SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

Similar documents
SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

MODELS K2EU060A, K4EU090A, & K3EU120A

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 60 HZ MODELS: EF-10 & FF-10

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

INSTALLATION MANUAL (AIR COOLED) SPLIT-SYSTEM AIR CONDITIONER MODEL: LA120 NOTES, CAUTIONS AND WARNINGS SAVE THIS MANUAL B-0203

C13-Series Engineering Guide

VertiCool Aurora Engineering Guide

SPLIT-SYSTEM EVAPORATOR BLOWER (AIR COOLED) INSTALLATION INSTRUCTION Supersedes: Nothing N4C-0500

INSTALLATION INSTRUCTION

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

MODELS B1PA024, 030 AND 036

ACCESSORY INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY 10, 16, 26, 36 & 72

TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM HEAT PUMP FOUR PIPE SYSTEM DESCRIPTION E*FB180 & 240 F*EH180 & & 20 NOMINAL TONS INDOOR UNIT

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ACCESSORY KIT INSTALLATION INSTRUCTIONS

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

COMMERCIAL AIR HANDLER

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

ACCESSORY KIT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION-50 Hz

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

COMMERCIAL AIR HANDLER

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

INSTALLATION INSTRUCTION

Models PF1A PF1B PACKAGED AIR-HANDLING UNITS. 6to10Tons. Form No. PDS PF1A.72.1 FEATURES/BENEFITS

MODELS B3CH 048 AND 060 (WORLD 50 HZ)

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

technical guide Water-Cooled Self-Contained Units

Product Data FEATURES/BENEFITS. 524J PACKAGED AIR -HANDLING UNITS WITH PURONr REFRIGERANT SIZES 07, 08, 12, 14, 16. Indoor air quality features

INSTALLATION INSTRUCTION

SUNLINE 2000 ELECTRIC / ELECTRIC SINGLE PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTION Supersedes: N7Y (993) 530.

BAC / BHC SERIES 7-1/2 to 20 Ton Air Handlers

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Product Data. 40RUA/40RUS 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units FEATURES/BENEFITS. Indoor air quality features

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

SUNLINE 2000 SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS DESCRIPTION FEATURES

VariCool VAV Engineering Guide

Advance Release September 2009

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

Product Data FEATURES/BENEFITS 524J***H 6 TO 20 TON DIRECT EXPANSION PACKAGED HEAT PUMP AIR -HANDLING UNIT. Indoor air quality features 524J-H 07-12

SKYPAK II, 3 Ton Series, gives you a

KIC Air Curtains. Technical Guide

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

KAP Horizontal Product Coolers

SKYPAK II, 3 Ton Series, gives you a

Split System Heat Pumps

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CoolSpot Engineering Guide

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

40 RM/RMS Packaged Air-Handling Units

CWA4 Chilled & Hot Water Fan Coil

DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil

PACKAGE AIR CONDITIONER

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

Water-Cooled Self-Contained Units

GENERAL ELECTRIC AIR HANDLING UNITS DIRECT EXPANSION. ABQ Series ABQ03 thru ABQ TR thru 30 TR 9 kw thru 105 kw

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

INSTALLATION INSTRUCTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

FCC Fan-Coil Units High-Performance, Vertical

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

SUNLINE SERIES SINGLE PACKAGE AIR CONDITIONERS. INSTALLATION INSTRUCTION Supersedes: Nothing N3Y (394) MODELS D*SC360 & 480 INSPECTION

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

FILTERS MANIFOLD CABINET REFRIGERANT CONNECTION LOCATION

INSTALLATION INSTRUCTION

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Supersedes: N2Y (498) N2Y (799) MODELS B1HH018 THRU THRU 5 TON (12 SEER)

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

Q-TEC QC-Series Chilled Water Air Conditioner

Transcription:

(994) SPLIT-SYSTEM EVAPORATOR BLOWER K5EU090 and K4EU120 50 Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX coil with copper tubes and aluminum fins, an expansion valve, a distributor, throwaway filters, a centrifugal blower, a blower motor, an adjustable belt drive, a blower motor contactor and a small holding charge of refrigerant-22. The units are manufactured under ISO 9002 Quality System Certification. The units are shipped in the vertical position ready for field installation. They can be installed for horizontal operation by reversing the position of the solid bottom panel with the return air duct flange on the front on the unit. ACCESSORIES - FIELD INSTALLED SUPPLY AIR PLENUMS - Fully insulated plenums are available for free standing units located within the conditioned space, are shipped knocked down for easy field assembly, are finished to match the exterior of the basic unit, and have double deflection grilles that can be adjusted to vary the throw, spread and drop of the supply air. RETURN AIR GRILLES - Expanded metal grilles are available for free standing units located within the conditioned space. Grilles are finished to match the exterior of the basic unit and are shipped in one piece for easy installation. BASES - Bases are available to raise vertical units above the floor. Outdoor air may be introduced through these bases by cutting an access opening to accommodate the outdoor air duct connection. These bases are finished to match the exterior of the basic unit. They may have to be insulated in the field for certain applications. THREE-PHASE ELECTRIC HEATERS - Electric heaters are available in four capacities to provide maximum flexibility. Both the air conditioning unit and the heater can be selected to precisely match the cooling and heating requirements of the conditioned space. These heaters are designed for easy fieldinstallation over the supply air opening of the unit. Every heater is fully protected against excessive current and temperature by fuses and two high limit thermostats. Units with electric heat require only one power supply for both the heating elements and the supply air blower motor. The power wiring can be protected by either dual element/time delay fuses or an inverse time circuit breaker. HOT WATER COILS _ Drainable coils have two rows of 13mm ( 1 2") copper tubes, eight aluminum fins per 25mm (1in.), a casing that is finished to match the exterior of the basic unit, but no water control valve. The coils slide out of their casings for easy field installation. They should be mounted over the return air opening. STEAM COILS - Non-freeze coils have one row of 25mm (1in.) copper tubes, a 16mm ( 5 8") copper tube inside each 25mm (1in.) tube to distribute the steam evenly across the entire length of the coil, eight aluminum fins per 25mm (1in,), a casing finished to match the exterior of the basic unit, but no steam control valve. The coils slide out or their casings for easy field installation and are pitched in their casings to facilitate condensate drainage. They should be mounted over the return air opening. SUSPENSION KIT - Suspension kit 1HH0451 is available for units installed horizontally. The accessory includes two channel iron supports and the hardware to secure them to the top of the unit. The hanger rods must be supplied by the field. THERMOSTATS - Wall-mounted thermostats and sub-bases (24volt) with system and fan switches are available to control the operation of these split system air conditioners.

These units are built in a single cabinet with two condensate drain pans. This allows the units to be installed in either the vertical or horizontal position for maximun flexibility. On vertical applications, the air velocity across the cooling coil keeps the condensate from dripping off the finned surface onto the filters. On horizontal applications, the unit must be installed with the condensate drain pan under the entire cooling coil. The Supply Air Plenum and the Return Air Grille accessories can be used on either arrangement. The Base accessory can only be used on the vertical arrangement. Units installed horizontally are designed for ceiling suspension. Four 9.5mm ( 3 8"-16) weldnuts are provided in the angle supports on the front of the unit (the side with the logo). Knockouts are provided in the exterior panels for access to these weldnuts. The hanger rods must be supplied in the field. APPLICATION FLEXIBILITY HEATING CAPACITY - ELECTRIC HEAT ACCESSORY Ratings 1 Capacity 1 Heater Model UL Test Voltage (@415V) Per Stage 1 Per Stage 2 kw Mbh kw Mbh kw Mbh 2HSO4501050 415 7.5 25.6 7.5 25.6 - - 2HSO4501650 415 12.0 40.9 7.5 25.6 4.5 15.3 2HSO4502650 415 19.4 66.5 12.0 40.9 7.5 25.6 2HSO4503650 415 26.9 91.6 12.0 40.9 15.0 51.1 1 Capacity ratings do not include the heat generated by the supply air blower motor. 2 For 380 volts, multiply the Mbh and kw values by (380/415) 2 or 0.838. 2 Unitary Products Group

STEAM COIL CAPACITY 1, kw @ 14 kpa / Mbh @ 2 psig 2 Steam Coil Model Blower Model Used On m 3 /s / cfm Dry Bulb Temperature of Air Entering Coil, C/ F -12 / 10-1 / 30 10 / 50 21 / 70 1.1 / 2400 172.2 / 588 155.5 / 531 139.1 / 475 122.4 / 418 KEU090 1.4 / 3000 191.2 / 653 172.6 / 589 154.3 / 527 136.0 / 464 1NF0451 1.7 / 3600 207.5 / 708 187.1 / 640 167.4 / 572 147.4 / 503 1.5 / 3200 196.4 / 671 177.6 / 606 158.8 / 542 140.0 / 478 KEU120 1.9 / 4000 217.3 / 742 196.3 / 670 175.3 / 598 154.8 / 528 2.3 / 4800 236.1 / 806 212.9 / 727 190.4 / 650 167.8 / 573 1 These capacities do not include any blower motor heat. 2 Multiple these capacities by the following factors to correct for higher steam pressure. Steam pressure, kpa/psig 35 / 5 70 / 10 105 / 15 140 / 20 175 / 25 Capacity correction factor 1.06 1.12 1.19 1.25 1.30 NOTE: Steam rate kg/hr = 0.66 x kw (lbs/hr) = 1.025 x Mbh. CAUTION: Do NOT operate a motor above its nominal HP rating when a unit is equipped with a steam coil accessory. HOT WATER COIL CAPACITY 1, kw / Mbh Water Coil Model Blower Model Used On l/m / gpm m 3 /s / cfm Entering Water Temperature Minus Entering Air Temperature, C / F 21 / 70 32 / 90 43 / 110 54 / 130 66 / 150 1.1 / 2400 78.0 / 266 101.3 / 346 124.7 / 426 148.5 / 507 169.7 / 579 KEU090 57 / 15 1.4 / 3000 87.7 / 299 113.3 / 387 139.6 / 477 186.6 / 637 190.4 / 650 1HW0451 1.7 / 3600 95.5 / 326 124.0 / 423 153.0 / 522 182.1 / 622 208.1 / 710 1.5 / 3200 90.3 / 308 117.1 / 400 144.6 / 494 172.1 / 588 196.6 / 671 KEU120 57 / 15 1.9 / 4000 100.2 / 342 130.2 / 445 160.7 / 549 191.3 / 653 218.6 / 746 2.3 / 4800 108.3 / 370 140.9 / 481 174.3 / 595 207.5 / 708 237.4 / 810 1 These capacities do not include any blower motor heat. NOTE: Water Temperature Drop, C = 16.71 x kw l / s F = 2 x Mbh GPM CAUTION: Do NOT operate a motor above its nominal HP rating when a unit is equipped with a hot water coil accessory. PRESSURE DROP VS L/M / GPM 1HW0450 1HW0451 Meters (H2O) = 45,942 xkpa Feet (H 2O) = 2031 x psi l/m / gpm 38 / 10 76 / 20 114 / 30 Pressure Drop, kpa / psig 0.7 / 0.10 2.2 / 0.32 4.7 / 0.67 l/m / gpm 57 / 15 114 / 30 170 / 45 Pressure Drop, kpa/ psig 1.2 / 0.17 4.0 / 0.58 8.5 / 1.22 CAPACITY CORRECTION VS L/M / GPM 1HW0450 1HW0451 l/m / gpm 76 / 20 114 / 30 Capacity Correction 1.12 1.15 l/m / gpm 114 / 30 170 / 45 Capacity Correction 1.11 1.15 Unitary Products Group 3

BLOWER PERFORMANCE KEU090 - SUPPLY AIR BLOWER PERFORMANCE 1 - (M 3 /S) AIRFLOW BLOWER ESP 2 OUTPUT INPUT ESP 2 OUTPUT INPUT ESP 2 OUTPUT INPUT ESP 2 OUTPUT INPUT ESP 2 OUTPUT INPUT SPEED (Pa) (kw) (kw) (Pa) (kw) (kw) (Pa) (kw) (kw) (Pa) (kw) (kw) (Pa) (kw) (kw) RPM 1.1 m 3 /s 1.3 m 3 /s 1.4 m 3 /s 1.6 m 3 /s 1.7 m 3 /s 600 87 0.46 0.59 64 0.52 0.66 32 0.45 0.73 - - - - - - 650 122 0.52 0.66 102 0.58 0.72 74 0.65 0.82 17 0.72 0.90 - - - 700 149 0.57 0.73 131 0.63 0.80 107 0.71 0.89 72 0.79 0.99 30 0.87 1.09 800 228 0.72 0.90 211 0.79 0.99 191 0.88 1.10 161 0.97 1.21 122 1.06 1.32 850 293 0.83 1.04 275 0.92 1.16 255 1.02 1.28 226 1.12 1.38 191 1.22 1.53 900 308 0.86 1.07 293 0.95 1.19 273 1.06 1.32 243 1.15 1.43 208 1.27 1.57 1000 392 1.01 1.26 379 1.10 1.38 362 1.21 1.48 340 1.35 1.65 308 1.50 1.85 KEU090 - SUPPLY AIR BLOWER PERFORMANCE 1 - (CFM) BLOWER AIRFLOW SPEED ESP 2 OUTPUT INPUT ESP 2 OUTPUT INPUT ESP 2 OUTPUT INPUT ESP 2 OUTPUT INPUT ESP 2 OUTPUT INPUT RPM (IWG) (BHP) (kw) (IWG) (BHP) (KW) (IWG) (BHP) (kw) (IWG) (BHP) (kw) (IWG) (BHP) (kw 2400 CFM 2700 CFM 3000 CFM 3300 CFM 3600CFM 600 0.35 0.62 0.59 0.26 0.70 0.66 0.13 0.78 0.73 - - - - - - 650 0.49 0.70 0.66 0.41 0.78 0.72 0.30 0.87 0.82 0.07 0.96 0.90 - - - 700 0.60 0.77 0.73 053 0.85 0.80 043 0.95 0.89 0.29 1.06 0.99 0.12 1.17 1.09 800 0.92 0.97 0.90 0.85 1.06 0.99 0.77 1.18 1.10 0.65 1.30 1.21 0.49 1.42 1.32 850 1.18 1.11 1.04 1.11 1.24 1.16 1.03 1.37 1.28 0.91 1.50 1.38 0.77 1.64 1.53 900 1.24 1.15 1.07 1.18 1.28 1.19 1.10 1.42 1.32 0.98 1.55 1.43 0.84-1.70 1.57 1000 1.58 1.35 1.26 1.53 1.48 1.38 1.46 1.63 1.48 1.37 1.81 1.65 1.24 2.02 1.85 KEU120 - SUPPPLY AIR BLOWER PERFORMANCE 1 (M 3 /S) AIRFLOW BLOWER ESP 2 OUTPUT INPUT ESP 2 OUTPUT INPUT ESP 2 OUTPUT INPUT ESP 2 OUTPUT INPUT ESP 2 OUTPUT INPUT SPEED (Pa) (kw) (kw) (Pa) (kw) (kw) (Pa) (kw) (kw) (Pa) (kw) (kw) (Pa) (kw) (kw) RPM 1.5 m 3 /s 1.7m 3 /s 1.9 m 3 /s 2.0 m 3 /s 2.3 m 3 /s 700 122 0.75 0.94 84 0.87 1.09 35 0.99 1.24 - - - - - - 800 208 0.93 1.16 176 1.05 1.32 131 1.19 1.48 74 1034 1.64 - - - 910 293 1.10 1.38 263 1.27 1.57 226 1.43 1.75 174 1.62 1.99 107 1.83 2.24 950 340 1.20 1.50 312 1.39 1.71 275 1.58 1.95 223 1.78 2.18 161 1.99 2.44 1000 387 1.30 1.62 362 1.50 1.85 327 1.71 2.10 280 1.94 2.38 216 2.16 2.65 KEU120- SUPPLY AIR BLOWER PERFORMANCE 1 (CFM) AIRFLOW BLOWER ESP 2 OUTPUT INPUT ESP 2 OUTPUT INPUT ESP 2 OUTPUT INPUT ESP 2 OUTPUT INPUT ESP 2 OUTPUT INPUT SPEED (IWG) (BHP) (kw) (IWG) (BHP) (kw) (IWG) (BHP) (kw) (IWG) (BHP) (kw) (IWG) (BHP) (kw) RPM 3200 3600 4000 4400 4800 700 0.49 1.01 0.94 0.34 1.17 1.09 0.14 1.33 1.24 - - - - - - 800 0.84 1.25 1.16 0.71 1.42 1.32 0.53 1.60 1.48 0.30 1.80 1.64 - - - 910 1.18 1.48 1.38 1.06 1.70 1.57 0.91 1.92 1.75 0.70 2.18 1.99 0.43 2.45 2.24 950 1.37 1.61 1.50 1.26 1.86 1.71 1.11 2.12 1.95 0.90 2.39 2.18 0.65 2.67 2.44 1000 1.56 1.75 1.62 1.46 2.02 1.85 1.32 2.30 2.10 1.13 2.60 2.38 0.87 2.90 2.65 1 Unit resistance is based on a wet evaporator coil and clean filters. 2 Available static pressure in IWG (Pa) to overcome the resistance of the duct system and any accessories added to the unit. NOTE: Motors can be selected to operate into the service factor because they are located in the moving air stream, upstream of any heating device. Units with steam or hot water coils are the only exception. On these units the BHP must not exceed the nominal HP rating of the motor. LEGEND: RPM range for the standard factory-mounted drive components. Exceeds the BHP limitation of the standard factory-mounted blower motor 4 Unitary Products Group

STATIC RESISTANCES FOR UNIT ACCESSORIES Static Resistances, pascal m 3 /s 1.1 1.3 1.4 1.6 1.7 10 kw 2.48 2.48 2.48 4.96 4.96 Electric Heat 16 kw 2.48 4.96 4.96 7.44 9.92 26 kw 7.44 9.92 12.40 14.88 17.36 KEU090 36 kw 12.40 17.36 19.84 24.80 27.28 Supply Air Plenum 7.44 7.44 9.92 12.40 14.88 Return Air Grille 4.96 7.44 9.92 12.40 14.88 Hot Water Coil 27.28 34.75 42.16 49.60 57.04 Steam Coil 24.80 29.76 34.72 39.68 47.12 m 3 /s 1.5 1.7 1.9 2.0 2.3 10 kw 4.96 4.96 7.44 7.44 9.92 Electric Heat 16 kw 7.44 9.92 12.40 14.88 17.36 26 kw 14.88 17.36 22.32 27.28 32.24 KEU120 36 kw 27.32 27.28 34.72 42.16 49.60 Supply Air Plenum 12.40 14.88 17.36 19.84 24.80 Return Air Grille 12.40 14.88 17.36 19.84 24.80 Hot Water Coil 47.12 59.52 74.40 86.80 99.20 Steam Coil 39.68 47.12 57.04 66.96 76.88 Static Resistance, IWG CFM Unit Model Accessory 2400 2700 3000 3300 3600 10 kw 0.01 0.01 0.01 0.02 0.02 Electric Heat 16 kw 0.01 0.02 0.02 0.03 0.04 26 kw 0.03 0.04 0.05 0.06 0.07 KEU090 36 kw 0.05 0.07 0.08 0.10 0.11 Supply Air Plenum 0.03 0.03 0.04 0.05 0.06 Return Air Grille 0.02 0.03 0.04 0.05 0.06 Hot Water Coil 0.11 0.14 0.17 0.20 0.23 Steam Coil 0.10 0.12 0.14 0.16 0.19 CFM 3200 3600 4000 4400 4800 10 kw 0.02 0.02 0.03 0.03 0.04 Electric Heat 16 kw 0.03 0.04 0.05 0.06 0.07 26 kw 0.06 0.07 0.09 0.11 0.13 KEU120 36 kw 0.09 0.11 0.14 0.17 0.20 Supply Air Plenum 0.05 0.06 0.07 0.08 0.10 Return Air Grille 0.05 0.06 0.07 0.08 0.10 Hot Water Coil 0.16 0.24 0.30 0.35 0.40 Steam Coil 0.18 0.19 0.23 0.27 0.31 Unitary Products Group 5

SUPPLY AIR PLENUM PERFORMANCE DATA M 3 /S Mode l KEU 090 m 3 /s Face Velocity (MPM) Soun d Powe r db (10) 12 Watts Vertical Louvers 1 0 Spread Throw (Meters) 3 Min Max Min Max Angle of Deflection Horizontal Vertical Louvers 1 Louvers 2 22 1 2 Spread Spread (Meters) 3 0 18 Throw (Meters) 3 Horizontal Vertical Louvers 1 Louvers 2 45 Spread Spread (Meters) 3 0 18 Throw (Meters) 3 Horizontal Louvers 2 Spread 3 0 18 (Meters) Drop (Meters) 4 Min Max Min Max Drop (Meters) 4 Min Max Min Max Drop (Meters)4 1.1 187 20 14.2 22.4 6.0 8.8 5.7 2.7 10.3 16.1 6.9 10.0 5.1 2.4 7.9 11.8 13.6 19.7 2.7 1.5 1.3 210 21 16.1 25.2 6.6 9.7 6.0 3.0 11.8 17.9 7.6 10.9 5.4 2.7 8.8 13.6 14.5 21.5 3.0 1.5 1.4 234 22 17.9 27.9 7.2 10.6 6.3 3.0 12.7 20.0 8.2 12.1 5.7 2.7 9.7 15.2 15.8 23.7 3.0 1.5 1.6 257 23 19.7 30.7 7.9 11.5 6.3 3.0 13.9 22.1 8.8 13.3 5.7 2.7 10.6 16.7 17.0 25.8 3.0 1.5 1.7 280 24 21.5 33.4 8.5 12.4 6.6 3.3 15.2 24.0 9.7 14.2 6.0 3.0 11.5 18.2 18.4 27.6 3.3 1.8 1.5 249 22 19.1 29.7 7.6 11.2 6.3 3.0 13.6 21.2 8.8 13.0 5.7 2.7 10.3 16.1 19.4 24.9 3.0 1.5 1.7 280 24 21.5 33.4 8.5 12.4 6.6 3.3 15.2 24.0 9.7 14.2 6.0 3...0 11.5 18.2 18.2 27.6 3.3 1.8 120 1.9 312 26 23.7 37.3 9.1 13.6 6.6 3.3 17.0 26.7 10.6 15.2 6.0 3.0 12.7 20.0 20.3 31.0 3.3 1.8 2.0 344 28 26.1 41.0 10.0 14.8 6.9 3.6 18.8 29.4 11.5 17.3 6.3 3.3 14.2 22.1 23.1 34.9 3.6 1.8 2.3 374 30 28.5 44.6 10.6 16.1 6.9 3.6 20.6 32.2 12.4 18.8 6.3 3.3 15.5 24.3 25.8 38.6 3.6 1.8 1 Adjusting the vertical louvers varies the throw, the spread and the drop. 2 Adjusting the horizontal louvers only varies the drop. 3 The velocity of the air is 38m/min. at the minimum distance and 18.2m/min. at the maximum distance. 4 The velocity of the conditioned air at the bottom of the drop is 15.2m/min. Drafts occur if the drop extends into the occupied level of the conditioned space SUPPLY AIR PLENUM PERFORMANCE DATA CFM Mode l KEU 090 CFM Face Velocity (FPM) Soun d Powe r db (10) 12 Watts Vertical Louvers 1 0 Spread Angle of Deflection Horizontal Vertical Louvers 1 Louvers 2 22 1 2 Spread Horizontal Vertical Louvers 1 Louvers 2 45 Spread Horizontal Louvers 2 Throw Spread (Feet) 3 (Feet) 3 0 18 Throw Spread (Feet) 3 (Feet) 3 0 18 Throw Spread (Feet) 3 3 0 18 (Feet) Min Max Min Max Drop (Feet) 4 Min Max Min Max Drop (Feet) 4 Min Max Min Max Drop (Feet)4 2400 615 20 47 74 20 29 19 9 34 53 23 33 17 8 26 39 45 65 9 5 2700 690 210 53 83 22 32 20 10 39 59 25 36 18 9 29 45 48 71 10 5 3000 770 220 59 92 24 35 21 10 42 66 27 40 19 9 32 50 52 78 10 5 3300 845 23 65 101 26 38 21 10 48 73 29 44 19 9 35 55 56 85 10 5 3600 920 24 71 110 28 41 22 11 50 79 32 47 20 10 38 60 60 91 11 6 3200 820 22 63 98 25 37 21 10 45 70 29 43 19 9 34 53 64 82 10 5 3600 920 24 71 110 28 41 22 11 50 79 32 47 20 10 38 60 60 91 11 6 120 4000 1025 26 78 123 30 45 22 11 56 88 35 52 20 10 42 66 67 102 11 6 4400 1130 28 86 135 33 49 23 12 62 97 38 57 21 11 47 73 76 115 12 6 4800 1230 30 94 147 35 53 23 12 68 106 41 62 21 11 51 80 85 127 12 6 1 Adjusting the vertical louvers varies the throw, the spread and the drop. 2 Adjusting the horizontal louvers only varies the drop. 3 The velocity of the air is 125/ft/min. at the minimum distance and 60ft/min. at the maximum distance. 4 The velocity of the conditioned air at the bottom of the drop is 50 ft/min. Drafts occur if the drop extends into the occupied level of the conditioned space 6 Unitary Products Group

BLOWER MOTOR AND DRIVE DATA Model Motor (kw/hp)* Blower Range (RPM) KEU090 1.1 / 1 1 2 650/850 KEU120 1.5 / 2 700/910 Adjustable Motor Pulley Fixed Blower Pulley Belt Pitch Dia (mm/in.) 86-112 / 3.4-4.4 86-112 / 3.4-4.4 Bore (mm/in.) Pitch Dia. (mm/in.) Bore (mm/in.) Designation Pitch Lg. (mm/in.) 22.2 / 7 8 190 / 7.5 25 / 1 A37 973 / 38.3 22.2 / 7 8 178 / 7.0 25 / 1 A37 973 / 38.3 *All motors are 1450 RPM and have a 56 frame, inherent protection and permanently lubricated ball bearings The motors have a solid base and a 1.15 service factor. All 3-phase motors are wired for 380/415V power supply. PHYSICAL DATA - UNITS AND ACCESSORIES Evaporator Coil Description Unit Model KEU090 KEU120 Rows Deep & Rows High 3 x 27 3 x 32 Finned Length - mm/inches 1168 / 46 1168 / 46 Face Area - square meters/square feet 0.80 / 8.6 0.95 / 10.2 Centrifugal Blower (Forward Curve) Filters (Throwaway) Tube OD - mm/inches 9.5 / 3 8 9.5 / 3 8 Fins per 25mm (1in.) 13 13 Wheel Dia. x Width - mm (inches) 381 x 381 (15 x 15) Motor 1 Nominal HP Rating 1 1 2 2 381 x 381 (15 x 15) 406mm x 635mm x 25mm Quantity per unit 4 4 (16" x 25" x 1") Face area - square meters/square feet 1.03 / 11.1 1.03 / 11.1 Distributor One per unit 5-3-10 5-3-12 Operating Weight kg/lbs Hot Water Coil Steam Coil Basic Unit 145 / 320 150 / 330 Accessories Supply Plenum 46.3 / 102 Return Air Grille 6.8 / 15 Hot Water Coil 37 / 82 Steam Coil 38.5 / 85 Base 27 / 60 Electric Heater 10 kw 28.5/ 63 16 kw 29.9 / 66 26 kw 32.2 / 71 36 kw 33.5 / 74 Tube OD, mm/inches 12.7 / 1 2 (copper) Rows Deep 2 Fins per 25mm (1in.) 8 (aluminum) Face Area, square meters/square feet 0.63 / 6.8 Connections (supply & return) 25mm (1 in.) NPTE Outer Tube OD, mm/inches/ 25 / 1 (brass) Rows Deep 1 Fins per 25mm (1in.) 8 (aluminum) Face Ares, square meters/square feet 0.61 / 6.6 Connection Inlet Outlet 38mm (1 1 2 in.) NPTE 38mm (1 1 2 in.) NPTE % Nickel 59.2 Electric Heater Heater Elements % Chromium 16.0 Watt Density, watts/sq. in. 59.0 Face Area, square meters/square feet 0.28 / 3.0 Shipping Volume - cubic meters /cubic feet(basic Unit) 1.5 / 53 1 Refer to Blower Motor and Drive Data table for additional motor and drive data. 2 Refer to the unit Installation Instruction 550.39-N4YI for the distributed weight of the evaporator blower unit. Unitary Products Group 7

UNIT DIMENSIONS ACCESSORIES ELECTRIC HEATER Add 381mm (15") to Unit Height when using 10, 16, 26 or 36kW Heater SUPPLY AIR PLENUM Add 686mm (27") to Unit Height when used BASE Add 610mm (24") to Unit Height when used MINIMUM CLEARANCES (mm /in.) Side with RETURN AIR opening - 610 / 24 Side with SUPPLY AIR opening - 610 / 24 1 Side with PIPING CONNECTIONS - 1549 / 61 2 Side opposite PIPING CONNECTIONS - 660 / 26 3 Bottom - 4 1 Overall dimension of the unit will vary if an electric heater, a supply air plenum or a base is used. 2 This dimension is required for removal of the DX coil. Only 660mm (26") is required for normal servicing. 3 If the DX coil has to be removed, this dimension is required to loosen screws that secure the coil to the unit frame. This dimension is also required for blower motor access if the piping connectiions are made on the opposite side of the unit. 4 Allow enough clearance to trap the condensate drain line. 8 Unitary Products Group

ACCESSORY DIMENSIONS REFER TO THE UNIT DRAWING FOR DUCT FLANGE DIMENSIONS. 38 1 1 2 NPTE 1NF0450 Coil Model * KEU090 Unit 1320 A Steam 635 B Coil 127 CDimensions, 64 D mm 67 E (inches) 270 F 51 2 1HW0451* Coil Model KEU090 Unit 1320 A Water 635 B Coil 127 C Dimensions 43 D 60 E, mm 270 F (inches) 149 G 25 1 NPTE 51 2 51 2 WITH ELECTRIC HEAT - Remove the 64mm (2 1 2 in.) knockout from the rear panel of the plenum. Route the power wiring conduit through this opening and connect it to the field-supplied fitting on the electric heat accessory. Connect the power wiring to the fuse block in the heater control box. Install the control wiring per basic unit instruction Form 550.39- N4YI. Do not route any field control wiring through the plenum. WITHOUT ELECTRIC HEAT - Install the power and the control wiring per basic unit instruction Form 550.39-N4YI. Do not route any wiring through the plenum and do not remove this knockout. KNOCKOUT FOR POWER WIRING Accessory Model 1SP0451 Unit Model KEU090 KEU120 Plenum Dimensions, mm (inches) A B C D E F G H K L 1324 (52 1 8) 718 (28 1 4) 699 (27 1 2) 1267 (49 7 8) 454 (17 7 8) 222 (8 3 4) 22.2 ( 7 8) 181 (7 1 8) 387 (15 1 4) 44 (1 3 4) Unitary Products Group 9

1 2 ACCESSORY DIMENSIONS ELECTRIC HEATER 19 3 4 ACCESS OPENING FOR POWER SUPPLY WIRING Add a 32mm (1 1 4") conduit fitting to the 43.7mm (1 23 32") hole for wire sizes up through #1 AWG. Remove the knockout ring and add a 38mm (1 1 2") conduit fiting to the 50mm (1 31 32" ) hole for wire sizes up through #0 AWG. 13 WIRING HARNESS LOCATION This opening in the bottom of the heater control box is used for the wiring harness that connects the heater accessory to the basic unit. It is provided with a squeeze connector for securing the wiring harness. It's location corresponds to the location of the 43.7mm (1 23 32") Accessory Model 2HS04501050 2HS04501650 2HS04502650 2HS04503650 Nom. kw 10 16 26 36 Heater Dimensions, mm (inches) A B C D E F G H K L M 692 (27 1 4) 641 (25 1 4) 362 (14 1 4) 25 (1) 102 (4) 13 ( 1 2) 140 (5 1 2) 38 (1 1 2) 38 (1 1 2) 565 (22 1 4) 489 (19 1 4) ELECTRICAL DATA COOLING ONLY UNITS Model Blower Motor kw/hp Power Supply FLA Maximum Fuse Size* Amps Maximum Wire Length* *m (Ft.) KEU090 1.1 / 1 1 2 380/415-3+N-50 3.7 5 197 (650) KEU120 1.5 / 2 380/415-3+N-50 4.5 5 152 (500) * Dual element, time delay fuses. ** Based on three 60 C, 14 AWG, insulated copper conductors in steel conduit and a 3% voltage drop. UNITS WITH ELECTRIC HEAT Model Nom. Heat Volt Heat FLA Motor FLA Ampacity KEU090 KEU120 Maximum Fuze Size* Amps Wire Size (AWG) Maximum Wire Length** m (Ft.) 7.5 415 10.4 3.7 17.6 20 12 53.2 (175) 12.0 415 16.6 3.7 25.4 30 10 53.2 (175) 19.4 415 27.0 3.7 38.4 40 8 60.8 (200) 26.9 415 37.4 3.7 51.4 60 6 68.4 (225) 7.5 415 10.4 4.5 18.6 20 12 45.6 (150) 12.0 415 16.6 4.5 26.4 30 10 53.2 (175) 19.4 415 27.0 4.5 39.4 40 8 60.8 (200) 26.9 415 37.4 4.5 52.4 60 6 68.4 (225) * Dual element, time delay fuses. ** Based on three 60 C, 14 AWG, insulated copper conductors in steel conduit and a 3% voltage drop. 10 Unitary Products Group

FIELD WIRING Cooling only 4 - WIRE TERMINALS ON 1-STAGE COOLING THERMOSTAT 2TH0870124 TERMINALS ON BLOCK 3TB OF THE BLOWER UNIT CONTROL WIRING Units with steam or hot water coil accessory Units with electric heat accessory NOTES; 1 Only required for 2-stage cooling. 2 Not required on 10kw heaters (only one-stage heating). Unitary Products Group 11

P.O. Box 1592, York, Pennsylvania USA 17405-1592 Subject to change without notice. Printed in U.S.A Copyright by York International Corporation 1994. All Rights Reserved. 550.39TG4YI (Supersedes: Nothing)