Flashing Lights Controller: BSU 10x/20x/S

Similar documents
Instructions for the fan motor control system, SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Original operating instructions Safety switch with guard locking AC901S AC902S

FWC860 Wine Cooler Installation, Use and Maintenance

fwc152 / fwc303 / fwc603 / fwc623 Wine Coolers Manual for Installation, Use and Maintenance

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

USER MANUAL AND TECHNICAL MANUAL

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

VA301C CONTROLLER WITH BACnet OPTION

FWC153, FWC304, FWC604 & FWC624

FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers

RE-PR3-E-27 3-Phase Panel Mount 27kW

FWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance

CP-200 Push Button. CP Warewash Pump Instruction & Operation Manual Push Button , Rev1.0,

Owner & Operator s Manual. Table of Contents

Flow Factor ~

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

Installation and user manual for the BiWire / Conventional Repeater Panel

Operating Instructions!

Preamplifier Power Supply PPS-02 user's guide

APC BC300 Series 40kW 208/450/480V User Guide

Emergency power automatics MS-2. High resistance to shock, vibrations and transients. All output are 2A relay contacts

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Built-in ceramic-glass cooktop

compact office 24V compact office 24V Lux

52 CEILING FAN. Owner s Manual Models #50336, 50337

INSTRUCTIONS. MODEL: CPC and CPC1 PIE CABINETS

Operator's Manual. LIGHTNING 2 Laser Detector

CRU-S Series Stainless Steel Condensate Recovery Unit

52 BERKSHIRE CEILING FAN

Push Button Electronic Timer. 31VETR Series. Installation Instructions

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

ICE MAKER. Model: IM-101 INSTRUCTION MANUAL

SERIES 4000 AUTO GATE MANUAL

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

INSTALLATION FB T: +44 (0) F: +44 (0) E: W:

Operation Manual for Drying Storage Cabinet with Drying Unit U-5002

PCR-300 PCR-300 RC. Installation and Operating Instructions

HSGM Heißschneide-Geräte

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

NoZone Ozone Scrubber

Installation and Programming manual INSTALLATION MANUAL E PROGRAMMING INSTALLAZIONE PROGRAMMAZIONE

Popcorn Warmer Cabinet

26 FIREBOX EN RU UA FR

PORTABLE ICE MAKER. Model: IM-124S INSTRUCTION MANUAL

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

SACE PR021/K SIGNALLING UNIT

USE AND INSTALLATION HANDBOOK

FLEXIT S4 X/TT - A4 X/TT S7 X/TT - A7 X/TT

LC3000 Level Controller Installation and Maintenance Instructions

FF820 Freestanding Full Height Larder Fridge Manual for Installation, Use and Maintenance

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

USER MANUAL CEF AP28 CONTROL PANEL

CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

4) Intrinsic Safety Certification

Operations Manual DS 220. Docking Station for Micro IV

Motorised swing doors User manual (translation of the original instructions) IP2225EN

Ceiling Mount Air Purification System

compact office 24V compact office 24V Lux

Whole Room Dryer WRD, WRD/110

Mark 25 Ultrapure Water Conductivity Analyzer

SMART Electronic control for towel radiators

Alarm Switchgear AS1-M

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Operating Manual. VIENNA Hot Display

Stripping machine AI 01

MENU. Steamist Digital Sauna Control Models: S170-1 and S Steamist Digital Sauna Control. Contents. 1. Steamist Digital Sauna Control

CP-200 S&T. CP Warewash Pump Instruction & Operation Manual Speed & Time , Rev1.0, , Page 1 of 8

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

C-Bus Four Channel General Input Unit Installation Instructions

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

INSTRUCTIONS NACHO WARMER MODELS: 1995 / 1995S

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

5, SE GÅNGHESTER,

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

HR 601 C A AUS. ENGLISH Instructions for use Page 2

Power Conditioners User s Manual. For use with Standard Power Conditioners, Medical Power Conditioners and Ground Guard Power Conditioners

GB Operating instructions

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

NXM2G Installation and Operating Manual

IH 025 VOLCANO. Portable Induction Heater. smart mounting

LC2200 Level Controller Installation and Maintenance Instructions

Electronic Temperature Controller 70304,

Test Lamp for 210 series flame detectors Non EX

Instructions For Use ENG. LED Magnifier Lamp

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

NRB100. Installation and Programming Manual INSTALLATION NRB100 AND PROGRAMMING MANUAL

ISCG90SS _03 ISCG90SS

INSTRUCTION MANUAL (ATEX)

Transcription:

ELECTRONICS RESEARCH DEVELOPMENT Operating Manual Flashing Lights Controller: BSU 10x/20x/S Litostrojska cesta 44/d, SI-1000 Ljubljana T +386 (1) 514 18 00, F +386 (1) 514 18 04 info@itaia.si, www.itaia.si

Table of Contents 1 Safety Information and Caution... 1 1. 1. General... 1 1. 2. Safety Precautions... 1 2 Guideline for Connection and Use... 3 2. 1. Field of Use... 3 2. 2. Connecting the Controller... 3 2. 3. Indications and Management... 4 2. 3. 1. Synchronization... 5 2. 4. Instructions for Safe and Proper Use... 5 3 Maintenance... 6 3. 1. Checking and Maintenance... 6 3. 2. Servicing... 6 3. 3. Troubleshooting... 6 3. 4. Spare Parts... 7 4 Technical Specifications... 7 4. 1. Environmental Conditions... 7 4. 2. Transport and Stocking... 8 4. 3. Disposal... 8 5 CE Declaration of Conformity... 8

1 Safety Information and Caution 1. 1. General The device, connected and used in accordance with following instructions, is safe to use. All electrical parts are protected against water, dust and dirt by the relevant IP class. Housing prevents direct contact with any parts under voltage. Connection of the device must be done in accordance with local standards. Prior to commission control measurements must be preformed to ensure safe and correct operation.!! CAUTION: For any injury resulting from improper use, the user takes full responsibility. BEFORE MOUNTING AND CONNECTION READ THIS MANUAL CAREFULLY! THE CONNECTION OF DEVICE MUST BE DONE BY QUALIFIED PERSONNEL! PRIOR TO CONNECTION, UNPUG ELECTRICAL POWER! DO NOT BLOCK ACCESS TO ELECTRICAL PARTS USED FOR EMERGENCY STOP, CLEANING AND MAINTENANCE! METAL PARTS OF THE HOUSING MUST BE GROUNDED! MAKE SURE NO WATER GETS IN TOUCH WITH PARTS UNDER VOLTAGE! Fire-extinguishing Gear In case of fire use CO 2 based fire extinguisher and other equipment following procedures in accordance with fire-safety regulations. 1. 2. Safety Precautions Safety precautions provide personal safety and long service life of the device. Any person taking part in mounting, connecting or maintaining the device must follow this manual and local safety regulation. Page 1 of 10

Before starting: Disconnect circuit breakers at input and output of the device and make sure there is no voltage present. Make sure power stays disconnected during the time of mounting and connecting. Take special care when working on a device installed in areas with high-voltage present. Check grounding connection. Provide protection against touching the parts under voltage. Technical Support Litostrojska cesta 44/d, SI-1000 Ljubljana T +386 (1) 514 18 00, F +386 (1) 514 18 04 info@itaia.si, www.itaia.si In case of malfunction please provide us with following information: type of the device, serial number, errors detected, overall time of operation, environmental conditions and application information. We take no responsibility for proper operation and any consequence resulting from use in discordance with this manual. Safety measures must be provided by user working with the device. Declaration of Conformity The device complies with relevant European directives (CE declaration of conformity): Electromagnetic compatibility (ULRS, no. 132/2006) Directive 2004/108/EC and its amendments Low voltage Directive (ULRS, no. 27/04) Directive 2006/95/EC and its amendments Page 2 of 10

2 Guideline for Connection and Use 2. 1. Field of Use Flashing lights controller type BSU xxx/s is designed to control flashing yellow traffic light at toll stations, border crossings, pedestrian crossings, railway crossings, etc. Flashing frequency is adjustable. LED indicator shows the operation of the controller. Synchronization in phase or antiphase enables simultaneous control of multiple lights, even at different phases of power supply, or alignment with external flashing rhythm. BSU xx2 model combines outputs which flash alternately (used for pedestrian crossing, level crossing). The switching system is the so-called zero-cross, which switches on/off at zero voltage to prevent any disturbing emissions to the power line. The bracket is designed for mounting on a DIN mounting rail. 2. 2. Connecting the Controller Mount the controller away from any heat sources, water or dirt. Proper ventilation must be ensured in the room to enable extraction of the resulting heat. When mounting and using the controller make sure that inside there are no foreign objects, which could cause a short circuit. The controller is powered from the mains voltage 230 V AC. Typical connection depending on the method of application is shown in Picture 1 and Picture 2. Picture 1: Connecting the BSU xx1-s controller Page 3 of 10

Picture 2: Connecting the BSU xx2-s controller (flashing alternately) 2. 3. Indications and Management LED indicator displays the status of exit 1, which operates synchronized in phase. Choose the frequency in range of 0,3 2,5 Hz with γ trimmer. At the connection terminal there is a fuse which protects the controller and the connected lights. In case of a blown fuse always replace it with a new one of the same value and type. Picture 3: LED indicator and frequency setting Page 4 of 10

2. 3. 1. Synchronization Multiple controllers type BSU xxx-s are connected to each other via a synchronization port. This ensures coordinated flashing of all connected lights. This is particularly beneficial when we have to use power supply of different phases due to a larger number of lights. Simultaneous (in phase) or alternate (in antiphase) flashing of the lights can be achieved with synchronization. The synchronization port can be used also for controlling the activation of the device or for synchronizing the controller with the flashing rate of other devices in the system (e.g. in a tunnel). The method of connecting is shown in Picture 4. FROM PREVIOUS or 1000 Ω Synchronised PHASE TO NEXT BSUxx UNIT EXTERNAL 5V TTL + - Synchronised INVERSE PHASE TOP VIEW IN OUT IN OUT MASTER SLAVE Picture 4: Connection via synchronization port A larger number of flashing lights controllers can be synchronized without noticeable delays. They are synchronized to the first controller in the chain which is connected to the OUT terminal of the synchronization port. All controllers should be set to the same flashing frequency for optimal performance. External synchronization signal: 5mA / 5 V TTL ~ 1000 Ω (3 25 V with a suitable series resistor!); 0,3 to 2,5 Hz; input (IN) is galvanically isolated. 2. 4. Instructions for Safe and Proper Use CAUTION! The housing surface can become very hot when the device is operating. Electrical ground must be connected for all applications. Synchronization port s output is not potential-free. When the synchronization port is not in use, protect the contacts with the rubber cap provided. Page 5 of 10

Incorrectly connecting the synchronization port can cause the destruction of one or more controllers in the branch. 3 Maintenance 3. 1. Checking and Maintenance The device must be regularly visually inspected. Having identified any damage do not use the device and call service. It is recommended to clean the housing occasionally. Note! The device requires regular checks and maintenance. Keep your maintenance and service log up to date. Shorten check intervals if required. Maintenance personnel must be qualified for the job; Maintenance contractor company must provide education and training; Regular testing and checking must be exercised as described in this manual and local standards; Any maintenance activity must be noted in the log. 3. 2. Servicing Servicing can only be done by authorised qualified personnel. Keep a servicing log. Servicing for the time of warranty is provided by manufacturer exclusively. After that time it can be done by an approved maintenance contractor. 3. 3. Troubleshooting Error Possible cause Action There is voltage at the output of the controller, the control LED is not lit. There is NO voltage at the output of the controller, the control LED is flashing. - defective controller - call service - defective controller - call service There is no voltage at the output of the controller, the control LED is not flashing. - blown fuse - voltage at synchronization port - change fuse - check synchronization connection Page 6 of 10

Disproportionate time turning on/off when operating with synchronization. - Natural frequency setting deviates significantly from synchronization frequency - set flashing frequency Do not try to open the device! In case of a faulty device call service! 3. 4. Spare Parts Parts that need to be changed must be replaced with original or functional equivalent parts approved by the manufacturer. 4 Technical Specifications Basic technical data is also visible on a sticker on the photometer. Labelling: BSU x x x S output nominal voltage 1 single-channel design S with synchronization 2 two-channel design with alternating flashing Nominal voltage 240 V AC / 50-60Hz Voltage range 170 250 V AC Flashing frequency 0,3 to 2,5 Hz (0,5 Hz preset) Temperature range -20 C to +50 C Power consumption approximately 0,5 W Housing ABS / Aluminium IP protection IP 20 Dimensions (W x H x D) 50 x 100 x 75 mm Weight 0,230 kg 4. 1. Environmental Conditions Maximum environmental temperature is +50 C. Lowest environmental temperature is 20 C. Ventilation must be ensured to allow the extraction of the resulting heat. Relative air humidity must not exceed 50% at maximum temperature. Higher humidity is allowed at lower temperature (e.g. 95 % at +20 C). Page 7 of 10

Sea-level elevation must not exceed 2000 metres. When using above 1000 metres consider lower air dielectricity and different cooling conditions. 4. 2. Transport and Stocking Transport the device in the original packing if possible. When that is not available use protective air bubble foil and protect exposed areas with Styrofoam. If needed place it on wooden pallets. Temperature while transporting and stocking should be between -25 C and +55 C. Avoid stocking for longer periods of time. After transporting and mounting allow the device at least 1 hour time to settle down before commission. In case that the device is not to be used for a longer period of time, store it in a dry, well ventilated place at room temperature! 4. 3. Disposal Lifetime of the device significantly depends on the way of use, installation, maintenance and working conditions. Production year is visible on the sticker on the back side. Dispose a deteriorated or ruined device to a place for industry electronic-components disposal according to local regulation. Components particularly dangerous for the environment (batteries, chemicals, etc.) should be disposed to special places. 5 CE Declaration of Conformity CE declaration of conformity ensures that the device is safe to use and has been checked and tested to the specified standards. CE statement is enclosed. Page 8 of 10

http://www.itaia.si, info@itaia.si ES - IZJAVA O SKLADNOSTI CE DECLARATION OF CONFORMITY Manufacturer (name, address): Proizvajalec (naziv, naslov): ITAIA d.o.o. Litostrojska 44/d 1000 Ljubljana product: Blink-steering unit proizvod: Utripalni krmilnik We declare under our sole responsibility that s polno odgovornostjo izjavljamo, da (type, model): (tip, model): BSU xx1/2 /S is in conformity with the provisions of the following regulations: ustreza zahtevam naslednjih predpisov: - Low voltage Directive (Uradni list RS, no. 27/04) Low voltage directive 2006/95/EC and its amendments - Electromagnetic compatibility (Uradni list RS, no. 132/2006) EMC directive 2004/108/EC and its amendments and complies with the requirements of the following standards: in izpolnjuje zahteve naslednjih standardov: SIST EN 60335-1:2003 +A11:2004 +A1:2005 SIST EN 60335-2-29:2004 SIST EN 61204:1999 SIST EN 60529:1997 +A1:2000 SIST EN 61204-3:2002 Household and similar electrical appliances-safety-part1 Household and similar electrical appliances-safety-part2 Low-voltage power supply devices, d.c.output-performance characteristics and safety requirements Degrees of protection provided by enclosures Low-voltage power supply devices, d.c.output-part3:emc Year of affixing of CE mark: Leto, ko je bil CE znak nameščen na proizvod: 2008 Peter Strmčnik, direktor Ime in priimek, funkcija Name, surname, position

Limited Warranty Conditions Our products are workmanship and materials fault free and will work according to specification for a minimum time of warranty (1 year). We provide spare parts and servicing for at least 5 additional years. We will respond to failure notice immediately (7 days at maximum) and fix it within 48 working days. During the warranty period we take full responsibility and costs (transport not included) for removal of any malfunction due to faulty materials or workmanship. After this period we charge servicing according to used time and replaced parts. Warranty related obligations come in power with full payment. Warranty obligations cease to exist: in case of improper use or use in discordance to this manual; in case of mechanical damage; in case of consequential damage due to failure or damage of other devices, in case of natural or environmental cause (e.g. lightning discharge, flooding, fire, etc.), if the device has been repaired by unauthorized personnel, if there are unoriginal spare parts built in the device, if there are changes made to the device or their parts without written approval of the manufacturer. Servicing obligations cease to exist: if the device has been ruined, if the device has been repaired by unauthorized personnel, if there are unoriginal spare parts built in the device, if there are changes made to the device or their parts without written approval of the manufacturer, for the time of overdue payment for previous services. Sale Data: Serial number: Page 10 of 10

V 1.2 rev.7.2016

Litostrojska cesta 44/d, SI-1000 Ljubljana T +386 (1) 514 18 00, F +386 (1) 514 18 04 info@itaia.si, www.itaia.si