Descaler & Prevention

Similar documents
Volume 10 Summer Understanding Terminology Key to Treatment Program Success

Watch Water USA Green Chemical Technology

CEHA Fall Chloride Workshop. Chloride Treatment Options Presented by Paul Hurlbut Professional Water Systems, Inc.

INTAC PARTS & SERVICES ( H)

HAVABLACK S2G BLACK OXIDE SALTS FOR IRON & STEEL

Akiki Engineering Est.

Residential Application

The Electronic Anti-Scale System Condominiums and Large Buildings

If your soil has a high salinity content, the plants

Evaporative Cooling products

10 Quickbreak. Cleaning & Maintenance Products

Which RO/DI Water Heater is Right For Your Application? By: Caitlin Carrier

FERN MULTIPLICATION KIT

AC40 & AC40BAutomatic Water Softener Operation and Recharging

ACIDS & ACID CLEANERS

Installation, Operation and Maintenance Manual

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles.

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

Akiki Engineering Est.

PUROTAP easy. Installation Function Operation Service. fast efficient safe. Demineralised heating water perfect for every system

Industrial Descale Solutions & Descale Services

AQUACALK EQUIPMENT. Description of the problem:

PIPING APPLICATION GUIDE

The Alfa Laval. Cleaning procedures. for. HeatExchangers.

Laboratory Glassware Cleaning and Storage

Description. Main components. Lifting eyes To used for lifting and transport securing. Carrying bar Carries the cassettes and the pressure plate.

AC39 Manual Water Softener Operation and Recharging

Scale Stopper Plus Installation & Start-Up Guide

Installation, Operation and Maintenance Manual

TEMPLATE ASSISTED CRYSTALLIZATION. Presented By Ryan Lessing 11/13/2014

Soil. Acidic soils... 1/19/2014

BOILER SYSTEM CHEMICAL TREATMENT 101

CASE STUDY PLASTIC INJECTION MOLD CLEANING

Technical Specifications & Pricing

Innovative Cleaning Technology

The Solution to Your Marine-Based Water-Scale Problems! RYDLYME Marine

TERRESTRIAL ORCHID SEED SOWING KIT

HydroBlend TM Water Treatment Product Characteristics

WELCOME TO THE AWT REGIONAL TRAINING PROGRAM

Case Study and 700 HP Steam Boilers - Scale

Instruction and Maintenance Manual. Spiral Heat Exchanger

CLEANING. Application Recommendations. Application/ Concerns. Articles Cleaned/ Soil Removed. Recommended Detergent. Cleaning Method.

Protective Chemistry for Steam Boiler Wet Layup posted to DPS client area on:

Z86 Safety-Plus Industrial Cleaner Concentrate

Carry Out Maintenance Procedures

Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment

Chanson Water USA, INC. Installation Guide for SCF-3000/SCF-6000

PARTS CLEANING AND DEGREASING

Anorganic Fertilizer. Lenny Sri Nopriani, SP.MP

Pretreatment Processes for the Aluminum Extrusion Industry. Harry Adams - BCI Surface Technologies Bruce Chambeau Republic Chemical Co., Inc.

READ AND SAVE THESE INSTRUCTIONS DE-SCALING SOLUTION. Humidifier De-scaling Solution and Neutralizer. Usage Instructions

Instruction Manual Plate Condenser. AlfaCond 400/600/800. Part number

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

AFRICAN VIOLET MULTIPLICATION KIT

Channel plates Heat is transferred from one medium to the other through the thin channel plates.

Pipe: ASTM B88, hard drawn copper, Type K. Fittings: ASTM B16.22 Wrought copper and copper alloy.

From Drops to Powder From a Suspension to a Granulate. Innovative Processing of Fluids in Fluidised Bed Dryers

APPLICATION NOTE NO. 2D Revised October Instructions for Care and Cleaning of Conductivity Cells

Application Data Sheet

Mixing Training Course P/N Rev. D

Commercial dishwashing & cleaning agents

Cavitator Ultrasonic Cleaner Instruction Manual

Global Soils. The Nature of Soil The Soil Water Balance Soil Development The Global Scope of Soils Global Climate Change and Agriculture

Installation & Operation Manual Models:

smardy - pure water Reverse osmosis system YR100-A 75 GPD

SB Series Brazed Plate Heat Exchanger Installation Manual

Digital Salt / TDS Meter. 390a. The Value Leader TM

Installation, Operation and Maintenance Manual

AQUABION Galvanic water treatment for limescale & corrosion Frequently Asked Questions (FAQ s) June 2018

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

Water Quality in Hydronic Systems March 10, Q&A Documentation

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

Cavitator Ultrasonic Cleaners

Water Quality in Hydronic Systems April 16, 2015 with Guest Speaker Jim Poehling, P.E., LEED AP Q&A Documentation

ProMoss TM Plant-Based Water Treatment Solves Problems in Tobacco Manufacturing Plant Air Washer Systems

Boiler Additives And Filtration

CHAPTER 18 EVAPORATION AND FREEZING

MRO CHEMICALS CLEANERS & DEGREASERS

NOBURST. NOBURST Antifreeze & Heat Transfer Fluid Factory Pre-mixed Freeze Protection for Water-based Heating and Cooling Systems

Institutional Catalogue

For inspection purposes only.

D Dissolution Units Mixing Training Course P/N Rev. C

Care and Maintenance For EcoGranit sinks

9.0 Systems For Domestic Water Installations

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 7 Extinguisher Types Revised

WHITE PAPER The Importance of Rinsing in Metal Finishing Operations

SuperStor Ultra Stainless Steel Storage Tank

With the advancement of perennial production,

SPRAY AIDE COMPATIBILITY-ACIDIFIER-SURFACTANT AGENT PRINCIPAL FUNCTIONING AGENT:

INSTALLATION INSTRUCTIONS

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

Pesticide Applicator Equipment Cleaning to Prevent Carryover. Chuck Schuster University of Maryland Extension

RFP# FS REGION 8 TIPS FOOD PURCHASING CO-OP SANITATION AND CLEANING SUPPLIES FOR FOOD SERVICE AREA ONLY. Drop Ship 1 location 50 CT

BASIC BOILERS NAME :- DATE :-

Desiccants & Driers. By Norm Christopherson

Safety Lab Goggles are required! Apron is optional!

IDL / De Longhi Appliances via Seitz, Treviso Italia

7800 Neutralizer Installation & Start-Up Guide

INSTALLATION and OPERATION MANUAL DIRECT STEAM KETTLES MOUNTED ON ELECTRIC BOILER BASE CABINET MODELS: EMT-6 EMT-10 EMT-12 EMT-6-6 EMT-10-6 EMT-10-10

Transcription:

Descaler & Prevention Treatment Method for existing scaled surfaces like inside of piping, tubes, Heaters, boilers, sump wall etc. By Deepak Chopra Watch Water GmbH Fahrlachstraße 14 68165 Mannheim Germany Web: email: www.watchwater.de info@watchwater.de Telefon: +49 (0) 621 87951-0 Telefax: +49 (0) 621 87951-99 July 2013 1

WATCH Water Treatment Solutions An Introduction To Chemical Cleaning of Industrial Water Systems 2

WATCH Water Treatment Solutions Description: I-SOFT softens the Scale and the Wetting agent enhances the action of the green acid in removing deposits on surfaces action cleaning properties. The red color indicator provides an optical control for the determining whether the strength of the I-SOFT DESCALER solution is adequate for effective and efficient cleaning. 3

Reason for Cleaning Reason For Cleaning: Maintenance of an effective water treatment system is essential to minimize scale and corrosion problems in all industrial systems; however, scale and many other deposits that is already formed will require REMEDIAL CLEANING (descaling). If not removed, these scale and built up deposits will impact the safety of operation personnel, interfere with heat transfer and could cause excessive damage and destruction of the equipments and systems. 4

Types of Deposits Types of DEPOSITS: The deposits that occur in water systems are mostly inorganic mineral salts and corrosion products. Deposits composition range from very dense crystallite structures to very porous and loosely bound materials to gelatinous slimes. Almost all of the deposits formed from water constituents consist of corrosion products such as chlorides, sulfates, iron and copper oxides, mineral scales or mixture of these materials. The Deposits those are most hard to clean are silicates, sulfates, phosphates and these deposits could be spongy, porous or relatively hard and glass-like. 5

Remedial Cleaning REMEDIAL CLEANING (Descaling) Cleaning procedure with I-SOFT DESCALER is a Green Technology and performs very effective cleaning. I-SOFT DESCALER has largly replaced HCl and H 2 SO 4 cleaning process. The selection of I-SOFT DESCALER is the best choice because of its ability to remove or dissolve all kinds of deposits. It s the most cost effective solution and very safe to handle compared to the effect of cleaning on any metals involved. I-SOFT DESCALER contains a very special inhibitor that prevents from attacking the base metals while allowing the cleaning process to remove hard scale mixed with anti corrosion products. 6

I-SOFT DESCALER (ISD) I-SOFT DESCALER (ISD) is an odorless, pink INSTANT crystalline solid powder that can be easily dissolved in water. This dry INSTANT powder is known as (Scale Removing Compound). A 5% to 20% solution (2 to 8 kilograms) in approximately 40 liters water [4.4 to 17.6 pounds to approximately 10 gallons of of water] is used for removing hard scale from metal surfaces. All carbonate deposits are easily removed with ISD. Heating the circulation to a temperature in the range of 50 C - 70 C (122 F 158 F) can fasten the process. ISD is more effective on sulfate scales than any other acid like Hydrochloric acid. 7

I-SOFT DESCALER (ISD) Inhibited ISD, used at temperatures up to 50 C (122 F), will not corrode galvanized steel. It s used and highly recommended for removing scale in Cooling Towers Evaporative Condensers Pipe lines Commercial buildings Low pressure Boilers High pressure Boilers Heat Exchangers Residential systems And the biggest advantage ISD can be applied to any equipment while it is operating but should be drained from the system after few hours. I-SOFT DESCALER is the safest and fastest way to clean and de-scale. 8

Methods of Removing Scale Removing scale may be accomplished by circulating the inhibited ISD solution through the equipments or by soaking the equipment in a tank of diluted ISD. HOT RECIRCULATING INHIBITED ISD 1. Fill the equipment or any system (small or big system) coffee machine or power plant boiler with preheated near 50 C - 70 C (122 F - 158 F) with dilute ISD solution. 2. Allow the dilute ISD solution to remain in system for 1 to 10 hours, depending on amount of scale. Circulate the ISD solution for approximately 15 minutes each hour. 3. Try to keep the temperature of the ISD solution as described above. 9

Methods of Removing Scale 4. Check and record the ISD strength (Pink or Red color) at least once every hour. When it turns into yellow add more diluted solution of ISD. 5. When color remains red for more than two hours, the system is clean. 6. Drain the system by forcing the ISD solution out using clean water at 2 to 3 bars (29 to 43.5 psi) of pressure. 7. Fill the system with preheated water and soak at this temperature for 15 minutes. Drain under pressure 2 to 3 bars. 8. Drain and rinse system until the ph of the rinse water is between 7.5 to 8.0. Add sodium hydroxide if ph remains low for long time and re-circulate keeping ph at 8 for 30 minutes. 10

Methods of Removing Scale Precautions: Do not allow I-SOFT DESCALER (ISD) solution to remain in system or equipment for more than 24 hours. Always make sure that equipment room has sufficient ventilation to prevent the accumulation of gases. Cleaning of Evaporators / Heat Exchangers: Add I-SOFT DESCALER (ISD) de-scaling compound slowly to the tank of water, stirring if necessary until the desired quantity of I- SOFT DESCALER (ISD) is dissolved. A 5-20% solution can be prepared depending on the amount of scale to be removed. The solution may be heated by either the introduction of steam or the use of immersion heater. 11

Methods of Removing Scale If the system is badly scaled, it may be necessary to discard the cleaning solution and make a fresh batch. Cleaning is complete when the ISD strength holds constant for at least one hour as indicated by a steady Pink/Red color. Cleaning is generally accomplished in 2 10 hours. Drain the cleaning solution and flush the system with clean water. Refill with water and add the required amount of I- SOFT Scale and corrosion inhibitor. Adjust ph of circulate water to 8 8.5. Circulate for 1 hour and then drain the system. Inspect the system and return to service. 12

Properties & Packaging TYPICAL PHYSICAL PROPERTIES: Appearance Red Instant Powder Solubility in Water 20% at 16 C (60.8 F) ph of 10% solution 0.7 Flash Point N/A Packaging: I-SOFT DESCALER (ISD) is packed in 1 kg, 2 kg and 5 kg bags or 60 kg drums 13

Important Features and Benefits Features Free flowing Instant Powder. Contains Color indicator, does not require special test apparatus. Concentrate can be prepared according to the scale deposits. Contains the best corrosion inhibitor I-SOFT. Contains a wetting agent. Benefits Easy to ship, easy to handle and easy to mix and use. Easy determination of solution strength. Reduces cleaning time, very cost effective. Avoid any metal attack during cleaning, softens scale, can be used in any applications. Penetrates light, organic film and quick removal of scale. Start the system with Problems solved! FILTERSORB SP3 system (bicarbonate scale prevention) I-SOFT ON (Corrosion and bio fouling control) To avoid Future Problems 14

Conclusion Did you know? Dosing Phosphates cause scale: An understanding of the causes and effects of this increasingly common Heat Exchanger problem is crucial for effective treatment. Though the worse calcium phosphate scale is a newly discovered problem for the Heat Exchangers and cooling tower industry, it has long been recognized in the boiler industry. What is it? It s Calcium Phosphate Scale What causes scale? (Read more in Part II) End of Part I 15