DOMEKT. Heat Recovery Air Handling Units

Similar documents
Heat Recovery Air Handling Units

DOMEKT. Residential ventilation units

DOMEKT. Residential ventilation air handling units

KOMPAKT. Air Handling Units

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe

VERSO Air Handling Units

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

VERSO DOMEKT. Residential ventilation units m³/h. Commercial ventilation units m³/h

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Domekt R. Air handling units with a rotary heat exchanger. Operating capacity ranges from 50 to 950 m 3 /h. Advantages of Domekt R units

DOMEKT Residential ventilation units

Page 2 of 16. DOMEKT price-list PRICE-LIST Prices in POUND STERLING excluding VAT. Prices are valid for year 2018.

17 Domekt R. Units with a rotary heat exchanger. Domekt RHP Units with a rotary heat exchanger and an integrated heat pump.

VERSO Air Handling Units

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

AHU N : Range: VERSO VERSO. Air handling units. Plug & Play Energy Saving Smart Design Reliable & Safe

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

Energy efficient ventilation equipment

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

VR 400/700 DCV/DC. Good ventilation For dwellings, smaller offices and business premises. com

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

VERSO. Commercial ventilation units 01/03/ Tél

KOMFORT EC DB Suspended heat recovery air handling units

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Elektros montavimo ir eksploatavimo instrukcija 2 Electrical installation and Operation Manual 18 Инструкция по электромонтажу и эксплуатации 34

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

Home Solutions for Residential Ventilation

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

Flexit air handling units UNI 2, 3 og 4

Specification data Topvex. Rotating or Cross flow heat exchanger.

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

Flexit air handling units C2 and UNI 2, 3,4

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

Heat recovery unit RDKS

CONTENT: VEX308 Decentralised ventilation VEX308

Energy efficient ventilation equipment

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual

Healthy, comfortable and energy-efficient ventilation

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

Healthy, comfortable and energy-efficient ventilation

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

TSEK VHR EC HEAT RECOVERY UNITS

VALLOX VENTILATION PRICELIST 2018

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

SINGLE-ROOM VENTILATION. for schools and public spaces

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING.

Controlled mechanical ventilation GB 03

AIR HANDLING UNITS ver B

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

... RTU. Packaged Air to Air Heat Pump...

2013 innovation. Room-by-room demand controlled heat recovery ventilation

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION

Breathe Fresh Air at Home

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

Smart air handling unit for swimming pools IN CONFORMITY WITH THE REQUIREMENTS OF

TopMaster Air Handling unit. Technical data

Technical Information HXV - HRV Ventilation

Series VENTS VUT R WH ЕС

Heat Recovery Unit HERU. web-version

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

VEX100 series Air handling units with cross-flow heat exchanger

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

COMPACT VENTILATION UNITS DUPLEX EC5

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

AIR HANDLING UNITS. AmberAir Compact Smarty RIS EKO 3.0 RIRS EKO 3.0

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

Domestic & Commercial Fans

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

Plus Perimeter Aspiration Timer Remote control predisposition

TECHNICAL SPECIFICATION

Refrigerated Air Dryers

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

RHC GAS FIRED HEATING COILS

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

HCV 4 - HCV 5 - HCH 5 - HCH 8

Transcription:

Heat Recovery ir Handling Units OMKT

Heat Recovery ir Handling Units OMKT

KOMFOVNT OMKT air handling units Komfovent air handling units are made to create healthy indoor climate and ensure efficient energy saving. Products are designed and produced in conformance with high quality and performance requirements. ll components and parts of the units are accurately selected and assembled to achieve the best results in operation. Reliability of the products is based on the deep attention to the details. Your family health protection Units efficiently clean the air from the particulates, allergens, dust and maintain healthy indoor climate. Reliable and durable ouble quality control system. ir handling units efficiency is measured in a new modern laboratory. Units are tested in the independent laboratories in Switzerland and Germany. ouble anticorrosive units casing protection. Wide range of air handling units We are offering an extremely wide range of air handling units in order to fulfil our customers needs. nergy efficient Silent operation. Reduces expenses for heating, saves electric energy. Thermal efficiency and energy saving of the heat exchangers of KOMFOVNT air handling units are up to 9%. Highly efficient (electronically commutated) fans use 0% less energy than (alternating current) fans with voltage control. The special control system designed by our qualified engineers contributes to saving energy. User friendly control system Modern and attractive control panels enable a customer to select the desirable functions, set and change parameters as well as observe the ventilation processes on L screen. KOMFOVNT OMKT air handling units are intended for residential premise ventilation within 0 m to 0 m. Two functions in one unit:. Ventilates premise: ensures balanced ventilation with heat recovery supplying fresh air and extracting the used one.. Possibility to connect a kitchen hood or any other extraction device. ir handling units with integrated automatic control are fully prepared for installation: just PLUG & PLY. wide range and extremely compact size of the units allow the customer to mount them not only in the new premise but also in the renovated ones.

Quick KOMFOVNT OMKT unit selection OMKT RGO air handling units with rotary heat exchanger 00V/VW* Vertical 00V/VW* Vertical 0V- Vertical Passive House 0P/PW* Suspended 00P/PW* Suspended 600H/HW* Horizontal Residential area m ~0 ~60 ~80 ~0 ~00 ~0 Supply and exhaust m /h 0 00 67-08 0 0 600 air flow under pressure Pa 00 00 9-69 00 00 00 Thermal efficiency of rotary heat exchanger % 80 8 78 7 79 79 fan type OMKT RU air handling units with plate heat exchanger 00V/VW* Vertical 00V/VW* Vertical Passive House 0V/VW* Vertical 00P/PW* Suspended Residential area m ~0 ~80 ~80 ~0 Supply and exhaust m /h 00 9-6 0 670 air flow under pressure Pa 00 9-69 00 00 Thermal efficiency of plate heat exchanger % 79 76 7 86 fan type Notes: electrical heater, W hot water heater * uct mounted water air heater must be ordered additionally to be installed in the duct. Precise selection quipment is selected by helpful and informative software, available to be downloaded to your P from our website: www.komfovent.com Technical data sheets present important technical parameters in desired working point of the selected unit: efficiency, SFP, acoustics and other required data.

n :.09.00 Range: ROTOR Heat exchangers in KOMFOVNT air handling units Rotary heat exchanger 6,8,0 +,0 +,6 TST IN GRMNY n SWITZRLN The operating principle of the RGO air handling units with nonfreezing rotary heat exchanger Rotary heat exchangers work on the principle of heat recovery: rotating aluminium drum absorbs heat of the exhaust air and warms up the air supplied to the ventilated room. dvantages of the rotary heat exchanger: rotary heat exchanger allows to reduce energy consumption for warming up the supply air by approximately times, compact, non freezing in comparison with the cross flow plate heat exchangers, a share of the exhaust air moisture is transferred to the air supplied to the ventilated room, cools down the supply air in summer in a conditioned space, no need in drainage. ouble plate heat exchanger,0,8 +,0 +8, The operating principle of the RU air handling unit with cross flow plate heat exchanger The heat of the exhaust air is transferred to the supply air through aluminium plates of the heat exchanger. ir flows through the heat exchanger crosswise. Unit design prevents penetration of the exhaust air to the fresh air flow. ounterflow polystyrene plate heat exchanger,0 6,6 +9,8 + dvantages of the plate heat exchanger: in the process of ventilation the heat of the exhaust air is recovered to the supplied air, totally separated air flows, special solution of using double plate heat exchangers reduces the risk of frosting, defrosting process is controlled by automatics. ounterflow aluminium plate heat exchanger 6,6,0 +9,8 + Intermediate moisture removal not: thermal efficiency indicated for wet conditions. for dry conditions efficiency refer to the selection software.

Vertical unit OMKT RGO 00V Unit is specially designed to be integrated into the kitchen furniture over the cooker. Its extremely compact size gives us a perfect possibility of simple mounting in a new flat, renovated premise, etc. Unit is applicable to ventilate the premise up to 0 m. ir handling unit is fully prepared for exploitation. Integrated automatic control with the wall mounted panel which is handy and simple in use ensures the most economic unit functioning and necessary control. Unit RGO 00V performs two functions:. Ventilates premise: ensures balanced ventilation with heat recovery supplying fresh air and extracting the used one,. xtracts the used air through kitchen hood: during cooking a user switches on the hood and the air is extracted through the hood by the unit. Kitchen hood has a specially designed damper inside. The air flow through the hood is adjusted with it. not: There is no danger of rotary wheel greasing because air flows are not mixing in the unit when you are cooking! WHY? ecause when you are cooking you switch on a cooker hood and it opens an internal by-pass damper by this action. Used air from cooking and fumes is extracted by exhaust fan and directed to the by-pass, without getting into rotor. xtract air fan can be easily taken out for cleaning when it is needed. Operation principle: When kitchen hood is switched On When kitchen hood is switched Off xtract through kitchen hood

Vertical units OMKT RGO 00V Highly efficient rotary heat exchanger recovers up to 89% of heat. RGO 00V special design has a big advantage: user does not need to specify unit s inspection side. This unit is both right- and left- hand in one. front and back covering panels are easi ly removable this way, when installing it, the unit must be only turned around to get the required inspection side and ducts connection. Integrated automatic control with the wall mounted touch sensitive panel which is handy and simple in operation ensures the most economic unit functioning and necessary control. RGO 00V Shown as left 6 for some units right and left sides are mirrored, but in some units are rotated. hoose the right side of unit installation. 660 6 Shown as right 7 (x) f xplication 0 6 9 60 8 8 f 00 600 Rotary heat exchanger lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 utomation control system dditional extraction connection (by pass extraction without heat recovery) Kitchen hood connection f (by pass extraction without heat recovery) 6

Technical information RGO 00V RGO 00VW* Supply voltage, V/Hz ~0 / 0 / phase Maximal operating current,.0 0.76 Input fans power, W x 70 Heater capacity, kw 0.8. Unit size (height x width x depth), mm 6 x 600 x 0 uctwork connection, mm x filter for supply/exhaust air, mm 8 x 0 x 6-f7 Unit weight, kg Unit color RL 900 * for more detailed information look at the hot water duct air heater H specification. Static pressure (Pa) RGO 00V performances ir volume flowrate (m /s) 0 0,0 0,0 0,06 0,08 00 0 SFP 00 SFP 0,7 0 00 SFP 0, 0 Temperature efficiency η t (%) 9 90 8 80 7 Temperature efficiency % 70 0 00 0 00 0 00 pplication: RH 8% outdoor RH % indoor kw ir volume flowrate (m /h),,, nergy recovery (kw) 0 0 0 00 0 00 0 00 0 ir volume flowrate (m /h) P[kW] = SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter f7. To calculate the power consumption for fan use formula: P = SFP V; where SFP kw (m s) and V m s. RGO 00V acoustic data -weighted sound power levels L w, d(). Operation point: 0 m /h (9 l/s), 00 Pa. Octave band mid-frequency, Hz dditional inlet Kitchen hood inlet asing 6 0 00 000 000 000 8000 Total 6 8 8 9 9,0 9 6 60 8 6 9 6,7 6 8 8 0 9, 9 6 60 8 6 9 6,7 6 7 60, 6 7 60, 0 8 8, The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings 0 0 7 7,7 7

Vertical units OMKT RGO 00V xtremely compact unit in size and high energy efficient. Highly efficient rotary heat exchanger recovers up to 90% of heat. Unit compact size and high efficiency offer the best choice to ensure healthy microclimate in your apartments or small houses. Unit is applicable to ventilate the premise up to 60 m. Unit is designed to ensure ventilation in the premise and may be connected with a kitchen hood via an additional duct. ny exhaust air diffuser may be connected instead of a kitchen hood to by pass duct connection (to extract air from bathroom, laundry, etc.). Integrated automatic control with the wall mounted touch sensitive panel, which is handy and simple in operation ensures the most economic unit functioning and necessary control. RGO 00V Shown as left 7 6 Shown as right 9 6 7 00 0 90 600 xplication Rotary heat exchanger lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 utomation control system dditional extraction connection (by pass extraction without heat recovery) 8

Technical information RGO 00V RGO 00VW* Supply voltage, V/Hz ~0 / 0 / phase Maximal operating current,. 0.76 Input fans power, W x 70 Heater capacity, kw.0. Unit size (height x width x depth), mm uctwork connection, mm filter for supply/exhaust air, mm Unit weight, kg Unit color 7 x 600 x 9 x 60, x 0 x 0 x 6-f7 RL 900 * for more detailed information look at the hot water duct air heater H specification. Static pressure (Pa) RGO 00V performances ir volume flowrate (m /s) 0 0,0 0,0 0,06 0,08 00 SFP 0,7 0 SFP 0, 00 0 SFP 0, 00 SFP 0, 0 Temperature efficiency η t (%) 9 90 88 86 8 Temperature efficiency % kw 8 0 0 00 0 00 0 00 pplication: RH 8% outdoor RH % indoor ir volume flowrate (m /h) nergy recovery (kw) 0 0 0 00 0 00 0 00 0 P[kW]= SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter F7. note: characteristics explanation is available on the page 7. ir volume flowrate (m /h) RGO 00V acoustic data -weighted sound power levels L w, d(). Operation point: 0 m /h (8 l/s), 00 Pa. Octave band mid-frequency, Hz dditional inlet asing 6 0 00 000 000 000 8000 Total 9 9 0 9,8 9 9 6 60 6 7 66,6 9 9 9,8 9 9 6 60 6 7 66,6 8 6 6 6 6, 6 6 0 8 6 6 8, The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings 8 8 7 6 7 6 8, 9

Vertical units OMKT RGO 0V- xtremely compact unit in size and high energy efficient Highly efficient rotary heat exchanger recovers up to 8% of heat. Unit compact size and high efficiency offer the best choice to ensure healthy microclimate in your apartments or small houses. Unit is applicable to ventilate the premise up to 80 m. Unit is designed to ensure ventilation in the premise and may be connected with a kitchen hood via an additional duct. ny exhaust air diffuser may be connected instead of a kitchen hood to by pass duct connection (to extract air from bathroom, laundry, etc.). Integrated automatic control with the wall mounted touch sensitive panel which is handy and simple in operation ensures the most economic unit functioning and necessary control. RGO 0V- Shown as left 7 6 Shown as right 60 0 60 0 60 0 680 xplication Rotary heat exchanger lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 utomation control system dditional extraction connection (by pass extraction without heat recovery) 0

Technical information Supply voltage, V/Hz Maximal operating current, Input fans power, W Heater capacity, kw nergy recovery of rotary heat exchanger up to, kw Unit size (height x width x depth), mm uctwork connection, mm filter for supply/exhaust air, mm Unit weight, kg Unit color RGO 0V ~0 / 0 / phase. x.0 ~. 60 x 680 x x 60, x 70 x 0 x 6-f7 6 RL 900 RGO 0V performances Temperature efficiency ir volume flowrate (m /s) Static pressure (Pa) 0 0,0 0,06 0,09 0, 00 SFP, 0 00 SFP 0 SFP 0,7 00 0 SFP 0, 00 0 Temperature efficiency η t (%) 8 8 8 8 8 % 80 00 0 00 0 00 0 00 pplication: RH 8% outdoor RH % indoor kw ir volume flowrate (m /h) 6 nergy recovery (kw) 0 0 00 00 00 00 00 P[kW]= SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter F7. note: characteristics explanation is available on the page 7. ir volume flowrate (m /h) RGO 0V acoustic data -weighted sound power levels L w, d(). Operation point: m /h (88 l/s), 00 Pa. Octave band mid-frequency, Hz dditional inlet asing 6 0 00 000 000 000 8000 Total 9 7 6 7 6, 7 8 6 6 6 60 6 69, 9 7 6 8 6 6,6 7 8 6 6 6 60 6 69, 8 7 8 60 6, 9 9 8 9,7 The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings 8 8,8

False-ceiling units OMKT RGO 0P Unit s height is only 0 mm so it can be easily mounted in any convenient place. Rotary heat exchanger ensures high heat recovery and thermal efficiency up to 87%. Special unit s design with extremely low height allows us to mount it horizontally, hiding by false-ceiling or vertically near the wall. Unit RGO 0P may ventilate premise up to 0 m. It is intended for ventilation of flats, apartments, small houses, as well as classrooms, small offices and conference rooms. Integrated automatic control with the wall mounted touch sensitive panel which is handy and simple in operation ensures the most economic unit functioning and necessary control. RGO 0P Shown as right 0 6 7 80 0 0 7 60(x) 7 0 790 0 80 0 Shown as left xplication Rotary heat exchanger lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 utomation control system dditional extraction connection (by pass extraction without heat recovery)

Technical information RGO 0P RGO 0PW* Supply voltage, V/Hz ~0 / 0 / phase Maximal operating current,.70.6 Input fans power, W Heater capacity, kw Unit size (height x width x depth), mm uctwork connection, mm filter for supply/exhaust air, mm Unit weight, kg Unit color x 0.0 0 x 0 x 790 x 60, x 78 x 8 x 6-f7 RL 900 * for more detailed information look at the hot water duct air heater H specification. Static pressure (Pa) RGO 0P performances ir volume flowrate (m /s) 0 0,0 0,0 0,06 0,08 0 SFP, 00 0 SFP 00 SFP 0,7 0 Temperature efficiency η t (%) 90 88 86 8 8 80 78 76 7 Temperature efficiency % 7 0, 0 00 0 00 0 00 pplication: RH 8% outdoor RH % indoor kw ir volume flowrate (m /h),,,, nergy recovery (kw) SFP 0, 0 0 0 00 0 00 0 00 P[kW]= SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter F7. note: characteristics explanation is available on the page 7. ir volume flowrate (m /h) RGO 0P acoustic data -weighted sound power levels L w, d(). Operation point: 7 m /h (9 l/s), 00 Pa. Octave band mid-frequency, Hz dditional inlet asing 6 0 00 000 000 000 8000 Total 7 6 9 6,8 6 9 6 6 6 6 6 9 68,8 7 6 9 6,8 6 9 6 6 6 6 6 68,8 7 8 6 6 6,9 7 9 9 8 8 6, The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings 9 6 7 8 9,

False-ceiling units OMKT RGO 00P Unit s height is only 0 mm. High thermal efficiency is reaching up to 88% because of two rotors used in the unit. Unit RGO 00P is applicable for the ventilation of premise up to 80 m area. It is intended for ventilation of apartments, small houses, conference rooms. In spite of low unit s height, thermal efficiency in RGO 00P reaches up to 88% because of two rotors used in the unit. y-pass or any other exhaust air diffuser may be connected instead of a kitchen hood to by pass duct connection (to extract air from bathroom, laundry, etc.). Integrated automatic control with the wall mounted touch sensitive panel which is handy and simple in operation ensures the most economic unit functioning and necessary control. RGO 00P Shown as right 0 6 0 00 00 0 00(x) 0 00 60 0 0 60 0 7 Shown as left xplication Rotary heat exchanger lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 utomation control system dditional extraction connection (by pass extraction without heat recovery)

Technical information RGO 00P RGO 00PW* Supply voltage, V/Hz ~0 / 0 / phase Maximal operating current, 6.90.6 Input fans power, W x 6 Heater capacity, kw.0. Unit size (height x width x depth), mm uctwork connection, mm filter for supply/exhaust air, mm Unit weight, kg Unit color 0 x 60 x 0 x 00, x 78 x 8 x 6-f7 6 RL 900 * for more detailed information look at the hot water duct air heater H specification. RGO 00P performances Temperature efficiency ir volume flowrate (m /s) Static pressure (Pa) 0 0,0 0,0 0,06 0,08 0, 0, 0, 00 0 SFP, 00 SFP 0 SFP 0,7 00 SFP 0, 0 Temperature efficiency η t (%) 90 88 86 8 8 80 78 76 7 % kw 7 0 00 00 00 00 00 600 pplication: RH 8% outdoor RH % indoor 9 8 7 6 ir volume flowrate (m /h) nergy recovery (kw) 0 0 00 00 00 00 00 600 P[kW]= SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter F7. note: characteristics explanation is available on the page 7. ir volume flowrate (m /h) RGO 00P acoustic data -weighted sound power levels L w, d(). Operation point: 80 m /h (78 l/s), 00 Pa. Octave band mid-frequency, Hz dditional inlet asing 6 0 00 000 000 000 8000 Total 7 8 60 9 7 6,9 6 66 67 6 8 0 7,8 7 8 60 9 7 6,9 6 66 67 6 9 7,0 7 6 7 60 6 9 7 66, 6 6 9 0 6,8 The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings 0 6 8 0,9

Horizontal units OMKT RGO 600H xtremely compact design with high efficiency up to 89%. Unit RGO 600H is applicable for the ventilation of premise up to 0 m and is intended for ventilation of big apartments, medium houses, conference rooms, etc. High efficiency unit with compact design can be easily installed in new premise as well as in renovated ones. The width of RGO 600H without side panels is only 70 mm. It is easy to carry such a unit into the attic through the narrow stairwell or other hard approachable places. The unit has an additional connection for air extraction from kitchen hood or other extraction device (to extract air from bathroom, laundry, etc.). Integrated automatic control with the wall mounted touch sensitive panel which is handy and simple in operation ensures the most economic unit functioning and necessary control. RGO 600H Shown as right 8 6 97 68 600 97 70 0 0 8 70 0 8 00 (x) 67 7 70 Shown as left xplication Rotary heat exchanger lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 Power supply cable dditional extraction connection (by pass extraction without heat recovery) 6

Technical information RGO 600H RGO 600HW* Supply voltage, V/Hz ~0 / 0 / phase Maximal operating current, 6.90.6 Input fans power, W x 6 Heater capacity, kw.0.0 Unit size (height x width x depth), mm uctwork connection, mm filter for supply/exhaust air, mm Unit weight, kg Unit color 600 x 0 x 70 x 00, x 7 x x 6-f7 90 RL 900 * for more detailed information look at the hot water duct air heater H specification. Static pressure (Pa) RGO 600H performances ir volume flowrate (m /s) 0 0,0 0,08 0, 0,6 00 SFP, 0 00 SFP 0 SFP 0,7 00 SFP 0, 0 Temperature efficiency η t (%) 90 88 86 8 8 80 78 Temperature efficiency % kw 76 00 00 00 00 00 600 700 pplication: RH 8% outdoor RH % indoor 9 8 7 6 ir volume flowrate (m /h) nergy recovery (kw) 0 0 00 00 00 00 00 600 700 ir volume flowrate (m /h) P[kW]= SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter F7. note: characteristics explanation is available on the page 7. RGO 600H acoustic data -weighted sound power levels L w, d(). Operation point: 0 m /h (7 l/s), 00 Pa. Octave band mid-frequency, Hz dditional inlet asing 6 0 00 000 000 000 8000 Total 6 0 8 6 8 9 6,8 7 60 6 6 60 6 9 68,8 6 0 8 6 8 0 6,0 7 60 6 6 60 6 9 68,8 6 8 9 6, 7 7 7 7, The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings 9 8 8 7,9 7

Vertical units OMKT RU 00V ouble plate heat exchanger with crosswise air flows ensures the heat recovery up to 86%. Unit RU 00V is developed and designed to create mechanical ventilation and heat recovery in flats, apartments or other residential premises up to 0 m. The supply and exhaust air flows are separated in the unit with plate heat exchanger, that is why heat from the foul air can be recovered as well. We can also recover the heat from the premise with a strong smell, e.g. from kitchen, bathroom, etc. The unit has an additional extraction connection for kitchen hood. Integrated automatic control with the wall mounted touch sensitive panel which is handy and simple in operation ensures the most economic unit functioning and necessary control. RU 00V Shown as right Special design of RU 00V allows the user to choose the needed inspection side (it is both left and right hand). The side panel of the units can be easily removed. fter the needed inspection side is chosen, the unit is turned around and the ducts are connected. Shown as left 6 77 700 xplication ouble plate heat exchanger lectric air heater 8 70 7 9 Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 utomation control system 8 y-pass damper 9 rainage 0 8 80 8 0 dditional extraction connection (by pass extraction without heat recovery) 8

Technical information RU 00V RU 00VW* Supply voltage, V/Hz ~0 / 0 / phase Maximal operating current,.0 0.76 Input fans power, W Heater capacity, kw Unit size (height x width x depth), mm uctwork connection, mm filter for supply/exhaust air, mm Unit weight, kg Unit color x 70.0 700 x 70 x 0 x 00 x 00 x 6-f7 RL 900 * for more detailed information look at the hot water duct air heater H specification. Static pressure (Pa) RU 00V performances ir volume flowrate (m /s) 0 0,0 0,0 0,06 0,08 00 SFP, 00 SFP 00 SFP 0,7 SFP 0, 00 Temperature efficiency η t (%) 90 86 8 78 7 Temperature efficiency % 70 0 0 00 0 00 0 00 0 pplication: RH 8% outdoor RH % indoor kw ir volume flowrate (m /h) nergy recovery (kw) 0 0 0 00 0 00 0 00 0 ir volume flowrate (m /h) P[kW]= SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter F7. note: characteristics explanation is available on the page 7. RU 00V acoustic data -weighted sound power levels L w, d(). Operation point: 0 m /h (8 l/s), 00 Pa. Octave band mid-frequency, Hz dditional inlet asing 6 0 00 000 000 000 8000 Total 7 9 0 9 6, 6 9 8 8 7 6, 7 9 0 9 7 6, 6 9 8 8 7 6, 0 9 8, 7 6 6,9 The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings 6,0 9

Vertical units OMKT RU 00V F nergy efficiency 8%. Unit is developed and designed to create mechanical ventilation and heat recovery in flats, apartments or other residential premise up to 0 m. High efficient plate heat exchangers and fans guarantee the most effective and economical unit operation: up to 8% of energy required for supplied air heating is recovered and used from the exhausted air. Integrated automatic control with the wall mounted touch sensitive panel which is handy and simple in operation ensures the most economic unit functioning and necessary control. RU 00V F Shown as right 0 Shown as left 6 7 8 670 60 9 0 600 xplication ounterflow plate heat exchanger (aluminium) 90 6 60 (x) lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 utomation control system 8 y-pass damper 9 rainage 66. 6 98 0

Technical information Supply voltage, V/Hz Maximal operating current, Input fans power, W Heater capacity, kw Unit size (height x width x depth), mm uctwork connection, mm filter for supply/exhaust air, mm Unit weight, kg Unit color RU 00VF RU 00VWF* ~0 / 0 / phase.8. x 0.0. 60 x 98 x 600 Ø 60 x 0 x 6-f7 RL 900 * for more detailed information look at the hot water duct air heater H specification. RU 00V F performances Temperature efficiency ir volume flowrate (m /s) Static pressure (Pa) 0 0,0 0,06 0,09 0, 00 SFP, 00 00 SFP Temperature efficiency η t (%) 90 88 86 8 % 7 6 8 kw 80 78 76 00 0 0 00 0 00 0 00 nergy recovery (kw) SFP 0,7 ir volume flowrate (m /h) 00 SFP 0, pplication: RH 8% outdoor RH % indoor 0 0 00 00 00 00 00 ir volume flowrate (m /h) P[kW]= SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter F7. note: characteristics explanation is available on the page 7. RU 00V F acoustic data -weighted sound power levels L w, d(). Operation point: 80 m /h (78 l/s), 00 Pa. Octave band mid-frequency, Hz asing 6 0 00 000 000 000 8000 Total 6 6 0 7 7, 9 9 9 0 6,9 6 6 0 7 8, 9 9 9 0 6,9 9 9 7 8 0,8 The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings 0 8 9,6

Vertical units OMKT RU 0V ouble plate heat exchanger with crosswise air flows ensures the heat recovery up to 8%. Unit RU 0V is developed and designed to create mechanical ventilation and heat recovery in flats, apartments or other residential premises up to 80 m. The supply and exhaust air flows are separated in the unit with plate heat exchanger, that is why heat from the foul air can be recovered as well. We can also recover the heat from the premise with a strong smell, e.g. from kitchen, bathroom, etc. The unit has an additional extraction connection for kitchen hood. Integrated automatic control with the wall mounted touch sensitive panel which is handy and simple in operation ensures the most economic unit functioning and necessary control. RU 0V Shown as right Special design of RU 0V allows the user to choose the needed inspection side (it is both left and right hand). The side panel of the units can be easily removed. fter the needed inspection side is chosen, the unit is turned around and the ducts are connected. Shown as left 6 77 700 xplication ouble plate heat exchanger 8 70 7 9 lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 utomation control system 0 8 y-pass damper 9 rainage 8 80 8 0 dditional extraction connection (by pass extraction without heat recovery)

Technical information RU 0V RU 0VW* Supply voltage, V/Hz ~0 / 0 / phase Maximal operating current, 6.00.6 Input fans power, W x 7 Heater capacity, kw.0. Unit size (height x width x depth), mm uctwork connection, mm filter for supply/exhaust air, mm Unit weight, kg Unit color 700 x 70 x 0 x 00 x 00 x 6-f7 RL 900 * for more detailed information look at the hot water duct air heater H specification. RU 0V performances Temperature efficiency Static pressure (Pa) ir volume flowrate (m /s) 0 0,0 0,08 0, 00 SFP, 0 SFP 00 SFP 0,7 0 SFP 0, 00 0 Temperature efficiency η t (%) 90 86 8 78 7 % kw 70 0 0 00 0 00 0 00 0 00 0 00 pplication: RH 8% outdoor RH % indoor ir volume flowrate (m /h) nergy recovery (kw) 0 0 00 00 00 00 00 ir volume flowrate (m /h) P[kW]= SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter F7. note: characteristics explanation is available on the page 7. RU 0V acoustic data -weighted sound power levels L w, d(). Operation point: m /h (88 l/s), 00 Pa. Octave band mid-frequency, Hz dditional inlet asing 6 0 00 000 000 000 8000 Total 6 6 8 6 6, 6 68 6 67 66 6 7, 6 6 8 7 6, 6 68 6 67 66 6 7, 9 8 6 9 6 6 6 67, 0 0 6 9 8 9, The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings 0 7 8,0

False-ceiling units OMKT RU 00P F nergy efficiency 9%. Unit is developed and designed to create mechanical ventilation and heat recovery in flats, apartments or other residential premise up to 00 m. High efficient plate heat exchangers and fans guarantee the most effective and economical unit operation: up to 9% of energy required for supplied air heating is recovered and used from the exhausted air. Integrated automatic control with the wall mounted touch sensitive panel which is handy and simple in operation ensures the most economic unit functioning and necessary control. RU 00P F Shown as left 7 9 0 87. 6 0 0 00 8 0 00 (x) 90 80 0 0 Shown as right 6 xplication ounterflow plate heat exchanger (polystyrene) lectric air heater Supply air filter xhaust air filter Supply fan 6 xhaust fan 7 utomation control system 8 y-pass damper 9 rainage dditional extraction connection (by pass extraction without heat recovery)

Technical information RU 00PF RU 00PWF* Supply voltage, V/Hz ~0 / 0 / phase Maximal operating current, 6.9.6 Input fans power, W x 6 Heater capacity, kw.0. Unit size (height x width x depth), mm uctwork connection, mm filter for supply/exhaust air, mm Unit weight, kg Unit color 90 x 00 x 80 Ø 00 0 x 00 x 6-f7 70 RL 900 * for more detailed information look at the hot water duct air heater H specification. Static pressure (Pa) RU 00P F performances ir volume flowrate (m /s) 0 0,0 0,08 0, 0,6 0, 00 0 SFP, 00 0 SFP 00 SFP 0,7 0 00 SFP 0, 0 Temperature efficiency η t (%) 9 9 89 87 8 8 Temperature efficiency % 8 00 00 00 00 00 600 700 pplication: RH 8% outdoor RH % indoor kw ir volume flowrate (m /h) 8 7 6 nergy recovery (kw) 0 0 00 00 00 00 00 600 700 800 P[kW]= SFP[kW (m s)] V[m s]. SFP is shown for one fan. Performance data: filter F7. note: characteristics explanation is available on the page 7. ir volume flowrate (m /h) RU 00P F acoustic data -weighted sound power levels L w, d(). Operation point: 0 m /h (97 l/s), 00 Pa. Octave band mid-frequency, Hz dditional inlet asing 6 0 00 000 000 000 8000 Total 0 6 7 0, 7 6 60 60 6 6,8 0 6 7 0, 7 6 60 60 6 6,8 8 9 7 9, 8 0 6 8 7,9 The sound data table indicates the sound power level L w which should not be confused with the sound pressure level L p. -weighted sound pressure levels L p, d(), 0 m normally isolated room, distance from casing m. Surroundings 0 7 9 6 8 6,

utomatic control KOMFOVNT OMKT control main functions: Measurements of the control panel 6 x 79 x 6 mm ontrol panel connecting cable (0 m) x 0, mm Unit operation mode selection: On/Off/uto; Setting of ventilation intensity level: 0...00%; Weekly schedule programming; Setting temperature in the control panel:...0 ; Setpoint sliding for the set period of time: +/ 9 ; Season setting: Summer/Winter; OVR function activation via external device; OVR activation by the control panel for set time period:...90 min.; Setting fans intensity level for OVR function: 0...00%; Language selection; Failures indication history: log with 0 events with time and date; Panel locking with PIN. ontrol OMKT units from any place in the world! Smart control using Komfovent Home mobile application Simple and easy control Indication of unit parameters Ventilation intensity control Supply air temperature adjustment not: air handling unit must be connected to wireless computer network or internet via PInG network module. onvenient management and control using web browser Remote control via a local computer network or the internet is realized by network module Ping. This module is provided with an integrated web server that allows you to control and monitor the HU s operation without any special software. Remote unit intensity control (OVR) OVR (eng. override ignore) function is intended for the remote unit s control with an external accessory device. fter this function is activated the current unit s mode becomes omissible and the unit starts working according to the newly set parameters. pplications of the OVR functions: Maintenance of O quantity in a room by adding a O sensor (with relay), at higher levels of O the main user-set ventilation rate will be switched to the maximum intensity until the room is ventilated, and then again will return to the user-defined intensity. Maintaining relative humidity in the room after contacting the external relative humidity sensor (with relay), automa tically switching to maximum or different set ventilation intensity the humidity level desired by the user will be maintained. Ventilation on demand when the motion sensor is connected to the control contacts, ventilation will be adjusted according to the demand, i.e. if people are indoors, ventilation will be carried out according to the set OVR intensity and if there s nobody in the room the unit will operate according to the main user intensity, for example, the minimum. Ventilation with additional air extraction connection of an additional extracting device, for example, a kitchen hood or other extraction device without a separate fan, is intended, thus the air extraction is carried out by the unit itself. fter the activation of the function the supply and exhaust air fans start operating at the maximum intensity. Negative pressure compensation intended for the systems where air extraction can be carried out in a separate air extraction fan. Thus, for the compensation of negative pressure in a room, the OVR function can be activated by the separate control contacts. fter the activation of the function the supply air fans start operating at the maximum intensity and the exhaust air fan goes off. 6

Installation of Komfovent omekt Vertical units False-ceiling units With directly integrated kitchen hood Komfovent (only for RGO 00V) With kitchen hood KOMFOVNT connected via duct With separately connected kitchen hood Komfovent With additionally connected extraction diffusers With separately connected additional extract air diffusers If a kitchen hood is not used, an extraction diffuser from the bathroom, laundry, or other premise can be connected to the unit as well. alanced ventilation system in the premise When the kitchen hood is switched on, the supply air flow in the unit increases and the exhaust one decreases automatically. This way we can feel the supply/exhaust air flows balance in the premise. note: Special units design with extremely low heights allows us to mount them horizontally, hiding by the false-ceiling or vertically on the wall. alanced ventilation system in the premise When the kitchen hood is switched on, the supply air flow in the unit increases and the exhaust one decreases automatically. This way we can feel the supply/exhaust air flows balance in the premise. important: OMKT equipment must be installed in heated premises. dditional extraction connection (by-pass extraction without heat recovery) 7

ccessories Unit in the ventilation system KOMfOVnT kitchen hoods Painted or stainless steel versions Hot water duct heaters H ir dampers with actuators 8 7 9 0 9 6 Outdoor grill for air supply/ extraction 6 Panel filters f Hot water heater regulation box vailable for all omekt units where hot water duct heater is used ir distribution box OS Only for unit RGO 00V for horizontal connection of ducts Remote unit intensity control (OVR) Ventilation system s elements Unit OMKT RGO 00V Painted front panel, stainless steel panel is optional Kitchen hood (can be enclosed according to a customer s request, possible connection of other extraction devices) Remote touch sensitive control panel Grille 6 iffuser 7 Return valve 8 Outdoor grill (for air supply/extraction) 9 amper with actuator 0 Insulated duct Regulating damper Silencer dditional extraction connection (by pass extraction without heat recovery) f Kitchen hood connection (by pass extraction without heat recovery) ifferential pressure switch TV00 Motion detector PIR80 Wall mounted temperature sensor RTT Wall mounted humidity sensor RTH uct mounted humidity sensor TH Wall mounted O sensor RT uct mounted O sensor T Wall mounted air quality sensor RTQ Ordering key xample: HU type RGO, RU Unit size Version: H horizontal, V vertical, P false-ceiling ir heater: W water, electric F counter cross flow plate y-pass damper Inspection side: R right, L left ontroller type RU 00 P F - - R - xxxx xxx x x x - x - x - x uct mounted air quality sensor TQ 8

PLUS

Komfovent producer: U malva Ozo str. 0 LT-0800 Vilnius Lithuania info@komfovent.com www.komfovent.com 0