Tstat9. Bacnet Thermostat

Similar documents
AdaptAire. Digital Control System. User Manual. Expert Systems

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet

ExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling

AirTrak. Digital Control System. User Manual. Touchscreen Systems

Feature Summary. I. System

Product Manual SZ2161. Description The SZ2161 is a microprocessor-based controller designed for water source heat pump plant control applications.

Carbon Monoxide Transmitter

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

Networkable Fan Coil Controller Specification and Installation Instructions

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

2017 products.koer.com Page 1 of 14

1.0 Digital Controller

LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls

CLEANROOM MONITOR CR3A Network - Installation Instructions

Bacnet Room Setpoint & Temp Display. Descriptions. Specifications

EC-BOS-602/616 AX Security

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

Danfoss gas detection unit Type GD Heavy Duty

Natural Ventilation Controller with 24vDC drive NVC-1204

I/O ZONE 560/583 USERS GUIDE

Product Manual SZ1022/SZ1031/SZ1035/

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

Laptop / PC Programming Manual

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

APPLICATION DATA SHEET

T600MEP-2 Programmable Economizer Thermostat

Installation, Configuration and User Manual

ENTOUCH ONE USER GUIDE

AHU Control. Operating Instructions V5.00

Reference Guide for Microprocessor Controller

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL

Added password for IP setup page : Password must be in IP format!

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

INSTALLATION & USER MANUAL

T-32-TS Touchscreen Thermostat. Installation Manual

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

Natural Ventilation Controller with 24vDC drive NVC-1204

AdaptAire. Digital Control System. User Manual

CONTENTS. Installation Guide. VT7200 Series

02/11/2015

Touch Screen Room Thermostat with Modbus Communication

Géothermal

Product Manual SZ1009

Process & TeMPerATUre UniversAl input DigiTAl MeTers

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Commercial Touchscreen Thermostat

- Data Brochure tekmarnet 4 Thermostat 542e

TV2 Room Pressure Monitor Quick Start Guide

Reference Guide for Microprocessor Controller

AireLogic. Digital Control System. User Manual

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

AK-CS On Board Guide

CLEVER CONTROL Version: V3

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

BAC-4000 Series AppStat

Accuracy by Design Products for the HVAC Professional

Digital Thermostat Models: VS30W and VS30B

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

Different types of Fire Alarm System

SE7200 Series Installation Guide

Reference Guide for Microprocessor Controller

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Lift Station Level Controller

Fan Coil Unit (FCU) Application Guide

Installation and Maintenance Manual IM

Smart thermostat with Humidification/De-humidification control

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide. SE8600 Series Room Controllers

LCF Touch Modbus Datasheet Application Security Advice Caution

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat

AK SM 800 Commissioning Guide

4 Wiring Brochure Wiring and

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

TB7300 Series Communicating Fan Coil Thermostats 24 VAC/FOR COMMERCIAL AND LODGING HVAC APPLICATIONS

Manual Supplement. Model Number: 8680-N2. Communications Protocol. Contents of this manual supplement include:

HAI Omni-Bus Network Installation. 5. Typical Application

SYSTEM 2500 PROGRAMMABLE CONTROLLER -USER MANUAL-

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0

Installation Manual for Hot Yoga Studio Electric Radiant Heating

Control manual. Series. Gas-fired direct vent Cast iron boilers. Control adjustment and Operation instructions

Corrigo E. Second generation which contains all applications and languages

Variable Frequency Drive SERIES MP800 VFD

Building Automation System

MC4000 Series Advanced Solid State Dual Unit Lead/Lag Controller with Ethernet Remote Communication Option

EL-TSTAT-8820 Safety & Installation Instructions

Temperature Controllers

OVEN INDUSTRIES, INC.

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS

H&T Household Thermostat Design Introduction

Analog Room Pressure Monitor RPC Series

Installation, Service, and Troubleshooting Instructions

Transcription:

Tstat9 Bacnet Thermostat This full-featured thermostat is designed for cooling and heating systems in residential and commercial buildings.the thermostat can be configured for or use with air handlers,fan coils,vav,modulating valves and practically any HVAC application.all models support bacnet and modbus protocol which allows easy integration with the big name control systems like Niagara, Siemens,Honeywell.Johnson Controls,Delta,Reliable and Kreuter to name a few There are five relays outputs.these outputs can be configured using the free software.there are more than 300 settings with many options for each of the settings so its possible to configure these devices for most any application.once the unit is configured,save the config file for copying to other controllers and backing up project settings. Options are available for occupancy sensor,wifi,and humidity/enthalpy Tstat 9 derivative products have light sensor function by default except for basic Tstat9 Highlights Modbus TCP/IP protocols over WIFI. Well documented register list for easy integration with other systems. 5 relay outputs, each rated at 100~220V, 5 amps. Color LCD display Easily configure the thermostat for practically any application. Clock with infinite life supercap battery backup. Uses 32 bit Arm CPU with 12 bit analog readings. Fits in regular 3in*3in*1.4in(88mm*88mm*35mm) electrical box Typical Application HEAT PUMP FAN COIL AIR HANDLER WIFI Internet PUMP MODULATING VALVES REMOTE USERS MODULATING DAMPERS 01

Tstat9 Bacnet Thermostat Specifications Size Outputs Operating range Supply voltage Power consumption Relay contacts Plastic Housing Enclosure rating Protocols Temperature sensor 5 relay outputs -30~70 C(-22~158 F) / 0 to 99% RH 100~220VAC, 50-60Hz 200mA 5 relays, 5A @ 220VAC Flammability rating UL 94 file E56070 IP31 Modbus TCP/IP 10K thermistor ±0.5 C 63 mm Setup Software Free, no licensing, open source 86 mm Wiring Diagram TSTAT 9 TERMINALS POWER 1 2 110~220VAC NEUT K1 K2 K3 K4 K5 3 4 5 6 7 FAN LOW FAN MED FAN HIGH COOL HEAT Fan COOL HEAT 02

Tstat9 Bacnet Thermostat Approvals Software Plastic Enclosure PA66 UL 94 V0 file 5 digital outputs Highlights PCB E56070 FR-4 Epoxy Glass Cloth UL E479892 Terminal Block PA66 UL 94V-0 Industry standard Modbus protocols User screen displays Day at home, work time, night at home, sleep, holiday 3 PID controllers Bacnet Objects spare spare 03

Tstat9 Bacnet Thermostat Part Number Scheme SET Tstat9 H Code Code Tstat9 Thermostat Code Code H Humidity O Occupancy sensor H-WIFI Humidity-WIFI WIFI WIFI Advanced Menu Item Details They have several advanced menu items which can be adjusted in the field to suit the application and tune the operation of the thermostat. Generally speaking, all the parameters are set up at the factory on an order-by-order basis and will give satisfactory results out of the box. Last menu item Increase value Decrease value Next menu item Day/Night Occupied/Unoccupied Cooling/Heating Actual temp display Fan 04

LCD Screen Display Occupied 1.When you press or, it will decrease or increase Time the 00:16 set point value. The value will flash two times, then it will confirm the setting automaticlly. 2016.09.07 3:50 PM SET 17 FAN SYS Tstat9 Bacnet Thermostat 2016.09.07 3:50 PM 28.9 SET 17 FAN Auto SYS Heat C Occupied Time 00:16 2016.09.07 3:50 PM 28.9 SET 20 FAN Auto SYS Heat C Occupied Time 00:16 2016.09.07 3:50 PM 28.9 SET 14 FAN Auto SYS Heat C Occupied Time 00:16 2.In the normal mode, press both and at the same time.hold for several seconds,it will switch to the menu mode. Press or to scroll through the menu options such as 'Add', 'CAL', 'bau', 'UNITS' and many others. To change the values at a particular menu, press or,the chosen value will be stored automatically. To change the unit's address,scroll through the menu until you reach 'Add'. Press or to increase or decrease the unit's address from 1 to 254. 64.5 28.9 Add 254 C 28.9 C CAL 13.1 64.5 28.9 C C_F -C- 05

T3000 Operation stat9 Bacnet Thermostat 1.Connect Tstat9 to PC by RS485, start T3000 software Click to scan Click to close 2.Click the button to scan, the following view will appear and close it as the picture indicates.when discussing Tstat9,close the view. Tstat9 detected Click to close when discussingtstat9 06

stat9 Bacnet Thermostat T3000 Operation 3.Click Tstat9 log,then click input choices,click as below.,the T3000 will show all the information of it.to change name or Click to show input information Press range to different choices Click to change the name Tstst9 log 4.Click TSTAT9 to do settings,you can see a tab below about setpoint and temperature. Click to do settings 07

stat9 Bacnet Thermostat T3000 Operation 5.Click to do settings,you can see a tab below about parameter.click PIDs tables,you can find PIDs set Dialog. Click to do settings 9 TSTAT9 08

Tstat9-OCC The fan Angle is 60 degrees and the range is about 3 meters Detecting Area View: stat9 Bacnet Thermostat 09