Certification of Translation Accuracy Translation of Document from Dutch to English

Similar documents
CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

P.O. Box NL-2665 ZN Bleiswijk Brandpuntlaan Zuid 16 - NL-2665 NZ Bleiswijk The Netherlands

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

Determination of the fire resistance according to EN : 2006 of vertical linear joints sealed with Henkel PATTEX FR55

2005-CVB-R0192 Onderzoek naar de mogelijke invloed van FirePro aërosol op in werking zijnde computerapparatuur

Determination of the fire resistance according to EN of vertical linear joints sealed with Henkel PATTEX FR66

ENGINEERING EVALUATION

Fire Protection Scover

EM8665 Wireless Vibration Detector

Oracle Retail Management System Release Notes Release Spanish. January 2008

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

7.0 SAMPLE PERMITS, FORMS AND CHECKLISTS SELF INSPECTION CHECKLIST

Burn Injury Investigation Report Preparing a Live Fire Prop for Use Miami-Dade County Fire Rescue Department, November 18, 2011

FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES

EM8651 PIR Motion Detector

Conditions for the provision of services Valid from 1 November only for the Jablotron Alarms series of alarms

Fixed fire protection solutions

FINDINGS FROM FIRE TESTS IN TUNNEL CONSTRUCTIONS WITH VENTILATION SYSTEMS AND FIXED FIRE SUPPRESSION SYSTEMS

GASTEC QA. Approval Requirements 136

ü ü ü and cloud integrated Efficient collaboration Intramural Brand independent & extramural

Milestone XProtect Alarm Matrix Integration 1.0

Food Service Technology Center

GASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment

GASTEC QA. Approval Requirements 69-1

IFLA Guidelines for Satellite Meetings. Approved by the IFLA Professional Committee and the IFLA Governing Board August 2012

Roller Dog. Instruction Manual Model #8023, Model #8024 and Model #8025. Cincinnati, OH USA. Model #8024. Model #8025

ENGINEERING STANDARD FOR FIRE STATIONS ORIGINAL EDITION NOV. 1993

Vehicle Security System VSS3 - Vehicle original remote. Setting Guide - English

SCALES NW EMERGENCY ACTION PLAN

Principles of Cold Insulation

Case No COMP/M MAGNA / DONNELLY. REGULATION (EEC) No 4064/89 MERGER PROCEDURE. Article 6(1)(b) NON-OPPOSITION Date: 16/09/2002

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Operation Manual. HTV10L Hand tool TAB2.8 SWS HTV10L crimping head TAB2.8 - SWS

Oracle Retail Merchandising System Release Notes Release 12.0 May 2006

Chore-Tronics Load Cell Indicator

Individual compliers collection of WEEE

EM8690-R1 Wireless smoke detector

MULTISITE. Multisite Activation. Microsoft Dynamics AX White Paper

BUS ENGINE COMPARTMENT FIRE PROTECTION SYSTEM FIREPRO TEST REPORT PEER REVIEW

Grower Summary PO 005

Instruktions manual. At skræmme fugle med laser!

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

Door/Window Sensor Installation Instructions

GASTEC QA. Approval Requirements 201. Amendment A1. for the GASTEC QA product certificate for Gas service lines to residences and buildings

LEICESTER GRAMMAR SCHOOL TRUST FIRE SAFETY POLICY

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Kitchen Appliance Lift INSTRUCTION MANUAL

LP GAS LEKAGE ALARM. M. G.. D. D. Wickramasinghe 1*, N. Abhayasinghe 2

Operation Manual. HTV10 Hand tool MATE-N-LOK 0,2-0,82 sq.mm HTV10 crimping head MATE-N-LOK 0,2-0,82 sq.mm

Hot Work Permit. Can this job be avoided? Is there a safer alternative? Permit No.:

RISK ENGINEERING GUIDELINE.

GASTEC QA. Approval Requirements 200. for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE)

New insights into ventilation

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

Supply and installation of a gas delivery unit for Hydrogen fluoride (HF) and a vertical furnace

ISO 7010 INTERNATIONAL STANDARD. Graphical symbols Safety colours and safety signs Safety signs used in workplaces and public areas AMENDMENT 1

2 000W CYCLONIC BAGLESS VACUUM

July 22, Stewart Audio Inc. Brian Mccormick Po Box 4058 Mountain View, CA File SV17764 / Project 09CA34798

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

1.0 Basic Principles and Practices of Propane Performance-Based Skills Assessment 2016

User Manual. Dryer Controller M720

Policy Manual Part I-2 Open Burning Permits

Installation and Operation Instructions 1000 Series Siren & Controller

Safety Function: Single-beam Area Access Control (AAC)

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

CabLite VR LED Lighting System Installation Manual

DROP IN POPCORN WARMERS

Fire Protection. A Health and Safety Guideline for Your Workplace. Introduction. Fire Prevention and Control. Workplace Assessment

FIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS

FIREFIGHTER II MANIPULATIVE SKILL OBJECTIVES

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

Reaction to fire classification report No C-rev.1

TUNPROTEC. Active Tunnel Fire Protection

LA GRANGE FIRE DEPARTMENT SEPTEMBER 2017

Oracle Retail Management System Release Notes Release November 2007

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

Evaluation Guideline. regarding the Product Certificate GASKEUR Label HR (High Efficiency, Heating):2010 for Central Heating Appliances

Volterra. Owner s Manual WARNING WARNING WARNING FOR OUTDOOR USE ONLY CAUTION: OUTDOOR FIREPIT TABLE

TECHNICAL GUIDELINES WORKSHEET

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

The Science Behind Water Mist Protection of Typical Building Hazards

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

Legislation & Standards

Dear Customer. To update your printed copy of C/AS7, please make the following changes: Section Previous version January 2017 Amendment 4

Comment on Hawker Stall Fires

Full-scale test of fire detection in a facade using heat detection cable and flame detector

VE.NET GMDSS PANEL USER MANUAL INSTALLATION MANUAL

PartyQ USER S GUIDE Rev. 1.1 for Ver. 1.0 Firmware

Using BIM model for Fire Emergency Evacuation Plan

HOLLY HILL FIRE DEPARTMENT

IFLA Regional Office for Latin America and the Caribbean: Call for Applications to host the Regional Office

User Manual Mini Fridge MF50

Transcription:

Certification of Translation Accuracy Translation of Document from Dutch to English We, ASAP Translate, a professional translation services company having no relation to the customer, hereby certify that the above-mentioned document has been translated by experienced and professional translators and that, in our best judgment, the translated text is a true translation of the original document, which truly reflects the content, meaning and style of the original document. ASAP Translate and company, do not guarantee that the original is a genuine document, or that the statements contained in the original document are true. ASAP Translate assumes no liability for the way in which the customer uses the translation or any third party, including end-users of the translation. A copy of the translation is attached to this certification. Sincerely, ASAP Translate State of Florida Dated: 12/12/2017 P.O. Box 970571 Coconut Creek, FL 33097

Postbus 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk 088 3473 723 nederland@efectis.com Assessment of the functionality of the Proteng fire extinguishing system Report number (this report replaces report 2016-Efectis-R000002) Sponsor Dries 8 B-9870 ZULTE Belgium Author (s) Ing. P.B. Reijman Ing. R.D. Scheepe Project number Report date January 2017 Number of pages 11 All rights reserved. No part of this publication may be reproduced and / or published without the prior permission of. The inspection of the Efectis report to direct stakeholders is permitted. If this report was commissioned, the rights and obligations of the client and the contractor are referred to the General Term s and Conditions for research assignments to or the relevant agreement between the parties..

2017 BV Pagina 1 / 11

INDEX 1. Introduction 3 2. Proteng extinguishing system 3 3. Test program 4 3.1 Proteng IT 4 3.2 Proteng ELECTRO 4 3.3 Proteng ENGINE 5 4. Conclusion 6 ANNEX A: Specifications of Proteng extinguishing system 7 Proteng IT 8 Proteng ELECTRO 9 Proteng ENGINE 10 Proteng AGRO TIR 11 This report consists of eleven pages and may only be used in its entirety. Page 2 / 11

1. INTRODUCTION Commissioned by D & S bvba, Zulte, Belgium, the Efectis Netherlands Fire Safety Center carried out an assessment of the extinguishing capacity of the Proteng extinguishing system. The purpose of the assessment is to record the operation of this extinguishing system under a number of practical conditions. The operation of the extinguishing system was assessed during a number of fire tests carried out. These fire tests were carried out at a fire station in the Netherlands under the direction of the client. An employee from attended the fire tests and recorded the test results. 2. PROTENG EXTINGUISHING SYSTEM The Proteng extinguishing system consists of a plastic hose with a diameter of 18 mm which is filled with the extinguishing agent FM200 (heptafluoropropane). The hose is pressurized and then sealed with end plugs. The hose is then placed in a compartment to be secured with fastening means and the compartment is closed. If a fire starting occurs, the temperature in the compartment will rise. This will also increase the temperature of the Proteng extinguishing hose. With this increasing temperature, the internal pressure in the extinguishing hose will also increase. At any time at a local temperature of 120 ºC the hose will collapse and the FM200 extinguishing agent will be released. This will usually take place at the location of the thermally highest temperature which as a rule will be the seat of the fire. The extinguishing pressure will release the extinguishing agent with some force and the seat of the fire will be extinguished. The Proteng extinguishing system has four products of which the length of the extinguisher hose and thus the amount of extinguishing agent varies. The quantity of extinguishing agent then has a relationship with the maximum volume to be protected. In table 1 the four Proteng products are described. Only hose lengths 40, 100 and 210 cm were evaluated in the tests performed. This was in, respectively, a desktop computer, an electrical distribution box and a motor compartment of a passenger car. Table 1: Proteng products Extinguishing unit Length of extinguishing hose [ cm ] Amount of extinguishing agent [ g ] Proteng IT 40 100 0.25 Proteng Electro 100 250 0.5 Proteng Engine 210 500 1 Proteng Tir Agro a) 400 1000 2 a) product not involved in the tests Maximum protected volume [ m 3 ] The specifications of the various products are shown in appendix A. This report consists of eleven pages and may only be used in its entirety. Page 3 / 11

3. TEST PROGRAM The test program consisted of three test setups in which, in particular, the volume of the test area was chosen in relation to the Proteng product. As a source of ignition, the choice was always made for a fire pit with white spirits (class B) supplemented with spruce wood strips (class A). The product Proteng Tir Agro is not involved in the tests. The tests are all conducted in the open air. The temperature was 13 ºC at an average wind speed of 7 m / s. 3.1 PROTENG IT This product with a hose length of 40 cm is placed at the top of the housing of a Dell desktop computer. On the bottom of the housing the fire tray was placed with white spirits. The side panel remained open. The spirit was ignited and the time measurement started. Test result test 1.1: after 2'45 "the system started and the firebox was immediately extinguished. The fire tray still contained liquid white spirits. A second test was carried out in which the side panel was closed and ignition of the fire tray via removed rear panels took place. Test result test 1.2: after 1'50 "the system started and the firebox was immediately extinguished. The fire tray still contained liquid white spirits. Test 1.1 Proteng in desktop test 1.1: activated system 3.2 PROTENG ELECTRO This product with a hose length of 100 cm is placed at the top of a steel electrical box. The cabinet has a revolving door at the front. The internal dimensions of the cabinet are: 100 x 60 x 25 cm (h x w x d). At a height of 60 cm from the bottom of the cupboard, the fire tray was placed with white spirit. The door was left open ajar to maintain oxygen supply. The spirit was ignited and the time measurement started. Test result test 2.1: after 2'45 "the system started and the firebox was immediately extinguished. The fire tray still contained liquid white spirits. A second test was carried out in which the fire pit was placed on the bottom of the cupboard and in which spruce wood strips were placed on the fire pit. The spirit was ignited and the door was again ajar. This report consists of eleven pages and may only be used in its entirety. Page 4 / 11

Test result test 2.2: after 4'45 "the system started and the firebox, including the wooden strips lying on it, was immediately extinguished. The fire tray still contained liquid white spirits. Test 2.1 Test 2.2 3.3 PROTENG ENGINE This product with a hose length of 210 cm is placed against the inside of a bonnet of a passenger car. The battery has been disassembled from the engine block. In this the fire pit with white spirit and wooden strips was placed. The bonnet was left open ajar to maintain oxygen supply. The spirit was ignited and the time measurement started. Test result test 3.1: after 0'45 "the system started and the firebox including the wooden strips was immediately extinguished. The fire tray still contained liquid white spirits. A second test was carried out in which the fire pit was placed more deeply in the engine block and in which firewood strips were also placed on the fire pit. The spirit was ignited and the bonnet once again was ajar. Test result test 3.2: after 6'30 "the system started and the firebox, including the wooden strips lying on it, was immediately extinguished. The fire tray still contained liquid white spirits. The white arrows indicate the location of the firepitss. brandhaard Test 3.1 Test 3.2 brandhaard This report consists of eleven pages and may only be used in its entirety. Page 5 / 11

4. CONCLUSION In summary, it can be concluded that the Proteng extinguishing system is capable of effectively extinguishing incipient fires in somewhat compartmentalized spaces. The spaces concerned need not be hermetically sealed. It was proven that the extinguishing system is effective on both Class A and Class B fires. It should be noted that although the tests carried out show an effectively operating extinguishing system, the tests have an orienting character in which not all system boundaries have already been investigated. Ing. P.B. Reijman Project leader Special testing & Fire investigations Ing. R.D. Scheepe Manager testing This report consists of eleven pages and may only be used in its entirety. Page 6 / 11

ANNEX A: SPECIFICATIES PROTENG BLUSSYSTEEM This report consists of eleven pages and may only be used in its entirety. Page 7 / 11

PROTENG IT A revolutionary automatic gas extinguishing system that serves the protection of small closed spaces containing computers, servers, Rackmount PCs, distributors for electricity, electrical equipment and the like. The size of the internal space is limited to approx. 0.25 m3. How many users switch off their computers? Computers are often on continuously in offices and households and nobody realizes what can happen and what can be lost. At the moment when it comes to a fire, nobody is often present to intervene in the offices, objects or households as quickly as possible. For such a moment it is sufficient to have the Proteng IT within the PC and there is then no risk of the fire expanding. The entire operating principle is based on one polyamide hose with a diameter of 18 mm and a length of 40 cm in which the effective extinguisher FM-200, with the exact name heptafluoropropane, is under pressure. At a normal temperature, up to 100 g of extinguishing agent is stored in this relatively small space, thanks to a pressure of 5 bar. When heating up the environment by fire, the pressure is increased to 15 bar at a temperature of 100 C. The actual start of the system is activated by a temperature above 120 C when the softening polyamide wall of the hose bursts exactly at the location of the highest thermal load and the extinguishing gas is released into the room. This gas reliably and effectively burns the fire in the bud, during the extinguishing no electrical parts are damaged, nor during use. The entire system is fully automatic, requires no operation and starts immediately if it comes to a fire. The system protects you and your property 24 hours a day. Technical parameters: Weight Proteng IT 240 g Weight of the extinguishing agent 100 g FM200 (heptafluoropropane) The material of the detection tube is polyamide Dimensions of the tube: length 40 cm / diameter 18 mm Pressure of natural vapors at 20 C 5 bar Pressure of natural vapors at 100 C 15 bar This report consists of eleven pages and may only be used in its entirety. Page 8 / 11

PROTENG ELECTRO A revolutionary automatic gas extinguishing system that serves the protection of small enclosed spaces in which the distributors for electricity, electrical equipment, ventilation technology and the like. The size of the internal space is limited to approx. 0.5 m3. Nowadays there is electrical equipment all around us. It is important to realize that many fires are caused by a short circuit and this at times when no one is present to intervene immediately. Proteng ELECTRO is a fully automatic and simple system that can monitor both you and your property 24 hours a day. The entire working principle is based on one polyamide hose with a diameter of 18 mm and a length of 100 cm in which the effective extinguisher FM-200, with the exact name heptafluoropropane, is under pressure. At a normal temperature, up to 250 g of extinguishing agent is stored in this relatively small space, thanks to a pressure of 5 bar. When heating up the environment by fire, the pressure is increased to 15 bar at a temperature of 100 C. The actual start of the system is activated by a temperature above 120 C when the softening polyamide wall of the hose bursts exactly at the location of the highest thermal load and the extinguishing gas is released into the room. This gas reliably and effectively burns the fire in the bud, during the extinguishing no electrical parts are damaged, nor during use. The entire system is fully automatic, requires no operation and starts immediately if it comes to a fire. The system protects you and your property 24 hours a day. Technical parameters: Weight Proteng ELECTRO 430 g Weight of the extinguishing agent 250 g FM200 (Heptafluoropropane) The material of the detection tube is polyamide Dimensions of the tube: length 100 cm / diameter 18 mm Pressure of natural vapors at 20 C 5 bar Pressure of natural vapors at 100 C 15 bar This report consists of eleven pages and may only be used in its entirety. Page 9 / 11

PROTENG ENGINE A revolutionary automatic gas extinguishing system that serves the protection of enclosed engine compartments for cars, buses, trucks and other motor vehicles and machines. On the road every day of the year several cars and other vehicles burn, not only because of an accident, but also often due to a bad technical condition of a vehicle. The Proteng ENGINE system is an original automatic extinguishing system that can protect your car from the start of a fire. At the moment of fire, the crew of the vehicle is in direct danger (people can not get out of the vehicle and burns) or one is in shock and acts short-circuited (you do not know how to use a fire extinguisher, the fire extinguisher can not be found, one opens the engine compartment and therefore does not stimulate the fire anymore, everything takes too long). Proteng ENGINE is installed in the engine compartment and carries out the extinguishing process for you. It is a fully automatic system that does not depend on energy, operation or other aspects and protects you 24 hours a day and not only during driving but also during parking. A big advantage of this system is an exceptionally simple and flexible assembly. The entire operating principle is based on one polyamide hose with a diameter of 18 mm and a length of 210 cm in which the effective extinguisher FM-200, with the exact name heptafluoropropane, is under pressure. At a normal temperature, up to 500 g of extinguishing agent is stored in this relatively small space, thanks to a pressure of 5 bar. When heating up the environment by fire, the pressure is increased to 15 bar at a temperature of 100 C. The actual start of the system is activated by a temperature above 120 C when the softening polyamide wall of the hose bursts exactly at the location of the highest thermal load and the extinguishing gas is released into the room. This gas reliably and effectively burns the fire in the bud, during the extinguishing no electrical parts are damaged, nor during use. The entire system is fully automatic, requires no operation and starts immediately if it comes to a fire. The system protects you and your property 24 hours a day. Technical parameters: Weight Proteng ENGINE 800 g Weight of the extinguishing agent 500g FM200 (Heptafluoropropane) The material of the detection tube is polyamide Dimensions of the tube: length 210 cm / diameter 18 mm Pressure of natural vapors at 20 C 5 bar Pressure of natural vapors at 100 C 15bar This report consists of eleven pages and may only be used in its entirety. Page 10 / 11

PROTENG AGRO TIR A revolutionary automatic gas extinguishing system that serves the protection of larger enclosed engine rooms for agricultural machinery, buses, trucks and other motor vehicles and machines. On the road every day of the year several cars and other vehicles burn, not only because of an accident, but also often due to a bad technical condition of a vehicle. The Proteng AGRO TIR system is an original automatic extinguishing system that can protect your car from the start of a fire. At the moment of fire, the crew of the vehicle is in direct danger (people can not get out of the vehicle and burns) or one is in shock and acts short-circuited (you do not know how to use a fire extinguisher, the fire extinguisher can not be found, one opens the engine compartment and thereby neither stimulates the fire, it takes too long). Proteng AGRO TIR is installed in the engine compartment and carries out the extinguishing process for you. It is a fully automatic system that does not depend on energy, operation or other aspects and protects you 24 hours a day and not only during driving but also during parking. A big advantage of this system is an exceptionally simple and flexible assembly. The entire working principle is based on one polyamide hose with a diameter of 18 mm and a length of 400 cm in which the effective fire extinguisher FM200, with the exact name heptafluoropropane, is under pressure. At a normal temperature, up to 1000 g of extinguishing agent is stored in this relatively small space, thanks to a pressure of 5 bar. When heating up the environment by fire, the pressure is increased to 15 bar at a temperature of 100 C. The actual start of the system is activated by a temperature above 120 C when the softening polyamide wall of the hose exactly at the location of the highest thermal load bursts and the extinguishing gas is released into the room. This gas reliably and effectively burns the fire in the bud, during the extinguishing no electrical parts are damaged, nor during use. The entire system is fully automatic, requires no operation and starts immediately if it comes to a fire. The system protects you and your property 24 hours a day. Technical parameters: Weight Proteng AGRO TIR 1440 g Weight of the extinguishing agent 1000g FM200 (Heptafluoropropane) The material of the detection tube is polyamide Dimensions of the tube: length 400 cm / diameter 18 mm Pressure of natural vapors at 20 C 5 bar Pressure of natural vapors at 100 C 15bar This report consists of eleven pages and may only be used in its entirety. Page 11 / 11