Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

Similar documents
Product Data. Split System Heat Pump D-EN. February 2016

Product Data. Split System Heat Pump A-EN. March 2016

Product Data. Split System Cooling D-EN. August 2016

Product Data. Split System Cooling H-EN. January 2017

Product Data. Split System Cooling E-EN. November 2016

Product Data. Split System Cooling A. November 2013

Product Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A

Product Data. Split System Heat Pump

Split System Heat Pump Product Data

AMERICAN STANDARD 14 MODELS 4A7B E

Product Data Split System Cooling

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Heat Pump Product Data

Split System Cooling Product Data

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Heat Pump Product & Performance Data

Split System Cooling Product Data

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

Split System Cooling Product & Performance Data

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Split System Heat Pump Product Data

Split System Heat Pump Product Data

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Heat Pump Product Data

Split System Cooling Product Data

Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

Split System Cooling Product & Performance Data

Appendix J Noise Appendix

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

Illusion Split System

Hyperion TM Split Systems

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

Service Facts. Split System Heat Pump 4A6H5019H-SF-1C-EN. August A6H5019H1000A

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Split System Cooling Product Data XB 1000

3-11/ /8 4-5/16 6-5/8 5-7/8 1-9/16. Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compartment panel

Commercial High-Efficiency Condensing Units

MACH N-407 Heat Pump Air-Cooled Chiller

Variable Speed Convertible Air Handler 2 1/2 Ton

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Variable Speed Convertible Air Handler 5 Ton

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Commercial High-Efficiency Condensing Units

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

Split System Heat Pump Product Data

Variable Speed Convertible Air Handler 4 Ton

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

R4H4. Product Specifications

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

MAC N-407 Air-Cooled Chiller

R4H4. Product Specifications

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

2 shp 13 lc 1 36 t - 1 a

WCH5**4. Product Specifications

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG:

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

N4H4. Product Specifications

TruComfort Variable Speed Cooling Single Phase 2-5 Tons

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

4YCC3048A3096A /3/ /

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

PACKAGE AIR CONDITIONER

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

N4A6. Product Specifications

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

Transcription:

Product Data Split System Heat Pump 4A6H6024H1000A Note: Graphics in this document are for representation only. Actual model may differ in appearance. February 2015 12-1202-1B-EN

Product Specifications Model No. (a) 4A6H6024H1000A 4A6H6030H1000A 4A6H6036H1000A POWER CONNS. V/PH/HZ (b) 208/230/1/60 208/230/1/60 208/230/1/60 MIN. BRCH. CIR. AMPACITY 14 17 18 BR. CIR. PROT. RTG. MAX. (AMPS) 25 25 30 COMPRESSOR DURATION - SCROLL DURATION - SCROLL DURATION - SCROLL RL AMPS LR AMPS 10.9 62.9 12.8 67.8 14.1 72.2 Outdoor Fan FL AMPS 0.64 0.64 0.64 Fan HP 1/8 1/8 1/8 Fan Dia (inches) 23 27.5 27.5 Coil SPINE FIN SPINE FIN SPINE FIN Refrigerant R-410A 7 LBS., 5 OZ 8 LBS., 0 OZ 8 LBS., 14 OZ LINE SIZE IN. O.D. GAS (c) 3/4 3/4 3/4 LINE SIZE IN. O.D. LIQ. 3/8 3/8 3/8 Charge Spec. Subcooling 10 F (see charging info) 10 F 10 F Dimensions H x W X D Crated (IN.) 38 x 30.1 x 33 42 x 35.1 x 38.7 42 x 35.1 x 38.7 Weight Shipping (lbs.) 208 245 246 Weight Net (lbs.) 174 198 199 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control NA NA NA Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT023 BAYECMT004 BAYECMT004 Start Kit BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT302 BAYCCHT302 BAYCCHT302 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM107 BAYLOAM107 BAYLOAM107 Refrigerant Lineset (d) TAYREFLN7* TAYREFLN7* TAYREFLN7* Service Valve Panel Cover AAYSVPANL3343AA AAYSVPANL0044AA AAYSVPANL0044AA (a) (b) (c) (d) Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. Standard line lengths 60, Standard lift 60 Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub#32 3312 0* (* denotes latest revision).. * = 15, 20, 25, 30, 40 and 50 foot lineset available. 2 12-1202-1B-EN

Product Specifications Model No. (a) 4A6H6042H1000A 4A6H6048H1000A 4A6H6060H1000A POWER CONNS. V/PH/HZ (b) 280/230/1/60 280/230/1/60 280/230/1/60 MIN. BRCH. CIR. AMPACITY 22 26 31 BR. CIR. PROT. RTG. MAX. (AMPS) 35 40 50 COMPRESSOR DURATION - SCROLL DURATION - SCROLL DURATION - SCROLL RL AMPS LR AMPS 16.7 109 18.5 124 23.7 152.5 Outdoor Fan FL AMPS 2.80 2.80 2.80 Fan HP 1/3 1/3 1/3 Fan Dia (inches) 26.6 27.6 27.6 Coil SPINE FIN SPINE FIN SPINE FIN Refrigerant R-410A 10 LBS., 5 OZ 10 LBS., 9 OZ 10 LBS., 9 OZ LINE SIZE IN. O.D. GAS (c) 7/8 7/8 7/8 LINE SIZE IN. O.D. LIQ. 3/8 3/8 3/8 Charge Spec. Subcooling 12 F 8 F 8 F Dimensions H x W X D Crated (IN.) 51 x 35.1 x 38.7 51 x 35.1 x 38.7 51 x 35.1 x 38.7 Weight Shipping (lbs.) 277 300 301 Weight Net (lbs.) 227 250 251 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control NA NA NA Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT004 BAYECMT004 BAYECMT004 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 Refrigerant Lineset (d) TAYREFLN3* TAYREFLN3* TAYREFLN3* Service Valve Panel Cover AAYSVPANL0046AA AAYSVPANL0046AA AAYSVPANL0046AA (a) (b) (c) (d) Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. Standard line lengths 60, Standard lift 60 Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub#32 3312 0* (* denotes latest revision).. * = 15, 20, 25, 30, 40 and 50 foot lineset available. MODEL SOUND POWER LEVEL [db (A)] A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL db [db(a)] 63 125 250 4A6H6024H1 71 77 72 68 68 69 60 53 47 4A6H6030H1 70 75 69 68 68 66 62 57 51 4A6H6036H1 70 75 69 68 68 66 62 57 51 4A6H6042H1 72 77 75 72 70 67 62 59 52 4A6H6048H1 72 77 75 72 70 67 62 59 52 4A6H6060H1 72 77 75 72 70 67 62 59 52 500 1000 2000 4000 8000 12-1202-1B-EN 3

Accessory Description and Usage Anti-Short Cycle Timer Solid state timing device that prevents compressor recycling until five (5) minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc. Evaporation Defrost Control SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30 F with TXV. Rubber Isolators Five (5) large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized. Hard Start Kit Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc. Extreme Condition Mount Kit Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc. Model Nomenclature AHRI Standard Capacity Rating Conditions AHRI Standard 210/240 Rating Conditions 1. Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. 2. High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. 3. Low Temperature Heating 17 F DB air entering indoor coil. 4. Rated indoor airflow for heating is the same as for cooling. AHRI Standard 270 Rating Conditions (Noise rating numbers are determiend with the unit in cooling operations.) Standard Noise Rating number is at 95 F outdoor air. 4 A 6 V 0 0 3 6 A 1 0 0 0 A A 4 12-1202-1B-EN

Schematic Diagrams Figure 1. 2.0 Ton Models 12-1202-1B-EN 5

Schematic Diagrams Figure 2. 3.0 Ton Models 6 12-1202-1B-EN

Schematic Diagrams Figure 3. 3.5 5.0 Ton Models 12-1202-1B-EN 7

Outline Drawing Model Base A B C D E F G H J K 4A6H6024H 3 4A6H6030H 4 4A6H6036H 4 4A6H6042H 4 4A6H6048H 4 4A6H6060H 4 832 (32 3/4) 943 (37 1/8) 943 (37 1/8) 1147 (45 1/8) 1147 (45 1/8) 1147 (45 1/8) 829 (32 5/8) 946 (37 1/4) 946 (37 1/4) 946 (37 1/4) 946 (37 1/4) 946 (37 1/4) 651 (29 3/4) 870 (34 1/4) 870 (34 1/4) 870 (34 1/4) 870 (34 1/4) 870 (34 1/4) 3/4 3/8 3/4 3/8 3/4 3/8 7/8 3/8 7/8 3/8 7/8 3/8 127 (5) 143 (5 5/8) 143 (5 5/8) 152 (6) 152 (6) 152 (6) 76 (3) 98 (3 7/8) 98 (3 7/8) 98 (3 7/8) 98 (3 7/8) 98 (3 7/8) 197 (7 3/4) 219 (8 5/8) 219 (8 5/8) 219 (8 5/8) 219 (8 5/8) 219 (8 5/8) 60 (2 3/8) 86 (3 3/8) 86 (3 3/8) 86 (3 3/8) 86 (3 3/8) 86 (3 3/8) 508 (20) 508 (20) 508 (20) 813 (32) 813 (32) 813 (32) 8 12-1202-1B-EN

Mechanical Specification Options General The Outdoor Units are fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115 F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint finish on all louvered panels and the fan top panel. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test. The base is made of a CMBP-G30 weatherproof material to resist corrosion. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory supplied liquid line drier is standard. Some models may require field installation. Compressor The compressor features internal over temperature, pressure protection and total dipped hermetic motor. Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has a cooling capacity to 55 F. The addition of an evaporator defrost control permits operation to 40 F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30 F. Thermostats Cooling only and heat/cooling (manual and automatic change over). Sub-base to match thermostat and locking thermostat cover. Evaporator Defrost Control See Low Ambient Cooling. 12-1202-1B-EN 9

Notes 10 12-1202-1B-EN

Notes 12-1202-1B-EN 11

Notes American Standard optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, American Standard offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.americanstandardair.com. American Standard has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. 2015 American Standard Heating & Air Conditioning 12-1202-1B-EN 20 Feb 2015 Supersedes 12-1202-1A-EN (December 2014)