INSTALLATION, OPERATION AND MAINTENANCE. ARITERM SWEDEN AB Installation, Operation & Maintenance /28

Similar documents
INSTALLATION, OPERATION AND MAINTENANCE. BeQuem 50. ARITERM SWEDEN AB Installation, Operation & Maintenance /20

ARITERM-VTT-S INSTALLATION AND OPERATING INSTRUCTIONS

ARITERM-VTT-S INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm Biomatic+ 20

Operating Instructions Manual Janfire NH/Integral Pellets Burner with External Auger

ARITERM OY. Arimatic 500. User manual

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

PELLET BURNER PV 350

SWEBO Bioenergy Manual pellet burner PB20 Rev no. Date Page PBM1: (36) Installation and maintenance instructions

SWEBO Bioenergy Manual pellet burner PB50 Rev no. Date Page PBM1: (37) Installation and maintenance instructions

5P01781-A 5P01781-B INSTALLATION AND OPERATING INSTRUCTIONS

Operating Instructions Janfire Pellet boiler Integral Typ 25

INSTALLATION AND OPERATING INSTRUCTIONS

Installation, operation and care. Pellmax UB. Burner not included Replaces:

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Pellet burner PV 180a. User manual

TECHNICAL INSTRUCTIONS USE AND MAINTENANCE

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

Operation and maintenance A4 Pellet burner

Main components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens

ARITERM-VTT-S ARITERM-VTT-S ARITERM-VTT-S ARITERM-VTT-S INSTALLATION AND OPERATING INSTRUCTIONS

USE AND MAINTENANCE. Cm Pelet-set (60-90 kw) TECHNICAL INSTRUCTIONS

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

INSTALLATION AND MAINTENANCE INSTRUCTIONS PELLUX PELLUX 100 H AP

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL INSTRUCTIONS. (14-35 kw) For boilers: EKO-CK P (EKO-CK 20-40) EKO-CKB P (EKO-CKB 20-40)

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

PELLUX INSTALLATION AND MAINTENANCE INSTRUCTIONS PELLUX 100 H AP

MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel.

USER MANUAL 9kW LILLY PELLET STOVE

Installation, operation and care Firewood boiler Vedolux 40 UB

Boiler controller S-Tronic Plus

BIX B-One 100 kw INSTALLATION GUIDE

Installation & Maintenance Manual

Pellet heating. Boilers & Burners.

Operating Instructions Manual PellX 20 & 35 kw Pellet Burner with External Auger

Electronic Pellet Burner Controller NPBC-V3M

ST 40 Oil Burner. Installation & Maintenance Manual

- 12, , TECHNICAL INSTRUCTIONS

Solid fuel hot water boiler TKH KW INSTRUCTIONS MANUAL for usage and maintenance

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

Installer manual ELK 213 Immersion heater

eurofire BIG 100, 200, 300 kw

Operating Manual PELLEMATIC PES CMP06 TO_VA6.39 Pelletronic TOUCH ENGLISH. PE 1491 EN_TO 1.0 Europe s specialist in pellet heating

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Boiler controller Lambdatronic S 3200

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 400

Installation and maintenance Viking Bio 35 - pellet burner

Product waste disposal - Protection of the environment:

TECHNICAL AND OPERATIONAL DOCUMENTATION

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

INSTALLATION AND USER INSTRUCTIONS

TABLE OF CONTENTS ARITERM OY bio burners burn back protection arimax bio kw boilers

INSTALLATION AND MAINTENANCE OF. Ulma ECO 2 Premium 30 kw

CentroPelet ZV14 TECHNICAL INSTRUCTIONS HEATING TECHNIQUE. for regulation, use and maintenance of pellet stove

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A

TERMO-Blok TERMO-Extra TERMO-Blok PTV TERMO-Mini

User s Information Manual

WHE 2.24 / WHE 2.24 FF

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM OD (FOR EXTERNAL USE)

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 45A

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

Operating instructions

Service Manual. Unit: Pellet burner. Type: ROT-POWER. Models: kw, kw

Operating manual. Pellet boiler. Orlan Pellet ISO 9001

USER GUIDE VOGUE MAX SYSTEM

PV1000agri pellet burner

Installation, operation and care. Pellet burner Replaces:

HDG K SERIES. Wood pellet boiler. The perfect alternative to fossil fuels. Receive up to

Unit: Pellet burner Type: ROT-POWER

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

New opportunities to heat with wood pellets

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

/2010 US/CA

INSTRUCTIONS FOR INSTALLATION, SETTING AND USE

Electronic Pellet Burner Controller NPBC-V3-1

Eco Angus Wood Pellet Boilers

Installation and maintenance Viking Bio 35 - pellet burner


Operation and maintenance manual for the. KSP Spark. series boilers equipped with feeders

OPERATING & MAINTENANCE MANUAL

Gasification boiler PYROLYT INSTRUCTION MANUAL. ver. 1.1

USERS GUIDE 24, 30. For installation guide see reverse of book

USER GUIDE LOGIC HEAT H

USER MANUAL AND TECHNICAL MANUAL

Operation Manual. An investment of a small amount of time to review this manual will ensure proper performance of your Coal-Trol Digital system.

SAFIRE 1600D, 1800D and 2100D Diesel / fuel oil heaters USAGE, INSTALLATION AND MAINTENANCE

Installation Manual PellX 20 & 35 kw Pellet Burner with External Auger

Installation, operation and maintenance. Pellet burner 18/01/2011. Replaces:

OPERATING INSTRUCTIONS. Drying cabinet DC 7774 DC Read the instructions before using the machine.

OPERATING INSTRUCTIONS with safety features

Thermo 230 / 231 / 300 / 301 / Troubleshooting

Wood pellets economical and environmentally friendly. Wood pellet heating

USERS GUIDE. LOGIC+ Combi 24, 30, 35

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Operating instructions

Transcription:

INSTALLATION, OPERATION AND MAINTENANCE ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-1/28

CONTENTS IMPORTANT INFORMATION 4 4 5 Notification to building authority Inspection Sweeping Warning! Make sure to cut the power supply to the boiler before removing the burner housing. Maintenance contract Replacing of spare parts ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-2/28

DIMENSIONS / ITEMS INCLUDED IN THE DELIVERY Bionet+ 12 89 7 9 406 Standard delivery Accessories 1340 8 3 4 1390 430 6 1 590 339 2 1191 351 336 436 10 397 5 581 250 Ø102 Kombinationsrökrör TECHNICAL DATA 50 Ø102 Performance Dimensions Design values Output using pellets Power of ignition resistor Normal power consumption Dimensions (width x depth x height) Weight Water contents Weight (burner) Design pressure Design temperature Recommended draught 5-12 kw 400 W 30 W 436 x 581 x 1340 mm 150 kg 50 l 23 kg 0,5-1,5 bar max 120 o C 5-20 Pa 101 Dimensions including comb.flue pipe is app. 1390 mm 1. Shunt outlet DN 25 male 2. Return line 3. Flame observation 4. Burner 5. Ash box 6. Sweeping hatch 7. Flue pipe Ø 102 mm 8. Cabel bushing 9. Comp. flue pipe 10. Ash compression Connections Expansion Drain Flue pipe connection Recommended chimney diameter and length DN 25 male DN 15 female Ø 102 mm Ø 100 mm, length min 5 m ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-3/28

OPERATING PRINCIPLE SAFETY AND ALARMS Automatic controls Versatile supplemental heat Chimney-sweeping NB! Always use caution when handling ashes, as some may still be glowing. Ash should be kept in a fire-proof container. 70 25 15 220 30 345 Expansion DN 20 A shunt connection for shunt valve ESBE TM20 is available as an accessory for connecting to an oblique chimney inlet. For details about the various alarm conditions please refer to Troubleshooting. ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-4/28

INSTALLATIONS EXAMPLE Installations exemple Bionet with solar tank 1. Boiler 2. Expansion card 3. Boiler sensor 4. Tank sensor 5. Bivalent shunt 6. Flow water sensor 7. Outdoor temp sensor 7b Indoor temperature sensor 8. Charging pump 9. Radiator pump 10. Safety relief valve 11. Air bleeder valve 12. Pressure gauge 13. Expansion vessel 14. Storage tank 10 13 11 Exp. vessel 12 2 3 1 BIONET 7b 7 To solar panel 11 ww cw 14 4 2 6 1 5 9 Rad.-system 8 Preheating cw ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-5/28

WIRING DIAGRAM ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-6/28

WIRING DIAGRAM BURNER OVERVIEW 1. Bottom plate 2. Controll card 3. Clutch wheel 4. Primary ring 5. Airbox 6. Fan 7. Optical monitor tube 8. Sluice gate 9. Auger motor 10. External auger motor 11. Chain 12. Auger tube 13. Burn pot 14. Top coupling 15. Level monitor, receiver 16. Burner skrew 7 9 14 15 11 3 8 5 6 4 2 10 1 12 13 16 ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-7/28

INSTALLATION WATER PIPING Chimney installation Flue connection and combustion air intake ATTENTION! The chimneysweep must be notied for inspection of the flue. CAUTION! The boiler has low flue gas temperatures, which, under certain conditions,might lead to condensation of flue gases. Mortar Flue pipe 30 30 mm incombustible insulation Radiator system and expansion vessel ATTENTION! See also separate instructions for filling of water. Open system: Closed system: System volyme Opening pressure Initial pressure Vessel volyme in litre litre* bar bar 70 C 90 C 500 1,5 0,5 35 80 1000 1,5 0,5 80 140 1500 1,5 0,5 80 140 2000 1,5 0,5 140 200 An open system with 500 litre water volume demands at least a 35 litre expansion vessel and a 1500 litre system volume a 80 litre expansion vessel. * System volume = boiler volume + storage tanks + piping volume + radiator volume. ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-8/28

WATER PIPING FILLING OF WATER Planning and installation Safety valve Electrical installation ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-9/28

MAINTENANCE, CARE, SWEEPING Boiler cleaning ATTENTION! Pay special attention to the pellets quality when you receive a new delivery or when you change supplier. ATTENTION! Show a great care when emptying the ash as it might be glowing hot. Ash must be kept in a fireproof container. The burner Once a year to once every second year PULL THE FLAME CONTROL SENSOR GENTLY OUT OF THE PIPE. CLEAN THE FLAME CONTROL SENSOR. For more information please refer to Advice about Fuel Pellets. THE BURNER CUP MUST BE CAREFULLY CLEANED TO ENSURE FLAWLESS OPERATION. ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-10/28

SETTINGS Adjusting combustion POWER MENU BURNER TYPE 12kW POWER HIGH AUGER 50% POWER HIGH FAN 36% POWER LOW AUGER 50% POWER LOW FAN 36% ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-11/28

START-UP IN OFF MODE NB! The initial firing of the burner following installation should always be conducted by an authorised installation engineer. (see Troubleshooting ) Off NB! The mains electric supply should always be disconnected when servicing the unit. NB! The time needed to run the cold-start firing procedure may vary due to differing amounts of fuel in the burner s auger, pellet quality, etc. Do not interfere with the ignition by letting light enter through the boiler s hatch. The burner s electric ignition program takes about 20 minutes. If ignition fails, the burner will automatically turn itself off, which is indicated by the red lamp. It is also possible to ignite the fuel manually using lighter fluid. Starting and stopping in operational mode ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-12/28

CONTROL PANEL LAYOUT CONTROL COMPUTER AND MENUS 1 2 3 6 5 4 Default Settings Service Levels 1 2 1. Display for set values 2. Display of operation and active alarms with indi cation light Green: Burner in operation Red: Alarm (burner not in operation) Flashing: Warning light (does not switch off the burner) Browsing forward in the menu Browsing backward in the menu Increases the set values Decreases the set values On (-Off) Service Reaching the menu level Service ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-13/28

DISPLAY MESSAGES AND POSSIBLE ADJUSTMENTS Description of level 1 menu -> Text on the display Description Setting possibilities Temperature boiler xx (80) C ON (OFF) Operation mode, pellet (The menu is displayed only when the electric resistors are activated) Boiler temperature, set value in brackets. Shows the actual temperature of the boiler, the set value shows the desired temperature. Operating mode. In ON mode the burner switches on when needed. In OFF mode the next menu displays Auger external manual. Options: pellet electric (Biomatic+ function) Adjustable between 20 and 95 C by means of the Plus and Minus buttons. Selectable by means of the Plus and Minus buttons. Selectable by means of the Plus and Minus buttons. Operation mode OFF, start, stop, temperature hold, max, medium, min, electric. This menu also displays the different For information only. starting stages. Temperature flue gas Flue gas temperature For information only. Operating time press plus key Operating time total Operating time high Operating time low Press the Plus button and then the arrow button forward to the next screen, if you want to view the operating time data. Total operating time of the burner. Operating time at high power. Operating time at medium power. The operating time is reset by pressing the Plus and Minus buttons simultaneously for 3 seconds. Text on the display Description Setting possibilities Pellets store Feeding factor Displays the amount of pellets in the store, a new figure can be entered in connection with reloading the pellets store. Displays the feeding power of the external auger For information and can be changed. Adjustable between 0 and 76.7 kg, see Determination of the feeding factor. Consumption average Displays the average consumption during the last 8 days. For information only. Consumption total Displays the total consumption of pellets. For information only. Auger external total Alarm pellets min Service press plus key Alarm ash removal Alarm cleaning Flue gas max C Displays the total operating time of the external auger in hours Sounds an alarm for calculated set minimum amount of pellets in the store. Press the Plus button and then the arrow button right to the next screen, if you want to view the service menu. Sounds an alarm for emptying the ash box upon reaching a set value. Sounds an alarm for cleaning of the combustion head upon reaching a set value. Audible alarm for cleaning of the convection parts upon reaching a set value For information only. Adjustable between 0 and 3.0 tons. Adjustable between 0 and 250 h, according to the operating time of the external auger. Adjustable between 0 and 250 h, according to the operating time of the external auger. Adjustable for alarm max value between 120 and 280 C Operating time min Minimum power level during operating time (only displayed when the min operating level is activated) Operating time electric el1 Operating time of the resistor 1 The number of electric resistors vary between models. (Biomatic+ function) Operating time electric el2 Operating time of the resistor 2 (Biomatic+ function) Pellets store press plus key Estimated time left Press the Plus button and then the arrow button forward to the next screen, if you want to view the pellets store data. Displays the number of operating days at the average consumption level in question. For information only. ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-14/28

DISPLAY MESSAGES AND POSSIBLE ADJUSTMENTS Description of menu 2 Service Service: To select this menu press both arrow buttons simultaneously for. approx. 5 seconds, then press the arrow button forward to the next screen. On (-Off) Poltinsäädöt Description of menu 3 Power Power: In order to activate this menu, select number 5 in the Service - Power menu by pressing the Plus button. Wait, until the number stops flashing and continue by pressing the arrow button to the right. El Step Text on the display Start backup heat 15 C Level monitor Optical monitor level Description Displays in brackets the activation of one of the electric resistors (enabled only in Biomatic+ models). Displays temperature difference from the target temperature, at which the electric resistor is switched on (enabled only in Biomatic+ models). Measured light intensity in percentage. The set limit value for the light in brackets in percentage. Measured light intensity in percentage. The set limit value for the light in brackets in percentage. Setting possibilities To activate one of the electric resistors enter number (3) here by means of the Plus button. Adjustable between 10 and 40 C. Adjustable between 10 and 90%. Adjustable between 1 and 98%. Text on the display Power 0 Burner type Description 12-50 kw Note: Don t change the factory setting, button -> resets the original settings. Power high auger Setting of fuel feed to high power (%). Power high fan Setting of speed of the fan to high power (%). Setting possibilities The menu is activated by entering code 5. Wait, until the number stops flashing and continue by pressing the arrow button to the right. 12, 15, 20, 30 and 50 kw 1 to 100%, adjusted by means of the Plus/Minus buttons.. 1 to 100%, adjusted by means of the Plus/Minus buttons. Testing press plus key Press the Plus button and then the arrow button to the right, if you want to view the test values. Power low auger Setting of fuel feed to medium power (%). 1 to 100% Auger external 0/1 manual test. Enabled by pressing the Plus button, disabled by pressing the Minus button. Fan 0 to 100% Enabled by pressing the Plus button. Auger burner 0/1 manual test. Enabled by pressing the Plus button. Ignition 0/1 manual test. Enabled by pressing the Plus button. Note: the test is performed only when the fan is running. Alarm 0/1 manual test of the alarm diode. Enabled by pressing the Plus button. El Step 0/1 manual test (enabled only in Biomatic+ models). Enabled by pressing the Plus button. Power regulation 0 See the next menu. English Selection of the display language. Finnish, Swedish, English, German or Italian can be selected by pressing the Plus/Minus buttons. Address 0 Not used. Power low fan Setting of speed of the fan to medium power (%). 1 to 100%, adjusted by means of the Plus/Minus buttons Power min auger Setting of fuel feed to low power (%). 1 to 100%, not in use at level 0. Power min fan Setting of speed of the fan to low power (%). Cleaning fan Frequency of cleaning blows 0 to 4 blows/h. Holding time Time between maintenance periods for the glow of embers Auger external time Setting of operating time for the external auger. 1 to 250 seconds. Auger external manual Hot starts Setting of operating time for the external auger in manual operation, see page 13. Displays the number of hot starts. 1 to 100%, adjusted by means of the Plus/Minus buttons. 20 to 120 minutes, in increments of five minutes, adjusted by means of the Plus/Minus buttons. 3 to 60 minutes, adjusted by means of the Plus / Minus buttons. Is reset by pressing the Plus/Minus buttons simultaneously for 3 seconds. Default set vxxxx Displays the version number of the processor and enables resetting the factory settings. The factory settings can reset by pressing the Plus button. Cold starts Displays the number of cold starts. Is reset by pressing the Plus/Minus buttons simultaneously for 3 seconds. ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-15/28

ACTIONS CHART ACTIONS CHART Bionet+ 12 / BeQuem 12 version 0906 OPERATING TIME TOTAL OPERATING TIME MAX OPERATING TIME MIN OPERATING TIME EL ESTIMATED TIME LEFT X d PELLETS STORE 0,0 t FEEDING FAKTOR 0,0 kg/h CONSUMPTION AVERAGE 0,0 kg/d CONSUMPTION TOTAL 0,0 t AUGER EXTERNAL TOTAL XX h ALARM PELLETS MIN 0,0 t FUEL EL Electric heating is available when nr 3 is selected in EL STEP menu. ALARM ASH REMOVE X ( x) ALARM CLEANING 0( Xh) FLUE GAS XXX C MAX 240 C FUEL PELLETS + EL Only Biomatic+ function MAIN MENU TEMPERATURE BOILER 55(80) C ON (-OFF) AUGER EXTERNAL MANUAL OFF FUEL PELLETS OPERATINGMODE MAX TEMPERATURE FLUE GAS xx C OPERATING TIME press plus key PELLETS STORE press plus key SERVICE press plus key Menu is only seen when OFF-set chosen. Fun must be in operation before function of the ignition element can be found. AUGER EXTERNAL 0 FAN 0 AUGER BURNER 0 IGNITION 0 ALARM 0 EL STEP 0 SERVICE MENU SERVICE EL STEP 0 (0) LEVEL MONITOR XX (50%) OPTICAL MONITOR XX ( 50%) TEST OUTPUTS Press plus key POWER 0 ENGLISH ADDRESS DEFAULT SETTINGS vxxxx DIFF TANK NO Change nr. 0 to nr. 3 when El STEP using. Power menu is available when nr. 0 is changed to nr. 5. Service meny shows when pushing same time buttoms < and > for 5 sec. Move forward when nr. on display stops winking. POWER MENU BURNER TYPE 12kW POWER HIGH AUGER 50% POWER HIGH FAN 36% POWER LOW AUGER 50% POWER LOW FAN 36% POWER MIN AUGER 0% POWER MIN FAN 0% CLEANING FAN 2/h HOLDING TIME 60min AUGER EXTERNAL TIME 30s AUGER EXTERNAL TIME MAN. 15min HOT STARTS BURNER X COLD STARTS BURNER X SEQUENCE Press right arrow to leave menu. Not used! ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-16/28

TROUBLESHOOTING Problem Check Remedy All display segments are out. that the fuses of the control unit of the burner are intact and the main switch has been turned ON. has the over-temperature protection tripped? Replace the defective fuse in the control unit or turn ON the power by means of the main switch. Note! Disconnect the device from electricity supply before replacing the fuse. The size of fuses F1 and F2 is 4A/230 V. If the cause of over-heating cannot be determined with certainty, contact an authorised technician. If the over-temperature protection of the boiler has tripped, put it back into operation by pressing the RESET button. After this switch the control unit OFF and then back ON. Also check that the 3-phase current is correctly connected. Problem Check Remedy The red operation indication is on and the display reads: ALARM MAX THERMOSTAT, or ALARM MAX THERMOSTAT ELECTRIC The over-temperature protection of the boiler has tripped. that the motor shaft rotates the auger and the motor of the external auger operates. (In most cases the default setting of the operating time of the external auger (30 seconds) is not long enough to bring sufficient amount of pellets to the burner. If the problem cannot be removed by means of the above checks and remedies, the operating time of the external auger may be too short. In such cases increase the operating time (see page 15, menu 3 -> Auger external time ). However, the operating time must not be so long that pellets accumulate into the drop tube.) has the over-temperature protection tripped? check the circulation pump. If the motor does not rotate, disconnect the power cable from the boiler and connect it directly to a mains socket by means of the additional cable provided. If the motor has been over-heated due to a blockage or for some other reason, the over-temperature protection of the motor may have been tripped. The motor will not start until it has been cooled down. Also check that there are no blockages in the auger. If there are problems with the motor, contact an authorised technician. If the cause of over-heating cannot be determined with certainty, contact an authorised technician. If the over-temperature protection of the boiler has tripped, put it back into operation by pressing the RESET button. After this switch the control unit OFF and then back ON. Also check that the 3-phase current is correctly connected. The red operation indication is on. The display reads: ALARM PELLETS NO. The burner is requesting fuel, but has not received it. that there are pellets in the fuel storage. that the inclination of the drop pipe is not too gentle. that the inclination of the external auger is not too steep (max 45 ) or feeding of fuel has not stopped, because pellets have been stuck in the silo. Add pellets. Shake the drop tube and change the inclination so that pellets will not get stuck. Adjust the auger into a more gentle angle and turn it back and forth a few times so that the pellets come loose. The feed opening of fuel must be located in the middle of the fuel store (applies to small week stores). The red operation indication is on and the display reads: CONTROL EL. IGNITION or CONTROL OPTICAL MONITOR The cause of the problem is that the optical flame monitoring of the burner has not detected flame during a certain period of time. No fuel has entered into the combustion head. that the flame guard and/or the combustion head is not full of ash and the flame guard has not over-heated or sooty. Remove ash, clean the combustion head from loose ash and wipe the flame guard clean. If the flame guard becomes easily sooty, the cause may be incorrect settings or too low underpressure in the furnace. In such cases call a technician. ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-17/28

TROUBLESHOOTING Problem Check Remedy Problem Check Remedy The device has been stopped during a hot start. The device has been stopped during a cold start. Check that the pellets fed into the combustion head are whole. The fuel consists of pieces, the burner cannot keep up the embers. The reason for recurring stops may also be an excessive play in the blocking feeder, which makes it difficult to keep up the embers. Check the function of the ignition resistor, unless ignition does not succeed after two start attempts. If the cause of the operation cannot be determined with certainty or the ignition resistor must be replaced, contact an authorised technician. that the feed auger, blocking feeder and burner auger rotate and are not blocked, e.g. because of a foreign object. A possible foreign object in the pellet fuel must be removed, if it gets stuck in the blocking feeder or in one of the feed augers. Remove the upper connection and take out the possible foreign object from the feed auger or blocking feeder. In connection with the inspection of the burner auger remove the four augers located between the inner and middle part and pull out the burner auger from the tube. Be sure to disconnect all cable connections. The red operation indication is on and the display reads: ALARM LEVEL MONITOR, or ALARM BLOCKAGE The cause of the problem is that the optical flame monitor of the burner has not detected light during a certain period of time. No fuel has entered into the combustion head. is there fuel in the upper connection? If there is no fuel in the upper connection of the burner, check the cable connections of the level switches. If this does not help, wipe the level switches clean. If the external feed of the burner does not start in spite of this or the level switches must be cleaned continuously, they may be defective and, when necessary, should be replaced by an authorised technician. ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-18/28

ADVICE ABOUT FUEL PELLETS STORAGE PLANNING / GUARANTEE ATTENTION! If sintered ash is formed, the burn pot must be continuously cleaned of sintered material (with a table spoon for example). ATTENTION! Damp pellets must be rejected immediately. FUEL RECOMMENDATION Raw material Chemically untreated barkless wood Diameter 8 mm Length 15 to 32 mm Volume weight over 600 kg/m 3 Moisture content less than 10 % Ash content less than 0.7 weight % Fine material content max 4 weight % Melting temperature of ash > 1100 C Energy content >4,75 kwh/kg Guarantee Disposal ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-19/28

FEEDING SYSTEM WEEKLY STORAGE FEEDING SYSTEM DEPO / FEEDO PF300 weekly storage NOTE! Installation of PS300 / Feedo, see separate manuals for each product. Depo Feedo NOTE! Installation of Depo / Feedo, see separate manuals for each product. ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-20/28

920 mm 758 mm 602 mm 606 mm 602 mm 699 mm 606 mm 602 mm FEEDING SYSTEM WEEKLY STORAGE ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-21/28 1208 mm 1500 mm

1500 mm FEEDING SYSTEM DEPO / FEEDO 606 mm ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-22/28

920 mm 758 mm FEEDING SYSTEM DEPO / FEEDO 606 mm ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-23/28

DECLARATION OF CONFORMITY NOTES ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-24/28

NOTES ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-25/28

NOTES ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-26/28

INSTALLATION PROTOCOL ATTENTION! In this function, the burner won t stop when the boiler water reaches desired temperature: boiling risk! Flue gas temp. High CO O 2 CO 2 Air-fuel ratio Efficiency Draught i mm Fan Effect % Flue gas temp. Low CO O 2 CO 2 Air-fuel ratio Efficiency Draught i mm Fan Effect % Flue gas temp. Min CO O 2 CO 2 Air-fuel ratio Efficiency Draught i mm Fan Effect % Retailer / Installer Installed by Inst. date ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-27/28

ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18-28/28