Digital EPIC 2 Safety manual

Similar documents
100 & 120 Series Pressure and Temperature Switches Safety Manual

SIL Safety Guide Series MS Single-Acting Spring-Return Hydraulic Linear Actuators

United Electric Controls One Series Safety Transmitter Safety Manual

Overfill Prevention Control Unit with Ground Verification & Vehicle Identification Options. TÜVRheinland

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

Mobrey Magnetic Level Switches

Failure Modes, Effects and Diagnostic Analysis

Rosemount Functional Safety Manual. Manual Supplement , Rev AF March 2015

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, Minnesota USA

STT850 and STT750 SmartLine Temperature Transmitter HART Communications Options Safety Manual 34-TT Revision 4 September 2017

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis. PR electronics A/S Rønde Denmark

PPA Michaël GROSSI - FSCE PR electronics

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

IEC61511 Standard Overview

Certification Report of the ST 3000 Pressure Transmitter with HART 6

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

Certification Report of the ST3000 Pressure Transmitter

Failure Modes, Effects and Diagnostic Analysis

Rosemount 2140:SIS Level Detector

Functional Safety: the Next Edition of IEC 61511

New Developments in the IEC61511 Edition 2

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd

SLG 700 SmartLine Level Transmitters Guided Wave Radar Safety Manual 34-SL Revision 4.0 December 2017

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

Assessment of the Safety Integrity of Electrical Protection Systems in the Petrochemical Industry

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, MN USA

Safety Integrity Verification and Validation of a High Integrity Pressure Protection System to IEC 61511

Safety Instrumented Systems

Failure Modes, Effects and Diagnostic Analysis

Soliphant M with electronic insert FEM52

Session Ten Achieving Compliance in Hardware Fault Tolerance

Addressing Challenges in HIPPS Design and Implementation

Safety in the process industry

FMEDA and Proven-in-use Assessment. Pepperl+Fuchs GmbH Mannheim Germany

Failure Modes, Effects and Diagnostic Analysis

High Integrity Pressure Protection System

Safety Transmitter / Logic Solver Hybrids. Standards Certification Education & Training Publishing Conferences & Exhibits

Introduction. Additional information. Additional instructions for IEC compliant devices. Measurement made easy

67 th Canadian Chemical Engineering Conference EDMONTON, AB OCTOBER 22-25, 2017

IEC Functional Safety Assessment

The SIL Concept in the process industry International standards IEC 61508/ 61511

Functional Safety Solutions

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd.

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

FMEDA Report. Failure Modes, Effects and Diagnostic Analysis. KFD0-CS-Ex*.54* and KFD0-CS-Ex*.56* Project: X7300

InstrumentationTools.com

Is your current safety system compliant to today's safety standard?

SIPART. Electropneumatic positioner Functional safety for SIPART PS2. Introduction. General safety instructions 2. Device-specific safety instructions

FUNCTIONAL SAFETY: A PRACTICAL APPROACH FOR END-USERS AND SYSTEM INTEGRATORS

Guidelines. Safety Integrity Level - SIL - Valves and valve actuators. February Valves

FUNCTIONAL SAFETY CERTIFICATE

Options for Developing a Compliant PLC-based BMS

Measurement of Safety Integrity of E/E/PES according to IEC61508

IEC Functional Safety Assessment

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

Technical Manual for the Manual Alarm Call Point BG

FUNCTIONAL SAFETY CERTIFICATE. BG Break Glass Unit

Technical Report Proven In Use SITRANS P500

Functional Safety Manual June pointek CLS500/LC500

FUNCTIONAL SAFETY OF ELECTRICAL INSTALLATIONS IN INDUSTRIAL PLANTS BY OTTO WALCH

Australian Standard. Functional safety Safety instrumented systems for the process industry sector

Pressure Transmitter cerabar M PMC 41/45 cerabar M PMP 41/45/46/48 with Output Signal ma/hart

Failure Modes, Effects and Diagnostic Analysis

ADIPEC 2013 Technical Conference Manuscript

Changes in IEC Ed 2

Safety Instrumented Systems Overview and Awareness. Workbook and Study Guide

Functional safety according to IEC / IEC Important user information. Major changes in IEC nd Edition

Functional Safety Manual Oil Leak Detector NAR300 System

INTERNATIONAL STANDARD

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

IEC PRODUCT APPROVALS VEERING OFF COURSE

The agri-motive safety performance integrity level Or how do you call it?

430128A. B-Series Flow Meter SIL Safety Manual

White Paper. Integrated Safety for a Single BMS Evaluation Based on Siemens Simatic PCS7 System

ACCURATE FAILURE METRICS FOR MECHANICAL INSTRUMENTS IN SAFETY APPLICATIONS

Proof Testing Level Instruments

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express

SAFETY INTEGRITY LEVEL MANUAL. IEC and IEC XP95 and Discovery SIL Approved Product Range

New requirements for IEC best practice compliance

FUNCTIONAL SAFETY MANUAL

Fire and gas safety systems:

Simply reliable: Process safety from Endress+Hauser

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

Topic MYTH FUNCTIONAL SAFETY IMPLIES HAVING A SIL RATED COMPONENT. Presented by : Arunkumar A

Integrated but separate

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Transcription:

Safety manual Before installation these instructions must be fully read and understood Table of contents Safety manual... 1 1. Introduction... 1 1.1 Terms and abbreviations... 2 1.2 Acronyms... 2 1.3 Product support... 3 1.4 Related literature... 3 1.5 Reference standards... 3 2. Device description... 3 3. Designing a sif using a manufacturer product... 3 3.1 Safety function... 3 3.2 Environmental limits... 3 3.3 Application limits... 3 3.4 Design verification... 3 3.5 SIL capability... 4 3.5.1 Systematic integrity... 4 3.5.2 Random integrity... 4 3.5.3 Safety parameters... 4 3.6 Connection of the D-EPIC to the SIS Logic-solver... 4 3.7 General requirements... 4 4. Installation and commissioning... 4 4.1 Installation... 4 4.2 Physical location and placement... 4 4.3 Proof test without automatic testing.. 4 4.4 Proof test with automatic partial valve stroke testing... 5 4.5 Repair and replacement... 5 4.6 Useful life... 5 4.7 Manufacturer notification... 5 Safety manual This document provides a for a. A provides information necessary to design, install, verify and maintain a Safety Instrumented Function (SIF) utilizing the Digital EPIC. 1 Introduction This safety manual provides information necessary to design, install, verify and maintain a Safety Instrumented Function (SIF) utilizing the D-EPIC2. This manual provides necessary requirements for meeting the IEC 61508 or IEC 61511 functional safety standards. Appendix A Start-up checklist 6 1. Start-up checklist... 6 www.westlockcontrols.com -EN 17/03 Page 1 of 7

1.1 Terms and abbreviations Safety Functional safety Basic safety Safety assessment Fail-safe state Fail safe Fail dangerous Fail dangerous undetected Fail dangerous detected Fail annunciation undetected Fail annunciation detected Fail no effect Low demand mode Freedom from unacceptable risk of harm. The ability of a system to carry out the actions necessary to achieve or to maintain a defined safe state for the equipment / machinery / plant / apparatus under control of the system. The equipment must be designed and manufactured such that it protects against risk of damage to persons by electrical shock and other hazards and against resulting fire and explosion. The protection must be effective under all conditions of the nominal operation and under single fault condition. An investigation to arrive at a judgment - based on evidence - of the safety achieved by safety-related systems. State where solenoid valve is de-energized and spring is extended. Failure that causes the valve to go to the defined fail-safe state without a demand from the process. Failure that does not respond to a demand from the process (i.e. being unable to go to the defined fail-safe state). Failure that is dangerous and that is not being diagnosed by automatic stroke testing. Failure that is dangerous but is detected by automatic stroke testing. Failure that does not cause a false trip or prevent the safety function but does cause loss of an automatic diagnostic and is not detected by another diagnostic. Failure that does not cause a false trip or prevent the safety function but does cause loss of an automatic diagnostic or false diagnostic indication. Failure of a component that is part of the safety function but that has no effect on the safety function. Mode where the frequency of demands for operation made on a safety-related system is no greater than half the proof test frequency. 1.2 Acronyms FMEDA HFT MOC PFDavg SFF SIF SIL SIS Failure modes, effects and diagnostic analysis. Hardware fault tolerance. Management of change. These are specific procedures often done when performing any work activities in compliance with government regulatory authorities. Average probability of failure on demand. Safe failure fraction, the fraction of the overall failure rate of a device that results in either a safe fault or a diagnosed unsafe fault. Safety instrumented function, a set of equipment intended to reduce the risk due to a specific hazard (a safety loop). Safety integrity level, discrete level (one out of a possible four) for specifying the safety integrity requirements of the safety functions to be allocated to the E/E/PE safety-related systems where Safety Integrity Level 4 has the highest level of safety integrity and safety integrity Level 1 has the lowest. Safety instrumented system - implementation of one or more safety instrumented functions. A SIS is composed of any combination of sensor(s), logic solver(s), and final element(s). Page 2 of 7

1.3 Product support Product support can be obtained from: Westlock Controls 280 Midland Ave. Saddle Brook, NJ 07663 USA 1.4 Related literature Hardware documents: D-EPIC2 Installation, Operation and Maintenance Instructions, Document Tech-491Q, Tech-511Q and QUICK START GUIDE VCIOM04592. Guidelines/references: Practical SIL Target Selection Risk Analysis per the IEC 61511 Safety Lifecycle, ISBN 978-1-934977-03-3, Exida Control System Safety Evaluation and Reliability, 3rd Edition, ISBN 978-1-934394-80-9, ISA Safety Instrumented Systems Verification, Practical Probabilistic Calculations, ISBN 1-55617-909-9, ISA 1.5 Reference standards Functional Safety IEC 61508: 2010 Functional safety of electrical/electronic/ programmable electronic safety-related systems. ANSI/ISA 84.00.01-2004 (IEC 61511 Mod.) Functional Safety Safety Instrumented Systems for the Process Industry Sector. 2 Device description The Digital EPIC Control Transmitter provides precision non-contact valve position feedback. Optional features include partial valve stroke testing. 3 Designing a sif using a manufacturer product 3.1 Safety function When used with a de-energize to trip final element subsystem, the D-EPIC2 will not interfere with the ability of the logic solver to bring the final element to its safe state. The D-EPIC2 is intended to be part of a final element subsystem as defined per IEC 61508 and the achieved SIL level of the designed function must be verified by the designer. 3.2 Environmental limits The designer of a SIF must check that the product is rated for use within the expected environmental limits. Refer to the Westlock Controls D-EPIC2 Brochure for environmental limits. 3.3 Application limits The materials of construction of a D-EPIC2 are specified in the Westlock Controls D-EPIC2 Brochure. It is especially important that the designer check for material compatibility considering on-site chemical contaminants. If the D-EPIC2 is used outside of the application limits or with incompatible materials, the reliability data provided becomes invalid. 3.4 Design verification A detailed Failure Mode, Effects, and Diagnostics Analysis (FMEDA) report is available from Westlock Controls. This report details all failure rates and failure modes as well as the expected lifetime. The achieved Safety Integrity Level (SIL) of an entire Safety Instrumented Function (SIF) design must be verified by the designer via a calculation of PFDAVG considering architecture, proof test interval, proof test effectiveness, any automatic diagnostics, average repair time and the specific failure rates of all products included in the SIF. Each subsystem must be checked to assure compliance with minimum hardware fault tolerance (HFT) requirements. The exida exsilentia tool is recommended for this purpose as it contains accurate models for the D-EPIC and its failure rates. The failure rate data listed the FMEDA report are only valid for the useful life time of a D-EPIC2. The failure rates will increase sometime after this time period. Reliability calculations based on the data listed in the FMEDA report for mission times beyond the lifetime may yield results that are too optimistic, i.e. the calculated Safety Integrity Level will not be achieved. Page 3 of 7

4 Installation and commissioning 3.5 Sil capability 3.5.1 Systematic integrity The product has met manufacturer design process requirements of Safety Integrity Level (SIL) 3. These are intended to achieve sufficient integrity against systematic errors of design by the manufacturer. A Safety Instrumented Function (SIF) designed with this product must not be used at a SIL level higher than stated without prior use justification by the end user or diverse technology redundancy in the design. 3.5.2 Random integrity When the final element assembly consists of many components (D-EPIC, actuator, solenoid, quick exhaust valve, etc.) the SIL must be verified for the entire assembly using failure rates from all components. This analysis must account for any hardware fault tolerance and architecture constraints. 3.5.3 Safety parameters For detailed failure rate information refer to the Failure Modes, Effects and Diagnostic Analysis Report for the D-EPIC2. 3.6 Connection of the D-EPIC to the SIS logicsolver The D-EPIC is connected to the safety rated logic solver which is actively performing the safety function as well as automatic diagnostics designed to diagnose potentially dangerous failures within the D-EPIC2, (i.e. partial valve stroke test). 3.7 General requirements The system s response time shall be less than the process safety time. All SIS components including the D-EPIC2 must be operational before process start-up. User shall verify that the D-EPIC2 is suitable for use in safety applications by confirming the D-EPIC2 s nameplate is properly marked. Personnel performing maintenance and testing on the D-EPIC2 shall be competent to do so. Results from the proof tests shall be recorded and reviewed periodically. The useful life of the D-EPIC2 is listed in Section 5.4 and discussed in the Failure Modes, Effects and Diagnostic Analysis Report for the D-EPIC2. 4.1 Installation The D-EPIC2 must be installed per standard practices outlined in the Installation Manual. The environment must be checked to verify that environmental conditions do not exceed the ratings. The D-EPIC2 must be accessible for physical inspection. 4.2 Physical location and placement The D-EPIC shall be accessible with sufficient room for connections and shall allow manual proof testing. Pneumatic piping to the final element subsystem shall be kept as short and straight as possible to minimize the airflow restrictions and potential clogging. Long or kinked pneumatic tubes may also increase the valve closure time. The D-EPIC shall be mounted in a low vibration environment. If excessive vibration can be expected special precautions shall be taken to ensure the integrity of pneumatic connectors or the vibration should be reduced using appropriate damping mounts. 4.3 Proof test without automatic testing The objective of proof testing is to detect failures within a Westlock Controls D-EPIC2 that are not detected by any automatic diagnostics of the system. Of main concern are undetected failures that prevent the safety instrumented function from performing its intended function. The frequency of proof testing, or proof test interval, is to be determined in reliability calculations for the safety instrumented functions for which a Westlock Controls D-EPIC2 is applied. The proof tests must be performed at least as frequently as specified in the calculation in order to maintain the required safety integrity of the safety instrumented function. Page 4 of 7

The following proof test is recommended. The results of the proof test should be recorded and any failures that are detected and that compromise functional safety should be reported to Westlock Controls. The suggested proof test consists of ensuring the electrical isolation between the D-EPIC2 and the solenoid circuit, see Table 1. Table 1 - Suggested proof test Step Action 1 Bypass the safety function and take appropriate action to avoid a false trip. 2 Use digital communications to retrieve any diagnostics and take appropriate action. 3 Disconnect the logic solver and solenoid from their terminal blocks on the D-EPIC2. 4 Ensure that there is no electrical continuity between the 4-20 ma terminals and the logic solver and solenoid terminals 5 Reconnect the logic solver and solenoid to their terminal blocks on the D-EPIC2. 6 Remove the bypass and otherwise restore normal operation. This test will detect >99% of possible DU failures in the D-EPIC2. The person(s) performing the proof test of a D-EPIC should be trained in SIS operations, including bypass procedures, valve maintenance and company Management of Change procedures. No special tools are required. 4.4 Proof test with automatic partial valve stroke testing An automatic partial valve stroke testing scheme that performs a full stroke of the isolation valves in the D-EPIC2 and measures valve movement timing will detect most potentially dangerous failure modes. It is recommended that a physical and electrical inspection (Table 1) be performed on a periodic basis with the time interval determined by plant conditions. A maximum inspection interval of five years is recommended. 4.5 Repair and replacement Repair procedures in the D-EPIC2 Installation, Operation and Maintenance manual must be followed. 4.6 Useful life The useful life of the D-EPIC2 is 50 years. 4.7 Manufacturer notification Any failures that are detected and that compromise functional safety should be reported to Westlock Controls. Please contact Westlock Controls customer service. Page 5 of 7

Appendix A Start-up checklist This appendix provides a Start-up Checklist for a PRODUCT. A Start-up Checklist will provide guidance during PRODUCT deployment. 1 Start-up checklist The following checklist may be used as a guide to employ the D-EPIC in a safety critical SIF compliant to IEC61508/IEC 61511. # Activity Result Design Target Safety Integrity Level and PFDavg determined Correct valve mode chosen (Fail-closed, Fail-open) Design decision documented Pneumatic compatibility and suitability verified SIS logic solver requirements for valve tests defined and documented Routing of pneumatic connections determined SIS logic solver requirements for partial stroke tests defined and documented Design formally reviewed and suitability formally assessed Implementation Physical location appropriate Pneumatic connections appropriate and according to applicable codes SIS logic solver valve actuation test implemented Maintenance instructions for proof test released Verification and test plan released Implementation formally reviewed and suitability formally assessed Verified By Date # Activity Result Verification and testing Electrical connections verified and tested Pneumatic connection verified and tested SIS logic solver valve actuation test verified Safety loop function verified Safety loop timing measured Bypass function tested Verification and test results formally reviewed and suitability formally assessed Maintenance Tubing blockage / partial blockage tested Safety loop function tested Maintenance Tubing blockage / partial blockage tested Safety loop function tested Verified By Date Page 6 of 7

Engineering document reference This safety manual is based on the latest engineering update, and forms part of the certification for the DEPIC-2 series. To ensure you have the most recent version of this document, please check the document library on our website (westlockcontrols.com). Translations Where translated the copy is taken from the original English document -EN as checked by the relevant certification body and therefore the original English document will prevail. No rights or liability can be derived from any translation. Previous documents VCIOM-04978 replaces all previous safety manuals for the DEPIC-2 series including SMAN-004. www.westlockcontrols.com Westlock. We reserve the right to change designs and specifications without notice. Page 7 of 7