Brand : CCC. AIR DIFFUSION EQUIPMENT EGG CRATE GRILLES Series : CCC-ECRG

Similar documents
CONDOR. Supply air ceiling QUICK FACTS

Linear Floor Heaters

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

Commercial Evaporative Cooling

Ceiling air diffuser INDULTHERM INDULTHERM-e

DR AS 5389:2016 Space heating and cooling and ventilation systems Calculation of energy consumption. The physical testing

lindab we simplify construction LindabIndoorClimateSolutions Product overview Airborne Solutions

Commercial Evaporative Air Conditioning

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

FIRE & SMOKE DAMPERS. Meeting tomorrow's requirements for fire and smoke protection today.

SECTION AIR OUTLETS AND INLETS

IMPROVING AIR DISTRIBUTION THROUGH TECHNOLOGY

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

TLW Therma-Fuser Linear Sidewall Thermally Powered VAV Diffuser

High performance evaporative cooling. Unbelievable value. Upgrade to the new touch screen MagIQtouch Controller.

CLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE

Air Handling Units. Ranging from 15 to 2,000+ tons and 500 to 400,000+ CFM

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Static cooling ceiling system SKS-4/3 DS 4094 E /1. Technical Selection

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS

EHH SERIES DRAW THROUGH FAN COILS CFM

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

COMPANY PROFILE 2013

PREEVA air handling unit

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

Central Heating and Ventilation

Ceiling diffusers. Type DLQL

Performance Climate Changer Next generation air handler from Trane

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Bypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Office

MANUFACTURER OF FIRE EXTINGUISHING AGENTS

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

Fan Coil Unit CULTRA

Whole of Home ADD ON. Add some cool comfort to your life. That s better. That s Actron.

THERMA FUSER SIDEWALL LINEAR VAV DIFFUSER

Ceiling swirl diffusers

Indirect Evaporative Air Conditioning

BOWEN. Corporate Profile. Commercial Fitout Solutions INTERIORS

Ceiling swirl diffusers

Enriching Environments

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

ANSI RAB QMS. Parag Energy Efficient Axial Flow FRP Fans

Unico Training. Class for R E Michel Salesmen

Wideline presents The Paragon Range

Improved Thermal Comfort & Energy Efficiency with low-pressure VAV diffusion design

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

Technical Data Ducted Three Phase Split System Air Conditioner

THE GREAT HALL; A SOURCE OF GREAT INSPIRATION

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

Specialist Anodising Company Limited. creativity focused innovation for the global cosmetics industry

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Onyx Sliding Patio Door Lock. ASSA ABLOY, the global leader in door opening solutions

Breathtaking cooling Amazing durability Unbelievable value

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

Four ways of performance improvement. 4 ways to improve perf

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers

FCC Fan-Coil Units High-Performance, Vertical

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

TTC. TTC Active supply air diffuser. Product description. Introduction SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Simplicity

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

Ceiling air diffuser INDULTHERM INDULTHERM-e

TTC. TTC Active supply air diffuser. Product description SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Introduction. Simplicity

City of Duluth Festival Center 04/25

Life just got even more comfortable. Ducted Air Conditioning with Touch Screen

Quality Design Innovation Functionality

Indirect Evaporative Air Conditioning

SIZING HANDBOOK & APPLICATION GUIDE

Specifying the Right Rooflight. T: +44 (0) E:

iq Star LYRA II chilled beam cassette

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

SECTION FAN COIL UNITS

(57.7) X. March 2006 PRODUCTS. ... the complete solution

Classification of Fire Performance of Wall and Ceiling Lining Materials

Braemar evaporative cooling So clever, so quiet, so cool

LOW PROFILE EVAPORATORS

BUILD YOUR REPUTATION ON OURS. Universal Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG

Gas-fired unit heaters for indoor installation

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

REDEFINING INNOVATION AND SUSTAINABILITY IN THE DESIGN OF INTERIOR ACOUSTICS

HOTEL CHILLED BEAM IQ STAR SILENCIA

Concealed Door Closers

Company Profile. Engineered HVAC Solutions (EHVACS) Melbourne Australia

Airflex Radial & ISO Thermal pipe

Ducted Air Conditioning

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Accredited SIA ACS & ISO 9001:2001 ISO & ISO BSIA Member

Krantz. Multifunction exposed ceiling AVACS. Cooling and heating systems

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Ministry of Petroleum Building, Riyadh. Commercial:

Packaged Air Conditioning Custom Build Solutions

Evaporative air conditioning.

PROJECTS & REACTIVE MAINTENANCE SPECIALISTS

Evaporative air conditioning. Breathtaking cooling. Amazing durability. Unbelievable value.

Transcription:

Brand : CCC AIR DIFFUSION EQUIPMENT EGG CRATE GRILLES Series : CCC-ECRG 1 P a g e

VISION To produce high quality products, high standard of creativity in design and excellent credibility in reputation MISSION Serve customer with satisfactory and reliable works and products Chan Chuan Chang Metal Works was established in 1975, committed to the vision to manufacture good quality Air Diffusion Equipment. After building up its reputation in the industry as a top manufacturer, the company registered the logo with the Registry of Trade and Patents (Singapore). From then onwards, all equipment which has the trade mark symbolise our commitment to serve our customer with satisfactory and reliable works and products. Our products have been tested by VIPAC, testing laboratory at Victorian technology Centre, Port Melbourne, Victoria. Furthermore, the results are NATA Certified (National Association of Testing Authorities, Australia) to ADC 10623 R3 (Air Diffusion Council, USA) and are officially endorsed in countries which are signatories to the I.L.A.C agreement-namely, Australia, New Zealand, Britain, USA and Malaysia. We were proud to introduce the Heavy Duty Aluminium Computer Floor Grille, Series : CR to the industry in 1991. This has been a breakthrough as the grille are able to provide adequate air flow whilst maintaining the weight of any person or equipment. This is verified by the Comprehensive Loading Test performed by Singapore Institute of Standard & Industrial Research (SISIR), currently known as Spring Singapore. Series : CR has since then been installed in many computer rooms, wafer manufacturing plant and places which require the product. 2 P a g e

COMPANY MILESTONE 1975 Established with the vision to manufacture high quality Air Diffusion Equipment to meet future needs and demands. Together with a team of experienced Engineers & Craftsman dedicated to Chan Chuan Chang s Motto Commitment, Creativity & Credibility, we produced good quality products with high standard of creativity in design and maintained excellent credibility in reputation. 1982 Registered with the Registry of Trade and Patents (Singapore), CCC Trade Mark has since became a household name in its industry. 1986 Chan Chuan Chang (CCC) products are tested by VIPAC, a testing laboratory at Victorian Technology Centre, Port Melbourne, Victoria. These results are NATA Certified (National Association of Testing Authorities, Australia) to ADC 10623 R3 (Air Diffusion Council, USA) and are officially endorsed in countries which are signatories to the I.L.A.C agreement namely, Australia, New Zealand, Britain, USA and Malaysia. 1991 CCC Aluminium Computer Floor Air Grille was sent for Comprehensive Loading Test conducted by Singapore Institute of Standard & Industrial Research (SISIR) and achieved excellent results. 1997 CCC was awarded ISO 9002 Certification. Our impressive list of satisfied clients is testimony to CCC s motto Commitment, Creativity and Credibility. 2005 CCC has improved its quality management system with respect to the ISO 9001:2000 standard due to our commitment towards quality improvement in our products and customer satisfaction. We thank you for your faith and support in our products. We will continue to strive harder to exceed your demand & satisfaction. 2012 CCC was awarded ISO 9001:2008 Certification by BVQI Accreditation. CCC also became a certified member of Air Movement and Control Association International (AMCA). Our Low Leakage dampers were tested according to AMCA standards and received certifications. 3 P a g e

MODEL: ECRG Construction High quality extruded aluminium sections. Cell sizes of 12x12x12mm or 16x16x12mm aluminium squares. Finishing in white powder coating. Description CCC egg-crate grilles are specially designed to have pleasing appearance with least resistance to air flow. The cell size of these grilles are of 12x12x12mm or 16x16x12mm squares in aluminium or steel frame. Bars have been specially designed by CCC Specialist to provide the optimum in airflow and low sound level characteristics. Core Sections can also be made totally removable by the use of concealed spring fixing which eliminates screw fastening on the face of the grille. Accessories Plenum box Volume Control Damper Foam Gasket Anti-Condensation coating Other Optional Features Other colour coatings may be available upon request. Suggestions are also available on request from your CCC specialist. 4 P a g e

Frame Style 5 P a g e

Selecting a Single Deflection Grille To select a grille suitable for your application, two sets of data should be considered: i. The application and its location to occupied spaces on both sides of the grille. ii. The performance characteristics of the actual grille. Three important aspects evolve from these two sets of data. 1. The Air Quantity. 2. The allowable Pressure Drop 3. The Desired Noise Levels. 1. The Air Quantity Measured in litres per second, the air that passes through the grille is determined by the overall system design. The number of size of the grilles to be used is selected by establishing the maximum pressure drop and noise level that can be tolerated in that application. 2. Pressure Drop The total pressure drop encountered through each core pattern at varying neck velocities is set out in pascals the total pressure drop being the sum of the static pressure drop of the air as it passes through the diffuser and the velocity pressure of the air at the neck of the diffuser. 3. Noise Level The maximum permissible NR levels from each grille relate directly to the quantity of air transmitted through any given core style. The following table may be used as a guide to the generally acceptable NR levels for various common use situations: NR LEVELS TYPICAL APPLICATIONS 20 25 Radio, TV, Studios, Churches. 25-30 Live Theatres, Opera Halls, Concert Halls, Band Rooms 30-35 Conference Rooms, Movie Theatres, Lecture Rooms, Private Offices. 35-40 Libraries, General Offices, Laboratories, Restaurants. 40-45 Halls, Corridors, Cafeterias. 45-50 Storerooms, Large Department Stores and Supermarkets. Over 50 Manufacturing Areas. Performance Graphs The performance graphs show Airflow, pressure drop sound levels and throws for each size of the product. Pressure drops are shown as total pressure in Pascals (Pa) Sound Levels are presented as Noise Ratings (N.R.) in db, including a 6db room absorption. The static pressure drops across the grille were measured by using the average static pressure in an oversized plenum box. 6 P a g e

Performance Graph 300MM Long Aspect Table CATEGORY 1 2 3 4 5 6 7 8 GRILLE 100 125 175 250 325 400 500 575 HEIGHT (in mm) 7 P a g e

Performance Graph 600MM Long Aspect Table CATEGORY 1 2 3 4 5 6 7 8 GRILLE 100 125 175 250 325 400 500 575 HEIGHT (in mm) 8 P a g e

Performance Graph 900MM Long Aspect Table CATEGORY 1 2 3 4 5 6 7 8 GRILLE 100 125 175 250 325 400 500 575 HEIGHT (in mm) 9 P a g e

Performance Graph 1200MM Long Aspect Table CATEGORY 1 2 3 4 5 6 7 8 GRILLE 100 125 175 250 325 400 500 575 HEIGHT (in mm) 10 P a g e

Optional Accessories These are some of our optional accessories for your references: Opposed-Blade Damper To vary and control the supply air volume providing a sustained discharge velocity throughout the volume range. Fan-Type Damper To vary and control the supply air volume providing a sustained discharge velocity throughout the volume range. Plenum Box A junction to join various ducts. It is a closed space space inteded to store air and also helps to reduce noise level of the airflow. Anti Condensation Anti-Condensation coating to reduce and prevent sweating for your grilles and diffusers due to the differences of temperature in the surrounding. 11 P a g e