Client: IZEN Co., Ltd. 242, Aegibong-ro, Wolgot-myeon Gimpo-si, Gyeonggi-do 415-873 REPUBLIC OF KOREA Contact Person: ISA AC Kim Tel.: +82-31-999-7300, 070-4705-1878 Fax.: +82-31-997-3147 Manufacturing place: Same as client Test subject: Product: Shower Toilet Seat (Electric Bidet) Type: for IZEN IB-7500R, IB-7500, IB-7300, IB-7200, IB-7100, IB-7000, ATS-1000L, ATS-1000R, ATS-909L, ATS-909R, ATS-908L, ATS-908R, ATS-907L, ATS-907R, BB-1000, BB-900, BB-800, HDBR-600, HDB-650, HDB-630, AQUALET 1000, AQUALET 900, AQUALET 800, EB-1000, EB-900, EB-800 Type: for INSTA 5095KST, 5096KST, 5097KST Test specification: EN 1717:2000 Purpose of examination: Test result: Test according to the test specification Evaluation and categorization positive: The test results show that the presented product is in compliance with the specified requirements The test results show that the presented product is compliance with the specified requirements and symbol AB for protection unit on the marking plate is complied with the requirements. This technical report may only be quoted in full. Any use for advertising purposes must be granted in writing. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. Page 1 of 6
1 Description of the test subject 1.1 Function Shower Toilet Seat (Electric Bidet) The shower toilet seat is dedicated to the cleaning of the genital area as well as with the lady shower for the vaginal area. Manufacturer s specification for intended use: (According to the user manual) Manufacturer s specification for predictive misuse: (According to the user manual) 1.2 Consideration of the foreseeable misuse Not applicable Covered through the applied standard Covered by the following comment Covered by attached risk analysis 1.3 Technical Data 220-240 V~; 50/60 Hz; 600-700 W; IPX4; Class I 2. Order 2.1 Date of Purchase Order, Customer s Reference 2015-06-23 2.2 Receipt of Test Sample, Location Page 2 of 6
Testing Laboratory 2.3 Date of Testing 2015-06-25 to 2015-07-15 2.4 Location of Testing TÜV SÜD Korea Testing Laboratory #315 and 316, MARIO Tower, 222-12, Guro-Dong, Guro-Gu, 152-050, Seoul, REPUBLIC OF KOREA 2.5 Points of Non-compliance or Exceptions of the Test Procedure N/A 3. Test Results 3.1 Positive Test Results 1) Clause 5.2 Determination of fluid categories which are or could be in contact with potable water According to Annex B of EN 1717:2000, this product is intended use for shower and cleaning for human, especially genital, anus area as well as with the lady shower for the vaginal area in the toilet. So it can be categorised to CAT 5 based on table B.1. 2) Clause 5.8 Matrix of the protection units appropriate to fluid categories Water flow of liquid chamber in the appliance is shown as the following diagram. Protection units consist of air gap, water level sensor and overflowing drain on liquid chamber. It can belong to type AB of Annex A of EN 1717:2000. Page 3 of 6
Page 4 of 6
Page 5 of 6
3.2 Points of non-compliance according to the test specification N/A 4. Remark The user manual has been examined according to the minimum requirements described in the product standard. The manufacturer is responsible for the accuracy of further particulars as well as of the composition and layout. 4.1 Remarks to Factory N/A 5. Summary Positive The test specifications are met. Engineer:... Tommy Lee Technical Report checked:... Brian Cha Page 6 of 6