FROM COMPONENTS TO SYSTEM APPROACH OPTIMIZATION OF AIR-WATER HEAT PUMPS

Similar documents
1 Title of presentation Enter First name, surname Date

Optimized fan system design for the one-year cycle of a Heat Pump. Ziehl-Abegg SE Frieder Lörcher

Movement by Perfection. The Royal League in ventilation, control and drive technology. Fans for agriculture. Durable, efficient, well designed

Movement by Perfection. The Royal League in ventilation, control and drive technology. ZAvblue Increased air flow at smaller diameter

ECblue highefficiency

LOWERING THE COST OF HIGH CEILINGS

Swiss Heat Pump Research Highlights II Advanced Heat Pumps in Switzerland Prof. Dr. Beat Wellig

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Understanding Fan System Effects

Rotodynamic Pumps INTRODUCTION:

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

Fans: Features and Analysis

Tunnel Systems. Design & Supply Metro Axial Fans. Tunnel Axial Fans. Jet Fans.Fans for Escape Tunnel System Components. Engineering Support

Development of the San Ace Airflow Tester - A Measuring Device for System Impedance and Operating Airflow of Equipment

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Fan Selection. and Energy Savings

STANDARD, QUIET AND SUPER QUIET THE MODELLING OF FLOW AND THE REDUCTION OF TURBULENCES

GFD. GVD V-shape coil condenser. Güntner Info. 8 additional basic models for container transport!w. V-shape coil drycooler

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

FlowGrid for Axial and Centrifugal Fans

Water engineers and utilities are often

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

Axial fans The right fan for every house

Introduction to Fans. The Basics of Fan Principles and Terminology

Efficient Motor Technology for the Home Appliance Industry

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

Air flow management tutorial session. ACC Users Group 8 th Annual Conference Dallas, 4 October 2016 Sander Venema Howden Netherlands

What is the correct type of fan: Axial, radial, diagonal?

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

EC, energy efficient building services

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products

Howden Netherlands Cooling Fans. Desmond de Haan Area Manager

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

EC Plug Fans EC FanGrid Retrofits for High Efficiency Air Handling Units

Selecting Fans and Determining Airflow for Grain Drying and Storage

FLOW AND PERFORMANCE INVESTIGATIONS OF CENTRIFUGAL BLOWERS WITH AEROFOIL BLADED IMPELLERS

ErP. ErP READY. The Eco-Design Directive ErP for refrigerator systems and heat pumps. READY

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Küba SF blastfreezer. High-performance air cooler for blast chilling and shock freezing

Stock Vessels for Improved Quality and Energy Savings

Fan System for Drop Ceilings

HasconWing. Fixed or variable airfoil profile axial impellers

Safely Using a Centrifuge Near a Biological Safety Cabinet in Your Cell Culture Laboratory

Multifunction pump for handling gaseous liquids in process engineering

Effects of Volute Tongue Clearance and Rotational Speed on Performance of Centrifugal Blower Nitin S. Jadhav *, S. R. Patil

Effect of Flow Distortion in Inlet Duct on the Performance of Centrifugal Blower

POWERPLUS SPP Product Brochure

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan

EXPERIMENTAL ACOUSTIC CHARACTERIZATION OF A WET VACUUM CLEANER

FlowGrid for Axial and Centrifugal Fans

Performance Analysis of Centrifugal Fan by CFD

Design And Analysis Of Centrifugal Pump

GAS CONDENSING TECHNOLOGY

Fan Array Systems WHITE PAPER. Rad Ganesh, PhD, P.E. Director, R&D / Applications Twin City Fan Companies, Ltd. Minneapolis, MN, United States

Signs + or - The desired duty point lies for fans with preceding + sign, outside its optimum using area. It is recommended to use a bigger fan size.

ICSV14. Cairns Australia 9-12 July, Noise reduction of handheld vacuum cleaners according to geometric optimization of air passages

FlowGrid air-inlet grille for axial and centrifugal fans. Less noise more quality of life.

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

Myth & Reality of Basement Ventilation

Mobile Heating System K e - for high comfort and remote control. HEYLO All Rights Reserved. EXPERT FOR PROFESSIONALS

Car Park Ventilation 1

DAE Systems. Fan Selection Guide. Section 1: Terminology

Vacuum - The Universal Conveying Force Suction and transportation of powders, liquids and gases

Agitation and Mixing

FAN ENGINEERING. Surge, Stall and Instabilities in Fans

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Operating instructions

How to improve air cooler vacuum steam condensers performance in the field

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

How to ensure Thermal Comfort in buildings with CFD

Agenda and Objectives

High-efficiency Turbo Chiller (NART Series)

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

Specially Designed Waste Water & Sewage Pumps

A Novel Approach for the Thermal Management. of PC Power Supply

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

HEATING & COOLING COIL PRODUCTS

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

FlowGrid for Axial and Centrifugal Fans

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

ARI 260 Standard: Sound Rating of Ducted Air Moving and Conditioning Equipment

PRODUCT CATALOG.

ISO AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY

ECV SP GUE ALO CAT ICAL TECHN

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

Product Data Sheet 4114 N/17HH-218. The engineer's choice

Low-noise fans are not a product of chance

Selecting the Correct Fan

iq Star by Fläkt Woods Multi-service Chilled Beam Guide Star by Fläkt Woods

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

CVGF. Water Cooled Centrifugal Chillers

Chapter 4 Compressors Overview & System Annual Power Consumption

Indirect Gas-Fired Make-Up Air

LOW-NOX BURNER RETROFIT CHALLENGE

Cooling Solutions for High Heat Flux in Dense Packed Servers. Dr. Walter Angelis R&D Manager Aerodynamics Helmut Sebisch Key Account Manager

Blow through unit coolers LEX. Standard coolers for cooling & freezing rooms

Transcription:

- 1 - FROM COMPONENTS TO SYSTEM APPROACH OPTIMIZATION OF AIR-WATER HEAT PUMPS Joachim Dietle, Dipl.Ing.(FH), Product Manager Axial Fans; Ziehl-Abegg SE Heinz-Ziehl-Strasse, 74653 Kuenzelsau, Germany Abstract: Air-water heat pumps are currently the most frequently used heat pumps in Europe. This is due to the easy connection of the heat pump to its heat source ambient air. Complex drill holes or collector systems are not necessary. However, adverse effects are low efficiency and higher noise levels. The presentation shows how the air flow within a heat pump can be optimized. The objective is to transport ambient air to the evaporator with as low energy demand as possible. This will be achieved by using air direction elements such as guide vanes or diffuser, which convert dynamic pressures into static pressures. These air direction elements have, however, one important disadvantage: They need space which is normally not given in heat pumps. The new construction will be demonstrated. It combines all the advantages with minimal needed space. The development of is based on extensive CFD-calculations. For optimal implementation of the geometry, high-performance composite material is used. On the basis of different comparative measurements, impressive advantages in the field of efficiency and acoustics in comparison to conventional solutions will be shown. Key Words: heat pump, efficiency, noise, fan,, optimization, pressure 1 INTRODUCTION Efficiency or COP of air source heat pumps depend of many factors, following we will focus on the air side and show remarkable improvements. The required air flow through the evaporator must be efficient as possible. Figure 1: Air side of air source heat pump Following basic formula for calculation the power demand of a fan indicate how to optimize the system. P Fan = q v x (p stat + p dyn ) /η Fan (1) P Fan power demand of fan q v air volume flow p stat static pressure drop p dyn dynamic pressure drop η Fan total efficiency of fan

- 2 - To have a minimum in power demand, we have to achieve following points: High efficiency of fan Minimal air volume flow Minimal static pressure Minimal dynamic pressure High efficiency of fan The optimization of components, in this case of the fan, is a first approach to improve a heat pump. Notable improvements in efficiency and acoustics could be reached during the last years. However, one component is only one part in the entire system. Optimized fine-tuning of the individual components will be the next step. Minimal air volume flow The air flow volume determines the energy input on the heat pump and therefore has to be controlled properly. Speed controlled fans are used here. In heat pumps, EC motors have been used most commonly during the last years. Reasons for using EC fans are their high efficiency, even for reduced speed, as well as their integrated speed controller. The required airflow can be adjusted easily and efficiently to the needed heating performance. Minimal static pressure The airside pressure drop of a heat pump is mainly determined by the heat exchanger. It is to be noted that as a result of condensation and icing up of the heat exchanger an additional pressure drop can occur. This effect however can clearly be influenced by a better design of the heat exchanger. Due to less icing up and optimal defrosting methods, the seasonal performance factor can be improved. However, there is room for substantial improvements of air flow. These and more improvements were shown in the study of Hochschule Luzern, see references. In the following, an optimal nozzle/ housing for axial fans will be presented. 2 OPTIMIZATION OF AIR FLOW Fans respond sensitively to interferences in inflow. That is why turbulences in front of the impeller are to be avoided. Especially turbulences in the working area of the impeller can lead to disruption in air performance, efficiency and acoustics. Air flow in axial fans can be divided into axial, centrifugal and circulating flow parts. There is a lot of useless dynamic that can be optimized. Figure 2: CFD - VISUALIZATION OF AIR FLOW

- 3 - This situation has been known for a long time. Therefore different flow optimizing components are used. Inflow nozzle Inflow nozzles lead to an optimal turbulence-free airflow of the impeller. The geometry is basically dependent on the flow speed and the upstream suction chamber. As mentioned before, turbulences are to be avoided and a homogeneous air velocity over cross flow section of the heat exchanger is to be ensured. Guide vanes Guide vanes guide circulating flow components. The objectives are on the one hand to achieve an optimal airflow of subsequent impellers (e.g. turbines) and on the other hand to reach an axial flow and a reduction of air velocity to change dynamic to static pressures. That is exactly the approach that is using. Diffusers Diffusers expand the cross-sectional area and reduce the flow speed. Therefore the pressure is changed from dynamic to static pressure. In the following, will be presented. 3 THE BEST WAY TO OPERATE AN AXIAL FAN Traditionally short bell mouths are competitive parts of housings of a fan operated devices. Due to material and production processes the constructive possibilities are limited, so the aerodynamic performance is poor. Today state of the art is a full bell mouth, here the complete impeller is working inside the nozzle. This is on time and material basis more complex and more expensive. Both solutions need additional support for the fan. A finger protection is often included within the support. short bell moth full bell mouth Figure 3: Nozzles for axial fans improves the air flow situation by a new CFD-based design of nozzle, diffuser and suspension as guide vane. The development focused on reaching best efficiency using minimal space. A combination of all described flow improving components must be used to be constructive. The construction is only possible when using high performance composite material. In addition to effective degrees of freedom in design, the material offers high chemical resistance and a reduction in weight. In the following, the airflow improvements will be presented.

- 4-4 BENEFITS OF Based on comparisons carried out with the ZIEHL-ABEGG selection program FANselect (www.fanselect.info), we will show the improvement by using against a poor short bell mouth and a state of the art full bell mouth. All these data were determined on measurements made in our R&D-center InVent, where the largest combined air performance and sound test rig for fans is located. The characteristic air performance curves are measured in compliance with DIN EN ISO 5801 and AMCA 210-99 with free intake and free blow out (installation type A). The measurements are TÜV and AMCA certified. The following diagrams include first the complete performance of a FE2owlet axial fan size 500 mm with ECblue drive size EC116 on 1440 rpm. Here the pure aerodynamic improvement over the complete operation area was visualized. Additionally the real comparable improvement by going to the duty point of 6.000 m³/h air volume flow and a static pressure drop of 100 Pa were presented. This duty point is shown as a star in the following diagram. Here the fan is running in different speeds, depending on the built-in situation, short bell mouth, full bell mouth and the system. First shown on European Heat Pump Summit 2013. Improve air power Figure 4: improve air flow Over the complete operating range the airflow is improved. The improvement depends on the originally used system and on the duty point. Higher pressure leads to more circulating flow components. In customer measurements, we often found more than 10% of more air flow. This improvement can be used to downscale the device or to increase the heating power. But in addition to the airflow, also offers a higher pressure reserve, which is necessary for safe operation. That is important for icing conditions or when the heat pump is located inside a house and a ducting is required.

- 5 - Improving efficiency change useless dynamic pressure into required static pressure. In doing so, the fan is unloaded and the efficiency will rise. Coming from a short bell mouth the power demand of the duty point in is 215 W less, which is a reduction by 34%. The reduction compared with a full bell mouth is -142 W or 25%. That massive improvement makes inefficient fans with AC-motors compliant to ErP2015 (European directive for minimum efficiency of fans). total system efficiency static system efficiency Figure 5: improve efficiency Improve sound power Easily spoken, reducing air velocity means reducing turbulences which will decrease the sound power of the heat pump. Although offers more airflow it is at the same times more silent than using a full bell mouth and even using a short bell mouth. In and equal duty point we measured a reduction of 6 db(a) coming from a short bell mouth and 4 db(a) compared to the full bell mouth. Figure 6: reduce sound power

- 6-5 CONCLUSION Air source heat pumps can be easily improved by using modern innovative fan systems like. The optimization can be used to get more heating capacity or to reduce power demand and therefore increase the COP of the heat pump. Additionally a noise reduction will occur. 6 REFERENCES Lukas Gasser, dipl. Ing. FH, Ivan Wyssen, BSc Maschinentechnik, Maik Albert, dipl. Ing. FH, Marc Häusermann, BSc Maschinentechnik, Mirko Kleingries, Dr.-Ing., Beat Wellig, Prof. Dr. sc. techn. ETH Hochschule Luzern HSLU T&A, December 2011, Effiziente Luft/Wasserwärmepumpen durch kontinuierliche Leistungsregelung Lukas Gasser, dipl. Ing. FH, Beat Wellig, Prof., Dr. sc. Techn. ETH Hochschule Luzern, Effiziente Heizsysteme mit leistungsgeregelten Luft/Wasserwärmepumpen, 18. Tagung des BFE-Forschungsprogramms «Wärmepumpen und Kälte» 27. Juni 2012, HTI Burgdorf Joachim Dietle Dipl.Ing.(FH) Ziehl-Abegg SE, From components to system approach Optimization of air-water heat pumps, European Heat Pump Summit 2013 ZIEHL-ABEGG product documentation www.ziehl-abegg.com ZIEHL-ABEGG selection program FANselect www.fanselect.info