Suction Controller SDR

Similar documents
Priming Aids ASH and AHP

Gentle Delivering and Metering Hose Pumps DULCO flex for Applications in Laboratories and Industry

~256. Ventilator. Float valve. Plugged end (INLET) Straight connection DN kpa: 1.20 l/s (instantaneous value)

Oxiperm C 164 Fully automatic chlorine dioxide processing plant C, -6000C, -7500C, C. Service manual. Oxiperm 164C 4-10 kg Service en

Safe, precise and cost-effective dosing with ProMinent Low-pressure dosing pumps up to 1,000 l/h

Here is your conveying solution: Product group D.

ProMinent ProMus Hydraulic Diaphragm Metering Pumps

NON-SLAM DYNAMIC ARV FAF 7330

Chemical Motor Pump Unit BN

Oil burners fuel unit with solenoid valve

1 L Rotary Vacuum Evaporator Instruction Manual

The Safest Connections...

9.0 Systems For Domestic Water Installations

Oil burners fuel unit with solenoid valve

System Components and Accessories for Sample Gas Conditioning. Data Sheet 10/ EN June 2004

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

TH450A-CRB TH550A-CRB THP550-CRB/TS3000

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

NOVADOS. Metering Pumps

ETP Series - Self Priming Pumps

Technical News Bulletin

Industrial peristaltic pumps

ABEL CM. Compact Diaphragm Pumps Piston Diaphragm pumps for difficult media. From the reciprocating positive displacement pump specialist

Operating instructions DULCO flex DFDa Peristaltic Pump

Safety vacuum drying oven for flammable solvents

INSTRUCTION MANUAL CLEAN BELLOWS TYPE INDUSTRIAL ROBOT SPECIFICATIONS. Notice

Pumps SELECTION OF A PUMP

Models Series Series

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

Product waste disposal - Protection of the environment:

Industrial peristaltic pumps

Automatic Moisture Control System. MYFE / MOZH. Innovations for a better world.

The sealless FLUX F 424

Solenoid diaphragm pump Series R/RS 204.1

Proportional Injector

Operating instructions DULCO flex DFDa Peristaltic Pump

Condensate Monitor CGKW. Operator s Manual 42/23-36 EN Rev. 2

SUPER METERING PUMP HY SERIES. Pulse-Free High Accuracy & High Stability ( 0.1%) Triplex Plunger Type Special Cam Drive Maintenance-Free

Supplementary Operating Manual for Cutting mill combination

System Design & Diagnostic Analysis of Group 2 Systems

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

The pump. A pump is a device that moves fluids (liquids or gases), or sometimes slurries, by mechanical action.

GRUNDFOS ALLDOS DISINFECTION. ALLDOS DISINFECTION SYSTEMS with Chlorine Gas 1 GRUNDFOS ALLDOS DISINFECTION

NOTE: Parts are no longer available for this tool. The manual will continue on the next page.

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

Model Series ELECTRIC WATER SYSTEM PUMP. PumpAgents.com - buy pumps and parts online. Model Series. Automatic Multi-Outlet FEATURES

Pump assembly Instruction manual

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Models Series Series

Oil & Gas Processing. Seal-less Pumps. Reliable Pumps for Oil and Gas Processing with No Seals or Packing to Leak or Replace

SOLUS-500 EXTRACTOR 120V

CHECK VALVES INSTALLATION

PDF-W Pneumatic drive bellows pumps F series

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, SQUATTING TOILET. To main vacuum line, connection Ø50.

Environmental protection with Swirl droplet separator (DTA)

ph Measuring System Start-up and maintenance manual e Contents

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

INSTRUCTION MANUAL FOR OIL BURNER MODELS

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

MACHINE SHOP ACCESSORIES CLEVER, TIME-SAVING PRODUCTS TO MAKE YOUR LIFE EASIER

6-2.1 ANKERSMID Diaphragm pump Application No contamination of the media AMP 510/518/530 due to oil-free operation Low maintenance

Operation Manual R205BV, R209BV

TK-1001, 1101, 1201, 1301, 1601

Why does gas build up in the oil line?

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Accu-Mix 500. Proportional Injector USER MANUAL

Rinse connection adapter CPR 40

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

Models: GW/R-T GW/R-2-T GW/R-3-T

Vacuum drying oven for non-flammable solvents

The DAUREX Quick Clean Pumps

LSM PUMPER Sigenvej 7 DK 9760 Vrå Tlf.: Fax USERS GUIDE FOR LSM PUMPS TYPE

SOLUS-310 EXTRACTOR 120V

ADVANTAGE-400H EXTRACTOR

Model: 1100 Float-Controlled Condensate Trap, PN 25

VD 53 - Vacuum drying oven for non-flammable solvents

Hand pump JP-02. Hand pump JP-02 for acids, alkalies and water-based chemicals. depending on lever position. The telescopic suction tube is adjustable

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Vacuum Pump V-100 Technical data sheet

Chapter B-2. Chapter 2. Air generation and distribution. Festo Didactic TP101

ADVANTAGE-100H-SC EXTRACTOR

Page 1 of 18. Part# /5/2013

Minor Home Repairs. November 4, County of Henrico Department of Community Revitalization

SLTC919 UNDERMOUNT RANGEHOOD INSTALLATION INSTRUCTIONS

HP310-C EXTRACTOR 120V

SOLUS-310R EXTRACTOR

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

INSTRUCTION MANUAL FOR OIL BURNER MODELS

ARBO Chemical pumps SealPro with mechanical seal. Product group 1.1

Separator Classifier. MTRB

HKF 8180 Operating instructions

TUBULAR LLdia-PUMPyy INSTRUCTIONS

The best solution for the control and the transfer of liquids and fluids Larius Industrial Technology Solutions

SOLUS-310 EXTRACTOR 120V

Leica EM CPD030 Order List Version 10/2008

Transcription:

MB 00 / Constant suction pressure and leakage stop The suction controllers SDR 0 and SDR 00 have been developed because the flow rate of diaphragm metering pumps can be affected - among other factors - by a varying suction pressure or positive suction head. Metering pumps which are mounted above the tank (e.g. underground tanks) or also below the tank deliver less the more the tank gets empty, because either the suction lift increases or the positive suction head decreases. Metering pumps with large diaphragms can develop a remarkable force on the stroke adjusting mechanism, if tank and density (e.g. sulphuric acid) are particularly high. As a result of the mass moment of inertia in long suction lines overfeeding can occur when the diaphragm or the piston suddenly stops at the stroke limiting stop. Even if backpressure valves avoid overfeeding on the discharge side, a force is created at the stroke adjusting mechanism and on the suction side which increases wear. In installations with a positive suction head towards the pump, the danger of leakage from the tank is given in the case of a diaphragm or line rupture. Under normal conditions metering pumps must not be fed directly from pressure lines, because a pressure of e.g. bar multiplied by the effective diaphragm area might exert destructive forces on the pump gear. On the other hand overfeeding would take place if a backpressure valve was not installed or wrongly adjusted on the discharge side. In the case of long suction lines cavitation can result in reduced flow rates or the destrcution of fittings due to the oscillating operation of metering pumps. The aforementioned problems can be solved by one single fitting: 0 and SDR 00 The suction controller SDR is a spring-loaded diaphragm valve which is opened by the suction pressure of the metering pump. Thus it is ensured that no medium can flow if the pump is not working or cannot create a vacuum as a result of a line rupture. Undesired suction at the pump outlet (e.g. siphoning effect) must be avoided by means of a backpressure valve. Depending on the individual operating conditions, the required maximum vacuum can be set using an adjustable spring. For pumps with a positive suction head, the vacuum to be set can be very low (approx. 0 mbar). This vacuum must be created by the pump in any case, even with a pressureless suction head. If the pump is installed below the tank only a fraction of the existing feed pressure must be produced as vacuum due to the different effective diameters of valve seat and diaphragm. For emptying underground tanks or in the case of installations where the pump is located above the tank, the vacuum required for metering is set to the maximum vacuum occuring by means of the adjusting spring. The value corresponds to an almost empty tank. Thus the pump has to prime all the time as if the tank was empty and is hardly affected by the actual filling level or suction lift. The flow in the suction line due to the mass moment of inertia will be stopped in the suction controller if the pump does not prime. In this case the suction controller must be installed close to the pump inlet in order to avoid shocks.

MB 00 / If the suction controller is also to be used as a leakage stop for the tank, it must be installed as close as possible to the tank in a mechanically protected position. In the case of line rupture, the suction controller closes immediately because of the spring force and the positive suction head effecting the locking element, since the pump cannot open the suction controller anymore due to the broken line. If the suction controller is installed close to the pump, priming of the pump becomes easier because the volume below the controller diaphragm is immediately available at the pump when priming is started. Caution! If the metering line between the pump and the process is under vacuum or tends to siphon because of the geodetic conditions, a backpressure valve must be installed at the end of the line. Functional diagram SDR 0 Functional diagram SDR 00 The liquid coming from right first faces a shut valve (valve head/valve seat +) which is closed by the spring () and sealed additionally by the liquid pressure. Thus liquid can only flow if the valve head () is pushed down by the valve pin (). This happens only after a vacuum has been produced at the left connection due to the suction stroke of the pump, causing the diaphragm () to move downwards and thus lift the valve head () off the valve seat (). The liquid coming from left first faces a shut valve (ball/seat +) which is closed by the spring () and sealed additionally by the liquid pressure. Thus liquid can only flow if the ball () is pushed down by the plunger (). This happens only after a vacuum has been produced at the right connection due to the suction stroke of the pump, causing the diaphrgam () to move downwards and press with the plunger () onto the ball (). Positive suction head If the level of the supply tank is always higher than the pump, the spring force can be set to a low value which allows the ball to just touch the seat. The positive suction head seals additionally via the ball. Therefore atmospheric pressure can practically be found on the outlet side. Consequently, the pump must only create a vacuum which is strong enough to lift the ball from the seat. Due to the large diaphragm diameter compared to the seat diameter, a very low vacuum is required. The static pressure of the tank does thus not become effective in the pump head. Negative suction head If the level of the supply tank is always below the pump, the suction controller would continuously be open in the case of a pressureless spring because the atmospheric pressure would keep the ball open via the effective diaphragm area. To ensure a constant suction lift for the pump also in this case, the spring can be pressurized so that it always simulates the

MB 00 / maximum suction lift. The pump must then prime the maximum vacuum all the time no matter if the tank is almost full or empty. (Of, course, the pump must be able to overcome the highest suction lift at all; see technical data of the pump). To set the suction pressure precisely we recommend to install a pressure gauge between suction controller and pump (see MB 00 / ). Note: For easier dry priming set the suction pressure to minimum (spring released). Only after filling the suction line and the metering head should the maximum suction pressure be adjusted. Examples of applications Installation diagram for cases a to d Legend Tank or discharge line for medium to be metered Shutoff valve Suction controller SDR Pressure gauge (optional) Pulsation dampener (is recommended for SDR 00) Metering pump Backpressure valve, if there is the danger of siphoning Installation The installation location of the suction controllers depends on its task. Due to its low weight the SDR 0 can be mounted freely in the case of rigid lines or fixed to the wall using pipe clamps.the SDR 00 should be mounted by means of the supplied pipe clamp. The preferable installation position is horizontal, the diaphragm being located at the top (SDR 0 adjusting screw downwards, SDR 00 adjusting knob upwards). Thus it is ensured that the diaphragm is not damaged at an early stage due to deposits (especially in the case of suspensions). Note: In the case of suspensions, not only the head of the metering pump should be rinsed but also the suction controller, in order to prevent failures. Frequency and duration depend on grain size and concentration of the suspension. If a pressure gauge is required the version with diaphragm pressure transmitter should be used by all means (see MB 00 / ), because thus clogging of the pressure gauge pipe spring is impossible. Note: In these examples of installation, except for the suction controller, no other fittings required or recommended are shown. a) Protection of the metering pump against excessive feed pressure due to high tanks or supply from discharge lines.

MB 00 / b) Use as tank drain protection in the case of a diaphragm failure or line rupture and avoidance of siphoning c) Avoiding changing positive and negative suction heads which affect the metering accuracy. d) Protection of the metering pump against pressure peaks due to acceleration in the case of long suction lines.

MB 00 / Dimensions SDR 0 Connections DN Fig. di da L PVC A 09 A 8 0 A 9 9 A 980 B 0 09 C 0 08 8 C 089 D G / 0 088 A B C/D Technical data of suction controller SDR Technical data 0 Max. throughput 0 l/h Max. suction head bar Max. suction pressure 00 mbar Max. temperature 0 C Weight 0. kg Connection G /8 a Material Casing PVC Diaphragm Viton EPDM Seat Viton EPDM Ball Glass Spring Hastelloy C Adjusting screw PVDF

MB 00 / Dimensions SDR 00 G / Connections 00 Fig. d L C 9 0 9 D G /8 8 90 G / 9 F - 9 G / 0 9 Ø8, Ø8, Ø8, da da L L G / G / C D Technical data of suction controller SDR 00 L Technical data 09 Max. throughout 00 l/h Max. suction head bar Max. suction pressure 00 mbar Max. temperature 0 C Weight kg Connection G / a. Material Casing PVC Diaphragm Viton Hypalon Sealing system PVDF G / F

G/ 0 MB 00 / Accessories to be mounted onto SDR 00 (optional) Description Pressure gauge NG0, stainless steel, with glycerine dampening, assembly 8 with PVC/Viton connecting parts Pressure gauge NG0, stainless steel, with glycerine dampening, assembly 8 with PVC/EPDM connecting parts for SDR 0: Description Pressure gauge assembly for SDR 0 with PVC pressure transmitter, diaphragm PTFE-coated, O-ring Viton Pressure gauge assembly for SDR 0 PVC pressure transmitter, diaphragm PTFE-loaded, O-ring EPDM 8 8 9 for SDR 00: Description Pressure gauge assembly for SDR 00 with PVC pressure transmitter, diaphragm PTFE-coated, O-ring Viton Pressure gauge assembly for SDR 00 PVC pressure transmitter, diaphragm PTFE-loaded, O-ring EPDM 8 8