AIR HANDLING UNITS. Revision AG 16-07

Similar documents
CENTRAL SPLIT UNIT UNIC

AIR COOLED PACKAGED CHILLER

AIR HANDLER SPECIFICATION

Centeral Station Air Handling Unit

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Modular Air Handling Unit

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Double Skin Casing Air Handling Units

1.1 This section applies to air handling units for HVAC Systems.

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

SECTION AIR HANDLING UNIT

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

MODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC

39G Air Handling Unit

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

Double Skin Air Handling Units

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Double Skin Air Handling Units

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

SECTION AIR COILS

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

TYPICAL CPA SPECIFICATIONS

SECTION AIR COILS

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

ENGINEERING & SERVICE

DIVISION 15 MECHANICAL

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

Indoor Air Quality. For assured. Double Skin Air Handling Units

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

COMMERCIAL AIR CONDITIONERS. Air Handling Unit & Modular Air Handling Unit

DARTMOUTH COLLEGE DESIGN March 15, 2003 & CONSTRUCTION GUIDELINES

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

SECTION WATER-SOURCE UNITARY HEAT PUMPS

CWA4 Chilled & Hot Water Fan Coil

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.

MACH N-407 Heat Pump Air-Cooled Chiller

The ultimate in air handling units: directly and indirectly fired

EHH SERIES DRAW THROUGH FAN COILS CFM

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

R22 AIR COOLED HIGH STATIC DUCTED SPLIT SYSTEM. Single & Double Skin Evaporator Units. Cooling Capacity : 80 to 750 MBH

AIR HANDLING UNIT AWAL GULF AIR CONDITIONING & REFRIGERATION PVT. LTD.

Submittal Data Performance Data Electrical Data

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

From 230 tons to. Water-Source Heat Pump Products. Premium Performance Environmentally Friendly Superior Construction

Series 2 FS 100 HM Q S AH D on innovative. a full green. meeting. line features. Page No Introduction a high unit is. Air Handling Units

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Modular Supply Make-Up Air Unit

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

The ultimate in air handling units: directly and indirectly fired

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

The ultimate in air handling units: directly and indirectly fired

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

39HQM Central Station Air Handling Units AiroVison Guide Specifications

The ultimate in air handling units: directly and indirectly fired

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Direct Fired Heater Model AD Specification

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Enjoy the Delighting Comfort Brought by High Air Quality

50TM TFF COMBINATION HEATING/COOLING UNITS

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

FCC Fan-Coil Units High-Performance, Vertical

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

50TM COMBINATION HEATING/COOLING UNITS

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Modular Heating & Ventilating Unit Model IGX-HV

Transcription:

AIR HANDLING UNITS UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products and facility. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be described herein. Please contact our customer department for specific information on the current design. Consultancy & Design Our Engineering Dep t is always available to solve special requirements, investigating the client situation and using the most sophisticated available tools. The knowledge and the precious experience of our Engineers is supported by the most advanced computerized calculations and design programs. Revision AG 16-07

COOLER Air Handling Units CAHU are constructed of double skin panels. Casing shall have perimeter modular frame. Removal of the side panels shall not affect the structural integrity of the unit. The frame work shall be made from non-corrosive extruded aluminum or galvanized steel channels fitted together with PVC or aluminum corners. The floor panels shall have double construction to allow maintenance personal access without damages to the insulation. The whole unit shall be mounted on heavy gauge galvanized steel base frame for easy shipment and handling. The minimum height of the base shall be 100 mm and designed to insure air circulation and avoid entrapment of moisture below the unit. The base frame is to be used in lieu of concrete plinths or other additional bases that are used in site. Units shall have sloped drain pan with a bottom connection to eliminate stagnation of condensate. Drain pan shall be at least 1.25mm thick galvanized steel painted with mastic compound for corrosion protection. Panels shall be 25 mm to 50 mm thick sandwich type with injected polyurethane foam, or neoprene coated fiberglass insulation, for a rigid non-vibrating construction. The insulation shall not absorb moisture and it is rustresistant. The panel insulation shall have a maximum heat transfer "K" value of 0.017 W/m/ C (0.118 BTU/in/ft2/h/ F) to prevent condensation from occurrig. The panels shall held in place by "rapid access" clips and locks arrangement for easy removal. The panels shall be flash mounted. There shall be no sharp edges or corners on the unit which might cause accidents or injury. Sealing shall be achieved by means of a non-hygroscopic seal compressed between the panel and the aluminum frame channels to prevent cold tracking and air leakage between the panels and the frame. The outer wall shall be 1 mm galvanized steel, chemically treated, precoated with primer and plastic topcoat to resist nicks and scratches to galvanized panels and to allow easy cleaning of exterior. The coating shall be weather resistant. The inner wall shall be 0.8 mm galvanized steel. COOLER CAHU Models: Standard Sizes from 1,000 to 90,000 m3/h Air-Flow All Sizes availables to fit all Client s needs even with the AHU directly assembled on Client concrete walls structures From simple Ventilation to the most sophisticated Pharmaceutical, Laboratory or Hospital applications All CAHU shall have cooling and heating by Cold & Hot Water or DX by the New ECO-Ozone-Friendly Freons FAN SECTION Each model can be supplied with various size of fans to insure best fan selection. All fans are double inlet centrifugal fans with casing, statically and dynamically balanced and available with forvard curved, backward curved and aerofoil section V blades. Fans are mounted on rubber-in-shear anti vibration isolators (spring isolators are available) and have flexible canvas connector between fan outlet and unit casing. Motors are installed with belt drive on an adjustable base and are available for any voltage.

Motors shall be totally enclosed with IP54 protection with class F insulation and suitable for operation at ambient temperature 54 C. COIL SECTION Coils are mounted on guide rails for easy side removal. Coil face velocity shall not exceed what is specified on the coil schedule. The number of fins provided should be the minimum needed to meet the performance required to minimize the pressure drop across the coil. Coil shall be seamless copper tube mechanically expended into aluminum plate fins. Coils shall be proof tested at 28 bar (400 psig) and leak tested 17 bar (250 psig). Coils performance shall be rated in accordance with ARI Standard 410. Coil seamless copper tube, mechanically expended into copper plate fins. (Option) Coil seamless copper tube, mechanically expanded into anti-corrosive plastic coated aluminum plate fins. (Option) FILTER SECTION The filter section shall be provided by the air handling unit manufacturer with the same casing construction as the unit. Following filter sections are available: - Bag filters. - Low and high velocity cleanable plastic or metallic and - Absolute filters. throw away filters. - Carbon filters. - Autoroll filters. - Inertia filters complete with bleed fan. - Automatic oil bath filters. Filter frames or slide are used, they have channels and slide rails, sideremovables, for service & replacement.

HUMIDIFIER SECTION Various types are available: - Mat type. - Steam, utilizing steam pipe. - Water spray type. - Pan type. - Electrode steam boiler. MIXING-BOX & DAMPER SECTION Mixing box and damper. The mixing box shall be provided by the air handling units manufacturer with the same casing construction as modulate the volume of outside return air. Dampers shall be opposite blade type fitted into a casing of galvanized steel sheet if galvanized steel blades, or in aluminum casing with aluminum blades. The maximum face velocity throw the dampers shall not exced 5m/s up to minimize pressure drop and generated noise across the dampers. SPECIAL SECTIONS Air-washers section (various efficiencies), heat-recovery units, silencer, electric-heater, sand-trap-iouvers, inertial-filters, external flexible connectors, inlet guide vanes and moisture-eliminator, are available. 24 VAC transformer ready to connect electronic thermostat (optional).

QUALITY GUARANTE UNIC sal COOLER guarantees contractual free maintenance, availability of all parts and components, and qualified field technicians to carry out the maintenance requirements. UNIC sal Company is ISO 9001:2015, DQS-UL, IQNet and CE Certified. UNIC sal Roumieh (Industrial area) Beirut Tel: +961.1.890111-222 1.884579 1.878853 3.236936 Fax : +961.1.878854 P.O.Box 90.1701 Beirut, LEBANON unic@unic-cooler.com - www.unic-cooler.com