MXS-BRO SERIES SMALL MULTIPLE RECESSED This product must be installed in accordance with the applicable code by a person familiar with the construction and operation of the product and the hazards involved. Read all of these instructions before installing. Not rated for Insulated Ceilings (non IC rated). Disconnect power prior to servicing or installing. 1 2 3 4 Slide hanger bars into base plate in the desired direction. For wood joints bend end tabs 90 degrees. For added security install a nail or screw through the hole. Position base plate to desired location by sliding left/right or up/down. 5 6 7 8 To line up a row of fixtures, use centering holes on either side of base plate. When fixture is in its desired position, secure in place by tightening wing nuts. Unhinge lid of electrical box & connect input power to Primary of LED driver. Mark approximate fixture location in ceiling. Cut open using hole as your guide. MXS-Matrix-Small-BRO-Install Subject to change without notice REV 2016.04.11 1/12
2 MXS-BRO SERIES SMALL MULTIPLE RECESSED Cut out hole sizes MX 1 = 5 1/4 x 5 1/4 MX 2 MX 3 MX4(1x4) MX4(2x2) MX 6 = = = = = 5 1/4 x 10 1/4 5 1/4 x 15 1/4 5 1/4 x 20 1/8 10 1/8 x 10 1/8 5 1/4 x 29 7/8 9 10 11 12 Clip safety hook onto latch on side of trim. Connect wire connector(s) from trim to housing. Before installing trim, remove face ring, adapter & reflector by turning all parts counterclockwise. Compress trim clips flat to side of fixture, and then insert trim into ceiling cutout. With trim pushed into ceiling, push the end of each clip outwards until they lock in place. Glass Lens Option To Install an optional glass lens, twist counter-clockwise to release front ring, turn ring until tabs line up & ring drops out. Install glass lens into adaptor ring, (Glass Lens ordered separately) MXS-Matrix-Small-BRO-Install Subject to change without notice REV 2016.04.11 2/12
BRO 8010/9008 - S - ELV DIMMING INSTRUCTION 120VAC 60Hz INPUT ELECTRONIC LOW VOLTAGE DIMMER (ELV) LED DRIVER ELV DIMMING MXS-Matrix-Small-BRO-Install Subject to change without notice REV 2016.04.11 3/12
BRO 8010/9008 - P - 0-10V DIMMING INSTRUCTION 120VAC OR 277VAC, 50/60Hz INPUT 0-10V DIM+ (PURPLE) 0-10V DIMMING 0-10V DIM- (GREY/WHITE) MXS-Matrix-Small-BRO-Install Subject to change without notice REV 2016.04.11 4/12
BRO 8010/9008 - L - LUTRON DIMMING INSTRUCTION 120VAC OR 277VAC, 50/60Hz INPUT OPTIONAL LUTRON 3-WIRE DIMMING (YELLOW) LUTRON DIMMING OPTIONAL LUTRON ECOSYSTEM DIMMING LINES (PURPLE), WIRES NOT PROVIDED REFER TO DIMMING SYSTEM INSTRUCTION FOR WIRING MXS-Matrix-Small-BRO-Install Subject to change without notice REV 2016.04.11 5/12
BRO 8010/9008 - LE - LUTRON PHASE DIMMING INSTRUCTION 120VAC 60Hz INPUT LUTRON PHASE DIMMING MXS-Matrix-Small-BRO-Install Subject to change without notice REV 2016.04.11 6/12
BRO 8010/9008 - D - DALI DIMMING INSTRUCTION 120VAC OR 277VAC, 50/60Hz INPUT DALI DIMMING WIRES DALI DIMMING MXS-Matrix-Small-BRO-Install Subject to change without notice REV 2016.04.11 7/12
BRO 8018/9013 - S - ELV DIMMING INSTRUCTION 120VAC OR 277V, 50/60Hz INPUT ELECTRONIC LOW VOLTAGE DIMMER (ELV) @ 120V ONLY ELV DIMMING MXS-Matrix-Small-BRO-Install Subject to change without notice REV 2016.04.11 8/12
BRO 8018/9013 - P - 0-10V DIMMING INSTRUCTION 120VAC OR 277VAC, 50/60Hz INPUT 0-10V DIM+ (PURPLE) 0-10V DIMMING 0-10V DIM- (GREY/WHITE) MXS-Matrix-Small-BRO-Install Subject to change without notice REV 2016.04.11 9/12
BRO 8018/9013 - L - LUTRON DIMMING INSTRUCTION 120VAC OR 277VAC, 50/60Hz INPUT OPTIONAL LUTRON 3-WIRE DIMMING (YELLOW) LUTRON DIMMING OPTIONAL LUTRON ECOSYSTEM DIMMING LINES (PURPLE), WIRES NOT PROVIDED REFER TO DIMMING SYSTEM INSTRUCTION FOR WIRING MXS-Matrix-Small-BRO-Install Subject to change without notice REV 2016.04.11 10/12
BRO 8018/9013 - LE - LUTRON PHASE DIMMING INSTRUCTION 120VAC 60Hz INPUT LUTRON PHASE DIMMING MXS-Matrix-Small-BRO-Install Subject to change without notice REV 2016.04.11 11/12
BRO 8018/9013 - D - DALI DIMMING INSTRUCTION 120VAC OR 277VAC, 50/60Hz INPUT DALI DIMMING WIRES DALI DIMMING MXS-Matrix-Small-BRO-Install Subject to change without notice REV 2016.04.11 12/12