OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

Similar documents
O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

O2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)

ORB ORB. Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

ONRB ONRB. Narrow Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

DELI MODELS: PMNUM, PMFNUM, PMN2UM, PMFN2UM INSTALLATION & OPERATION HANDBOOK. Featuring. Technology P902077H. Rev 4 1/07 COMPONENT

DELI MODEL: OSA & OSAG INSTALLATION & OPERATION HANDBOOK P052392H. Rev /09 COMPONENT

RM with INNOVATOR Doors

HANDBOOK O3EIF MEAT CASES INSTALLATION & OPERATION

REAR LOAD DAIRY INSTALLATION & OPERATION HANDBOOK P056170D. Rev /10 COMPONENT

DELI MODELS: OSI, OWSI, OSIO & OWSIO INSTALLATION & OPERATION HANDBOOK. P052971K Rev. 8 7/04 COMPONENT

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

3-DECK ISLAND PRODUCE INSTALLATION & OPERATION HANDBOOK. P053096D Rev. 9 11/10 COMPONENT

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

OWIZ/OWIZV OWEZ/OWEZV

QLV5V-A - Glass Door Eliminator - Frozen Food. QIV5V-A - Glass Door Eliminator - Ice Cream. Applications: Specification Sheet 2 DR 3 DR 4 DR 5 DR

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

MULTI-DECK FROZEN FOOD MERCHANDISER INSTALLATION & OPERATIONS MANUAL. Table of Contents

RL with INNOVATOR II No Heat Doors

ORZ ORZH ONRZ. Table of Contents (ALSO INCLUDES ONRZH) Airflow & Defrost... 9 Fans & Case Cleaning Appendix... 11

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

ISLAND PRODUCE MODELS: OIP, OIPB, &OIPBB INSTALLATION & OPERATION HANDBOOK. P054956H Rev. 7 11/06 COMPONENT

RLT with INNOVATOR Doors

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

Engineering Plan Views

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

QDV5V - 1 Door Standard (Gemtron)

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

IMPORTANT KEEP IN STORE FOR FUTURE USE

RLNIE with INNOVATOR II

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

Case Study of Adding Glass Doors to Multi-Deck Meat Case

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

FG-L Technical Data Sheet

P/N _F NSF Certified June 2010

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

ORIZ ORIZH ONRIZ TABLE OF CONTENTS (ALSO INCLUDES ONRIZH) AIRFLOW & CASE TEMPERATURE... 9 FANS & CASE CLEANING APPENDIX...

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

Installation & Service Manual

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

PWEE Technical Data Sheet

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

Nosing Heater. Return Grill Heater

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

RMN with INNOVATOR Doors Technical Data Sheet

QC BEVERAGE/DAIRY/DELI

Low Flow Unit Coolers

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

Energy Efficient. Flexible Design Options.

INSTALLATION & OPERATION MANUAL QDV5V-A QDV5VT-A QIV5V-A, QIV5VT-A QLV5V-A, QLV5VT-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE

DAIRY/DELI PRODUCE C A S E S O5DMA INSTALLATION & OPERATION HANDBOOK. P056442G Rev /13

Unico Training. Class for R E Michel Salesmen

Installation & Service Manual

INSTALLATION & OPERATION MANUAL QDV6V-A QIV6V-A, QLV6V-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE. Part No. 31E11043 Date: 1/5/15

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

Installation & Service Manual

Installation & Service Manual

HVI-4-406R/HVI-4-408R

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

CDC-R & CDC-D BAKERY MULTI-DECK MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N UA L. Table of Contents

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

INSTALLATION & OPERATION MANUAL

MODEL RD-8 Self Contained MODEL RD-2

S2SGC MEAT/SEAFOOD MULTI-DECK MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N UA L. Table of Contents

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

Unico Training. Welcome to Unico!

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

NFW, NCW, NFWG, NCWG, NFWE, NCWE

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

Technical Manual Binair Monobloc Heat Pump

SERVICING SUPERMARKET REFRIGERATION EQUIPMENT By: Kenneth S. Franklin National Service Manager Hussmann Refrigeration, Inc.

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

QM5, QM5G Multi-Deck Meat Display Case. Part Number: 31E03028 Date: 08/13/2007

COMMERCIAL AIR HANDLER

INSTALLATION AND SERVICE MANUAL REMOTE TYPE DISPLAY CASE

Cabinet & Merchandiser Price List

Transcription:

GENERAL NOTES "---" indicates that the feature is not an option for this case model and/or the data is not available at this time. LED lights only. Maximum of 4 rows of Standard Output LED lighted shelves. SHIPPING WEIGHT Case --- Weight

ELECTRICAL DATA Case Fans Per High Efficiency Fans 20 Volt Length Case Amps Watts 4' 2 0.50 36.0 6' 3 0.75 54.0 8' 3 0.75 54.0 2' 4.00 72.0 LIGHTING DATA Case Length Lights per row Clearvoyant v4 LED Lighting (Per Light Row) Standard Power High Power (Cornice or Shelf) (Cornice Only) 20 Volts 20 Volts Amps Watts Amps Watts 4' 0.05 5.9 0.2 4.9 6' 2 0.08 9.4 0.20 23.8 8' 2 0.0.8 0.25 29.9 2' 3 0.5 7.6 0.37 44.8 GUIDELINES AND CONTROL SETTINGS BTUH/ft Superheat Set Point @ Bulb ( F) Evaporator ( F) Discharge Air ( F) Discharge Air Velocity (FPM) Front Sill height Conventional Parallel All Others 40 234 6-8 27 30 200 Standard 53 340 6-8 27 30 200 DEFROST CONTROLS Timed-Off Defrost Defrosts Per Day Fail-Safe (Min) Termination Temp (F) 6 40 47 NOTES "---" indicates the feature is not an option with this case model and/or that the data is not available at this time. Listed BTUH/ft data represent unlighted shelves. For LED lighting, add 9 BTUH/ft to determine Total Case Lighting BTUH Load, then BTUH load increases by 32 BTUH/ft when aftermarket merchandising accessories are utilized. Listed evaporator temperature represents unlighted shelves. For lighted shelves and/or aftermarket merchandising accessories, reduce the listed evaporator temperature by 2 F. Conventional Discharge Air Control Recommended Settings: Cut-In Temp = Discharge Air + 2 F; Cut- Out Temp = Discharge Air - 2 F. Listed discharge air velocity represents the average velocity immediately after defrost. Temperature and defrost settings listed above are recommended start-up settings. Final operational settings may need to be adjusted for the store conditions in which the case operates. The recommended evaporator temperatures may need to be adjusted based on system setup, store conditions, etc. The minimum recommended evaporator temperature is 4 F below the listed evaporator temperature.

SECOND NATURE DATA BTUH/ft (DR) Supply Discharge Conventiona GPM/ft Fluid Air Temp Case Model Coils Application Front Sill Type l Parallel (DR) Temp (F) (F) Meat All Others 40 234 0.36 20 30 Deli Standard 53 340 0.39 20 30 Meat All Others 40 234 0.85 25 30 Deli Standard 53 340 0.92 25 30 SECOND NATURE DATA Coils Application Front Sill Type Defrost Timed Off Defrost Fail Safe (Min) Termination Temp (F) Warm Fluid Defrost Fail Safe Termination (Min) Temp (F) Case Model Deli Standard 6 60 47 26 49 Meat All Others 6 45 47 26 49 Deli Standard 6 45 47 26 49

CORNICE OPTIONS CURVED CORNICE CURVED CORNICE FACETED CORNICE FACETED CORNICE WITH NIGHT COVER WITH NIGHT COVER FLAT CORNICE 34 7/8" 40 /4" 34 3/4" 38" 34" 36 5/8" FLAT CORNICE WITH WITH STANDARD NIGHT COVER EXTENDED FLAT FRONT 2 28 3/6" [7.5 cm] 22 5/6" [56.7 cm] 33 /6" [84.0 cm] 27" [68.6 cm] 33 7/6" [84.9 cm] 27 3/8" [69.5 cm] EXTENDED FRONT OPTIONS FLAT FRONT CLASSIC 2 METAL 2 3/6" [53.8 cm] 2 3/6" [53.7 cm] EXTENDED 30" [76.2 cm] 30" [76.2 cm] 33 /8" [84. cm] 27 /4" [69. cm] EXTENDED CLASSIC 2 POLYMER ORIGIN 2 2 3/6" [53.7 cm] 2 3/6" [53.8 cm] EXTENDED 30" [76.2 cm] 30" [76.2 cm] NOTES: Front sill height and overall case height varies with base frame height. Extended front sills are required on meat applications to maintain proper product temperature. An extended front has a minimum height of 24" on a 5" baseframe, or 30" on an " baseframe.

OPTIONAL WIRING TO THE TOP 2 in X 0 in X 4 in 34 7/8" [88.5 cm] 9" MIRROR OPTIONAL 9" MIRROR OPTIONAL 86 7/6" [29.6 cm] SHIPPING HEIGHT 84 3/6" [23.8 cm] OVERALL CASE HEIGHT 80 7/8" [205.4 cm] CASE HEIGHT 53 7/8" [36.8 cm] INTERIOR HEIGHT REAR PIPE BOX 6 in 8 in 32 /4" [8.9 cm] COIL PLENUM LOAD LIMIT 46 7/8" [9. cm] VISUAL DISPLAY 80 9/6" [204.6 cm] SHIPPING HEIGHT 78 5/6" [98.9 cm] OVERALL CASE HEIGHT 74 5/6" [88.8 cm] CASE HEIGHT REAR PIPE BOX 6 in 8 in 32 /4" [8.9 cm] COIL PLENUM LOAD LIMIT 3 3/4" [80.6 cm] 32 5/8" [82.8 cm] 43 /4" [09.9 cm] 5 /8" [3.0 cm] 6 5/8" [6.8 cm] 39 /4" [99.7 cm] 6 7/8" [42.9 cm] 2 /8" [53.7 cm] WIRING TO THE TOP (OPTIONAL) 2" MINIMUM AIR GAP PIPING TO TOP (OPTIONAL) 2" [30.4 cm] REAR REFRIGERATION LOCATED 8 3/4" ABOVE FINISH FLOOR 43 /4" [09.9 cm] 39 /4" [99.7 cm] 32 5/8" [82.9 cm] " [27.9 cm] 28 /2" [72.4 cm]* 5 3/6" [40.2 cm]** 34 5/6" [88.7 cm]** 3" [7.6 cm] 28 5/8" [72.7 cm] 22 3/4" [57.8 cm] 27" [68.6 cm] DEFAULT REFRIGERATION ELECTRICAL JUNCTION BOX /2" PVC DRAIN CONNECTION 48" [2.9 cm] 72" [82.9 cm] 96" [248.3 cm] 44" [365.8 cm] /2" [3.8 cm] {END} 8 3/4" [22.2 cm] NOTES: * : STUB-UP AREA ** : RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND DRAINS : AVAILABLE SHELF SIZES: 0", 2", 4", 6", 8", 20", 22" & 24" Ends add approximately " to case height, /2" to the back & " to the front. Back panels add approximately " to the rear of the case.