actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

Similar documents
Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

Indoor/Outdoor Temperature Alert

ATD-3698 Refrigerant Gas Leak Detector. Owner s Manual

Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

USER GUIDE. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester. Model VFM200

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

USER MANUAL Digital CO Monitor Model CO30

LD-5000 REFRIGERANT LEAK DETECTOR

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

testo Leakage detector for refrigerants Bedienungsanleitung Instruction manual

LD900. User Manual. Refrigerant Gas Leak Detector. Detects all HFO, HFC, HCFC, and CFC Refrigerants including blends. Made in U.S.A.

LD920. User Manual. H2/N2 Tracer Gas Leak Detector. Detects 5% H2 in 95% Nitrogen Tracer Gas. Made in U.S.A. LeakDetectors-LD920-UserManual.

CLI Refrigerant Gas Leak Detector. User s Guide

User's Guide. Pinless Moisture Meter. Model MO257

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

TEK-Mate. Refrigerant Leak Detector

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

LD 5000 REFRIGERANT LEAK DETECTOR JB INDUSTRIES INC.

USER GUIDE Heat Index Psychrometer

RD99 REFRIGERANT GAS LEAK DETECTOR WARNING!

Operating Instructions. Model: LD3 Dual Mode Refrigerant Gas Leak Detector ROBINAIR.COM

USER MANUAL USB Multi-Function Datalogger Model RHT35

CD100A COMBUSTIBLE GAS DETECTOR

REFRIGERANT LEAK DETECTOR

SF 6 -Leak Pointer Operating Manual (original version) Type-No.: R002

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

YELLOW JACKET. ACCUPROBE UV and ACCUPROBE II Refrigerant Leak Detector with Heated Sensor. Instruction and Operation Manual

TEK-Mate. Refrigerant Leak Detector

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

Model: LD7 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

D-TEK Select. Refrigerant Leak Detector

User Manual SF6 GASCHECK 6000

RLD-H10P Refrigerant Leak Detector

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

I/R Thermometer Gun 12:1

62 MAX/62 MAX + Infrared Thermometer. Users Manual

Refrigerant Leak Detector

99 Washington Street Melrose, MA Phone Toll Free Visit us at

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

LS1. Operator Manual. Kane International Ltd

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Wake-up Vibration Alarm Model : VR101. User Manual

Mold Alert... Operation Manual P0270

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

TOOLS AND INSTRUMENTS

IRT2 Dual Laser IR Thermometer - User Guide

testo Leakage detector for gas Instruction manual

GasAlertMicroClip X3 Specifications

REFRIGERANT LEAK DETECTOR OPERATIONS MANUAL LD-170

testo 316-EX gas leak detector Instruction manual

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Combustible Gas Leak Detector Instruction Manual

Dual Laser InfraRed (IR) Thermometer

RLD-H10G Refrigerant Leak Detectors

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

MT4 MAX/MT4 MAX + Infrared Thermometer

SENSIT HXG-2d Combustible Gas Detector

NGD8800 USER S MANUAL

AlcoBlow. User Handbook

62 MAX/62 MAX + Infrared Thermometer. Users Manual

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

GERMANY TEC 'LOGY leak-detect EXPERT

62 MAX/62 MAX + Infrared Thermometer

Digital Cooking Thermometer models / 00282

Precision Infrared Thermometer. Users Manual

AG2TEMP PRESTIGE SPECIAL REFRIGERATOR Model: AG2TEMP SPECIAL

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

User's Guide. Pinless Moisture Meter. Model MO257

Users Manual. Air Velocity Meter

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

433 MHz RADIO CONTROLLED PROJECTION ALARM CLOCK Instruction manual

FUNCTION AND CONTROLS

OPERATING INSTRUCTIONS

Air Conditioner. user manual. imagine the possibilities. Wired Remote Control MWR-WH02. This manual is made with 100% recycled paper.

EN Oregon Scientific Radio-Controlled Projection Clock (RM816P / RM816PU / RM816PUL) User Manual

Combustible Gas Leak Detector Instruction Manual

Safe Operation Manual. Honeywell IQ Force Gas Detector

MODEL 951 RADIATION DETECTOR

OPERATING INSTRUCTIONS

Dräger X-am 7000 Multi-Gas Detection

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

HXL. Operating instructions

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Self-learning Room Temperature Controller

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

MW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00

MicroRay IR-100 NEW. Inspection MicroRay IR-100

OILTESTER - Deep-frying Oil Tester. Instruction manual

Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT

MetRad1 Handheld Metal/Gamma Detection Unit. Operation Manual. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963 BNC

Visit us at

KANE-ALERT-CO 2 Monitor with Temperature

Transcription:

Refrigerant Leakage Detector Model RD300 User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector

Safety Please read the following safety information carefully before attempting to operate or service the meter. Only qualified personnel should attempt repairs. Safety symbols CE Certification This instrument complies with the following standards: EN61326 Electrical equipment for measurement, control and laboratory use equipment EMC test. IEC61000 4 2 ESD immunity test IEC61000 4 3 Radiated, radio frequency, electromagnetic field, immunity test IEC61000 4 8 Power frequency magnetic field immunity test Be sure to follow the safety points below. Failure to do so could cause personal injury or damage to the meter. Please read this manual carefully to ensure safe and correct use of this meter before using. Do not attempt to repair this device; only qualified personnel should repair this device. Do not force the flexible tube to bend over its angle limit. Doing so can damage the device. Do not subject the probe tip to shock or severe vibration. Do not use this device near fire or in flammable/explosive environments. Do not use this device in ambient conditions outside of the following limits: 0 C to 50 C (32 to 122 o F). Never use organic solvents to clean the meter 2

Introduction Congratulations on your purchase of the Extech RD300 Leakage Detector. This handheld meter measures leakage from air conditioning or cooling systems that use refrigerant. The LED work lights allow for viewing in dark or dimly lit environments. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website to check for the latest version of this User Guide, Product Updates, and Customer Support. Features Detects all existing refrigerants using a heated diode sensor LED work lights with on/off switch to allow viewing in dark environments High/Medium/Low color coded LED indication with sensitivity of 0.25 oz./year Audible and visual alerts with mute button Low battery indication Field replacement sensor and LED work light tip Meter Description 1. ON/OFF button (hold for 2 seconds) 2. Color coded LED Level Indicators (bottom LED indicates power on) 3. Reset button 4. LED work light on/off button 5. Probe tip sensor 6. LED work light 7. Sensitivity Range select button 8. Mute sound button 9. Loudspeaker 10. Low battery, Mute, and Reset status lights 11. High, Med, and Low sensitivity indicators 12. Flexible probe 1 2 3 4 12 11 10 8 9 7 5 6 3

Operation 1. Power Button: Press and hold the power button for 2 seconds to turn power ON. All LEDs will light and the start up tone will sound. Press and hold power button for 2 seconds to turn off the meter. Check the battery if the meter does not switch ON. 2. Warm Up: The detector will automatically start heating the sensor after power on. During the 90 second warm up, the Leak Level LEDs and Power LED will be lit in cyclic fashion and the meter. After the warm up, the audible tone will sound and the Power LED will remain lit. At this time the detector is ready to find leaks. 3. Sensitivity Range Button: Press the Sensitivity Range button to change sensitivity levels. The High, medium, or low LED will light depending upon the user s selection. The detector will automatically default to the previous sensitivity level after warm up. 4. Reset Button: Press the 'R' button once to reset the meter; the reset LED will flash once. 5. Mute button: Press the Mute button to toggle the audio on and off. The mute LED is on when the audio is switched OFF (muted). 6. Tip Work Light LED Button: Press tip light LED button to switch the probe tip work light ON or OFF. 7. Pass the sensor tip near the potential source of leak and gage the meter s response by observing the color coded LEDs. Green LEDs represent the absence of a leak or a very small leak, yellow LEDs represent a moderate leak, and red LEDs represent the detection of a large leak. Probe and LED Work Light Replacement To replace the 3V LED work light or the sensor please refer to the diagram below. Please switch off the detector before removing sensor. Diode sensor tip part number RD300 S. LED work light part number RD300 L. Notes: 1. The life of the sensor is 1 year under normal use; if a sensor is exposed to a 100 ppm refrigerant, the sensitivity characteristics of the sensor may be affected. 2. Make sure there are no water droplets or dust on the surface of the sensor. 4

Maintenance Cleaning 1. Wipe the meter housing with a damp sponge or soft cloth. Use only mild soap and water. 2. Never use organic solvents to clean the meter (such as thinner, benzene, etc.) as they can damage the sensor. Battery Replacement When the low battery LED is lit, the 9V battery must be replaced. 1. The battery compartment is located on the rear of the meter. 2. Open the rear battery cover and replace the battery. 3. Make sure the battery cover is snapped into place securely before operating the meter. Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold. Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end of life devices to a designated collection point for the disposal of electrical and electronic equipment. 5

Specifications General Specifications Detectable Refrigerants Sensor Sensitivity Levels Warm up Time Auto Power OFF Low Battery Indication Power Supply Battery Life Operating Conditions Storage Conditions R 22, R 134a, R 404a, R 410a, and all CFCs, HCFCs and HFCs Heated Diode High 0.25oz/yr (7g/yr) Medium 0.5oz/yr (14g/yr) Flexible Probe Length 450mm (18") Low 0.99oz/yr (28g/yr) 90 seconds Automatic shut off after 10 minutes LOW BATT light switches ON 9V Battery 13 hours of continuous use 0 C to 50 C (32 F to 122 F) <80%RH 10 C to 60 C (14 F to 140 F) <70%RH Dimensions / Weight 184 x 70 x 40 mm (7.2 x 2.8 x 1.6 ) Weight 280g (10.0 oz.) 6