Landmark Rooftop Units 50 HZ

Similar documents
T CLASS ROOFTOP UNITS 60HZ Bulletin No July 2008 Supersedes August 2007

T CLASS ROOFTOP UNIT 50HZ 24.8 to 38.8 kw (84,800 to 132,700 Btuh) Bulletin No August 2005 Supersedes December 2004

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

RGE 13 A T - 1 A

LGH. E-Series Rooftop Units 50 HZ

LGH. Energence Rooftop Units 50 HZ

E-Series Rooftop Units 60 HZ

13 GEP A L P - 1 A

L SERIES ROOFTOP UNITS 60 HZ

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

LGH. Energence Ultra-High Efficiency Rooftop Units 60 HZ

E-Series Rooftop Units 60 HZ

TGA WARNING CAUTION ROOFTOP UNITS. Service Literature. Table of Contents

E-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT. 13 to 25 Tons Net Cooling Capacity 152,000 to 270,000 Btuh Optional Electric Heat - 15 to 90 kw

L SERIES ROOFTOP UNITS 60 HZ

Energence Rooftop Units 60 HZ

Corp L2 Revised

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Energence Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT. 13 to 25 Tons Net Cooling Capacity 152,000 to 270,000 Btuh Optional Electric Heat - 15 to 90 kw

E-Series Rooftop Units 50 HZ

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

L SERIES ROOFTOP UNITS 60 HZ

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

48PGD/E/F/L/M/N PG20-28

LCA/LGA. PACKAGED L SERIES 50hz. 25 & 30 Ton (87.9 & kw) Bulletin # December 1995 ENGINEERING DATA. Table of Contents

48TF GAS HEATING/ ELECTRIC COOLING UNITS

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

LCH. Energence Rooftop Units 60 HZ

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

LGH. E-Series Rooftop Units 60 HZ

LCH. E-Series Rooftop Units 60 HZ

48TM GAS HEATING/ELECTRIC COOLING UNITS

Energence Ultra-High Efficiency Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT

L SERIES ROOFTOP UNITS 60 HZ

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

T P A 120 S 4 S N 1 Y

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCG Commercial. Submittal Data Form

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

8+* Bulletin No November 1997

TGA WARNING CAUTION ROOFTOP UNITS. Service Literature. Table of Contents

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

KGA/KGB UNITS WARNING

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

50TM COMBINATION HEATING/COOLING UNITS

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

Submittal Data Performance Data Electrical Data

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

MERIT SERIES Downflow

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

MERIT Series R-410A - Upflow / Horizontal

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

MERIT SERIES Up Flow / Horizontal

ELITE SERIES Downflow - High Efficiency Blower Motor

MERIT Series R-410A - Upflow / Horizontal

50TM TFF COMBINATION HEATING/COOLING UNITS

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

T S A 048 S 4 N 4 1 T

G34M Bulletin #69/ August 2003

Ruud Commercial Achiever Series Package Gas Electric Unit

RHEEM PACKAGE GAS/ELECTRIC

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

SKYPAK II, 3 Ton Series, gives you a

PRPDF16 PRODUCT SPECIFICATIONS PRP DF P A SINGLE STAGE GAS VALVE TWO STAGE COMPRESSOR VARIABLE SPEED BLOWER

SKYPAK II, 3 Ton Series, gives you a

Commercial High-Efficiency Condensing Units

HEAT EXCHANGER Aluminized serpentine clamshell heat exchanger provides corrosion resistance for longer life and efficient heat transfer.

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

PACKAGE AIR CONDITIONER

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

62DA,DB,DC,DD,DE,DF07-38

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

T-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS MODELS UP TO 12.0 EER

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Transcription:

E N G I N E E R I N G D ATA P A C K A G E D G A S E L E C T R I C KG Landmark Rooftop Units 50 HZ Bulletin No. 49045 November 200 Supersedes August 200 52.8 to 88 kw (5 to 25 Ton) Net Cooling Capacity - 46.6 to 70.9 kw (59 000 to 242 000 Btuh) Gas Input Heat Capacity 49.5 to 23.0 kw (69 000 to 420 000 Btuh) MODEL NUMBER IDENTIFICATION Brand/Family K = Landmark Unit Type G = Packaged Gas Heat w/ Electric Cooling Major Design Sequence A = st Generation Nominal Cooling Capacity - kw 80 = 52.8 kw 20 = 6.5 kw 240 = 70.3 kw 300 = 88 kw Cooling Efficiency S = Standard Efficiency K G A 240 S 4 B S M Heating Type S = Standard Gas Heat, 2 Stage M = Medium Gas Heat, 2 Stage H = High Gas Heat, 2 Stage Blower Type B = Belt Drive Refrigerant Type 4 = R-40A Voltage M = 380/420V-3 phase-50hz Minor Design Sequence = st Revision 2 = 2nd Revision 3 = 3rd Revision

FEATURES AND BENEFITS H D O M N L G I J C F E K B Landmark rooftop units from Lennox are the new standard for reliable, efficient rooftop units built for long-lasting performance that can significantly improve indoor and outdoor environments. Landmark rooftop units feature: Aluminized Steel Heat Exchanger With Inshot Burners - Life cycle tested. R-40A Refrigerant - Environmentally friendly Scroll Compressors - Single speed scroll compressors are furnished on all models. Crankcase Heaters - Protect compressors from refrigerant liquid migration in the off cycle improving product reliability. High Pressure Switches - Protect compressor. Isolated Compressor Compartment - Allows performance check during normal compressor operation without disrupting airflow. Independent Motor Mounts - Allows for easy and efficient service access without removing the top panel. Downflow Airflow - Horizontal airflow with optional horizontal curb. Two Fork Lift Slots on Three Sides - Easy to pick up and transport units from almost any angle. Corrosion-Resistant Removable, Drain Pan - Provides application flexibility, durability and improved serviceability. Thermostatic Expansion Valves - Provide peak cooling performance across the entire application range. MERV 8 or MERV 3 Filters - Available as field installed option, provide an enhanced level of indoor air quality, and can help the building qualify for additional Leadership in Energy and Environmental Design (LEED) credits. Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 2

FEATURES AND BENEFITS Contents Accessory Dimensions...........................25 Blower Data................................ 5 Dimensions.................................23 Electrical Data............................... 9 Features And Benefits........................... 2 High Altitude Derate............................2 Model Number Identification........................ Optional Conventional Temperature Control Systems...........2 Options / Accessories............................ 8 Outdoor Sound Data............................2 Ratings...................................3 Specifications................................ Specifications - Gas A Heat......................... 2 Unit Clearances.............................. 20 Weight Data................................ 22 PERFORMANCE/QUALITY Components bonded for grounding to meet safety standards for servicing required by Underwriters Laboratories (UL) and the International Electrotechnical Commission (IEC). Cooling performance is rated at test conditions included in Air-Conditioning, Heating and Refrigeration (AHRI) Standard 340/360-2007 while operating at rated voltage and air volumes. International Organization for Standardization (ISO) 900 Registered Manufacturing Quality System. B HEATING SYSTEM Aluminized steel inshot burners, direct spark ignition, electronic flame sensor, combustion air inducer, redundant automatic dual stage gas valve with manual shut-off. Heat Exchanger Tubular construction, aluminized steel, life cycle tested. Optional Stainless Steel Heat Exchanger is required if mixed air temperature is below 7 C. Electronic Pilot Ignition Solid-state electronic spark igniter provides positive direct ignition of burners on each operating cycle. The system permits main gas valve to stay open only when the burners are proven to be lit. Should a loss of flame occur, the gas valve closes, shutting off the gas to the burners. Ignition module has light emitting diode (LED) to indicate status and aid in troubleshooting. Ignition control is factory installed in the controls section. Limit Controls Factory installed, redundant limit controls with fixed temperature setting. Heat limit controls protect heat exchanger and other components from overheating. Safety Switches Flame roll-out switch, flame sensor and combustion air inducer proving switch protect system operation. REQUIRED SELECTIONS Gas Input Choice - Order one: Standard Gas Heat, 2 Stage (49.5/76. kw) Medium Gas Heat, 2 Stage (68.5/05.4 kw) High Gas Heat, 2 Stage (9.4/40.5 kw) OPTIONS/ACCESSORIES Factory Installed Stainless Steel Heat Exchanger Required if mixed air temperature is below 7 C. Field Installed Bottom Gas Piping Kit Allows bottom gas entry. Combustion Air Intake Extensions Recommended for use with existing flue extension kits in areas where high snow areas can block intake air. Order two kits. LPG/Propane Kits Conversion kit to field change over units from Natural Gas to LPG/ Propane. Order two kits. Vertical Vent Extension Kit Use to exhaust flue gases vertically above unit. Required when unit vent is too close to fresh air intakes per building codes. The vent kit also prevents ice formation on intake louvers. Order two kits. Kit contains vent transition, vent tee, drain cap and installation hardware. NOTE - Straight vent pipes (4 inch B-Vent) and caps are not furnished and must be field supplied. Refer to kit instructions for additional information. Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 3

C D E F FEATURES AND BENEFITS COOLING SYSTEM Designed to maximize sensible and latent cooling performance at design conditions. System can operate from C to 52 C without any additional controls R-40A Refrigerant Non-chlorine based, ozone friendly, R-40A. Scroll Compressors Scroll compressors on all models for high performance, reliability and quiet operation. Resiliently mounted on rubber grommets for quiet operation. Compressor Crankcase Heaters Protects against refrigerant migration that can occur during low ambient operation. Thermal Expansion Valves Assures optimal performance throughout the application range. Removable element head. Filter/Driers High capacity filter/drier protects the system from dirt and moisture. High Pressure Switches Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation. Freezestats Protects the evaporator coil from damaging ice build-up due to conditions such as low/no airflow, or low refrigerant charge. Coil Construction Copper tube construction, enhanced rippled-edge aluminum fins, flared shoulder tubing connections, silver soldered construction for improved heat transfer. Factory leak tested. Evaporator Coil Cross row circuiting with rifled copper tubing optimizes both sensible and latent cooling capacity. G Condenser Coil Angled, slab design helps protect coil from possible contact or hail damage. Condensate Drain Pan Plastic, sloped drain pan. Side or bottom drain connections. Outdoor Coil Fan Motors Thermal overload protected, totally enclosed, permanently lubricated ball bearings, shaft up, wire basket mount. Outdoor Coil Fans Polyvinyl chloride (PVC) coated fan guard furnished. REQUIRED SELECTIONS Cooling Capacity Specify nominal cooling capacity of the unit OPTIONS/ACCESSORIES Field Installed Condensate Drain Trap Available in copper or polyvinyl chloride (PVC). Drain Pan Overflow Switch Monitors condensate level in drain pan, shuts down unit if drain becomes clogged. Low Ambient Kit Cycles the outdoor fan while allowing compressor operation in the cooling cycle. This intermittent fan operation allows the system to operate without icing the evaporator coil and losing capacity. Designed for use in ambient temperatures no lower than 0 F. H CABINET Construction Heavy-gauge steel panels and full perimeter heavy-gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation. Base rails have rigging holes. Three sides of the base rail have forklift slots. Raised edges around duct and power entry openings in the bottom of the unit provide additional protection against water entering the building. Airflow Choice Units are available in downflow (vertical) or horizontal return air flow configuration. Horizontal air flow requires Horizontal Roof Curb. Horizontal Return Air Panel Kit is also required if converting a downflow configured unit to horizontal air flow. Power/Gas Entry Electrical and gas lines can be brought through the unit base or through horizontal access knockouts Exterior Panels Constructed of heavy-gauge, galvanized steel with a two-layer enamel paint finish. Insulation All panels adjacent to conditioned air are fully insulated with nonhygroscopic fiberglass insulation. Unit base is fully insulated. The insulation also serves as an air seal to the roof curb, eliminating the need to add a seal during installation. Access Panels Access panels are provided for the economizer/filter section, heating/blower section, and the compressor/controls section. Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 4

FEATURES AND BENEFITS OPTIONS/ACCESSORIES Factory Installed Corrosion Protection A completely flexible immersed coating with an electrodeposited dry film process. (AST ElectroFin E-Coat) Meets Mil Spec MIL-P-53084, ASTM B7 Standard Method Salt Spray Testing. Indoor Corrosion Protection: - Coated coil - Painted blower housing - Painted indoor base Outdoor Corrosion Protection: - Coated coil - Painted outdoor base Hinged Access Panels Hinged access panels for the filter section, the blower section and compressor/controls section. All hinged panels have seals and quarter-turn latching handles to provide a tight air and water seal. Field Installed Coil Guards Painted, galvanized steel wire guards to protect outdoor coil. Not used with Hail Guards. Hail Guards Constructed of heavy gauge steel, painted to match cabinet, helps protect outdoor coils from hail damage. Not used with Coil Guards. Horizontal Return Air Panel Kit Required for horizontal applications with Horizontal Roof Curb, contains panel with return air opening for field replacement of existing unit panel and panel to cover bottom return air opening in unit, see dimension drawings. I BLOWER A wide selection of supply air blower options are available to meet a variety of airflow requirements. Motor Overload protected, equipped with ball bearings. Belt drive motors are offered on all models and are available in several different sizes to maximize air performance. Supply Air Blower Forward curved blades, double inlet, blower wheel is statically and dynamically balanced. Equipped with ball bearings and adjustable pulley (allows speed change),. Blower assembly slides out of unit for servicing. REQUIRED SELECTIONS Order blower motor output and drive kit number required when base unit is ordered, see Drive Kit Specifications Table. J CONTROLS Unit Control All control voltage is provided via a 24V (secondary) transformer with built-in circuit breaker protection. Heat/Cool Staging - Capable of up to 2 heat / 2 cool staging with a third party DDC control system or thermostat. Low Voltage Terminal Block - Provides screw terminal connections for thermostat or controller wiring. Night Setback Mode - Saves energy by closing outdoor air dampers and operating supply fan on thermostat demand only. OPTIONS/ACCESSORIES Field Installed Smoke Detector Photoelectric type, installed in supply air section, return air section or both sections. Available with power board and single sensor (supply or return) or power board and two sensors (supply and return). Power board located in unit control compartment. Commercial Control Systems L Connection Network Complete building automation control system for single or multizone applications. Options include local interface, software for local or remote communication, and hardware for networking other control functions. See L Connection Network Engineering Handbook Bulletin for details. Thermostats Control system and thermostat options. Aftermarket unit controller options. See page 2. Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 5

K FEATURES AND BENEFITS ELECTRICAL REQUIRED SELECTIONS Voltage Choice Specify when ordering base unit. OPTIONS/ACCESSORIES Factory or Field Installed Disconnect Switch Accessible from outside of unit, spring loaded weatherproof cover furnished. L INDOOR AIR QUALITY Air Filters Disposable 2 inch filters furnished as standard. OPTIONS/ACCESSORIES Field Installed High Efficiency Air Filters Disposable MERV 8 or MERV 3 (Minimum Efficiency Reporting Value based on ASHRAE 52.2) efficiency 2 inch pleated filters. Healthy Climate UVC Germicidal Lamps Germicidal lamps emit ultra-violet (UV-C) energy, which has been proven to be effective in reducing microbes such as viruses, bacteria, yeasts, and molds. This process either destroys the organism or controls its ability to reproduce. UV-C energy greatly reduces the growth and proliferation of mold and other bioaerosols (bacteria and viruses) on illuminated surfaces (particularly coil and drain pan). Lamps are field installed in the blower/evaporator coil section. All necessary hardware for installation is included. Lamps operate on 220V singlephase power supply. Step-down transformer may be ordered separately for 380/420V primary to 220V secondary units. Alternately, 220V power supply may be used to directly power the UVC ballast(s). Indoor Air Quality (CO 2 ) Sensors Monitors CO 2 levels, reports to the Unit Controller which adjusts economizer dampers as needed. SERVICEABILITY Designed to streamline general maintenance and decrease troubleshooting time. Marked & Color-Coded Wiring All electrical wiring is color-coded and marked to identify which components it is connecting. Electrical Plugs Positive connection electrical plugs are used to connect common accessories or maintenance parts for easy removal or installation. Access Panels Large access panels are provided for quick and easy access to maintenance areas. Blower Access Supply air blower parts are located near the access door for easy servicing and adjustment. Thermal Expansion Valve Access Thermal expansion valves are located near the perimeter of the unit for easier access. Removable element head allows change out of element and bulb without removing the TXV. Coil Cleaning Slab condenser coils provided for easier cleaning. Standard Components A large number of common maintenance parts are standard throughout the entire range of sizes, reducing the need to carry a lot of different parts to the job or maintain in inventory. Compressor Compartment Compressors are located near the perimeter of the unit for easier access. Compressors are isolated from the condenser airflow allowing system operation checks to be done without changing the airflow across the outdoor coils. Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 6

M N FEATURES AND BENEFITS ECONOMIZER/EXHAUST OPTIONS Factory or Field Installed Economizer - Downflow or Horizontal With Outdoor Air Hood Parallel gear-driven action return air and outdoor air dampers, plug-in connections to unit, nylon bearings, neoprene seals, 24-volt, fully-modulating, spring return motor, adjustable minimum damper position. Outdoor air hood is furnished. Single sensible control is furnished with economizer. Outdoor air temperature sensor enables economizer if the outdoor temperature is less than the setpoint of the control. Outdoor Air Hood is included when economizer is factory installed and is furnished with economizer when ordered for field installation. Field Installed Single Economizer Enthalpy Control Enthalpy sensor enables the economizer when the outdoor air enthalpy is below the configured setpoint. Differential (Dual) Economizer Enthalpy Control Order two single, enthalpy control kits. One is field installed in the return air section, the other in the outdoor air section. Allows the economizer control board to select between outdoor air or return air, whichever has lower enthalpy. Downflow Barometric Relief Dampers With Exhaust Hood Allow relief of excess air. Aluminum blade dampers prevent blow back and outdoor air infiltration during off cycle. Exhaust hood with bird screen is furnished. O Horizontal Barometric Relief Dampers With Exhaust Hood For use when unit is configured for horizontal applications requiring an economizer. Allows relief of excess air Aluminum blade dampers prevent blow back and outdoor air infiltration during off cycle. Field installed in return air duct. Exhaust hood with bird screen is furnished. Power Exhaust Fan Installs internal to unit for downflow applications only with economizer option. Provides exhaust air pressure relief. Interlocked to run when supply air blower is operating, fan runs when outdoor air dampers are 50% open (adjustable), motor is overload protected. Requires Economizer with Outdoor Air Hood and Downflow Barometric Relief Dampers. Dual fans are 508 mm diameter with 5 blades with (2) 0.22 kw motors. OUTDOOR AIR OPTIONS Factory or Field Installed Outdoor Air Damper - Downflow or Horizontal With Air Hood Linked mechanical dampers, 0 to 25% (fixed) outdoor air adjustable, installs in unit. Includes outdoor air hood. Automatic model features fully modulating spring return damper motor with plug-in connection. Manual model features parallel blade, gear-driven dampers with adjustable fixed position. Outdoor Air Hood is included when damper is factory installed and is furnished with damper when ordered for field installation. ROOF CURBS Nailer strip furnished, mates to unit, US National Roofing Contractors Approved, shipped knocked down. Downflow Clip Curbs - Uses interlocking tabs to fasten corners together. No tools required. Standard Curbs - Curb corners fasten together with furnished hardware. Adjustable Pitched Curb - Curbs are regionally sourced. Dimensions will vary based upon the source. Contact your Lennox sales representative for a detailed cut sheet with applicable dimensions. Horizontal Converts unit from downflow to horizontal (side) air flow, return air is on unit, supply air is on curb, see dimension drawings. Curbs for rooftop applications meet National Roofing Code requirements. Requires Horizontal Return Air Panel Kit. Available in 660, 762, 940 and 04 mm heights. Optional Insulation Kit is available to help prevent sweating. CEILING DIFFUSERS Ceiling Diffusers (Flush or Step-Down) Aluminum grilles, large center grille, insulated diffuser box with flanges, hanging rings furnished, interior transition (even air flow), internally sealed (prevents recirculation), adapts to T-bar ceiling grids or plaster ceilings. Transitions (Supply and Return) Used with diffusers, installs in roof curb, galvanized steel construction, flanges furnished for duct connection to diffusers, fully insulated. Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 7

OPTIONS / ACCESSORIES Item Description Model Number Catalog Number Unit Model No 80 20 240 300 COOLING SYSTEM Condensate Drain Trap Polyvinyl Chloride (PVC) - CTRAP20AD2 76W26 X X X X Copper - CTRAP0AD2 76W27 X X X X Corrosion Protection Factory O O O O Drain Pan Overflow Switch KSNSR7C-- 68W89 X X X X Efficiency Standard O O O O Low Ambient Kit KSNSR33C- 55W72 X X X X Refrigerant Type R-40A O O O O HEATING SYSTEM Bottom Gas Piping Kit CGPKT0C- 85M3 X X X X Combustion Air Intake Extensions (order two) LTACAIK0/5 89L97 X X X X Gas Heat Input Standard - 76. kw Factory O O O O Medium - 05.4 kw Factory O O O O High - 40.5 kw Factory O O O O LPG/Propane Conversion Kits (Order 2 kits) Standard heat - LTALPGK-30 72M94 X X X X Medium heat - LTALPGK-80 72M95 X X X X High heat - LTALPGK-240 72M96 X X X X Stainless Steel Heat Exchanger Factory O O O O Vertical Vent Extension Kit (Order two kits) CEXTN20FF 42W6 X X X X BLOWER - SUPPLY AIR Motors Belt Drive - 2.2 kw Factory O O Belt Drive - 3.7 kw Factory O O O O Belt Drive - 5.6 kw Factory O O O O Belt Drive - 7.5 kw Factory O O Drive Kits See Blower Data Tables for usage and selection Kit # 446-604 rev/min Factory O O Kit #2 57-72 rev/min Factory O O Kit #3 57-72 rev/min Factory O O O O Kit #4 708-87 rev/min Factory O O O O Kit #5 788-988 rev/min Factory O O O O Kit #6 708-87 rev/min Factory O O O O Kit #7 788-988 rev/min Factory O O O O Kit #8 87-07 rev/min Factory O O O O Kit #0 87-07 rev/min Factory O O Kit # 945-38 rev/min Factory O O CABINET Coil Guards CGARD20C 54W79 X X CGARD20C3 54W80 X X Hail Guards CGARD0C 54W83 X X CGARD0C3 54W84 X X NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Field Installed O = Configure To Order (Factory Installed) X = Field Installed Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 8

OPTIONS / ACCESSORIES Item Description CONTROLS Model Number Catalog Number Unit Model No 80 20 240 300 Smoke Detector - Supply or Return (Power board and one sensor) CSNSR44C- 53W82 X X X X Smoke Detector - Supply and Return (Power board and two sensors) CSNSR43C- 53W83 X X X X INDOOR AIR QUALITY Air Filters Healthy Climate High Efficiency Air Filters 60 x 60 x 5 mm (Order 6 per unit) Replacement Media Filter With Metal Mesh Frame (includes non-pleated filter media) Indoor Air Quality (CO 2 ) Sensors MERV 8 - CFLTR5C-- 54W67 X X X X MERV 3 - CFLTR40C-- 52W40 X X X X CFLTR30C-- 44N6 X X X X Sensor - Wall-mount, off-white plastic cover with LCD display C0SNSR50AEL 77N39 X X X X Sensor - Wall-mount, off-white plastic cover, no display C0SNSR52AEL 87N53 X X X X Sensor - Black plastic case with LCD display, rated for plenum mounting C0SNSR5AEL 87N52 X X X X Sensor - Wall-mount, black plastic case, no display, rated for plenum mounting C0MISC9AE 87N54 X X X X CO 2 Sensor Duct Mounting Kit - for downflow applications C0MISC9AE- 85L43 X X X X Aspiration Box - for duct mounting non-plenum rated CO 2 sensors (87N53 or 77N39) UVC Germicidal Light Kit C0MISC6AE- 90N43 X X X X Healthy Climate UVC Light Kit (220V-ph) CUVCL0C- 54W65 X X X X ELECTRICAL Voltage 50 hz with neutral 380/420V - 3 phase Factory O O O O ECONOMIZER Economizer Economizer - Downflow or Horizontal (Outdoor Air Hood furnished) Economizer Controls KECON20C- 54W77 OX OX OX OX Differential Enthalpy Order 2 - CSNSR64FF 53W64 X X X X Single Enthalpy CSNSR64FF 53W64 X X X X Downflow Barometric Relief Dampers Barometric Relief Dampers with Exhaust Hood CDAMP50C 54W78 OX OX OX OX Horizontal Barometric Relief Dampers Barometric Relief Dampers with Exhaust Hood LAGEDH8/24 6K99 X X X X OUTDOOR AIR Outdoor Air Dampers Motorized Dampers with Outdoor Air Hood KDAMP20C- 58W62 OX OX OX OX Manual Dampers With Outdoor Air Hood CDAMP0C- 54W76 OX OX OX OX POWER EXHAUST Standard Static 380/420V - CPWRE0C-M 54W73 X X X X Lamps operate on 220V single-phase power supply. Step-down transformer may be ordered separately for 380/420V primary to 220V secondary units. Alternately, 220V power supply may be used to directly power the UVC ballast(s). NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Field Installed O = Configure To Order (Factory Installed) X = Field Installed Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 9

OPTIONS / ACCESSORIES Item Description ROOF CURBS - DOWNFLOW Clip Curb Model Number Catalog Number Unit Model No 80 20 240 300 203 mm height CCURB40CD 26W32 X X X X 356 mm height LARMF8/30S-4 33K44 X X X X 457 mm height LARMF8/30S-8 33K45 X X X X 60 mm height LARMF8/30S-24 33K46 X X X X Standard 203 mm height LARMF8/36-4 6K87 X X X X 60 mm height LARMF8/36-24 6K88 X X X X Adjustable Pitched Curb 203 mm height LCURB55C 43W26 X X X X ROOF CURBS - HORIZONTAL (REQUIRES HORIZONTAL RETURN AIR PANEL KIT) Standard 660 mm height - slab applications LARMFH8/24-26 97J33 X X X 940 mm height - rooftop applications LARMFH8/24-37 38K53 X X X 762 mm height - slab applications LARMFH30/36-30 33K79 X 04 mm height - rooftop applications LARMFH30/36-4 38K54 X Insulation Kit For Standard Horizontal Curbs for LARMFH8/24-26 CINSUC-- 73K32 X X X for LARMFH8/24-37 CINSU3C-- 73K34 X X X for LARMFH30/36-30 CINSU2C-- 73K33 X for LARMFH30/36-4 CINSU4C-- 73K35 X Horizontal Return Air Panel Kit Required for Horizontal Applications with Roof Curb CHRAP0C-- 87M00 X X X X CEILING DIFFUSERS Step-Down - Order one RTD-85 29G06 X RTD-275-R 29G07 X X X Flush - Order one FD-85 29G0 X FD-275-R 29G X X X Transitions (Supply and Return) - Order one LASRT8 9K0 X NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Field Installed O = Configure To Order (Factory Installed) X = Field Installed LASRT2/24 9K02 X X X Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 0

SPECIFICATIONS General Data Nominal kw (Tons) 52.8 (5) 6.5 (7.5) 70.3 (20) 88 (25) Model Number KGA80S4B KGA20S4B KGA240S4B KGA300S4B Efficiency Type Standard Standard Standard Standard Blower Type Constant Air Volume CAV Constant Air Volume CAV Constant Air Volume CAV Constant Air Volume CAV Cooling Performance Gross Cooling Capacity - kw (Btuh) 48.3 (65 000) 54.5 (86 000) 63.0 (25 000) 74.7 (255 000) Net Cooling Capacity - kw (Btuh) 46.6 (59 000) 52.7 (80 000) 60. (205 000) 70.9 (242 000) AHRI Rated Air Flow - L/s (cfm) 2830 (6000) 2890 (625) 3635 (7700) 430 (8750) Total Unit Power - kw 4.6 6.4 8.8 24.2 EER (Btuh/Watt) 0.9 0.9 0.9 0.0 2 IEER (Btuh/Watt).0.0.0 9.9 Refrigerant Type R-40A R-40A R-40A R-40A Refrigerant Charge Circuit 6.35 kg (4 lbs. 0 oz.) 4.76 kg (0 lbs. 8 oz.) 6.35 kg (4 lbs. 0 oz.) 6.58 kg (4 lbs. 8 oz.) Furnished Circuit 2 6.35 kg (4 lbs. 0 oz.) 4.76 kg (0 lbs. 8 oz.) 6.35 kg (4 lbs. 0 oz.) 6.58 kg (4 lbs. 8 oz.) Circuit 3 N/A 4.76 kg (0 lbs. 8 oz.) 6.35 kg (4 lbs. 0 oz.) 6.58 kg (4 lbs. 8 oz.) Gas Heating Options Available See page 2 Compressor Type (number) Scroll (2) Scroll (3) Scroll (3) Scroll (3) Outdoor Net face area (total) - m 2 (sq. ft.) 3.85 (4.4) 3.85 (4.4) 5.3 (55.2) 5.3 (55.2) Coils Tube diameter - mm (in.) 9.5 (3/8) 9.5 (3/8) 9.5 (3/8) 9.5 (3/8) Number of rows 2 2 2 2 Fins per m (Fins per inch) 787 (20) 787 (20) 787 (20) 787 (20) Outdoor Coil Fans Motor - (No.) W (HP) (3) 250 (/3) (3) 250 (/3) (4) 250 (/3) (4) 250 (/3) Motor rev/min 896 896 896 896 Total Motor watts 840 840 46 46 Diameter - (No.) mm (in.) (3) 60 (24) (3) 60 (24) (4) 60 (24) (4) 60 (24) Number of blades 3 3 3 3 Total Air volume - L/s (cfm) 4720 (0 000) 4720 (0 000) 6275 (3 300) 6275 (3 300) Indoor Coils Net face area (total) - m 2 (sq. ft.) 7.3 (8.60).99 (2.4).99 (2.4).99 (2.4) Tube diameter - mm (in.) 9.5 (3/8) 9.5 (3/8) 9.5 (3/8) 9.5 (3/8) Number of rows 3 3 3 3 Fins per m (Fins per inch) 55 (4) 55 (4) 55 (4) 55 (4) Drain connection - No. and size () in. FPT () in. FPT () in. FPT () in. FPT Expansion device type Balance port TXV, removable head 3 Indoor Nominal Motor kw (HP) 2.2 (3) 2.2 (3) 3.7 (5) 3.7 (5) Blower Maximum usable motor kw (HP) 2.6 (3.45) 2.6 (3.45) 4.3 (5.75) 4.3 (5.75) and Kit # (rev/min range) Kit (446-604) Kit (446-604) Kit 3 (57-72) Kit 3 (57-72) Drive Kit 2 (57-72) Kit 2 (57-72) Kit 4 (708-87) Kit 4 (708-87) Selection Kit 5 (788-988) Kit 5 (788-988) Nominal Motor kw (HP) 3.7 (5) 3.7 (5) 5.6 (7.5) 5.6 (7.5) Maximum usable motor kw (HP) 4.3 (5.75) 4.3 (5.75) 6.4 (8.6) 6.4 (8.6) Kit # (rev/min range) Kit 3 (57-72) Kit 3 (57-72) Kit 6 (708-87) Kit 6 (708-87) Kit 4 (708-87) Kit 4 (708-87) Kit 7 (788-988) Kit 7 (788-988) Kit 5 (788-988) Kit 5 (788-988) Kit 8 (87-07) Kit 8 (87-07) Nominal Motor kw (HP) 5.6 (7.5) 5.6 (7.5) 7.5 (0) 7.5 (0) Maximum usable motor kw (HP) 6.4 (8.6) 6.4 (8.6) 8.6 (.5) 8.6 (.5) Kit # (rev/min range) Kit 6 (708-87) Kit 6 (708-87) Kit 7 (788-988) Kit 7 (788-988) Kit 7 (788-988) Kit 7 (788-988) Kit 0 (87-07) Kit 0 (87-07) Kit 8 (87-07) Kit 8 (87-07) Kit (945-38) Kit (945-38) Blower wheel nominal diameter x width - mm (in.) (2) 38 x 38 (5 x 5) Filters Type of filter Fiberglass, disposable Number and size - mm (in.) (6) 60 x 60 x 5 (24 x 24 x 2) Electrical characteristics 380/420V - 50 hertz - 3 phase with neutral NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. Tested at conditions included in the USE certification program, which is based on AHRI Standard 340/360; 35 C (95 F) outdoor air temperature and 27 C (80 F) db/9 C (67 F) wb entering evaporator air; minimum external duct static pressure while operating at rated voltage and air volumes. 2 Integrated Energy Efficiency Ratio tested at conditions included in AHRI Standard 340/360 while operating at rated voltage and air volumes. 3 Using total air volume and system static pressure requirements determine from blower performance tables rev/min and motor output required. Maximum usable output of motors furnished are shown. See Belt Drive Specification Table for maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page

SPECIFICATIONS - GAS HEAT Usage Data Model Number KGA80 KGA20 KGA240 KGA300 Gas Heating Performance KGA80 KGA20 KGA240 KGA300 Heat Input Type Standard (S) Medium (M) High (H) Number of Gas Heat Stages 2 2 2 Input - kw (Btuh) First Stage 49.5 (69 000) 68.5 (234 000) 9.4 (32 000) Second Stage 68.5 (234 000) 9.9 (34 000) 23.0 (420 000) Output - kw (Btuh) First Stage - - - - - - - - - Recommended Gas Supply Pressure - kpa (in. w.g.) Second Stage 54.8 (87 000) 73.5 (25 000) 98.4 (336 000) Temperature Rise Range - C ( F) 8-25 (5-45) 7-33 (30-60) 22-39 (40-70) Thermal Efficiency 80.0% 80.0% 80.0% Gas Supply Connections in. npt in. npt in. npt Natural.7 (7).7 (7).7 (7) LPG/Propane 2.7 () 2.7 () 2.7 () HIGH ALTITUDE DERATE Units may be installed at altitudes up to 60 m (2000 feet) above sea level without any modification. At altitudes above 60 m (2000 feet), units must be derated to match gas manifold pressures shown in table below. NOTE - This is the only permissible derate for these units. Gas Heat Type Altitude - m (ft.) Standard (S) 6-372 (200-4500) Medium (M) 6-372 (200-4500) High (H) 6-372 (200-4500) Gas Manifold Pressure kpa (in. w.g.) Input Rate Natural Gas or LPG/Propane - kw (Btuh) Natural Gas LPG/Propane Gas First Stage Second Stage 0.3 (0.52) 0.45 (.82) 49.5 (69 000) 66 (225 000) 0.3 (0.52) 0.45 (.82) 68.5 (234 000) 88.7 (302 700) 0.3 (0.52) 0.45 (.82) 9.4 (32 000) 8.6 (404 800) Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 2

RATINGS NOTE - For Temperatures and Capacities not shown in tables, see bulletin - Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 52.8 kw - KGA80S4 (ST STAGE) Outdoor Air Temperature Entering Outdoor Coil Entering Total 8 C 24 C 29 C 35 C Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Temperature Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb L/s kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C 2265 25. 4.5.70.82.92 24.3 4.59.7.83.94 23.3 5.09.72.84.95 22.2 5.65.73.86.97 7 C 2830 26.5 4.22.74.87.99 25.5 4.67.75.88.00 24.4 5.6.76.90.00 23.3 5.7.78.92.00 3400 27.4 4.28.78.92.00 26.4 4.7.79.94.00 25.3 5.2.80.96.00 24. 5.77.82.98.00 2265 26.4 4.22.57.68.78 25.5 4.67.57.69.79 24.5 5.6.58.70.8 23.4 5.72.58.7.82 9 C 3400 27.8 4.30.59.7.84 26.8 4.74.59.73.85 25.7 5.24.60.74.87 24.6 5.80.6.75.89 3400 28.8 4.36.6.76.89 27.8 4.80.62.77.90 26.6 5.29.63.78.93 25.4 5.85.64.80.95 2265 27.7 4.30.43.55.65 26.7 4.74.44.55.66 25.7 5.24.45.56.67 24.6 5.80.44.57.68 22 C 2830 29.2 4.38.44.57.69 28. 4.82.45.58.70 27.0 5.32.45.59.72 25.8 5.88.45.59.73 3400 30.2 4.45.45.60.73 29. 4.88.45.60.75 27.9 5.38.45.62.76 26.7 5.94.46.63.78 52.8 kw - KGA80S4 (2ND STAGE) Outdoor Air Temperature Entering Outdoor Coil Entering Total 26.7 C 35 C 43.3 C 5.7 C Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Temperature Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb L/s kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C 2265 47. 0.05.74.87.98 44.0.73.76.89.00 40.6 3.74.78.93.00 36.8 6.8.82.97.00 7 C 2830 49.2 0.9.79.93.00 45.9.86.8.96.00 42.2 3.88.84.99.00 38.5 6.34.88.00.00 3400 50.8 0.30.83.98.00 47.4.97.86.00.00 43.9 4.0.89.00.00 40.2 6.48.94.00.00 2265 49.6 0.22.59.72.84 46.4.90.60.74.86 42.8 3.9.6.76.90 38.7 6.35.63.80.94 9 C 3400 5.8 0.37.6.76.90 48.3 2.04.63.79.93 44.4 4.04.65.82.97 40. 6.47.68.86.00 3400 53.4 0.47.64.8.96 49.6 2.3.66.84.99 45.6 4.4.69.87.00 4.0 6.56.72.92.00 2265 52.0 0.38.45.57.69 48.6 2.06.44.58.7 45.0 4.09.45.60.74 40.7 6.53.47.62.77 22 C 2830 54.3 0.54.45.60.74 50.7 2.2.46.62.77 46.7 4.23.47.64.80 42. 6.65.48.67.84 3400 56.0 0.66.47.63.79 52. 2.32.48.65.82 47.9 4.33.49.68.85 43. 6.75.50.7.90 6.5 kw - KGA20S4 (ST STAGE) Outdoor Air Temperature Entering Outdoor Coil Entering Total 8 C 24 C 29 C 35 C Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Temperature Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb L/s kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C 2645 38.9 6.65.73.86.98 37.4 7.35.74.87.99 35.9 8.2.75.89.00 34.2 8.97.77.9.00 7 C 3305 40.8 6.7.78.92.00 39.2 7.40.79.94.00 37.5 8.7.8.96.00 35.8 9.02.82.98.00 3965 42.2 6.75.82.98.00 40.6 7.44.84.99.00 38.9 8.2.85.00.00 37.2 9.06.87.00.00 2645 4. 6.72.58.7.83 39.6 7.4.59.72.84 38.0 8.8.59.73.86 36.3 9.03.60.74.88 9 C 3965 43. 6.78.6.75.89 4.5 7.47.6.77.9 39.8 8.23.62.78.93 37.9 9.09.63.80.95 3965 44.6 6.82.64.80.95 42.9 7.5.64.8.97 4.0 8.27.65.83.98 39.0 9.2.67.85.00 2645 43.3 6.78.44.57.68 4.7 7.47.44.57.69 40.0 8.24.45.58.70 38.3 9.0.44.59.72 22 C 3305 45.4 6.85.45.59.73 43.7 7.53.45.60.74 42.0 8.30.45.6.76 40.0 9.6.46.62.78 3965 47. 6.89.46.62.77 45.3 7.58.46.63.79 43.3 8.34.47.64.8 4.2 9.20.48.66.83 6.5 kw - KGA20S4 (2ND STAGE) Outdoor Air Temperature Entering Outdoor Coil Entering Total 26.7 C 35 C 43.3 C 5.7 C Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Temperature Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb L/s kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C 2645 54.2.68.76.90.00 50.5 3.56.78.93.00 46.3 5.77.8.97.00 4.6 8.39.86.00.00 7 C 3305 56.7.76.8.97.00 52.8 3.64.84.99.00 48.6 5.86.87.00.00 44.3 8.52.92.00.00 3965 58.6.82.86.00.00 55.0 3.7.89.00.00 5.0 5.96.93.00.00 46.2 8.6.98.00.00 2645 57.4.78.60.73.86 53.5 3.66.6.76.89 49. 5.89.63.79.93 44. 8.5.66.83.98 9 C 3965 60..86.63.79.93 55.8 3.75.65.82.97 5. 5.97.67.85.00 45.7 8.60.70.90.00 3965 6.9.92.66.84.99 57.4 3.80.68.87.00 52.5 6.03.7.9.00 47.0 8.66.74.96.00 2645 60.4.88.44.58.7 56.5 3.77.45.60.73 52.0 6.0.46.6.76 46.8 8.65.47.64.80 22 C 3305 63.3.97.45.6.76 58.9 3.86.46.63.79 54.0 6.0.48.66.83 48.5 8.73.49.69.87 3965 65.2 2.03.47.65.82 60.7 3.92.48.67.85 55.5 6.6.50.70.89 49.7 8.80.52.74.94 Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 3

RATINGS NOTE - For Temperatures and Capacities not shown in tables, see bulletin - Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 70.3 kw - KGA240S4 (ST STAGE) Outdoor Air Temperature Entering Outdoor Coil Entering Total 8 C 24 C 29 C 35 C Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Temperature Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb L/s kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C 3020 43.9 6.99.7.84.97 42.2 7.78.72.86.98 40.4 8.66.73.87.00 38.5 9.64.75.90.00 7 C 3775 46.0 7.05.76.9.00 44.2 7.84.77.93.00 42.3 8.72.79.95.00 40.3 9.70.8.98.00 4530 47.7 7.09.8.97.00 45.8 7.89.82.99.00 43.8 8.77.84.00.00 4.9 9.76.87.00.00 3020 46.6 7.06.57.69.8 44.7 7.86.57.70.82 42.8 8.74.57.7.84 40.8 9.72.59.73.86 9 C 4530 48.8 7.2.60.74.88 46.7 7.92.6.75.90 44.6 8.80.62.76.92 42.4 9.78.63.79.95 4530 50.3 7.6.63.78.94 48.2 7.97.64.80.97 46.0 8.85.64.82.99 43.7 9.83.66.84.00 3020 49.2 7.3.43.55.66 47.4 7.94.43.56.67 45.3 8.83.44.56.69 43.2 9.8.44.57.70 22 C 3775 5.5 7.20.44.58.7 49.4 8.0.45.59.73 47.2 8.90.45.60.74 44.9 9.87.46.62.76 4530 53.0 7.24.45.6.76 50.8 8.05.46.63.78 48.5 8.94.47.64.80 46.0 9.92.47.65.82 70.3 kw - KGA240S4 (2ND STAGE) Outdoor Air Temperature Entering Outdoor Coil Entering Total 26.7 C 35 C 43.3 C 5.7 C Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Temperature Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb L/s kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C 3020 6.9 2.43.75.90.00 57.7 4.59.78.94.00 53.0 7.0.8.98.00 48.0 9.99.85.00.00 7 C 3775 64.7 2.53.8.98.00 60.3 4.69.84.00.00 55.9 7.2.88.00.00 50.8 20.09.94.00.00 4530 67.2 2.62.87.00.00 63.0 4.80.90.00.00 58.3 7.3.95.00.00 52.9 20.7.00.00.00 3020 65.5 2.56.59.73.87 6.0 4.72.6.75.90 56.0 7.22.63.78.95 50.3 20.07.65.83.99 9 C 4530 68.2 2.66.63.79.95 63.2 4.8.64.82.99 57.8 7.30.67.86.00 5.9 20.3.69.9.00 4530 70.0 2.72.66.84.00 64.9 4.88.68.88.00 59.3 7.35.7.93.00 53.3 20.9.75.99.00 3020 69.2 2.69.44.57.70 64.4 4.86.45.60.73 59. 7.35.46.6.76 53. 20.7.47.64.80 22 C 3775 7.9 2.80.45.62.77 66.6 4.96.46.63.80 6.0 7.43.47.65.84 54.7 20.24.49.69.89 4530 73.7 2.86.46.65.83 68.3 5.02.48.68.86 62.5 7.49.49.70.9 56.0 20.30.5.75.97 88 kw - KGA300S4 (ST STAGE) Outdoor Air Temperature Entering Outdoor Coil Entering Total 8 C 24 C 29 C 35 C Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Temperature Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb L/s kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C 3775 52.3 9.5.72.85.97 50.4 0..73.87.99 48.3.8.74.88.00 46. 2.39.76.9.00 7 C 4720 54.8 9.3.77.92.00 52.8 0.27.79.94.00 50.5.34.80.96.00 48.2 2.55.82.98.00 5665 56.6 9.45.82.98.00 54.5 0.40.84.99.00 52.2.47.85.00.00 50.0 2.69.87.00.00 3775 55.4 9.36.58.70.82 53.4 0.3.58.7.83 5..39.59.72.85 48.8 2.60.60.73.87 9 C 5665 57.7 9.52.60.75.89 55.6 0.47.6.76.9 53.2.55.63.78.93 50.7 2.75.63.80.95 5665 59.3 9.64.64.79.95 57. 0.59.65.82.97 54.6.66.66.83.99 52.0 2.87.67.86.00 3775 58.4 9.57.44.56.68 56.3 0.53.44.57.69 53.9.6.44.57.70 5.4 2.82.45.58.7 22 C 4720 60.9 9.74.44.59.72 58.4 0.69.45.60.74 56..77.45.6.76 53.4 2.98.47.62.77 5665 62.6 9.87.46.63.77 60. 0.82.46.64.79 57.5.89.47.65.8 54.7 3.0.48.66.84 88 kw - KGA300S4 (2ND STAGE) Outdoor Air Temperature Entering Outdoor Coil Entering Total 26.7 C 35 C 43.3 C 5.7 C Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Cool Motor Ratio (S/T) Temperature Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb Cap. Input Dry Bulb L/s kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C kw kw 24 C 27 C 29 C 3775 74.8 6.7.76.9.00 70.0 8.83.79.94.00 64.5 22.05.82.98.00 58.5 25.93.86.00.00 7 C 4720 78. 6.42.82.98.00 72.8 9.08.85.00.00 67.6 22.33.89.00.00 6.8 26.29.94.00.00 5665 80.8 6.64.88.00.00 76.0 9.35.9.00.00 70.4 22.60.95.00.00 64. 26.54.00.00.00 3775 79.0 6.50.60.74.88 73.9 9.6.62.77.9 67.9 22.36.63.80.95 6.3 26.2.66.84.00 9 C 5665 8.9 6.72.64.80.96 76.3 9.38.65.83.99 70.0 22.56.68.87.00 63. 26.42.7.92.00 5665 84. 6.90.67.86.00 78.0 9.54.69.89.00 7.8 22.73.72.94.00 64.7 26.58.75.99.00 3775 83.2 6.83.45.58.7 77.8 9.5.45.60.74 7.6 22.70.46.62.77 64.7 26.60.47.65.8 22 C 4720 86.2 7.07.46.62.78 80.2 9.73.47.64.8 73.6 22.9.48.67.85 66.6 26.8.49.70.90 5665 88.4 7.24.48.66.84 82. 9.89.49.68.87 75.4 23.08.50.7.92 67.8 26.95.52.75.97 Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 4

BLOWER DATA BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL & AIR FILTERS IN PLACE FOR ALL UNITS ADD: - Wet indoor coil air resistance of selected unit. 2 - Any factory installed options air resistance (electric heat, economizer, etc.) 3 - Any field installed accessories air resistance (electric heat, duct resistance, diffuser, etc.) Then determine from blower table blower motor output and drive required. See for wet coil and option/accessory air resistance data. See for factory installed drive kit specifications. Air Volume TOTAL STATIC PRESSURE - Pa (Inches Water Gauge) 00 (0.40) 50 (0.60) 200 (0.80) 250 (.00) 300 (.20) 350 (.40) L/s cfm rev/ min kw BHP rev/ min kw BHP rev/ min kw BHP rev/ min kw BHP rev/ min kw BHP rev/ min kw BHP 890 4000 545 0.63 0.85 635 0.82.0 75.04.40 785.27.70 850.49 2.00 90.72 2.30 2005 4250 555 0.67 0.90 645 0.93.25 725.6.55 795.38.85 855.60 2.5 95.83 2.45 225 4500 565 0.75.00 655.0.35 730.23.65 800.49 2.00 865.75 2.35 925.98 2.65 2240 4750 575 0.82.0 660.08.45 740.34.80 80.60 2.5 870.86 2.50 930 2.3 2.85 2360 5000 585 0.93.25 670.9.60 750.45.95 85.72 2.30 880 2.0 2.70 940 2.27 3.05 2480 5250 595.0.35 680.27.70 755.57 2.0 825.86 2.50 890 2.6 2.90 945 2.42 3.25 2595 5500 605.08.45 690.38.85 765.68 2.25 835.98 2.65 895 2.27 3.05 955 2.57 3.45 275 5750 65.9.60 700.49 2.00 775.83 2.45 840 2.3 2.85 905 2.42 3.25 960 2.72 3.65 2830 6000 630.30.75 70.60 2.5 785.94 2.60 850 2.27 3.05 90 2.57 3.45 970 2.9 3.90 2950 6250 640.42.90 720.75 2.35 795 2.09 2.80 860 2.42 3.25 920 2.76 3.70 975 3.09 4.5 3070 6500 650.53 2.05 730.86 2.50 805 2.24 3.00 870 2.57 3.45 930 2.95 3.95 985 3.28 4.40 385 6750 665.64 2.20 745 2.0 2.70 85 2.39 3.20 880 2.76 3.70 940 3.3 4.20 995 3.47 4.65 3305 7000 675.75 2.35 755 2.6 2.90 825 2.54 3.40 890 2.95 3.95 950 3.32 4.45 005 3.69 4.95 3420 7250 690.94 2.60 765 2.3 3.0 835 2.72 3.65 900 3.09 4.5 955 3.47 4.65 05 3.9 5.25 3540 7500 700 2.05 2.75 775 2.46 3.30 845 2.87 3.85 90 3.32 4.45 965 3.69 4.95 020 4.0 5.50 3660 7750 75 2.24 3.00 790 2.65 3.55 855 3.06 4.0 920 3.50 4.70 975 3.9 5.25 030 4.33 5.80 3775 8000 725 2.39 3.20 800 2.83 3.80 865 3.24 4.35 930 3.69 4.95 985 4.0 5.50 040 4.55 6.0 3895 8250 740 2.54 3.40 80 2.98 4.00 880 3.47 4.65 940 3.9 5.25 995 4.36 5.85 050 4.8 6.45 400 8500 750 2.72 3.65 825 3.2 4.30 890 3.65 4.90 950 4.4 5.55 005 4.59 6.5 060 5.07 6.80 430 8750 765 2.9 3.90 835 3.39 4.55 900 3.88 5.20 960 4.36 5.85 05 4.8 6.45 070 5.33 7.5 4250 9000 780 3.3 4.20 850 3.62 4.85 90 4.0 5.50 970 4.59 6.5 025 5.07 6.80 080 5.59 7.50 4365 9250 790 3.32 4.45 860 3.84 5.5 925 4.36 5.85 985 4.88 6.55 040 5.37 7.20 090 5.85 7.85 4485 9500 805 3.54 4.75 875 4.06 5.45 935 4.59 6.5 995 5.5 6.90 050 5.67 7.60 00 6.5 8.25 4600 9750 820 3.77 5.05 885 4.29 5.75 950 4.88 6.55 005 5.37 7.20 060 5.93 7.95 0 6.45 8.65 4720 0,000 835 4.03 5.40 900 4.59 6.5 960 5. 6.85 05 5.67 7.60 070 6.23 8.35 20 6.75 9.05 4835 0,250 845 4.2 5.65 90 4.8 6.45 970 5.37 7.20 030 5.97 8.00 080 6.52 8.75 35 7.2 9.55 4955 0,500 860 4.47 6.00 925 5. 6.85 985 5.70 7.65 040 6.26 8.40 095 6.86 9.20 45 7.46 0.00 5075 0,750 875 4.77 6.40 940 5.4 7.25 000 6.00 8.05 055 6.60 8.85 05 7.20 9.65 55 7.79 0.45 590,000 890 5.07 6.80 950 5.67 7.60 00 6.30 8.45 065 6.94 9.30 5 7.49 0.05 65 8.3 0.90 CONTINUED ON NEXT PAGE Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 5

BLOWER DATA BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL & AIR FILTERS IN PLACE FOR ALL UNITS ADD: - Wet indoor coil air resistance of selected unit. 2 - Any factory installed options air resistance (electric heat, economizer, etc.) 3 - Any field installed accessories air resistance (electric heat, duct resistance, diffuser, etc.) Then determine from blower table blower motor output and drive required. See for wet coil and option/accessory air resistance data. See for factory installed drive kit specifications. Air Volume TOTAL STATIC PRESSURE - Pa (Inches Water Gauge) 400 (.60) 450 (.80) 500 (2.00) 550 (2.20) 600 (2.40) 650 (2.60) L/s cfm rev/ min kw BHP rev/ min kw BHP rev/ min kw BHP rev/ min kw BHP rev/ min kw BHP rev/ min kw BHP 890 4000 965.94 2.60 020 2.6 2.90 070 2.42 3.25 5 2.65 3.55 60 2.87 3.85 205 3.09 4.5 2005 4250 970 2.09 2.80 025 2.3 3.0 075 2.57 3.45 20 2.80 3.75 65 3.06 4.0 20 3.32 4.45 225 4500 980 2.24 3.00 030 2.46 3.30 080 2.72 3.65 30 3.02 4.05 75 3.24 4.35 25 3.50 4.70 2240 4750 985 2.39 3.20 040 2.65 3.55 085 2.9 3.90 35 3.7 4.25 80 3.47 4.65 225 3.73 5.00 2360 5000 995 2.54 3.40 045 2.83 3.80 095 3.09 4.5 40 3.36 4.50 85 3.65 4.90 230 3.95 5.30 2480 5250 000 2.72 3.65 050 2.98 4.00 00 3.28 4.40 50 3.58 4.80 95 3.88 5.20 235 4.8 5.60 2595 5500 00 2.87 3.85 060 3.7 4.25 0 3.50 4.70 55 3.80 5.0 200 4.0 5.50 240 4.40 5.90 275 5750 05 3.06 4.0 065 3.36 4.50 5 3.69 4.95 60 3.99 5.35 205 4.33 5.80 250 4.66 6.25 2830 6000 025 3.24 4.35 075 3.58 4.80 20 3.88 5.20 70 4.2 5.65 25 4.55 6.0 255 4.88 6.55 2950 6250 030 3.43 4.60 080 3.77 5.05 30 4.0 5.50 75 4.44 5.95 220 4.8 6.45 265 5.5 6.90 3070 6500 040 3.62 4.85 090 3.99 5.35 40 4.36 5.85 85 4.70 6.30 225 5.03 6.75 270 5.4 7.25 385 6750 045 3.80 5.0 095 4.8 5.60 45 4.55 6.0 90 4.92 6.60 235 5.29 7.0 275 5.67 7.60 3305 7000 055 4.03 5.40 05 4.44 5.95 55 4.8 6.45 200 5.8 6.95 240 5.56 7.45 285 5.97 8.00 3420 7250 065 4.29 5.75 5 4.66 6.25 60 5.03 6.75 205 5.44 7.30 250 5.85 7.85 290 6.23 8.35 3540 7500 075 4.5 6.05 25 4.92 6.60 70 5.33 7.5 25 5.70 7.65 260 6.5 8.25 300 6.52 8.75 3660 7750 080 4.74 6.35 30 5.5 6.90 80 5.59 7.50 225 6.00 8.05 265 6.4 8.60 305 6.82 9.5 3775 8000 090 5.00 6.70 40 5.4 7.25 85 5.85 7.85 230 6.26 8.40 275 6.7 9.00 35 7.6 9.60 3895 8250 00 5.26 7.05 50 5.70 7.65 95 6.5 8.25 240 6.60 8.85 280 7.0 9.40 325 7.49 0.05 400 8500 0 5.52 7.40 60 6.00 8.05 205 6.45 8.65 250 6.90 9.25 290 7.35 9.85 330 7.79 0.45 430 8750 20 5.78 7.75 65 6.23 8.35 25 6.75 9.05 255 7.20 9.65 300 7.68 0.30 340 8.3 0.90 4250 9000 30 6.08 8.5 75 6.52 8.75 220 7.0 9.40 265 7.53 0.0 30 8.05 0.80 350 8.50.40 4365 9250 40 6.38 8.55 85 6.86 9.20 230 7.35 9.85 275 7.87 0.55 35 8.35.20 - - - - - - - - - 4485 9500 50 6.67 8.95 95 7.6 9.60 240 7.68 0.30 285 8.24.05 - - - - - - - - - - - - - - - - - - 4600 9750 60 7.0 9.40 205 7.49 0.05 250 8.05 0.80 295 8.58.50 - - - - - - - - - - - - - - - - - - 4720 0 000 70 7.3 9.80 25 7.83 0.50 260 8.39.25 - - - - - - - - - - - - - - - - - - - - - - - - - - - 4835 0 250 80 7.64 0.25 225 8.20.00 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4955 0 500 90 7.98 0.70 235 8.54.45 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5075 0 750 200 8.35.20 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 590 000 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 6

BLOWER DATA FACTORY INSTALLED BELT DRIVE KIT SPECIFICATIONS Nominal kw Nominal hp Maximum kw Maximum hp Drive Kit Number Rev/min Range 2.2 3 2.6 3.45 446-604 2.2 3 2.6 3.45 2 57-72 3.7 5 4.3 5.75 3 57-72 3.7 5 4.3 5.75 4 708-87 3.7 5 4.3 5.75 5 788-988 5.6 7.5 6.4 8.63 6 708-87 5.6 7.5 6.4 8.63 7 788-988 5.6 7.5 6.4 8.63 8 87-07 7.5 0 8.6.50 7 788-988 7.5 0 8.6.50 0 87-07 7.5 0 8.6.50 945-38 NOTE - Using total air volume and system static pressure requirements determine from blower performance tables rev/min and motor output required. Maximum usable output of motors furnished are shown. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. FACTORY INSTALLED OPTIONS/FIELD INSTALLED ACCESSORY AIR RESISTANCE Air Volume Wet Indoor Coil 80 L/s cfm Pa in. w.g. Pa 20, thru 300 in. w.g. Low/ Standard Heat Pa Gas Heat Exchanger in. w.g. Medium Heat Pa in. w.g. Pa High Heat in. w.g. Economizer Filters MERV 8 MERV 3 80 thru 240 Horizontal Roof Curb 890 4000 5 0.02 0 0.04 0 0.04 5 0.06 - - - - - - - - - - - - 0 0.04 5 0.06 5 0.06 - - - - - - 2005 4250 5 0.02 0 0.04 0 0.04 5 0.06 - - - - - - - - - - - - 0 0.04 5 0.06 7 0.07 - - - - - - 225 4500 5 0.02 2 0.05 2 0.05 7 0.07 22 0.09 - - - - - - 0 0.04 7 0.07 7 0.07 5 0.02 2240 4750 5 0.02 2 0.05 2 0.05 20 0.08 25 0.0 - - - - - - 0 0.04 7 0.07 20 0.08 7 0.03 2360 5000 5 0.02 2 0.05 2 0.05 22 0.09 27 0. - - - - - - 2 0.05 7 0.07 20 0.08 7 0.03 2475 5250 5 0.02 5 0.06 5 0.06 25 0.0 30 0.2 - - - - - - 2 0.05 7 0.07 22 0.09 0 0.04 2595 5500 5 0.02 7 0.07 5 0.06 25 0.0 32 0.3 - - - - - - 2 0.05 7 0.07 25 0.0 0 0.04 275 5750 7 0.03 7 0.07 5 0.06 27 0. 35 0.4 - - - - - - 2 0.05 20 0.08 27 0. 2 0.05 2830 6000 7 0.03 20 0.08 7 0.07 30 0.2 37 0.5 - - - - - - 2 0.05 20 0.08 27 0. 5 0.06 2950 6250 7 0.03 20 0.08 7 0.07 30 0.2 40 0.6 2 0.0 2 0.05 20 0.08 30 0.2 7 0.07 3065 6500 7 0.03 22 0.09 20 0.08 32 0.3 42 0.7 5 0.02 2 0.05 20 0.08 32 0.3 20 0.08 385 6750 0 0.04 25 0.0 20 0.08 35 0.4 45 0.8 7 0.03 2 0.05 20 0.08 35 0.4 20 0.08 3305 7000 0 0.04 25 0.0 22 0.09 37 0.5 47 0.9 0 0.04 5 0.06 20 0.08 37 0.5 22 0.09 3420 7250 0 0.04 27 0. 22 0.09 40 0.6 50 0.20 2 0.05 5 0.06 22 0.09 40 0.6 25 0.0 3540 7500 2 0.05 30 0.2 25 0.0 42 0.7 52 0.2 5 0.06 5 0.06 22 0.09 42 0.7 27 0. 3775 8000 2 0.05 32 0.3 27 0. 47 0.9 60 0.24 22 0.09 5 0.06 22 0.09 47 0.9 32 0.3 400 8500 5 0.06 37 0.5 30 0.2 50 0.20 65 0.26 27 0. 5 0.06 22 0.09 52 0.2 37 0.5 4245 9000 7 0.07 40 0.6 32 0.3 57 0.23 72 0.29 35 0.4 7 0.07 25 0.0 60 0.24 42 0.7 4485 9500 20 0.08 45 0.8 35 0.4 62 0.25 80 0.32 40 0.6 7 0.07 25 0.0 65 0.26 47 0.9 4720 0 000 20 0.08 50 0.20 40 0.6 67 0.27 87 0.35 47 0.9 7 0.07 27 0. 72 0.29 52 0.2 4955 0 500 22 0.09 55 0.22 42 0.7 75 0.30 94 0.38 55 0.22 7 0.07 27 0. 77 0.3 60 0.24 59 000 27 0. 60 0.24 45 0.8 77 0.3 99 0.40 62 0.25 20 0.08 27 0. 85 0.34 67 0.27 Pa in. w.g. Pa in. w.g. Pa in. w.g. Pa in. w.g. Pa 300 in. w.g. Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 7

BLOWER DATA POWER EXHAUST FAN PERFORMANCE Return Air System Static Pressure Air Volume Exhausted Pa in. w.g. L/s cfm 0 0.00 3395 795 2 0.05 3230 6845 25 0.0 3040 6440 37 0.5 2795 5925 50 0.20 2545 5395 62 0.25 2275 4820 75 0.30 990 425 87 0.35 690 3580 00 0.40 380 2925 2 0.45 055 2235 25 0.50 725 535 CEILING DIFFUSER AIR RESISTANCE Step-Down Diffuser Flush Diffuser Air RTD-85 RTD-275 Volume Side/2 Ends All Ends & Side/2 Ends All Ends & FD-85 FD-275 2 Ends Open 2 Ends Open Open Sides Open Open Sides Open L/s cfm Pa in. w.g. Pa in. w.g. Pa in. w.g. Pa in. w.g. Pa in. w.g. Pa in. w.g. Pa in. w.g. Pa in. w.g. 2360 5000 27 0.5 09 0.44 97 0.39 - - - - - - - - - - - - - - - - - - 67 0.27 - - - - - - 2455 5200 39 0.56 9 0.48 04 0.42 - - - - - - - - - - - - - - - - - - 75 0.30 - - - - - - 2550 5400 52 0.6 29 0.52 2 0.45 - - - - - - - - - - - - - - - - - - 82 0.33 - - - - - - 2645 5600 64 0.66 39 0.56 9 0.48 - - - - - - - - - - - - - - - - - - 90 0.36 - - - - - - 2735 5800 77 0.7 47 0.59 27 0.5 - - - - - - - - - - - - - - - - - - 97 0.39 - - - - - - 2830 6000 89 0.76 57 0.63 37 0.55 90 0.36 77 0.3 67 0.27 04 0.42 72 0.29 2925 6200 99 0.80 69 0.68 47 0.59 - - - - - - - - - - - - - - - - - - 4 0.46 - - - - - - 3020 6400 24 0.86 79 0.72 57 0.63 - - - - - - - - - - - - - - - - - - 24 0.50 - - - - - - 3065 6500 - - - - - - - - - - - - - - - - - - 04 0.42 90 0.36 77 0.3 - - - - - - 85 0.34 35 6600 229 0.92 9 0.77 67 0.67 - - - - - - - - - - - - - - - - - - 34 0.54 - - - - - - 320 6800 246 0.99 206 0.83 79 0.72 - - - - - - - - - - - - - - - - - - 44 0.58 - - - - - - 3305 7000 256.03 26 0.87 89 0.76 22 0.49 02 0.4 90 0.36 54 0.62 99 0.40 3400 7200 27.09 229 0.92 99 0.80 - - - - - - - - - - - - - - - - - - 64 0.66 - - - - - - 3490 7400 286.5 24 0.97 209 0.84 - - - - - - - - - - - - - - - - - - 74 0.70 - - - - - - 3540 7500 - - - - - - - - - - - - - - - - - - 27 0.5 4 0.46 02 0.4 - - - - - - 2 0.45 3585 7600 298.20 254.02 29 0.88 - - - - - - - - - - - - - - - - - - 84 0.74 - - - - - - 3775 8000 - - - - - - - - - - - - - - - - - - 47 0.59 22 0.49 07 0.43 - - - - - - 24 0.50 400 8500 - - - - - - - - - - - - - - - - - - 72 0.69 44 0.58 24 0.50 - - - - - - 42 0.57 4245 9000 - - - - - - - - - - - - - - - - - - 96 0.79 67 0.67 44 0.58 - - - - - - 64 0.66 4485 9500 - - - - - - - - - - - - - - - - - - 22 0.89 86 0.75 62 0.65 - - - - - - 84 0.74 4720 0 000 - - - - - - - - - - - - - - - - - - 249.00 209 0.84 82 0.73 - - - - - - 20 0.8 4955 0 500 - - - - - - - - - - - - - - - - - - 274.0 229 0.92 99 0.80 - - - - - - 22 0.89 590 000 - - - - - - - - - - - - - - - - - - 30.2 25.0 29 0.88 - - - - - - 239 0.96 CEILING DIFFUSER AIR THROW DATA Air Volume Effective Throw Range Air Volume Effective Throw Range Model No. L/s cfm RTD-85 Step-Down FD-85 Flush Model No. L/s cfm RTD-85 Step-Down FD-85 Flush m ft. m ft. m ft. m ft. 2645 5600 2-5 39-49 9-28 - 37 3400 7200 0-2 33-38 8-26 - 35 2735 5800 3-6 42-5 9-2 29-38 3490 7400-2 35-40 9-28 - 37 56 2830 6000 3-6 44-54 2-5 40-50 3585 7600-2 36-4 9-29 - 38 80 2925 6200 4-7 45-55 3-6 42-5 20 3680 7800 2-3 38-43 2-5 40-50 3020 6400 4-7 46-55 3-6 43-52 240 3775 8000 2-3 39-44 3-6 42-5 35 6600 4-7 47-56 4-7 45-56 300 3870 8200 2-4 4-46 3-6 43-52 Throw is the horizontal or vertical distance an airstream travels on leaving the 3965 8400 3-5 43-49 3-6 44-54 outletor diffuser before the maximum velocity is reduced to 5 m (50 ft.) per minute. Four sides open. 4060 8600 3-5 44-50 4-7 46-57 455 8800 4-7 47-55 5-8 48-59 Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 8

ELECTRICAL DATA KGA80S4 KGA20S4 KGA240S4 KGA300S4 Voltage - 50hz - 3 phase with neutral 380/4230V 380/4230V 380/4230V 380/4230V Compressor Rated Load Amps 2.2 9.7 0.6 2.2 Locked Rotor Amps 0 64 74 0 Compressor 2 Rated Load Amps 2.2 9.7 0.6 2.2 Locked Rotor Amps 0 64 74 0 Compressor 3 Rated Load Amps - - - 9.7 0.6 2.2 Outdoor Fan Motors Power Exhaust With (2) 0.25 kw (0.33 HP) Indoor Blower Motor Maximum Overcurrent Protection 2 Minimum Circuit Ampacity Locked Rotor Amps - - - 64 74 0 Number of motors 2 3 4 4 Full Load Amps.3.3.3.3 (total) (2.6) (3.9) (5.2) (5.2) Full Load Amps.3.3.3.3 (total) (2.6) (2.6) (2.6) (2.6) kw 2.2 3.7 5.6 2.2 3.7 5.6 3.7 5.6 7.5 3.7 5.6 7.5 Full Load Amps 5 7.8.8 5 7.8.8 7.8.8 5.2 7.8.8 5.2 Unit Only 45 50 50 50 50 50 50 60 70 60 60 70 With (2) 0.25 kw (0.33 HP) Power Exhaust 50 50 50 50 50 60 60 60 70 60 70 70 Unit Only 37 40 44 4 44 49 48 52 57 53 57 6 With (2) 0.25 kw (0.33 HP) Power Exhaust Extremes of operating range are plus and minus 0% of line voltage. 2 Heating / Air Conditioning / Refrigeration (HACR) type breaker or fuse. 3 Refer to local codes to determine wire, fuse and disconnect size requirements. 39 42 46 44 46 5 5 55 59 56 60 64 Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 9

UNIT CLEARANCES - MM (INCHES) Unit With Economizer OUTDOOR AIR HOOD C D B A Note: 240-300 sizes shown Unit Clearance A B C D Top Clearance mm in. mm in. mm in. mm in. Service Clearance 524 60 94 36 94 36 676 66 Clearance to Combustibles 94 36 25 25 25 Minimum Operation Clearance 43 45 94 36 94 36 04 4 Unobstructed NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. Service Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 20

OPTIONAL CONVENTIONAL TEMPERATURE CONTROL SYSTEMS - FIELD INSTALLED COMMERCIAL TOUCHSCREEN THERMOSTAT Intuitive Touchscreen Interface - Two Stage Heating / Two Stage Cooling Conventional or Heat Pump - Seven Day Programmable - Four Time Periods/ Day - Economizer Output - Title 24 Compliant - ENERGY STAR Qualified - Backlit Display - Automatic Changeover C0STAT02AEL (4W8) Sensors For Touchscreen Thermostat Remote non-adjustable wall mount 20k temperature sensor... C0SNZN0AE2- (47W36) Remote non-adjustable wall mount 0k averaging temperature sensor... C0SNZN73AE- (47W37) Outdoor temperature sensor... Accessories For Touchscreen Thermostat Locking cover (clear)... Remote sensors for C0STAT02AEL can be applied in the following combinations: () C0SNZN0AE-, (2) C0SNZN73AE-, (2) C0SNZN0AE- and () C0SNZN73AE-, (4) C0SNZN0AE-, (3) C0SNZN0AE- and (2) C0SNZN73AE. DIGITAL NON-PROGRAMMABLE THERMOSTATS Intuitive Interface - Automatic Changeover - Simple Up and Down Temperature Control Two-stage heating / cooling conventional systems... Sensor For Digital Non-Programmable Thermostats Above Remote wall mounted temperature sensor... (9L22) (X448) (39P2) C0STAT0AEL (3K98) (26K57) Intuitive Interface - Automatic Changeover - Backlit Display - Simple Up and Down Temperature Control One-stage heating / cooling conventional systems... Sensor For Digital Non-Programmable Thermostats Above Outdoor temperature sensor... Accessories For Digital Non-Programmable Thermostats Above Optional wall mounting plate... C0STAT2AEL (5M32) (X2658) Remote non-adjustable duct mount temperature sensor... C0SNDC00AE- C0SNSR03AE- C0MISC5AE- C0SNZN00AE- C0SNSR04AE- C0MISC7AE- (X2659) OUTDOOR SOUND DATA Unit Model Number Octave Band Sound Power Levels dba, re 0-2 Watts Center Frequency - HZ 25 250 500 000 2000 4000 8000 Sound Rating Number (db) 80, 20 7 78 8 8 76 7 63 86 240, 300 80 83 87 88 84 80 7 93 Note - The octave sound power data does not include tonal corrections. Sound Rating Number according to AHRI Standard 370-200. Landmark Packaged Gas / Electric 52.8 to 88 kw 50hz / Page 2