Sneak Preview: Siemens Controller Firmware X.58

Similar documents
Optical Preemption & Priority Control Systems

Web Pages for Construction and Traveler Information Condition Reporting System 511 Phone Power. Data Processing and Response Formulation

SH 242 ADAPTIVE TRAFFIC SIGNAL SYSTEM DEPLOYMENT

Advance Warning Flasher System at High Speed

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

VIDEO CONTROLS LIMITED

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

UDOT AUTOMATED TRAFFIC SIGNAL PERFORMANCE MEASURES

GE Security SAPPHIRE Pro

Section 1. Executive Summary

Table of Contents. Optical Preemption & Priority Control Systems

Ref: March 21, Ms. Jody Kablack Director of Planning and Community Development Town of Sudbury 278 Old Sudbury Road Sudbury, MA 01776

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 6 Code Driving Revised

14 October 10, 2012 Public Hearing APPLICANT: MPB, INC

SEAR II APPLICATION 9V736-A01D PREPARED FOR NORFOLK SOUTHERN

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Optical Preemption & Priority Control Systems

Request for Qualifications. Knowledge Park Pedestrian/Cyclist Connectivity Planning and Design

Executive Summary. NY 7 / NY 2 Corridor

REQUEST FOR QUALIFICATIONS

PHASE NON-COIN USER S MANUAL (S.A.F.E.)

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

BUILDING SECURITY and EVACUATION RELATED POLICIES: REVIEWED: AS NEEDED

COLVER ROAD INDUSTRIAL CONCEPT PLAN

EXHIBIT A. Chapter 2.7 SPECIAL PLANNED DISTRICTS. Article XVIII 15th Street School Master Planned Development

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

Richardson Fire Department 136 N. Greenville Avenue, Richardson, TX Telephone: Fax:

Challenger Series Users Manual

Major Subdivision Sketch Plan Checklist

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

2016 REVISIONS COMMENT FORM RULES AND REGULATIONS FOR CONSTRUCTION IN THE PUBLIC WAY COMMENT PERIOD: JUNE 1 TO JUNE 30, 2015

Patrick County Horizons Jeb Stuart Hwy. Stuart, Va

I.T.S. PLAN ALONG I-95 INSTALL FIBER OPTIC LINE PROJECT SHOWING Tuesday, June 18, 2013, 1:30pm Ashland Residency Conference Room

Uplink Remote Installation Guide 5500EZ

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

F 2 MC-8FX FAMILY MB95200 SERIES SMOKE DETECTOR DEMO REFERENCE SOLUTION 8-BITMICROCONTROLLER APPLICATION NOTE

RE: AMENDMENT C375 GEELONG PLANNING SCHEME 1900 BARWON HEADS ROAD, BARWON HEADS

New requirements for IEC best practice compliance

PHASE III: Reserved Matters Submission

Smoke Detector Demo Reference Solution

2. What is required if I want to put some patio/bistro tables and chairs on the sidewalk and remove them at the end of each day?

Connections, displays and operating elements C D E G H. Installing the control unit

Detailed Instructions

METHOD STATEMENT. Process. Document Authorisation Role Name Function Signed Prepared by:

TAHOE DOUGLAS FIRE PROTECTION DISTRICT JOB DESCRIPTION Fire Inspector Fire Prevention

CITY OF LANGLEY OFFICIAL COMMUNITY PLAN BYLAW, 2005, NO APPENDIX II - REGIONAL CONTEXT MAP

PARKLET PROPOSAL PACKAGE & PROCESS

REVIEW AND EVALUATION OF REGIONAL LAND USE

ELECTION DISTRICT: PRINCESS ANNE

Driver Resource Manual Unit 6 Emergency Evacuation

RAMBLER PARK FIRE SAFETY INFORMATION

PowerRouter application guideline

Evaluation of Strobe Lights in Red Lens of Traffic Signals

Operating principle. Quinto

2. AGENCY COORDINATION AND PUBLIC INVOLVMENT

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Application for Site Plan Review

PLANNING COORDINATING COMMITTEE

AESTHETIC APPEARANCE. Design Guidelines for Grade-Separated Pedestrian, Cyclist and Equestrian Structures

GLD-30 Gas Leak Detector

DETECTING WRONG WAY DRIVERS. Lynne Randolph Southwest Research Institute (210)

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel

Austin Independent School District Police Department Policy and Procedure Manual

TOWN OF BRUDERHEIM Report to the capital region board

MIDTOWN MIXED-USE VILLAGE. TECHNICAL DATA SHEET COMPONENT C-1 FOR PUBLIC HEARING - PETITION NUMBER Project No RZ1.1. Issued.

CBI-064. User Manual. Caddx to KNX-BUS Interface

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

Leonard s Beach Secondary Plan (Alcona North) Official Plan Amendment

Non-Emergency Direct Line Telephone Numbers. Emergency Direct Line Telephone Numbers

The Firefighters Perspective

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

Code Alert Series 30 Software User Guide

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

Interface between proprietary controllers and SUMO

City of Charlottesville

Vehicle Detection. Brief history of each detection. How they work. Discuss most used ones. Are other options

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

HRX Technical Manual. Version 1.2

DIAMOND II. DARM Delayed Alarm Reporting/Masking. Manual Number AV Revision - A.1 September 3, 2004

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

GOODY CLANCY WITH KITTELSON & ASSOCIATES RHODESIDE & HARWELL FARR ASSOCIATES W-ZHA

D3 January 14, 2015 Public Hearing

ARGUS APPLICATION 9V937-A01C

Installation Guide: PowerAire Quad

DS1286 Watchdog Timekeeper

DAVENPORT VILLAGE SECONDARY PLAN

Background information

BROOKHILL NEIGHBORHOOD MODEL ZONING MAP AMENDMENT PREFACE TO APPLICATION

Yonge-Summerhill: Urban Square Design (Midtown)

OVERMOUNTAIN VICTORY TRAIL BURKE CALDELL CORRIDOR FEASIBLITY STUDY REQUEST FOR QUALIFICATIONS CALDWELL COUNTY PATHWAYS

The transportation system in a community is an

Declaration of Conformity no. 56/2012

Request Conditional Rezoning (R-15 Residential to Conditional A-24 Apartment) Staff Recommendation Approval. Staff Planner Jimmy McNamara

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

Welcome to smarter living. New Resident User Guide

DXL ALA Settings Guide

Bypass #16 - Bend Parkway (new alignment for US 97) (MP )

Humidifi er FAQ. Why is the humidifier not running? The following conditions need to be satisfied before the humidifier sequence can start:

Transcription:

2017 Sneak Preview: Siemens Controller Firmware X.58 Siemens Traffic Controller firmware 3.58 ad 4.58 will be available in May of 2017. Here are some of the new features. - Michael Grunewald, PE, PTOE Advanced Traffic Systems Manager MoboTrex March 14, 2107

Sneak Preview Siemens Firmware X.58 Siemens has defined a firm controller firmware update schedule. A new firmware set will be released each spring. A maintenance release for the new firmware will be released each quarter. The next firmware release X.58 (3.58 [ECOM version] and 4.58 [NTCIP version]) will be available in May of 2017. The following are some of the benefits of the Siemens X.58 Firmware Set? 1. Emergency Vehicle Preemption Coordinated Operation during Preemption Consider a railroad preemption scenario. The train is sitting on the tracks for a long time. With X.58 firmware, the traffic signal returns to coordinated operation during the Dwell/Cycle Interval of preemption with the train still present. This will be a substantial improvement in applications involving a railroad track running parallel to a busy arterial. 2. Emergency Vehicle Preemption Get Back to Coordination Plan faster Do you have a critical intersection that is regularly interrupted by emergency vehicle preemption? X.58 firmware will maintain the traffic signal coordination timer operating continually in the background, rather than turned off as the coordination timer had been in earlier firmware versions. X.58 firmware will exit from the preemption routine directly into the active coordination phase window running in the background. Prior to X.58, the intersection typically took four to five phase cycles to get back into step with the coordination plan (typically ten minutes). With X.58, the preempt routine can exit directly to the open, active coordination window (immediate return to the active phase window of the coordination plan). When the preempt demand exits bam! Immediately back to running the coordination plan for the intersection. 3. Service Emergency Vehicles more quickly Prior to servicing the emergency vehicle preemption, do you require that the active pedestrian flashing Don t Walk clear normally or in part? In X.58 firmware we have the capability of choosing to push the pedestrian clearance of the exiting signal display through all or a portion of the vehicle Page 2 of 7

clearance times (yellow and all red). Thus we can rotate the green more quickly to the preemption vehicle and still maintain the minimum clearances we believe favor safe transitions. 4. Improve Side Street Operation in evening plans Does your 8-phase intersection maintain a coordinated plan in the evening hours? A common concern is when a lone vehicle enters the left turn lane on the side road and it is required to wait an extended period of time to get a green light. What may have happened is that the controller closed the left turn green window just before the vehicle arrived. A green window remains open for the side road through, but no longer for the side road left turn phase. X.58 firmware adds the capability for calling any phase combination from any detector channel. You now have the ability for the side road protected-permissive left turn detector channel to call to the through phase and the left turn phase at the same time. Give that night-time driver a faster green ball to reduce a potential complaint. 5. Crossing Guard Walk and Flashing Don t Walk Timing Do you have an intersection where a crossing guard helps children cross? You now have the option to program two phase banks in the controller. Program Phase Bank 1 to include normal pedestrian timing that will work well for one or two pedestrians demanding a Walk signal. Program Phase Bank 2 to include special pedestrian timing longer crossing times called by time-of-day command that allow the crossing guard extra time to safely cross the children. 6. Substitute the Siemens Traffic Signal Controller for any NEMA controller Even with FYA When Flashing Yellow Arrow control was authorized in the MUTCD, each controller manufacturer defined their own input/output control for FYA support in their traffic signal controller cabinet. In X.58 firmware, Siemens has made their controller input/output file so flexible that the Siemens controller can now be programmed to support any manufacturer s cabinet setup including their FYA support. 7. Locking Detectors on Non-Locking Phases Bike Detectors Some of our customers have been asking for Locking Bike Detectors on non-locking detection phases. The X.58 firmware will now allow the user to define any of the controller s 80 detector channels as a locking detector. So the user can designate a phase as non-locking and overlay any Page 3 of 7

number of detector channels onto a phase. Some of those detector channels may be locking while others are non-locking. The choice is yours. 8. Slick Detector Diagnostics The Siemens controller has long had detector diagnostics the controller monitors detector inputs and qualifies them as valid or failed. Siemens has already had two detector diagnostics plans a daytime plan and a night time plan. Many customers expressed concern that the response to a detector that was listed as failed constant detector call was too harsh and created unnecessary maintenance responses. Therefore customers did not use detector diagnostics very often. In X.58, the detector diagnostics fail response is a user decision - from Max call to no call for a failed detector. In between, the user can define the form of controller-generated call to the phase (for how many seconds during the green phase?). So detector diagnostics should be something the customer always uses! Monitor detector health; respond at the level you deem helpful for a failed detector condition. New Features of SEPAC X.58 Here is a list of some of the new features available in X.58. 1. Phase Data a. Adds a Phase Bank Copy Function b. Places Dynamic Max into Phase Data Menu easy to use c. Large changes in detector section i. All choices for a detector channel placed onto a single screen ii. Each detector channel can call to any and all phases 1 to 16 at the same time. iii. Locking detectors 1. User can specify a non-locking phase, as usual 2. User can then pick individual detector channels that place locking calls to non-locking phases. iv. Detector Diagnostics Revised. 1. User defines the level of the constant call for a failed detector a. Constant call as original b. No call to a failed detector c. Call for a defined number of seconds while phase is green v. Additional Queue Detector option vi. Define detector channels that contribute to Added Initial for the phase 2. Unit Data a. Revised Overlaps i. Now easier to define 1. Flashing Yellow Arrow overlap 2. Standard overlap Page 4 of 7

3. Pedestrian overlap 4. Trailing overlap b. Flexible Channel Output Mapping i. Can assign outputs from phases, overlap, etc. to any loadswitch pin on the backpanel ii. Works with any NEMA controller backpanel iii. You can replace any manufacturer s controller with the SIEMENS controller even FYA formats which are manufacturer specific. c. Peer-to-Peer input/response control i. Define if-then statements ii. If this happens at controller A, then this occurs at controller B d. Unit Data Banks i. Similar to Phase Banks in Phase data ii. User can swap out Unit data sets on the fly by time-base or peer-to-peer control iii. Allows changing peer-to-peer plan by time of day or active conditions 3. Preemption Data a. Adds field for user to define any one of 6 preemption detectors and 80 vehicle detector channels to call the preempt routine b. Adds option to define how the flashing Don t Walk of the select interval exits for each preemption routine gets to preemption vehicle earlier. i. FDW ends at end of green ii. At end of yellow iii. At end of red iv. With minimum MUTCD Buffer interval c. Coordinator stays alive during preemption i. Faster return to coordinated operation ii. Begin coordination reorganization immediately upon preempt exit d. If Dwell interval operates as CYCLE i. Controller operates in the active coordination plan during CYCLE ii. Controller still ignores the phases the user excludes during the Dwell/Cycle interval iii. An arterial parallel to a railroad track can operate normally while a train parks, blocking the track leg. Page 5 of 7

e. Exit to Coordination plan no transition needed. i. User must specify no exit phases for the preemption Exit interval. ii. Upon preemption call ending, controller chooses the next open coordination window. Controller chooses those phases next. f. Left turn Trap Protection for Five-section Lefts and FYA lefts during Preemption interval transition. [SRMOD feature] g. Increases the number of preemption routines from 6 to 12 h. Re-orders preemption routines so preempt # is menu # for easier programming 4. Priority data a. 4 Priority Banks activated by time of day or peer-to-peer control b. Increases the number of preemption routines from 6 to 24 Page 6 of 7

Conclusion X.58 includes many new features newest Siemens firmware set. The new firmware will operate on existing M52 controllers and Siemens M60 controller firmware. If you have interest in utilizing the new firmware for an existing controller, MoboTrex can quote you small volume pricing. If you would want to upgrade all of your existing controllers, Siemens offers annual service agreements to cover firmware upgrades for all traffic signal controllers in your entire agency at a reduced unit cost. We invite you to call your regional sales rep or the Davenport office @ (563) 323-0009. Page 7 of 7