C7.1 www.resourceinternational.com 6350 PRESIDENTIAL GATEWAY COLUMBUS, OHIO 43231 PHONE: (614) 823-4949 FAX: (614) 823-4990 RESOURCE INTERNATIONAL INC.
OUTLOT "A" OUTLOT "B" WINCHESTER PIKE WATER LINE PLAN C8.0 RESOURCE INTERNATIONAL INC. www.resourceinternational.com 6350 PRESIDENTIAL GATEWAY COLUMBUS, OHIO 43231 PHONE: (614) 823-4949 FAX: (614) 823-4990
WATER LINE NOTES C8.1 RESOURCE INTERNATIONAL INC. www.resourceinternational.com 6350 PRESIDENTIAL GATEWAY COLUMBUS, OHIO 43231 PHONE: (614) 823-4949 FAX: (614) 823-4990
WATER LINE DETAILS C8.2 www.resourceinternational.com 6350 PRESIDENTIAL GATEWAY COLUMBUS, OHIO 43231 PHONE: (614) 823-4949 FAX: (614) 823-4990 RESOURCE INTERNATIONAL INC.
US-33 RAMP GENDER ROAD OUTLOT "B" OUTLOT "A" COTA PARK AND RIDE WINCHESTER PIKE C9.0 RESOURCE INTERNATIONAL INC. www.resourceinternational.com 6350 PRESIDENTIAL GATEWAY COLUMBUS, OHIO 43231 PHONE: (614) 823-4949 FAX: (614) 823-4990
C9.1 RESOURCE INTERNATIONAL INC. www.resourceinternational.com 6350 PRESIDENTIAL GATEWAY COLUMBUS, OHIO 43231 PHONE: (614) 823-4949 FAX: (614) 823-4990
RICHARD D. FAY 1301301 Richard D. Fay, License #1301301 Expiration 12/31/18 EXISTING TREE OR TREE MASS 2X4 WOOD RAILS 4X4 WOOD POST (OPTIONAL) EXISTING GRADE HIGH VISIBILITY PLASTIC BARRIER FENCING OR SNOW FENCING (PREFERRED) FENCING SHOULD EXTEND TO THE DRIP LINE OF THE TREE. STEEL FENCE; STAKE AT 5' O.C. TREE REMOVAL SUMMARY : 2 TREES REMOVED; 80" SOURCE OF TREE SURVEY AND DATA: RESOURCE INTERNATIONAL INC. TREE REMOVAL NOTES 1. REFER TO CIVIL ENGINEER FOR CLEARING AND GRUBBING. STORAGE OF MATERIALS OR CONSTRUCTION TRAFFIC IS PROHIBITED OUTLOT "B" 1 TREE PROTECTION FENCE SCALE: 1/4" = 1'-0" TREE PROTECTION FENCE; SEE DTL. 1/ L1.00 764 COTA TREE SURVEY Scale: 1" = 40'-0" 0' 20' 40' 80' Tree Replacement Plan L1.00
RICHARD D. FAY 1301301 P L A N T L I S T QUANTITY KEY BOTANICAL NAME COMMON NAME SIZE COND. REMARKS P L A N T K EY Richard D. Fay, License #1301301 Expiration 12/31/18 SHADE TREES 6 NY-SY Nyssa sylvatica Black Gum 2.5" Cal. B&B 5 QU-AC Quercus acutissima Sawtooth Oak 2.5" Cal. B&B SHRUBS 30 TO-SM Thuja occidentalis 'Smaragd' Emerald Arborvitae 6' Hgt. B&B ALL PLANT MATERIAL SHALL MEET THE STANDARDS OF ANSI Z60.1 AMERICAN STANDARD FOR NURSERY STOCK. SEE L1.02 FOR GENERAL NOTES, PLANTING NOTES, AND LANDSCAPE REQUIREMENTS SEE L4.01 FOR PLANTING DETAILS. Shade Tree Evergreen Shrub OUTLOT "B" 764 EXISTING HEDGE TO REMAIN 30'-0"O.C. OUTLOT "A" COTA M LANDSCAPE Scale: 1" = 40'-0" PLAN 0' 20' 40' 80' Trillium Ave. Landscape Plan L1.01
1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO THE CONSTRUCTION MANAGER PRIOR TO COMMENCING WORK. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR BEING FAMILIAR WITH ALL DOCUMENTED UNDERGROUND UTILITIES, PIPES AND STRUCTURES. CONTRACTOR SHALL TAKE SOLE RESPONSIBILITY FOR ANY COST INCURRED DUE TO DAMAGE OF SAID UTILITIES. 3. CONTRACTOR SHALL NOT WILLFULLY PROCEED WITH CONSTRUCTION AS DESIGNED WHEN IT IS OBVIOUS THAT UNKNOWN OBSTRUCTIONS AND/OR GRADE DIFFERENCES EXIST THAT MAY NOT HAVE BEEN KNOWN DURING DESIGN. SUCH CONDITIONS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE AUTHORIZED CONSTRUCTION MANAGER. THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ALL NECESSARY REVISIONS DUE TO FAILURE TO GIVE SUCH NOTIFICATION. 4. CONTRACTOR SHALL NOTIFY OWNER'S REPRESENTATIVE 48 HOURS PRIOR TO COMMENCEMENT OF WORK IN ORDER TO COORDINATE PROJECT OBSERVATION SCHEDULES. 5. ALL WORK TO BE PERFORMED BY LICENSED CONTRACTORS AND EXPERIENCED WORKERS. 6. ALL DIMENSIONS ON THIS DRAWING ARE IN FEET AND INCHES UNLESS OTHERWISE NOTED. 7. DO NOT SCALE DRAWINGS. UTILIZE DIMENSIONS INDICATED ON THE PLANS. THE CONTRACTOR SHALL COORDINATE ALL WORK AND BE RESPONSIBLE FOR ALL METHODS, MEANS, SEQUENCE, AND PROCEDURES OF THE WORK. 8. THE LIMIT OF WORK LINE SHOWN DEFINES THE LIMITS OF WORK IN THIS CONTRACT. THERE MAY BE INSTANCES WHERE EROSION PROTECTION DEVICES, UTILITY SYSTEMS, AND GRADING OPERATIONS EXTEND BEYOND THE PROJECT LIMITS LINE IN ORDER TO SUCCESSFULLY COMPLETE OPERATIONS AND/OR TIE INTO ADJACENT SYSTEMS. REFER TO CIVIL ENGINEER DRAWINGS FOR ANY REFERENCES OR COORDINATION. 9. CONTRACTOR SHALL REPAIR AT HIS OWN EXPENSE, ANY DAMAGE, WHETHER INSIDE OR OUTSIDE OF THE PROJECT LIMITS, TO UTILITY SYSTEMS, SURFACE PAVEMENTS, FIXTURES OR STRUCTURES THAT ARE NOT SPECIFICALLY INDICATED TO BE REMOVED OR OCATED AS PART OF THE PROJECT CONSTRUCTION. IN THE EVENT THAT ANY EXISTING DRAINAGE STRUCTURES OR UTILITIES ARE DAMAGED AND THE SERVICES DISRUPTED, THE LINES SHALL BE IMMEDIATELY REPAIRED AND THE SERVICES RESTORED AS DIRECTED BY THE ARCHITECT AND/OR ENGINEER AT NO COST TO THE BUILDING OWNER. 10. LOCATE AND PROTECT ALL EXISTING UTILITIES DURING CONSTRUCTION UNLESS OTHERWISE NOTED. CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGES TO EXISTING UTILITIES RESULTING FROM CONSTRUCTION ACTIVITIES. CONTACT OHIO UTILITIES PROTECTION SERVICE AT 1-800-362-2764 PRIOR TO EXCAVATION. 11. IN THE EVENT THAT DISCREPANCIES ARISE BETWEEN WHAT IS SHOWN ON THE DRAWINGS AND ACTUAL FIELD CONDITIONS THE CONSTRUCTION MANAGER SHALL BE NOTIFIED IMMEDIATELY FOR RESOLUTION. 1. STAKE ALL BED LINES AND TREE LOCATIONS FOR THE LANDSCAPE ARCHITECT'S REVIEW PRIOR TO INSTALLATION. ALL PLANTING PROCEDURES ARE SUBJECT TO THE REVIEW OF THE LANDSCAPE ARCHITECT AND THE CONTRACTOR SHALL CORRECT ANY DEFICIENCIES FOUND AT NO ADDITIONAL COST TO THE OWNER. 2. SECURE PLANT MATERIAL AS SPECIFIED ON PLANS. IN THE EVENT THAT PLANT MATERIALS SPECIFIED ARE NOT AVAILABLE, CONTACT LANDSCAPE ARCHITECT FOR APPROVED SUBSTITUTIONS. NO SUBSTITUTIONS FOR PLANT MATERIALS WILL BE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL BY THE LANDSCAPE ARCHITECT. 3. VERIFY THAT ALL PLANTING PRODUCTS, PLANT MATERIAL, AND PLANT QUANTITIES DELIVERED TO THE SITE MATCH WHAT IS INDICATED ON THE PLANS AND SPECIFICATIONS. 4. PROTECT ALL PLANT MATERIAL DURING DELIVERY TO PREVENT DAMAGE TO ROOT BALLS, TRUNKS, BRANCHES AND THE DESICCATION OF LEAVES. PROTECT ALL PLANT MATERIAL DURING SHIPPING WITH SHADE CLOTH OR SHIP WITH ENCLOSED TRANSPORT. MAINTAIN PROTECTIONS AND HEALTH OF PLANT MATERIAL STORED ON SITE. HANDLE ALL TREES WITH NYLON STRAPS. NO CHAINS OR CABLES WILL BE ALLOWED. REMOVE UNACCEPTABLE PLANT MATERIAL IMMEDIATELY FROM THE SITE. 5. ALL PLANT MATERIAL SHALL BE NURSERY GROWN, WELL FORMED, TRUE TO SPECIES, HARDENED OFF WITH VIGOROUS ROOT SYSTEMS, FULL CROWN AND CANOPIES, AND FREE FROM DISEASE, PESTS AND INSECTS, AND DEFECTS SUCH AS KNOTS, SUN SCALD, WINDBURN, LEAF DIS-COLORATION, IRREGULAR BRANCHING OR INJURIES. 6. ALL ROOT BALLS SIZES, CONTAINER SIZES, PLANT SIZES, AND TYPES SHALL CONFORM TO THE STANDARDS SET FORTH IN ANSI Z-60.1 2014 'AMERICAN STANDARDS FOR NURSERY STOCK'. 7. ALL PLANT MATERIAL DELIVERED TO THE SITE IS SUBJECT TO THE REVIEW OF THE LANDSCAPE ARCHITECT BEFORE, DURING AND AFTER INSTALLATION. 8. PROVIDE PLANT SAMPLES OR PHOTOGRAPHS OF EACH PLANT SPECIFIED TO THE LANDSCAPE ARCHITECT FOR COMPLIANCE REVIEW PRIOR TO INSTALLATION. 9. TEST FILL ALL TREE AND PLANTING PITS WITH WATER, PRIOR TO PLANTING, TO ASSURE PROPER SOIL PERCOLATION. PITS WHICH DO NOT ADEQUATELY DRAIN SHALL BE FURTHER EXCAVATED TO A DEPTH SUFFICIENT FOR DRAINAGE TO OCCUR AND/OR BACKFILLED WITH SUITABLE DRAINAGE GRAVEL. NO ALLOWANCES SHALL BE MADE FOR PLANT MATERIAL LOSS DUE TO IMPROPER DRAINAGE. CONTRACTOR SHALL REPLACE LOST PLANT MATERIAL WITH SAME SIZE AND SPECIES AT NO ADDITIONAL COST TO OWNER. 10. ALL PLANT MATERIALS, INCLUDING OCATED PLANT MATERIAL, SHALL BE PLANTED IN A PROFESSIONAL MANNER TYPICAL TO THE INDUSTRY STANDARDS OF THE AREA TO ASSURE COMPLETE SURVIVABILITY OF ALL INSTALLED PLANT MATERIALS AS WELL AS TO PROVIDE AN AESTHETICALLY APPROVED PROJECT. CONTRACTOR SHALL REFER TO THE PLANTING DETAILS FOR MINIMUM SIZE AND WIDTH OF PLANTING PITS AND BEDS, GUYING AND STAKING, MULCHING, AND OTHER PLANTING REQUIREMENTS. 11. NO PLANTS SHALL BE PLANTED WITH IN A 2'-0" RADIUS (CLEARANCE ZONE) AROUND ALL ATRIUM DRAINS LOCATED IN LANDSCAPE BEDS. CONTRACTOR SHALL MULCH AREA AROUND ALL ATRIUM DRAINS LOCATED IN LANDSCAPE BEDS. REFER TO ENGINEERING DRAWINGS FOR ALL DRAIN LOCATIONS. RICHARD D. FAY 1301301 Richard D. Fay, License #1301301 Expiration 12/31/18 12. LAWN AREAS TO PROVIDE A SMOOTH AND CONTINUAL GRADE. 13. PLANTING BEDS SHALL HAVE A MINIMUM OF 3" DEPTH, SHREDDED HARDWOOD MULCH. 14. ALL PLANTING AREAS SHALL BE WEED FREE PRIOR TO PLANTING INSTALLATION. 15. REMOVE ALL PLANTING AND LANDSCAPE DEBRIS FROM THE PROJECT SITE AND SWEEP AND WASH CLEAN ALL PAVED AND FINISHED SURFACES AFFECTED BY THE LANDSCAPE INSTALLATION. 16. REFER TO GENERAL NOTES FOR ADDITIONAL INSTRUCTIONS. Landscape Notes L1.02
RICHARD D. FAY 1301301 OUTLOT "B" Richard D. Fay, License #1301301 Expiration 12/31/18 764 1. DO NOT FILL OVER EXISTING TREE ROOT ZONES. 2. TOPSOIL STRIPPED FROM SITE AND REDISTRIBUTED MUST BE CLEANED & AMENDED TO MEET THE DEFINITION OF TOPSOIL IN THE SPECIFICATIONS & TESTED TO PROVE COMPLIANCE WITH THE SPECIFICATION BEFORE THE SOIL WILL BE ACCEPTED FOR REDISTRIBUTION. 3. PREPARE TRANSITION ZONE ABOVE SUBSOIL IN TURF BED AND TREE PLANTING AREAS AS DESCRIBED IN THE SPECIFICATIONS AND SHOWN IN THE DETAILS. COTA 4. ALL AREAS WITHIN GRADING LIMITS OR DISTURBED BY CONSTRUCTION ACTIVITIES AND NOT SHOWN TO RECEIVE IMPORTED SOIL ON THIS PLAN SHALL RECEIVE CLEAN AMENDED TOPSOIL AND BE SEEDED PER THE SPECIFICATIONS. OUTLOT "A" M 5. TOPSOIL DEPTH INDICATED IS THE FINAL DEPTH REQUIRED. COMPENSATE FOR SETTLING AND COMPACTION AS NECESSARY. 6. OVER EXCAVATE AS NECESSARY TO PROVIDE REQUIRED DEPTH OF SOIL. 7. REFER TO THE SPECIFICATIONS FOR MORE INFORMATION ON SOIL AMENDMENTS AND SOIL MIXES. SOILS PLAN Scale: 1" = 40'-0" 0' 20' 40' 80' 8. REFER CIVIL DRAWINGS FOR EXISTING SURVEY INFORMATION. TYPE 1 - SEE DETAIL 1, SHEET L4.01 TYPE 2 - SEE DETAIL 2, SHEET L4.01 TYPE 3 -, SEE DETAIL 3, SHEET L4.01 Soils Plan L3.01
3" LAWN AMENDED SOIL RICHARD D. FAY 2" NOTE: CONTRACTOR TO ORDER SOIL ANALYSIS AND AMEND SOIL FOR PLANTING PER ANALYSIS RECOMMENDATIONS FOR SPECIFIED PLANTING TYPES. AMENDED-IN-PLACE EXISTING SOIL: 2" DEPTH AMENDED SOIL INCORPORATED INTO EXISTING SUBGRADE, SLOPE TO DRAIN. EXISTING SUBGRADE 1301301 Richard D. Fay, License #1301301 Expiration 12/31/18 1 24" 3" TYPE 1 WITH TURF GRASS SCALE: 1 1/2" = 1'-0" 12" MIN PLACE PLANTS PERPENDICULAR TO GRADE DO NOT FILL SOIL OVER TOP OF ROOT BALL MULCH, SHREDDED HARDWOOD SOIL BERM TO HOLD WATER. PROVIDE CUT EDGE FOR MULCH WHEN ADJACENT TO PAVEMENT AND TURF. PULL MULCH AWAY FROM SHRUB. FINISHED GRADE 24" SETTLED TOPSOIL MIX OR AMENDED EXISTING SOIL AS SPECIFIED, AND WHERE NOTED ON PLAN. ROLL BACK AND CUT AWAY BURLAP AND TWINE DOWN THE SIDE. UNDISTURBED OR COMPACTED AMENDED SOIL (AT FILL LOCATIONS) NOTE: CONTRACTOR TO ORDER SOIL ANALYSIS AND AMEND SOIL FOR PLANTING PER ANALYSIS RECOMMENDATIONS FOR SPECIFIED PLANTING TYPES. 120 2 TYPE 2 AND SHRUB / ORNAMENTAL GRASS PLANTING SCALE: 1" = 1'-0" 120 120 STAKING PLAN NOTES: 24" OR DEPTH OF ROOTBALL, WHICHEVER IS GREATER NOTE: CONTRACTOR TO ORDER SOIL ANALYSIS AND AMEND SOIL FOR PLANTING PER ANALYSIS RECOMMENDATIONS FOR SPECIFIED PLANTING TYPES. 3 TYPE 3 AND TREE PLANTING BED SCALE: 1" = 1'-0" FINISH GRADE, MATERIAL VARIES, SEE PLAN. CLEAN CUT EDGE OF LAWN. TREE TRUNK MULCH OR TURF PER PLAN AMENDED SOIL INCORPORATE AMENDED SOIL IN TO 3" OF NATIVE SOIL EXISTING SUBGRADE 1. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION. 2. FINAL TREE STAKING PLACEMENT TO BE APPROVED BY OWNER. 3. DO NOT HEAVILY PRUNE THE TREE AT PLANTING. PRUNE ONLY CROSSOVER LIMBS, CO-DOMINANT LEADERS, AND BROKEN OR DEAD BRANCHES. SOME INTERIOR TWIGS AND LATERAL BRANCHES MAY BE PRUNED, HOWEVER, DO NOT REMOVE THE TERMINAL BUDS OF BRANCHES THAT EXTEND TO THE EDGE OF THE CROWN. 4. MARK THE NORTH SIDE OF THE TREE IN THE NURSERY, AND ROTATE TREE TO FACE NORTH AT THE SITE WHEN EVER POSSIBLE. 5. IF PLANT IS SHIPPED WITH A WIRE BASKET AROUND THE ROOT BALL, CUT THE WIRE BASKET IN FOUR PLACES AND FOLD DOWN (8 IN.) INTO PLANTING HOLE. 6. REMOVE ALL TWINE, ROPE, WIRE AND BURLAP FROM TOP HALF OF ROOTBALL. 7. SET TREE PLUMB IN PLANTING PIT. 8. EACH TREE MUST BE PLANTED SUCH THAT THE TRUNK FLARE IS VISIBLE AT THE TOP OF THE ROOT BALL. TREES WHERE THE TRUNK FLARE IS NOT VISIBLE SHALL BE REJECTED. DO NOT COVER THE TOP OF THE ROOT BALL WITH SOIL. 5 TREE PLANTING SCALE: N.T.S. ARBOR TIE THREE 2"X4" PRESSURE TREATED PINE STAKES, SPACE EVENLY AROUND TREE. TOP-OF-STAKE SHALL BE NOT LESS THAN 2/3 DISTANCE FROM GROUND TO LOWEST BRANCH. DRIVE STAKES 18" MIN. BELOW BOTTOM OF PIT TREE BLADDER 3" MULCH, SHREDDED HARDWOOD AMENDED SOIL REMOVE 50% OF WIRE BASKETS, 50% BURLAP, AND 100% TWINE ON ROOT BALL. INCORPORATE AMENDED SOIL IN TO 3" OF NATIVE SOIL TAMP SOIL AROUND ROOT BALL BASE FIRMLY WITH FOOT PRESSURE SO THAT ROOT BALL DOES NOT SHIFT. 4 TYPICAL BED PLANTING SCALE: 1" = 1'-0" Site Details L4.01
STREET LIGHTING NOTES 1. GENERAL 2. POWER SERVICE 3. ITEM 1000 PAD MOUNTED CONTROL SITE, 480V, AS PER PLAN 4. ITEM 1000 POLE ALUMINUM WITH T-BASE FOR TEAR DROP LUMINAIRE, AS PER PLAN 5. ITEM 1000 LUMINAIRE 250W HPS, 480V, TEAR DROP, AS PER PLAN 6. FURNISHING SPARE PARTS 7. LIGHT POLE FOUNDATION 8. PAINT CHIP SUBMITTAL 9. CONDUIT 2" UNDER STREET PAVEMENT, AS PER PLAN 10. CONDUIT 2" IN OPEN AREAS, AS PER PLAN 11. ITEM 1000 CIRCUIT CABLE, STREET LIGHT CIRCUIT, THREE #4AWG, 5KV, AS PER PLAN CANAL WINCHESTER - LIGHTING, PLAN INSERT SHEET 31' POLE WITH 250W HPS LUMINAIRE (MIS-129, AS PER PLAN) 480 VOLT, THREE-WIRE, GROUNDED NEUTRAL STREET LIGHT CIRCUIT, 3 #4 AWG, 5KV TYPICAL LIGHT POLE AND FOUNDATION LOCATION STREETLIGHT TYPE "A" LIGHTING NOTES AND DETAILS LIGHTING PLAN INSERT SHEET ES1.0 TRANSYSTEMS www.transystems.com 02-01-2017 HJF 1105 SCHROCK ROAD HJF COLUMBUS, OHIO 43229 HJF PHONE: (614) 433-7800 FAX: (614) 846-2602 06-09-2017 07-19-2017 08-11-2017 09-12-2017 HJF HJF
LIGHTING GENERAL NOTES IN ADDITION TO THE ODOT CONSTRUCTION AND MATERIAL SPECIFICATIONS, THE CITY OF COLUMBUS, OHIO, CONSTRUCTION AND MATERIAL SPECIFICATIONS AND THE COLUMBUS DIVISION OF POWER AND WATER MATERIAL AND INSTALLATION SPECIFICATIONS (MIS) ARE HERBY INCORPORATED INTO THIS SET OF PLANS. THE DIVISION OF POWER AND WATER STANDARD SPECIFICATIONS CAN BE OBTAINED AT 3500 INDIANOLA AVE. THE MIS NUMBERS LISTED IN THE LIGHTING QUANTITIES ARE REFERENCED TO SPECIFIC SPECIFICATIONS PUBLISHED BY THE DIVISION OF POWER AND WATER WHICH SHALL GOVERN ALL WORK ATING TO THE INSTALLATION OF ROADWAY LIGHTING EQUIPMENT AND APPARATUS FOR THIS PROJECT. GENERAL THE STREET LIGHT INSTALLATIONS SHALL CONFORM TO THE CITY OF COLUMBUS STREET LIGHTING MATERIAL AND INSTALLATION SPECIFICATIONS (MIS) SUPPLEMENTED BY THE CITY OF COLUMBUS 2012 CONSTRUCTION AND MATERIALS SPECIFICATIONS (CMS), NOVEMBER 1, 2016 REVISION. TRANSYSTEMS 1105 SCHROCK ROAD COLUMBUS, OHIO 43229 PHONE: (614) 433-7800 FAX: (614) 846-2602 www.transystems.com 02-01-2017 HJF HJF HJF HJF HJF 06-09-2017 07-19-2017 08-11-2017 09-12-2017 LIGHTING NOTES ES2.0
GENERAL SUMMARY - TRILLIUM ROADWAY LIGHTING (PUBLIC) NOTE: ESTIMATED QUANTITIES AS SHOWN ON THE CONSTRUCTION DRAWINGS ARE APPROXIMATE ONLY. THE ESTIMATED QUANTITIES ARE BELIEVED TO BE COMPLETE AND ACCURATE, HOWEVER, THE CONTRACTOR IS RESPONSIBLE TO COMPLETE THE PROJECT AS TO THE INTENT SHOWN ON THE DRAWINGS AND DESCRIBED IN THE SPECIFICATIONS AND CONTRACT DOCUMENTS. ADDITIONAL COMPENSATION WILL NOT BE MADE TO THE CONTRACTOR FOR HIS FAILURE TO INCLUDE THE TOTAL COST OF ALL LABOR, EQUIPMENT, AND MATERIALS IN THE TOTAL BID PRICE. LIGHTING SUMMARY ES3.0 TRANSYSTEMS 1105 SCHROCK ROAD COLUMBUS, OHIO 43229 PHONE: (614) 433-7800 FAX: (614) 846-2602 www.transystems.com HJF HJF HJF HJF HJF
4 14 GENERAL NOTES: A. SEE ES1.0 FOR ROADWAY LIGHTING DETAILS. B. ROADWAY POWER SHALL BE OBTAINED FROM EXISTING GENDER ROAD CIRCUIT. 3 6 6 7 2 STA 2+2.77, 16.5' LT 5 1 7 3 6 4 6 (P-1) 8 7 STA 3+85.36, 16.5' RT 7 10 7 (P-2) 6 C L 8 6 7 6 7 6 10 STA 5+37.14, 16.5' LT (P-3) 8 STA 6+66.05, 24.18' RT 9 (P-4) PS PS 10 11 WINCHESTER PIKE TRANSYSTEMS HJF HJF HJF 1105 SCHROCK ROAD COLUMBUS, OHIO 43229 PHONE: (614) 433-7800 FAX: (614) 846-2602 HJF HJF www.transystems.com M CODED NOTES: 1. REMOVE AND OCATE EXISTING LIGHT POLE FROM APPROX. 0+46.46, 26.50' RT TO STA 2+2.77, 16.5' LT. REMOVE EXISTING FOUNDATION. 2. OCATED EXISTING LIGHT POLE ON NEW FOUNDATION, PROVIDE NEW ANCHOR BOLTS STA 2+2.77, 16.5' LT. 3. INSTALL NEW PULL BOX OVER EXISTING CONDUIT 4. DISCONNECT CIRCUIT, REMOVE EXISTING CABLES, CLEAN CONDUIT AND RUN NEW CABLE TO EX. LIGHT POLE (APPROX.105' NORTH OR 173' SOUTH) 5. 3" CONDUIT, 725.04 UNDER PAVEMENT 6. MIS-004 PULL BOX MEDIUM DUTY, 13" X 24" 7. MIS-015-2" CONDUIT IN OPEN AREAS 8. MIS-017-2" CONDUIT UNDER PAVEMENT 9. MIS-016-2" CONDUIT UNDER CONCRETE SIDEWALK 10. PROPOSED ROADWAY LIGHT POLE. 11. CONDUIT STUB 12. ENTRANCE SIGN 13. REMOVE CONDUIT AND WIRING TO SOURCE PS 13 LEGEND EX UTILITY POLE/ LIGHT POLE PROP LIGHT POLE - 105W LED PROP LIGHT POLE (TWIN) - 105W LED PROP STREET LIGHT POLE PROP PULL BOX PS 14. REMOVE PEDESTAL AND WIRING BY TELEPHONE COMPANY PROP LIGHTING CONDUIT PROP CONTROL CENTER LIGHTING PLAN ES4.0