Environmental Chambers

Similar documents
Environmental Chambers

& Freezers. Selection Guide. Laboratory Refrigerators & Freezers. Accessories & Options

OVENS Forced Convection Ovens. Economy Forced Convection Ovens. Vacuum Ovens.

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Compact design for personal use Ready to network with your computer.

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities.

Refrigerated Incubators / Environmental Testing Chambers

Faster Temperature (& Humidity) Chamber

Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test

Environmental Stress Chamber AR series

Constant climate chamber with ICH-compliant illumination

Digital incubating/ refrigerating benchtop shakers

Ovens. General Applications. Forced Convection Ovens. Natural Convection Ovens. Vacuum Ovens. Clean Ovens, Class 100

Bench-Top Type Temperature (& Humidity) Chamber

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

Thermal Shock Chamber TSE 11

STABILITY ICH. ICH Stability Tests

Constant climate chambers

FITOCLIMA 600 & 1200 PHARMA

Constant climate chambers

FITOCLIMA 600 & 1200 STABILITY

FITOCLIMA 600 & 1200 STABILITY

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6

Fitoclima Pharma. Stability and Photostability Chambers for the pharmaceutical industry

Constant climate chambers

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6

Utility. High performance by special glass. Supports high-temperature, high-humidity testing

Constant climate chambers

External and internal circulation with powerful pumping capability

Recirculating Coolers

Plant growth chambers

VWR symphony CO 2 INCUBATORS

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer

Faster Temperature (& Humidity) Chamber

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Constant climate chamber with humidity

Heated and Refrigerated Incubators

Constant climate chambers

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Constant climate chambers

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Compact Ultra Low Temperature Chamber

HOT AIR OVEN. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

PHOTOSTABILITY CHAMBERS

Constant climate chambers

Stability & Shelf Life

New Generation KBF 240 series

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

Smart Oven (SWOF / SWON model) Oven (WOF / WON model) Precise Vacuum Oven (WOV model)

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

KMF Environmental test chamber for constant climate

Liquid to Liquid Thermal Shock Chamber TSB 21 TSB 51

Benchtop CO 2 Incubator. the Oasis 6400 series

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Customized Industrial Products

Thermo Scientific Precision Ovens

TEMPERATURE AND HUMIDITY TEST CHAMBER LTHC-A1 SERIES

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Thermo Scientific Heratherm Heating and Drying Ovens. efficient

MOV Series Electric Ovens Dry Heat Sterilizers MOV-112F/212F MOV-112/212 MOV-112S/212S MOV-112F MOV-212

FITOCLIMA 600 & 1200 BIO

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Environmental simulation chamber for complex alternating climate profiles

STABILITY TEST CHAMBERS

Ovens. DAIHAN Scientific

Thermal Shock Chambers TSA Series

Photo Stability Chamber

ICH750L. Climate Chamber. Product specification

TCR. Features: TISSUE CULTURE

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

DOUBLE DOOR FREEZER.

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

BATHS SHAKERS STIRRERS HOTPLATES INCUBATORS HEATING MANTLES INCUBATORS

Operation Manual. (Version 1.5.1)

Plant Growth Humidity Chamber

Stability Chambers & Rooms

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Thermo Scientific Forma Environmental Chambers. Controlled Temperature Storage Solutions


Sterilizer. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Sterilizer Overview. Page

ENVAIR lab CO2 Incubator

Ultra-Low Temperature Chest Freezers

NEW! Thermo Scientific Revco PLUS -86 C Freezers. Protecting Your Life s Work

Cell Culture CO2 Incubators

Thermo Scientific Forma Environmental Chambers. Controlled Temperature Storage Solutions. Optimum uniformity. plus a wide temperature range

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32

ICH260C. Climate Chamber. Product specification

Benchtop Test Chambers Temperature and Humidity

TCC-34. Features: TISSUE CULTURE

Advantages / Characteristics

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

Pioneer in HAST Technology HIRAYAMA MANUFACTURING CORPORATION

Transcription:

Temperature & Chambers. Temperature & Chambers - Tabletop type. Fingerprint Development Chamber - Tabletop type. Temperature Chambers. Temperature Chambers - Tabletop type. Clean Temperature & Chambers. Plant Growth Chambers. Selection Guide Temperature (& ) Chambers Description Operating Temp. Range 1) ( / ) Operating Humid. Full Range 2) (%RH) Chamber Volume (L / cu ft) Page Temperature & Chamber (Floor type) Temperature & Chamber (Tabletop type) Temperature Chamber (Floor type) Temperature Chamber (Tabletop type) Clean Temperature & Chamber (Floor type) TH-G Series 25 to 98 180 to 1000 / 6.4 to 35.3-35 to 150 / -31 to 302 TH-I Series 20 to 98 180 to 408 / 6.4 to 14.4 TH-GU-300-60 to 150 / -76 to 302 25 to 98 300 / 10.6 94-107 TH-TG Series -5 to 100 10 to 95 190 to 960 / 6.7 to 33.9 TH-ICH 3) Series -5 to 85 20 to 85 300, 760 / 10.6, 26.8 TH-ME Series -20 to 150 / -4 to 248 30 to 95 108-25 to 100 /0.9 to 3.53 TH-PE Series 0 to 100 / 32 to 212 35 to 95 113 TH-PF-100 4) 40 to 100 / 104 to 212 50 to 90 100 / 3.53 115 TC-G Series -35 to 150 / -31 to 302-180 to 1000 / 6.4 to 35.3 101 TC-GU-300-60 to 150 / -76 to 302-300 / 10.6 102 TC-ME Series -20 to 120 / -4 to 248-25 to 100 / 0.9 to 3.53 114 TH-CR-270-35 to 100 / -31 to 212 30 to 90 270 / 9.5 118-121 1) Operating Temperature Rang is without. 2) Please, refer to detail specification in catalog. 3) TH-ICH Series Temperature Rang is without Light and. 4) Fingerprint development chamber. Plant Growth Chambers Description Operating Temp. Range 1) ( / ) Operating Humid. Full Range (%RH) Chamber Volume (L / cu ft) Page Plant Growth Chambers (Floor type) GC-300TL 5 to 50 / 41 to 122 GC-300TLH - Lamp off 10 to 50 / 50 to 122 GC-1000TL - Lamp on - 300 / 10.6 50 to 90 300 / 10.6 1000 / 35.3 124-126 Accessories & Options Description Page for Temperature & Chambers 122-123 for Plant Growth Chambers 127

General Applications Temperature (& ) Chambers Test for reliability, durability, climatic, freezing resistance, quality assurance, thermal endurance etc. - Testing for electric and electronic component, sensors. - Testing for semiconductor, PCB, LCD & LED. - Pharmaceutical tests. - Mechanical / Military / Aircraft engineering. - Automobile, Transport / automobile supply industries. - Chemical / Petrochemical industries. - Construction materials / Plastic / Textile industries. - Testing mould, liquor, cigar, paintings. - Testing metal related industries like plating etc. - Ninhydrin, DFO and other fingerprint development processes. (Only TH-PF-100) Plant Growth Chamber - Agriculture experiment with growth of plants. - Growth experiment of animals and insects. - Food preservation experiments. - Genetic of life science researches. - Genetic researches and pathology of plants. - Retardation researches of seeds. - Tissue culture of plants and germinating researches of seeds. Technical Benefits Safety functions 1) Self-protecting cut-off function: - over temperature, leakage electric or overvoltage automated cut the power supply for operating, heating element and controller orderly before the unit shuts down. 2) Time setting function for automated run / off: - Enable to be started or shut down automatically at a preset time. - A timer operation can be set for month, data, day of the week and time. 3) Low fluid level protection, water leakage alarm: - Intermittent tone rings and optical signal alarm. - Water supply circuit compartment is completely separate from the others for safe operation. 4) Door-open warning alarm: - Intermittent tone rings and optical signal alarm displays. - Heating element, fan and platform automatically stop when door opening to minimize heat loss and protect operator. Optimum control performance 1) Microprocess PID control / Auto-tuning / Calibration. 2) Optimize CPU logic control system. - Optimum control for temperature / humidity with economical control in power consumption. 3) Touch screen type monitor. - 5.7-inch Color LCD with interactive input system using touch keys. (Floor Type) - Temperature & humidity / timer settings and operating condition. - Temperature, humidity, other operating parameters, and a record of previous operation are also displayed in graph form. - Easily recognizable set values; set point (SP) / proportional value (PV) are also added on the color LED controller. Protect the global environment - HFC refrigerant causes no damage to ozone layer. - Complies with the measures for ozone layer protection specified by the Montreal Protocol.

Temperature (& ) Chambers 94 ON-G series is used for all sterilization and drying tasks that do not require high drying Certification only for the TH-G-180 300 408 rates or special time requirements, ideal for drying applications requiring a gentle airflow. Floor type TH-G / TH-I / TC-G series

Temperature (& ) Chambers Dimensions (TH-G/ TH-I/ TC-G series) 95 Models Capacity W D H A B TH-G 180L (6.4cu ft) 1025mm (40.4 ) 1035mm (40.7 ) 1530mm (60.2 ) 450mm (17.7 ) 1230mm (48.4 ) TH-I 300L (10.6cu ft) 1120mm (44.1 ) 1070mm (42.1 ) 1730mm (68.1 ) 450mm (17.7 ) 1230mm (48.4 ) TC-G 408L (14.4cu ft) 1120mm (44.1 ) 1240mm (48.8 ) 1730mm (68.1 ) 520mm (20.5 ) 1230mm (48.4 ) TH-G TC-G 800L (28.3cu ft) 15700mm (61.8 ) 1245mm (48.8 ) 2060mm (81.1 ) 490mm (19.3 ) 1260mm (49.6 ) 1000L (35.3cu ft) 15700mm (61.8 ) 1445mm (56.9 ) 2060mm (81.1 ) 560mm (22.0 ) 1260mm (49.6 ) Temperature & control range (TH series only) Relative % RH 98%RH 95%RH TH-G type (180, 300, 408L) TH-GU-300 40 ~ 85% RH at 15 25 ~ 98% RH at 25 ~ 80 25 ~ 80% RH at 90 TH-G type (800, 1000L) 50 ~ 90% RH at 20 45 ~ 95% RH at 25 40 ~ 95% RH at 30 ~ 90 Temperature TH-I type (180, 300, 408L) 30 ~ 80% RH at 10 20 ~ 98% RH at 25 ~ 80 20 ~ 80% RH at 90

Temperature (& ) Chambers Operating & Constructional features 96 Door Catch & Trim Color LCD Controller User-friendly design Standard environmental test chambers. High quality 304 stainless steel exterior and interior. Casters for easy transport and installation. Convenient maintenance - available to check total operating time. Enough chamber capacity up to maximum 1000L. Select your optimum chamber from a full variation. - The series provide three variations in temperature (& humidity) range of -35 to 150, -35 to 120, -60 to 150 / upmost 20 to 98% RH, and five capacities of 180L, 300L, 408L, 800L, and 1000L, with a total 15 models altogether. Exclusive door lock & trim. - Vice lock type door catch and foamed silicone packing ensure perfect chamber seal. - Door open warning alarm. Inner door. - Optional inner glass door has four holes to handle inside specimen without opening the door. (Except for 800L and 1000L) Ventilation. - Ventilation vent is located at the upper right side of the unit. Recorder. (optional) - 6-point dots type recorder with digital display. Cartridge type tank for easy water supply. - Maintenance can be done easily from the front side. - A center window allow to check the amount of water remaining easily. Viewing window for observation. - A tempered window provides a clear view of your specimen during testing. - Improved lighting provided. Cable port for running in wires. - Basic hole of 50mm diameter cable port is standard equipped on left side of chambers for wiring to the specimen. We also provide additional 50 or 80mm diameter cable port. (Optional) Easy cleaning of condenser air-filter. - To prevent deterioration of refrigerator, keep filtering dust by periodical filter cleaning. Digital Recorder (optional) Safety functions Leakage breaker for power supply. Over current protector. Overheat / overcool protectors. Switch-off after alarm for over heating. Water empty. (TH-G / TH-GU / TH-I only) Door opening alarm. Vice lock door closing equipment.

Temperature (& ) Chambers Control operation Microprocess PID control / Auto-tuning / Calibration. Languages support in three kinds of English, Chinese, and Korean. Optimize CPU logic control system. - Optimum control for temperature / humidity with economical control in power consumption. Touch screen type monitor. - 5.7 inch Color LCD with interactive input system using touch keys. - Temperature & humidity / timer settings and operating condition. - Temperature, humidity, other operating parameters, and a record of previous operation are also displayed in graph form. - Easily recognizable set values; set point (SP) / proportional value (PV) are also added on the color LED controller. Programming operation. Description TH-G, I, GU / TC-G, GU series Programmable pattern capacity 120 Pattern repeat time 999 Max. segments per a pattern 100 Available max. segments* 1200 Programmable process time per a segment 0 to 99 hr 59 min * Even though the max. segments per a pattern are 100, available total segments are up to 1200 not 12000, so you need to arrange the number of segment an patterns properly. Water Tank 97 Computer interface. (optional) - Available to save all data in Excel. - Provide a software. - The program information, setting values backup / recovery, and temperature / humidity values storage. By using RS-485 communication port offer maximum 9 sets of Temperature & chamber can be connected by one PC. (optional) Air filter Multi-control Display Single-control Display Program setting Display Graph Display Ventilation

Temperature & Chambers Specifications & Ordering Informations 98 Chamber volume (L / cu ft) 180 / 6.4 300 / 10.6 408 / 14.4 800 / 28.3 1000 / 35.3 Control system Controller Temperature Time Refrigeration Cooler Heater Sensor Range ( / ) Fluctuation 1) ( / ) at 55 / 60%RH Variation 1) ( / ) at 55 / 60%RH Heating - without humidity (Min.) Cooling - without humidity (Min.) Range (%RH) Fluctuation 1) ( %RH) at 60%RH / 55 Variation 1) ( %RH) at 60%RH / 55 System BDBC2 system - Balanced Dehumidifying & Bath Cooling control Programmable, Touch screen type controller (5.7 Color monitor) -35 to 150 / -31 to 302 without humidity *best programmable control range : -30 to 140 / -22 to 284 0.1 / 0.18 0.2 / 0.36 0.2 / 0.36 0.3 / 0.55 0.3 / 0.55 0.6 / 1.08 0.5 / 0.9 0.5 / 0.9 0.5 / 0.9 0.5 / 0.9 50 From -35 to 120 (-31 to 248 ) 60 From -35 to 120 (-31 to 248 ) 60 From 20 to -35 (68 to -31 ) on singe point control * 40 to 85 at 15 (59 ) 50 to 90 at 20 (68 ) 25 to 98 at 25 to 80 (77 to 176 ) 45 to 95 at 25 (77 ) 25 to 80 at 90 (194 ) 40 to 95 at 30 to 90 (86 to 194 ) 0.3 0.4 0.3 0.5 0.6 Mechanical single stage refrigerator system (air-cooled condenser) 3.0 Mechanical dual stage refrigerator system (air-cooled condenser) Refrigerant R-404A R-404A (1st step), R-23 (2nd step) Capacity (W) 1500 4250 Plate fin cooler Ni-Cr Wire Heater / SUS sheath Heater Drying bulb (W) 2000 3000 bulb (W) 1500 2000 Temperature Pt 100 Electronic sensor - Free of drying a wet pack and good reaction time Interior Stainless steel #304 Exterior Stainless steel #304 Insulation Polyurethane foam 100mm (3.94 ) Door Glass wool Air flow Tangent blower (90W) 4 sets of sirocco fan (4 90W) Water supply Dimensions (W D H) Model TH-G-180 TH-G-300 TH-G-408 TH-G-800 TH-G-1000 Capacity 15L (0.53cu ft) - Cartridge type Direct water supplying system Water quality Interior (mm / inch) Exterior (mm / inch) Viewing windows (mm / inch) 500 630 600 / 19.7 24.8 23.6 1025 1035 1530/ 40.4 40.7 60.2 ph6.2 to 7.2 / Electrical conductivity 20 /cm to below 600 630 800 / 23.6 24.8 31.5 1120 1070 1730 / 44.1 42.1 68.1 200 330 / 7.9 13.0 600 850 800 / 23.6 33.5 31.5 1120 1240 1730 / 44.1 44.8 68.1 1000 800 1000 / 39.4 31.5 39.4 1570 1245 2060 / 61.8 49.0 81.1 1000 1000 1000 / 39.4 39.4 39.4 270 330 / 10.6 13.0 1570 1445 2060 / 61.8 56.9 81.1 Net weight (kg / lbs) 310 10 / 683.4 22.0 375 10 / 826.7 22.0 400 10 / 881.8 22.0 610 10 / 1345 22.0 670 10 / 1477 22.0 Cable Port Interface Basically one hole provided / 50mm (2.0 ) Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional] Electrical Requirements (230V) 60Hz / 1ph / 23.0A - Cat. No. AAH80011 AAH80021 AAH80031 - - Electrical Requirements (230V) 50Hz / 1ph / 23A 50Hz / 3ph / 22.5A Cat. No. AAH80012 AAH80022 AAH80032 AAH80042 AAH80052 Electrical Requirements (380V) 50Hz / 3ph / 7.7A 50Hz / 3ph / 13.0A Cat. No. AAH80018 AAH80028 AAH80038 AAH80048 AAH80058 1) Technical data. (according to DIN 12880, IEC 60068) Certification only for the TH-G-180 300 408 Permissible ambient Condition: Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85%. All specifications are under ambient temperature 20 (68 ), no load.

Temperature & Chambers Specifications & Ordering Informations Model TH-I-180 TH-I-300 TH-I-408 Chamber volume (L / cu ft) 180 / 6.4 300 / 10.6 408 / 14.4 Control system Controller Temperature Time Refrigeration Cooler Heater Sensor Air flow Water supply Dimensions (W D H) Cable Port Interface Range ( / ) Fluctuation 1) ( / ) at 55 / 60%RH Variation 1) ( / ) at 55 / 60% Heating - without humidity (Min.) BDBC2 system - Balanced Dehumidifying & Bath Cooling control Programmable, Touch screen type controller (5.7 Color monitor) -35 to 150 / -31 to 302 without humidity *best programmable control range : -30 to 140 / -22 to 284 0.1 / 0.18 0.2 / 0.36 0.2 / 0.36 0.6 / 1.08 0.5 / 0.9 0.5 / 0.9 50 From -35 to 120 (-31 to 248 ) Cooling - without humidity (Min.) 60 From 20 to -35 (68 to -31 ) on singe point control * Range (%RH) Fluctuation 1) ( %RH) at 60%RH / 55 Variation 1) ( %RH) at 60%RH / 55 System Refrigerant 30 to 80 at 10 (50 ) 20 to 98 at 25 to 80 (77 to 176 ) 20 to 80 at 90 (194 ) 0.3 0.4 0.3 3 3 3 Mechanical single stage refrigerator system (air-cooled condenser) R-404A Capacity (W) 1500 Plate fin cooler Ni-Cr Wire Heater / SUS sheath Heater Drying bulb (W) 2000 bulb (W) 1500 Temperature Pt 100 Electronic sensor - Free of drying a wet pack and good reaction time Interior Stainless steel #304 Exterior Stainless steel #304 Insulation Door Capacity Water quality Interior (mm / inch) Exterior (mm / inch) Viewing windows (mm / inch) 500 630 600 / 19.7 24.8 23.6 1025 1035 1530 / 40.4 40.7 60.2 Polyurethane foam 100mm (3.94 ) Glass wool Tangent blower (90W) 15L (0.53cu ft) - Cartridge type ph6.2 to 7.2 / Electrical conductivity 20 / cm to below 600 630 800 / 23.6 24.8 31.5 1120 1070 1730 / 44.1 42.1 68.1 200 330/7.9 13.0 600 850 800 / 23.6 33.5 31.5 1120 1240 1730 / 44.1 44.8 68.1 Net weight (kg / lbs) 310 10 / 683.4 22.0 375 10 / 826.7 22.0 400 10 / 881.8 22.0 Basically one hole provided / 50mm (2.0 ) Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional] Electrical Requirements (230V) 60Hz / 1ph / 23.0A Cat. No. AAH80111 AAH80121 AAH80131 Electrical Requirements (230V) 50Hz / 1ph / 23.0A Cat. No. AAH80112 AAH80122 AAH80132 Electrical Requirements (380V) 50Hz / 3ph / 7.7A Cat. No. AAH80118 AAH80128 AAH80138 99 1) Technical data. (according to DIN 12880, IEC 60068) Permissible ambient Condition : Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85% All specifications are under ambient temperature 20 (68 ), no load.

Temperature & Chambers Specifications & Ordering Informations 100 Model TH-GU-300 Chamber volume (L / cu ft) 300 / 10.6 Control system Controller Temperature Time Refrigeration Cooler Heater Sensor Air flow Water supply Dimensions (W D H) Cable Port Range ( / ) Fluctuation 1) ( / ) at 40 / 60%RH Variation 1) ( / ) at 40 / 60%RH Heating - without humidity (Min.) Cooling - without humidity (Min.) Range (%RH) BDBC2 system - Balanced Dehumidifying & Bath Cooling control Programmable, Touch screen type controller (5.7 Color monitor) -60 to 150 / -76 to 302 without humidity *best programmable control range : -50 to 140 / -58 to 284 0.3 / 0.54 0.5 / 0.9 60 From -60 to 120 (-76 to 248 ) 65 From 20 to -60 (68 to -76 ) on singe point control 40 to 85 at 15 (59 ) 25 to 98 at 25 to 80 (77 to 176 ) 25 to 80 at 90 (194 ) Fluctuation 1) ( %RH) 3 Variation 1) ( %RH) 3 System Mechanical single stage refrigerator system (air-cooled condenser) Refrigerant R-404A / R-23 Capacity (W) 3000 Plate fin cooler Ni-Cr Wire Heater / SUS sheath Heater Drying bulb (W) 2000 bulb (W) 1500 Temperature Pt 100 Electronic sensor - Free of drying a wet pack and good reaction time Interior Stainless steel #304 Exterior Stainless steel #304 Insulation Door Capacity Water quality Interior (mm / inch) Exterior (mm / inch) Viewing windows (mm / inch) Net weight (kg / lbs) Polyurethane foam 100mm (3.94 ) Glass wool Tangent blower (90W) 15L (0.53cu ft) - Cartridge type ph6.2 to 7.2/ Electrical conductivity 20 / cm to below 600 630 800 / 23.6 24.8 31.5 1120 1070 1730 / 44.1 42.1 68.1 200 330 / 7.9 13.0 395 10 / 870.8 22.0 Basically one hole provided / 50mm (2.0 ) Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Electrical Requirements (230V) 60Hz / 1ph / 29.0A Cat. No. AAH80321 Electrical Requirements (230V) 50Hz / 1ph / 29.0A Cat. No. AAH80322 Electrical Requirements (380V) 60, 50Hz / 3ph / 9.7A Cat. No. AAH80328 1) Technical data. (according to DIN 12880, IEC 60068) Permissible ambient Condition: Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85%. Upon request, other sizes of chambers are available. Please contact with us. All specifications are under ambient temperature 20 (68 ), no load.

Temperature Chambers Specifications & Ordering Informations Model TC-G-180 TC-G-300 TC-G-408 TC-G-800 TC-G-1000 Chamber volume (L / cu ft) 180 / 6.4 300 / 10.6 408 / 14.4 800 / 28.3 1000 / 35.3 Control system Controller Temperature Time Cooling fuzzy control system Programmable, Touch screen type controller (5.7 Color monitor) Range ( / ) -35 to 150 / -31 to 302 Fluctuation 1) ( / ) at 100 Variation 1) ( / ) at 100 Heating - without humidity (Min.) Cooling - without humidity (Min.) 0.2 / 0.36 0.1 / 0.18 0.9 / 1.62 1.0 / 1.80 0.8 / 1.44 0.4 / 0.72 0.5 / 0.9 50 From -35 to 120 (-31 to 248 ) 60 From 20 to -35 (68 to -31 ) on singe point control Mechanical single stage refrigerator system (air-cooled condenser) 60 From -35 to 120 (-31 to 248 ) Mechanical dual stage refrigerator system (air-cooled condenser) System Refrigeration Refrigerant R-404A R-404A (1st step), R-23 (2nd step) Capacity (W) 1500 4250 Cooler Plate fin cooler Heater Ni-Cr Wire Heater Drying bulb (W) 2000 3000 Sensor Temperature Pt 100 Interior Stainless steel #304 Exterior Stainless steel #304 Insulation Polyurethane foam 100mm (3.94 ) Door Glass wool Air flow Tangent blower (90W) 4 sets of sirocco fan (4 90W) Interior (mm / inch) 500 630 600 / 19.7 24.8 23.6 600 630 800 / 23.6 24.8 31.5 600 850 800 / 23.6 33.5 31.5 1000 800 1000 / 39.4 31.5 39.4 1000 1000 1000 / 39.4 39.4 39.4 101 Dimensions (W D H) Exterior (mm / inch) 1025 1035 1530 / 40.4 40.7 60.2 1120 1070 1730 / 44.1 42.1 68.1 1120 1240 1730 / 44.1 44.8 68.1 1570 1245 2060 / 61.8 49.0 81.1 Viewing windows (mm / inch) 200 330 / 7.9 13.0 270 330 / 10.6 13.0 Net weight (kg / lbs) 310 10 / 683.4 22.0 375 10 / 826.7 22.0 400 10 / 881.8 22.0 610 10 / 1345 22.0 1570 1445 2060 / 61.8 56.9 81.1 670 10 / 1477 22.0 Cable Port Interface Basically one hole provided / 50mm (2.0 ) Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional] Electrical Requirements (230V) 60Hz / 1ph / 16.2A - Cat. No. AAH81411 AAH81421 AAH81431 - - Electrical Requirements (230V) 50Hz / 1ph / 16.2A 50Hz / 3ph / 22.5A Cat. No. AAH81412 AAH81422 AAH81432 AAH81442 AAH81452 Electrical Requirements (380V) 50Hz / 3ph / 5.2A 50Hz / 3ph / 11.5A Cat. No. AAH81418 AAH81428 AAH81438 AAH81448 AAH81458 1) Technical data. (according to DIN 12880, IEC 60068) Certification only for the TC-G-180 300 408. Permissible ambient Condition: Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85%. All specifications are under ambient temperature 20 (68 ), no load. Go to.com Further information on Temperature Chamber products is readily available on our website.

Temperature Chambers Specifications & Ordering Informations 102 Model TC-GU-300 Chamber volume (L / cu ft) 300 / 10.6 Control system Controller Temperature Time Refrigeration Cooler Heater Range ( / ) Cooling fuzzy control system Programmable, Touch screen type controller (5.7 Color monitor) -60 to 150 / -76 to 302 without humidity *best programmable control range : -50 to 140 / -58 to 284 Fluctuation 1) ( / ) at 40 0.3 / 0.54 Variation 1) ( / ) at 40 0.5 / 0.9 Heating (Min.) Cooling (Min.) System Refrigerant 60 From -60 to 120 (-76 to 248 ) 65 From 20 to -60 (68 to -76 ) on singe point control Mechanical single stage refrigerator system (air-cooled condenser) R-404A (1st step), R-23 (2nd step) Capacity (W) 3000 Plate fin cooler Ni-Cr Wire Heater Drying bulb (W) 2000 Temperature sensor Pt 100 Air flow Dimensions (W D H) Cable Port Interior Stainless steel #304 Exterior Stainless steel #304 Insulation Door Interior (mm / inch) Exterior (mm / inch) Viewing window (mm / inch) Net weight (kg / lbs) Polyurethane foam 100mm (3.94 ) Glass wool Tangent blower (90W) 600 630 800 / 23.6 24.8 31.5 1120 1070 1730 / 44.1 42.1 68.1 200 330 / 7.9 13.0 375 10 / 870.8 22.0 Basically one hole provided / 50mm (2.0 ) Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Electrical Requirements (230V) 60Hz / 1ph / 24.3A Cat. No. AAH81521 Electrical Requirements (230V) 50Hz / 1ph / 24.3A Cat. No. AAH81522 Electrical Requirements (380V) 60, 50Hz / 3ph / 8.3A Cat. No. AAH81528 1) Technical data. (according to DIN 12880, IEC 60068) Permissible ambient Condition: Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85%. All specifications are under ambient temperature 20 (68 ), no load.

Temperature (& ) Chambers Go to.com Further information on Temperature Chamber products is readily available on our website. 103 TH-TG Series TH-ICH Series

TEMPERATURE & HUMIDITY CHAMBERS TEMPERATURE & HUMIDITY CONTROL RANGE 104 TH-ICH TH-TG TH-TG Type (190 to 960L) 40 ~ 80% RH at 10 20 ~ 95% RH at 20 10 ~ 95% RH at 50 ~ 80 10 ~ 80% RH at 90. Dimensions (TH-TG / TH-ICH series) TH-ICH Type (300,700L) 40 ~ 80% RH at 15 35 ~ 85% RH at 20 30 ~ 85% RH at 30 20 ~ 85% RH at 40 ~ 85 Model Capacity W D H A B TH - TG - 180 190L (6.7 cu ft) 880mm (34.6 ) 945mm (37.2 ) 1465mm (57.7 ) 420mm (16.5 ) 880mm (34.6 ) TH - TG - 300 300L (10.6 cu ft) 1130mm (44.5 ) 945mm (37.2 ) 1520mm (59.8 ) 420mm (16.5 ) 905mm (35.6 ) TH - TG - 408 410L (14.5 cu ft) 1130mm (44.5 ) 1045mm (41.1 ) 1520mm (59.8 ) 520mm (20.5 ) 905mm (35.6 ) TH - TG - 800 760L (26.8 cu ft) 1220mm (48 ) 1175mm (46.3 ) 1965mm (77.4 ) 520mm (20.5 ) 1010mm (39.8 ) TH - TG - 1000 960L (33.9 cu ft) 1220mm (48 ) 1415mm (55.7 ) 1965mm (77.4 ) 635mm (25 ) 1010mm (39.8 ) TH - ICH- 300 300L (10.6 cu ft) 1130mm (44.5 ) 985mm (33.8 ) 1520mm (59.8 ) 460mm (18.1 ) 905mm (35.6 ) TH - ICH-800 760L (26.8 cu ft) 1220mm (48 ) 1215mm (47.8 ) 1965mm (77.4 ) 545mm (21.5 ) 1185mm (46.7 )

TEMPERATURE & HUMIDITY CHAMBERS The equipment for test results in compliance with the ICH Guideline. Stability Testing Q1A (R2)-ICH, TG Chamber series. Photostability Testing Q1B (Option 2)-ICH Chamber series. 105 Constructional features High quality 304 stainless steel exterior and interior. Casters for easy transport and installation. Convenient maintenance. - Available to check total operating time. Exclusive door lock & trim. Vice lock type door catch and foamed silicone packing ensure perfect chamber seal. Cable port for running in wires. Basic hole of 50mm diameter cable port is standard equipped on left side of chambers for wiring to the specimen. We also provide additional 50 or 80mm diameter cable port. (Optional) Water tank for easy water supply. - Maintenance can be done easily from the front side. Door locker. (Optional) Cyclic defrost function makes less influence to the Temperature & control for long term operation.(under 15 set value) Powerful 2 sirocco fans maintain constant air flow rate in the chamber. Control Operation Microprocess PID control / Auto-tuning / Calibration. Digital LCD display with touch-sensitive 7 keypads. Easy operation with wide LCD screen. - Temperature & humidity / timer settings and operating condition. The program patterns are memorized for 10 years even though the main power switch off, thanks to a PCB builtin battery. Expansionary parameters inputting. (Conveniently display by letters) Programming operation. Computer interface. - Available to save all data in Excel. - Provide a software. - The program information, setting values backup / recovery, and temperature / humidity values memory. - RS-232C as standard offer. Recorder. (Optional) - 6-point dots type recorder with digital display. - Digital recorder. (6-Channels) Additional TH-ICH 300, 800 Features This apparatus correctly transfers and controls each light after detecting it provides accurate data in the event of validation, equipped with light detectors. (UV light sensor / VIS light sensor) Sample has to be exposed to the light in which completely near UV energy of less than 200W-hr / m2 is provided to compare directly the results from overall intensity of less than 1.20 million lux-hr, drug substances and reagents. Convenient indication - displayed total fluorescent lamps & UV lamps operating time. Safety Functions Leakage breaker for power supply. Over current protector. Overheat protector. Switch-off after alarm for over heating. Door open warning alarm. Water empty. Vice lock door closing equipment. (Optional) Alarming when complete Photostability Test. (Only TH-ICH series)

TEMPERATURE & HUMIDITY CHAMBERS Specifications & Ordering Informations Model TH-TG-180 TH-TG-300 TH-TG-408 TH-TG-800 TH-TG-1000 Chamber volume (L / cu ft) 190 / 6.7 300 / 10.6 410 / 14.5 760 / 26.8 960 / 33.9 Controller PID control (LCD Type) 106 Temperature 1) Time Refrigeration Cooler Heater Sensor Air flow Range Without humidity ( / ) With humidity ( / ) Fluctuation 1) ( / ) at 40 / 60%RH Variation 1) ( / ) at 40 / 60%RH Range (%RH) Fluctuation 2) ( %RH) at 60%RH / 40 Variation 2) ( %RH) at 60%RH / 40 Heating 4) Cooling 4) 50min (-5 > 100 ) 120min (100 > -5 ) -5 ~ 100 / 23 ~ 212 +10 ~ 90 / 50 ~ 194 0.3 / 0.55 0.5 / 0.9 0.7 / 1.3 50min (-5 > 100 ) 120min (100 > -5 ) FULL RANGE : 10 ~ 95%RH 40 ~ 80 at 10 / 50 20 ~ 95 at 20 / 68 10 ~ 95 at 40 ~ 80 / 104 ~ 176 10 ~ 80 at 90 / 194 2.0 3.0 50min (-5 > 100 ) 120min (100 > -5 ) Air-cooled R-404A 55min (-5 > 100 ) 145min (100 > -5 ) System Refrigerant Capacity (W) 150 250 250 470 470 Copper plate fin cooler Ni-Cr Wire Heater / SUS Tube Heater Drying bulb (W) 1000 1500 1500 2300 2300 bulb (W) 1000 1200 1200 2000 2000 Temperature Pt 100 Electronic sensor (Free of drying a wet pack and good response time) Internal External 2 set of sirocco fan (2 60 W) : Vertical type SUS #304 (2B polish) SUS #304 (Hairline finish) & Steel, 2.0t, Double painted & baked Insulation Polyurethane (70mm / 2.76 ) Door Operating temperature Water tank Interface Cable port Glasswool 18 ~ 30 / 64.4 ~56, 85%RH (Non-corrosive and pure place) Capacity (L / cu ft) 15 / 0.53 Water quality Viewing Window (mm / inch) Dimension (W D H) Internal (mm / inch) External (mm / inch) 500 650 600 / 19.7 25.6 23.6 880 945 1465 / 34.6 37.2 57.7 ph6.2 ~ 7.2, Electrical conductivity 20 / cm to below Basically RS-232C, [RS-485 : Optional] Basically one hole provided / 50mm (2.0 ), Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) 750 650 650 / 29.5 25.6 25.6 1130 945 1520 / 44.5 37.2 59.8 230 340 / 9.1 13.4 (Option) 750 850 650 / 29.5 33.5 25.6 1130 1045 1520 / 44.5 41.1 59.8 750 880 1160 / 29.5 34.6 45.7 1220 1175 1965 / 48.0 46.3 77.3 55min (-5 > 100 ) 145min (100 > -5 ) 750 1110 1160 / 29.5 43.7 45.7 1220 1415 1965 / 48.0 55.7 77.4 Net weight (kg / lbs) 220 10 / 485 22 250 10 / 485 22 280 10 / 617 22 360 10 / 794 22 410 10 / 904 22 AC230V, 1ph, 60Hz 13.1 A 15.4 A 15.4 A 24.5 A 24.5 A Max. Power Cat.No. AAHC2001K AAHC2011K AAHC2021K AAHC231K AAHC2041K consumption AC230V, 1ph, 50Hz 12.4 A 14.7 A 14.7 A 23.5 A 23.5 A Cat.No. AAHC2002K AAHC2012K AAHC2022K AAHC2032K AAHC2042K 1) All specifications are under ambient temperature 20 (68 ), no load. 2) Technical data. (according to DIN 12880, IEC 60068) 3) The value is measured on the center of chamber at the point of vertical direction. 4) Up to 98% of the set value. Go to.com Further information on Temperature Chamber products is readily available on our website.

TEMPERATURE & HUMIDITY CHAMBERS Specifications & Ordering Informations Model TH-ICH-300 TH-ICH-800 Chamber volume (L / cu ft) 300 / 10.6 760 / 26.8 Controller PID control (LCD Type) Without -5 ~ 85 / 23~185 without Light humidity ( / ) 0 ~ 85 / 32~185 with Light Temperature 1) Light source (ICH Q1B option 2) Range With humidity ( / ) Fluctuation 1) ( / ) at 40 / 60%RH Variation 1) ( / ) at 40 / 60%RH Range (%RH) Fluctuation 2) ( %RH) at 60%RH / 40 +15 ~ 85 / 59~185 with Light 0.3 / 0.55 0.3 / 0.55 0.5 / 0.9 0.7 / 1.3 FULL RANGE : 20 ~ 85%RH 40 ~ 80 at 15 / 59 35 ~ 85 at 20 / 68 30 ~ 85 at 30 / 86 20 ~ 85 at 40 ~ 75 / 104 ~ 167 20 ~ 85 at 85 / 185 Variation 2) ( %RH) at 60%RH / 40 5.0 Cool white 3) 6,000 lux 6,500 lux Ultraviolet-A 3) 4.5 W/ 5.0 W/ Light Uniformity Typical Time Required to Reach ICH Recommendation of 1.2 million lux-hr VIS.: 10% UVA : 15% 200Hr 3.0 VIS.: 15% UVA : 15% 184Hr Typical Time Required to Reach ICH Recommendation of 200 W-hr/m 2 50Hr 40Hr Time Refrigeration Cooler Heater Sensor Air flow Heating 4) 25min (20 > 85 ) 30min (20 > 85 ) Cooling 4) 35min (20 > -5 ) 40min (20 > -5 ) System Air-cooled Refrigerant R-404A Capacity (W) 250 470 Copper plate fin cooler Ni-Cr Wire Heater / SUS Tube Heater Drying bulb (W) 1500 2300 bulb (W) 1200 2000 Temperature Pt 100 Electronic sensor (Free of drying a wet pack and good response time) Internal External 2 set of sirocco fan (2 60 W) : Vertical type SUS #304 (2B polish) SUS #304 (Hairline finish) & Steel, 2.0t, Double painted & baked Insulation Polyurethane (70mm / 2.76 ) Door Operating temperature Water tank Interface Cable port Dimension (W D H) EPDM Sheet 18 ~ 30 / 64.4 ~56, 85%RH (Non-corrosive and pure place) Capacity (L / cu ft) 15 / 0.53 Water quality ph6.2 ~ 7.2, Electrical conductivity 20 / cm to below Basically RS-232C, [RS-485 : Optional] Basically one hole provided / 50mm (2.0 ), Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Internal (mm / inch) 750 650 650 / 29.5 25.6 25.6 750 880 1160 / 29.5 34.6 45.7 External (mm / inch) 1130 985 1520 / 44.5 38.8 59.8 1220 1215 1965 / 48.0 47.8 77.4 Net weight (kg / lbs) 280 10 / 617 22 400 10 / 882 22 AC220V, 1ph, 60Hz 15.4 A 24.5 A Max. Power Cat.No. AAHC1001K AAHC1011K consumption AC230V, 1ph, 50Hz 14.7 A 23.5 A Cat.No. AAHC1002K AAHC1012K 107 1) All specifications are under ambient temperature 20 (68 ), no load. 2) Technical data. (according to DIN 12880, IEC 60068) 3) The value is measured on the center of chamber at the point of vertical direction. 4) Up to 98% of the set value.

Temperature (& ) Chambers - Tabletop type Go to.com Further information on Temperature Chamber products is readily available on our website. 108 TH-ME / TH-PE / TC-ME Series In the year of 2010, this products design can be changed without prior notice.

Temperature (& ) Chambers - Tabletop type Temperature & control range (TH-ME/ TH-PE series only) Relative % RH TH-PE-025/065/100 TH-ME-025/065/100 (Including TH-PE control range) 85 Temperature 95%RH 35%RH 30%RH TH-ME type 55 ~ 95% RH at 15 40 ~ 95% RH at 30 30 ~ 95% RH at 70 30 ~ 95% RH at 70~85 TH-PE type 60 ~ 95% RH at 15 45 ~ 95% RH at 30 35 ~ 95% RH at 70 35 ~ 95% RH at 70~80 109 Dimensions (TH-ME / TH-PE / TC-ME series) Models Capacity W D H A B TH-ME 25L (0.9cu ft) 520mm (20.5 ) 760mm (29.9 ) 867mm (34.1 ) 200mm (7.9 ) 467mm (18.4 ) TH-PE 65L (2.3cu ft) 570mm (22.4 ) 890mm (35.0 ) 1010mm (39.8 ) 235mm (9.3 ) 540mm (21.2 ) TC-ME 100L (3.53cu ft) 650mm (25.6 ) 1000mm (39.4 ) 1050mm (41.3 ) 263mm (10.4 ) 557mm (21.9 )

Temperature (& ) Chambers - Tabletop type Operating & Constructional features (TH-ME / TH-PE series only) 110 User-friendly design Small size & light weight. Compact design with high performance. Inner glass door Select your optimum chamber from a full variation. - The series provide three variations in temperature (& humidity) range of -20 to 150, 0 to 120, -20 to 120 / upmost 20 to 95% RH, and three capacities of 20L, 65L, and 100L, with a total 9 models altogether. Efficient system with durable materials. - The evaporating system for better thermal efficiency with corrosion-resistant materials. - The heating system with minimized potential heat when heating or cooling for prompt reaction time and advanced performance. Water tank for easy water supply. - Maintenance can be done easily from the front side. Inner glass door for observation. - A tempered glass door provides a clear view of your specimen during testing. Cable port for running in wires. - Basic hole of 50mm diameter cable port is standard equipped on left side of chambers for wiring to the specimen. We can also provide additional 50 or 80mm diameter cable port. (Optional) Optional stand for space-saving layout. - For use in limited space, we provided stand with casters for staking up two chambers. Be sure to secure the stand onto floor with earthquake resistant fitting for your safety when using stand. Controller Safety functions Leakage breaker for power supply. Over current protector. Overheat / overcool protectors. Switch-off after alarm for over heating. Door opening alarm. Water empty. (TH-ME / TH-PE only) Portable Digital Recorder (optional)

Temperature (& ) Chambers - Tabletop type Control operation Microprocess PID control / Auto-tuning / Calibration. Digital LCD display with touch-sensitive 7 keypads. Easy operation with wide LCD screen. - Temperature & humidity / timer settings and operating condition. The program patterns are memorized for 10 years even though the main power switch off, thanks to a PCB built-in battery. Expansionary parameters inputting. (conveniently display by letters) Programming operation. Description Programmable pattern capacity 30 Pattern repeat time 999 Max. segments per a pattern 100 Available max. segments* 300 Programmable process time per a segment TH-ME / PE, TC-ME series 0 to 99 hr 59 min * Even though the max. segments per a pattern are 100, available total segments are up to 300 not 3000, so you need to arrange the number of segment and patterns properly. Computer interface. (optional) - Available to save all data in Excel. - Provide a software. - The program information, setting values backup / recovery, and temperature / humidity values memory. Water Tank 111 Recorder. (optional) - 6-point dots type recorder with digital display. By using RS-485 communication port offer maximum 9 sets of Temperature & chamber can be connected by one PC. (optional) Multi-control Display Single-control Display Exclusive stand for the chamber Program setting Display Graph Display

Temperature & Chambers - Tabletop type Specifications & Ordering Informations Model TH-ME-025 TH-ME-065 TH-ME-100 112 Chamber volume (L / cu ft) 25 / 0.9 65 / 2.3 100 / 3.53 Control system BDBC2 system - Balanced Dehumidifying & Bath Cooling control Controller Program controller (LCD type) Temperature Time Refrigeration Cooler Heater Sensor Air flow Water tank Dimensions (W D H) Cable port Interface Range ( / ) Fluctuation 1) ( / ) at 25 / 60%RH Variation 1) ( / ) at 25 / 60%RH Heating - without humidity (Min.) Cooling - without humidity (Min.) Range (%RH) Fluctuation 1) ( %RH) at 60%RH / 55 Variation 1) ( %RH) at 60%RH / 55 System Refrigerant -20 to 120 / -4 to 248 without humidity 0.2 / 0.36 0.3 / 0.55 0.2 / 0.36 0.3 / 0.55 0.3 / 0.55 0.3 / 0.55 55 From -15 to 120 (5 to 248 ) 60 From 20 to -15 (68 to 5 ) on singe point control * 55 to 95 at 15 (59 ) 40 to 95 at 30 (86 ) 1.6 0.4 0.5 3 3 3 Mechanical single stage refrigerator system (air-cooled condenser) R-404A Capacity (W) 250 250 375 Plate fin cooler (cooper) Ni-Cr Wire Heater / SUS sheath Heater Drying bulb (W) 800 1000 1000 bulb (W) 800 800 1000 Temperature Pt 100 Electronic sensor - Free of drying a wet pack and good reaction time Interior Stainless steel #304 Exterior Insulation Door Steel, 1.0mm (0.04 ) / Double painted & baked Polyurethane foam 50mm (1.97 ) Glass wool Sirocco fan (60W) Capacity (L / cu ft) 5 / 0.18 6 / 0.21 9 / 0.32 Water quality ph6.2 to 7.2 / Electrical conductivity 20 /cm to below Interior (mm / inch) 350 220 350 / 13.8 8.7 13.8 400 330 495 / 15.7 13.0 19.5 500 380 530 / 19.7 15.0 20.9 Exterior (mm / inch) 500 760 850 / 19.7 29.9 33.5 550 890 1000 / 21.7 35.0 39.4 650 1000 1030 / 25.6 39.4 40.6 Net weight (kg / lbs) 80 5 / 176.0 11.0 110 5 / 242.0 11.0 130 5 / 286 11.0 Basically one hole provided / 50mm (2.0 ) Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional] Electrical Requirements (230V) 60Hz / 1ph / 12.3A 60Hz / 1ph / 13.2A 60Hz / 1ph / 14.4A Cat. No. AAH82111 AAH82121 AAH82131 Electrical Requirements (230V) 50Hz / 1ph / 11.9A 50Hz / 1h / 12.7A 50Hz / 1ph / 13.8A Cat. No. AAH82112 AAH82122 AAH82132 1) Technical data. (according to DIN 12880, IEC 60068) * 80mm cable access hole is NOT available for 25L chamber. (TH-ME-025) * Above the dimensions are NOT included size of attached accessories. Permissible ambient Condition : Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85% All specifications are under ambient temperature 20 (68 ), no load.

Temperature & Chambers - Tabletop type Specifications & Ordering Informations Model TH-PE-025 TH-PE-065 TH-PE-100 Chamber volume (L / cu ft) 25 / 0.9 65 / 2.3 100 / 3.53 Control system Controller Temperature Time Refrigeration Cooler Heater Sensor Air flow Water tank Dimensions (W D H) Cable port Interface Range ( / ) Fluctuation 1) ( / ) at 25 / 60%RH Variation 1) ( / ) at 25 / 60%RH Heating - without humidity (Min.) Cooling - without humidity (Min.) Range (%RH) Fluctuation 1) ( %RH) at 60%RH / 55 Variation 1) ( %RH) at 60%RH / 55 System Refrigerant BDBC2 system - Balanced Dehumidifying & Bath Cooling control Program controller (LCD type) 0 to 100 / 32 to 212 without humidity 0.2 / 0.36 0.3 / 0.55 0.2 / 0.36 0.3 / 0.55 0.3 / 0.55 0.3 / 0.55 40 From 0 to 120 (32 to 248 ) 30 From 20 to 0 (68 to 32 ) on singe point control * 60 to 95 at 15 (59 ) 45 to 95 at 30 (86 ) 1.6 0.4 0.5 3 3 3 Mechanical single stage refrigerator system (air-cooled condenser) R-404A Capacity (W) 250 250 375 Plate fin cooler (cooper) Ni-Cr Wire Heater/ SUS sheath Heater Drying bulb (W) 800 1000 1000 bulb (W) 800 800 1000 Temperature Pt 100 Electronic sensor - Free of drying a wet pack and good reaction time Interior Stainless steel #304 Exterior Insulation Door Stainless steel, 1.0mm (0.04 ) / Double painted & baked Polyurethane foam 50mm (1.97 ) Glass wool Sirocco fan (60W) Capacity (L / cu ft) 5 / 0.18 6 / 0.21 9 / 0.32 Water quality ph6.2 to 7.2/ Electrical conductivity 20 /cm to below Interior (mm / inch) 350 220 350 / 13.8 8.7 13.8 400 330 495 / 15.7 13.0 19.5 500 380 530 / 19.7 15.0 20.9 Exterior (mm / inch) 500 760 850 / 19.7 29.9 33.5 550 890 1000 / 21.7 35.0 39.4 650 1000 1030 / 25.6 39.4 40.6 Net weight (kg / lbs) 80 5 / 176.0 11.0 110 5 / 242.0 11.0 130 5 / 286 11.0 Basically one hole provided / 50mm (2.0 ) Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional] Electrical Requirements (230V) 60Hz / 1ph / 12.3A 60Hz / 1ph / 13.2A 60Hz / 1ph / 14.4A Cat. No. AAH82211 AAH82221 AAH82231 Electrical Requirements (230V) 50Hz / 1ph / 11.9A 50Hz / 1h / 12.7A 50Hz / 1ph / 13.8A Cat. No. AAH82212 AAH82222 AAH82232 113 1) Technical data. (according to DIN 12880, IEC 60068) * 80mm cable access hole is NOT available for 25L chamber. (TH-PE-025) * Above the dimensions are NOT included size of attached accessories. Permissible ambient Condition : Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85% All specifications are under ambient temperature 20 (68 ), no load. Go to.com Further information on Temperature Chamber products is readily available on our website.

Temperature Chambers - Tabletop type Specifications & Ordering Informations Model TC-ME-025 TC-ME-065 TC-ME-100 114 Chamber volume (L / cu ft) 25 / 0.9 65 / 2.3 100 / 3.53 Control system Controller Temperature Time Refrigeration Cooler Heater Cooling PID control system Program controller (LCD type) Range ( / ) -20 to 120 / -4 to 248 Program control ( / ) -15 to 120 / -5 to 248 Fluctuation 1) ( / ) at 100 Variation 1) ( / ) at 100 Heating (Min.) 0.4 / 0.72 0.3 / 0.55 0.3 / 0.55 2.0 / 3.60 1.9 / 3.42 1.8 / 3.24 55 From -15 to 120 (5 to 248 ) Cooling (Min.) 60 From 20 to -15 (68 to 5 ) on singe point control * System Refrigerant Mechanical single stage refrigerator system (air-cooled condenser) R-404A Capacity (W) 250 250 375 Plate fin cooler (cooper) Ni-Cr Wire Heater Drying bulb (W) 800 1000 1000 Temperature sensor Pt 100 Air flow Dimensions (W D H) Interior Stainless steel #304 Exterior Insulation Door Stainless steel, 1.0mm (0.04 ) / Double painted & baked Polyurethane foam 50mm (1.97 ) Glass wool Sirocco fan (60W) Interior (mm / inch) 350 220 350 / 13.8 8.7 13.8 400 330 495 / 15.7 13.0 19.5 500 380 530 / 19.7 15.0 20.9 Exterior (mm / inch) 500 760 850 / 19.7 29.9 33.5 550 890 1000 / 21.7 35.0 39.4 650 1000 1030 / 25.6 39.4 40.6 Net weight (kg / lbs) 80 5 / 176.0 11.0 110 5 / 242.0 11.0 130 5 / 286 11.0 Cable port Interface Basically one hole provided / 50mm (2.0 ) Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional] Electrical Requirements (230V) 60Hz / 1ph / 8.8A 60Hz / 1ph/ 9.7A 60Hz / 1ph / 10.5A Cat. No. AAH86011 AAH86021 AAH86031 Electrical Requirements (230V) 50Hz / 1ph / 8.4A 50Hz / 1h / 9.3A 50Hz / 1ph / 10.0A Cat. No. AAH86012 AAH86022 AAH86032 1) Technical data. (according to DIN 12880, IEC 60068) * 80mm cable access hole is NOT available for 25L chamber. (TC-ME-025) * Above the dimensions are NOT included size of attached accessories. Permissible ambient Condition : Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85% All specifications are under ambient temperature 20 (68 ), no load.

Temperature & Chamber Go to.com Further information on Temperature Chamber products is readily available on our website. 115 Fingerprint Development Chamber Temperature & control range Relative % RH TH-PF-100 TH-PF-100 80 ~ 90% RH at 40 65 ~ 95% RH at 50 50 ~ 95% RH at 60 50 ~ 90% RH at 90 Temperature

Temperature & Chamber Fingerprint Development Chamber 116 Exceptional design for Ninhydrin, DFO and other fingerprint development processes. Highly precise control by microprocessor PID controller for rapid development. Advanced safety features for protect evidences. Clear watch with LED light strip and heated glass window. Operating & Constructional features [Fingerprint Development Chamber] Constructional Features Small size & light weight. Compact design with high performance. Efficient system with durable materials. - The evaporating system for better thermal efficiency with corrosion-resistant materials. - The heating system with minimized potential heat when heating or cooling for prompt reaction time and advanced performance. Stainless steel interior - High quality & Corrosion-resistant Water tank for easy water supply. - Maintenance can be done easily from the front side. (Optional Direct water system.) Large viewing window - A tempered glass door provides a clear view of your specimen during testing. Vice lock type door catch and foamed silicone packing ensure perfect chamber seal. Cable port for running in wires. - Basic hole of 50mm diameter cable port is standard equipped on left side of chambers for wiring to the specimen. We can also provide additional 50 or 80mm diameter cable port. (optional) Optional stand for space-saving layout. - For use in limited space, we provided stand with casters for staking up two chambers. Be sure to secure the stand onto floor with earthquake resistant fitting for your safety when using stand. SAFETY FUNCTIONS Key lockable door for your evidences. Leakage breaker for power supply. Over current protector. Overheat protector. Switch-off after alarm for overheating. Door open warning alarm. Water empty. Control Board Control Operation Intuitive Control Panel. - Sight Lamp, Window Clean, Water Level indicators. Microprocess PID control / Auto-tuning / Calibration. - Precise temperature & humidity control. - Faster fingerprints development. - Rapid recovery time after door openings. Digital LCD display with touch-sensitive 7 keypads. Easy operation with wide LCD screen. - Temperature & humidity / timer settings and operating condition. Digital Timer with acoustic alarm. - Start / Stop button for easy operation. - Digital display for time remaining. - Set time expiring alarm. Programming operation. The program patterns are memorized for 10 years even though the main powers switch off, thanks to a PCB built-in battery. Expansionary parameters inputting. (Conveniently display by letters.) Computer interface. - Available to save all data in Excel. - Provide software. - The program information, setting values backup / recovery, and temperature / humidity values memory. - RS-232C as standard offer. Recorder. (Optional) - 6-point dots type recorder with digital display.

Temperature & Chamber 117 Large viewing window with LED lights on both sides Heated glass window eliminates condensation. Specifications & Ordering Informations (Fingerprint development chamber) Chamber volume (L / cu ft) 100 / 3.53 Controller Temperature Heater Sensor Air flow Water tank Viewing Window (mm / inch) Cable port Interface Dimension (W D H) PID control (LCD Type) Range ( / ) 40 ~ 100 / 104 ~ 212 Fluctuation ( / ) at 100 0.5 / 0.9 Variation ( / ) at 100 0.5 / 0.9 Range [%RH] Fluctuation ( %RH) 3.0 Variation ( %RH) 3.0 Drying bulb bulb FULL RANGE : 50 ~ 90%RH 80 to 90 at 40 65 to 95 at 50 50 to 90 at 90 Ni-Cr Wire Heater / SUS cartridge Heater 400W 400W Temperature Pt 100 Internal External Insulation Door Electronic sensor (free of drying a wet pack and good response time) 2 set of sirocco fan (60W) SUS #304 (2B polish) SUS #304 & Steel, 1.0t, Double painted & baked Polyurethane (70mm) Glasswool capacity (L / cu ft) 9 / 0.32 quality Internal (mm / inch) ph6.2 ~ 7.2, Electrical conductivity 20 / cm to below 280 430 / 11.02 16.9 Basically one hole provided / 50mm (2.0") Optionally max. two holes available/ 50 or 80mm (2.0 or 3.2") Basically RS-232C [RS-485[Maximum 9 Units Control]-Optional] 500 380 530 / 1.97 15.0 20.9 External (mm / inch) 670 845 1045 / 26.4 33.3 41.15 Weight (kg / ibs) Electrical Requirements AC230V, 1ph, 60Hz 4.5A Cat. No. Electrical Requirements AC230V, 1ph, 50Hz 4.3A Cat. No. Model Water Tank included Easy maintenance. Optional Direct water system. 115kg 5kg / 253.5 11.0 AAH82331 AAH82332 Key lockable door for your evidences. TH-PF-100 Permissible ambient conditions : Temperature 18 to 30 C(64.4 to 86.0 F), Maximum relative humidity 85% Recommended ambient temperature : +20 C(68 F) All specifications are under ambient temperature 20 (68 ), no load.

Clean Temperature & Chambers Go to.com Further information on Temperature Chamber products is readily available on our website. 118 TH-CR-270 Temperature & control range Relative % RH TH-CR-270 90% RH TH-CR-270 50 ~ 80% RH at 20 40 ~ 90% RH at 25 35 ~ 90% RH at 40 30 ~ 90% RH at 85 85 Temperature

Clean Temperature & Chambers Dimensions (TH-CR-270) 119 Models Capacity W D H * A B TH-CR-270 270L (9.5 cu ft) 1180mm (46.5 ) 1120mm (44.1 ) 1935mm (76.1 ) 325mm (12.8 ) 1155mm (45.5 ) Operating & Constructional features User-friendly design Standard clean environmental test chambers. Silicone-free safe construction. High quality 304 stainless steel exterior and interior. Casters for easy transport and installation. Convenient maintenance - available to check total operating time. Exclusive door lock & trim. - Vice lock type door catch and foamed silicone packing ensure perfect chamber seal. - Door open warning alarm. Inner door. - Optional inner glass door has four hole to handle inside specimen without opening the door. Exhaust duct. - Exhaust duct is located at the upper right side of the unit. Recorder. (optional) - 6-point dots type recorder with digital display. Cartridge type tank for easy water supply. - Maintenance can be done easily from the front side. - A center window allow to check the amount of water remaining easily. Viewing window for observation. - A tempered window provides a clear view of your specimen during testing. - Improved lighting provided. Cable port for running in wires. - Basic hole of 50mm diameter cable port is standard equipped on left side of chambers for wiring to the specimen. We also provide additional 50 or 80mm diameter cable port. (Optional) Easy cleaning of condenser air-filter. - To prevent deterioration of refrigerator, keep filtering dust by periodical filter cleaning. Inner chamber

Clean Temperature & Chambers 120 Capable for the best cleaned temperature and humidity chamber! Class 100 cleanness is achieved by employing a HEPA filter and a bottom-to-up laminar circulation system. Operating & Constructional features Control operation Microprocess PID control / Auto-tuning / Calibration. Languages support in three kinds of English, Chinese, and Korean. Optimize CPU logic control system. - Optimum control for temperature / humidity with economical control in power consumption. Touch screen type monitor. - 5.7-inch Color LCD with interactive input system using touch keys. - Temperature & humidity / timer settings and operating condition. - Temperature, humidity, other operating parameters, and a record of previous operation are also displayed in graph form. - Easily recognizable set values; set point (SP) / proportional value (PV) are also added on the color LED controller. Control Panel Programming operation. Description TH-CR-270 Programmable pattern capacity 120 Pattern repeat time 999 Max. segments per a pattern 100 Available max. segments * 1200 Programmable process time per a segment 0 to 99 hr 59 min * Even though the max. segments per a pattern are 100, available total segments are up to 1200 not 12000, so you need to arrange the number of segment and patterns properly. Computer interface. (optional) - Computer interface. (optional) - Available to save all data in Excel. - Provide a software. - The program information, setting values backup / recovery, and temperature / humidity values storage. Door Catch & Trim Safety functions Leakage breaker for power supply. Over current protector. Overheat/ overcool protectors. Switch-off after alarm for over heating. Water empty. Door opening alarm. Vice lock door closing equipment. Air-filter

Clean Temperature & Chambers Go to.com Further information on Temperature Chamber products is readily available on our website. Specifications & Ordering Informations 121 Model Chamber volume (L / cu ft) 270 / 9.5 Control system Controller Temperature Time Range ( / ) -35 to 100 / -31 to 212 Fluctuation 1) ( / ) at 40 / 60%RH 0.5 / 0.9 Variation 1) ( / ) at 40 / 60%RH 0.5 / 0.9 Heating - without humidity (Min.) Cooling - without humidity (Min.) Range (%RH) Fluctuation 1) ( %RH) 3 Variation 1) ( %RH) at 60%RH 3 TH-CR-270 BDBC2 system - Balanced Dehumidifying & Bath Cooling control Programmable, Touch screen type controller (5.7 Color monitor) Local controller (Fixed - command control) 60 From -35 to 120 (-31 to 248 ) 65 From 20 to -35 (68 to -31 ) 50 to 80 at 20 (68 ) 40 to 90 at 25 (77 ) 35 to 90 at 40 (104 ) 30 to 90 at 85 (185 ) Cleanliness Class 100 (ISO 14644-1) Refrigeration Cooler Heater Sensor Air flow Water supply Dimensions (W D H) Cable port System Refrigerant Mechanical single stage refrigerator system (air-cooled condenser) R-404A Capacity (W) 1500 Drying bulb (W) 2000 bulb (W) 2000 Temperature Pt 100 Plate fin cooler Ni-Cr Wire Heater / SUS sheath Heater Interior Stainless steel #304 Exterior Insulation Door *Silicon Free (optional) Capacity Water quality Interior (mm / inch) Exterior (mm / inch) Viewing windows (mm / inch) Net weight (kg / lbs) Electronic sensor - Free of drying a wet pack and good reaction time Stainless steel #304 (Base & Control panels are made of Stainless steel with powder coating) Polyurethane Glass wool EPDM for door packing, chamber sealing and tube Poly Urethane for DI water inlet & drainage Sirocco fan 15L (0.53cu ft) - Cartridge type ph6.2 to 7.2 / Electrical conductivity 20 /cm to below 600 700 648 / 23.6 27.6 25.4 1180 1120 1935 / 46.5 44.1 76.2 200 330 / 7.9 13.0 400 10 / 881.8 22.0 Basically one hole provided / 50mm (2.0 ) Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Electrical Requirements 230V / 60Hz / 1ph / 29.0A 230V / 50Hz / 1ph / 29.0A Cat. No. AAH83011 AAH83012 Electrical Requirements (380V) 380 / 50Hz / 3ph / 9.6A Cat. No. AAH83018 1) Technical data. (according to DIN 12880, IEC 60068) Permissible ambient Condition: Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85% All specifications are under ambient temperature 20 (68 ), no load. Upon request, other sizes of chambers are available. Please contact with us.

Accessories & Options for TH/ TC series 122 Viewing window Inner door Recorder Warning signal light Viewing window A observation window is installed ONLY on all floor type chambers. (TH / TC series and TH-CR-270 without TH-ICh series) A tempered dual windows provided a clear view of your specimen during testing. Improved lighting provided. Inner door A inner glass door is provided inside of the chamber door so that specimens can be observed. Applicable to some of floor type chambers. (Table top - without hand entry ports.) Temperature and recorder 6-point dots type, channels type. Digital display. Water supply Water supply system to supply pure water for humidification. - Maintenance can be done easily from the front side. Cable port A through hole of 50 or 80mm dia. (2.0 or 3.2" dia.) is provided on the wall of chamber to allow electrical cables to be introduced into the chamber. A 50mm hole is provided, maximum two holes (50 or 80mm) are optional. Water purifier Water purifier with reverse osmosis membrane. Can be installed optionally. Shelf Wire and perforated type shelves (included shelf brackets) are made of durable stainless steel. Standard specification shelves and shelf brackets are added as required. Warning signal light A signal light to light up when malfunction occurs. Can be located upper plate of unit. Tabletop type chambers (TH-ME / TH-PE / TC-ME series / TH-PF-100) Cat. No. Description Models TH-ME TH-PE TH-PF TC-ME AAA8T504 Recorder (6 points) AAA8T505 Recorder (Digital, 6 channels) AAA8T540 RS-232C interface converter included a cable (5m / 16.4ft) AAA8T541 RS-485 interface converter included a cable (5m / 16.4ft) AAA8T542 Interface cable (5m / 16.4ft) AAA8T550 Warning signal lamp RTD679 Wire shelf for TH-ME-025 / TH-PE-025 / TC-ME-025 * - RTD680 Wire shelf for TH-ME-065 / TH-PE-065 / TC-ME-065 * - RTD681 Wire shelf for TH-ME-100 / TH-PE-100 / TH-PF-100 / TC-ME-100 * AAA80602-6 Perforated shelf for TH-ME-025 / TH-PE-025 / TC-ME-025 * - AAA80602-7 Perforated shelf for TH-ME-065 / TH-PE-065 / TC-ME-065 * - AAA80602-8 Perforated shelf for TH-ME-100 / TH-PE-100 / TH-PF-100/ TC-ME-100 * AAA8T610 Cable port ( 50mm / 2.0 ) AAA8T611 Cable port ( 80mm / 3.2 ) AAA80631 Stand for TH-ME-025 / TH-PE-025 / TC-ME-025 - AAA80632 Stand for TH-ME-065 / TH-PE-065 / TC-ME-065 - AAA80633 Stand for TH-ME-100 / TH-PE-100 / TH-PF-100 / TC-ME-100 AAA80634 Two step stand for TH-ME-025 / TH-PE-025 / TC-ME-025 - AAA80635 Two step stand for TH-ME-065 / TH-PE-065 / TC-ME-065 - AAA8T621 Water purifier RTD0794 sensor - CFA1910 Temperature sensor (RTD type) 80mm cable access hole is NOT available for 25L chamber. (TH-ME/PE-25, TC-ME-25) Wire & Perforated shelves for Tabletop type chambers * Only for wire shelf. Models Description Included* Maximum Space Dimensions (W L) TH-ME-025 / TH-PE-025 / TC-ME-025 2 7 20mm (0.8 ) 195 310mm (7.7 12.2 ) TH-ME-065 / TH-PE-065 / TC-ME-065 2 10 20mm (0.8 ) 280 360mm (11.0 14.2 ) TH-ME-100 / TH-PE-100 / TH-PF-100 / TC-ME-100 2 10 20mm (0.8 ) 330 460mm (13.0 18.1 )

Accessories & Options for TH/ TC series Floor type chambers (TH-G / TH-I / TH-TG / TH-ICH / TC-G series) Cat. No. Description Models TH-G TH-I TC-G TH-TG TH-ICH TH-CR 270 AAA8T500 Recorder (6 points) AAA8T505 Recorder (Digital, 6 channels) AAA8T541 Interface converter included a cable (5m / 16.4ft) AAA8T542 Interface cable (5m / 16.4ft) AAA80550 Warning signal lamp AAA81552 Inner glass door (only for 180L chambers) - - - AAA81551 Inner glass door (only for 270, 300, 408L chambers) - - - EDA8212 Wire shelf for TH-G-180 / TH-I-180 / TC-G-180 * - - - EDA8213 Wire shelf for TH-G-300 / TH-I-300 / TC-G-300 * - - - EDA8214 Wire shelf for TH-G-408 / TH-I-408 / TC-G-408 * - - - EDA8215 Wire shelf for TH-G-800 / TH-I-800 / TC-G-800 * - - - - - EDA8216 Wire shelf for TH-G-1000 / TH-I-1000 / TC-G-1000 * - - - - - RTD1195 Wire shelf for TH-TG-180 - - - - - RTD1196 Wire shelf for TH-TG / ICH-300 - - - - RTD1197 Wire shelf for TH-TG-408 - - - - - RTD1198 Wire shelf for TH-TG / ICH-800 - - - - RTD1199 Wire shelf for TH-TG-1000 - - - - - STT1040 Wire shelf for TH-CR-270 * - - - - - AAA80602-1 Perforated shelf for TH-G-180 / TH-I-180 / TC-G-180 * - - - AAA80602-2 Perforated shelf for TH-G-300 / TH-I-300 / TC-G-300 * - - - AAA80602-3 Perforated shelf for TH-G-408 / TH-I-408 / TC-G-408 * - - - AAA80602-4 Perforated shelf for TH-G-800 / TH-I-800 / TC-G-800 * - - - - - AAA80602-5 Perforated shelf for TH-G-1000 / TH-I-1000 / TC-G-1000 * - - - - - AAA80604-1 Perforated shelf for TH-TG-180 - - - - - AAA80604-2 Perforated shelf for TH-TG / ICH-300 - - - - AAA80604-3 Perforated shelf for TH-TG-408 - - - - - AAA80604-4 Perforated shelf for TH-TGTG / ICH-800 - - - - AAA80604-5 Perforated shelf for TH-TG-1000 - - - - - AAA80630-1 Perforated shelf for TH-CR-270 * - - - - - AAA8T610 Cable port ( 50mm / 2.0 ) AAA8T611 Cable port ( 80mm / 3.2 ) AAA8T621 Water purifier AAA80622 Water cartridge tank RTD0794 sensor CFA1910 Temperature sensor (RTD type) RTD1190 Fluorescent Lamp(Cool White) for TH-ICH-300 - - - - - RTD1191 Fluorescent Lamp(Cool White) for TH-ICH-800 - - - - - RTD1188 UVA Lamp for TH-ICH-300 - - - - - RTD1189 UVA Lamp for TH-ICH-800 - - - - - AAA80680 THE-680 UV Sensor TH-ICH - - - - - AAA80681 THE-681 Illumination Sensor for TH-ICH - - - - - EDA9175 ULPA filter (optional) - - - - - EDA9184 HEPA filter (1EA included) - - - - - AAA80661 Door lock device - - - - AAA80620 Direct water system - - - - 123 Wire & Perforated shelves for Floor type chambers Models Description Included* Maximum Space Dimensions (W L) TH-G-180 / TH-I-180 / TC-G-180 2 9 40mm (1.6 ) 463 518mm (17.2 20.4 ) TH-G-300 / TH-I-300 / TC-G-300 2 10 40mm (1.6 ) 518 558mm (20.4 22.0 ) TH-G-408 / TH-I-408 / TC-G-408 2 10 40mm (1.6 ) 560 740mm (22.0 29.1 ) TH-G-800 / TH-I-800 / TC-G-800 2 14 40mm (1.6 ) 750 960mm (30.0 37.8 ) TH-G-1000 / TH-I-1000 / TC-G-1000 2 14 40mm (1.6 ) 950 960mm (37.4 37.8 ) TH-TG-180 2 7 60mm (2.4 ) 458 608 (18 23.9) TH-TG / ICH-300 2 8 60mm (2.4 ) 708 608 (27.9 23.9) TH-TG-408 2 8 60mm (2.4 ) 708 808 (27.9 31.8) TH-TG / ICH-800 2 17 60mm (2.4 ) 708 718 (27.9 28.3) TH-TG-1000 2 17 60mm (2.4 ) 1008 708 (39.7 27.9) TH-CR-270 2 10 40mm (1.6 ) 640 558mm (25.2 22.0 ) * Only for wire shelf. In addition to providing standard accessories, we will manufacture customized accessories to meet your specific requirements. Contact us for details.

Plant Growth Chambers Go to.com Further information on Temperature Chamber products is readily available on our website. 124 GC-1000TLH

Plant Growth Chambers Enough capacity up to 1000L for all your plant growth needs! User-friendly programmable logic microprocessor, streamlined design optimizes air flow and temperature variation. 125 Operating features +5 to 50 (lamp off) / 10 to 50. (lamp on) Max. to 35,000Lux for GC-1000. Max. to 20,000Lux for GC-300 series. 40 to 80% RH for GC-300TLH. (at 20~35 ) 50 to 90% RH for GC-1000TLH. (at 20~35 ) 300 to 5,000ppm CO2 control. (optional) Microprocess PID control / Auto-tuning / Calibration. Digital timer: 1 min to 99 hr 59 min. Over-temperature limiter / Door opening alarm. 10 steps of temperature, humidity, and illumination profiles programmable and repeat up to 999 cycles. (self-testing) Constructional features High quality 304 stainless steel interior and dirtrepellent power coated exterior. User-friendly door system. - Silicone packing for keep inner chamber perfectly. - External door with magnetic sealing for dual airtight. - Smoothly open to minimize damage against test samples. Wide inner tempered glass doors provide a full view of the sample. - A tempered window provides a clear view of your specimen during testing. Powerful air circulator for exclusive air-flow. - Very efficient and spreading type air-flow system for plant growth. - One propeller for GC-1000TLH / A tangent blower and a sirocco fan for GC-300 series. High frequency electronic ballast lamps. - Reinforced Blue and Red spectrums lighting system for plant photosynthesis. - Economical efficiency with stable light and long life span. - Convenient exchange of lamps. Restraint of heat rising. - Unique construction to minimize the heat rising due to a luminous source. - Designed to be exhaust the heat through the upper holes. (only for GC-1000TLH) Easy cleaning of condenser air-filter. - To prevent deterioration of refrigerator, keep filtering dust by periodical filter cleaning. Casters for easy transport and installation. Electronic humidity sensor supports easy calibration and fast reaction. Dual type water level sensor. Adjustable water tank positions. (only for GC-300TLH) Separable shelf and rounded inner chamber corners for easy cleaning. Safety functions Leakage breaker for power supply. Over current protector. Overheat protectors. Switch-off after alarm for over heating. Door opening alarm. Water empty. (TLH models only) Efficient airflow for plant growth Temperature setting graph * 00:00 time value setting for the step 10 makes total number of step is 9 as the above graph.

Plant Growth Chambers 126 Model GC-300TL GC-300TLH GC-1000TLH Chamber volume (L / cu ft) 300 / 10.6 1000 / 35.3 Control system Temperature Illumination Range ( / ) Fluctuation ( / ) at 25 Variation ( / ) at 25 Microprocessor PID controller 5 to 50 / 41 to 122 - Lamp off 10 to 50 / 50 to 122 - Lamp on 20 to 50 / 68 to 122 - with humidity 0.1 / 0.18 - without humidity 0.8 / 1.43 - without humidity Range (Lux) 0 to 20,000 0 to 35,000 Control (steps) 10 11 Lamp Fl lamp (32W 18EA) FL lamp (32W 16EA) Metal lamp (400W 3EA) 40~80 at 20~35 50~90 at 20~35 Range (RH %) - 70~90 at 36~50 60~90 at 36~50 Fluctuation ( RH) at 60% RH - 3 Co2(Optional) Range (ppm) 300 to 5,000 Sensor NDIR CO2 sensor Refrigerant (HP) 1/2 3/4 Temp. heater power (W) 750 2EA 1,500 x 2EA Humid. heater power (W) - 1300 1500 Dimensions (W D H) Interior (mm / inch) 510 540 1100 / 20.0 21.3 43.3 1200 800 1080 / 47.2 31.5 42.5 Exterior (mm / inch) 700 805 1900 / 27.6 30.1 74.8 1410 1070 2150 / 55.5 42.1 84.7 Net weight (kg / lbs) 250 / 551.2 550 / 1212.5 Electrical Requirements (230V) 60Hz / 12.5A 50Hz / 12.5A 60Hz / 16.0A 50Hz / 16.0A 60Hz / 30.0A 50Hz / 30.0A Cat. No. AAHA1011 AAHA1012 AAHA1021 AAHA1022 AAHA1031 AAHA1032 Lamps setting Available to control illumination values with the below lamp setting arrangements GC-300 lamp arrangement GC-1000 lamp arrangement Lamps setting for GC-300 No. Lux (lx) Set values on display Lamp diagram 1 1,500 0000 010 2 2 3,500 0000 101 1,3 3 5,500 0000 111 1,2,3 4 6,000 0101 010 2,4,6 5 8,000 0101 101 1,3,4,6 6 10,000 1010 010 2,5,7 7 12,000 1010 101 1,3,5,7 8 14,000 1111 010 2,4,5,6,7 9 17,000 1111 101 1,3,4,5,6,7 10 20,000 1111 111 1,2,3,4,5,6,7 Above the set values are measured at the center of chamber toward upside. Lamps setting for GC-1000 No. Lux (lx) Set values on display Lamp diagram 1 5,000 0101 000 4,6 (or 5,7) 2 7,500 0000 010 2 3 9,500 1111 000 4,5,6,7 4 12,500 0101 010 2 with 4,6 (or 5,7) 5 15,000 0000 101 1,3 6 18,500 1111 010 2,4,5,6,7 7 21,000 0101 101 1,3 with 4,6 (or 5,7) 8 24,000 0000 111 1,2,3 9 28,000 1111 101 1,3,4,5,6,7 10 31,500 0101 111 1,2,3 with 4,6 (or 5,7) 11 35,000 1111 111 1,2,3,4,5,6,7

Accessories & Options for GC series Ideal for high temperature storage with user-friendly design 127 Wire Shelves Cat. No. Description Included Maximum Dimensions (W L) Models EDA8220 3 15 466 490mm (18.3 19.3 ) GC-300TL GC-300TLH EDA8222 6 30 770 580mm (30.3 22.8 ) GC-1000TLH Perforated Shelves Cat. No. Description Included Maximum Dimensions (W L) Models AAAA1511-15 466 490mm (18.3 19.3 ) GC-300TL GC-300TLH AAAA1512-30 770 580mm (30.3 22.8 ) GC-1000TLH Recorder Models Description Cat. No. All GC series Recorder (6 points) AAA8T500 CO2 Control System Models Description Cat. No. All GC series CO 2 control system AAAA1521 In addition to providing standard accessories, we will manufacture customized accessories to meet your specific requirements. Contact us for details.