Double Skin Air Handling Units

Similar documents
Double Skin Air Handling Units

Double Skin Air Handling Units

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Indoor Air Quality. For assured. Double Skin Air Handling Units

Double Skin Casing Air Handling Units

Centeral Station Air Handling Unit

Air Handling Units. Real HVACR people who understand your needs.

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

AIR HANDLING UNIT AWAL GULF AIR CONDITIONING & REFRIGERATION PVT. LTD.

39G Air Handling Unit

AIR HANDLING UNITS. Revision AG 16-07

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

The ultimate in air handling units: directly and indirectly fired

GUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Classic Series AIR HANDLING UNIT. Range 1000 CFM to CFM 472 L/s to 9440 L/s

The ultimate in air handling units: directly and indirectly fired

Modular Air Handling Unit

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

The ultimate in air handling units: directly and indirectly fired

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

Vision and Skyline Semi-custom Air Handlers

MODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

39HQM Central Station Air Handling Units AiroVison Guide Specifications

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

TYPICAL CPA SPECIFICATIONS

The ultimate in air handling units: directly and indirectly fired

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

AFD Industrial Dehumidifier Series

Centrifugal Fans, Non-Overloading, Backward Inclined

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

LTV - LTV-N Air Handling Unit

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

VENTLESS DOOR-TYPE DISHWASHER

Enjoy the Delighting Comfort Brought by High Air Quality

KOMFORT EC DB Suspended heat recovery air handling units

EHH SERIES DRAW THROUGH FAN COILS CFM

Series 2 FS 100 HM Q S AH D on innovative. a full green. meeting. line features. Page No Introduction a high unit is. Air Handling Units

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

1.1 This section applies to air handling units for HVAC Systems.

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Energy Recovery with Cooling and Heating

Submittal Data Performance Data Electrical Data

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

13 HYGENIC AIR HANDLING UNITS

DUST COLLECTORS & DOWNDRAFT TABLES. A division of BLOWERS

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

An ISO 9001 : 2008 Certified Company SUBURBAN INDUSTRIAL WORKS (LESSEE)

ALL PRODUCTS BROCHURE

The ultimate fresh air solution.

FAN COIL UNITS. The optimal solution for limited space

CU AIR CONDITIONING INDUSTRIES L.L.C

Trane Performance Climate Changer Air Handlers. An air handler for every need.

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

Easdale International INFINITY

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Air Handling Units. Ranging from 15 to 2,000+ tons and 500 to 400,000+ CFM

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

AFD DEHUMIDIFIER SERIES

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

Commercial Evaporative Cooling

A. This Section includes air-handling units with coils for indoor installations.

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

the Innovative Solutions

... DF / IDF Gas fired combined heating and ventilation ...

PROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

Shading Tension Systems

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

SECTION AIR HANDLING UNIT

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

R22 AIR COOLED HIGH STATIC DUCTED SPLIT SYSTEM. Single & Double Skin Evaporator Units. Cooling Capacity : 80 to 750 MBH

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

The Role of Air Handling Units in Combating the Spread of Infectious Disease

DIVISION 15 MECHANICAL

AIR HANDLING UNITS MANDÍK

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Manufacturer of HVAC Equipment Since ,000 sq. ft. on 16 acres. Colton, California USA

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Pharmaceutical Facility Design

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

R. K. Engg. Works Private Limited

Trane Performance Climate Changer Air Handlers. An air handler for every need.

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

Transcription:

Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality

Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering Expert cooling solutions for a wide range of corporate and commercial applications. With this expertise and following the success of standard series of screwless air handling units, Blue Star introduces Engineered Double Skin Air Handling Units in screwless construction. These units are designed to offer customised solutions to suit individual requirements. The units are reliable, long-lasting and assure high indoor air quality. Features such as screwless and sturdy construction, low noise and compact size make these units an ideal choice for a large number of applications. DIDW Centrifugal Forward Curved Fan Copper Tubes Flexible Canvas Connection Base Frame Ultraviolet Light

Bag Filter Sandtrap Louvers Aluminium Anodized Frame Pre Filter Anti-Corrosive Hydrophilic Coated Fins

Enhancing Indoor Air Quality Blue Star has incorporated several advanced features in these air handling units. These features are optional and contribute to a great extent in enhancing the indoor air quality. Screwless Construction: Screwless design allows easy inspection, cleaning and maintenance of the smooth inner surface, thereby reducing the risk of dirt and bacteria accumulation. Moreover, there is no erosion of internal insulation material that contaminates the air stream. Horizontal DSAHU Ceiling Suspended DSAHU Vertical DSAHU The panel frame arrangement has been improved by overlapping the wedge and the special gasket. This arrangement, along with the modified filter frame design minimises the chance of air leakage. It also makes the air handling units ideal for clean room and pharmaceutical applications. Internal sheet metal, filter and coil frame can also be offered in optional Stainless Steel construction for these applications. Efficient Filters: Apart from standard EU-3 type pre-filter, various types of filters such as bag and fine HEPA Filters with different levels of filtration can be selected. These filters are of progressive density type with high dust holding capacity and with lesser pressure drop, ensuring high energy efficiency. UVC Emitters: The option of UVC Emitters inside the units is available to combat the growth of microorganisms. UVC Emitters ensure clean and sterile air at all times. Moreover, the system functions efficiently, resulting in optimum power consumption. Low Leak Dampers: Powder-coated galvanized or aluminium volume control dampers of opposed blades and in aerofoil design are provided to maintain the fresh-air to return-air ratio. A wide range of control options are available that include motorised and manual operation of the damper. The option of sandtrap louvers is also available for outdoor applications preventing sand or dust particles from entering the air handling unit.

Maximising Energy Efficiency With rising costs of electricity, it has become imperative to opt for additional components which keep operation costs under control. The following components also qualify the AHUs for green building applications: Heat Recovery Wheels: Current energy performance guidelines emphasise the usage of heat recovery wheels. These units utilise the energy from stale air to pre-cool the air entering the AHU. Heat recovery wheels used in air handling units recover up to 80% energy, thereby substantially reducing the operating costs. Heat Pipes: Heat pipes are used to transfer the available heat thereby reducing energy consumption and moisture content. Wrap-around heat pipes are used for pre-cooling and reheating the air, whereas heat recovery heat pipes are used for recovering the energy from exhaust air. Variable Frequency Drives: Blue Star offers Variable Frequency Drives specially customised for HVAC applications. These drives offer advanced variable speed technology which helps reduce energy consumption substantially. In new installations, a payback time of less than a year can be achieved when compared to constant volume systems. Energy Efficient Motors: Motors account for nearly two thirds of the power consumption in an HVAC application. Even the smallest improvement in motor efficiency can significantly reduce energy consumption. Blue Star offers EEF1 motors meant for continuous operation. These motors make the AHUs highly energy efficient. Energy Efficient Blowers: Energy efficient DIDW blowers have been incorporated. These are available in three types: centrifugal forward curved, backward curved or backward with aerofoil design. The option of plug fan without the belt and pulleys makes it suitable for clean room and pharmaceutical applications.

A Wide Range of Air Handling Units to Choose From Blue Star offers a wide range of AHUs to suit individual requirements. Standard Air Handling Units Ceiling suspended ranging from 1670 to 13500 CMH (available in 3 direct-driven and 15 belt-driven models) Vertical floor mounted ranging from 3500 to 25000 CMH (available in 10 models) Horizontal floor mounted ranging from 3500 to 60000 CMH (available in 37 models) Engineered Air Handling Units Available from 3500 to 60000 CMH Optimum Selection Blue Star has designed its own AHU selection software which is used by field engineers and is integrated in the manufacturing process. This helps in addressing customer requirements effectively.

Standard Superior Features of the Unit Casing The AHU is constructed on a thick fabricated GSS channel Fan and motor is mounted on a fabricated slide rail. A specially designed motor mounting base plate allows adjustment of the belt tension without disturbing motor alignment. Flexible fire retardant canvas connection is provided at the fan outlet. The coil is placed on sliding channels for ease of service and maintenance The drain pan is made up of Stainless Steel and insulated with a closed cell elastomeric insulation to avoid surface condensation Hinges and Handles The fan section is provided with an access door for ease of serviceability of the fan and motor User-friendly nylon handles can be operated from both inside and outside the casing View Port and Marine Lamp View port is provided on the fan door panel to enable monitoring the fan and motor status Marine lamp provides easy visibility Fans Centrifugal fans are of double inlet, double width type with forward curved impeller. Fans are AMCA certified for sound and air performance, and are statically and dynamically balanced. The whole fan assembly is trim balanced to match ISO 1940 & AMCA 204.G 2.5 standards. The motor is of TEFC squirrel cage induction type with IP55 protection and Class F insulation. Limit Switch Door limit switch automatically trips the motor/fan when the door is opened.

ACPD-AUG 09 981242