SIARGO MEMS FLOW SENSING PRODUCTS MEMS Mass Flow/Clog Sensors VC Siargo Ltd. ISO 9001 ISO OHSAS 18001

Similar documents
Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Airflow Sensors Line Guide

Duct Mount. Installation Instructions

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

Airflow Sensors Line Guide

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

WARNING MISUSE OF DOCUMENTATION

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL


AFA 500 FUME HOOD ALARMS

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

Item Symbol Rating Unit Power supply V CC 12.0 VDC Output voltage V OUT 3.0 VDC

installation instructions Fan Tray System FTA-3/FTA-6

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Alnor AirGard 410HE Air Flow Monitor for Hazardous Environment Fume Hoods

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Preamplifier Power Supply PPS-02 user's guide

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

RK Carbon Monoxide Transmitter Operator s Manual

Duct Humidity/Temp Sensor

HIH-4000 Series Humidity Sensors

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy 20 SLPM or 200 SLPM

Force Sensors Line Guide

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

HM1500LF Relative Humidity Module

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

INSTRUCTIONS PARTS LIST For President, Monark, Standard, and Fast-Flo Pumps, and Agitator

Installation Instructions for the

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

HIH-4030/31 Series Humidity Sensors

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

RK-02 Multi Point Detector Operator s Manual

Room Humidity/Temp Sensor

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

HIH-4010/4020/4021 Series Humidity Sensors

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

MEMS THERMAL MASS FLOW METERS FOR HUMIDIFIED GASES

Environmental Monitoring SmartSlot Card

HIH-4602-L Series Humidity Sensors

RK Hydrogen Sulfide Transmitter Operator s Manual

Static Pressure Alarm For Hazardous Location Fume Hoods

Humidity Monitor model 01080

EQUIPMENT Operation Manual

SCHMIDT LED Measured Value Display MD Instructions for Use

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

RK/ RK Oxygen Detector Operator s Manual

FUME HOOD MONITOR ALNOR AIRGARD 200

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Ultrasonic Reflective Sensor

RK Carbon Monoxide Transmitter Operator s Manual

FSS-SMT Series. Low Profile Force Sensor

RK-05 Carbon Monoxide Detector Operator s Manual

RK Transmitter Technical Notice

Model OEM-2 INSTRUCTIONS FOR USE

Installation/Operation Instructions COMP-COOL50/COMP-COOL50P 50 CFM COMPONENT COOLERS

RK Combustible Gas Transmitter Operator s Manual

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

RK CO 2 Transmitter Operator s Manual

1/24/01 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

HIH-5030/5031 Series Low Voltage Humidity Sensors

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

Cable Actuated Sensor Industrial Incremental Encoder Output

Isolated Thermocouple Module

RK Carbon Monoxide Transmitter Operator s Manual

Controllers. Instruction Manual WARNING

Potential Applications

Heater Installation Kit

EQUIPMENT Operation Manual

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

PodView Level Indicator LI40 Series Manual

3M Benchtop Air Ionizer 963E. User s Guide

Model Number Structure

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

RK / RK Methane Detector Operator s Manual

Application Note Honeywell Zephyr Analog and Digital Airflow Sensors: HAF Series-High Accuracy, ±50 SCCM to ±750 SCCM

Instruction Manual WARNING

Transcription:

Model FS7002 SIARGO MEMS FLOW SENSING PRODUCTS MEMS Mass Flow/Clog Sensors VC.4 ISO 9001 ISO 14001 OHSAS 18001 2016 Siargo Ltd.

FS7002 Series User Manual Document No. 05-2016-S6 EN Issue date: 201605. Revision: VC.4 Siargo Ltd. 3100 De La Cruz Boulevard, Suite 210, Santa Clara, CA 95054 USA Tel: +1(408)969.0368 Email: info@ siargo. com Copyright 2016 by Siargo Ltd. Siargo Ltd. and its subsidiaries reserve the rights to change the specifications and/ or descriptions without prior notice. For further information and updates, please visit: www.siargo.com

MEMS Mass Flow/Clog Sensors Model FS7002 Features Mass flow range up to 0 ~ 10 m/s Fast response time High sensitivity Cost effective Small form factor, easy installation Fully customizable Description The FS7002 mass flow/clog sensors are designed and manufactured using Siargo's proprietary MEMS flow sensor and package technology. The sensors with a fast response time of 20 msec are specially designed for the applications in open space air mass flow measurement or for monitoring the air flow status behind any air filters preventing clogging of the same. The air flow passing through the sensor via a specially designed venturi channel to provide the stability of the air flow for the measurement. The packaging enclosure is made of the chemically inert and thermally stable polycarbonate material. The compact design of the sensors also provide easy installation and minimum blockage in the air pathway where it is to be installed. Typical applications include but not limited to clog sensing in an intelligent air filter in an LCD projector, a filter clog monitoring in an air fresher, a ventilation duct flow profile, or a fan motor status. The FS7002 requires a power supply of 5 ± 5% Vdc and provides an analog output of 0.5 ~ 2.9 Vdc (typical) corresponding to the flow speed from 0 to full scale. Working Principle The MEMS sensor chip utilizes the calorimetric principle. It is packaged on a plate installed inside the flow channel, which provides additional flow conditioning from the boundary layer configuration resulting in a laminar flow. The mass flow measurement is established as the gas carries heat away from the heater leading to the redistribution of the temperature field. Accurate flow rate is obtained by calibration with standard gas at preset conditions. Flow direction Time-averaged velocity profile boundary layer Free stream Laminar Turbulent Sensor www.siargo.com FS7002 (VC.4) 1/5

1. Sensor Performance 1.1 Performance Specifications All data unless otherwise noted apply for measurement conditions: air, 20 C, 101.325 kpa absolute pressure, in a fixed flow channel of 8mm in diameter. Model FS7002-B FS7002-C Flow range 0~ 5 0 ~ 10 m/s Repeatability ± 3 ± 2 %FS Response Time 20 ms Output Non-linear, Analog Null Output 1 0.2 ~ 0.8 Vdc Full Scale Output 1 2.5 ~ 3.3 Vdc Power Supply 5 ± 5% Vdc Operating Current 2 < 10 ma Power Consumption < 50 mw Output Load Sourcing: 14; Sinking: 11 ma Pins Out 3 Pin, 2.54 mm centers, 0.635 mm square Working Temperature -10 ~ +70 Storage Temperature -20 ~ +80 Humidity < 95 %RH(No icing or condensation) 1 To obtain accurate flow measurement, let the sensor warm up 1 minute at power up. 2 The operating current is measured at 5.0 V supply without output load. o C o C 1.2 Flow Characteristics The FS7002 provides a non-linear analog output corresponding with 0 ~ full scale flow speed. The typical output characteristics of FS7002-B illustrated in Figure 1.1. The data are obtained at 5.0 Vdc supply. 3500 3000 2500 Output Voltage ( mv) Typical Output Curve - FS7002-B 2000 1500 1000 500 0 Flow Rate ( m/s) 1 2 3 4 5 Figure 1.1: The typical analog output curve of FS7002-B. www.siargo.com FS7002 (VC.4) 2/5

2. Electrical Interface 2.1 Pin Definition The FS7002 provides a 3-pin electrical interface. The sensor pin configuration is shown in Figure 2.1. 2.2 Pin Description Flow Direction 1 ---- VCC 2 ---- Vout 3 ---- GND Figure 2.1: FS7002 pin configuration. VCC and GND: The FS7002 requires a power supply of 5±5% Vdc. The voltage is internally filtered and regulated to power the circuit. The sensor output is dependent on the accuracy of the power supply and the ±5% power accuracy will ensure the performance. The sensor consumes less than 10 ma normally but the minimum supply current must be larger than 10 ma for stable performance. Vout: The analog output pin. 4. Application Notes (1) The typical output curves are obtained from the measurement of the sensor for air flow at 20 C, 101.325 kpa in a flow channel of 8mm in diameter. For applications deviated from these conditions, the performance may vary depending on the specific installation and environments; (2) For applications where the sensor is placed in an open air space, the sensor measures the air flow passing through the channel inside the sensor, which is best used as a flow switch or local flow speed indicator; (3)Temperature variations may lead to accuracy deviation from the original manufacture specifications when no temperature compensation is implemented in the electronics. In the worst case, the deviation could be as much as 0.3 %/ C; ( 4) Pressure variations would usually not result in any change for the sensor performance; (5) Humidity variations would usually not deteriorate the sensor performance unless condensation occurs. 3. Mechanical Dimensions and Mountings The FS7002 provides two mounting holes for easy installation. Be sure to align the arrow mark (on the sensor body) with the measurement flow direction. The sensor dimensions are shown in Figure 3.1. 5. Ordering Contact and Customer Support The sales offices are listed at the end of this document. For small quantities, the order can be placed either through website: www.siargo.com or the convenient sales office. For large quantities, please contact the sales office or distributors or sales representatives. Siargo is making every effort to ensure the quality of the products. In case of questions, and or product supports, please contact customer service listed at the end of the document. We will respond your request in a timely fashion and will work with you toward your complete satisfaction. Figure 3.1: The FS7002 mechanical dimensions. www.siargo.com FS7002 (VC.4) 3/5

Important Notices Wetted Materials and Compatibility The sensor body is made of medical compatible plastics. The sensor chip comprises of silicon, silicon nitride and silicon dioxide and the sensor chip surfaces are passivated with silicon nitride and silicon dioxide. The electronic sealing is provided by RTV (room temperature vulcanizing) silicone sealant WR-704 composed of HOCH (SiO) CH H. 3 n 3 Cautions for Handling and Installations The product at the time of shipment is fully inspected for product quality and meets all safety requirements. Additional safety measures during handling and installation should be applied. To prevent ESD (electrostatic discharge) damage and /or degradation, take customary and statutory ESD precautions when handling. Do power the product with the correct polarity, voltage and amperage. All precautions and measures for electrical voltage handling must apply. This product contains no user serviceable components. Do not attempt to disassemble, substitute parts or perform unauthorized modifications to the product. Doing so will forfeit the terms of the warranty and cause the liability to any damages thereafter. It should only be serviced by authorized personnel. Upon requests, Siargo will provide necessary technical support and/or training of the personnel. Cautions for Product Applications The product is designed for use with general purpose gases such as air and nitrogen. It is advised that the products are best used for non-explosive clean gases. The sensors cannot be used for gas metrology of fluoride or fluoride-containing gases. For updates of the product certification information, please contact the manufacturer. Use for other gases such as extreme corrosive and toxic gases may cause the product malfunctioning or even severe damages. Don't expose the product's outer surface to any liquids, the unit does not have a water resistive electronics package. Don't flow gas in conditions that can cause condensing water vapor to be trapped inside the unit as the accuracy could be significantly altered. It is suggested to design your application so that nominal flow rate is approximately 70% of the full scale flow rate of the sensor. Don't use a sensor with an extreme flow range, for instance, don't use a 10 m/s sensor for a 0.2 m/s application. Warranty and Liability (effective June 2009) Siargo warrants the products sold hereunder, properly used and properly installed under normal circumstances and service as described in the user manual, shall be free from faulty materials or workmanship for 180 days for OEM products, and 365 days for non-oem products from the date of shipment. This warranty period is inclusive of any statutory warranty. Any repair or replacement serviced product shall bear the same terms in this warranty. Siargo makes no other warranty, express or implied and assumes no liability for any special or incidental damage or charges, including but not limited to any damages or charges due to installation, dismantling, reinstallation or any other consequential or indirect damages of any kind. To the extent permitted by law, the exclusive remedy of the user or purchaser, and the limit of Siargo's liability for any and all losses, injuries or damages concerning the products including claims based on contract, negligence, tort, strictly liability or otherwise shall be the return of products to Siargo, and upon verification of Siargo to prove to be defective, at its sole option, to refund, repair or replacement of the products. No action, regardless of form, may be brought against Siargo more than 365 days after a cause of action has accrued. The products returned under warranty to Siargo shall be at user or purchaser's risk of loss, and will be returned, if at all, at Siargo's risk of loss. Purchasers or users are deemed to have accepted this limitation of warranty and liability, which contains the complete and exclusive limited warranty of Siargo, and it shall not be amended, modified or its terms waived except by Siargo's sole action. This warranty is subject to the following exclusions (1) Products that have been altered, modified or have been subject to unusual physical or electrical circumstances indicated but not limited to those stated in this document or any other actions which cannot be deemed as proper use of the products; (2) Siargo does not provide any warranty on finished goods manufactured by others. Only the original manufacturer's warranty applies; (3) Products re-sold to the third parties. www.siargo.com FS7002 (VC.4) 4/5

Contact Information Headquarters Siargo Ltd. 3100 De La Cruz Boulevard, Suite 210, Santa Clara, California 95054, USA Phone: +1-408-969-0368 Email: info@siargo.com Representative in US Servoflo Corporation 75 Allen Street, Lexington, MA 02421, USA Phone: +1-781-862-9572 Email: info@servoflo.com Representative in Japan Marubeni Information Systems Co., Ltd. Device Solutions Department 14th Floor, Shinjuku Garden Tower, 3-8-2, Okubo, Shinjuku-ku, Tokyo 169-0072, Japan Phone: +81-3-4243-4160 Fax: +81-3-4243-4198 Email: siargo@marubeni-sys.com Representative in Europe IDENTIC Stefanie Trojan In der Siedlerruh 24 69123 Heidelberg / Germany Phone: +49-(0)6221-7509777 Fax: +49-(0)6221-7509779 Email: info@identic.de This document is intended for distribution to customer(s) only. Siargo and its subsidiaries reserve the rights to change the specifications and/or descriptions without prior notice. www.siargo.com FS7002 (VC.4) 5/5