By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

Similar documents
BDM Direct Vent systems are for use with direct vent gas fired appliances.

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

Installation & Maintenance Instructions

ZC Kit AGP Pellet Insert

PelletVent Multi-fuel venting system. UL 641.

Pellet Stove. Flex Pipe. Appliance Connector

PelletVent Pro. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

SUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

Ventis Direct Vent. Installation Instructions

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

PelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

EXCELPellet FACTORY BUILT PELLET CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS

VP Pellet Pipe. For pellet burning stoves. FEATURES

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro

MODEL CF CEILING SUPPORTED CHIMNEY

Shasta Vent Inc All-Fuel HT Chimney Installation Instructions

Installation and Maintenance Instructions

CVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.

Venting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness

Installation Instructions

VENT SYSTEM COMPONENTS

DuraTech. Installation Instructions. Combustion Air System

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

St. Croix Greenfield Installation Manual

DuraPlus HTC. All-fuel, double-wall chimney system. ULC S629.

Pellet Vent INSTALLATION INSTRUCTIONS

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual.

INSTALLATION INSTRUCTIONS

Ultimate Pellet Pipe

Installation and Maintenance Instructions

Pellet Vent INSTALLATION INSTRUCTIONS

CHAPTER 8 CHIMNEYS AND VENTS

Twin Wall Installation Instructions And Maintenance Guide

INSTALLATION INSTRUCTIONS

CHIMNEYS AND VENTS CHAPTER 8

CHAPTER 8 CHIMNEYS AND VENTS

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

Mitchell Metal Products, Inc.

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10

INSTALLATION INSTRUCTIONS

Venting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Corn Flame Energy Corn Stove Model 3000

INSTALLATION AND MAINTENANCE INSTRUCTIONS. 1700ºF Air-Cooled and Insulated ECO-STEEL Chimney Size 13

ASX7-5-IOM-3 J

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

Installation and Maintenance Instructions

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances

Saf-T Vent Model EZ Seal Plus/EZ 316 Single Wall Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada)

Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

Saf-T Vent SC Plus/SC 316

The Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE

ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS

Installation and Maintenance Instructions

INSTALLATION INSTRUCTIONS

SWB400I DELUXE RADIANT WOOD BURNING FIREPLACE INSTALLATION, OPERATION AND MAINTENANCE MANUAL

X-593 SOLID FUEL HEATING QUESTIONNAIRE

INSTALLATION INSTRUCTIONS

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

Installation and Maintenance Instructions

ASX7-4-IOM-6 J

FasNSeal. Installation Instructions

Technical and Dimensional Data. Saf-T Vent SC Plus

INS A T LL T A ION, OPER T A ING AND SERVICE INSTRUCTIONS FOR FREEDOM CONDENSING HIGH EFFICIENCY DIRECT VENT GAS - FIRED HOT

Installation Manual. Installation and Appliance Setup

DURAVENT POLYPRO VENTING PRODUCTS

STORM COLLAR 3/4" AIR SPACE BACK AND SIDES 31 5 / / /16 LOUVERS ON MODEL 3601 ONLY AIR KIT K/O GAS LINE K/O OUTSIDE AIR (LEFT SIDE ONLY)

Type B Gas Vent. Installation Instructions

2012 INTERNATIONAL FUEL GAS CODE VENTS

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

SEPARATED COMBUSTION WARNING

Installation and Maintenance Instructions. Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent

36" and 42" WOOD BURNING FIREPLACES INSTALLATION AND OPERATING INSTRUCTIONS

SEPARATED COMBUSTION. General WARNING

INSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS

SOUTHWEST FIREBIRD MFG Sonoran Model 36ST, 42ST

INSTALLATION INSTRUCTIONS SAVE THIS BOOK

PelletVent. Factory-Built Chimney Relining. Installation Instructions. PelletVent Pro (PVP)

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

POWER VENT. Standard Power Vent, Fan Type Unit Heaters: Standard Power Vent, Blower Type Unit Heaters: General WARNING WARNING. Model UDAP & Model APD

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. OWNER S MANUAL

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

Direct Vent System. for PELLET STOVES FEATURES. Includes all Selkirk Model VP Pellet Pipe and Direct-Temp components needed to complete a system

DIRECT-VENT FIREPLACE

Transcription:

By Bernard Dalsin Mfg. Co. 5205 208 th St Farmington MN 55024 L-VENT TYPE 3 "and 4" Factory-built venting system for wood pellet, corn or biomass and low-temperature gas or liquid fuel appliances Installation and Operating Instructions Read these instructions and keep them for future reference Contact local building or fire officials about restrictions, installation inspection, and permit that may be required in your area. A MAJOR CAUSE OF CHIMNEY-RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS CRITICAL THAT THIS VENT SYSTEM BE INTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS. Listed to UL 641-2009, ULC S609-M89, and ULC/ORD-C441-1992, Report No. 369-P-01b-2 1 Rev. 06/11

GENERAL INSTALLATION NOTES Install the Bio Vent as described in these instructions. Only use parts supplied by Bernard Dalsin Mfg. Co., they will provide clearances necessary for a safe installation. Failure to do so will void the certification of this vent system. Gaskets MUST BE Lubricated (Soap or Vaseline) THE MINIMUM CLEARANCE TO COMBUSTIBLE IS: 1 in USA & CANADA. 1. The Bio Vent is intended for use with wood pellet or corn burning appliances and low temperature gas or liquid fuel burning appliances that are approved for use with type L venting systems. 2. Caulking of vent joints is not required because Bio Vent comes with factory installed silicone gaskets. 3. Maximum vent supporting height is: Vent Size: 3 4 Ceiling Support: 45 45 Tee Support: 45 45 4. The Vent termination cap shall extend at least 12 higher than any wall or roof around the pipe. 5. When passing through ceilings and walls, only use required firestops and thimbles and make sure all combustible materials are a minimum of 1 away from the vent. 6. Do not fill the 1 air space around the vent with insulation or any other material. Insulation placed in this area could cause adjacent combustible to overheat. In unoccupied attic, a flat ceiling firestop with integrated insulation shield or an enclosure having a fire resistance rating equal to or greater than that of the floor or roof assembly should be used to avoid any contact from the insulation with the vent. 7. Never choose a vent with an inside diameter that is smaller than the appliance s outlet. 2 Rev. 06/11

8. When exiting through the wall, make sure the local building code rules are followed for distance from windows and openings. 9. Bio Vent must be installed so easy access can be provided for inspection and cleaning. 10.Do not use chemical cleaner, they can damage the vent pipe. 11.Bernard Dalsin Mfg. is not responsible for flue by-products that might discolor roofs or walls. 12. Have your chimney cleaned at least twice per year (more based on use of the appliance) by a certified sweep or contractor. If you do it yourself, never use a stiff metallic brush; always use a plastic or flexible steel brush. GENERAL INSTALLATION NOTES 1. Always follow the appliance manufacturer s instruction carefully. a. Choose an appliance that is listed by a recognized testing laboratory. b. Connect only one appliance per flue. c. Always maintain the appliance manufacturer s specified minimum clearances. d. Choose a location that will minimize offsets to allow the appliance to vent optimally. e. Do not install damaged parts. 2. The vent can be installed either vertically (see figure 1), horizontally (see figure 2), or both (see figure 3) depending on your appliance location. 3. Always use Bernard Dalsin Bio Vent wall thimble, support, or firestop and accessories to ensure proper fitting of the installation. 4. The Bio Vent can also be installed inside a masonry chimney. 3 Rev. 06/11

VERTICAL INSTALLATION 1. Locate appliance according to manufacturer s instruction and required clearances. 2. Drop a plumb bob over the center of the flue outlet and mark center point on the ceiling. 3. Cut and frame the holes in the floor, ceiling, and roof where the vent will pass through. For 3 pipe; the framing dimensions will be 6 ½ x 6 ½ For 4 pipe; the framing dimensions will be 7 ½ x 7 ½ 4. From above, place the support on the floor in the center of the hole. Nail it using #8-2 nails. 5. If going through an attic, install the flat ceiling firestop support kit which includes an attic insulation shield and the support. Adjust its height to the maximum possible within the space available. Note: A decorator collar should be installed over the ceiling firestop for a more finished look. Note: You may replace the firestop and support with the cathedral roof support if you are going through a vaulted roof. 6. Connect the appliance adaptor to the stove. If the outlet of the appliance is at the back, attach a tee before stacking up the flue sections. 7. Attach a support bracket at base of tee and secure it to a sturdy location on the wall in order to support the tee and pipe above. 8. Attach each section of pipe by pushing male and female ends of pipe together until it bottoms out. (up to indent on outer shell). 9. Install three screws at each section of the pipe. Only install screws at the top ½ section of pipe. (Never put screws below ½ as you will pierce the pipe.) Note: Use only 1/4 screws provided and never use screws that are long enough to pierce the inner section of pipe. 10.When pipe passes through fire-stop and support at ceiling, install and tighten a support clamp around the vent, then secure it by using (3) ¼ long metal screws through the collar and into the vent casing. Be sure the screw does not penetrate into the inner flue. 4 Rev. 06/11

11. Stack the sections until the required vent height is reached. Note: If elbows are needed, a wall strap must be installed over the deviation. 12.At each floor or ceiling through which the vent passes, install a fire-stop and support clamp below the floor. 13. If you are building a chase whereby enclosing the vent run; a chasing box will need to be installed to provide cooling at the base and top of the chase. (See pages 13 & 14.) 14.Put the roof flashing in place. Note: Nail the flashing to the roof using roofing nails. Seal the joint between the roof and flashing with roof caulking or appropriate material. 15.For pitched roofs, place the flashing under the upper shingles and on top of the lower shingles. 16.Place the storm collar over the vent pipe and the flashing. Seal the joint between the vent and collar with silicon caulking 17. Fit the vertical termination cap to the top of the vent. Secure it by pushing it down on the vent until it snaps in place. Secure with three ¼ metal screws. 5 Rev. 06/11

1 Clearance Per Appliance mfg. Insulation must maintain 1 clearance Maintain 1 clearance to combustibles from vent pipe. Bio Vent 1 Min. (USA) or 1 Min (Canada) Outside air kit available from BDM. 6 Rev. 06/11

HORIZONTAL INSTALLATION 1. Locate your appliance according to manufacturer s instruction and clearance requirements. Be sure to abide by your local building code regulations for minimum distance of flue exhaust from windows and openings. In absence of overriding local requirement, use the following rules as depicted in figure 5.0. Pellet Vent Termination Vent must terminate on the exterior of the dwelling. Horizontal terminations must protrude a minimum of 12" (305 mm) from the wall. Vertical terminations must protrude a minimum of 24" (610 mm) from the roof surface. In addition, all clearances listed below must be met. Must have an approved cap (to prevent water from entering) or a 45 downturn with a rodent screen. If the termination is located on a windy side of the house, an approved house shield is recommended to prevent soot from building on the side of the house. Must not be located where it will become plugged by snow or other material. WARNING: Side wall venting shall not exceed 48 (1200 mm). Minimum Clearances A. 4 ft (1220 mm) below or beside any door or window that opens. 1 ft (305 mm) below or beside any window that does not open. B. 1 ft (305 mm) above any door or window that opens. C. 39.5 inches (1 m) from any adjacent building. D. 7 ft (2.134 m) above any grade when adjacent to public walkways. NOTE: Vent may not terminate in a covered walkway or breezeway. 7 Rev. 06/11

E. 2 ft (610 mm) above any grass, plants or other combustible materials. F.5 ft 10 in (1.8 m) from any forced-air intake of any other appliance. G. 5 ft 10 in (1.8 m) from a gas service regulator vent outlet. H. 2 ft (610 mm) below eaves or overhangs. I. 1 ft (305 mm) horizontally from a combustible wall. J. 1 ft (300 mm) above grade. X. Must be a minimum of 2 ft (610 mm) above the roof. HORIZONTAL INSTALLATION (con t) 2. Cut and frame a hole in the wall, where the vent will pass through Note: For required 1 clearance a 6 ½ x 6 ½ square hole must be cut and framed when using 3 Bio Vent pipe. A 7 ½ x 7 ½ square hole must be cut and framed when using 4 Bio Vent pipe. 3. Install the wall Thimble by bending the tabs according to required clearance. Note: The wall thimble interior and exterior sleeves must always overlap at least 1 when going through a combustible wall. Extensions are available or can be made in the field. 4. Seal the joint between the wall thimble and the outside wall with silicone caulking. 5. Install the decorator collar to the interior wall with supplied screws. 6. Install the exterior wall flashing to the exterior wall. Caulk around perimeter of flashing. 7. Connect the first piece of pipe (or appliance adaptor if necessary) to the back of the stove and attach sufficient pipe to penetrate wall thimble and extend at least 12 (recommended but not required) beyond exterior wall. 8. Fit the horizontal termination cap to the end of the Bio Vent and secure it tightly in place by pushing it down until it bottoms out. Secure with three ¼ metal screws. (Screws are not required) Note: When using standard horizontal termination or 45 degree horizontal cap always make sure the base of the cap is at a minimum of 12 (recommended but not required) away from the exterior of the house. The 45 degree cap must be pointed in a downward direction. 8 Rev. 06/11

Rain Cap Removal: Remove the three 1/4" sheet metal screws. Then lift the rain cap off of the pipe. Bio Vent Maintain 1 clearance to combustibles from vent pipe. 9 Rev. 06/11

MASONRY INSTALLATION 1. Have your masonry chimney inspected by a qualified chimney sweep or installer to determine its condition. 2. Determine the length of rigid sections needed (subtract 2 per joint). Note that the flexible pipe is ordered to length. See BDM catalog for Stainless Steel Flex liner. 3. Install the appropriate size support plate on top of the masonry chimney with masonry anchor bolts. 4. Assemble the first piece of rigid Bio Vent section to the flex pipe. Lowering the assembly in the chimney, connect the remaining sections until the desired length is reached. 5. Use stainless steel ¼ long sheet metal screws to attach Bio Vent to the flex liner. Be careful not to penetrate the inner flue liner of the Bio Vent. Note: The flex liner can only be used inside the masonry chimney. a. Assemble and tighten the support clamp just above the support plate collar letting it rest on the collar for support. Install a storm collar above the support clamp. b. Install the vertical termination cap to the last section of pipe by pushing down on the cap until it snaps into place. Secure with three ¼ stainless steel sheet metal screws. Be careful not to penetrate the inner flue of the vent. c. Connect the flex pipe to the Tee or the stove. 10 Rev. 06/11

Bio Vent Bio Vent 1 minimum 11 Rev. 06/11

Installation Example: Masonry Chimney 12 Rev. 06/11

Constructing a chase for multi-floor installation Attic Insulation Chasing Box Flat Ceiling Firestop Chase Vent Wood Chase Chase Vent Bio Vent Pipe 2 nd Floor Flat Ceiling Firestop 1 st Floor Decorator Collar Chase Construction and Framing Dimensions: I.D. of Chase O.D. of Chase Framing Dimensions 3 Bio Vent Pipe 6 ½ x 6 ½ min. 7 ½ x 7 ½ 6 ½ x 6 ½ 4 Bio Vent Pipe 7 ½ x 7 ½ min. 8 ½ x 8 ½ 7 ½ x 7 ½ 13 Rev. 06/11

Constructing a chase for multi-floor installation 1. Using a plumb bob mark the location where the center of the pipe will pass through each floor and ceiling. 2. At 1 st floor ceiling cut and frame a 6 ½ x 6 ½ or 7 ½ x 7 ½ hole depending upon either 3 or 4 pipe respectively. 3. Install a flat ceiling firestop and support clamp securing to the required framing above. 4. Install a decorator collar over the installed flat ceiling firestop. 5. Run the Bio Vent pipe from the stove up through the first floor and firestop assembly. 6. At 2 st floor ceiling cut and frame a 6 ½ x 6 ½ or 7 ½ x 7 ½ hole depending upon either 3 or 4 pipe respectively. 7. Install a flat ceiling firestop and support clamp securing to the required framing above. 8. Install a chasing box directly below the flat ceiling firestop and screw to required framing. 9. Connect the required sections of Bio Vent Pipe until you have run through the 2 nd floor flat ceiling firestop assembly. 10. With ½ x ½ sheet rock, construct a chase (with I.D. and O.D. requirements listed on previous page); while insuring that the pipe is centered within the chase. Construct the chase from floor to ceiling and around firestop assemblies. Always maintain at least 1 clearance between pipe and chase material. Construct chase of materials allowed by national, state, and local codes. 11. Cut a 5 W x 4 H hole at the base of chase and install a chase vent directly over cut hole. 12. Cut a 5 W x 4 H hole at top of chase directly over the 5 x 4 hole in the previously installed chasing box assembly. 13. Install a chase vent over the hole cut at top of chase. 14. continue to install Bio Vent pipe sections in attic and out roof following the procedures described in vertical installation on pages 4 through 6. 14 Rev. 06/11

BIO VENT By Bernard Dalsin Mfg. Co. PART # DESCRIPTION 71010603 3'' X 6" BIO VENT PIPE 71010603B 3'' X 6" BIO VENT PIPE BLACK 71010604 4'' X 6'' BIO VENT PIPE 71010604B 4'' X 6'' BIO VENT PIPE BLACK 71011203 3'' X 12" BIO VENT PIPE 71011203B 3'' X 12" BIO VENT PIPE BLACK 71011204 4'' X 12'' BIO VENT PIPE 71011204B 4'' X 12'' BIO VENT PIPE BLACK 71011803 3'' X 18" BIO VENT PIPE 71011803B 3'' X 18" BIO VENT PIPE BLACK 71011803SS 3'' X 18" BIO VENT PIPE (ALL S.S.) 71011804 4'' X 18'' BIO VENT PIPE 71011804B 4'' X 18'' BIO VENT PIPE BLACK 71011804SS 4'' X 18'' BIO VENTPIPE (ALL S.S.) 71012403 3'' X 24" BIO VENT PIPE 71012403B 3'' X 24" BIO VENT PIPE BLACK 71012404 4'' X 24'' BIO VENT PIPE 71012404B 4'' X 24'' BIO VENT PIPE BLACK 71013603 3'' X 36" BIO VENT PIPE 71013603B 3'' X 36" BIO VENT PIPE BLACK 71013604 4'' X 36'' BIO VENT PIPE 71013604B 4'' X 36'' BIO VENT PIPE BLACK 71011103 3'' X 3''-10" BIO VENT SLIP JOINT 71011103B 3'' X 3''-10" BIO VENT SLIP JOINT BLACK 71011104 4'' X 3''-10'' BIO VENT SLIP JOINT 71011104B 4'' X 3''-10'' BIO VENT SLIP JOINT BLACK 71024503 3'' 45 DEG BIO VENT 1 PC ELBOW 71024503B 3'' 45 DEG BIO VENT 1 PC ELBOW BLACK 71024504 4'' 45 DEG BIO VENT 1 PC ELBOW 71024504B 4'' 45 DEG BIO VENT 1 PC ELBOW BLACK 71029003 3'' 90 DEG BIO VENT 1 PC ELBOW 71029003B 3'' 90 DEG BIO VENT 1 PC ELBOW BLACK 71029004 4'' 90 DEG BIO VENT 1 PC ELBOW 71029004B 4'' 90 DEG BIO VENT 1 PC ELBOW BLACK 71040103 3'' VERTICAL BIO VENT CAP 71040104 4'' VERTICAL BIO VENT CAP 71030203 3'' HORIZONTAL BIO VENT JET CAP 71030204 4'' HORIZONTAL BIO VENT JET CAP 71030103 3'' HORIZONTAL BIO VENT TERM CAP 71030104 4'' HORIZONTAL BIO VENT TERM CAP 71050303 3'' X 3'' BIO VENT TEE W/ END CAP 71050303B 3'' X 3'' BIO VENT TEE BLACK W/ END CAP 71050304 4'' BIO VENT TEE W 3'' BRANCH W/ END CAP 71050304B 4'' BIO VENT TEE W 3'' BRANCH BLACK W/ END CAP 71050404 4'' X 4'' BIO VENT TEE W/ END CAP 71050404B 4'' X 4'' BIO VENT TEE BLACK W/ END CAP 71050303ST 3" X 3" BIO VENT STARTER TEE W/ END CAP 71050303STB 3" X 3" BIO VENT STARTER TEE BLACK W/ END CAP 71050304ST 4" BIO VENT STARTER TEE W 3" BRANCH W/ END CAP 71050304STB 4" BIO VENT STARTER TEE W 3" BRANCH BLACK W/ END CAP 71050404ST 4" X 4" BIO VENT STARTER TEE W/ END CAP 71050404STB 4" X 4" BIO VENT STARTER TEE BLACK W/ END CAP 71050303DT 3'' X 3'' BIO VENT DOUBLE TEE W/ 2 END CAPS 71050303DTB 3'' X 3'' BIO VENT DOUBLE BLACK TEE W/ 2 END CAPS 71050304DT 3'' X 4'' BIO VENT DOUBLE TEE W/ 2 END CAPS 15 Rev. 06/11

71050304DTB 3'' X 3'' BIO VENT DOUBLE BLACK TEE W/ 2 END CAPS 71050404DT 4" X 4'' BIO VENT DOUBLE TEE W/ 2 END CAPS 71050404DTB 4" X 4'' BIO VENT DOUBLE BLACK TEE W/ 2 END CAPS 71060003 3'' BIO VENT END CAP 71060004 4 BIO VENT END CAP 71090304 3'' TO 4'' APPLIANCE ADAPTOR/INCREASER BIO VENT 71090304B 3'' TO 4'' APPLIANCE ADAPTOR/INCREASER BLACK BIO VENT 71080003 3'' BIO VENT APPLIANCE ADAPTOR 71080003B 3'' BIO VENT APPLIANCE ADAPTOR W GASKET BLACK 71080004 4'' BIO VENT APPLIANCE ADAPTOR W GASKET 71080004B 4'' BIO VENT APPLIANCE ADAPTOR W GASKET BLACK 71081003 3" BIO VENT APPLIANCE COLLAR EXTENSION 71091303 3" TO 3" FLEX TO PIPE ADAPTOR/INCREASER BIO VENT 71091304 3" TO 4" FLEX TO PIPE ADAPTOR/INCREASER BIO VENT 71091404 4" TO 4" FLEX TO PIPE ADAPTOR/INCREASER BIO VENT 71094303 3" TO 3" PIPE TO FLEX ADAPTOR/INCREASER BIO VENT 71094304 3" TO 4" PIPE TO FLEX ADAPTOR/INCREASER BIO VENT 71094404 4" TO 4" PIPE TO FLEX ADAPTOR/INCREASER BIO VENT 71092603 3" TO 6" CLASS "A" PIPE ADAPTOR/INCREASER / MASONRY ADAPTOR BIO VENT 71092604 4" TO 6" CLASS "A" PIPE ADAPTOR/INCREASER / MASONRY ADAPTOR BIO VENT 71092803 3" TO 8" CLASS "A" PIPE ADAPTOR/INCREASER BIO VENT 71092804 4" TO 8" CLASS "A" PIPE ADAPTOR/INCREASER BIO VENT 71080003HS 3" HARMAN STOVE APPLIANCE ADAPTOR 71080003BHS 3" HARMAN STOVE APPLIANCE ADAPTOR BLACK 71080004TRV 4" BIO VENT TRAVIS APPLIANCE ADAPTOR W/ GASKET 71080004TRVB 4" BIO VENT TRAVIS APPLIANCE ADAPTOR W/ GASKET BLACK 71080003ETB 3" ECOTECK BIO VENT APPLIANCE ADAPTOR W/ GASKET BLACK 71080003STETB 3"X3" ECOTECK BIO VENT STARTER TEE BLACK W/ END CAP 71121203 3'' BIO VENT OUTSIDE SS WALL FLASHING W GASKET 3'' CLEARANCE 71121204 4'' BIO VENT OUTSIDE SS WALL FLASHING W GASKET 3'' CLEARANCE 71201203 3'' BIO VENT FLAT CEILING FIRESTOP SUPPORT 3'' CLEARANCE 71201204 4'' BIO VENT FLAT CEILING FIRESTOP SUPPORT 3'' CLEARANCE 71210003 3" VERTICAL SUPPORT CLAMP 71210004 4" VERTICAL SUPPORT CLAMP 712603KT 3'' BIO VENT CATHEDRAL SUPPORT KIT 712604KT 4'' BIO VENT CATHEDRAL SUPPORT KIT 71101203 3'' TELESCOPING WALL THIMBLE 3'' CLEARANCE BIO VENT 71101204 4'' TELESCOPING WALL THIMBLE 3'' CLEARANCE BIO VENT 71111203 3'' INSIDE DECORATOR CLR BLACK W GASKET 3'' CLEARANCE BIO VENT 71111204 4'' INSIDE DECORATOR CLR BLACK W GASKET 3'' CLEARANCE BIO VENT 71220103 3 GALVANIZED ADJUSTABLE WALL STRAP 71220104 4 GALVANIZED ADJUSTABLE WALL STRAP 71440203 3" X 24" BIO VENT DELUXE TERMINATOR W 2 COLLAR 71440204 4" X 24" BIO VENT DELUXE TERMINATOR W 2 COLLAR 71440303 3" X 24" BIO VENT DELUXE TERMINATOR W 3 COLLAR 71440304 4" X 24" BIO VENT DELUXE TERMINATOR W 3 COLLAR 71450002 2 BIO VENT FRESH AIR INTAKE KIT 71450003 3 BIO VENT FRESH AIR INTAKE KIT 95270225 2 X 25 ALUMINUM FLEX ONLY W/O ENDS 9550030445 3 x 45 ALUMINUM INSULATED FLEX 9550040545 4 X 45 ALUMINUM INSULATED FLEX 711403KT 3'' BIO VENT WALL VENT KIT 3'' CLEARANCE 711404KT 4'' BIO VENT WALL VENT KIT 3'' CLEARANCE 713003KT 3 BIO VENT FLAT CEILING VENT KIT 713004KT 4 BIO VENT FLAT CEILING VENT KIT 71410104 3 BIO VENT ADJUSTABLE FLASHING & STORM COLLAR KIT 71410105 4 BIO VENT ADJUSTABLE FLASHING & STORM COLLAR KIT 71400103 3" BIO VENT GASKET 71400104 3" BIO VENT GASKET 71400201 BIO VENT TOUCH-UP PAINT 16 Rev. 06/11