SOLAR TUBE COLLECTORS

Similar documents
Solar technology VITOSOL 100-F VITOSOL 200-F VITOSOL 200-T

OVSOL Solar System Manual. Solar hot water system installation guide for evacuated tube systems.

For our present, For their future. Version 11.04

EVACUATED TUBE SOLAR HOT WATER SYSTEMS OWNERS MANUAL JULY 2013 BROCMISC100.1

The new standard. The advanced solar absorber tube. The collector for every budget. Efficient modular installation system

SELF-PRIMING JET PUMPS

Installation Instructions and Operation & Maintenance Guide

Instructions for the Use and Care and Installation of ORW6XA ORW9XA. Wall Canopy Rangehoods

Heated tools. Semiconductor equipment

Kinetico 2060f OD Sulfur Guard Installation Instructions

Solatube Daylight Dimmer Installation Instructions

Installation Manual. Read the user manual carefully before using this product

Installation Instructions

SOLAR WATER HEATING SYSTEM VERSOSUN THERMAL SOLUTIONS

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

SOLAR TECHNIQUE ATTACK SOLARTHERM, VAKUUMTHERM

Frequently Asked Questions Solar Collector G24

SOLAR WATER HEATING DIRECT SYSTEM FOR FROST-FREE LOCATIONS DOMESTIC SOLAR WATER HEATERS, SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Bar Fridge USER MANUAL MB46W

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

Solar collectors. Speaker

BASIN MIXERS INSTALLATION & AFTERCARE INSTRUCTIONS

Basin Mixer. Installation & Aftercare Instructions. Please retain for future reference.

FSLIMPRO

Installation Manual. Read the user manual carefully before using this product

Atmos EasySolar. Installation Instructions for. In-roof and flat roof installation with flat plate collectors

Portable Air-conditioner Use and Care Manual

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

LOW STATIC HYDRONIC DUCTED UNIT

2 Safety valve. 3 Pressure gauge. 4 Thermometer. 8 Ball valves

Instructions for the Use and Care and Installation of ORC97G ORC98G. Glass Canopy Rangehoods

PERFECT ORIENTATION ZONE 40 E 40 W GOOD GOOD ORIENTATION ZONE ORIENTATION ZONE

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

Solar water heating system

ORC93XA ORC94XBA. Wall Canopy Rangehoods

SOLAREKS. Natural Circulated Open Loop System SOLAREKS

Introduction. General requirements when using the heat pump

Assessment of Domestic Evacuated Tube. Direct Solar Water Heater

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

SOLAREKS. Natural Circulated Closed Loop System SOLAREKS

Brazed Plate Heat Exchanger Operations Manual

DA-9270 TWIN NEEDLE (THREE NEEDLE) FEED OFF THE ARM DOUBLE CHAIN STITCHER. English

Atmos EasySolar. Installation Instructions for. Sloping roof and flat roof installation with evacuated tube collector

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

Qualcast 430W Grass Trimmer (Model: GT2826)

Fig. 1 - Unit PHD4 and WPH4

SunRay 1000 Solar Water Pasteurizer Installation Instructions

Grain crusher Universal. Purpose: This machine is designed for the crushing of grain in agricultural operation.

General System Layout Sketch

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Dishwasher Installation Manual


SUNSEEKER BY INSTRUCTION MANUAL WARRANTY CERTIFICATE

F AN-ASPIRATED RADIATION SHIELD

FSW300 Series Flow Switch

Installation Instructions

OWNER S MANUAL. Solar Collector DELUXE

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

INSTRUCTION MANUAL Wall mounted Cooker hood Nebel INOX 90

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

XAGA 550/550-L. Aerial Splice Closure. 1. General Description. 2. Warnings. 3. Cautions

IR Intelligent Speed Dome Installation Manual

CEILING FAN OWNER'S MANUAL

INDIRECT SYSTEM FOR FROST LOCATIONS

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

BMI / BRI VERTICAL AGITATOR

Singulier Spout Tube Basin Mixer Installation and User Guide

Dedicate To be The Creator of High-quality Solar Energy Utility In The World PRODUCTS PROMOTION

Owner s Information Manual

Apricus Solar Hot Water Systems

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Models AP-10, AP-20 and AP-30

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

FRESH FLOW WASTEWATER SYSTEM

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

MACHINE GUARDING. Hazards of Unguarded Machines. Occupational Safety and Health Regulations (OSHA)

TECHNICAL MANUAL INSTALLATION, MAINTENANCE AND USE INSTRUCTIONS

Model: DC-159. Instruction Manual

COMMERCIAL SOLAR SOLUTIONS

CONTENT CONNECT GROUP FOR POULTRY PROJECT. I. Site photo. Product features and main uses. Structural characteristics and working principle

1 Introduction Basic Heliocol terminology Designing your system Parts and tools Hydraulics Installation...

Level 6 Using Physics: Investigate how physics knowledge is used in a technological application.

BEIER MACHINERY SRL-Z MIXING UNIT BEIER MACHINERY JIANGSU BEIER MACHINERY CO., LTD SUZHOU BESTAR BLOW MOLDING TECHNOLOGY CO.

Please read this manual before using the machine. Please keep this manual within easy reach for quick reference.

Retrofit an evacuated tube collector to an existing cylinder Updated

Bathroom Exhaust Fan

SECTION (15833) - HVAC POWER VENTILATORS

Hydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Alumline Radiant Heating and Cooling Ceiling Panels

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

NJWEA TECH TRANSFER MARCH 1, 2016

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

OWNERS INSTRUCTION MANUAL

Installation of Glass Lined Equipment

Transcription:

ALPHA-OMEGA SOLAR TUBE COLLECTORS ALPHA OMEGA ECOLOGICAL SOLUTIONS Athens Office: 8, R. Garibaldi & Sofroniskou str. Tel. +30.210.9228225 Email: info@alpha-omega.com.gr Direct Phones: +30.697.42 28 012 & +30.698.26 60 768 Page 1 of 25

THE COLLECTOR The collector is composed of vacuum tubes, manifold case, U pipes, tailstocks and frame. However, collector could not work independently, but should be operated together with other professional water heating system. Heat is transmitted to heat storage water tank from collector to produce hot water. The collector could be installed on roof with single plate or multiplate connected to form collector array. Page 2 of 25

FEATURES 1) Operation under pressure: No restriction on installation position. Hot water is supplied under pressure to ensure large flow and comfortable bathing. 2) Reliable system: No water leaking, scale formation in the vacuum tube. Tube explosion is avoided. The freeze-proof capacity is strong to ensure reliable operation. 3) Perfect combination with building: Optimized and elegant appearance design realizes integral combination with building in real meaning. WORKING PRINCIPLE Working principle: Vacuum tubes absorb and convert the sunlight into heat energy which will be transferred to U pipe by fins. Then, it heats the medium in the U pipe. By the circulation of the medium between U pipe and water tank, the cold water is heated. Page 3 of 25

TECHNICAL PARAMETER This product complies with GB/T17581-2007 standard. 1. PARAMETERS OF THE VACUUM TUBE 2. COLLECTOR PARAMETER Page 4 of 25

PRECAUTIONS All the installations should be carried out by qualified professional personnel, following requirements should be noticed: 1. Comply with laws and regulations stipulated by local government; 2. Roof structure, bearing capacity and water-proof measures of roof should be researched before installation; 3. Meet the requirements of the safety regulation of roof construction; 4. Be aware of safety operation of devices; 5. Installation manual of collector should be read carefully beforehand; 6. Vacuum tube under blazing sun without covering may get very high temperature over 200 c, so be careful of scalding; 7. During roof installation, take care to prevent stuff dropping from roof. 8. Wind load should be considered at collector installation. Architecture fixing point of wind-proof should refer to regulation of similar installation. 9. Tilt angle of collector should be larger than 50 to prevent gliding of snow at regions with heavy snowfall. 10. Transportation of collector should refer to the drawing below. Don t lift collector connector of collector or hit the thread to prevent deformation or damage by mechanical force, which will be unable to connect; don t hit U pipe and fin to avoid deformation, which will result in damage or failing to connect vacuum tube. Page 5 of 25

11. Qualified lightning proof expert should be consulted on lightning rod installation and lightning proof lead should be grounded outside house when installing the collectors. ASSEMBLY AND INSTALLATION OF THE COLLECTOR Collector assembly Step 1: Install seal ring at spout (factory assembly) Step 2: Install fin (factory assembly) Install fin: A. U pipe should be checked for deformation and before installation corrected to make sure the two sides of one U copper pipe are parallel; B. Install U pipe fin of one side first, fix the copper pipe into fin groove; then install the fin on another side according to the abovementioned method; C. Adjust to tightly buckle up two fins, ensure no deformation, and avoid U pipe protruding out of fin groove. Page 6 of 25

Step 3: Install wind ring (factory assembly) Install wind ring: Insert wind ring from the bottom of U pipe and push to the middle of buckling part of collector housing. Embed wind ring bulge into vacuum tube hole of collector, adjust the ring to tightly buckle up the manifold case. Step 4: Install vacuum tube Note: Cut the nylon strap fastening U pipe fins before installation. Installation steps: Wet the opening of vacuum tube or wind ring first. Then one person nip the fin tightly to combine them, another person insert the vacuum tube from the bottom of U pipe with fins on it, keep the concentricity of vacuum tube and U pipe. If insert with difficulty, you can nip fins more tightly and turn the vacuum tube. Or you can lubricate with graphite or other lubricant, then insert vacuum tube until uncoated part of the tube entering into wind ring completely. Page 7 of 25

Safety instruction: (1) Vacuum tube should not be exposed to blazing sun for a long time, otherwise people would get burned by the hot inner tube and the hot fin (the fin would become hot very soon once it touch the hot inner tube); (2) Avoid scuffing by wearing gloves during installation. Step 5: Install tailstock Installation steps: Insert the tailstock on the tail of vacuum tube. Lift the tube tail lightly (not more than 50mm), put the tailstock on the bracket, push down the tailstock along the arrow direction and fix it as the figure indicated. Note: If the bracket could not be aligned, turn the vacuum tube more into the manifold case. Otherwise, the deformation of hook under protection support may result in hook broken. Page 8 of 25

Step 6: Assembly finished, the integral schematic drawing is as following: Installation of the collector Installation of collector has two cases: on pitched roof and flat roof. Choose position to install before installation, then check and measure structure of roof on which collector will be installed. Make sure the installation area is enough, check the water proof structure and bearing condition of roof, and make fixture structure. Ensure the capacity to fight against wind load and snow load after installation. Besides, support should be firmly fixed to prevent movement by wind. Note: In order to get sufficient sun light, the direction of collector should be in accordance with local sun radiation. No barrier should stand in front of collector. Page 9 of 25

Size: Page 10 of 25

Page 11 of 25

Page 12 of 25

Page 13 of 25

Size of flat roof of collector Schematic drawing of flat roof of collector Page 14 of 25

Page 15 of 25

Page 16 of 25

Page 17 of 25

Page 18 of 25

COLLECTOR CONNECTION Both collector inlet and outlet is 15 copper pipe, and low temperature soldering is recommended connection. Note: 1) Copper pipe should be used to connect pipeline, and the material of the pipe can't be plastic. Because the temperature and pressure withstanding capacity of plastic piping will decline under high temperature, and it may result in damage of pipe; 2) During welding, end cover of collector should be protected against burning. Collector array arrangement is indicated as below Page 19 of 25

As showed in the above drawing, the longitudinal separation of the solar collectors is specified as following: When mounting several collectors, the maximum serial connection quantity of the collector should not exceed the limit indicated in the table below. The flow of branch modules in parallel connection should be the same. Therefore, equal distance of pipeline arrangement should be considered most in the piping connection of collector. The number of collectors that domestic water heating systems use is not more than four pieces, the pipe diameter should not be less than 13mm. If the gross aperture area is larger than 20m2 (approximately 10 piece of collectors)it is suggested that the diameter of inlet and outlet pipe should not be less than 20mm. Maximum connection pieces Sensor installation Temperature sensor is installed in the sensor tube at collector outlet as indicated below. Please open the end cover of the collector, then get temperature sensor through the middle hole of end cover and put it into sensor tube. Notice 1) The diameter (d) of the temperature sensor should be not more than 6mm, otherwise you are unable to install it. Page 20 of 25

2) Probe of senor should be placed in the sensor tube completely until it can not go in further; 3) Cables of the sensor should be fixed on piping insulation outside. Cable aging may occur if fixed sticking to pipe. Maintenance guidance Pipeline insulation The temperature that the insulation material for pipeline should withstand is not lower than 100. Otherwise, the high temperature of pipeline will result in damage or melting of insulation material, which will lose insulation effect. Thermal insulation shall be adopted for thermal circulation pipeline according to design. Tightness testing should be carried out before construction. All the types and thickness of insulation material should comply with the design Page 21 of 25

requirements and construction method should accord with material specification. 1. Rubber-plastic pipes are recommended as thermal insulation material for split system. Thermal insulation shall be adopted for thermal circulation pipeline, but maybe unnecessary for water supply pipeline if required by the customer. 2. Insulation thickness of thermal circulation pipeline should be not less than 20mm outside and 10mm inside, attic and basement should be not less than 20mm. 3. The thermal circulation pipeline should be wrapped with aluminium foil to protect against ultraviolet radiation. Parts list of U pipe collector Part list of pitched roof Part list of flat roof Page 22 of 25

Typical solar water heating system Page 23 of 25

Generally, solar water heating system includes collectors, storage tank, pipes and etc. There are both single circulation system and double circulation system. Page 24 of 25

Double Circulation System Page 25 of 25