Incident Summary (II )

Similar documents
Incident Summary #II (#8165) (FINAL)

Incident Summary (Reference # II )

Incident Summary (Reference # )

Incident Summary (Reference # ) (DRAFT)

tççç= ÜÉ~íáåÖ çéíáçåë

Corn Flame Energy Corn Stove Model 3000

INSTRUCTIONS FOR INSTALLATION, SETTING AND USE

LADERA. Traditional. Fireplace Design Collection EPA WOOD BURNING FIREPLACES

2006 Upgrade Kit FPX Wood Fireplaces

Chimney Fire Prevention

MONTECITO. Traditional. Fireplace Design Collection EPA WOOD BURNING FIREPLACES

CONTEMPORARY GAS FIREPLACES. CONTEMPORARY GAS FIREPLACES. woo

DaVinci Heat Exchanger

Direct Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard)

qüé=`üáãåéó An effective chimney is an important part of any successful wood-burning system.

Instructor Guide. Title: Tactical Approach to Chimney Fires. Time Required: 2 hours. Materials: PowerPoint presentation AV equipment

Heating with Wood. Part 2

DaVinci Heat Exchanger Touch-Screen Version

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

To dismantle and reassemble domestic Gas Geyser i.e. Gas Water Heater

EDVRSPV47 EDVRSPV58. Warning: What to do if you smell gas

L O S S C O N T R O L

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

Direct Vent Systems WHAT A FIRE IS MEANT TO BE

VASKA C11. gas -fireplace installation guide

MASTERTEMP HEATER REPLACEMENT PARTS

The Estate & The Esteem Direct Vent Fireplaces

Drying Groundnuts: Adapting the EasyDry M500 Portable Maize Dryer for Groundnuts

Gas Fired Humidifier. SKG Series Combustion Field Adjustment Instructions. SKG Combustion Field Adjustment Instructions

INSTALLATION AND OPERATING INSTRUCTIONS

VILLA VISTA. Traditional. Fireplace Design Collection EPA WOOD BURNING FIREPLACES

VASKA C11. gas-fireplace user manual. Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0) F.

FYRESTARTER IPI. Gas Inserts. Direct Vent Systems WHAT A FIRE IS MEANT TO BE

Real Fyre Direct Vent Inserts 2017 Product Brochure RH Peterson Co.

NEXT GENERATION OF ELECTRICAL LADLE HEATERS: A CASE STORY. Marcus Andersson. Sandvik Heating Technology, Hallstahammar, Sweden ABSTRACT

STATEMENT OF SOLID FUEL APPLIANCE PERFORMANCE

Specification and Installation Instructions

LDVPV58 Linear Power Vent System

HYBRID-FYRE FLUSH WOOD INSERTS

Flush Face Fireplace Planning Guide

Specification and Installation Instructions

Radiant Plus. Gas Fireplace Inserts

City Series CC40RE Gas Fireplace

Specialists in fireplace design and manufacture CUBE DOUBLE SIDED INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT:

The Sherwood Home Collection

Carbon monoxide (CO) is a colorless, odorless gas that is the product of incomplete combustion of carbon-based fuels.

argos: model specifications Technical Data 2 Installation 3 Operate the Argos 5 Safety Rules 8 Certification 9

CHAPTER 8 CHIMNEYS AND VENTS

^ STUV 21: MODEL SPECIFICATIONS

Flush Wood Hybrid-Fyre Inserts

Inspection Checklist Mechanical Rough in

the flame of the future

Whole House Action Guidelines

COMBINATION SOLUTION FOR COLLECTIVE FLUE, AIR VENTILATION AND EXHAUST

City Series CV40E Gas Fireplace

Flush Wood Hybrid-Fyre Inserts

Green Building Practice Summary 3/10/2011

studio gas fires 57 Industrial Drive, Braeside, Victoria

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

COMBUSTION AIR SYSTEM

Why our flame is so natural... Our Technology & Engineering Excellence. Efficiency. Safety & Reliability. Fully Remote Controlled

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

,4X IMPORTANT SAFETY INSTRUCTIONS

Rocket heater GAMERA

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

Natural Gas Appliance Testing Action Guidelines (Non ESA/Low Income 5 )

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

CHAPTER 8 CHIMNEYS AND VENTS

USER'S INFORMATION MANUAL

Causes and Advice on Condensation

CHIMNEYS AND VENTS CHAPTER 8

FCX FUEL OIL CONDENSING BOILER RANGE

Evolve 951 & Product specification pages

VENTING GAS APPLIANCES NFPA 54 CODE

Venting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness

VASKA B11. gas -fireplace installation guide

SAUNA HEATER INSTALLATION AND OPERATING MANUAL

Southern Series. Free-Standing Wood Burner

GB162 Concentric Horizontal Vent Kit

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations.

Aquaflam Wood boiler stoves and fireplace inserts

The Complete Guide to Gas Hearth Products. Table of Contents

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.)

Model 31 and 33 DVI Fi rest y l es for Life

Incident Summary (Reference # )

User's Information Manual Customer Property: Contains wiring and service information.

TOYOTOMI U.S.A., INC. P.O. Box 176, Brookfield, CT

SB615/310 Stainless Steel Condensing Boiler

Technical Datasheet. FHG-S Models 28, and 45. Benefits at a Glance: State Route 22 Salem, NY 12865

1. GENERAL SAFETY RULES

2012 INTERNATIONAL FUEL GAS CODE VENTS

City Series CB40E Gas Fireplace

Chapter One Commercial Kitchen Fires

A wood heater that s right for every home! THE FLAME OF THE FUTURE

Combination Cooling/Gas Heat Package Units

Main components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens

Transcription:

Incident Summary (II-636492-2018) Incident Date December 15, 2017 Location Langley SUPPORTING INFORMATION Regulated industry sector Impact Injury Damage Qty injuries 0 Injury description Injury rating Damage description Incident rating Damage rating Natural gas system None None Fire damage was contained to exterior wall behind gas fireplace termination Minor Minor Incident overview A new installation of a gas fireplace installed in a two year old home overheated the combustible wall and caused a minor fire at the side wall termination The fireplace installation was a direct vent installation, the chimney has a five inch inside pipe for exhausting the flue products and a eight inch outside pipe for combustion air that extends from the fireplace flue connection to the side wall exhaust termination allowing for sealed combustion, this fireplace is sealed from the interior of the home and uses outside air for combustion. When this type of fireplace is installed the manufactures tests and certifies the installation with required clearances to the fireplace shell and venting materials INVESTIGATION CONCLUSIONS Site, system and components To begin the operation of the fireplace unit, the user must turn on the gas supply and ignite the burners. Once this is done, the unit will operate completely autonomously until the gas supply to the burners is shut off. While in operation, convection will cause the hot air in the firebox to rise to the top of the firebox. As the amount of hot exhaust gasses increases from the combustion process, the hot gas at the top of the firebox is eventually pushed out through the inner flue. At the same time, the removal of the exhaust gasses through the inner flue allows for relatively cold air to be drawn into the firebox through the outer flue. As the firebox heats up due to the operation of the burners, it radiates heat into the room through the porous glass face that separates the firebox from the inside of the room. At the same time, it transfers heat through the surrounding metal walls into the empty space in between itself and the outer housing. This heat transfer creates a convection process inside of the empty space that is very similar to the one that takes place inside of the firebox. Built into the design of the room facing side of the unit are two vents, one at the top and one at the bottom. Once the air in the empty space begins to heat up, convection pushes this heated air further up in the chamber until it is eventually pushed out through the top vent. This phenomenon works in the same way to draw air in through the bottom vent. As the hot air is pushed out, space is emptied in the chamber behind the firebox, which then draws cold air in through the bottom vent.

Incident Summary (II-636492-2018) Both of these convection processes immediately begin to slow down, and eventually stop, as soon as the burners turn off. Failure scenario(s) Home owner was using fireplace when fire occurred caused by flue gas (heat) escaping from venting system into combustible space just behind vent termination. - Two year old installation confirmed by gas permit - Conversation with owner, he indicated that the fireplace was used 6-8 times over the last two years Facts and evidence - Photographic evidence indicates that the fires origin was directly behind the fireplace vent termination - The fire was contained to the area behind the vent termination by the building fire stopping based on the photographic evidence. Causes and contributing factors - The plausible cause of this fire was that the vent pipe and intake piping was split open inside the combustible area directly behind the vent termination allow flue gases to escape which caused the wood framing to catch on fire Photos or diagrams (if necessary)

Interior view

Location of fire origin

Damage to exterior wall

Shows heat was most intense at top edge

Top and front view of termination