Gas cooler series RC 1.1

Similar documents
Gas cooler series RC 1.1

Gas cooler series TC-Standard+

Gas cooler series TC-Standard+ X2

Portable sample gas conditioning PCS.smart+

Portable sample gas conditioning PCS.smart

Peristaltic condensate pumps CPsingle, CPdouble X2 (Versions with ATEX 2, IECEx and Cl.1 Div.2 approval)

Sample Gas Probes Series GAS 222

Portable sample gas conditioning. PCS.smart (+) Installation and Operation Instructions. Original instructions. Analysentechnik BE /2017

System Components and Accessories for Sample Gas Conditioning. Data Sheet 10/ EN June 2004

VC-1, VC-1-SL, VC-2-L, VC-2-SL

Portable sample gas conditioning. PCS.smart (+) Installation and Operation Instructions. Original instructions. Analysentechnik BE /2018

HYGROPHIL H process hygrometer

Compact Gas Conditioning MAK10

2 OZONFILT And Bono Zon Ozone Plants

Company profile. ANKERSMID is a privileged partner of several companies like Siemens, BASF, Bayer, Umicore, Dräger and many more.

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

EC Ultra Low Gas Cooler EC-30C Instruction Manual Version Software Version 1.00

Safety vacuum drying oven for flammable solvents

NEOTeCHA Reactor Sampling Type PV

gas monitoring system

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Vacuum drying oven for non-flammable solvents

Heated Gas Sampling Probe PSG Basic

Technical data sheet. Lyovapor L-300

Emission Monitoring System

Micro/Ultra Filtration System StamoClean CAT 430

Filters & Centrifugal Separators

Ultra Low Gas Cooler Series EC EC30 and EC-30/FD

VD 53 - Vacuum drying oven for non-flammable solvents

Chemical Pumps Vertical Chemical Pump Type TNP

Shop. Item Information. Interface I-100 For V-100/V-7x0. Send item information. Show item in shop. Add item to cart.

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

Infrared Detectors. Special-Sensors for. Automation

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar abs) Press. (bar g) (kg)

Beck. The differential pressure transmitter for air

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

2 OZONFILT And Bono Zon Ozone Plants

portable gas analyser

VACUUM HEATING AND DRYING OVENS Gentle and safe

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Evaporators. In this section. Rotary Evaporators Crystalisation Distillation Drying Reflux Solution Concentration Volatiles Glassware

SIHI Dry GD S Sizes S450, S650

Hei-VAP Precision. for the highest level of accuracy. Vacuum Pumps. RPM Regulated Vacuum Pumps

Users Manual Pury 250e Gas Purification System

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

A-DRY Heatless adsorption compressed air dryers

Rotary Evaporators, Heidolph

KMF Environmental test chamber for constant climate

ThermoDual Domestic hot water charging system

Old documentation - Only for your information! Product is not available anymore!

Concept WVM Brief description. Efficient compressed-air adsorption dryer with vacuum regeneration. NEW! Now with improved ZDMC2

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

6-2.1 ANKERSMID Diaphragm pump Application No contamination of the media AMP 510/518/530 due to oil-free operation Low maintenance

Brawa-Mix Thermostatic mixing valves

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

transport handle gas ballast valve robust design for long life easy to clean integrated oil level window quiet running, minimized vibrations

Lyovapor L-300 Technical data sheet

Extreme industrial environments Air/water heat exchangers (roof-mounted, wall-mounted) Recooling system

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing

Dräger Polytron 8310 IR Detection of flammable gases and vapour

FIPA Vacuum Components

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Rotary Evaporators designed

Compressed air preparation Compressed air storage Moisture management. Catalog #1

TDS Conductivity Probe In-Line conductivity measurement

Short Path Distillation Unit. KDL 1 BASIC Version 2015

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

Specialist Suppliers of Gas Analysis Equipment BÜHLER PROBE CATALOGUE. What You Measure, We Manage

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

Sample gas filter AGF-PV-30, AGF-PV-S2, AGF-T-30, K-AGF-PV-30, RAF-PV-30, ADF-PV-30. Installation and Operation Instructions. Original instructions

Measurement Solutions for Refrigeration Technology.

portable gas analyser

Compressed air treatment. Condensate drains OMEGA AIR

Rotary Evaporators. RE100-Pro. LCD Digital Rotary Evaporator. Features:

Duct Temperature Sensors

Sintrol Snifter A1+ Manual. Version 1.2.2

Technical information for installation and operation

Dust Concentration Meter

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

The Safest Connections...

Control unit PPT/RS,, Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and contr

OPTISENS TUR 2000 Technical Datasheet

VERSO Air Handling Units

COMPACT FLAME CONTROLLER CFC 1000

Refrigeration Dryers TG TI Series

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Conductive Leakage detectors of the Leckstar range

condensate pumps For air conditioning and refrigeration technology eckerle.com

Introduction to Flow Switch

FluidAqua Mobil FAM 5

BINDER Scientific Product Catalog

Compact Catalog Solar

RS /E-EV C01 SERIES

Certificate: / 9 September 2014

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

KK70 Silent. Installation and Operating Instructions L V001

Transcription:

Gas Analysis Gas cooler series In the chemical industry, petrochemistry or biochemistry, reliable process control relies on prompt and exact determination of the operating parameters. Here, gas analysis is the key for safe and efficient control of process flows, environmental protection and quality assurance. This benefits controlling flue gas emission in power stations or exhaust gas analysis in automotive engineering, as well as the efficient control of air separators or sterile production and packaging in the food industry. Many of the analysis processes used in these fields require extracting the sample gas. This inevitably also extracts process-related contamination such as particles or moisture. These in turn can impact the measurement results or damage the measuring cells. The sample gas must therefore be conditioned before entering the analyser. The is a compressor sample gas cooler for up to 2 gas paths and is an essential component for sophisticated analysis systems. Compact design: Pre-installed and ready to connect One or two gas paths Heat exchanger made from stainless steel, Duran glass and PVDF Bühler constant control system Self-monitoring Cooling block temperature display Status alarm Rated cooling power 360 kj/h Dew point stability 0.1 C CFC-free Moisture detector, analogue output, filter and condensate pump optional Successor to the EGK 1/2 and EGK 1SD DE450028 11/2018 page 1 / 6 Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen Tel. +49 (0) 21 02 / 49 89-0, Fax: +49 (0) 21 02 / 49 89-20 E-Mail: analyse@buehler-technologies.com Internet: www.buehler-technologies.com

Gas cooler technical data Gas Cooler Technical Data Ready for operation Rated cooling capacity (at 25 C) after max. 15 minutes 360 kj/h Ambient temperature 5 C to 50 C Gas outlet dew temperature, preset approx. 5 C Dew point fluctuations static: in the entire specification range: ± 0.1 K ± 1.5 K IP rating IP 20 Housing Packaging dimensions Weight incl. heat exchanger Stainless steel approx. 420 x 440 x 350 mm approx. 15 kg Electric supply 115 V, 60 Hz or 230 V, 50/60 Hz ± 5% Plug per DIN EN 175301-803 Electrical data 230 V 115 V Alarm output switching connection Installation Technical Data - Options Technical Data Peristaltic Pumps CPsingle / CPdouble Flow rate Vacuum inlet Pressure inlet Outlet pressure Hose Condensate outlet Typical power input: 296 VA 302 VA max. operating current: 2 A 3.5 A max. 250 V, 2 A, 50 VA Connector per DIN EN 175301-803 stand-alone or wall-mounted 0.3 L/h (50 Hz) / 0.36 L/h (60 Hz) with standard hose max. 0.8 bar max. 1 bar 1 bar Protection class IP 40 Materials Hose: Connections: 4 x 1.6 mm Analogue Output Cooler Temperature Technical Data Signal Hose nipple Ø6 mm Screw connection 4/6 (metric), 1/6-1/4 (US) Norprene (Standard), Marprene, Fluran PVDF 4-20 ma or 2-10 V corresponds to -20 C to +60 C cooler temperature Connection M12x1 plug, DIN EN 61076-2-101 Technical Data Filter AGF-PV-30-F2-L Ambient temperature 3 C to 100 C max. operating pressure with filter 2 bar Filter surface 125 cm 2 Filter mesh 2 µm Dead volume Materials Filter: Seal: Filter element: 108 ml PVDF, Duran glass (parts in contact with media) Viton sintered PTFE 2 Bühler Technologies GmbH We reserve the right to amend specification. DE450028 11/2018

Technical Data FF-3-N Moisture Detector Ambient temperature 3 C to 50 C max. operating pressure with FF-3-N 2 bar Material PVDF, PTFE, epoxy resin, stainless steel 1.4571, 1.4576 Performance data Cooling capacity (kj/h) Ambient temperature ( C) Note: The limit curves for the heat exchangers exchanger apply to a dew point of 65 C. Diagram typical installation Sample gas/calibrating gas Cooler Sample gas 1 Sample gas probe 2 Sample gas line 3 Reversing tap 4 Sample gas cooler 5 Automatic condensate drain or peristaltic pump 6 Fine mesh filter 7 Moisture detector 8 Sample gas pump 9 Flow meter 10 Analyser See data sheets for individual component types and data. Heat exchanger description The energy content of the sample gas and the required cooling capacity of the gas cooler is determined by three parameters: gas temperature ϑ G, (inlet) dew point τ e (moisture content) and volume flow v. The outlet dew point rises with increasing energy content of the gas. The approved energy load from the gas is therefore determined by the tolerated rise in the dew point. The following limits are specified for a normal standard operating point of τ e = 65 C and ϑ G = 90 C. The maximum volume flow v max in Nl/h of cooled air is indicated, so after moisture has condensed. If the values fall below τ e and ϑ G, the flow v max may be increased. For example, on the TG heat exchanger the parameter triple τ e = 65 C, ϑ G = 90 C and v = 280 Nl/h may also be used in place of τ e = 50 C, ϑ G = 80 C and v = 380 Nl/h Please contact our experts for clarification or refer to our design program. DE450028 11/2018 We reserve the right to amend specification. Bühler Technologies GmbH 3

Heat exchanger overview Heat exchanger Version / Material TS TS-I 2) Stainless steel TG TG TV-SS DTS (DTS-6 3) ) TV-SS-I 2) DTS-I (DTS-6-I 3) ) 2) DTG DTG DTV 3) 2) 3) DTV-I Glass PVDF Stainless steel Glass PVDF Flow rate v max 1) 530 L/h 280 L/h 155 L/h 2 x 250 L/h 2 x 140 L/h 2 x 115 L/h Inlet dew point τ e,max 1) 80 C 80 C 65 C 80 C 65 C 65 C Gas inlet temperature ϑ G,max 1) 180 C 140 C 140 C 180 C 140 C 140 C Max. Cooling capacity Q max 450 kj/h 230 kj/h 120 kj/h 450 kj/h 230 kj/h 185 kj/h Gas pressure p max 160 bar 3 bar 3 bar 25 bar 3 bar 2 bar Pressure drop Δp (v=150 L/h) 8 mbar 8 mbar 8 mbar 5 mbar each 5 mbar each 15 mbar each Dead volume V tot 69 ml 48 ml 129 ml 28 / 25 ml 28 / 25 ml 21 / 21 ml Gas connections (metric) G1/4 GL 14 (6 mm) 4) DN 4/6 6 mm tube GL14 (6 mm) 4) DN 4/6 Gas connections (US) NPT 1/4" GL 14 (1/4") 4) 1/4"-1/6" 1/4" tube GL14 (1/4") 4) 1/4"-1/6" Condensate out connections (metric) Condensate out connections (US) 1) Max. cooling capacity of the cooler must be considered 2) Models marked I have NPT threads or US tubes, respectively. 3) Condensate drain only possible with condensate pump 4) Gasket inside diameter G3/8 GL 25 (12 mm) 4) G3/8 Tube 10 mm (6 mm) GL18 (10 mm) 4) DN 5/8 NPT 3/8" GL 25 (1/2") 4) NPT 3/8" Tube 3/8" (1/4") GL18 (3/8") 4) 3/16"-5/16" Dimensions 102.75 Filter (optional) 160 Filter (optional) 202.5 40 310 Ø7x10 15-65 341 87 329 94.5 233 21 S1 S2 S3 S1 = electric supply S2 = alarm contact S3 = analogue output 4 Bühler Technologies GmbH We reserve the right to amend specification. DE450028 11/2018

Ordering instructions Gas cooler The item number is a code for the configuration of your unit. Please use the following model key: 4596 2 1 1 0 X X X X X 0 X X X 0 0 0 0 0 Product Characteristics Voltage 1 115 V, 60 Hz 2 230 V, 50/60 Hz Heat exchanger 1 1 0 1 gas path, stainless steel/ (TS), metric 1 1 5 1 gas path, stainless steel/ (TS-I), US 1 2 0 1 gas path, glass/ (TG), metric 1 2 5 1 gas path, glass/ (TG), US hoses 1 3 0 1 gas path, PVDF/ (TV), metric 1 3 5 1 gas path, PVDF/ (TV-I), US 2 6 0 2 gas paths, stainless steel/ (DTS), metric 2 6 1 2 gas paths, stainless steel/ (DTS-6) 1), metric 2 6 5 2 gas paths, stainless steel/ (DTS-I), US 2 6 6 2 gas paths, stainless steel/ (DTS-6-I) 1), US 2 7 0 2 gas paths, glass/ (DTG), metric 2 7 5 2 gas paths, glass/ (DTG-I), US hoses 2 8 0 2 gas paths, PVDF/ (DTV) 1), metric 2 8 5 2 gas paths, PVDF/ (DTV-I) 1), US Condensate drain 2) 0 0 without condensate drain 1 0 CPsingle with adapter, angled 3) 2 0 CPdouble with adapter, angled 3) 3 0 CPsingle with screw connection, metric/us 3) 4 0 CPdouble with screw connection, metric/us 3) Filter/moisture detector 0 0 without filter, without moisture detector 0 1 without filter, 1 moisture detector 0 2 without filter, 2 moisture detectors 1 0 1 filter, without moisture detector 1 1 1 filter, 1 moisture detector 1 2 1 filter, 2 moisture detectors 2 0 2 filters, without moisture detector 2 1 2 filters, 1 moisture detector 2 2 2 filters, 2 moisture detectors Status outputs 0 0 status output only 1 0 Analog output option, add-on 1) Condensate outlets only suitable for connecting peristaltic pumps. 2) Peristaltic pumps also available for separate installation, see data sheet 450020. 3) Each gas path equipped with a peristaltic pump. The supply voltage corresponds with that of the main unit. DE450028 11/2018 We reserve the right to amend specification. Bühler Technologies GmbH 5

Consumables and accessories Item no. Description 44 10 00 1 Automatic condensate drain 11 LD V 38 44 10 00 4 Automatic condensate drain AK 20, PVDF 44 10 00 5 Condensate trap GL 1; glass, 0.4 L 441 00 19 Condensate trap GL 2; glass, 1 L 4492 0035 012 Norprene replacement hose with angled connections for CP peristaltic pump 0.3 L/h 4492 0035 016 Norprene replacement hose with one angled connection and one screw connection (metric) for CP peristaltic pump 0.3 L/h 4492 0035 017 Norprene replacement hose with one angled connection and one screw connection (US) for CP peristaltic pump 0.3 L/h 6 Bühler Technologies GmbH We reserve the right to amend specification. DE450028 11/2018