A New Standard of Excellence

Similar documents
THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

Model D12-IR. Digital Gas Transmitter...

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Series 9000 Total Hydrocarbon Analyzer

Transmitter OCX 4400 THE LATEST BREAKTHROUGH FOR COMBUSTION FLUE GAS ANALYSIS. Product Data Sheet PDS A01 February, 2001

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

APPLICATION DATA SHEET

Zircomat Oxygen Analyzers

Dependable Solutions for Gas Detection

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Autronica Fire and Security AS ID:

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

APPLICATION DATA SHEET

Honeywell SLATE ICM Platform

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

continuous emissions monitoring Combustion & Environmental Monitoring

Labkotec Ice Detector

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Chillgard Refrigerant Monitor

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Hydrazine Analyzer Series 2171 Specifications

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

Process Gas Chromatograph

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

Numerical Standards Listing

Series 5000 Hydrazine Analyzer Model 60002

Industrial Grade Gas Detection Detecting The Difference

Low Temperature Zirconia Oxygen Analyzer

Numerical Standards Listing

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Dräger Polytron 7000 Fixed gas detector

HAWK INTEGRATED BOILER CONTROL SYSTEM

STEAMPAK Series BurnerPAK BMS Burner Management Systems

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Two-Channel Gas Controller

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

GasGard 100 Control System

MSA Fixed Gas & Flame Detection for the Automotive Industry

SECTION Fluorescent Dissolved Oxygen Measuring System

Power Flame Incorporated

Temperature Solutions Line Card

Temperature Controllers

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

Power Flame Incorporated

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

PURCHASING SECTION th Street, Surrey, B.C. V3S 3C7 Tel: Fax: ADDENDUM NO.

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

HIGH CAPACITY PRODUCT LINE

HFID Heated Total Hydrocarbon Analyzer Module

Model Q45P/R. ph/orp Monitor...

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

Heating Cable. Description

SUPREMATouch. Modular Fire & Gas Detection System

SPOT HIGH PRECISION PYROMETERS A PRODUCT OF THE SYSTEM 5 FAMILY. 50 to 1800 C / 122 to 3272 F QUALITY CUSTOMER SOLUTIONS

Mercury Vapor Monitor VM-3000

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Drawing Submittal Package

SUPREMATouch Modular Fire & Gas Detection System

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Industrial Grade Gas Detection

The Platinum Bullet - ORP. 546 In-Line Submersible. 547 Ball Valve Insertion Assembly. The Pressure Monster. Electrode & Tip Protection Options

S5000 Gas Monitor. GMS5000.com

SUPREMATouch. Modular Fire & Gas Detection System

HIGH CAPACITY PRODUCT LINE

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Zirconia Oxygen Probe

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

VM-3000 Mercury Vapor Monitor

Model Q45P/R. ph/orp Monitor...

Industrial Grade Gas Detection

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

BC3250. Blowdown Controller

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

AS950 REFRIGERATED SAMPLERS

Refer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System.

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

GAS MONITOR Model Model

YOUR PARTNER IN FIRE & GAS DETECTION

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

For Complete Fire and Gas Solutions

Transcription:

A New Standard of Excellence

PREVENTION IS SO EASY... LIVING THROUGH A DISASTER IS NOT The reliable identification of low combustion oxygen in a fired heater or boiler has always been critical to the effectiveness of the Burner Management System for proper control and safety. Low emission burners and aggressive firing control points to achieve increased efficiency and emission reductions have driven the industry to tighter control measures. But tighter control measures also hold a greater potential for combustion damage. Reducing the risk of a combustion event has become a priority and has led to the implementation of Safety Instrumented Systems (SIS). This additional layer of safety is added to the Basic Process Control System. The WDG-V has been designed to provide an additional layer of safety with the measurement of excess O 2, Combustibles and Methane. These measurements are used to ensure the safe operation of the Burner Management System. The WDG-V Combustion Analyzer is designed to provide the complete solution for combustion process control and process control safety applications. The WDG-V Combustion Analyzer has built-in redundancy and diagnostics to monitor performance and health as well as provide the statistical data needed to implement predictive and proactive maintenance programs. In control and safety applications, it is critical that the analyzer is always operational. Precise control of low O 2 setpoints with confidence CO detection for control interlocks and safety shutdown Predictive diagnostics SIL 2 capable for SIS implementation of IEC 61508/61511 into the burner management system

In WDG-V COMBUSTION ANALYZER SYSTEM WDG-V COMBUSTION ANALYZER SENSOR RANGES: O 2 0-1% to 0-100% COMBUSTIBLES 0-1000ppm with overrange 0-2000ppm to 0-5% HYDROCARBONS 0-1% to 0-5% RESPONSE: O 2 90% < 11sec with Flame Arrestors ANALOG OUTPUT: (3) 4-20 ma ALARM OUTPUT: (5) Dry Contact PROCESS CONNECTION: 2, 3 or 4 Flange AMBIENT TEMPERATURE: -25 C to 65 C DIGITAL INTERFACE: MODBUS RTU, Configuration Software ENCLOSURE: Class I, Div II, Gp B, C, D / ATEX Zone 2, T3, IP65 POWER REQUIREMENT: 115 VAC, ±10%, 47-63 Hz, 740 VA 230 VAC, ±10%, 47-63 Hz DIMENSIONS (LxWxD): 44.45 x 31.75 x 19.8 cm (17.5 x 12.5 x 7.8 ) WEIGHT: 20 kg (44 lbs.) AMEVISION HMI COMMUNICATION: 2 Wire MODBUS DISPLAY: 4.2 Color 1/4W VGA with GUI KEYPAD: Alpha Numeric Membrane ENCLOSURE: Div 2, Zone 2, IP65 (NEMA 4X) POWER REQUIREMENT: 115 VAC or 230 VAC OUTPUTS: 2 or 4 Wire MODBUS RTU- Configurable, Ethernet-RJ45 connection with Web Server DIMENSIONS (LxWxD): 22.9 x 22.9 x 13.3 cm (9 x 9 x 5.25 ) REMOTE CALIBRATION UNIT (RCU) GAS CAPABLE: Aspirator Air (Span) Optional Span O 2 Zero O 2 Combustible Span Hydrocarbon Span ENCLOSURE: IP65, NEMA 4X Class I, Div 2; ATEX Zone 2 POWER REQUIREMENT: None (Supplied from Analyzer) CONSTRUCTION: 316SS, Hard Piped DIMENSIONS (LxWxD): 26 x 31.2 x 13.3 cm (10.25 x 12.28 x 5.25 )

troduces the Next Generation of # COMPONENT SENSOR ENHANCEMENTS 1 Enclosure The Sensor enclosure size and weight has been reduced by over 30% and features a hinged door IP65 enclosure as standard. Lightweight, high R value blanket insulation inside the enclosure insures sensor temperature stability throughout wide ambient temperature cycles. 2 Sensor Heater Block High output single cartridge heater with improved thermal transfer radiant block maintains internal sensor and enclosure temperature to 235 C with only a 30% duty cycle leaving added capacity for extreme temperature environments. 3 Aspirator Block New Aspirator block design with increased orifice sizes reduce chances of particulate interference. Instrument Air or Nitrogen drive gas consumption is reduced by over 20% while directing more process convective flow to the sensors. Analyzer response time with sensor flame arresters is improved to levels of analyzers without flame arresters installed. 4 Combustible Sensor Combustible and Hydrocarbon detectors are installed in a thermally controlled flow block of substantial mass, independent of enclosure temperature, insuring precise temperature stability of detectors, reducing the effects of thermal drift. 5 Flame Arrestors Flame arrestors are incorporated into the convection flow loop so that they may be inspected or replaced in minutes. An upstream arrestor cartridge installed in the combustible flow sensor block can be inspected or replaced in minutes without disassembly of sensor piping. 6 Flow Sensor A flow sensor is incorporated into the sensor piping to detect and alarm when sensor flow is reduced or stopped to insure the sample transport integrity to the measurement sensors from inlet probe tip to exhaust port. 7 Zirconia Cell Furnace New cell furnace design reduces the size and susceptibility to vibration and environmental effects. Redundant thermocouples for cell temperature measurement improves reliability of the measurement. The re-orientation of the cell furnace parallel to the combustible sensor block efficiently utilizes cell furnace heat for maintaining combustible detector temperature stability. 8 Sensor Terminal Enclosure Modular snap in terminal strips with laser etched labels simplify wire connections. Recessed electronics and bottom conduit connections eliminate problems due to conduit stress, moisture egress, and improve the reliability and integrity of the sensor connection in high radiant heat areas.

Combustion Analyzers DIAGNOSTICS & AMEVISION HMI Sample Flow Verification Calibration History Cell & Detector Trending End of Life Prediction of Zirconium Oxide cell & combustible detector with Warning Stability Indicator during the Calibration Process Analog Output Verification Individual Controls of Analog Outputs, Relays Time Stamped Alarm/ Event Log Trend Data Logging & Access by USB Port Redundant Cell, Enclosure & Electronics Temperature Monitoring AME V ISION Display Unit Interface Enables the convenience of site calibration and communication with the analyzer MODBUS RS485 TCP/IP Ethernet USB Port 4.2 color VGA display

CONFIGURATION 1: SENSOR - STAND ALONE, BPCS OR LOGIC SOLVER COMMUNICATION CONFIGURATION 2: STAND ALONE SENSOR WITH AMEVISION HMI CONFIGURATION 3: MULTI-SENSOR with AMEVISION HMI 150 Freeport Road, Pittsburgh, PA 15238 Ph. +1-412-828-9040, Fax +1-412-826-0399 www.ametekpi.com 2013, by AMETEK, Inc. All rights reserved. Printed in the U.S.A. F-0409 Rev. 3 (1013)