Annexure-I Purchase Table-1 (R.O. Water Purifier Units and Chiller Units)

Similar documents
Indian National Trust for Art and Cultural Heritage (INTACH, 71, KK Birla Lane, Lodhi Estate, New Delhi , Ph. No.

VOLUME 2 (BOQ & Price Bid)

TECHNICAL SPECIFICATION

3000 LPH MANUFACTURERS

OFFICE OF THE PRINCIPAL GOVERNMENT ENGINEERING COLLEGE JAGDALPUR (C.G.)494005

TENDER DOCUMENT. NIT No: DLI/C&E/WI-721/271 FOR

GUJARAT NARMADA VALLEY FERTILIZERS & CHEMICALS LTD MTA PAC PROJECT ANNEXURE 6.4 SECTION 10 SPECS FOR AIR CONDITIONING

VOLUME 3 (Technical Specifications as Annexure-A & Drawing)

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

Water Chiller Solutions. A solution to every water cooling need.

SMALL AIR COOLED CONDENSERS

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG.

.2 Section Waste Management and Disposal.

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

THERMAL ENGINEERING LABORATORY II. To train the students with principles and operation of thermal Engineering equipments.

COOLPLUS KENYA LIMITED. The "Only Manufacturer" of Uninterrupted Cold Stores & Trough Cooling Systems for post Harvest solution Recycling.

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

30GN FLOTRONIC II AIR-COOLED CHILLERS

SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD., CIRCLE OFFICE, BHOPAL PART B : PRICE BID

30GT FLOTRONIC AIR-COOLED CHILLERS

OACS Outdoor Air-Cooled Central Chillers

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

Call us today! (800)

Call us today! (800)

SCA 620C AIR COOLED SCREW CHILLER

500 EX Fusion Compressor Series

BILL OF QUANTITY OF AIR CONDITIONING WORK FOR SBI JASDAN BRANCH, RAJKOT

Vicot Air Conditioning Co., Ltd. CONTENT

TECHNICAL BID EVALUATION SCOPE OF WORK COMPRESSED AIR SYSTEM

BRINE CHILLER DESCRIPTION

VariCool VAV Engineering Guide

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

Evaporators 60HZ version

Call us today! (800)

Cool Your Self with. Dana Water Chillers COMPANY PROFILE. The Coolest One.

SARAVEL Minichill PACKAGED LIQUID CHILLERS

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

Economical and Energy Efficient Air Conditioner Using Calcium Liquid as a Secondary Refrigerant.

Innovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz)

INDUSTRIAL EXTENSION BUREAU

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz


Guide Specifications PART 1 GENERAL 1.01 SUMMARY

CENTRAL SPLIT UNIT UNIC

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

Tender document for Supply/ Installation of New Fire extinguishers & Refilling TENDER NOTICE

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

ACMVTECH HIGH EFFICIENCY UNITARY AHU

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Ref. No. RRSS/CH-18/ RIDF Dated : ii) Submission of e-tender: the tender shall be submitted on line within upto 6.00 pm.

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Vertical self-contained air conditioner

Concealed Ducted Split Series R-407C MBH

REFRIGERATED AIR DRYERS

Aquaflair TRAC-TRAF-TRAH

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

COLLEGE OF AGRICULTURE, NAGPUR

MAC N-407 Air-Cooled Chiller

DESIGN STANDARDS SECTION 15600

Walk in Steam Curing Chamber for Concrete Application. Detailed Working Specifications

SBI INFRA MANAGEMENT SOLUTIONS PVT.LTD. HEAD OFFICE-GROUND FLOOR RAHEJA CHAMBERS, FREE PRESS JOURNAL MARG, NARIMAN POINT, MUMBAI-21

Industrial cooling solutions

Precise Temperature Control; Compact Footprint

MACH N-407 Heat Pump Air-Cooled Chiller

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

TENDER CRFQ NO (E-TENDER REF NO.13020)

DRYTEC REFRIGERANT DRYERS

13 GEP A L P - 1 A

HEATING & COOLING COIL PRODUCTS

MEC SHOT. [An ISO 9001:2000 Certified Company] BLAST CLEANING & FINISHING SYSTEM

LOW STATIC HYDRONIC DUCTED UNIT

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

American Brand with Global Reach. Model: SMLW-SAGL

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

SECTION AIR COOLED WATER CHILLERS (LESS THAN 150 TONS)

Industrial Vacuum Cleaners & Dust Collection Equipment. Industrial Vacuum Cleaners

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

MAC-120HE-03 Air-Cooled Chiller

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

EHH SERIES DRAW THROUGH FAN COILS CFM

POOL HEATING. Making Heat something Cool

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

Transcription:

Rayat Shikshan Sanstha s Karmaveer Bhaurao Patil Mahavidyalaya, Pandharpur, Dist-Solapur - 4133304 Ph : 02186-223104 TENDER FORM Email : kbppandharpur@gmail.com Date : 12-08-2017 A] General Information: 1. Name of the Firm with Address : 2. Contact Nos. and Email : B] Tender Quote: Annexure-I Purchase Table-1 (R.O. Water Purifier Units and Chiller Units) RO System 2 m3/hr ( For 2000 liter/ hr.) I Dosing System 2 Dosing Pump Flow Lph 0-6 3 Pump Material PP 4 Pump Make E DOSE / positive 5 Dosing Tank Capacity Lit 100 6 Tank Material PP/HDPE 7 Tank make Sarita/Sintex outer shell SS II Micron Cartridge Filter 2 Flow m3/h 2.0 3 Filtration Rating μ 5 4 Filter Material HOUSING PP 5 Filter Size Inch 20 x 4 inch 6 Housing Material PVC III High Pressure Pump 2 Flow m3/h 2 3 Head M 120 4 Power Kw 1.5 5 Type Vertical/Centrifugal 6 MOC SS 304 7 Make CRI/NANFANG/ leo pumps

IV RO Unit 1 Membranes No 8 2 Membrane Dia Inch 4 3 Membrane Length Inch 40 4 Material TFC, Polyamide 5 Make HYDRAUN- AUTICS / DOW/ csm 6 RO Vessels No 2 7 Rating psi 300 8 Material FRP 9 Vessel Dia Inch 40 10 Vessel Length m 2000 mm 11 Make FABRICATED 12 Rating SCHEDULE 20 V Piping & Valve 1 Low Pressure Piping Cpvc 2 Make Prince / astral 3 Rating Schedule 40 4 High Pressure Piping pvc 5 Pipe moc upvc 6. Rating SCHEDULE 20 7. Fittings Seamless/T.C.connectors 8. Welding pasting VI Instruments on RO Systems 1 Pressure Gauge no 8 2 Guage type Waaree make back connection 3 Pressure guage range 0-25 kg/cm2 4 Pressure Switch High & no 2 NOS DANFOSS Low 5 Flow Indicators(Rotameter) no 4 ASTER 6 MOC Acralic 7 TDS Meter No 1 Cabling from panels to drive. VII Control Panel 1 MOC MS Powder Coated 2 Ace Electronic multifunctional energy meter 3 Accerories Ph Display TDS display 4 Make Siemens/L&T

RO System 1 m3/hr (For 1000 litre/hr.) I Dosing System 2 Dosing Pump Flow Lph 0-6 3 Pump Material PP 4 Pump Make E DOSE / positive 5 Dosing Tank Capacity Lit 100 6 Tank Material PP/HDPE 7 Tank make Sarita/Sintex outer shell SS II Micron Cartridge Filter 2 Flow m3/h 2.0 3 Filtration Rating μ 5 4 Filter Material HOUS- PP ING 5 Filter Size Inch 20 x 4 inch 6 Housing Material PVC III High Pressure Pump 2 Flow m3/h 2 3 Head M 120 4 Power Kw 1.5 5 Type Vertical/Centrifugal 6 MOC SS 304 7 Make CRI/NANFANG/leo pumps IV RO Unit 1 Membranes No 4 2 Membrane Dia Inch 4 3 Membrane Length Inch 40 4 Material TFC, Polyamide 5 Make HYDRAUNAUTICS / DOW/csm 6 RO Vessels No 2 7 Rating psi 300 8 Material FRP 9 Vessel Dia Inch 40 10 Vessel Length m 2000 mm 11 Make FABRICATED 12 Rating SCHEDULE 20 V Piping & Valve 1 Low Pressure Piping Cpvc 2 Make Prince / astral

3 Rating Schedule 40 4 High Pressure Piping pvc 5 Pipe moc upvc 6. Rating SCHEDULE 20 7. Fittings Seamless/T.C.connectors 8. Welding pasting VI Instruments on RO Systems 1 Pressure Gauge no 8 2 Guage type Waaree make back connection Pressure guage range 0-25 kg/cm2 Pressure Switch High & no 2 NOS DANFOSS Low Flow Indicators(Rotameter) no 4 ASTER MOC Acralic TDS Meter No 1 Cabling from Panels to drive VII Control Panel 1 MOC MS Powder Coated 2 Ace Electronic multifunctional energy meter 3 Accerories Ph Display TDS display 4 Make Siemens/L&T For Chilling Unit : I. 3 TR. Capacity S.NO. SPECIFICATION DETAILS 1 Model AC 300/OL 2 Refrigeration Compressor Capacity:2 TR Make: Emerson Copeland Type: Hermetically Sealed, Reciprocating 3 Heat Exchanger Plate Type Heat Exchanger 4 Condenser Make : MWTPL Size: 24 x 24 4 row Type: Copper Tubes & Aluminum Fins 5 Fan & Motor Make: GE/ Hicool Size: 18, axial fan, Suction 7 Inlet & out let connections 3/4 BSP 8 Refrigerant R 22 9 Voltage 440 V/ 3 PH/ 50 Hz OR 230 V AC 10 Noise Level 70 DB 11 Weight 120 Kgm 12 Dimensions 40 (W)X 40 (L)X 30 (H)

II. For 5 TR Capacity : S.NO. SPECIFICATION DETAILS 1 Model AC 500/OL 2 Refrigeration Compressor Capacity:5 TR Make: Emerson Copeland Type: Hermetically Sealed, Reciprocating 3 Heat Exchanger Plate Type Heat Exchanger 4 Condenser Make : ANNAIR Size: 26 x 18 6 row Type: Copper Tubes & Aluminum Fins 5 Fan & Motor Make: GE/ Hicool Size: 20, axial fan, Suction 7 Inlet & out let connections 1 BSP 8 Refrigerant R 22 9 Voltage 440 V/ 3 PH/ 50 Hz OR 230 V AC 10 Noise Level 70 DB 11 Weight 120 Kgm 12 Dimensions 30 (W)X 30 (L)X 40 (H) TERMS & CONDITIONS Sealed tenders are invited in Price bid by the undersigned authorized distributors for the purchase of following item(s) as per specification given above in Annexure-I through registered Post/Courier or these can be submit personally in the office upto 19-08-2017 SIGNATURE OF THE TENDERER WITH STAMP