DESIGN & TECHNICAL MANUAL

Similar documents
DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

6. DUCT TYPE AR 60FUAK, AR 60UUAK

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

Air Conditioner CONTENTS

OUTDOOR AIR UNIT DTV_OAE034E_03--CHAPTER

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

Digital Inverter 4 series 8 & 10HP

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

HEAT & COOL MODEL (REVERSE CYCLE)

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Cassette type Duct type Ceiling type INVERTER AO* G45LETL AO* G54LETL

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

2 &3-4 Head Multi System

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

Air to Air Heat Exchanger

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

DESIGN & TECHNICAL MANUAL

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

Compact 4-way Cassette ( ) Type

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

Small VRF system. for light commercial and home use SERVICE MANUAL

Come home to a warm welcome

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

SERVICE MANUAL MLZ-KA25VA - MLZ-KA35VA - MLZ-KA50VA - E1 INDOOR UNIT. No. OBH483. Ceiling cassette type Models

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

CASSETTE TYPE AIR CONDITIONER

SERVICE MANUAL INDOOR UNIT MFZ-KA25VA - MFZ-KA50VA - MFZ-KA35VA - No. OB409. Models. Revision E: SPLIT-TYPE AIR CONDITIONERS REVISED EDITION-E

3. INDOOR UNIT OPERATION

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

TECHNICAL CATALOGUE MONO SPLIT RAK-25PSC RAK-35PSC RAC-35WSC

CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS.

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

250mm dia straight pipe length SP4 SP3. Air volume

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SERVICE MANUAL MSZ-GE22VA - E1 MSZ-GE25VA - E1 MSZ-GE35VA - E1 MSZ-GE42VA - E1 MSZ-GE50VA - E1 MSZ-GE60VA - E1 MSZ-GE71VA - E1 INDOOR UNIT. No.

FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

FLOOR CONSOLE / UNDER CEILING DUAL type

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

Highly Efficient,Powerful Heating and Cooling.

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Ducted inverter reverse cycle air conditioning

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Fujitsu OPERATING MANUAL Air Conditioner DUCT TYPE

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

Air Conditioner SVC MANUAL(Exploded View)

The Intelligent Choice in Comfort

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Transcription:

AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR AR GLLTB AR G4LLTB AR G8LLTB OUTDOOR AO GLALL AO G4LALL AO G8LALL

. INDOOR UNIT : AR GLLTB AR G4LLTB AR G8LLTB DTR_AR54E_ 3..8

. INDOOR UNIT CONTENTS. FEATURES... -. WIRED REMOTE CONTROLLER... - 3. SPECIFICATIONS... - 4 4. DIMENSIONS... - 6 5. WIRING DIAGRAMS... - 6. CAPACITY TABLE... - 6-. COOLING CAPACITY... - 6-. HEATING CAPACITY... - 7. FAN PERFORMANCE... - 3 7-. AIR VELOCITY DISTRIBUTIONS... - 3 7-. FAN PERFORMANCE CURVE... - 9 7-3. AIRFLOW... - 5 8. OPERATION NOISE (SOUND PRESSURE)... - 8 8-. NOISE LEVEL CURVE... - 8 8-. SOUND LEVEL CHECK POINT... - 3 9. ELECTRIC CHARACTERISTICS... - 3. SAFETY DEVICES... - 3. EXTERNAL INPUT & OUTPUT... - 33 -. EXTERNAL INPUT... - 33 -. EXTERNAL OUTPUT... - 34. FUNCTION SETTINGS... - 37 -. INDOOR UNIT... - 37 -. INDOOR UNIT (Setting by remote controller)... - 39-3. WIRED REMOTE CONTROLLER... - 44 3. OPTIONAL PARTS... - 45 3-. CONTROLLER... - 45 3-. OTHERS... - 45

- ( - ) - FEATURES MODELS AR GLLTB / AO GLALL AR G4LLTB / AO G4LALL AR G8LLTB / AO G8LALL AR GLLTB AR G4LLTB AR G8LLTB FEATURES zenergy efficiency class MODEL AR GLLTB AR G4LLTB AR G8LLTB Cooling A+ A+ A++ Heating A+ A A+ zslim design The slim design allows installations where ceilings are narrow. Drain port zair - intake Air intake direction can be selected to match the installation site. Drain pump zcompact design Condensate lift-up to 85mm. Height 98mm Drain pump built-in Bottom side zflexible installation Ceiling concealed Back side Max. 85mm Drain hose is standard accessory Wall concealed zselectable wide range of static pressure By using DC fan motor, it is possible to change static pressure range from to 9Pa. The change of static pressure range is possible by remote controller. Static pressure range [Pa] 9 Air flow rate [m 3 /h] zfilter (Accessory) Filter : pcs.

WIRED REMOTE CONTROLLER FEATURES zhigh performance and compact size ¾¾Various timer setup available (ON / OFF / WEEKLY). ¾¾Equipped with weekly timer as standard function. ( sets of start/stop per day for a week.) ¾¾When setting up the timer, operation mode and temperature setup can be changed. ¾¾When a failure occurs, the error code is displayed. ¾¾Error history. (Last 6 error codes can be accessed.) ¾¾Up to 6 indoor units can be simultaneously controlled. ¾¾The room temperature is detected and controlled accurately by the built-in thermo sensor. zsimple function setting Setting of the air conditioner selection function is performed by remote controller. zaccurate and comfortable Indoor temperature can be detected accurately by the inclusion of a thermo sensor in the body of the wired controller. Our system can correspond to various scenes. This wired remote controller and the optional remote sensor allows flexibility in sensor location, and suitable for all requirements. zbuilt-in timers Sensor part Thermo sensor display Control part for changing the thermo sensor Weekly timer Possible to set ON/OFF time to operate twice each day of the week. SU MO TU WE TH FR SA Easy-to-understand time bar display Setback timer Possible to set temperature for two time spans and for each day of the week. SU MO TU WE TH FR SA 7 7 SU MO TU WE TH FR SA 3 6 9 5 8 3 6 9 5 8 Setup screen example (Set to Wednesday: 8: to :.) 4 C 3 6 9 5 8 Screen after setup Setup screen example (Set from Sunday to Saturday: : to 5:, 8 C.) 8 C 3 6 9 5 8 Time At "Weekly timer" + "Set back timer" setup 4 C 3 6 9 5 8 Time 8 C 4 C 8 C 4 C zeasy-to-understand operation Timer area Operation area 3 6 9 5 8 Time zsimple installation Components are compatible with standard switch boxes. Flat back construction allows equipment to be installed wherever it is needed. [Variable timer control] The operation/display sections are zoned according to time and operation, enabling variable programming to match application. - ( - ) - European switch box JIS box

- ( - 3) - FUNCTIONS START/STOP button Pressed to start and stop operation. SET TEMP. button Selects the setting temperature. 6 3 7 4 8 3 9 5 5 4 3 MODE button Selects the operating mode (AUTO, HEAT, FAN, COOL, DRY). 4 FAN button Selects the fan speed (AUTO, QUIET, LOW, MED, HIGH). 5 ECONOMY (THERMO SENSOR) button Turns the economy efficient mode on and off. 6 TIMER MODE (CLOCK ADJUST) button Selects the timer mode (OFF TIMER, ON TIMER, WEEKLY TIMER). Sets the current time. 7 DAY (DAY OFF) button Temporarily cancels one day timer. Display panel 6 9 8 7 8 SET BACK button Pressed to select the set back timer. 9 Set time button Pressed to set time. TIMER DELETE button Deletes the weekly timer schedule. TIMER SET button Sets the date, hour, minute and on-off time. Vertical airflow direction and swing button Push for two seconds to change the swing mode. DIMENSION [ Unit : mm ] 8 3 Horizontal airflow direction and swing button Push for two seconds to change the swing mode. 4 FILTER RESET button 5 Operation lamp Lights during operation and when the timer is on. 6 Timer and clock display 7 Operation mode display 8 Fan speed display 9 Operation lock display Temperature display Function display Defrost display Thermo sensor display Economy display Front View SPECIFICATION Side View Vertical swing display Horizontal swing display Filter display SIZE (H W D mm) 8 WEIGHT (g) 6 Functions will be different due to type of indoor unit. For details, please see operation manual. CABLE LENGTH (m) POWER (V) WIRING SPECIFICATIONS Use Cable size Wire type Remarks Remote controller cable.33 mm ( AWG) Polar 3 core Use sheathed PVC cable

- ( - 4) - 333SPECIFICATIONS Type DUCTED MODEL INVERTER HEATPUMP Model name AR GLLTB AR G4LLTB AR G8LLTB Power source 3V ~ 5Hz Available voltage range 98-64V ~ 5Hz Capacity Cooling Rated kw 3.5 4.3 5. Btu/h 95 465 77 Min - Max kw.9-4.4.9-5.4.9-5.9 Btu/h 3-5 3-84 3 - Heating Rated kw 4. 5. 6. Btu/h 4 75 5 Min - Max kw.9-5.7.9-6.5.9-7.5 Btu/h 3-94 3-3 - 56 Input power Rated.5.33.6 Cooling Max.7.4.4 kw Rated..34.66 Heating Max.6.83.83 Current Cooling 4.8 6. 7. Rated A Heating 5. 6. 7.4 EER Cooling 3.33 3. 3. kw / kw COP Heating 3.69 3.7 3.6 Moisture removal l/h (pints/h).3 (.3).5 (.6). (3.5) Maximum operating current * Cooling 7.5 9. 9. A Heating..5.5 High 65 8 94 Cooling Med 6 7 88 Low 55 6 8 Fan Airflow Quiet 48 48 75 m 3 /h rate High 65 8 94 Med 6 7 88 Heating Low 55 6 8 Quiet 48 48 75 Type Q'ty Sirocco Sirocco 3 Motor output W 8 96 Recommended static pressure Pa to 9 High 9 3 3 Cooling Med 8 3 3 Low 6 8 9 Sound pressure level Quiet 5 6 7 db (A) High 9 3 3 Heating Med 8 3 3 Low 6 8 9 Quiet 4 5 7 Dimensions (H W D) mm 94 5 39.9 94 7 39.9 Fin pitch.3 Heat exchanger type Rows Stages 3 4 Pipe type Copper tube Fin type Aluminium Enclosure Material GALVANIZED STEEL SHEET Colour Dimensions Net 98 7 6 98 9 6 mm (H W D) Gross 76 968 77 76 68 77 Weight Net 9 3 kg Gross 3 7 Liquid Ø6.35 (Ø/4 in.) Size mm Connection pipe Gas Ø9.5 (Ø3/8 in.) Ø.7 (Ø/ in.) Method Flare C 8 to 3 Cooling Operation range %RH 8 or less Heating C 6 to 3 Remote controller type Wired [Wireless (option)] Drain hose Material HARD PVC Size mm Ø5(I.D.), Ø3(O.D.) Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 7 CDB / 9 CWB.and outdoor temperature of 35 CDB / 4 CWB. Heating : Indoor temperature of CDB / 5 CWB.and outdoor temperature of 7 CDB / 6 CWB. Standard static pressure : 5Pa Pipe length : 5 m, Height difference : m.(outdoor unit - Indoor unit) Sound pressure level : Install a m duct to the outlet port and a m duct to the suction poit and measure. The maximum current is the maximum value when operated within the operation range. The protective function might work when using it outside the operation range.

- ( - 5) - Model name ARÜGLLTB ARÜG4LLTB ARÜG8LLTB Energy efficiency class Cooling A+ A+ A++ Heating (Average) A+ A A+ Pdesign Cooling 3.5(35 C) 4.3(35 C) 5.(35 C) kw Heating (Average) 4.(- C) 4.5(- C) 5.(- C) SEER Cooling 5.9 5.8 6. kwh/kwh SCOP Heating (Average) 4. 3.9 4. Annual energy consumption QCE 7 59 93 kwh/a QHE (Average) 467 64 774 Sound power level Cooling 58 6 58 High db (A) Heating 58 6 58

- ( - 6) - 444DIMENSIONS MODELS: AR GLLTB, AR G4LLTB (Unit : mm) 574 5 74 5 Rear view 7 View A (Drain hose) 3 Drain port 69 44 64 367 6 377 x 6 = 6 47 65 734 55 89 78 48 9 Top view 8 63 Side view 98 68 5 78 55 43 65 664 7 3 Front view Bottom view AR GLL AR G4LL Refrigerant pipe flare Liquid ø 6.35 mm (ø /4 in.) connection Gas ø 9.5 mm (ø 3/8 in.) ø.7 mm (ø / in.) Drain hose connection Drain hose I.D. 5mm, O.D. 3mm (VP5)

- ( - 7) - MODEL : AR G8LLTB Unit : mm 774 5 74 7 5 Rear view View A 3 (Drain hose) Drain port 69 44 64 367 6 377 x 8 = 8 85 47 55 78 934 89 Top view 56 87 9 63 Side view 98 68 5 78 55 43 3 85 864 9 Front view Bottom view AR G8LL Refrigerant pipe flare Liquid ø 6.35 mm (ø /4 in.) connection Gas ø.7 mm (ø / in.) Drain hose connection Drain hose I.D. 5mm, O.D. 3mm (VP5)

- ( - 8) - INSTALLATION PLACE Unit : mm 3 or more Strong and durable ceiling Left side or more Indoor unit 3 or more Right side 4 or more or more or more Service access Ceiling 5 or more (When no ceiling) Floor or less or less Left side Right side (PIPE side) Grill 5 or more or more Strong and durable floor 3 or more Inlet air Strong and durable floor or more or more 5 or more Left side Right side (PIPE side) Dact Grill 5 or more or more Strong and durable floor 3 or more Inlet air Strong and durable floor or more or more 5 or more

- ( - 9) - MAINTENANCE SPACE Provide a service access for inspection purposes as shown below. Do not place any wiring or illumination in the service space, as they will impede service. Unit : mm Service access Unit Control box 3 or more or more 3 or more Service space

- ( - ) - 555WIRING DIAGRAMS MODELS : AR GLLTB, AR G4LLTB, AR G8LLTB 3 4 5 CN CN5 CN7 GRAY GRAY CN8 BLACK BLACK CN3 3 4 5 6 THERMISTOR (PIPE TEMP.) THERMISTOR (ROOM TEMP.) FLOAT SWITCH LOUVER (OPTION) BLACK BLACK 3 HEATER (OPTION) 3 4 5 3 CN CN9 CN PRINTED CIRCUIT BOARD (MAIN) CN4 3 4 5 6 7 8 3 4 5 6 7 8 GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY CN 3 3 GRAY GRAY GRAY RECEIVER UNIT (OPTION) RED WHITE BLACK FRESH AIR (OPTION) FM BROWN YELLOW WHITE BLACK RED 3 4 5 6 3 4 5 6 W5 W W RED WHITE BLACK TERMINAL 3 E E E3 GREEN GREEN GREEN YELLOW YELLOW WHITE WHITE CN3 CN4 CN6 3 4 5 6 7 3 3 TERMINAL 3 TO REMOTE CONTROL UNIT FAN MOTOR CN5 3 4 5 6 7 8 3 4 5 6 7 8 CN4 3 3 CN PRINTED CIRCUIT BOARD (POWER) CN3 CN CN6 CN8 3 3 3 DRAIN PUMP MOTOR M REACTOR

- ( - ) - 666CAPACITY TABLE 66666COOLING CAPACITY This table is created using the maximum capacity. MODEL: AR GLLTB AFR.8 Outdoor temperature Indoor temperature CDB 8 3 5 7 9 3 CWB 5 6 8 9 3 CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP - 3.5.7.3 3.9.7.3 4.5.95.3 4.3.96.3 4.46 3..3 4.7 3.9.3 4.99 3.4.33 3.33.64.5 3.7.66.5 3.84.89.5 4.9.9.53 4. 3.3.53 4.47 3..54 4.73 3.3.54 5 3.33.64.49 3.7.66.5 3.84.89.5 4.9.9.5 4. 3.3.5 4.47 3..5 4.73 3.3.5 3.33.6.45 3.7.64.46 3.84.87.46 4.9.88.47 4. 3..47 4.47 3..47 4.7 3.3.48 5 3..59.55 3.59.6.56 3.7.83.56 3.95.84.57 4.8 3.7.57 4.3 3.6.58 4.57 3.6.58 4..99.9 4.68 3..3 4.84 3.7.3 5.6 3.8.33 5.3 3.54.34 5.64 3.53.35 5.95 3.76.37 5 4.3.9.44 4.49.93.46 4.64 3.8.47 4.95 3.9.48 5. 3.45.49 5.4 3.44.5 5.7 3.66.5 3 3.8.83.53 4.3.84.56 4.37 3.9.57 4.66 3..58 4.8 3.35.59 5.9 3.34.6 5.38 3.55.6 35 3.48.69.54 3.88.7.57 4..94.58 4.7.95.59 4.4 3.9.6 4.67 3.8.6 4.93 3.38.63 4.93.49.3 3.6.5.3 3.37.7.33 3.59.73.34 3.7.95.35 3.93.94.36 4.5 3.3.38 46.6.4..4.6.3.48.34.3.65.35.4.73.54.5.89.53.6 3.6.69.7 MODEL: AR G4LLTB AFR 3.3 Outdoor temperature Indoor temperature CDB 8 3 5 7 9 3 CWB 5 6 8 9 3 CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP - 4.6 3.3.36 4.5 3.5.36 4.68 3.54.36 4.99 3.55.37 5.4 3.83.37 5.45 3.8.37 5.76 4.6.38 3.97 3.9.4 4.4 3..43 4.57 3.49.43 4.87 3.5.43 5.3 3.78.44 5.33 3.76.44 5.63 4..44 5 3.84 3.5.53 4.8 3.7.54 4.43 3.44.54 4.7 3.45.54 4.87 3.73.55 5.6 3.7.55 5.45 3.96.56 3.7 3.9.63 4. 3..64 4.6 3.38.64 4.54 3.39.65 4.68 3.66.65 4.96 3.65.66 5.4 3.88.67 5 3.75 3..55 4.8 3.3.56 4.3 3.4.56 4.6 3.4.57 4.75 3.69.57 5.3 3.67.58 5.3 3.9.58 4.78 3.5. 5.3 3.54. 5.5 3.85. 5.87 3.86.4 6.5 4.7.4 6.4 4.5.6 6.78 4.4.7 5 4.56 3.44.35 5.8 3.46.37 5.5 3.76.38 5.6 3.77.39 5.77 4.7.4 6. 4.5.4 6.47 4.3.43 3 4.33 3.33.5 4.8 3.35.5 4.98 3.65.53 5.3 3.66.55 5.48 3.95.55 5.8 3.93.57 6.3 4.9.59 35 4.7 3.3.78 4.75 3.33.8 4.9 3.6.8 5.4 3.63.84 5.4 3.9.85 5.7 3.9.87 6.5 4.6.88 4 3..88.7 3.47.9.9 3.59 3.5.9 3.83 3.6.3 3.95 3.4.3 4.8 3.4.33 4.4 3.6.34 46...96.47..98.56.4.98.73.4.99.8.6..98.6. 3.5.77. MODEL: AR G8LLTB AFR 5.7 Outdoor temperature Indoor temperature CDB 8 3 5 7 9 3 CWB 5 6 8 9 3 CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP - 4.44 3.44.35 4.94 3.46.35 5. 3.77.35 5.45 3.78.36 5.6 4.8.36 5.96 4.6.36 6.9 4.33.37 4.34 3.4.4 4.83 3.4.4 5. 3.7.4 5.33 3.7.4 5.49 4..4 5.8 4..43 6.5 4.7.43 5 4. 3.33.5 4.68 3.35.5 4.84 3.64.5 5.6 3.65.53 5.3 3.94.53 5.64 3.93.54 5.96 4.9.54 4.4 3.5.6 4.5 3.7.63 4.66 3.56.63 4.96 3.57.63 5. 3.86.64 5.4 3.84.64 5.73 4.9.65 5 4. 3.8.54 4.56 3.3.54 4.7 3.59.55 5.3 3.6.55 5.9 3.89.56 5.5 3.87.56 5.8 4..57 5. 3.83.7 5.8 3.85.9 6. 4.9.9 6.4 4.. 6.6 4.54. 7. 4.5. 7.4 4.8.4 5 4.98 3.7.3 5.55 3.73.33 5.74 4.6.34 6. 4.7.35 6.3 4.4.36 6.69 4.38.38 7.6 4.66.39 3 4.73 3.58.46 5.7 3.6.48 5.45 3.9.49 5.8 3.93.5 5.98 4.5.5 6.34 4.3.53 6.7 4.5.55 35 4.66 3.55.74 5.9 3.57.76 5.37 3.88.77 5.7 3.9.79 5.9 4..8 6.5 4.9.8 6.6 4.46.84 4 3.4.96.4 3.8.98.5 3.9 3.4.6 4.8 3.5.7 4.3 3.5.8 4.57 3.5.9 4.83 3.7.3 46.43.4.94.7.44.95.79.65.96.98.66.97 3.7.87.97 3.5.86.98 3.44 3.5.99 AFR : Air Flow Rate (m 3 /min) TC : Total Capacity (kw) SHC : Sensible Heat Capacity (kw) IP : Input Power (kw)

- ( - ) - 66666HEATING CAPACITY This table is created using the maximum capacity. MODEL: AR GLLTB AFR.8 Outdoor temperature Indoor temperature CDB 6 8 4 CDB CWB TC IP TC IP TC IP TC IP TC IP -5-6 3.76.87 3.67.9 3.58.95 3.49.99 3.4.3 - - 4.6.87 4.6.9 4.6.95 3.96.99 3.86.3-5 -7 4.69.3 4.58.8 4.47. 4.35.6 4..6-5.3.7 5.7. 5.5.6 4.9.6 4.76.6 5 3 5.79.6 5.65. 5.5.6 5.38.6 5.8.6 7 6 5.99.6 5.85. 5.7.5 5.56.9 5.4.3 8 6.5.4 5.9.8 5.76. 5.6.6 5.47. 5 6.8. 5.93.5 5.79.9 5.64.4 5.5.8 5 5.87.78 5.73.8 5.59.85 5.45.89 5.3.9 4 8 5.86.76 5.7.79 5.58.83 5.44.87 5.3.9 MODEL: AR G4LLTB AFR 3.3 Outdoor temperature Indoor temperature CDB 6 8 4 CDB CWB TC IP TC IP TC IP TC IP TC IP -5-6 4.35.6 4.5. 4.4.5 4.4.3 3.94.34 - - 4.9.6 4.8. 4.68.5 4.56.3 4.45.34-5 -7 5.48.39 5.35.44 5..49 5.9.54 4.96.59-6.9.56 6.4.6 5.99.67 5.84.7 5.69.77 5 3 7.4.7 6.88.77 6.7.83 6.46.83 6.7.83 7 6 6.83.35 6.66.4 6.5.45 6.34.49 6.8.54 8 7.8.4 6.9.45 6.74.5 6.57.55 6.4.6 5 6.7.6 6.55. 6.39.4 6.3.9 6.7.3 5 6.8.64 6.3.67 5.98.7 5.83.74 5.68.78 4 8 6.47.64 6.3.68 6.6.7 6..75 5.85.78 MODEL: AR G8LLTB AFR 5.7 Outdoor temperature Indoor temperature CDB 6 8 4 CDB CWB TC IP TC IP TC IP TC IP TC IP -5-6 5.6.8 4.94. 4.8.7 4.69.3 4.57.36 - - 5.7.9 5.58.33 5.44.38 5.3.43 5.7.48-5 -7 6.37.4 6..46 6.6.5 5.9.56 5.76.6-7.5.58 7.8.63 6.9.68 6.73.74 6.56.79 5 3 8.3.7 7.93.77 7.74.83 7.55.83 7.35.83 7 6 7.87.36 7.69.4 7.5.46 7.3.5 7..56 8 8.6.4 7.97.46 7.77.5 7.58.57 7.39.6 5 7.75.7 7.56. 7.38.6 7.9. 7..4 5 7.4.65 7.7.68 6.9.7 6.73.75 6.55.79 4 8 7.46.65 7.9.69 7..7 6.93.76 6.75.79 AFR : Air Flow Rate (m 3 /min) TC : Total Capacity (kw) IP : Input Power (kw)

- ( - 3) - 777FAN PERFORMANCE 77777AIR VELOCITY DISTRIBUTIONS MODEL : AR GLLTB (UTD-GXSA-W) Note: This data is measured with the Auto louver grille kit(option) installed. zair velocity distribution Conditions Fan speed : High Operation mode : Fan (m) Unit: m/s Top view Vertical flap : Up Horizontal flap : Center.5 3 4 5 6 7 8 9 (m) (m) 5 Unit: m/s 4 3.5 Top view Vertical flap : Up Horizontal flap : Right & Left 3.5 4 5 3 4 5 6 7 8 9 (m) Side view Vertical flap : Up Horizontal flap : Center (m) 3.5.5 Unit: m/s 3 4 5 6 7 8 9 (m)

- ( - 4) - Note: This data is measured with the Auto louver grille kit(option) installed. zair velocity distribution Conditions Fan speed : High Operation mode : Heat Reference Data Side view Vertical flap : Down Horizontal flap : Center (m) 3.5 Unit: m/s.5 3 4 5 6 7 8 9 (m) zair temperature distribution Side view Vertical flap : Down Horizontal flap : Center (m) 3.5 Unit: C 3 8 6 4 3 4 5 6 7 8 9 (m)

- ( - 5) - MODEL : AR G4LLTB (UTD-GXSA-W) Note: This data is measured with the Auto louver grille kit(option) installed. zair velocity distribution Conditions Fan speed : High Operation mode : Fan (m) Unit: m/s Top view Vertical flap : Up Horizontal flap : Center.5 3 4 5 6 7 8 9 (m) (m) 5 Unit: m/s 4.5 3 Top view Vertical flap : Up Horizontal flap : Right & Left 3 4.5 5 3 4 5 6 7 8 9 (m) Side view Vertical flap : Up Horizontal flap : Center (m) 3.5.5 Unit: m/s 3 4 5 6 7 8 9 (m)

- ( - 6) - Note: This data is measured with the Auto louver grille kit(option) installed. zair velocity distribution Conditions Fan speed : High Operation mode : Heat Reference Data Side view Vertical flap : Down Horizontal flap : Center (m) 3.5 Unit: m/s.5 3 4 5 6 7 8 9 (m) zair temperature distribution Side view Vertical flap : Down Horizontal flap : Center (m) 3.5 Unit: C 3 8 6 4 3 4 5 6 7 8 9 (m)

- ( - 7) - MODEL : AR G8LLTB (UTD-GXSB-W) Note: This data is measured with the Auto louver grille kit(option) installed. zair velocity distribution Conditions Fan speed : High Operation mode : Fan (m) Unit: m/s Top view Vertical flap : Up Horizontal flap : Center.5 3 4 5 6 7 8 9 (m) (m) 5 Unit: m/s 4.5 3 Top view Vertical flap : Up Horizontal flap : Right & Left 3 4.5 5 3 4 5 6 7 8 9 (m) Side view Vertical flap : Up Horizontal flap : Center (m) 3.5.5 Unit: m/s 3 4 5 6 7 8 9 (m)

- ( - 8) - Note: This data is measured with the Auto louver grille kit(option) installed. zair velocity distribution Conditions Fan speed : High Operation mode : Heat Reference Data Side view Vertical flap : Down Horizontal flap : Center (m) 3.5 Unit: m/s.5 3 4 5 6 7 8 9 (m) zair temperature distribution Side view Vertical flap : Down Horizontal flap : Center (m) 3.5 Unit: C 3 8 6 4 3 4 5 6 7 8 9 (m)

- ( - 9) - 77777FAN PERFORMANCE CURVE MODEL : AR GLLTB External Static Pressure [Pa] 9 8 7 6 5 4 3 Quiet (SP mode9) Normal SP upper limit Quiet (Normal SP) SP mode upper limit SP mode9 upper limit Hi (SP mode9) SP mode9 lower limit Hi (Normal SP) Hi (SP mode) Quiet (SP mode) 3 4 5 6 7 8 Airflow [m 3 /h] Available airflow rate range (High level) * 9 External Static Pressure [Pa] 8 7 6 5 4 3 Hi (Normal SP) Hi (SP mode) Hi (SP mode) Hi (SP mode) Hi (SP mode9) Hi (SP mode8) Hi (SP mode7) Hi (SP mode6) Hi (SP mode5) Hi (SP mode4) Hi (SP mode3) 3 4 5 6 7 8 Airflow [m 3 /h] *: Available airflow rate range when Auto louver grille (option) is installed. Fan speed : High Vertical flap : Up

- ( - ) - Capacity (%) zcooling 8 6 4 Capacity 5 6 7 8 9 Airflow [m 3 /h] zheating Capacity (%) 8 6 4 Capacity 5 6 7 8 9 Airflow [m 3 /h]

- ( - ) - MODEL : AR G4LLTB SP mode9 upper limit Hi (SP mode9) External Static Pressure [Pa] 9 8 7 6 5 4 3 Quiet (SP mode9) Normal SP upper limit Quiet (Normal SP) SP mode upper limit Quiet (SP mode) 3 4 5 6 7 8 Airflow [m 3 /h] SP mode9 lower limit Hi (Normal SP) Hi (SP mode) 9 Available airflow rate range (High level) External Static Pressure [Pa] 9 8 7 6 5 4 3 Hi (SP mode4) Hi (SP mode3) Hi (Normal SP) Hi (SP mode) Hi (SP mode) Hi (SP mode) 3 4 5 6 7 8 Airflow [m 3 /h] *: Available airflow rate range when Auto louver grille (option) is installed. Fan speed : High Vertical flap : Up * Hi (SP mode9) Hi (SP mode8) Hi (SP mode7) Hi (SP mode6) Hi (SP mode5) 9

- ( - ) - Capacity (%) zcooling 8 6 4 Capacity 6 7 8 9 Airflow [m 3 /h] zheating Capacity (%) 8 6 4 Capacity 6 7 8 9 Airflow [m 3 /h]

- ( - 3) - MODEL : AR G8LLTB External Static Pressure [Pa] 9 8 7 6 5 4 3 SP mode9 upper limit Quiet (SP mode9) Normal SP upper limit Quiet (Normal SP) SP mode upper limit Quiet (SP mode) Hi (SP mode9) Hi (Normal SP) SP mode9 lower limit Hi (SP mode) 6 7 8 9 Airflow [m 3 /h] Available airflow rate range (High level) * External Static Pressure [Pa] 9 8 7 6 5 4 3 Hi (Normal SP) Hi (SP mode) Hi (SP mode) Hi (SP mode) Hi (SP mode9) Hi (SP mode8) Hi (SP mode7) Hi (SP mode6) Hi (SP mode5) Hi (SP mode4) Hi (SP mode3) 6 7 8 9 Airflow [m 3 /h] *: Available airflow rate range when Auto louver grille (option) is installed. Fan speed : High Vertical flap : Up

- ( - 4) - Capacity (%) zcooling 8 6 4 Capacity 7 8 9 Airflow [m 3 /h] zheating Capacity (%) 8 6 4 Capacity 7 8 9 Airflow [m 3 /h]

- ( - 5) - 77777AIRFLOW MODEL: AR GLLTB zcooling Fan speed Number of rotations (r.p.m.) Airflow m 3 /h 65 HIGH 34 MED 4 LOW 4 QUIET 3 l/s 8 CFM 383 m 3 /h 6 l/s 67 CFM 353 m 3 /h 55 l/s 53 CFM 34 m 3 /h 48 l/s 33 CFM 83 zheating Fan speed Number of rotations (r.p.m.) Airflow m 3 /h 65 HIGH 34 MED 4 LOW 4 QUIET 3 l/s 8 CFM 383 m 3 /h 6 l/s 67 CFM 353 m 3 /h 55 l/s 53 CFM 34 m 3 /h 48 l/s 33 CFM 83

- ( - 6) - MODEL: AR G4LLTB zcooling Fan speed Number of rotations (r.p.m.) Airflow m 3 /h 8 HIGH 56 MED 4 LOW 4 QUIET 3 l/s CFM 47 m 3 /h 7 l/s 94 CFM 4 m 3 /h 6 l/s 67 CFM 353 m 3 /h 48 l/s 33 CFM 83 zheating Fan speed Number of rotations (r.p.m.) Airflow m 3 /h 8 HIGH 56 MED 4 LOW 4 QUIET 3 l/s CFM 47 m 3 /h 7 l/s 94 CFM 4 m 3 /h 6 l/s 67 CFM 353 m 3 /h 48 l/s 33 CFM 83

- ( - 7) - MODEL: AR G8LLTB zcooling Fan speed Number of rotations (r.p.m.) Airflow m 3 /h 94 HIGH 38 MED 3 LOW QUIET 4 l/s 6 CFM 553 m 3 /h 88 l/s 44 CFM 58 m 3 /h 8 l/s 7 CFM 483 m 3 /h 75 l/s 8 CFM 44 zheating Fan speed Number of rotations (r.p.m.) Airflow m 3 /h 94 HIGH 38 MED 3 LOW QUIET 4 l/s 6 CFM 553 m 3 /h 88 l/s 44 CFM 58 m 3 /h 8 l/s 7 CFM 483 m 3 /h 75 l/s 8 CFM 44

- ( - 8) - 888OPERATION NOISE (SOUND PRESSURE) 88888NOISE LEVEL CURVE MODEL: AR GLLTB zcooling zheating 8 8 7 7 Octave band sound pressure level, db:(db=.µbar) 6 5 4 3 QUIET HIGH NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- NC-5 Octave band sound pressure level, db:(db=.µbar) 6 5 4 3 QUIET HIGH NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- NC-5 63 5 5 5,, 4, 8, Octave band center frequency,hz 63 5 5 5,, 4, 8, Octave band center frequency,hz MODEL: AR G4LLTB zcooling 8 zheating 8 7 7 Octave band sound pressure level, db:(db=.µbar) 6 5 4 3 QUIET HIGH NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- Octave band sound pressure level, db:(db=.µbar) 6 5 4 3 QUIET HIGH NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- NC-5 NC-5 63 5 5 5,, 4, 8, Octave band center frequency,hz 63 5 5 5,, 4, 8, Octave band center frequency,hz

- ( - 9) - MODEL: AR G8LLTB zcooling zheating 8 8 7 7 Octave band sound pressure level, db:(db=.µbar) 6 5 4 3 QUIET HIGH NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- Octave band sound pressure level, db:(db=.µbar) 6 5 4 3 QUIET HIGH NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- NC-5 NC-5 63 5 5 5,, 4, 8, Octave band center frequency,hz 63 5 5 5,, 4, 8, Octave band center frequency,hz

- ( - 3) - 88888SOUND LEVEL CHECK POINT m m Measuring duct Measuring duct.5m Microphone Microphone Center Front view Side view Center

- ( - 3) - 999ELECTRIC CHARACTERISTICS Model name AR GLLTB AR G4LLTB AR G8LLTB Voltage V 3 ~ Power supply Frequency Hz 5 Max. operating current A.44.64.55 Connection cable mm.5 *) Wiring Spec. Limited wiring length m 6 *) Wiring Spec. Selected Sample (Selected based on Japan Electrotechnical Standards and Codes Committee E5)

- ( - 3) - SAFETY DEVICES Protection form Model AR GLLTB AR G4LLTB AR G8LLTB Circuit protection Current fuse (PCB) 5V 3.5A Fan motor protection Over current protection.9 ±.4A Thermal protection program 38 ± 5 C OFF 5 ± 5 C ON

- ( - 33) - EXTERNAL INPUT & OUTPUT Connector INPUT OUTPUT REMARKS CN Control input CN3 Operation status output CN6 Fresh air control output CN Auxiliary heater output See external input/output settings for details. EXTERNAL INPUT CONTROL INPUT (Operation/Stop or Forced stop) The air conditioner can be remotely operated by means of the following on-site work. "Operation/Stop" mode or "Forced stop" mode can be selected with function setting of indoor unit. Unit operation is started at the following contents by adding the contact input of a commercial ON/OFF switch to a connector on the external control PC board and turning it ON. Unit operation Initial setting after power is ON Starting mode other than initial setting Operation mode Auto changeover Mode at previous operation Set temperature 4 C Temperature at previous operation Air flow mode AUTO Mode at previous operation Up-down air direction (swing) Standard air direction (swing OFF) Air direction at previous operation Left-right air direction (swing) Standard air direction (swing OFF) Air direction at previous operation zcircuit diagram example Indoor unit control PC board Connected unit Connector 3 * m Ex.) Switch Contact capacity : 4VDC or more, ma or more. Please use non-polar relays and switches. Signal Field supply * Make the distance from the PC board to the connected unit within m. When function setting is in "Operation/Stop" mode Input signal ON OFF Indoor unit Operation Stop When function setting is in "Forced stop" mode Input signal ON OFF Command Forced stop Normal Indoor unit Operation Stop Remote controller ON ON ON zparts (Optional) Model name UTD-ECS5A Wire (External input) Remote control operation invalidity

- ( - 34) - EXTERNAL OUTPUT OPERATION STATUS OUTPUT An air conditioner operation status signal can be output. zcircuit diagram example Indoor unit control PC board Connected unit Connector 4V DC V Ex.)Relay unit Ex.)Display Relay power supply * m Signal Field supply * Make the distance from the PC board to the connected unit within m. Relay spec. : Max.4VDC, ma to less than 5mA. Indoor unit Output signal Operation Stop ON OFF zparts (Optional) Model name UTD-ECS5A Wire (External output)

- ( - 35) - FRESH AIR CONTROL OUTPUT A signal linked to air conditioner indoor fan ON can be output. * However, signal becomes OFF during cold air prevention control operation. zcircuit diagram example Indoor unit control PC board V on/off Connector Ex.) Relay unit Connected unit Ex.) Fan Relay power supply * m Signal Field supply * Make the distance from the PC board to the connected unit within m. Relay spec. : Rated VDC, 5mA or less. Indoor fan Output signal Operation Stop ON OFF zparts (Optional) Model name UTD-ECS5A Wire (Fresh air output)

- ( - 36) - AUXILIARY HEATER OUTPUT A signal is outputed from Connector when indoor fan and compressor is turned on under heating operation. * Signal output performance specifications are as OFF Tr-Ts = - C shown on the right Ex. When Set Temperature(Ts) is C; ON and Room Temperature(Tr) increase above C, Tr-Ts = - C signal output is on. and Room Temperature(Tr) increase above C, OFF signal output is off. and Room Temperature(Tr) decrease below 9 C, signal output is on. and Room Temperature(Tr) decrease below C, signal output is off. zjumper wire (Indoor Unit) This is used to continue indoor unit fan operation for minute after thermo OFF in heating mode. minute delay control set by cutting jumper wire on PCB. zcircuit diagram example Indoor unit control PC board Connected unit V on/off Connector * m Ex.) Relay unit Ex.) Heater Relay power supply Tr-Ts Tr-Ts = -3 C Tr-Ts = - C Signal Field supply * Make the distance from the PC board to the connected unit within m. Relay spec. : Rated VDC, 5mA or less. Heating operation Operation Stop Indoor unit fan Output signal ON OFF ON OFF min! CAUTION Please place an external heater between the indoor unit and the outlet. Please be sure to use delay control of the fan. Supply air External Heater Indoor unit Return air zparts (Optional) Model name UTD-ECS5A Wire (Heater output)

- ( - 37) - FUNCTION SETTINGS INDOOR UNIT INDOOR UNIT DIP SW 3 4 Remote controller address setting JM Drainage function setting Jumper Wire JM Auto louver grille setting JM3 Fan delay setting SWITCH POSITION DIP-SW SETTING zremote controller address setting A number of indoor units can be operated at the same time using a wired remote controller. Set the unit number of each indoor unit using the DIP switches on the indoor unit circuit board. (See the following table.) The DIP switches are normally set to make the unit number. (...Factory setting) Remote controller address DIP switch No. 3 4 OFF OFF OFF OFF ON OFF OFF OFF OFF ON OFF OFF 3 ON ON OFF OFF 4 OFF OFF ON OFF 5 ON OFF ON OFF 6 OFF ON ON OFF 7 ON ON ON OFF 8 OFF OFF OFF ON 9 ON OFF OFF ON OFF ON OFF ON ON ON OFF ON OFF OFF ON ON 3 ON OFF ON ON 4 OFF ON ON ON 5 ON ON ON ON

- ( - 38) - JUMPER WIRE SETTING zdrainage function setting (JM) (u...factory setting) JM Drainage function u Connect Valid Disconnect Invalid zauto louver grille setting (JM) When Auto louver grille kit (optional parts) is attached, set the Auto louver grille setting to "Valid". (u...factory setting) JM Auto louver grille setting u Connect Invalid Disconnect Valid zfan delay setting (JM3) (u...factory setting) JM3 Fan delay u Connect Invalid Disconnect Valid

- ( - 39) - INDOOR UNIT (Setting by remote controller) The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit to malfunction. After the power is turned on, perform the Function Setting according to the installation conditions using the remote controller. The settings may be selected between the following two: Function Number or Setting Value. Settings will not be changed if invalid numbers or setting values are selected. PREPARATION Turn on the power. * Before turning on the power of the indoor units, make sure the piping air-tight test and vacuuming have been conducted. * Also check again to make sure no wiring mistakes were made before turning on the power. FUNCTION SETTING METHOD (for Wired remote controller) zsetting method () Press the SET TEMP. buttons ( ) ( ) and FAN button simultaneously for more than 5 seconds to enter the function setting mode. SU MO TU WE TH FR SA ) Press the SET BACK button to select the indoor unit number. SET BACK SU MO TU WE TH FR SA Unit number of INDOOR UNIT 3) Press the Set time buttons to select the function number. SU MO TU WE TH FR SA Function number (4) Press the SET TEMP. buttons ( ) ( ) to select the setting value. The display flashes during setting value selection. SU MO TU WE TH FR SA Setting value

- ( - 4) - (5) Press the TIMER SET button to confirm the setting. Press the TIMER SET button for a few seconds until the setting value stops flashing. If the setting value display changes or if - - is displayed when the flashing stops, the setting value has not been set correctly. (An invalid setting value may have been selected for the indoor unit.) (6) Repeat steps to 5 to perform additional settings. Press the SET TEMP. buttons ( ) ( ) and FAN button simultaneously again for more than 5 seconds to cancel the function setting mode. In addition, the function setting mode will be automatically canceled after minute if no operation is performed. (7) After completing the Function Setting, be sure to turn off the power and turn it on again.! CAUTION After turning off the power, wait 3 seconds or more before turning on it again. The Function Setting will not become active unless the power is turned off then on again.

CONTENTS OF FUNCTION SETTING Follow the instructions in the Local Setup Procedure, which is supplied with the remote control, in accordance with the installed condition. After the power is turned on, perform the Function Setting on the remote control. The settings may be selected between the following two: Function Number or Setting Value. Settings will not be changed if invalid numbers or setting values are selected. ) Filter sign ) Static pressure 3) Cooler room temperature correction 4) Heater room temperature correction 5) Auto restart 6) Indoor room temperature sensor switching function 7) Remote controller signal code 8) External input control 9) Indoor unit fan control for energy saving ) Filter sign The indoor unit has a sign to inform the user that it is time to clean the filter. Select the time setting for the filter sign display interval in the table below according to the amount of dust or debris in the room. If you do not wish the filter sign to be displayed, select the setting value for "No indication". (... Factory setting) Setting description Function number Setting value Standard (4 hours) Long interval ( hours) Short interval ( hours) No indication 3 ) Static pressure Select appropriate static pressure according to the installation conditions. (... Factory setting) Setting description Function number Setting value Pa Pa Pa 3 Pa 3 4 Pa 4 5 Pa 6 5 6 Pa 6 7 Pa 7 8 Pa 8 9 Pa 9 5 Pa [Standard] 3 3) Cooler room temperature correction Depending on the installed environment, the room temperature sensor may require a correction. The settings may be selected as shown in the table below. (... Factory setting) Setting description Function number Setting value Standard Slightly lower control 3 Lower control Warmer control 3 When using floor console installation, change the setting value to "". - ( - 4) -

- ( - 4) - 4) Heater room temperature correction Depending on the installed environment, the room temperature sensor may require a correction. The settings may be changed as shown in the table below. (... Factory setting) Setting description Function number Setting value Standard Lower control 3 Slightly warmer control Warmer control 3 When using floor console installation, change the setting value to "". 5) Auto restart Enable or disable automatic system restart after a power outage. (... Factory setting) Setting description Function number Setting value Yes 4 No * Auto restart is an emergency function such as for power failure etc. Do not start and stop the indoor unit by this function in normal operation. Be sure to operate by the control unit, or external input device. 6) Indoor room temperature sensor switching function (Only for Wired remote controller) The following settings are needed when use the control by Wired remote controller temperature sensor. (... Factory setting) Setting description Function number Setting value No 4 Yes * If setting value is : Room temperature is controlled by the indoor unit temperature sensor. * If setting value is : Room temperature is controlled by either indoor unit temperature sensor or remote controller unit sensor. 7) Remote controller signal code Change the indoor unit Signal Code, depending on the remote controllers. (... Factory setting) Setting description Function number Setting value A B 44 C D 3 8) External input control "Operation/Stop" mode or "Forced stop" mode can be selected. (... Factory setting) Setting description Function number Setting value Operation/Stop mode (Setting forbidden) 46 Forced stop mode

- ( - 43) - 9) Indoor unit fan control for energy saving (Only cooling mode) Enable or disable indoor unit fan control when the outdoor unit is stopped. (... Factory setting) Setting description Function number Setting value No 49 Yes * If setting value is "": When the outdoor unit is stopped, the indoor unit fan operates following the setting on the remote controller continuously. * If setting value is "": When the outdoor unit is stopped, the indoor unit fan operates at very low speed intermittently.

- ( - 44) - WIRED REMOTE CONTROLLER SWITCH POSITION Front case (back side) OFF 3 4 5 6 ON DIP Switch DIP Switch (All switches fixed at OFF) ON DIP SWITCH SETTING DIP Switch SW Forbidden* SW Dual remote controller setting SW3 Forbidden* SW4 Forbidden* SW5 Forbidden* SW6 Memory backup setting *Switches are fixed at OFF.. Dual remote controller setting Set the remote controller on SW according to the following table. ( Factory setting) Number of remote controller Primary unit SW Secondary unit SW (Normal) OFF (Dual) OFF ON. Memory backup setting Set to ON to use batteries for the memory backup. If batteries are not used, all of the settings stored in memory will be deleted if there is a power failure. ( Factory setting) SW6 Memory backup OFF Invalidity ON Validity

- ( - 45) - OPTIONAL PARTS CONTROLLER Exterior Parts name Model No. Summary Wired remote controller UTY-RVN M Large and full-dot liquid crystal screen, wide and large keys easy to press, user-intuitive arrow key. Wired remote controller UTY-RNN M The room temperature can be controlled by detecting the temperature accurately with built-in thermo sensor. Simple remote controller UTY-RSN M Compact remote controller concentrates on the basic functions such as Start/ Stop, Fan Control, Temperature Setting and Operation mode. IR receiver unit UTY - LRH M Unit control is performed by wireless remote controller. OTHERS Exterior Parts name Model No. Summary ( x ) ( x ) ( x ) ( x ) External control set UTD-ECS5A Use to connect with various peripheral devices and air conditioner PC board. (Set of 6) Remote sensor unit UTY-XSZX New amenity space can be offered by installing the Remote sensor in the remote controller. Auto louver grille kit UTD-GXSA-W (*) UTD-GXSB-W (*) *: For, 4 models *: For 8 model

. SINGLE TYPE : AO GLALL AO G4LALL AO G8LALL AO G4LALA DTR_AO99E_ 3..8

CONTENTS AO G-4LAL.. SPECIFICATIONS... -. DIMENSIONS... - AO G-4LAL 3. REFRIGERANT CIRCUIT... - 3 4. WIRING DIAGRAMS... - 4 5. CAPACITY COMPENSATION RATE FOR PIPE LENGTH AND HEIGHT DIFFERENCE... - 6 6. ADDITIONAL CHARGE CALCULATION... - 7. AIRFLOW... - 8. OPERATION NOISE (SOUND PRESSURE)... - 3 8-. NOISE LEVEL CURVE... - 3 8-. SOUND LEVEL CHECK POINT... - 5 9. ELECTRIC CHARACTERISTICS... - 6. SAFETY DEVICES... - 7

- ( - ) - SPECIFICATIONS AO G-4LAL Type INVERTER HEAT PUMP Model name AO GLALL AO G4LALL AO G8LALL AO G4LALA Power source 3V ~ 5Hz Available voltage range 98-64V ~ 5Hz Starting current A 5. 6. 7.4 9.9 Cooling 78 9 47 Airflow rate m 3 /h Heating 63 74 9 47 Fan Type Q'ty Propeller Motor output W 54 65 Sound pressure level Cooling 47 49 5 5 db (A) Heating 48 49 5 53 Sound power level Cooling 6 6 6 67 db (A) Heating 63 64 65 7 Dimensions (H W D) mm 546 876 8. 546 84 8. 546 866 8. 546 83 8. 54 589 8. Fin pitch.3.4 Heat exchanger type 6 Rows Stages 6 4 Pipe type Copper Fin Type Aluminium Compressor Type Q'ty Twin Rotary Motor output W Type Refrigerant (Global Warming Potential) R4A(975) Charge g 5 5 7 Refrigerant oil Type POE Material Steel sheet Enclosure Beige Colour Approximate colour of MUNSELL YR7.5/. Dimensions Net 578 79 3 578 79 35 mm (H W D) Gross 648 9 38 Weight Net 4 44 kg Gross 44 48 Size Liquid Ø6.35 (Ø/4 in.) mm Gas Ø9.5 (Ø3/8 in.) Ø.7 (Ø/ in.) Ø5.88 (Ø5/8 in.) Connenction pipe Method Flare Pre-charge length 5 Max. length m 5 3 Max. height difference 5 Operation range Cooling - to 46 C Heating -5 to 4 Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 7 CDB / 9 CWB.and outdoor temperature of 35 CDB / 4 CWB. Heating : Indoor temperature of CDB / 5 CWB.and outdoor temperature of 7 CDB / 6 CWB. Pipe length : 5. m, Height difference : m. (Outdoor unit - Indoor unit) The protective function may work when using it outside the operation range. AO G-4LAL

- ( - ) - DIMENSIONS MODEL: AO GLALL, AO G4LALL, AO G8LALL, AO G4LALA (Unit : mm) AO G-4LAL Top view AO G-4LAL Front view Air flow AO GLALL AO G4LALA AO G4LALL AO G8LALL Side view Bottom view INSTALLATION PLACE When there are obstacles at the back or front sides. When there are obstacles at the back, side(s), and top. 6 mm or more When there are obstacles at the back, side with the installation of more than one unit. 6 mm or more mm or more mm or more 3 mm or more (Service space) 3 mm or more 3 mm or more 3 mm or more 3 mm or more

- ( - 3) - 333REFRIGERANT CIRCUIT MODEL: AO GLALL, AO G4LALL, AO G8LALL, AO G4LALA AO G-4LAL AO G-4LAL Refrigerant pipe diameter Liquid : /4" (6.35 mm) Gas : 3/8" (9.5 mm) : AO GLALL /" (.7 mm) : AO G4LALL, AO G8LALL 5/8" (5.88 mm) : AO G4LALA

- ( - 4) - 444WIRING DIAGRAMS MODEL: AO GLALL, AO G4LALL, AO G8LALL AO G-4LAL AO G-4LAL

- ( - 5) - MODEL: AO G4LALA AO G-4LAL AO G-4LAL

- ( - 6) - CAPACITY COMPENSATION RATE FOR PIPE LENGTH 555 AND HEIGHT DIFFERENCE AO G-4LAL This table is created using the maximum capacity. MODEL: AO GLALL Height difference H (m) COOLING Û Indoor unit is higher than outdoor unit. Û Indoor unit is lower than outdoor unit. Pipe length (m) 5 7.5 5 5 5 - - -.93.894.867 - -.964.98.99.88 7.5 -.988.968.9.9.885 5.99.99.97.95.96.888...98.933.93.895-5...98.933.93.895-7.5 -..98.933.93.895 - - -.98.933.93.895-5 - - -.933.93.895 AO G-4LAL Height difference H (m) HEATING Û Indoor unit is higher than outdoor unit. Û Indoor unit is lower than outdoor unit. Pipe length (m) 5 7.5 5 5 5 - - -.943.96.896 - -..943.96.896 7.5 -...943.96.896 5....943.96.896....943.96.896-5.995.995.5.939.9.89-7.5 -.993..936.99.89 - - -.999.934.97.887-5 - - -.95.898.878 Height difference H Indoor unit Outdoor unit H Outdoor unit H Indoor unit Connection pipe Indoor unit is higher than outdoor unit. Connection pipe Indoor unit is lower than outdoor unit.

- ( - 7) - AO G-4LAL This table is created using the maximum capacity. MODEL: AO G4LALL Height difference H (m) COOLING Û Indoor unit is higher than outdoor unit. Û Indoor unit is lower than outdoor unit. Pipe length (m) 5 7.5 5 5 5 - - -.953.95.947 - -.983.968.966.96 7.5 -.988.987.97.97.966 5.99.99.99.976.974.97...999.984.98.978-5...999.984.98.978-7.5 -..999.984.98.978 - - -.999.984.98.978-5 - - -.984.98.978 AO G-4LAL Height difference H (m) HEATING Û Indoor unit is higher than outdoor unit. Û Indoor unit is lower than outdoor unit. Pipe length (m) 5 7.5 5 5 5 - - -.98.89.86 - -.98.98.89.86 7.5 -..98.98.89.86 5...98.98.89.86...98.98.89.86-5.995.995.976.94.886.858-7.5 -.993.974.9.884.856 - - -.97.99.88.854-5 - - -.9.873.845 Height difference H Indoor unit Outdoor unit H Outdoor unit H Indoor unit Connection pipe Indoor unit is higher than outdoor unit. Connection pipe Indoor unit is lower than outdoor unit.

- ( - 8) - AO G-4LAL This table is created using the maximum capacity. MODEL: AO G8LALL Height difference H (m) COOLING Û Indoor unit is higher than outdoor unit. Û Indoor unit is lower than outdoor unit. Pipe length (m) 5 7.5 5 5 5 - - -.953.95.947 - -.983.968.966.96 7.5 -.988.987.97.97.966 5.99.99.99.976.974.97...999.984.98.978-5...999.984.98.978-7.5 -..999.984.98.978 - - -.999.984.98.978-5 - - -.984.98.978 AO G-4LAL Height difference H (m) HEATING Û Indoor unit is higher than outdoor unit. Û Indoor unit is lower than outdoor unit. Pipe length (m) 5 7.5 5 5 5 - - -.9.894.867 - -.98.9.894.867 7.5 -..98.9.894.867 5...98.9.894.867...98.9.894.867-5.995.995.977.96.889.86-7.5 -.993.975.93.887.86 - - -.97.9.885.858-5 - - -.9.876.849 Height difference H Indoor unit Outdoor unit H Outdoor unit H Indoor unit Connection pipe Indoor unit is higher than outdoor unit. Connection pipe Indoor unit is lower than outdoor unit.

- ( - 9) - AO G-4LAL This table is created using the maximum capacity. MODEL: AO G4LALA Height difference H (m) COOLING Û Indoor unit is higher than outdoor unit. Û Indoor unit is lower than outdoor unit. Pipe length (m) 5 7.5 5 5 3 - - - -.963.96.959 - -.984.98.979.977.975 7.5 -.988.988.985.983.98.979 5.99.99.99.989.987.985.983....997.995.993.99-5....997.995.993.99-7.5 -...997.995.993.99 - - -..997.995.993.99 - - - - -.995.993.99 AO G-4LAL Height difference H (m) HEATING Û Indoor unit is higher than outdoor unit. Û Indoor unit is lower than outdoor unit. Pipe length (m) 5 7.5 5 5 3 - - - -.97.893.863 - -.99.95.97.893.863 7.5 -..99.95.97.893.863 5...99.95.97.893.863...99.95.97.893.863-5.995.995.987.947.9.888.859-7.5 -.993.984.945.9.886.857 - - -.98.943.97.884.855 - - - - -.98.875.846 Height difference H Indoor unit Outdoor unit H Outdoor unit H Indoor unit Connection pipe Indoor unit is higher than outdoor unit. Connection pipe Indoor unit is lower than outdoor unit.

- ( - ) - 666ADDITIONAL CHARGE CALCULATION MODEL: AO GLALL Refrigerant type R4A AO G-4LAL Refrigerant amount g 5 zrefrigerant charge Total pipe length m 5 or less 5 (MAX) Additional charge g g/m AO G-4LAL MODEL: AO G4LALL, AO G8LALL Refrigerant type R4A Refrigerant amount g 5 zrefrigerant charge Total pipe length m 5 or less 5 (MAX) Additional charge g g/m MODEL: AO G4LALA Refrigerant type R4A Refrigerant amount g 7 zrefrigerant charge Total pipe length m 5 or less 5 3 (MAX) Additional charge g 3 g/m

- ( - ) - 777AIRFLOW MODEL: AO GLALL zcooling AO G-4LAL Number of rotations (r.p.m.) 77 Airflow m 3 /h 78 l/s 494 AO G-4LAL CFM 48 zheating Number of rotations (r.p.m.) Airflow m 3 /h 63 7 l/s 453 CFM 959 MODEL: AO G4LALL zcooling Number of rotations (r.p.m.) Airflow m 3 /h 9 8 l/s 53 CFM 4 zheating Number of rotations (r.p.m.) Airflow m 3 /h 74 75 l/s 483 CFM 4

- ( - ) - MODEL: AO G8LALL zcooling AO G-4LAL Number of rotations (r.p.m.) 86 Airflow m 3 /h l/s 556 AO G-4LAL CFM 77 zheating Number of rotations (r.p.m.) Airflow m 3 /h 9 8 l/s 53 CFM 4 MODEL: AO G4LALA zcooling Number of rotations (r.p.m.) Airflow m 3 /h 47 5 l/s 686 CFM 454 zheating Number of rotations (r.p.m.) Airflow m 3 /h 47 5 l/s 686 CFM 454

- ( - 3) - 888OPERATION NOISE (SOUND PRESSURE) 88888NOISE LEVEL CURVE MODEL: AO GLALL AO G-4LAL Octave band sound pressure level, db:(db=.µbar) zcooling 8 7 6 5 4 3 NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- Octave band sound pressure level, db:(db=.µbar) zheating 8 7 6 5 4 3 NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- AO G-4LAL NC-5 NC-5 63 5 5 5,, 4, 8, Octave band center frequency,hz 63 5 5 5,, 4, 8, Octave band center frequency,hz MODEL: AO G4LALL zcooling 8 zheating 8 7 7 Octave band sound pressure level, db:(db=.µbar) 6 5 4 3 NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- Octave band sound pressure level, db:(db=.µbar) 6 5 4 3 NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- NC-5 NC-5 63 5 5 5,, 4, 8, Octave band center frequency,hz 63 5 5 5,, 4, 8, Octave band center frequency,hz

- ( - 4) - MODEL: AO G8LALL AO G-4LAL Octave band sound pressure level, db:(db=.µbar) zcooling 8 7 6 5 4 3 NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- Octave band sound pressure level, db:(db=.µbar) zheating 8 7 6 5 4 3 NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- AO G-4LAL NC-5 NC-5 63 5 5 5,, 4, 8, Octave band center frequency,hz 63 5 5 5,, 4, 8, Octave band center frequency,hz MODEL: AO G4LALA zcooling 8 zheating 8 7 7 Octave band sound pressure level, db:(db=.µbar) 6 5 4 3 NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- Octave band sound pressure level, db:(db=.µbar) 6 5 4 3 NC-65 NC-6 NC-55 NC-5 NC-45 NC-4 NC-35 NC-3 NC-5 NC- NC-5 NC-5 63 5 5 5,, 4, 8, Octave band center frequency,hz 63 5 5 5,, 4, 8, Octave band center frequency,hz

- ( - 5) - 88888SOUND LEVEL CHECK POINT AO G-4LAL Airflow AO G-4LAL

- ( - 6) - 999ELECTRIC CHARACTERISTICS AO G-4LAL Model name AO GLALL AO G4LALL AO G8LALL AO G4LALA Power supply Voltage V 3 ~ Frequency Hz 5 *) Max operating current A..5 3.5 Starting Current A 5. 6. 7.4 9.9 Main Fuse (Circuit breaker) *) Wiring Spec. Current A 5 Power Cable mm 4. AO G-4LAL *) The maximum current is the total current of indoor unit and outdoor unit. *) Wiring Spec.: Selected Sample (Selected based on Japan Electrotechnical Standards and Codes Committee E5)

- ( - 7) - SAFETY DEVICES AO G-4LAL Circuit protection Protection form Current fuse (Near the terminal) Current fuse (Main printed circuit board) Model AO GLALL AO G4LALL AO G8LALL AO G4LALA 5V A 5V 5A 5V 5A 5V 3.5A AO G-4LAL Fan motor protection Thermal protection program OFF : +5 - C ON : 95 +5 - C OFF : +5 - C ON : 5 +5 - C Compressor protection Terminal protection program (Compressor temp.) Thermal protection program (Discharge temp.) OFF : C ON : After 4 minutes and 8 C or less OFF : C ON : After 7 minutes