563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1

Similar documents
563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5

563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES

597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8

697C (60 HZ) Sizes 018 thru 060

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4

661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS

PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES

Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3

Product Data PA13NA PA13PA FEATURES AND BENEFITS

Product Data. 38EYA (60Hz) 12 SEER Split-System Cube Heat Pump with Puron Refrigerant FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS.

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS

R4H4. Product Specifications

R4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 018 thru 060

Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

WCH5**4. Product Specifications

650A (60 Hz) QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 650A.24.1

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

N4H4. Product Specifications

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

A 14 SEER Heat Pump with R---410A Refrigerant Series

N4A6. Product Specifications

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. Efficiency. S S Reliability

R 410A Ducted Horizontal Air Conditioner

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data. Efficiency

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA

Product Data. Efficiency

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Product Data. Efficiency

HEATING & COOLING 38YCA Sizes 018 thru YCN Sizes 024 thru 048. Copyright 1994 Carrier Corporation

Advance Product Data

Commercial High-Efficiency Condensing Units

Installation Instructions

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

2 shp 13 lc 1 36 t - 1 a

Product Data. Efficiency

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. Model 113A Legacy-RNC Series Air Conditioner with Puronr INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Commercial High-Efficiency Condensing Units

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

PAJ3. Product Specifications

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Product Data. Efficiency

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

INDUSTRY LEADING FEATURES 2 5 / BENEFITS

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

MAC N-407 Air-Cooled Chiller

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

Advance Product Data

Advance Product Data

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

Transcription:

12 SEER ELECTRIC AIR CONDITIONER 563G (60 Hz) Sizes 018 thru 060 Model 563G Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable cooling performance. Built into these units are the features most desired by homeowners today including SEER ratings of at least 12.0 when combined with specific Bryant equipment. All models are listed with UL (U.S. and Canada), ARI, and CEC. The 563G meets the Energy Star guidelines for energy efficiency. AVAILABLE OPTIONS UNIT DESIGN Copper tube, enhanced sine wave aluminum fin coil is designed for optimum heat transfer. Vertical air discharge carries sound and hot condenser air up and away from adjacent patio areas and foliage. Heat pump style base pan for easy removal of water, dirt, and leaves. ELECTRICAL RANGE All units are offered in single phase 208/230v. WIDE RANGE OF SIZES Available in 7 nominal sizes from 018 through 060 to meet the needs of residential and light commercial applications. COMPRESSOR This unit features a scroll compressor, which is significantly more efficient than conventional compressors. Its simple design offers improved reliability and each compressor is mounted on rubber isolators for additional sound reduction. Scroll compressors start under most system loads, minimizing the need for start assistance components. For improved serviceability, units are equipped with a compressor terminal plug. Continuous operation is approved down to 55 F (12.8 C) in the cooling mode. (See cooling performance tables.) Operation down to 0 F or 20 F is approved when low-ambient requirements are met. WEATHER-PROTECTIVE CABINET The access panels and top are protected with a galvanized coating, then treated with a layer of zinc phosphate to which a modified polyester powder coating is applied and baked on. This provides each unit with a hard, smooth finish that will last for many years. All screws on cabinet exterior are coated for a long-lasting, rustresistant, quality appearance. TOTALLY ENCLOSED FAN MOTOR Means greater reliability under adverse weather conditions and dependable performance for many years. The permanent-split-capacitor type motor was designed for optimum efficiency. The motor was tested and qualified under extreme conditions to ensure greatest reliability. APPLICATION VERSATILITY The 563G can be combined with a wide variety of evaporator coils and blower packages to provide quiet, dependable comfort. can be installed on a roof or at ground level on a slab. EXTERNAL SERVICE VALVES Both service valves are brass, front seating type with sweat connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures. EASY SERVICEABILITY One access panel provides access to electrical controls and compressor. Removal of wire dome gives access to fan motor and removal of the top gives access to the coil. COMPRESSOR PROTECTION Includes a suction tube accumulator on 048 and 060 sizes that reduces the amount of liquid refrigerant reaching the compressor. All compressors are protected by internal temperature and current sensitive overloads. An internal pressure relief is provided for high-pressure protection to the refrigerant system. LIMITED WARRANTY Standard 5-year limited warranty on all parts and compressor. Form No. PDS 563G.18.1

DIMENSIONS A03015 DIMENSIONS (IN.) UNIT SIZE SERIES A B C D E F G H J K L M N P MINIMUM MOUNTING PAD DIMENSIONS 563G018 A 22-1/2 29-15/16 3-3/16 5/8 3-11/16 18-1/8 19-3/4 22-1/4 14-3/8 19-9/16 22-1/16 10-1/4 9-1/2 11-1/2 22-1/2 x 22-1/2 563G024 A 22-1/2 32-15/16 3-3/16 5/8 3-11/16 18-1/8 19-3/4 22-1/4 14-3/8 19-9/16 22-1/16 14-3/4 14 10 22-1/2 x 22-1/2 563G030 A 30 27-15/16 3-3/16 3/4 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 14-3/4 14 11 30 x 30 563G036 A, B 30 27-15/16 3-3/16 3/4 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 14-3/4 14 11 30 x 30 563G042 A, B 30 33-15/16 3-1/4 7/8 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 14-3/4 14 13 30 x 30 563G048 A 30 33-15/16 3-1/4 7/8 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 15-1/2 14-3/4 13 30 x 30 563G048 B 30 39-15/16 3-1/4 7/8 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 15-1/2 14-3/4 15 30 x 30 563G060 A 30 39-15/16 3-1/4 7/8 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 15-1/2 14-3/4 15 30 x 30 563G060 B 30 39-15/16 3-1/4 7/8 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 15-1/2 14-3/4 15 30 x 30 2

RECOMMENDED TUBE DIAMETERS LIQUID TUBE DIAMETER (IN.) VAPOR TUBE DIAMETER (IN.) UNIT SIZE 0 to 50 Ft Tube Length Long-Line Applications* 0 to 50 Ft Tube Length Long-Line Applications* (Maximum Diameter) 018, 024 5/8 3/4 030, 036 3/4 7/8 3/8 3/8 042, 048 7/8 1-1/8 060 1-1/8 1-1/8 * For tube sets between 50 and 175 ft. or 20 ft. vertical differentiation, consult Residential s Split Long-Line Application Guideline. CHECK-FLO-RATER PISTON CHART PISTON* UNIT SIZE-SERIES IDENTIFICATION NO. 018-A 52 024-A 61 030-A 70 036-A, B 73 042- A, B 82 048-A 90 048-B 88 060-A, B 104 * Piston listed is for any approved coil non-capillary tube combination. Piston is shipped with outdoor unit and must be installed in an approved indoor coil. CHARGING SUBCOOLING (TXV-TYPE EXANSION DEVICE) UNIT SIZE-SERIES REQUIRED SUBCOOLING ( F). 018-A 9 024-A 13 030-A 11 036-A, B 14 042-A, B 12 048-A, B 11 060-A, B 11 UNITARY AIR CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. * As an ENERGY STAR Partner, Bryant Heating & s has determined that this product meets the ENERGY STAR guidelines for energy efficiency. REGISTERED QUALITY SYSTEM Refer to the combination ratings in the Product Data Sheet for system combinations meeting ENERGY STAR efficiency standards. * 3

See notes on page 5. SPECIFICATIONS UNIT SIZE-SERIES 018-A 024-A 030-A 036-A/B 042-A/B Operating Weight (Lb) 133 138 161 169 180 ELECTRICAL Volts Hertz Phase 208/230 60 1 Operating Voltage Range* 187 253 Compressor Rated Load Amps 9.0 10.9 15.0 16/16.7 20.0/18.6 Locked Rotor Amps 41.0 54.0.5 88.0/97.0 104.0/115.0 Condenser Fan Motor Full Load Amps 0.5 0.75 0.8 1.1 1.1 Min Ampacity for Wire Sizing 11.8 14.4 19.6 21.1/22.0 26.1/24.5 Min Wire Size (60 C Copper) AWG 14 14 14 12 10 Min Wire Size (75 C Copper) AWG 14 14 14 12 10 Max Wire Length (Ft) (60 C Copper) 66 53 39 55/ 74/80 Max Wire Length (Ft) (75 C Copper) 50 37 52/54 70/76 Max Branch Circuit Fuse Size** 20 25 30 30 40 COMPRESSOR AND REFRIGERANT Compressor Type Scroll Manufacturer Copeland Copeland/Millennium Copeland/Millennium Temperature and Current Protection Internal Line Break Refrigerant Type R-22 Amount (Lb) 5.0 5.25 6.25 6.50 6.75 CONDENSER COIL AND FAN Coil Face Area (Sq Ft) 10.8 11.6 14.9 14.9 18.7 Fins per In. Rows Circuits 25 1 2 25 1 2 25 1 2 25 1 2 25 1 3 Fan Motor (PSC) HP and RPM 1/12 and 1100 1/10 and 1100 1/8 and 825 1/5 and 825 1/5 and 825 Volts Hertz Phase 208/230 60 1 Condenser Airflow (CFM) 1700 2000 2500 2800 2800 OPTIONAL EQUIPMENT Coastal Filter KAACF1001MED KAACF1101LRG Time-Delay Relay KAATD0101TDR Cycle Protector KSACY0101AAA Crankcase Heater KAACH1201AAA Start Assist Capacitor/Relay Type KSAHS1501AAA Start Assist PTC Type KAACS0201PTC Sound Hood KSASH1801COP KSASH0601COP TXV (RPB) KAATX0201RPB KAATX0301RPB KAATX0401RPB KAATX0501RPB TXV (Hard Shutoff) KSATX0601HSO Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Filter Drier P502-8083S (RCD) P502-8163S (RCD) Evaporator Freeze Thermostat KAAFT0101AAA Liquid-Line Solenoid Valve KAALS0101LLS Winter Start Control KAAWS0101AAA Low-Ambient Pressure Switch KSALA0201R22 MotorMaster Control*** 32LT660004 (RCD) 32LT660004 (RCD)(A) 32LT660004 (RCD) Ball Bearing Fan Motor N/A HC38GE231 (RCD) HC38GE231 (RCD)(A) Thermostat Auto Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBNAC01-B Thermostat Auto Changeover, 7-Day Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B Thermidistat TM Control Programmable/Non-Programmable Thermostat with Humidity Control TSTATBBPRH01-B Builder s Thermostat Manual Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B Outdoor Air Temperature Sensor TSTATXXSEN01-B Backplate for Builder s Thermostat TSTATXXBBP01 Backplate for Non-Programmable Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Thermostat Conversion Kit (4 to 5 wire) 10 Pack TSTATXXCNV10 4

SPECIFICATIONS Continued UNIT SIZE-SERIES 048-A/B 060-A/B Operating Weight (Lb) 231/224 264, 260 ELECTRICAL Volts Hertz Phase 208/230 60 1 208/230 60 1 Operating Voltage Range* 187 253 Compressor Rated Load Amps 24.4/19.2 28.8 Locked Rotor Amps 140.0/137.0 148.0/175.0 Condenser Fan Motor Full Load Amps 1.4/1.4 1.4 Min Ampacity for Wire Sizing 31.9/25.4 37.4 Min Wire Size (60 C Copper) AWG 8/10 8 Min Wire Size (75 C Copper) AWG 8/10 8 Max Wire Length (Ft) (60 C Copper) 97/77 82 Max Wire Length (Ft) (75 C Copper) 59/73 78 Max Branch Circuit Fuse Size** 50/40 60 COMPRESSOR AND REFRIGERANT Compressor Type Scroll Manufacturer Millennium/Copeland Copeland/Millennium Temperature and Current Protection Internal Line Break Refrigerant Type R-22 Amount (Lb) 10.45/8.80 12.88 CONDENSER COIL AND FAN Coil Face Area (Sq Ft) 18.7/22.2 22.4 Fins per In. Rows Circuits 20 2 5/25 1 4 23 2 6 Fan Motor (PSC) HP and RPM 1/4 and 1125 1/4 and 1125 Volts Hertz Phase 208/230 60 1 Condenser Airflow (CFM) 3400 3400 OPTIONAL EQUIPMENT Coastal Filter KAACF1101LRG Time-Delay Relay KAATD0101TDR Cycle Protector KSACY0101AAA Crankcase Heater Standard Start Assist Capacitor/Relay Type KSAHS1501AAA KSAHS1601AAA Start Assist PTC Type KAACS0201AAA Sound Hood KSASH2101COP/KSASH0601COP KSASH2101COP TXV (RPB) KAATX0601RPB KAATX0701RPB TXV (Hard Shutoff) KSATX0701HSO Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Filter Drier Standard Evaporator Freeze Thermostat KAAFT0101AAA Liquid-Line Solenoid Valve KAALS0101LLS Winter Start Control KAAWS0101AAA Low-Ambient Pressure Switch KSALA0201R22 MotorMaster Control*** 32LT660004 (RCD) Ball Bearing Fan Motor HC40GE232/HC38G3231(RCD) HC40GE232 (RCD) Thermostat Auto Changeover, Non-Programmable, F/ C, 1-Stage Heat,1-Stage Cool TSTATBBNAC01-B Thermostat Auto Changeover, 7-Day Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B Thermidistat TM Control Programmable/Non-Programmable Thermostat with Humidity Control TSTATBBPRH01-B Builder s Thermostat Manual Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B Outdoor Air Temperature Sensor TSTATXXSEN01-B Backplate for Builder s Thermostat TSTATXXBBP01 Backplate for Non-Programmable Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Thermostat Conversion Kit (4 to 5 wire) 10 Pack TSTATXXCNV10 * Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure. If wire is applied at ambient greater than 30 C (86 F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time-delay fuse or circuit breaker. Charge quantity is for 15 ft of interconnecting tubing. For tubing lengths longer than 15 ft, add 0.6 oz. of refrigerant per ft of tube length in excess of 15 ft. Start assist capacitor and relay required when using liquid solenoid valve or hard shutoff TXV (except 048 and 060). Do not use hard shutoff TXV with liquid solenoid valve. *** Fan motor with ball bearings required. N/A Not applicable in this application. NOTES: All motors/compressors contain internal overload protection. Copper wire must be used from service disconnect to unit. Control circuit is 24v on all units and requires external power source. 5

ACCESSORY USAGE GUIDELINE ACCESSORY REQUIRED FOR LOW-AMBIENT APPLICATIONS (Below 55 F) REQUIRED FOR LONG-LINE APPLICATIONS* (Over 50 Ft) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 Miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Winter Start Control Yes No No Accumulator No No No Compressor Start Assist Capacitor and Relay Yes Yes No MotorMaster Control or Yes No No Low-Ambient Pressure Switch Wind Baffle See Low-Ambient Instructions No No Coastal Filter No No Yes Support Feet Recommended No Recommended Liquid-Line Solenoid Valve or Hard Shutoff TXV * For tubing line sets between 50 and 175 ft, refer to Residential s Split s Long-Line Application Guideline. Only when low-pressure switch is used. Required for Low-Ambient Controller (full modulation feature) and MotorMaster Control only. No See Long-Line Application Guideline Ball Bearing Fan Motor Yes No No No ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) 1. Ball Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. SUGGESTED USE: Required on all units where Low-Ambient Controller (full modulation feature) or MotorMaster Control has been added. 2. Coastal Filter A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow. SUGGESTED USE: In geographic areas where salt damage could occur. 3. Compressor Start Assist Capacitor/Relay Type Start capacitor and start relay gives hard boost to compressor motor at each start-up. SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft. Installations where outdoor design temperature exceeds 105 F (40.6 C). Installations where Liquid-Line Solenoid Valve has been added. 4. Compressor Start Assist PTC Type Solid-state electrical device which gives a soft boost to compressor at each start-up. SUGGESTED USE: Installations with marginal power supply. 5. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control. (Thermostat control standard on 048 and 060 sizes.) SUGGESTED USE: When interconnecting tube length exceeds 50 ft. When unit will be operated below 55 F (12.8 C) outdoor air temperature. Use with Low-Ambient Controller. All commercial installations. 6. Cycle Protector Solid-state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including normal room thermostat cycling. SUGGESTED USE: Installations in areas where power interruptions are frequent. Where user is likely to play with the room thermostat. All commercial installations. Installations where interconnecting tube length exceeds 50 ft. High rise applications. 7. Evaporator Freeze Thermostat An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions. SUGGESTED USE: All units where Winter Start Control has been added. 8. Filter Drier A device for removing contaminants from refrigerant circulating in an air conditioner: 1-direction flow. (Filter drier standard on 048 and 060 sizes.) SUGGESTED USE: All split-system air conditioners. 9. High-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to 400 ± 10 psig and resets at 298 ± 20 psig. Provides protection against compressor damage due to loss of outdoor airflow. To prevent rapid compressor recycling, Cycle Protector can be used with this switch. SUGGESTED USE: Installations exposed to very dirty outdoor air. Installations where condenser inlet air temperature exceeds 125 F (51.7 C). 10. Liquid-Line Solenoid Valve An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration) which stops and starts refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle. NOTE: Compressor Start Assist Capacitor/Relay Type must also be used. SUGGESTED USE: For improved system performance in air conditioners for certain combinations of indoor and outdoor units. Refer to ARI ary Directory. In certain long-line applications. Refer to Residential s Split s Long-Line Application Guideline. 6

ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued 11. Low-Ambient Pressure Switch A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low-ambient temperatures down to 0 F when properly installed. SUGGESTED USE: operation at outdoor temperatures below 55 F (12.8 C). 12. Low-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on low side of refrigerant circuit. Cycles compressor off if refrigerant pressure drops to about 27 psig. Prevents indoor coil freeze-up due to loss of indoor airflow. Provides protection against compressor damage due to loss of refrigerant charge. To prevent rapid compressor recycling, Cycle Protector can be used with this switch. SUGGESTED USE: Where indoor coil is exposed to dirty air. All commercial installations. 13. MotorMaster Control A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to 20 F, it maintains condensing temperature at 100 F ± 10 F. SUGGESTED USE: operation at outdoor temperatures below 55 F. All commercial installations. 14. Outdoor Air Temperature Sensor A device that allows the temperature at a remote location (outdoors) to be displayed at the thermostat. SUGGESTED USE: All Bryant programmable thermostats. 15. Sound Hood Wraparound sound attenuation cover for the compressor. Reduces unit sound level by about 2 dba. SUGGESTED USE: installed closer than 15 ft to quiet areas bedrooms, etc. installed between 2 houses less than 10 ft apart. 16. Thermostatic Expansion Valve (TXV) A modulating flow control valve which meters refrigerant flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shutoff and RPB type valves are available. Do not use hard shutoff TXV with Liquid-Line Solenoid Valve. SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI ary Directory. Required for use on all zoning systems. 17. Time-Delay Relay An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off. SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI ary Directory. Required for use on all zoning systems. 18. Winter Start Control An SPST delay relay which bypasses the low-pressure switch for approximately 3 minutes to permit start-up for cooling operation under low-load conditions. SUGGESTED USE: All air conditioners where Low-Ambient Controller has been added. SOUND POWER (dba) A-WTD, WITHOUT PURETONE PENALTY UNIT SOUND OCTAVE BAND CENTER FREQUENCY (Hz) SIZE LEVEL (dba) 125 250 500 1000 2000 4000 8000 018-A 76 47.9.7 63.3 71.9 63.8 59.44 53.9 024-A 78 49.5 58.0 64.0 71.0 64.5 60.5 56.5 030-A 78 54.0 61.0 66.0 70.5 66.0.5 58.0 036-A 82 52.0 58.5 68.0 78.0 68.0 64.0 58.0 036-B 82 54.5 66.5 68.0 71.0 77.0 70.5 61.5 042-A 82 54.0 61.0.5 73.5 71.0 63.5 58.5 042-B 82 55.0 69.0.0 70.5 76.5 68.5 61.5 048-A 82 52.5.5.0 70.0 64.5 63.5 58.5 048-B 82 51.5 58.5 65.5 66.5 64.0 64.5 61.5 060-A 82 58.0 69.0.0 75.0 69.5 70.0 64.5 060-B 82 58.5 66.0 71.5 75.0 68.5 68.0 60.5 7

UNIT SIZE-SERIES 018-A 024-A See notes on page 14. COMBINATION RATINGS SEER FACTORY- BRYANT GAS SUPPLIED FURNACE OR ACCESSORY INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY MODEL BTUH MENT RATING TDR LLS TXV EER CC5A/CD5AA018* 17,000 NONE 12 12 12 10.9 CC5A/CD5AA024 17,600 NONE 12 12 12 11.1 CC5A/CD5AW024 17,600 NONE 12 12 12 11.1 CE3AA024 17,600 NONE 12 12 12 11.15 CF5AA024 17,600 NONE 12 12 12 11.15 CK3BA024 17,600 NONE 12 12 12 11.3 CK5A/CK5BA018 17,000 NONE 12 12 12 11.05 CK5A/CK5BA024 17,600 NONE 12 12 12 11.3 CK5A/CK5BW024 17,600 NONE 12 12 12 11.3 F(A,B)4(A,B)N(F,C)018 17,000 TDR 12 12 11.1 F(A,B)4(A,B)N(F,C)024 17,600 TDR 12.5 12.5 11.4 FC4(B,C)NF024 17,600 TDR&TXV 12.5 11.6 FF1DNA018 17,000 TDR 12 12 11.4 FF1DNA024 17,600 TDR 12 12 11.25 FF1DNE018 17,000 TDR&TXV 12 11.45 FF1DNE024 17,600 TDR&TXV 12 11.45 FG3AAA024 17,600 NONE 12 12 12 11.1 FK4(C,D)NF001 17,800 TDR&TXV 13 12.9 FK4(C,D)NF002 18,000 TDR&TXV 14 13.1 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA018 17,000 TDR 13 13 12.1 CC5A/CD5AA024 17,600 TDR 13.5 13.5 12.45 CC5A/CD5AW024 17,600 TDR 13.5 13.5 12.45 CE3AA024 17,600 TDR 13 13 12.45 CK3BA024 17,600 TDR 13.5 13.5 12.6 CK5A/CK5BA018 17,000 TDR 13 13 12.35 CK5A/CK5BA024 17,600 TDR 13.5 13.5 12.6 CK5A/CK5BW024 17,600 TDR 13.5 13.5 12.6 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AW024 17,600 TDR 13.5 13.5 12.25 CE3AA024 17,600 TDR 13 13 12.25 CK5A/CK5BW024 17,600 TDR 13.5 13.5 12.45 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AW024 17,600 TDR 13.5 13.5 12.35 CE3AA024 17,600 TDR 13 13 12.2 CCC5A/CD5AA024* 23,000 NONE 12 12 12 10.9 CC5A/CD5AA030 23,400 NONE 12.1 12.1 12.1 10.9 CC5A/CD5AW024 23,000 NONE 12 12 12 10.9 CC5A/CD5AW030 23,400 NONE 12.1 12.1 12.1 10.9 CE3AA024 23,400 NONE 12 12 12 10.95 CE3AA030 23,600 NONE 12.1 12.1 12.1 11.05 CF5AA024 23,400 NONE 12 12 12 10.9 CK3BA024 23,000 NONE 12 12 12 11.05 CK3BA030 23,400 NONE 12.1 12.1 12.1 11 CK5A/CK5BA024 23,000 NONE 12 12 12 11.05 CK5A/CK5BA030 23,400 NONE 12.1 12.1 12.1 11 CK5A/CK5BW024 23,000 NONE 12 12 12 11.05 CK5A/CK5BW030 23,400 NONE 12.1 12.1 12.1 11 F(A,B)4(A,B)N(F,C)024 23,200 TDR 12 12 11.1 F(A,B)4(A,B)N(F,C)030 23,600 TDR 12.2 12.2 11.25 FC4(B,C)NF024 23,200 TDR&TXV 12 11.15 FC4(B,C)NF030 23,600 TDR&TXV 12.2 11.3 FF1DNA024 23,200 TDR 12 12 10.95 FF1DNA030 23,400 TDR 12.2 12.2 11.05 FF1DNE024 23,200 TDR&TXV 12 10.85 FF1DNE030 23,400 TDR&TXV 12.2 11 FG3AAA024 23,000 NONE 11.5 11.5 11.5 10.8 FK4(C,D)NF001 23,800 TDR&TXV 13 12.35 FK4(C,D)NF002 23,800 TDR&TXV 13.5 12.5 FK4(C,D)NF003 23,800 TDR&TXV 14 12.75 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA024 23,200 TDR 13 13 12 CC5A/CD5AA030 23,400 TDR 13 13 12.2 CC5A/CD5AW024 23,200 TDR 13 13 12 CC5A/CD5AW030 23,400 TDR 13 13 12.2 CE3AA024 23,200 TDR 13 13 12.05 CE3AA030 23,400 TDR 13 13 12.3 CK3BA024 23,200 TDR 13 13 12.2 CK3BA030 23,400 TDR 13 13 12.2 CK5A/CK5BA024 23,200 TDR 13 13 12.2 CK5A/CK5BA030 23,400 TDR 13 13 12.2 CK5A/CK5BW024 23,200 TDR 13 13 12.2 CK5A/CK5BW030 23,400 TDR 13 13 12.2 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AW024 23,200 TDR 13 13 11.75 CC5A/CD5AW030 23,400 TDR 13 13 11.95 CE3AA024 23,200 TDR 13 13 11.8 CE3AA030 23,400 TDR 13 13 12 CK3BA024 23,200 TDR 13 13 11.9 CK3BA030 23,400 TDR 13 13 11.95 CK5A/CK5BW024 23,200 TDR 13 13 11.9 CK5A/CK5BW030 23,400 TDR 13 13 11.95 8

UNIT SIZE-SERIES 024-A 030-A See notes on page 14. COMBINATION RATINGS Continued FACTORY- SUPPLIED ENHANCE- MENT 9 SEER BRYANT GAS FURNACE OR ACCESSORY TDR ACCESSORY INDOOR MODEL TOT. CAP. BTUH STANDARD RATING LLS TXV EER COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AW024 23,200 TDR 13 13 11.9 CC5A/CD5AW030 23,400 TDR 13 13 12.1 CE3AA024 23,200 TDR 13 13 11.9 CE3AA030 23,400 TDR 13 13 12.15 CK3BA024 23,200 TDR 13 13 12.2 CK3BA030 23,400 TDR 13 13 12.2 CK5A/CK5BW024 23,200 TDR 13 13 12.2 CK5A/CK5BW030 23,400 TDR 13 13 12.2 CC5A/CD5AA030* 29,000 NONE 12.00 12.00 12.00 10.70 CC5A/CD5AA036 29,600 NONE 12.20 12.20 12.20 11.15 CC5A/CD5AW030 29,000 NONE 12.00 12.00 12.00 10.70 CD5AW036 29,600 NONE 12.20 12.20 12.20 11.15 CE3AA030 29,000 NONE 12.00 12.00 12.00 10.85 CE3AA036 29,600 NONE 12.20 12.20 12.20 10.95 CF5AA036 29,600 NONE 12.20 12.20 12.20 11.05 CK3BA030 29,000 NONE 12.00 12.00 12.00 10.75 CK3BA036 29,600 NONE 12.20 12.20 12.20 11.15 CK5A/CK5BA030 29,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BA036 29,600 NONE 12.20 12.20 12.20 11.15 CK5A/CK5BN036 27,600 NONE 12.20 12.20 12.20 11.15 CK5A/CK5BW030 29,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BW036 29,600 NONE 12.20 12.20 12.20 11.15 F(A,B)4(A,B)N(F,C)030 29,200 TDR 12.10 12.10 10.90 F(A,B)4(A,B)N(F,C)036 29,600 TDR 12.00 12.00 10.85 FC4(B,C)NF030 29,200 TDR & TXV 12.10 10.90 FC4(B,C)NF036 29,600 TDR & TXV 12.00 10.85 FC4(B,C)NF033 30,000 TDR & TXV 12.50 11.20 FF1DNA030 29,000 TDR 12.00 12.00 10.85 FG3AAA036 29,600 NONE 12.00 12.00 12.00 10.85 FK4(C,D)NF001 29,400 TDR & TXV 13.00 11.80 FK4(C,D)NF002 29,400 TDR & TXV 13.00 11.90 FK4(C,D)NF003 29,800 TDR & TXV 13.50 12.35 FK4(C,D)NF005 30,000 TDR & TXV 14.00 12.85 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA030 29,000 TDR 13 13 11.45 CC5A/CD5AA036 29,600 TDR 13.5 13.5 11.9 CC5A/CD5AW030 29,000 TDR 13 13 11.45 CE3AA030 29,000 TDR 13 13 11.65 CE3AA036 29,600 TDR 13 13 11.7 CK3BA030 29,000 TDR 13 13 11.5 CK3BA036 29,600 TDR 13.5 13.5 11.9 CK5A/CK5BA030 29,000 TDR 13 13 11.5 CK5A/CK5BA036 29,600 TDR 13.5 13.5 11.9 CK5A/CK5BT036 29,600 TDR 13.5 13.5 11.9 CK5A/CK5BW030 29,000 TDR 13 13 11.5 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA030 29,000 TDR 13 13 11.6 CC5A/CD5AA036 29,600 TDR 13.5 13.5 12.05 CC5A/CD5AW030 29,000 TDR 13 13 11.6 CC5A/CD5AW036 29,600 TDR 13.5 13.5 12.05 CE3AA030 29,000 TDR 13 13 11.8 CE3AA036 29,600 TDR 13 13 11.9 CK3BA030 29,000 TDR 13 13 11.65 CK3BA036 29,600 TDR 13.5 13.5 12.05 CK5A/CK5BA030 29,000 TDR 13 13 11.65 CK5A/CK5BA036 29,600 TDR 13.5 13.5 12.05 CK5A/CK5BW030 29,000 TDR 13 13 11.65 CK5A/CK5BW036 29,600 TDR 13.5 13.5 12.05 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AA030 29,000 TDR 12.80 12.80 11.35 CC5A/CD5AA036 29,600 TDR 13.00 13.00 11.85 CC5A/CD5AW030 29,000 TDR 12.80 12.80 11.35 CD5AW036 29,600 TDR 13.00 13.00 11.85 CK3BA030 29,000 TDR 12.50 12.50 11.25 CK3BA036 29,600 TDR 13.00 13.00 11.85 CK5A/CK5BW030 29,000 TDR 12.50 12.50 11.25 CK5A/CK5BW036 29,600 TDR 13.00 13.00 11.85 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA030 29,000 TDR 12.80 12.80 11.35 CC5A/CD5AA036 29,600 TDR 13.00 13.00 11.85 CC5A/CD5AW030 29,000 TDR 12.80 12.80 11.35 CD5AW036 29,600 TDR 13.00 13.00 11.85 CK3BA030 29,000 TDR 12.80 12.80 11.25 CK3BA036 29,600 TDR 13.00 13.00 11.85 CK5A/CK5BA036 29,600 TDR 13.00 13.00 11.85 CK5A/CK5BW030 29,000 TDR 12.80 12.80 11.25 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA030 29,000 TDR 12.80 12.80 11.35 CC5A/CD5AA036 29,600 TDR 13.00 13.00 11.85 CC5A/CD5AW030 29,000 TDR 12.80 12.80 11.35

UNIT SIZE-SERIES 030-A 036-A, B See notes on page 14. COMBINATION RATINGS Continued SEER FACTORY- BRYANT GAS SUPPLIED FURNACE OR ACCESSORY INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY MODEL BTUH MENT RATING TDR LLS TXV EER CD5AW036 29,600 TDR 13.00 13.00 11.85 CK3BA030 29,000 TDR 12.80 12.80 11.35 CK3BA036 29,600 TDR 13.00 13.00 11.95 CK5A/CK5BW030 29,000 TDR 12.80 12.80 11.35 CK5A/CK5BW036 29,600 TDR 13.00 13.00 11.95 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CK3BA030 29,000 TDR 12.50 12.50 11.20 CK3BA036 29,600 TDR 13.00 13.00 11.80 CK5A/CK5BW030 29,000 TDR 12.50 12.50 11.20 CK5A/CK5BW036 29,600 TDR 13.00 13.00 11.80 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CK3BA030 29,000 TDR 13.00 13.00 11.60 CK3BA036 29,600 TDR 13.00 13.00 12.20 CK5A/CK5BW030 29,000 TDR 13.00 13.00 11.60 CK5A/CK5BW036 29,600 TDR 13.00 13.00 12.20 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CK3BA030 29,000 TDR 13.00 13.00 11.55 CK3BA036 29,600 TDR 13.00 13.00 12.15 CK5A/CK5BW036 29,600 TDR 13.00 13.00 12.15 CC5A/CD5AA036* 35,000 NONE 12.00 12.00 12.00 10.75 CC5A/CD5AA042 35,000 NONE 12.00 12.00 12.00 10.75 CC5A/CD5AW036 35,000 NONE 12.00 12.00 12.00 10.75 CC5A/CD5AW042 35,000 NONE 12.00 12.00 12.00 10.70 CE3AA036 35,000 NONE 11.80 11.80 11.80 10.65 CE3AA042 35,400 NONE 12.10 12.10 12.10 10.80 CF5AA036 35,000 NONE 12.00 12.00 12.00 10.70 CK3BA036 35,000 NONE 12.00 12.00 12.00 10.75 CK3BA042 35,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BA036 35,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BA042 35,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BN036 33,000 NONE 12.00 12.00 12.00 10.85 CK5A/CK5BN042 33,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BT036 35,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BT042 35,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BW036 35,000 NONE 12.00 12.00 12.00 10.75 F(A,B)4(A,B)N(F,B,C)042 35,400 TDR 12.00 12.00 10.70 F(A,B)4(A,B)N(F,C)036 35,000 TDR 11.50 11.50 10.45 FC4(B,C)N(F,B)042 35,400 TDR & TXV 12.00 10.70 FC4(B,C)NF036 35,000 TDR & TXV 11.50 10.45 FG3AAA036 34,600 NONE 11.80 11.80 11.80 10.55 FK4(C,D)NB006 36,000 TDR & TXV 14.00 12.40 FK4(C,D)NF001 34,400 TDR & TXV 12.00 11.15 FK4(C,D)NF002 34,600 TDR & TXV 12.00 11.20 FK4(C,D)NF003 35,000 TDR & TXV 13.00 11.70 FK4(C,D)NF005 35,600 TDR & TXV 13.50 12.15 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 12.5 12.5 11.2 CE3AA036 34,600 TDR 12.5 12.5 11.1 CE3AA042 35,000 TDR 12.5 12.5 11.35 CK3BA036 35,000 TDR 12.5 12.5 11.25 CK5A/CK5BA036 35,000 TDR 12.5 12.5 11.25 CK5A/CK5BE042 35,000 TDR 13 13 11.35 CK5A/CK5BT036 35,000 TDR 12.5 12.5 11.25 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 12.5 12.5 11.35 CC5A/CD5AA042 35,000 TDR 13 13 11.5 CC5A/CD5AW036 35,000 TDR 12.5 12.5 11.35 CE3AA036 34,600 TDR 12.5 12.5 11.25 CE3AA042 35,000 TDR 12.5 12.5 11.5 CK3BA036 35,000 TDR 12.5 12.5 11.45 CK3BA042 35,000 TDR 13 13 11.5 CK5A/CK5BA036 35,000 TDR 12.5 12.5 11.45 CK5A/CK5BA042 35,000 TDR 13 13 11.5 CK5A/CK5BE042 35,000 TDR 13 13 11.55 CK5A/CK5BT036 35,000 TDR 12.5 12.5 11.45 CK5A/CK5BT042 35,000 TDR 13 13 11.5 CK5A/CK5BW036 35,000 TDR 12.5 12.5 11.45 COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 12.5 12.5 11.45 CC5A/CD5AA042 35,000 TDR 13 13 11.6 CC5A/CD5AW036 35,000 TDR 12.5 12.5 11.45 CC5A/CD5AW042 35,000 TDR 13 13 11.5 CE3AA036 34,600 TDR 12.5 12.5 11.35 CE3AA042 35,000 TDR 12.5 12.5 11.6 CK3BA036 35,000 TDR 12.5 12.5 11.5 CK3BA042 35,000 TDR 13 13 11.55 CK5A/CK5BA036 35,000 TDR 12.5 12.5 11.5 CK5A/CK5BA042 35,000 TDR 13 13 11.55 CK5A/CK5BT036 35,000 TDR 12.5 12.5 11.5 CK5A/CK5BT042 35,000 TDR 13 13 11.55 CK5A/CK5BW036 35,000 TDR 12.5 12.5 11.5 10

UNIT SIZE-SERIES 036-A, B 042-A, B See notes on page 14. COMBINATION RATINGS Continued FACTORY- SUPPLIED ENHANCE- MENT 11 SEER BRYANT GAS FURNACE OR ACCESSORY TDR ACCESSORY INDOOR MODEL TOT. CAP. BTUH STANDARD RATING LLS TXV EER COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AA042 35,000 TDR 13 13 11.55 CC5A/CD5AW036 35,000 TDR 12.5 12.5 11.4 CC5A/CD5AW042 35,000 TDR 13 13 11.5 CE3AA036 34,600 TDR 12.5 12.5 11.3 CE3AA042 35,000 TDR 12.5 12.5 11.55 CK3BA042 35,000 TDR 13 13 11.5 CK5A/CK5BA042 35,000 TDR 13 13 11.5 CK5A/CK5BT042 35,000 TDR 13 13 11.5 CK5A/CK5BW036 35,000 TDR 12.5 12.5 11.45 COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AA042 35,000 TDR 13 13 11.65 CC5A/CD5AW036 35,000 TDR 12.5 12.5 11.45 CC5A/CD5AW042 35,000 TDR 13 13 11.6 CE3AA036 34,600 TDR 12.5 12.5 11.35 CE3AA042 35,000 TDR 12.5 12.5 11.65 CK3BA042 35,000 TDR 13 13 11.6 CK5A/CK5BA042 35,000 TDR 13 13 11.6 CK5A/CK5BT042 35,000 TDR 13 13 11.6 CK5A/CK5BW036 35,000 TDR 12.5 12.5 11.5 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 12.50 12.50 11.00 CC5A/CD5AA042 35,000 TDR 12.50 12.50 11.10 CC5A/CD5AW036 35,000 TDR 12.50 12.50 11.00 CK3BA036 35,000 TDR 12.50 12.50 11.00 CK3BA042 35,000 TDR 12.50 12.50 11.15 CK5A/CK5BA036 35,000 TDR 12.50 12.50 11.00 CK5A/CK5BN042 34,000 TDR 12.50 12.50 11.15 CK5A/CK5BT036 35,000 TDR 12.50 12.50 11.00 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 12.80 12.80 11.20 CC5A/CD5AA042 35,000 TDR 12.80 12.80 11.35 CC5A/CD5AW036 35,000 TDR 12.80 12.80 11.20 CC5A/CD5AW042 35,000 TDR 12.80 12.80 11.25 CK5A/CK5BA042 35,000 TDR 12.80 12.80 11.25 CK5A/CK5BT042 35,000 TDR 12.80 12.80 11.25 CK5A/CK5BW036 35,000 TDR 12.50 12.50 11.10 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CK3BA036 35,000 TDR 12.50 12.50 11.00 CK3BA042 35,000 TDR 12.50 12.50 11.15 CK5A/CK5BA042 35,000 TDR 12.50 12.50 11.15 CK5A/CK5BT042 35,000 TDR 12.50 12.50 11.15 CK5A/CK5BW036 35,000 TDR 12.50 12.50 11.00 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 12.80 12.80 11.25 CC5A/CD5AA042 35,000 TDR 13.00 13.00 11.40 CC5A/CD5AW036 35,000 TDR 12.80 12.80 11.25 CC5A/CD5AW042 35,000 TDR 13.00 13.00 11.35 CK3BA036 35,000 TDR 12.80 12.80 11.30 CK3BA042 35,000 TDR 13.00 13.00 11.45 CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.45 CK5A/CK5BT042 35,000 TDR 13.00 13.00 11.45 CK5A/CK5BW036 35,000 TDR 12.80 12.80 11.30 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.45 CK5A/CK5BT042 35,000 TDR 13.00 13.00 11.45 CK5A/CK5BW036 35,000 TDR 12.80 12.80 11.35 CC5A/CD5AA042* 40,000 NONE 12.00 12.00 12.00 10.45 CC5A/CD5AC048 40,000 NONE 12.00 12.00 12.00 10.35 CC5A/CD5AW042 40,000 NONE 12.00 12.00 12.00 10.35 CC5A/CD5AW048 40,500 NONE 12.00 12.00 12.00 10.45 CD5AA048 40,500 NONE 12.00 12.00 12.00 10.45 CE3AA042 40,000 NONE 12.00 12.00 12.00 10.50 CE3AA048 40,500 NONE 12.00 12.00 12.00 10.55 CF5AA048 40,500 NONE 12.00 12.00 12.00 10.45 CK3BA042 40,000 NONE 12.00 12.00 12.00 10.45 CK3BA048 40,500 NONE 12.00 12.00 12.00 10.50 CK5A/CK5BA042 40,000 NONE 12.00 12.00 12.00 10.45 CK5A/CK5BA048 40,500 NONE 12.00 12.00 12.00 10.50 CK5A/CK5BN042 39,000 NONE 12.00 12.00 12.00 10.45 CK5A/CK5BN048 39,500 NONE 12.00 12.00 12.00 10.50 CK5A/CK5BT042 40,000 NONE 12.00 12.00 12.00 10.45 CK5A/CK5BT048 40,500 NONE 12.00 12.00 12.00 10.50 CK5A/CK5BW048 40,500 NONE 12.00 12.00 12.00 10.50 F(A,B)4(A,B)N(F,B,C)042 40,000 TDR 11.50 11.50 10.30 F(A,B)4(A,B)N(F,B,C)048 40,500 TDR 12.00 12.00 10.50 FC4(B,C)N(F,B)042 40,000 TDR & TXV 11.50 10.30 FC4(B,C)N(F,B)048 40,500 TDR & TXV 12.00 10.50 FC4(B,C)NB054 42,000 TDR & TXV 12.50 11.15 FG3AAA048 40,500 NONE 12.00 12.00 12.00 10.40 FK4(C,D)NB006 42,000 TDR & TXV 14.00 12.00 FK4(C,D)NF003 41,000 TDR & TXV 12.50 11.15 FK4(C,D)NF005 41,500 TDR & TXV 13.00 11.65

COMBINATION RATINGS Continued UNIT SIZE-SERIES 042-A, B See notes on page 14. SEER FACTORY- BRYANT GAS SUPPLIED FURNACE OR ACCESSORY INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY MODEL BTUH MENT RATING TDR LLS TXV EER COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 12.5 12.5 11.2 CC5A/CD5AC048 40,000 TDR 12.5 12.5 11.2 CD5AA048 40,500 TDR 13 13 11.35 CE3AA042 40,000 TDR 12.5 12.5 11.3 CE3AA048 40,500 TDR 12.5 12.5 11.35 CK3BA042 40,000 TDR 12.5 12.5 11.25 CK3BA048 40,500 TDR 13 13 11.35 CK5A/CK5BA042 40,000 TDR 12.5 12.5 11.25 CK5A/CK5BA048 40,500 TDR 13 13 11.35 CK5A/CK5BE042 40,500 TDR 13 13 11.3 CK5A/CK5BT042 40,000 TDR 12.5 12.5 11.25 CK5A/CK5BT048 40,500 TDR 13 13 11.35 COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 12.5 12.5 11.3 CC5A/CD5AC048 40,000 TDR 12.5 12.5 11.3 CC5A/CD5AW042 40,000 TDR 12.5 12.5 11.25 CC5A/CD5AW048 40,500 TDR 13 13 11.5 CD5AA048 40,500 TDR 13 13 11.5 CE3AA042 40,000 TDR 12.5 12.5 11.4 CE3AA048 40,500 TDR 12.5 12.5 11.45 CK3BA042 40,000 TDR 12.5 12.5 11.35 CK3BA048 40,500 TDR 13 13 11.5 CK5A/CK5BA042 40,000 TDR 12.5 12.5 11.35 CK5A/CK5BA048 40,500 TDR 13 13 11.5 CK5A/CK5BT042 40,000 TDR 12.5 12.5 11.35 CK5A/CK5BT048 40,500 TDR 13 13 11.5 CK5A/CK5BW048 40,500 TDR 13 13 11.5 COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 12.5 12.5 11.3 CC5A/CD5AC048 40,000 TDR 12.5 12.5 11.35 CC5A/CD5AW042 40,000 TDR 12.5 12.5 11.25 CC5A/CD5AW048 40,500 TDR 13 13 11.5 CD5AA048 40,500 TDR 13 13 11.5 CE3AA042 40,000 TDR 12.5 12.5 11.4 CE3AA048 40,500 TDR 12.5 12.5 11.45 CK3BA042 40,000 TDR 12.5 12.5 11.35 CK3BA048 40,500 TDR 13 13 11.5 CK5A/CK5BA042 40,000 TDR 12.5 12.5 11.35 CK5A/CK5BA048 40,500 TDR 13 13 11.5 CK5A/CK5BT042 40,000 TDR 12.5 12.5 11.35 CK5A/CK5BT048 40,500 TDR 13 13 11.5 CK5A/CK5BW048 40,500 TDR 13 13 11.5 COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 12.5 12.5 11.35 CC5A/CD5AC048 40,000 TDR 12.5 12.5 11.35 CC5A/CD5AW042 40,000 TDR 12.5 12.5 11.25 CC5A/CD5AW048 40,500 TDR 13 13 11.55 CD5AA048 40,500 TDR 13 13 11.55 CE3AA042 40,000 TDR 12.5 12.5 11.45 CE3AA048 40,500 TDR 12.5 12.5 11.5 CK3BA042 40,000 TDR 12.5 12.5 11.4 CK3BA048 40,500 TDR 13 13 11.55 CK5A/CK5BA042 40,000 TDR 12.5 12.5 11.4 CK5A/CK5BA048 40,500 TDR 13 13 11.55 CK5A/CK5BT042 40,000 TDR 12.5 12.5 11.4 CK5A/CK5BT048 40,500 TDR 13 13 11.55 CK5A/CK5BW048 40,500 TDR 13 13 11.55 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 12.50 12.50 10.95 CC5A/CD5AW042 40,000 TDR 12.50 12.50 10.85 CC5A/CD5AW048 40,000 TDR 12.50 12.50 11.05 CD5AA048 40,000 TDR 13.00 13.00 11.05 CK3BA048 40,000 TDR 12.50 12.15 11.00 CK5A/CK5BA048 40,000 TDR 12.50 12.50 11.00 CK5A/CK5BT048 40,000 TDR 12.50 12.50 11.00 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CK3BA048 40,500 TDR 12.30 12.30 10.85 CK5A/CK5BA048 40,500 TDR 12.30 12.30 10.85 CK5A/CK5BT048 40,500 TDR 12.30 12.30 10.85 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 12.50 12.50 11.00 CC5A/CD5AW042 40,000 TDR 12.50 12.50 10.90 CC5A/CD5AW048 40,000 TDR 13.00 13.00 11.10 CD5AA048 40,000 TDR 13.00 13.00 11.10 CK3BA048 40,500 TDR 13.00 13.00 11.20 CK5A/CK5BA048 40,500 TDR 13.00 13.00 11.20 CK5A/CK5BT048 40,500 TDR 13.00 13.00 11.20 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CK5A/CK5BW048 40,500 TDR 13.00 13.00 11.20 12

UNIT SIZE-SERIES 048-A, B See notes on page 14. COMBINATION RATINGS Continued FACTORY- SUPPLIED ENHANCE- MENT 13 SEER BRYANT GAS FURNACE OR ACCESSORY TDR ACCESSORY INDOOR MODEL TOT. CAP. BTUH STANDARD RATING LLS TXV EER CD5AA048* 47,000 NONE 12 12 12 10.75 CC5A/CD5AC048 46,000 NONE 11.8 11.8 11.8 10.65 CC5A/CD5AW048 47,000 NONE 12 12 12 10.75 CC5A/CD5AA060 47,500 NONE 12.1 12.1 12.1 10.75 CC5A/CD5AW060 47,500 NONE 12.2 12.2 12.2 11 CK5A/CK5BA048 47,000 NONE 12 12 12 10.8 CK3BA048 47,000 NONE 12 12 12 10.75 CK5A/CK5BW048 47,000 NONE 12 12 12 10.8 CK5A/CK5BT048 47,000 NONE 12 12 12 10.75 CK5A/CK5BA060 47,500 NONE 12.1 12.1 12.1 11 CK3BA060 47,500 NONE 12.1 12.1 12.1 11 CK5A/CK5BT060 47,500 NONE 12.1 12.1 12.1 11 CK5A/CK5BX060 47,500 NONE 12.2 12.2 12.2 11.1 CE3AA048 47,000 NONE 12 12 12 10.8 CE3AA060 47,500 NONE 12.1 12.1 12.1 11 CF5AA048 47,000 NONE 12 12 12 10.8 F(A,B)4(A,B)N(F,B,C)048 47,000 TDR 12 12 10.85 F(A,B)4(A,B)N(F,B,C)060 47,500 TDR 12.1 12.1 10.9 FB4(A,B)NB070 47,500 TDR 12.2 12.2 11.1 FC4(B,C)N(F,B)048 47,000 TDR&TXV 12 10.85 FC4(B,C)NB054 48,000 TDR&TXV 12.5 11.2 FC4(B,C)NB070 47,500 TDR&TXV 12.2 11.15 FC4(B,C)N(F,B)060 47,500 TDR&TXV 12.1 10.95 FG3AAA048 47,000 NONE 12 12 12 10.7 FG3AAA060 48,000 NONE 12.2 12.2 12.2 10.9 FK4(C,D)NF005 47,000 TDR&TXV 13.5 12.15 FK4(C,D)NB006 48,000 TDR&TXV 14 12.45 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AC048 46,500 TDR 12.3 12.3 11.05 CD5AA048 47,000 TDR 12.5 12.5 11.2 CE3AA048 46,000 TDR 12.5 12.5 11.15 CE3AA060 47,000 TDR 12.5 12.5 11.45 CK3BA048 46,500 TDR 12.5 12.5 11.2 CK5A/CK5BA048 46,500 TDR 12.5 12.5 11.2 CK5A/CK5BT048 46,500 TDR 12.5 12.5 11.2 COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE CC5A/CD5AA060 47,000 TDR 12.5 12.5 11.4 CC5A/CD5AC048 46,000 TDR 12.3 12.3 11.25 CC5A/CD5AW048 46,500 TDR 12.5 12.5 11.4 CD5AA048 46,500 TDR 12.5 12.5 11.4 CE3AA048 46,000 TDR 12.5 12.5 11.4 CE3AA060 47,000 TDR 13 13 11.7 CK3BA048 46,500 TDR 12.5 12.5 11.4 CK3BA060 47,000 TDR 12.5 12.5 11.7 CK5A/CK5BA048 46,500 TDR 12.5 12.5 11.4 CK5A/CK5BA060 47,000 TDR 12.5 12.5 11.7 CK5A/CK5BT048 46,500 TDR 12.5 12.5 11.4 CK5A/CK5BT060 47,000 TDR 12.5 12.5 11.7 CK5A/CK5BW048 46,500 TDR 12.5 12.5 11.4 CK5A/CK5BX060 47,500 TDR 13 13 11.9 COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AA060 47,000 TDR 12.5 12.5 11.35 CC5A/CD5AC048 46,000 TDR 12.3 12.3 11.2 CC5A/CD5AW048 46,500 TDR 12.5 12.5 11.35 CC5A/CD5AW060 47,500 TDR 13 13 11.7 CD5AA048 46,500 TDR 12.5 12.5 11.35 CE3AA048 46,000 TDR 12.5 12.5 11.3 CE3AA060 47,000 TDR 13 13 11.65 CK3BA048 46,500 TDR 12.5 12.5 11.35 CK3BA060 47,000 TDR 12.5 12.5 11.65 CK5A/CK5BA048 46,500 TDR 12.5 12.5 11.35 CK5A/CK5BA060 47,000 TDR 12.5 12.5 11.65 CK5A/CK5BT048 46,500 TDR 12.5 12.5 11.35 CK5A/CK5BT060 47,000 TDR 12.5 12.5 11.65 CK5A/CK5BW048 46,500 TDR 12.5 12.5 11.35 CK5A/CK5BX060 47,500 TDR 13 13 11.85 COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AA060 47,000 TDR 12.5 12.5 11.5 CC5A/CD5AC048 46,500 TDR 12.3 12.3 11.35 CC5A/CD5AW048 46,500 TDR 12.5 12.5 11.45 CC5A/CD5AW060 47,500 TDR 13 13 11.75 CD5AA048 46,500 TDR 12.5 12.5 11.45 CE3AA048 46,000 TDR 12.5 12.5 11.4 CE3AA060 47,000 TDR 13 13 11.75 CK3BA048 46,500 TDR 12.5 12.5 11.45 CK3BA060 47,000 TDR 12.5 12.5 11.75 CK5A/CK5BA048 46,500 TDR 12.5 12.5 11.45 CK5A/CK5BA060 47,000 TDR 12.5 12.5 11.75 CK5A/CK5BT048 46,500 TDR 12.5 12.5 11.45 CK5A/CK5BT060 47,000 TDR 12.5 12.5 11.75 CK5A/CK5BW048 46,500 TDR 12.5 12.5 11.45 CK5A/CK5BX060 47,500 TDR 13 13 11.9

UNIT SIZE-SERIES 048-A, B COMBINATION RATINGS Continued SEER FACTORY- BRYANT GAS SUPPLIED FURNACE OR INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY ACCESSORY MODEL BTUH MENT RATING TDR LLS TXV EER COILS + 355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AA060 47,000 TDR 12.1 12.1 10.8 CC5A/CD5AW060 47,500 TDR 12.5 12.5 11.15 CE3AA060 47,000 TDR 12.2 12.2 11.15 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA060 47,000 TDR 12.1 12.1 10.8 CC5A/CD5AW060 47,500 TDR 12.5 12.5 11.15 CE3AA060 47,000 TDR 12.2 12.2 11.15 CK3BA060 47,000 TDR 12.5 12.5 11.55 CK5A/CK5BA060 47,000 TDR 12.5 12.5 11.55 CK5A/CK5BT060 47,000 TDR 12.5 12.5 11.55 CK5A/CK5BX060 47,500 TDR 12.5 12.5 11.25 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CC5A/CD5AA060 47,000 TDR 12 12 10.8 CC5A/CD5AW060 47,500 TDR 12.5 12.5 11.15 CE3AA060 47,000 TDR 12.2 12.2 11.1 CK3BA048 46,500 TDR 12.1 12.1 10.85 CK3BA060 47,000 TDR 12.5 12.5 11.15 CK5A/CK5BA048 46,500 TDR 12.1 12.1 10.85 CK5A/CK5BA060 47,000 TDR 12.5 12.5 11.1 CK5A/CK5BT048 46,500 TDR 12.1 12.1 10.85 CK5A/CK5BT060 47,000 TDR 12.5 12.5 11.15 CK5A/CK5BW048 46,500 TDR 12.1 12.1 10.85 CK5A/CK5BX060 47,500 TDR 12.5 12.5 11.35 CC5A/CD5AW060* 58,000 NONE 12.00 12.00 12.00 10.70 CC5A/CD5AA060 56,000 NONE 11.50 11.50 11.50 10.50 CE3AA060 58,000 NONE 12.00 12.00 12.00 10.80 CK3BA060 56,000 NONE 12.00 12.00 12.00 10.60 CK5A/CK5BA060 56,000 NONE 11.50 11.50 11.50 10.60 CK5A/CK5BN060 56,000 NONE 11.50 11.50 11.50 10.95 CK5A/CK5BT060 56,000 NONE 11.50 11.50 11.50 10.45 CK5A/CK5BX060 58,000 NONE 12.00 12.00 12.00 10.90 F(A,B)4(A,B)N(F,B,C)060 58,000 TDR 11.50 11.50 10.40 FB4(A,B)NB070 58,500 TDR 12.00 12.00 10.85 FC4(B,C)N(F,B)060 58,000 TDR & TXV 11.50 10.40 FC4(B,C)NB070 58,500 TDR & TXV 12.00 10.85 FK4(C,D)NB006 59,000 TDR & TXV 13.00 11.40 COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE CC5A/CD5AA060 56,000 TDR 12 12 10.85 CE3AA060,000 TDR 12.2 12.2 11.3 CK3BA060 56,000 TDR 12.2 12.2 11.05 060-A, B CK5A/CK5BA060 CK5A/CK5BT060 56,000 56,000 TDR TDR 12.2 12.2 12.2 12.2 11.05 11.05 CK5A/CK5BX060 58,000 TDR 12.5 12.5 11.45 COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AA060 56,000 TDR 12 12 10.85 CC5A/CD5AW060 58,000 TDR 12.5 12.5 11.2 CE3AA060,000 TDR 12.2 12.2 11.25 CK3BA060 56,000 TDR 12.2 12.2 11.05 CK5A/CK5BA060 56,000 TDR 12.2 12.2 11.05 CK5A/CK5BT060 56,000 TDR 12.2 12.2 11.05 CK5A/CK5BX060 58,000 TDR 12.5 12.5 11.45 COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AA060 56,000 TDR 12 12 10.95 CC5A/CD5AW060 58,000 TDR 12.5 12.5 11.25 CE3AA060,000 TDR 12.2 12.2 11.35 CK3BA060 56,000 TDR 12.2 12.2 11.1 CK5A/CK5BA060 56,000 TDR 12.2 12.2 11.1 CK5A/CK5BT060 56,000 TDR 12.2 12.2 11.1 CK5A/CK5BX060 58,000 TDR 12.5 12.5 11.5 * Tested Combination In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR. Must be installed with hard shutoff TXV to achieve rating. EER Energy Efficiency Ratio LSV Liquid Solenoid Valve SEER Seasonal Energy Efficiency Ratio NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 14

EVAPORATOR AIR CFM 525 600 5 EWB See notes on page 24. DETAILED COOLING CAPACITIES* CONDENSER ENTERING AIR TEMPERATURES F 85 95 105 115 125 Sens kw** Sens kw** Sens kw** Sens kw** Sens 563G018-A Outdoor Section With CC5A/CD5AA018 Section kw** 18.88 9.78 1.41 18. 9.80 1. 18.00 9.59 1.76 17.06 9.23 1.95 16.06 8.86 2.14 17.66 12.33 1.39 16.96 12.12 1.56 16.07 11.73 1. 15.16 11.36 1.89 14.15 10.95 2.08 15.89 14.52 1.38 15.13 14.13 1.52 14.32 13.70 1. 13.45 13.21 1.84 12.60 12.60 2.03 15.15 15.15 1.37 14.60 14.60 1.51 13.96 13.96 1.66 13.28 13.28 1.84 12.60 12.60 2.03 18.95 9.98 1.44 18.90 10.14 1.61 18.23 10.11 1.79 17.38 9.69 1.99 16.36 9.32 2.18 17.93 12.91 1.43 17.25 12.80 1.59 16.39 12.47 1.76 15.46 12.09 1.93 14.44 11.68 2.12 16.24 15.42 1.40 15.47 14.99 1.56 14.63 14.63 1.71 13.85 13.85 1.88 13.08 13.08 2.08 15.79 15.79 1.40 15.19 15.19 1.55 14.55 14.55 1.71 13.85 13.85 1.89 13.09 13.09 2.07 19.00 10.15 1.47 19.02 10.41 1.64 18. 10.46 1.82 17.69 10.18 2.02 16.59 9.76 2.23 18.13 13.45 1.45 17.49 13.59 1. 16.64 13.19 1.80 15.70 12.81 1.97 14.61 12.37 2.15 16.55 16.18 1.43 15.78 15.78 1.59 15.07 15.07 1.75 14.32 14.32 1.93 13.54 13.54 2.12 16.37 16.37 1.43 15. 15. 1.59 15.08 15.08 1.75 14.32 14.32 1.93 13.54 13.54 2.12 Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA 018 1.00 1.00 FK4(C,D)NF 001 1.05 0.88 024 1.04 1.01 002 1.06 0.88 CC5A/CD5AW 024 1.04 1.02 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CE3AA 024 1.04 1.01 CC5A/CD5AA 018 1.00 0.90 CF5AA 024 1.04 1.01 024 1.04 0.91 CK3BA 024 1.04 1.00 CC5A/CD5AW 024 1.04 0.91 CK5A/CK5BA 018 1.00 0.98 CE3AA 024 1.04 0.91 024 1.04 1.00 CK3BA 024 1.04 0.89 CK5A/CK5BW 024 1.04 1.00 CK5A/CK5BA 018 1.00 0.88 F(A,B)4(A,B)N(F,C) 018 1.00 0.98 024 1.04 0.90 024 1.04 0.99 CK5A/CK5BW 024 1.04 0.89 FC4(B,C)NF 024 1.04 0.97 COILS + 355MAV042060 VARIABLE-SPEED FURNACE FF1DNA 018 1.00 0.95 CC5A/CD5AW 024 1.04 0.92 024 1.04 1.00 CE3AA 024 1.04 0.92 FF1DNE 018 1.00 0.95 CK5A/CK5BW 024 1.04 0.91 024 1.04 0.99 COILS + 355MAV042080 VARIABLE-SPEED FURNACE FG3AAA 024 1.04 1.02 CC5A/CD5AW 024 1.04 0.92 CE3AA 024 1.04 0.92 15

EVAPORATOR AIR CFM 700 800 900 EWB See notes on page 24. DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES F 85 95 105 115 125 Sens kw** Sens kw** Sens kw** Sens kw** Sens 25.9 23.6 21.4 20.3 26.5 24.1 21.9 21.1 26.9 24.5 22.3 21.8 563G024-A Outdoor Section With CC5A/CD5AA024 Section 12.7 15.9 19.0 20.3 13.2 16.9 20.3 21.1 13.8 17.8 21.4 21.8 1.92 1.93 1.93 1.92 1.96 1.96 1.96 1.97 2.00 2.00 2.00 2.00 25.0 22.7 20.6 19.7 25.5 23.2 21.1 20.5 25.8 23.5 21.4 21.1 12.3 15.5 18.6 19.7 12.9 16.5 19.9 20.5 13.4 17.4 20.9 21.1 2.13 2.13 2.13 2.12 2.17 2.17 2.17 2.17 2.20 2.20 2.20 2.20 Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA 024 1.00 1.00 CC5A/CD5AW 024 1.01 0.91 030 1.02 1.02 030 1.02 0.91 CC5A/CD5AW 024 1.00 1.00 CE3AA 024 1.01 0.91 030 1.02 1.02 030 1.02 0.90 CE3AA 024 1.02 1.01 CK3BA 024 1.01 0.90 030 1.03 1.01 030 1.02 0.91 CF5AA 024 1.02 1.02 CK5A/CK5BA 024 1.01 0.90 CK3BA 024 1.00 0.99 030 1.02 0.91 030 1.02 1.01 CK5A/CK5BW 024 1.01 0.90 CK5A/CK5BA 024 1.00 0.99 030 1.02 0.91 030 1.02 1.01 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CK5A/CK5BW 024 1.00 0.99 CC5A/CD5AW 024 1.01 0.94 030 1.02 1.01 030 1.02 0.93 F(A,B)4(A,B)N(F,C) 024 1.01 0.99 CE3AA 024 1.01 0.93 030 1.03 0.99 030 1.02 0.92 FC4(B,C)NF 024 1.01 0.99 CK3BA 024 1.01 0.92 030 1.03 0.99 030 1.02 0.93 FF1DNA 024 1.01 1.01 CK5A/CK5BW 024 1.01 0.92 030 1.02 1.00 030 1.02 0.93 FF1DNE 024 1.01 1.01 COILS + 355MAV042080 VARIABLE-SPEED FURNACE 030 1.02 1.01 CC5A/CD5AW 024 1.01 0.92 FG3AAA 024 1.00 1.01 030 1.02 0.92 FK4(C,D)NF 001 1.03 0.91 CE3AA 024 1.01 0.92 002 1.03 0.90 030 1.02 0.91 003 1.03 0.89 CK3BA 024 1.01 0.90 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE 030 1.02 0.91 CC5A/CD5AA 024 1.01 0.91 CK5A/CK5BW 024 1.01 0.90 030 1.02 0.91 030 1.02 0.91 24.1 21.9 19.8 19.1 24.5 22.3 20.2 19.8 24.8 22.6 20.6 20.5 12.0 15.2 18.2 19.1 12.5 16.1 19.4 19.8 13.0 17.0 20.4 20.5 2.37 2.36 2.36 2.35 2.40 2.40 2.40 2.41 2.44 2.44 2.44 2.43 23.1 21.0 19.0 18.5 23.5 21.4 19.4 19.2 23.8 21.7 19.8 19.8 11.6 14.8 17.8 18.5 12.2 15.8 19.0 19.2 12.7 16.6 19.8 19.8 2.63 2.63 2. 2.63 2. 2. 2.66 2.66 2.71 2.71 2.70 2.70 22.2 20.1 18.2 17.8 22.5 20.5 18.6 18.5 22.8 20.7 19.1 19.1 11.3 14.5 17.4 17.8 11.8 15.4 18.5 18.5 12.3 16.3 19.1 19.1 kw** 2.94 2.93 2.92 2.94 2.98 2.97 2.96 2.98 3.02 3.01 3.00 3.03 16

EVAPORATOR AIR CFM 875 1000 1125 EWB See notes on page 24. DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES F 85 95 105 115 125 Sens kw** Sens kw** Sens kw** Sens kw** Sens 32.3 29.5 26.9 25.5 32.9 30.1 27.4 26.5 33.4 30.6 27.9 27.3 563G030-A Outdoor Section With CC5A/CD5AA030 Section 15.8 19.8 23.8 25.5 16.4 21.0 25.3 26.5 17.1 22.1 26.7 27.3 2.41 2.39 2.37 2.36 2.46 2.44 2.42 2.42 2.51 2.49 2.47 2.47 31.2 28.5 25.9 24.7 31.7 29.0 26.4 25.6 32.2 29.4 26.8 26.4 15.4 19.4 23.3 24.7 16.0 20.5 24.8 25.6 16.6 21.7 26.1 26.4 2.65 2. 2.61 2.60 2.70 2. 2.66 2.65 2.75 2.73 2.71 2.70 Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA 030 1.00 1.00 CK5A/CK5BA 030 1.00 0.92 036 1.02 1.00 036 1.02 0.90 CC5A/CD5AW 030 1.00 1.00 CK5A/CK5BW 030 1.00 0.92 CD5AW 036 1.02 1.00 036 1.02 0.90 CE3AA 030 1.00 1.00 COILS + 355MAV042040 VARIABLE-SPEED FURNACE 036 1.02 1.00 CC5A/CD5AA 030 1.00 0.96 CF5AA 036 1.02 1.00 036 1.02 0.95 CK3BA 030 1.00 1.00 CC5A/CD5AW 030 1.00 0.96 036 1.02 1.00 CD5AW 036 1.02 0.95 CK5A/CK5BA 030 1.00 1.00 CK3BA 030 1.00 0.97 036 1.02 1.00 036 1.02 0.95 CK5A/CK5BN 036 0.95 1.00 CK5A/CK5BW 030 1.00 0.97 CK5A/CK5BW 030 1.00 1.00 036 1.02 0.95 036 1.02 1.00 COILS + 355MAV042060 VARIABLE-SPEED FURNACE F(A,B)4(A,B)N(F,C) 030 1.01 0.99 CC5A/CD5AA 030 1.00 0.96 036 1.02 1.01 036 1.02 0.95 FC4(B,C)NF 030 1.01 0.99 CC5A/CD5AW 030 1.00 0.96 033 1.03 0.99 CD5AW 036 1.02 0.95 036 1.02 1.01 CK3BA 030 1.00 0.96 FF1DNA 030 1.00 1.00 036 1.02 0.95 FG3AAA 036 1.02 1.00 CK5A/CK5BA 036 1.02 0.95 FK4(C,D)NF 001 1.01 0.93 CK5A/CK5BW 030 1.00 0.96 002 1.01 0.93 COILS + 355MAV042080 VARIABLE-SPEED FURNACE 003 1.03 0.91 CC5A/CD5AA 030 1.00 0.96 005 1.03 0.90 036 1.02 0.95 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AW 030 1.00 0.96 CC5A/CD5AA 030 1.00 0.93 CD5AW 036 1.02 0.95 036 1.02 0.92 CK3BA 030 1.00 0.96 CC5A/CD5AW 030 1.00 0.93 036 1.02 0.94 CE3AA 030 1.00 0.92 CK5A/CK5BW 030 1.00 0.96 CE3AA 036 1.02 0.93 036 1.02 0.94 CK3BA 030 1.00 0.93 COILS + 355MAV060080 VARIABLE-SPEED FURNACE 036 1.02 0.92 CK3BA 030 1.00 0.97 CK5A/CK5BA 030 1.00 0.93 036 1.02 0.95 036 1.02 0.92 CK5A/CK5BW 030 1.00 0.97 CK5A/CK5BT 036 1.02 0.92 036 1.02 0.95 CK5A/CK5BW 030 1.00 0.93 COILS + 355MAV060100 VARIABLE-SPEED FURNACE COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CK3BA 030 1.00 0.94 CC5A/CD5AA 030 1.00 0.92 036 1.02 0.93 036 1.02 0.91 CK5A/CK5BW 030 1.00 0.94 CC5A/CD5AW 030 1.00 0.92 036 1.02 0.93 036 1.02 0.91 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CE3AA 030 1.00 0.91 CK3BA 030 1.00 0.95 036 1.02 0.92 036 1.02 0.93 CK3BA 030 1.00 0.92 CK5A/CK5BW 036 1.02 0.93 036 1.02 0.90 30.0 27.4 24.9 23.9 30.5 27.9 25.3 24.8 30.9 28.2 25.8 25.6 14.9 18.9 22.8 23.9 15.6 20.1 24.2 24.8 16.2 21.2 25.4 25.6 17 2.91 2.88 2.87 2.86 2.96 2.94 2.91 2.91 3.01 2.99 2.96 2.96 28.8 26.2 23.8 23.1 29.2 26.7 24.3 24.0 29.6 27.0 24.7 24.7 14.5 18.5 22.3 23.1 15.1 19.6 23.6 24.0 15.7 20.7 24.7 24.7 3.21 3.18 3.15 3.16 3.26 3.23 3.18 3.21 3.31 3.28 3.26 3.26 27.5 25.1 22.8 22.3 28.0 25.5 23.3 23.1 28.3 25.7 23.8 23.8 14.0 18.0 21.7 22.3 14.6 19.1 23.0 23.1 15.2 20.2 23.8 23.8 kw** 3.54 3.52 3.47 3.50 3.59 3. 3.55 3.55 3.65 3.58 3.58 3.60