION, DIRECTION AND GENERAL ARRANGEMENT, BUT NOT EXACT DETAILS OF. THE FACT THAT ONLY CERTAIN FEATURES OF THE INSTALLATION ARE INDICATED MUST NOT BE TAKEN TO MEAN THAT OTHER FEATURES WILL NOT BE REQUIRED. 3. COORDINATE WITH THE OTHER TRADES TO ENSURE THAT EACH TRADE SHALL HAVE SUFFICIENT SPACE TO INSTALL THEIR EQUIPMENT (DUCTWORK, PIPING, ELECTRICAL WORK, ETC.). 4. ONCE THE PIPING HAS ENTERED EACH UNIT FROM BELOW THE FLOOR SLAB, PIPING SHALL BE RUN ABOVE THE CEILING IN EACH UNIT UNLESS NOTED OR INDICATED OTHERWISE. 5. VERIFY ALL DIMENSIONS FROM ARCHITECTURAL PLANS AND FIELD DIMENSIONS. 6. ALL RISES AND DROPS IN PIPING ARE NOT NECESSARILY SHOWN. 7. PROVIDE STOP OR ANGLE VALVES ON EACH WATER CONNECTION TO EACH PLUMBING FIXTURE. 8. PROVIDE ALL STRUCTURAL MEMBERS, SPORT BRACKETS, FLASHING, HARDWARE, ETC. REQUIRED TO INSTALL A COMPLETE SYSTEM. 9. PROVIDE CHROME PLATED ESCUTCHEON PLATES AT ALL EXPOSED WALL PENETRATIONS AND CEILING PENETRATIONS. 0. PROVIDE CLEANOUTS ON SANITARY LINES AND CONDENSATE DRAIN LINES AS REQUIRED BY CODE.. PROVIDE ACCESS PANELS FOR ALL SHUT-OFF VALVES LOCATED ABOVE GYPSUM BOARD CEILINGS. COORDINATE WITH GENERAL CONTRACTOR. COLD WATER PIPE HOT WATER PIPE HOT WATER RETURN PIPE EXISTING COLD WATER PIPE EXISTING HOT WATER PIPE EXISTING HOT WATER RETURN PIPE SOIL OR WASTE PIPE EXISTING SOIL OR WASTE PIPE VENT PIPE EXISTING VENT PIPE CHILLED WATER RETURN PIPE CHILLED WATER SPLY PIPE CONDENSER WATER PIPE COOLING WATER RETURN PIPE COOLING WATER SPLY PIPE STORM FIRE TURNED TURNED DOWN A/C AFF AFG BFF BFG BTU CO CONN CW DFU ED EX FU FL FCO GPM GC GCO GW HW HWR IN MIN PC SAN OR S SSD ABOVE CEILING ABOVE FINISHED FLOOR ABOVE FINISHED GRADE BELOW FINISHED FLOOR BELOW FINISHED GRADE BRITISH THERMAL UNIT CLEANOUT CONNECTION COLD WATER DOWN DRAINAGE FIXTURE UNIT EQUIPMENT DRAIN EXISTING FIXTURE UNIT FLOOR FLOOR CLEANOUT GALLONS PER MINUTE GENERAL CONTRACTOR GRADE CLEANOUT GREASE WASTE HOT WATER HOT WATER RETURN INCHES MINIMUM PLUMBING CONTRACTOR SANITARY SECONDARY STORM DRAIN 635 West Trade Street, Suite A Charlotte, North Carolina 86 T:704.374.096 F:704.34.3808 c 07 T&P ED TEE, OUTLET DOWN TEE, OUTLET TEMPERATURE AND PRESSURE RELIEF DRAIN PIPING EMERGENCY DRAIN PAN PIPING SD V VTR WCO W WTR WSFU STORM DRAIN VENT VENT TO ROOF WALL CLEANOUT WASTE WATER WATER SPLY FIXTURE UNIT GATE VALVE W/ WITH PRESSURE RELIEF VALVE W/O WITHOUT BALL VALVE FIXTURE PLUMBING FIXTURE DESIGNATION (UNDER LINED) EXISTING MEDICAL GAS PIPE NATURAL GAS PIPE COMPRESSED AIR PIPE NITROUS OXIDE PIPE NITROGEN PIPE OXYGEN PIPE VACUUM PIPE 6//08 5:: PM C:\RevitLocal06\CLT803 TH-MEP-06_dwolford@mcveighmangum.com.rvt 933 R.G. Skinner Parkway NOTES & LEGENDS 6-006 /9/8 P00
PLUMBING FIXTURE SCHEDULE - TOWNHOME DESIGNATION MANUFACTURER MODEL # FIXTURE DESCRIPTION P- ProFlo STANDARD 6 /" HIGH VITREOUS CHINA WATER CLOSET FLUSH TANK (.6 GPF) SEAT - STANDARD PLASTIC SEAT MOUNT FLUSH CONTROL ON WIDE SIDE OF STALL CONNECTION SCHEDULE WASTE VENT CW HW 3" " /" -- 635 West Trade Street, Suite A Charlotte, North Carolina 86 T:704.374.096 F:704.34.3808 P- KOHLER ARCHER K-355 VITREOUS CHINA UNDER COUNTER-MOUNT LAVATORY FAUCET - PHISTER ARITEK LG49-LPMC POLISHED CHROME TRAP - /4" CAST BRASS WITH C.O. PLUG SPLY - 3/8" ANGLE-TYPE WITH STOPS " /4" /" /" c 07 P-A KOHLER PINOIR K-035-8 VITREOUS CHINA WALL MOUNTED LAVATORY FAUCET - AMERICAN STANDARD 6053.0.5 GPM SENSOR FAUCET TRAP - /4" CAST BRASS WITH C.O. PLUG SPLY - 3/8" ANGLE -TYPE WITH STOPS " /4" /" /" STERLING 7300-0 60"x36"x8" SHOWER W/TILED WALLS BY OTHERS, SEE ARCHITECTURAL DRAWINGS. (SHAW TGL8/TGL84) VALVE/HEAD: PHISTER ARITEK G89-7LPMC POLISHED CHROME PRESSURE BALANCING CYCLING IN-WALL VALVE (SOLD SEPARATELY) ASSEMBLY, MAX FLOW-.0 GPM DRAIN: SIOUX CHIEF 8-00P W/ 4-/4" NICKALOY STRAINER TOP HEAD TO BE MOUNETD AT 7'-" AFF " /" /" /" STANDARD STAINLESS STEEL SINK, DOUBLE BOWL (ADA) FAUCET - PHISTER G-59-PFCC CHROME PULL OUT INTEGRAL SPOUT C STRAINERS - ELKAY LK-35 SPLY - 3/8" ANGLE-TYPE WITH STOPS TRAP - /" CAST BRASS WITH C.O. PLUG " /" /" /" P-4B GE GFC35V GARBAGE DISPOSER, /3 HP, PH, RESIDENTIAL WHEN LOCATED IN AN ISLAND, PNEUMATIC PUSH BUTTON IN COUNTERTOP TO OPERATE DISPOSAL /" /" -- -- P-5 SIOUX CHIEF 696-00MF ICE MAKER BOX W/ WATER HAMMER ARRESTER -- -- /" -- P-6 SIOUX CHIEF 696-303WF WASHING MACHINE BOX WITH /4 TURN VALVES AND WATER HAMMER ARRESTORS " /" /" /" EWH- BRADFORD WHITE RE5OL6 47-GALLON ELECTRIC WATER HEATER (LOWBOY) 4.5 KW, 40--60,.6 AMPS SET WATER TEMP. CONTROL TO 0 F; PROVIDE FF ADAPTER AND CORRUGATED STAINLESS STEEL SPLY LINES WITH DIELETRIC NIPPLES -- -- AAV STUDOR MINI - VENT AIR ADMITTANCE VALVE - /" -- -- -- SA ZURN Z-700 SERIES WATER HAMMER ARRESTOR. SIZE PER P.D.I. WH-0 VERIFY THAT COMPONENT IS ACCESIBLE -- -- -- -- 6//08 5:: PM C:\RevitLocal06\CLT803 TH-MEP-06_dwolford@mcveighmangum.com.rvt WATER METER MASTER METER FLEXIBLE AXIS METER MULTI-JET WATER METER CONFORMING TO STANDARD AWWA C-708 PROVIDE INOVONICS DATA MONITOR FOR REMOTE READING -- -- -- 933 R.G. Skinner Parkway SCHEDULES 6-006 /9/8 P00
CLEANOUT AND ACCESS COVER. TOP OF COVER TO BE FLUSH WITH TOP OF FLOOR UNIONS AT INLET AND OUTLET CONNECTIONS (TYP) EXPANSION TANK EQUAL TO AMTROL /8 BEND NOTE: FLOOR CLEANOUT (FCO CLEANOUT NOT TO BE LOCATED IN CARPETED AREA. BALANCE OF PIPING SAME AS CLEANOUT TO GRADE CLEANOUT AND ACCESS /8 BEND BALANCE OF PIPING SAME AS CLEANOUT TO GRADE WASTE STACK/ STORM LEADER CLEANOUT (VERTICAL) COLD WATER ''DIP'' TUBE WITH HOLE AT THE TOP INSULATED HOT WATER LINE 6" HEAT TRAP WATER HEATER SHUT-OFF VALVE TO BE SAME SIZE AS THE PIPE IT SERVES COLD WATER LINE. SEE DRAWINGS FOR SIZE AND SPECIFICS A.S.M.E. RATED PRESSURE & TEMP RELIEF VALVE 635 West Trade Street, Suite A Charlotte, North Carolina 86 T:704.374.096 F:704.34.3808 BRASS CLEANOUT PLUG WITH COUNTER SUNK HEAD PIPE P&T RELIEF VALVE DWV COPPER FULL SIZE TO OUTSIDE OF c 07 /8 TEE CLEANOUT AND ACCESS WASTE STACK/ STORM LEADER CLEANOUT (HORIZONTAL) FINISHED GRADE 6'' SQUARE CONCRETE PAD TROWEL SMOOTH AND EDGE CONCRETE 4" DEEP WITH WWF REINFORCEMENTS /8 BEND /8 BEND IF CLEANOUT OCCURS AT END OF LINE CLEANOUT TO GRADE (COTG) WASTE LINE; LENGTH TO SUIT WASTE LINE WATER HEATER - SEE FIXTURE SCHEDULE PROVIDE A '' HIGH PLASTIC SAFEPAN FOR ALL WATER HEATERS '' SAFEPAN DRAIN, PIPE TO FLOOR DRAIN WATER HEATER PIPING DETAIL CLEANOUT DETAILS SINK COUNTER STUDOR FLOW P-TRAP SANITARY PIPE FLOOR BALL VALVE WATER METER EQUAL TO BADGER C700 SERIES WITH RTR; RADIO TRANSMITTER BY METER READER SERVICER CONTRACTOR/OWNER 4 WATER METER ASSEMBLY DETAIL NOTES:. THE AIR ADMITTANCE VALVE SHALL BE LOCATED A MINIMUM OF 4" ABOVE THE HORIZONTAL BRANCH DRAIN OR FIXTURE DRAIN BEING VENTED.. ACCESS SHALL BE PROVIDED AT ALL AIR ADMITTANCE VALVES. THE VALVE SHALL BE LOCATED WITHIN A VENTILATED SPACE THAT ALLOWS AIR TO ENTER THE VALVE. 3. THE AIR ADMITTANCE VALVE SHALL BE RATED IN ACCORDANCE WITH THE STANDARD FOR THE SIZE OF THE VENT TO WHICH THE VALVE IS CONNECTED. 6//08 5:: PM C:\RevitLocal06\CLT803 TH-MEP-06_dwolford@mcveighmangum.com.rvt 3 AIR ADMITTANCE VALVE DETAIL 933 R.G. Skinner Parkway DETAILS 6-006 /9/8
635 West Trade Street, Suite A Charlotte, North Carolina 86 T:704.374.096 F:704.34.3808 c 07 KEYNOTES TO PLAN PROVIDE SHUT-OFF VALVE AND WATER METER FOR EACH UNIT. PROVIDE /" HW TO DISHWASHER. PROVIDE TEE ON TAILPIECE OF DRAIN FOR DISWASHER DISCHARGE. 5 TERRACE 59 P-A /" PWDR. 74 P- 3 84 P- /" P- FAMILY 39 WORKSPACE 85 /" CW TO P- 6//08 5:: PM C:\RevitLocal06\CLT803 TH-MEP-06_dwolford@mcveighmangum.com.rvt P- P- 73 68 6 P- P- P- P- STORAGE 64 Room 75 LAUNDRY 7 3 C L/W-THIRD FLOOR PLAN - DOM. WATER P00 SCALE: /4" = '-0" P-6 /" CW/HW TO /" CW/HW TO KITCHEN 4 /" CW/HW TO P- /" CW/HW TO P- /" DINING 40 /" CW/HW TO P- /" CW/HW TO P- /" CW TO P- /" CW/HW TO P-6 /" /" /" " /" /" P-5 /" CW HW C L/W-SECOND FLOOR PLAN - DOM. WATER P00 SCALE: /4" = '-0" P00 SCALE: /4" = '-0" CAR GARAGE 83 /" EWH- /" /" CW HW C L/W-FIRST FLOOR PLAN - DOM. WATER 933 R.G. Skinner Parkway UNIT C FLOOR PLANS 6-006 /9/8 P00
635 West Trade Street, Suite A Charlotte, North Carolina 86 T:704.374.096 F:704.34.3808 c 07 KEYNOTES TO PLAN PROVIDE TEE ON TAILPIECE OF DRAIN FOR DISHWASHER DISCHARGE. 3" SAN 3" SAN 5 " VTR " V TERRACE 59 P-A " V PWDR. 74 P- /4" V 3 84 P- P- /4" V WORKSPACE 85 FAMILY 39 P- P- 73 3" SAN 3" SAN P- 6//08 5::3 PM C:\RevitLocal06\CLT803 TH-MEP-06_dwolford@mcveighmangum.com.rvt P- 68 6 P- P- STORAGE 64 3" WASTE. ROUTE VENT VTR ON TOP. " VTR " VTR 3" WASTE. ROUTE VENT VTR ON TOP. /4" VTR /4" V LAUNDRY 7 3 C L/W-THIRD FLOOR PLAN - SANITARY/VENT P0 SCALE: /4" = '-0" P-6 KITCHEN 4 P-4B AAV 3" SAN DINING 40 " SAN /4" V C L/W-SECOND FLOOR PLAN - SANITARY/VENT P0 SCALE: /4" = '-0" CAR GARAGE 83 " SAN TO HD EWH- C L/W-FIRST FLOOR PLAN - SANITARY/VENT P0 SCALE: /4" = '-0" 933 R.G. Skinner Parkway UNIT C FLOOR PLANS 6-006 /9/8 P0