PROGRAMMING INSTRUCTIONS

Similar documents
Model SPA-516 HOT TUB OPERATING INSTRUCTION

Model SPA-308 HOT TUB OPERATING INSTRUCTION

Model SPA-8138 HOT TUB OPERATING INSTRUCTION

USER MANUAL OF KL8300 SYSTEM

HOT TUB. Model SPA-313. Serial No: POPERATING INSTRUCTION

beyond 260VAC, then LED shows. In these two kinds of situation, the system will not go into normal operation.

User manual Whirlpool

SG User Manual

Massage Bathtub. Instructions of Installation and Use. Preparations MT-RT1804. Cleaning & Maintaining

Preparations MT-RT1806. Cleaning & Maintenance. Precautions

WINE COOLER INSTRUCTION MANUAL

I. U881 Series Structure...1 II. Security Advice...2 III. Technical Parameter...3 IV. Install U881 Sauna Room V. Electricity Supply And Water

Wine Cooler. Instruction Manual PWC-24ZWX

Installation Instruction of AM168 TS-series Control panel

Installation Instruction of AM124ETL-L TS-series Control panel

15,000 BTU Portable Air Conditioner

No advanced advice will be submit before we change our design and size. The pictures may be a little different from the real products.

99 F PREHEAT. C d. Topside Controls for Spas with Three Pumps

ARLEC. User Instructions

Aquapeutics STEAM ROOM. Installation Manual WG-U6811. Make the most of your shower;make the best for your home!

Europa Shower Cabinet

Ozone Waterfall Foot and Leg Spa Bath Massager

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

No advanced advice will be submit before we change our design and size. The pictures may be a little different from the real products.

Contents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4

Important safety instructions

YS-B501 SPA Deluxe Overall Functional Capsule

LEVENS STEAM SHOWER ENCLOSURE

EL/GL Series - Mach 3 ML550 User Guide

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

INSTALLATION AND USER MANUAL

Unity 180 Premium Whirlpool 180/80/62 cm

Instruction manual. Aluminium radiator with ceramic heart. Smart Electric Heaters

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

INDUCTION COOKER MODEL: EIC-G1810(BK) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

FREWIN STEAM SHOWER ENCLOSURE

ARLEY STEAM SHOWER ENCLOSURE

QUICK 3202 OPERATION MANUAL. Lead Free Soldering Station

DIGIHEAT IN LINE HEATERS

Instruction Manual. Please read this manual carefully before operating this unit.

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

EL/GL Series - Mach 3 MLM990S User Guide

: PRT / PRT PRT / PRT-N1

INSTALLATION MANUAL & OPERATING INSTRUCTIONS

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

155mm. 820mm. 540mm E D. 940mm. 600mm

MANUAL INTELLIVENT CELSIUS

ML550, 551, 554 Panel Operation

EL/GL Series - Mach 3 ML900 User Guide

Installation and Operation Manual

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

Whirlpool Tub USER S MANUAL

Spas with 2 or 3 Pumps

Instruction Manual for Electric Ovens OO757X OO986X

OPERATOR S MODEL HHC-901 HHC-904 HEATED HOLDING CABINET REGISTER WARRANTY ONLINE AT

DIGITAL QUARTZ INFRARED HEATER. Model No.: SPP1500SBH

Installation Manual SPA BROADWAY MAXI

Massage Bathtub. Instructions of installation and usage. Instructions of Installation and Use TLP-632. Cleaning&Maintenance

USER MANUAL

Model: Slimline-N. 1 Slimline Series

SILK CERAMIC STRAIGHTENER

Part 8 PROBLEMS AND SOLUTIONS

2000W Ceramic Wall Heater with LED Display

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

Installation and Operating Manual

OWNER S MANUAL. Evaporative Cooler. (English) (EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY

MULTISPLIT DUCT H3M Installation and user's manual

Installation and user s manual Read carefully and keep it for later reference

Induction Cooker. Instruction manual. Model CM352-A

ROBOTIC POOL CLEANER Raptor SE HJ2032 USER MANUAL

GSM Smart Home Alarm Apparatus. [99+4 defense zones] Instruction for Use

M-K STEAM ROOM

5KEK1222A W A_v05.indd 1 7/10/15 1:20 PM

GLASS HEATER OWNER S MANUAL. Model No. GH-15A

INFRARED PANEL HEATER

Multi-Temp Jug Kettle CPK17U

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual

Congratulations! You've just purchased a new Marey ECO tankless water heater and will soon begin to enjoy the benefits of going tankless.

PDA20DX Air Purifying Dehumdifier Manual

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

Model : PRT-EN Model: PRT-EN1

INSTRUCTION MANUAL. Blue Whale Spa Ltd, 11 Glaisdale Drive East Nottingham, NG8 4GU

Wired Controller XK60

TO BE REMOVED FOR USE BY THE OCCUPANT.

Motion Sensor Oscillating Heater with Digital Control

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

Model: Slimline-B. Battery Series

AURATON 2005 / 2005 TX

26 FIREBOX EN RU UA FR

EVAPORATIVE AIR COOLER SERVICE MANUAL

Limited Edition Music Heater

Soaking, Airmasseur & MicroSilk Baths

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Parts introduction FRONT BACK

ST E /ST E / ST E / ST E ST E / ST E / ST E

Packing list. Packing 1. Packing 2. Packing 3. Spare parts list

Underfloor Heating Programmable Thermostat

INSTRUCTION MANUAL. Blue Whale Spa Ltd, 11 Glaisdale Drive East Nottingham, NG8 4GU

Complete Shower Room Installation Guide and Operation Manual. Models 8727 / 8728

Transcription:

1. Illustration to buttons PROGRG INSTRUCTIONS SET TEMP OZONE LOCKED PM SET F ONOFF HEAT OZONE OPEN CLOSE MEM LIGHT CD BLOWER PUMP1 PUMP2 PUMP3 ON/OFF PUMP3 PUMP2 HEAT F/ C Fig. 1:Sketch map of big massage bathtub Radio channel up / Minute ON/OFF power On/ Off or mode shift RADIO radio channel down/ Hour CD SET radio on/ off or CD shift volume up/ time setting shift F/ C blower on/ off or & Shift OPEN volume down/ open memory channel LED & fiber optic lights on/ off MEM radio channel memory/ lock channel whirlpool pump 1&2 on/ off CLOSE select radio channel / close channel PUMP2 waterfall & column pump on/ off OZONE ozonizer on/off PUMP3 whirlpool pump 3 & circulation pump on/ off. HEAT preheat on/ off or preset TEMP Temperature setting Note: 1. All the functions listed on the key in blue letter only works on the off model. 2. PUMP2 function is not available on SPA-329,312, which model without water column and waterfall. 1

2. Functions Summary (1) Constant heating, preheating, displaying and setting water temperature. (2) Display time in & PM 12 hours mode. (3) Circulation cleaning and presetting circulation cleaning. (4) Radio, 10 channels memory or circumscribe device of CD or DVD, offering power output for DVD/CD and TV set. (5) Display and adjust 87 grade volume. (6) Infrared remote control. (7) Underwater multicolor LED light and ozone. (8) Freezing-proof protection. (9) Functions memory when power shut down suddenly (10)Fahrenheit & Celsius temperature display shift. (11) Three whirlpool pumps,one circulation pump, One water Column & waterfall pump, One blower. (12) Functions locked on panel. (13) Limit working watts control (optional) (14) Selection of 110-120V/60Hz, 220-240V/50-60Hz, or 380-415/50Hz 3. Operations 1) When the spa is connect with power, the control panel will be in dark light, and LCD screen on the panel will be displaying time and current water temperature, and the radio channel will be display ---. Under the situation, it indicates the spa system is on off status, the preheat and circulation cleaning functions are turned off. If the water temperature sensor is broken circuit, the screen will display E1, if the water temperature sensor is short circuit, the screen will display FF. In this case, the heater can not work normally, please check the wire of which is connecting with the water temperature sensor. Fig. 3:normal water temperature. Fig. 4:water temperature sensor broken circuit 2) Lock operation : This is a manual and automatic function. If there is no any operation on the panel in 30 minutes, all the current working functions will be locked automation. MEM On the off status, press the the key to lock any functions, and the screen will display the locked MEM signal. To press the key twice to unlock the functions,once the function is unlocked, the locked signal will disappear on the screen. 3) Time setting operation: 2

On the off status and the preheat and circulation cleaning without working, press key to start time setting. The : signal will stop to flash, but the minute and hour will flash at this time or key one time,will add one hour, the hour number will be displaying on the screen. Pressing the without stop, the hours will increase continually till stop pressing the key. The hours adjustment range is 0~PM 11. key one time,will add one minute, the minute number will be displaying on the screen. Pressing the without stop, the minutes will increase continually till stop pressing the key. The minutes adjustment range is 0-59. After finishing the time setting, the system will quit out the time setting mode in 6 seconds. 4) Operation to circulation-cleaning setting: Only one circulation-cleaning program can be set in one day in a spa. The circulation cleaning working status will be displaying on the LCD screen. When it works or can not see from the screen. If the signal is displaying on the screen, it indicates the circulation-cleaning is on, and the indicates the circulation cleaning is off. See following Fig. 5-6. signal is disappeared, it Fig. 5: Circulation-cleaning off Fig. 6:Circulation-cleaning on All the setting steps of circulation-cleaning must be operated on the off status, the LCD screen will be displaying --- at this status. (1) Press PUMP3, to enter the Circulation-cleaning setting model, and the screen will flash the signal. OPEN (2) Press,can start the circulation-cleaning setting (If press CLOSE key, or without any pressing in 6 seconds,the circulation-cleaning will be shut down, and the system will quit out the setting model automatically.), And this time, signal won t flash The system enter into the setting mode for the start time of circulation-cleaning setting, the screen will flash a time number (this time is the start time of the circulation-cleaning.), at this moment,press the and key to set the time. 3

key one time,will add one hour, the hour number will be displaying on the screen. Pressing the without stop, the hours will increase continually till stop pressing the key. The hours adjustment range is 0~PM 11. key one time,will add one minute, the minute number will be displaying on the screen. Pressing the without stop, the minutes will increase continually till stop pressing the key. The minute adjustment range is 0-59. After seting the start time of Circulation-cleaning,and move on to set the working time of circulation-cleaning. (3) Press SET key to shift to the setting mode of the working time of circulation-cleaning. At this moment, the time displaying on the screen is at least 5 minute., the working time number on the screen won t flash. key one time, the working time will add 5 minute. The maximum working time of circulation time is19 hours 55 minutes(this time can be adjusted according to the user). After setting the working time of Circulation-cleaning,and move on to set the ozone working in synchronization (4) And then press the SET key again to set startup the ozonizer working in synchronization, at this time, the OZONE signal will be flashing on the screen. This flashing signal indicates the ozonizer doesn t work in synchronization. Press the OZONE key to startup the ozonizer, when the ozonizer woks, the OZONE signal will be displaying on the screen. PUMP3 (5) after the steps are done, press the key to confirm the setting, or wait for 6 seconds, the system will confirm the circulation cleaning setting and quit out setting mode. Detailed steps refer to the below Fig. (1) PUMP3 (2) OPEN set: start time of Circulation-cleaning SET (3) set: working time of Circulation-cleaning SET (4) OZONE startup ozonizer in synchronization 4

(5) Press PUMP3 to confirm *** Notice *** (1) the setting steps of Circulation-cleaning must be operated on the off status. (2) During the whole setting process, the circulation pump and ozonizer are not working. 5 Preheating setting: Only one preheating setting program can be set in one day in a spa. The preheating woking status will be displaying on the LCD screen. If it s work or not,can be seen from the screen. If the ON signal is diplaying on the screen, it indicates the preheating is working, and the OFF signal is displaying on the screen, it indicates the preheating is not working. See following Fig. 7-8. ON OFF Fig. 7:Preheating On Fig. 8:Preheating Off All the setting steps must be operated on the off status, the LCD screen will be displaying --- signal at this status. (1) Press HEAT, to enter into the preheating setting model, and the screen will flash the ON/OFF signal. OPEN (2) Press,can start the preheating setting (If press CLOSE key, or without any pressing in 6 seconds,the preheating will be shut down, and the system will quit out the setting model automatically.),the signal on the screen will be from ON/OFF turn into ON, won t flash, just displaying, The system is on the setting mode for the start time of preheating setting, the screen will flash a time number(this time is the start time of the preheating. (Press on the CLOSE key can turn show down preheating setting, and the OFF signal will be displaying on the screen). at this moment,press the and key to set the time. Pressing the key one time,will add one hour, the hour number will be displaying on the screen. without stop, the hours will increase continually till stop pressing the key. The hours 5

adjustment range is 0~PM 11. key one time,will add one minute, the minute number will be displaying on the screen. Pressing the without stop, the minutes will increase continually till stop pressing the key. The minutes adjustment range is 0-59. After setting the start time of preheating,and move on to set the working time of preheating. (3) Press SET key to shift to the setting mode of the working time of preheating. At this moment, the time displaying on the screen is at least 10 minute, the working time number on the screen won t flash. Pressing the key each time, the working time will add 10 minute, Pressing the key each time, the working time will add one hours. The maximum working time of preheating is 19 hours 50 minutes. After setting the working time of preheating,and move on to set water temperature. (4) And then press the SET key to set the water temperature, at this time, the SET signal will be flashing on the screen. Pressing the TEMP key to increase the temperature, loose the key when temperature reach the require degrees. The limited temperature is 18-40. HEAT (5) after all steps are done, press the key to confirm the setting, or wait for 6 seconds, the system will confirm the preheating setting and quit out setting mode. (1) HEAT (2) OPEN set: start time of Preheating SET (3) set: working time of preheating SET (4) TEMP set: temperature degrees (5) Press HEAT to confirm 6

*** Notice *** 1 all the setting steps of preheating must be operated on the off status, and the LCD displays ---. 2 Please note that if the screen shows "on" or "off". If the screen showing "on" signal, indicates preheating function is on., when the time reach to the set time of preheating, the heater will work automatically. If the screen show "off" signal, indicates preheating setting is not successfully, the heater won t start at anytime, please reset the preheating program. 3 During the whole setting process, the circulation pump and heater are not working. 6 Preheating working status: When time reach the set time of preheating program, and the ON signal of preheating is displaying on the screen, meanwhile, the tub is filled with enough water. The preheating program will be startup automation, the heater beginning to heat and the circulation pump will be working at the same time. The screen is showing the countdown of preheating. Once the temperature reach to the setting degrees, the heater will stop heating automatically. Once the temperature is below the setting degrees, the heater will begin to heat automatically. As soon as the countdown time is finished, the preheating program will shut down, and heater stop working automatically. During the preheating process, to press the HEAT key or ON/OFF key to quit out the preheating program, turn off the heater. 7 Circulation-cleaning working status: On the off status, when time reach the set time of circulation-cleaning, and the signal of circulation cleaning is displaying on the screen, meanwhile, the tub is filled with enough water. The circulation-cleaning program will be start-up automatically, the circulation pump and ozonizer will begin to work at the same time. The screen is showing the countdown of circulation-cleaning. The working time of ozonier is: works for 15 minutes and stop for one hour and 45 minutes, and then begin to works for 15 minutes and stop for one hour and 45 minutes. This working status will last till the circulation-cleaning time is finished. As soon as the countdown time of is finished, the circulation-cleaning program will shut down automatically. During the circulation-cleaning process, to press the ON/OFF key to shut down the circulation-cleaning program, the circulation pump will be off automatically. *** Notice *** 1, if the setting temperature is lower than or equal with water temperature in the tub, Even the Preheating program is on, the circulation pump and heater won t be working. 2, For the I type heater, the circulation pump must be or more than 1HP, otherwise there is no enough water pressure in the heater tube to push on the valve of water pressure sensor, so the heater can t start to work.(there is a water pressure sensor in the heater tube). 7

3, If the above conditions are delivered, and the heater is still not working, please draw the wire of water pressure sensor from the heater, then connect two ends of this wire directly, and the heater will works normally. 8 Turn ON/ OFF operation. On the off model, to press the key to turn on, and press the key again to turn off. When all systems was turned off and the screen shows --- signal; when it was turned on, the --- signal will disappear. Like the following Fig. OFF OFF Fig. 9: OFF Fig. 10: ON 9 Temperature setting On the on status, meanwhile, the heater is working, the temperature can be adjusted. To press the TEMP key each time, the temperature will add one degree. Pressing the TEMP key without stop, the degree will increase continually till 45. When the degree is reach 40,to press the TEMP key, the degree will be 18 again. The adjustable temperature degrees is 18-45. 10 Operation of Radio & CD: Fig.11:Radio frequency is 105.2 MHZ,Save the present frequency to channel 3 (Save channel) or Exchange the frequency form channel 3 to the present (Searching channel) AUDIO Ⅰ) Key CD is the ON/OFF key for radio and CD It is only available in the status of power on. The first pressing is turning on the radio,the second pressing will turn off the radio and turn on the CD at the same time, and the third,will turn off the radio and CD simultaneous. PUMP3 Ⅱ) LCD will show present frequency and volume of the radio after turning on the radio Ⅲ) on the working of status, The volume of the present radio frequency can be changed by pressing & Ⅳ) Pressing the key CLOSE will take out the memorized radio frequency,pressing the key 8

CLOSE continually will take out the memorized radio frequency from channels will be saved at present channel by pressing this key continually If none of the channel, LCD will display --- MEM Ⅴ) Press the key could memorize the present radio channel, Pressing the key MEM continually to select the present radio channel from memory The channel of max is 10, situations of channel is 0-9 Ⅵ) The volume can be changed by pressing key SET & OPEN 11 Operation of Pump : The Pump1 key are controlling two whirlpool pumps for massage, the Pump2 key is controlling for the pump for water Column & waterfall. the Pump 3 key is controlling a single whirlpool pump for massage. When press the pump 3 key,the screen is displaying the signal. ( if the screen is displaying the signal, this signal is indicating the circulation pump is working). 12 Operation of Ozone: The ozone could be working on the circulation-cleaning program. Press the key OZONE to turn on/off the ozonizer. After the ozonizer is turned on, it will last working forever till it is turn off. The working situation is working 15 minutes every two hours, in other words, works for 15 minutes and stop for one hour and 45 minutes, and then begin to works for 15 minutes and stop for one hour and 45 minutes. 13 Operation of lights: key to turn on or off the underwater light and fiber optic lights. All the lights can be turned on on any mode, so to turn on is way to test if the spa system is connect with power successfully or not. 14 Operation of constant water temperature: 1), HEAT key two times( the first time is to turn on the circulation pump)to turn on the heater, and press TEMP to set the temperature degrees. The heater will be working, not stop,till the temperature reach the set degrees. Once temperature is below the set degrees, the heater will begin to work again automatically. For example:if the temperature is set at 35, when the water temperature reaches or exceeds 35, the heater will be shut down automatically and the circulation pump will stop too in 5 seconds. However, when the water temperature reach or lower than 34, the heater will start up automatically again to heat the water. In this way, the user can keep the same water at anytime if the spa system is with power. 2) If the water temperature sensor is broken circuit, the screen will display E1, if the water temperature sensor is short circuit, the screen will display FF. In this case, the heater can not work normally, please check the wire of which is connecting with the water temperature sensor. 15 Operation of blower: 9

F/ C 1)To press the key to turn on/off blower. The blower can work without any water in tub. So it s way to test if the spa system connect with power successfully or the controller is working or not? 2) Blower will be shut down automatically after it has been working for 2 hours. 16 Fahrenheit & Celsius temperature shift: On the off mode, to press the F/ C key to shift the Fahrenheit or Celsius degrees. 17 If the water lever in the tub is not reaching the water level sensor, no pumps, no heater, no ozonizer can be turned on, expect the blower. The signals will be flashing on the screen. 18 Frozen preventing control: The heater & circulation pump will be turned on automatically when water temperature is below 5,and will be shut down when the temperature reaches 10. To keep this function on, must ensure the spa is connect with power well. 4.Electric parameters (1) Performance index: Rated voltage:220vac/50hz(110vac/60hz) Voltage-resistance: 1250V/1 minute without penetration Water resistance grade: IPX5 Maximum working current: 60A(100A/110V) Isolative resistance :>=200MΩ Electric shock resistance: first grade (2) Output loading index Heater: AC220V/3KW x 1 Surf Water pump: AC220V/3 HP x 1 water pump:ac220v/2hp x 2 water pump:ac220v/1hp x 1 Air pump: AC220V/0.7kw x 1 spa light: AC12V/5W x 2 Ozone: AC12V/15W x 1 water pump:ac220v/0.35hp x 1 Radio: 1) Frequency Range: FM: 87.0~108.0MHz 2) Maximum Output Power: 10W 3) Speaker:8Ωdamp proof speaker 5. Warning Information a. Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. b. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. c. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. d. Children should be supervised to ensure that they do not play with the appliance. e. Details concerning cleaning and other maintenance f. Maintenance of water purity, especially PH values and chlorine concentrations. g. Cleaning and disinfection h. Use and installation of a cover. i. Disposal of water j. Precautions to avoid damage due to water freezing k. Precautions to avoid damage when the appliance is left empty for extended period. 2.2 Sub-clause 7 10

The installation instruction shall state the substance of the following: - Earthed appliances must be permanently connected to fixed wiring; - The appliance should be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 ma. - The floor has to be capable of supporting the expected load. - An adequate drainage system has to be provided to deal with overflow water. - Details of how to follow the wiring rules, for example, specifying that parts are installed in the correct zone and that equipotential bonding is carried out. WARNING 1 DANGER:RISK OF ELECTRIC SHOCK,Connect only to a circuit protected by a Ground Fault Circuit lnterrupter. 2 Grounding is required. The unit should be installed by a qualified service representative and ground. 3 FOR YOUR SAFETY-This product should be installed by a professional service technician,qualified in hydrotherapy bath installation. 4 lt s prohibited to cover the instrument with something while operating. 5 when using at the first time,be sure there is water in heater pipe before staring. 11

12

13