New Approach to Energy Savings For Rooftop AC

Similar documents
Dehumidification: Energy Efficiency Comparisons

Adding More Fan Power Can Be a Good Thing

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

Dehumidification at Part Load

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review

Energy Recovery Ventilation

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

Dehumidifying with Dedicated Outdoor Air

ASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes

Designing Energy Efficient Outdoor Air Systems

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

ENGINEERING. Edition No. 13 October 2002

COMMERCIAL HVAC PACKAGED EQUIPMENT. Split Systems

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

product application data PERFECT HUMIDITY DEHUMIDIFICATION SYSTEM

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

2009 IECC Commercial Mechanical Requirements

Case Study of an Innovative HVAC System with Integral Dehumidifier. Florida Solar Energy Center Cocoa, Florida

CHAPTER 4. HVAC DELIVERY SYSTEMS

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

Benefits Offered by Passive Dehumidification Wheel Speed Control

APPLICATION GUIDE BEAMS

100% Outdoor Air Dehumidification Methods

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Field Test of Combined Desiccant-Evaporator Cycle Providing Lower Dew Points and Enhanced Dehumidification

Humidity Control Systems for Civil Buildings in Hot Summer and Cold. Winter Zone in China

DADANCO Technical Paper

Best Practices for Condensing Boilers

HONORABLE MENTION: COMMERCIAL BUILDINGS, EXISTING

NON-REVERSING, 100% OUTSIDE AIR HEAT PUMP FOR HEATING AND COOLING

Field Application of Advanced Residential Air Conditioning Systems

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

Achieving Dry Outside Air in an Energy-Efficient Manner

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

HVAC Mandatory Provisions Part II, Page 1

Submittal Data Performance Data Electrical Data

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

Relative Humidity in Schools Jim Cummings and Chuck Withers

TESTS OF ADSIL COATING

Active desiccant integration with packaged rooftop HVAC equipment

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Performance Rating of Variable Refrigerant Flow (VRF) Multi-split Air-conditioning and Heat Pump Equipment

Evaporative Cooling in a Hot-Dry Climate

By Thomas H. Durkin, P.E., Member ASHRAE, and James B. (Burt) Rishel, P.E., Fellow/Life Member ASHRAE

Air Conditioning for and-humid Climates:

RT-OA TM Rooftop Outdoor-Air (DOAS)

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

Summary Comparison of Simulation Program Features

COMcheck Software Version Mechanical Compliance Certificate

Product Release Summary

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

RoofPak Applied Rooftop Systems

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

Heat Recovery Units. Heat Recovery 1

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

ACHIEVING ENERGY-EFFICIENT DATA CENTER COOLING: DOES REDUCING FAN SPEED ALWAYS RESULT IN ENERGY SAVINGS?

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

Field Test and Performance Verification: Integrated Active Desiccant Rooftop Hybrid System Installed in a School

Do All DOAS Configurations Provide the Same Benefits?

REPRODUCTION/DISTRIBUTION IS PROHIBITED. Energy-Savings Strategies for. Rooftop

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

THE ULTIMATE ROOFTOP SOLUTION

ANSI/AHRI Standard 911 (SI) 2014 Standard for Performance Rating of Indoor Pool Dehumidifiers

4-Pipe VAV vs. Active Chilled Beams for Labs

Controlling Indoor Humidity in High Performance Homes. Danny Gough, Energy Solutions, LP

COMcheck Software Version Review Mechanical Compliance Certificate

Natatorium Economizer Vs. Conventional Dehumidifier

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

INSTALLATION INSTRUCTIONS

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

Interim Report for the Period thru February 15, 2018 Submitted to Department of Business and Professional Regulations Office of Codes and Standards

From 230 tons to. Water-Source Heat Pump Products. Premium Performance Environmentally Friendly Superior Construction

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Don t Turn Active Beams Into Expensive Diffusers

COMMERCIAL HVAC EQUIPMENT Coils: Direct Expansion, Chilled Water, and Heating

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

Urbana Free Library HVAC Analysis. Prepared for the Urbana Free Library. Prepared by Paul Boland, P.E., and Nathan Alderman, E.I.T.

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

Presented By: John Dolan, P.E.

Closing the Gap: Getting Full Performance from Residential Central Air Conditioners. Task 4 - Develop New Climate-Sensitive Air Conditioner

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Implications of GHP Fan Control Strategies on Humidity Control in Commercial Applications

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

HVAC 101. H V A C S y s t e m s

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Chilled Beams in Labs Eliminating Reheat & Saving Energy on a Budget

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

System Modeling of Gas Engine Driven Heat Pump

Optimizing Energy Efficiency and Improved Dehumidification Performance of Variable Capacity Air Conditioning Systems

Transcription:

New Approach to Energy Savings For Rooftop AC Authors Westphalen, Detlef Original Publication Detlef Westphalen, New Approach to Energy Savings For Rooftop AC, ASHRAE Journal, March 2004. his article may not be copied and/or distributed electronically or in paper form without permission of ASHRAE. Publication Number FSEC-GP-153-06 Copyright Copyright Florida Solar Energy Center/University of Central Florida 1679 Clearlake Road, Cocoa, Florida 32922, USA (321) 638-1000 All rights reserved. Disclaimer he Florida Solar Energy Center/University of Central Florida nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the Florida Solar Energy Center/University of Central Florida or any agency thereof. he views and opinions of authors expressed herein do not necessarily state or reflect those of the Florida Solar Energy Center/University of Central Florida or any agency thereof.

he following article was published in ASHRAE Journal, March 2004. Copyright 2004 American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. It is presented for educational purposes only. his article may not be copied and/or distributed electronically or in paper form without permission of ASHRAE. New Approach to Energy Savings For Rooftop AC By Detlef Westphalen, Ph.D., Member ASHRAE wo of the most important HVAC industry issues are energy efficiency and latent capacity. ANSI/ASHRAE/IESNA Standard 90.1-1999, Energy Standard for Buildings Except Low-Rise Residential Buildings, set new standards for the minimum energy efficiency ratios (EERs) of unitary air-conditioning equipment in the commercial capacity range. he U.S. Energy Policy Act of 1992 stipulated that these proposed energy levels would become mandatory, subject to a review by the U.S. Department of Energy. Even though that review is not complete, availability and sales of units with higher efficiencies have increased to reflect the changes in Standard 90.1. Prior to 1999, a standard efficiency 10- ton (35 kw) unit had an EER of 9.0. oday, a unit compliant with Standard 90.1-1999 has an EER of at least 10.1. However, EER is not the full story regarding seasonal energy use of an air-conditioning unit. he industry also has established an integrated part load value (IPLV), a weighted average of efficiencies for each capacity stage, which is intended to be a better indication of seasonal energy use. However, even the IPLV is not the full story regarding seasonal energy use. Since tests for both EER and IPLV involve 100% recirculating operation, these numbers do not capture the impact of outdoor air and the different ways that outdoor air can be conditioned. he airconditioning unit discussed in this pa- per incorporated design features intended to reduce seasonal energy use while it achieved good EER (10.8) and IPLV (14.1), it saved significant energy in a field test as compared with a conventional unit with the same EER. In the area of latent capacity, outdoor ventilation rates, which are prescribed by ANSI/ASHRAE Standard 62, Ventilation for Acceptable Indoor Air Quality, have been increasing in many cases. his trend has increased the proportion of the cooling load associated with moisture removal (the latent load) in non-arid climates. he reductions in sensible air-conditioning loads that result from using more efficient lighting, improved building materials, and other factors have contributed to increased importance of the latent load. Conventional unitary air-conditioning equipment has a sensible heat ratio About the Author Detlef Westphalen, Ph.D., is an associate principal with IAX in Cambridge, Mass. 38 ASHRAE Journal ashrae.org March 2004

he Florida Solar Energy Center s Building Science Laboratory, site of the field test of the prototype rooftop unit. (SHR) that is typically in the range % to 75% at standard ARI rating conditions. In many operating scenarios, the equipment latent capacity is insufficient to adequately dehumidify the air. Since air-conditioning units generally are controlled by thermostats, which respond to sensible loads, the result is excess humidity in the building space. his situation is exacerbated by the tendency of the condensed moisture that remains on the evaporator coil after the compressors cycle off to re-evaporate since the fan must run continuously to provide the required minimum outdoor airflow. 1 A number of technology options are available to treat moisture loads that exceed the levels typically handled by standard unitary equipment. he available options and those being developed represent a range of sophistication and efficiency. hey include reduced airflow, electric reheat, hot gas reheat, hot liquid reheat, 2 heat pipes, 3 evaporator bypass, passive energy recovery (passive desiccants, membrane), variable air volume (VAV), active desiccant systems (solid and liquid), and Cromer cycle. 4 he system design described in this article is an innovative combination of passive energy recovery and VAV intended to be cost effective, energy efficient, and flexible in a broad range of applications requiring low to medium outdoor airflow rates (i.e., offices, retail, etc.). he project described here addresses improvement of energy efficiency and performance of unitary air-conditioning equipment, an equipment category that is used for cooling in roughly three-quarters of commercial building floor space. IAX was awarded a DOE contract to develop the proposed energy-efficient air conditioner, with Aaon as the manufacturing partner. While the project s main focus was delivering maximum energy savings benefits at a minimum cost premium, the increasing importance of moisture control in all commercial air-conditioned environments made the focus on this issue also necessary. Analysis Phase he project started with examination of energy and cost characteristics of options for reducing energy use. hese options included improvement in all key components (compressors, indoor blower, condenser fan, blower and fan motors, heat exchangers), use of a zero-superheat variable expansion valve, total energy recovery for outdoor air, and mechanical subcooling. he costs and energy savings impacts of each of the design improvement options were calculated. Assumptions and results of this analysis are discussed in the project final report 7 and also in the online version of this article at ashrae.org. Based on the initial energy and cost analyses, we developed a design configuration incorporating the best design options: Increased heat exchanger size to achieve an EER of at least 10.3, consistent with the ASHRAE 90.1-1999 requirement for 10-ton electric-heat rooftop units; Variable air volume using an induction motor and inverter; March 2004 ASHRAE Journal 39

Energy recovery wheel (ERW); and Economizer. he design (called Configuration 1) is summarized in able 1. We also tested two additional configurations. he first of these, Configuration 2, used a tandem scroll compressor set including one variable-speed compressor. he second, Configuration 3, used a microchannel condenser and a tandem compressor set consisting of two single-speed compressors. We used aggressive interlacing in the design of the fin/round-tube heat exchangers to achieve highly efficient part-load performance with a separate refrigerant circuit Compressors Heat Exchangers: ype Condenser: ace Dimensions, in. (mm) Area, ft 2 m epth, in. (mm) Evaporator: serving each compressor. his design approach involves spreading out the circuits serving each compressor so that most of the heat exchanger s fin surface is used when just one compressor operates. Since this approach is not possible with microchannel heat exchangers, we used the tandem compressor set for Configuration 3, allowing refrigerant to flow during single-compressor operation through the entire condenser but only through one of the two conventional evaporator circuits. he cost of the energy-efficient design was calculated using the same methodology we used to evaluate design options. We estimated the manufacturing cost increase for the unit as $1,200, a 40% increase over the baseline 9 EER unit. However, the capacity enhancement for the ERW was estimated for a small office building with about 20% outdoor air to range from 15% to 35%. Hence, the net cost premium for this application ranges from 5% to 20% depending on climate. Cost premium as compared with a current Standard 90.1-1999- compliant unit was not evaluated but would be expected to be less. VAV Control he preliminary analysis showed that the energy impact of VAV is considerable, supporting our decision to incorporate it in our design. However, a concern regarding implementation of conventional VAV approaches was that controlling the supply air temperature by staging two single-speed compressors would have been quite coarse, resulting in supply temperature fluctuations. Other refrigerant-side control approaches, such as hot-gas bypass and suction line throttling, were considered undesirable because they did not meet our focus on energy. Airside control involving air bypass to the return was rejected for the same reason. We developed a new approach to VAV that uses modulation of the blower rather than of cooling to control the supply High-Efficiency Design (Configuration 1) wo 5-ton ZP54 scroll Fin/Round ube F 46 x 72 (1168 1829) ( 2 ) 23 [2.14] D 1.8 [46] (2 Rows) Face Dimensions 40 42 (1016 1067) A rea 11.7 (1.09) D epth 2.7 (69) (3 Rows) arget COP [EER (Btu/W-h)] 10.3 (3.02) Expansion Device nergy Recovery Wheel Main Blower: Wheel Motor Variable Frequency Drive Variable Expansion Valve Airxchange ERC-302 1 Acme 185 BC Plenum Fan hree-phase 208V 3 hp Motor Baldor 15J Minidrive Acme 1 BC Plenum Fan hree-phase 208V 1 hp Motor E 0 Exhaust Blower Condenser Fans (2) Revcor KH2404-29 hree-phase 208V hp Motor Dampers: Model Number Ruskin CD Face Dimensions, in. (mm): 34 7.5 (864 191) Outdoor 36 20 (914 8) Return 36 14 (914 356) D amper Actuators Belimo LM245R (Proportional) 1. 30-in. wheel size, design airflow 2,000 cfm at 1 in. w.c. pressure drop. able 1: Energy efficient AC unit design summary. air temperature. Figure 1 illustrates this approach, called reverse VAV. It reverses the way in which air volume is adjusted. Under conventional control, space temperature sensors affect the throttling of terminal box valves, and the blower is modulated to deliver the required flow while maintaining desired duct pressure. he cooling coil capacity is adjusted (through compressor cycling or modulation, or chilled water valve modulation) to control the supply air temperature. In the reverse approach, the compressor plant operation (staging or modulation, depending on the compressor) is adjusted based on space temperature, and the blower responds by adjusting airflow to maintain a desired supply air temperature. One of the striped arrows in Figure 1 shows that terminal box zone control can still be adjusted on the basis of space temperature. he second striped arrow illustrates the adjustment of airflow to respond to space humidity conditions. In practice, this can be done by adjusting the desired supply air temperature setpoint. For example, the setpoint would be allowed to modulate from 7.2 C (45 F) to 15.6 C ( F). When the space needs more dehumidification and less sensible cooling, the setpoint would be reduced. he blower speed would drop to reduce airflow so that the lower setpoint can be achieved. When the space requires less dehumidification, the supply air setpoint is increased, leading to an increase in airflow. his approach allows decoupling of sensible and latent control of the space, allowing for use of reduced airflow to en- 40 ASHRAE Journal ashrae.org March 2004

hance dehumidification when it is appropriate, but operating with high airflow when there is less moisture load. he benefits of reverse VAV, particularly in unitary systems, are as follows: Cost Savings. Blower speed rather than compressor modulation is used to set the supply air temperature. Options for modulating blower speed are available off the shelf at reasonable cost and are already part of any VAV installation. his avoids the additional cost of modulation for the compressor. he approach allows for implementation of VAV without the need for expensive VAV terminal units. Better zone control is possible with the use of conventional VAV terminal units, but could also be provided with less expensive zone dampers, or, depending on zone diversity, with no dampers. Humidity Control. Most conventional systems only provide temperature control for the building, but this approach attempts to control both temperature and humidity. he airflow rate is modulated to better match the sensible heat ratio (SHR) required by the conditioned space. Ease of System Upgrade. he reduced zone airflow control requirements allow this VAV system to be retrofit into buildings that currently have constant air volume (CAV) systems without the need for the entire air-distribution system to be modified. his represents a significant market opportunity because it allows much easier system upgrade when an old inefficient unit is replaced. Conventional VAV Reverse VAV Comp. Compressor Blower erminal Box Space Comp. Evap. Evap. Compressor Blower erminal Box Space Figure 1: Contrast of conventional VAV and reverse VAV. Energy Recovery Wheel Integration he air-conditioning unit design was intended for applications with moderate percentages of outdoor air. he energy recovery wheel (ERW) was selected with a design flow of 2,000 cfm (944 L/s), up to about half of the unit s maximum total airflow. While this is a higher flow than would be considered moderate, the selection allows for a broader range of system applicability and it results in reduced blower power input. he wheel incurs 1 in. w.c. (249 Pa) of pressure drop at the design flow rate. Although the concept of recovering energy from exhaust P H air to precondition incoming outdoor air is straightforward, integrating the ERW into the unit can be complex. Some of the issues are illustrated in Figure 2. First, an exhaust blower is required to draw the exhaust air through the wheel, since the wheel s pressure drop is not negligible. he pressure drop on the outdoor air side of the ERW can be provided by the main blower or by an additional outdoor air blower. We used the main blower in this project. his may require that throttling occur in the return dampers to ensure that equal pressures of outdoor and return air enter the mixing box, depending on the pressure in the return plenum. We mitigated the energy penalty associated with return damper throttling by using VAV. However, because the unit operates with VAV, the positions of the return and outdoor dampers must be modulated as the main blower speed modulates to ensure the constant flow of outdoor air through the Energy Recovery Wheel Optional OA Blower to Reduce otal Blower Power Intake Hood Makeup Air Exhaust Air Directed Away From Intake Hood o Prevent Recirculation Exhaust Blower Economizer Dampers o Bypass Air Around ERW for Economizer Cooling Return From Space Mixing Box Optional Separated oilet or Other Exhaust Separate Duct to Prevent Recirculation Where Required Cooling Coil Return Damper o Ensure Proper Exhaust and Makeup Airflow Gas Furnace Supply Air Main Blower Larger to Handle Increased Pressure Drop Figure 2: Integration of an energy recovery wheel in an air-conditioning unit. March 2004 ASHRAE Journal 41

Unit Configuration 1 2 3 Compressors wo 5-ton SS andem, VS andem, wo 5-ton SS Condenser Conventional Conventional Microchannel Evaporator Conventional Conventional Conventional emperatures, F ( C) Condensing 117/113 109 (47/45) 1 (43) Evaporating 51/51 51 (10.6/10.4) 1 (10.3) Capacity Rating Point otal Capacity, Btu/h (W) 119,000 (34 900) 112,000 (32 900) 113,000 (33 100) Sensible Capacity, Btu/h (W) 86,000 (25 200) 77,000 (22 0) Sensible Heat Ratio 72% 68% Power Input (W) 11,010 12,100 10,4 EER, Btu/h-W (COP [W/W]) 10.8 (3.16) 9.3 (2.72) 10.8 (3.16) IPLV Btu/h-W (W/W) Staged Condenser Fans 13.1 (3.84) 13.8 (4.04) Constant Condenser Fans 12.8 (3.75) 14.1 (4.13) 1. he two temperatures represent the two refrigeration loops. able 2: Capacity, EER, and IPLV test results. ERW. he pressure drop across the ERW is used as an indicator of flow rate. As blower speed drops, the outdoor damper must open more and the return damper must throttle more, since the return duct pressure drop gets lower while ERW pressure drop remains constant. Another issue is how to incorporate economizing. A large amount of outdoor air must flow during economizing operation, which would incur excessive pressure drop across the ERW. herefore dampers are needed to allow air bypass around the ERW for both the outdoor air and the exhaust air. An additional possible operating mode occurs when the ambient air is too warm to use for economizing but not warm enough so that compressor power savings are greater than blower power increase when using the ERW. We did not incorporate this operational mode in the tested prototype. Laboratory esting We conducted laboratory testing primarily to evaluate capacity, EER, and IPLV for the conventional configuration as compared with the variable-speed and microchannel configurations. he unit configurations and the test results are summarized in able 2. he conventional unit design, with an EER of 10.8, exceeded the 10.3 target. he high IPLV levels result from the aggressive heat exchanger interlacing. Note that IPLV was better with staged condenser fans. his is also the result of the condenser interlacing, which allows the refrigerant to transfer heat to all of the reduced condenser airflow during part load. Net Capacity, Btu/h (W) Sensible Heat Ratio COP, Btu/h-W (EER) IPLV, Btu/h-W (W/W) Curb Footprint, L W, in. (m) Max. Dimensions, in. (m) Weight, lb (kg) Evaporator Face L W D, in. (m) Face Area, ft 2 (m 2 ) Condenser Face L x W, in. (m) Face Area, ft 2 (m 2 ) Number of Condenser Fans Fan Blade Dia., in. (m) Conventional Unit Standard Unit at 3,0 cfm 131,000 (38 400) ested Unit at 4,0 cfm 132,300 (38 0) High Efficiency Prototype ested Unit, With Hot Liquid Reheat, at 4,0 cfm 125,0 (36 0) Configuration 3 (Microchannel Condenser) 113,000 (33 100) 1 64% 69% % 68% 10.8 (3.16) 11.6 (3.40) 10.7 (3.14) Not known 86 84 (2.2 2.1) 86 84 45 (2.2 2.1 1.1) 1,725 (784) 36 3 (1.8 x 0.9 0.076) 10.3 (3.02) Not known 128 (3.3 1.3) 10.8 (3.16) 14.1 (4.13) 128 87 52 (3.3 2.2 1.3) 1,782 (810) 42 40 2.7 (1.1 1.0 0.069) 17.5 (1.63) 11.7 (1.08) 82 40 (2.1 1.0) 21.7 (2.01) 72 46 (1.8 1.2) 23 (2.14) 3 2 22 (0.56) 24 (0.61) 1. Not including impact of energy recovery wheel. able 3: Comparison of conventional and new design units. Configuration 2, which used the variable-speed tandem compressor, had poor EER but good IPLV. his is because the variable-speed compressor efficiency was very good at low speed but very poor at high speed. For the ARI capacity rating point, the variable speed compressor s input power was about 1 kw higher than that of the single-speed compressor of the tandem set. Configuration 3, with the microchannel condenser, had reduced capacity with EER equal to that of Configuration 1. he use of a microchannel condenser and conventional evaporator required the use of a receiver for the tested unit to avoid pressure fluctuations associated with charge mismatch of the heat exchangers. When operating with a receiver, the hot liquid has nearly zero subcooling, which reduced capacity, but the condenser is used entirely for condensing, which helped further reduce the condensing temperature and compressor power input. he IPLV for the microchannel configuration was very high, due to the use of the tandem compressor set for this configuration. Use of sepa- 42 ASHRAE Journal ashrae.org March 2004

emp. ( F) 90 85 75 Space emp. Space RH 75 RH Percent emp. ( F) 90 85 75 Space emp. Space RH 75 RH Percent 6:00 8:00 10:00 12:00 14:00 16:00 18:00 20:00 ime of Day 6:00 8:00 10:00 12:00 14:00 16:00 18:00 20:00 ime of Day Figure 3: Comparison of prototype (left) and conventional unit maintenance of space conditions. rate compressor loops with microchannel heat exchangers would have resulted in less impressive IPLV, since the available microchannel technology did not allow interlacing. Field esting We conducted a field test at Florida Solar Energy Center s (FSEC s) Building Science Laboratory to compare the performance of the prototype rooftop unit with a conventional unit that uses hot liquid reheat, which is an energy-efficient approach to enhancing latent capacity. We chose a conventional unit with capacity greater than 10 tons to demonstrate the capacity enhancement of the ERW. he units are compared in able 3. We connected both units to a common ducting system serving the building, with shutoff dampers that would allow switching between the two units. he conventional unit was set up to cycle the hot liquid reheat based on a space humidistat. he facility is a highly instrumented test building with simulated internal loads that allowed careful comparison of the performance and energy use of the two units. he Florida location was chosen not only because of the FSEC facility, but also to allow testing of the dehumidification capabilities of the new design. he test building was set up to simulate a small office building typical of Florida construction. Space RH Percent 45 40 35 30 he outdoor ventilation flow was 840 cfm (396 L/s), and the units were set up for a 4,0 cfm (2124 L/s) maximum total airflow. Estimated total peak load (including ductwork thermal losses) was 32 100 W (109,400 Btu/h) with a 64% SHR. We established a schedule for activation of the loads and operation of the HVAC equipment to represent the office application. esting was conducted between August 2002 and January 2003. he cooling performance of the two units was comparable. Figure 3 shows the performance on two days with similar ambient conditions. Since both units had two single-speed compressors, they both provided cycling O Conventional X Prototype 0 0.005 0.01 0.015 0.02 Outdoor Absolute Humidity (lb/lb Dry Air) Figure 4: Humidity control comparison. control of the space temperature. he humidity control of the prototype unit was tighter, due to the ability to adjust airflow rate to respond to dehumidification needs. Even so, humidity fluctuations were not entirely avoided. he airflow modulation control was set up with moderate-speed response to avoid instability. Hence, the system does not immediately reduce airflow and bring space humidity back down. he latent performance of the prototype unit was not sufficient to prevent rise of the space relative humidity during single-compressor operation for the most humid conditions. It is anticipated that further optimization of the control system would help alleviate these fluctuations. March 2004 ASHRAE Journal 43

Daily Energy Use, kwh 1 140 120 100 40 Conventional Prototype 20 0 40 90 Avg. Daily Outdoor emp. ( F) Evaporator Condensate, lb/day 0 0 0 400 300 200 100 0 Conventional Prototype 30 40 Avg. Daily Outdoor Dew-Point emp. ( F) Figure 5: Daily energy use and evaporator condensate comparison. Figure 4 compares humidity control of the two units. It shows that the prototype unit provided better dehumidification (space relative humidity is reduced by 3% to 5%) in warmer conditions when two compressors were likely to be operating. For less severe conditions, in which a single compressor was likely to be operating, the prototype unit humidity control was not as good, reflecting the part-load issues discussed above. For less severe conditions, humidity levels were lower, reflecting added dehumidification provided by the outdoor ventilation air. Energy use of the two units is shown in Figure 5. For the test period, the energy use of the prototype unit was about 25% lower than that of the Conventional unit. While this might be expected based on the IPLV ratings of the units (14.1 vs. 11.6), the IPLV doesn t tell the whole story, since it is measured with the unit operating at full airflow in allreturn mode. he part-load efficiency of the refrigeration circuit was probably not as good in the field as the 14.1 IPLV suggests, because of the tendency of the unit s airflow to be reduced at part load to maintain latent performance. However, use of the ERW is not incorporated in the IPLV, and the ERW is clearly a factor in reducing the energy use of the prototype unit. Daily measurements of condensate collected from the units evaporator drip pans, shown in Figure 5, show the significant latent load contribution of the ERW. Conclusions he energy-efficient rooftop unit design took advantage of the most cost-effective design options, resulting in better performance than that of a conventional 10.8 EER rooftop unit while using about 25% less energy. his work illustrates the point that EER is not the full story regarding system energy use. he design options that contribute most to the unit s energy savings are VAV, an energy recovery wheel, heat exchanger interlacing, and the microchannel condenser. he use of a new reverse-vav approach for system control provided good humidity control during the field test and offers a way to use VAV in small-to-medium size unitary systems. he applied cost premium for the unit, as compared with current typical air-conditioning units, is expected to average about 10% if the unit is manufactured in sufficient quantity. his system development addresses the current industry emphasis on improved humidity control and reduced energy use without significantly increasing cost. In addition, the work has helped illustrate the individual benefits of the key technologies incorporated into the design. Acknowledgments hanks to the many people who helped make this work possible, including Esher Kweller, P.E., Member ASHRAE, of the U.S. DOE; Steve Pargeter, Member ASHRAE, and Brent Stockton of Aaon; Wayne Warner of Copeland; Greg Kohler, Member ASHRAE, of Modine; Bede Wellford, Member ASHRAE, of Airxchange; Rick Reeves of Acme; Rumin Raykov of Cambridgeport; Bill Walter, Member ASHRAE, of Carrier; and Don Shirey, Member ASHRAE, and Richard Raustad of FSEC, as well as many at IAX. References 1. Henderson, H.I. and K. Rengarajan. 1996. A model to predict the latent capacity of air conditioners and heat pumps at part-load conditions with constant fan operation. ASHRAE ransactions. 2. www.invironment.com/newsletter/v2n8g1.pdf 3. www.eere.energy.gov/consumerinfo/refbriefs/bd2.html 4. www.oit.doe.gov/inventions/factsheets/solareng.pdf 5. Huang, J. 1990. 481 Prototypical Commercial Buildings for wenty Urban Market Areas. Lawrence Berkeley National Laboratory. 6. Huang, J. and E. Franconia. 1999. Commercial Heating and Cooling Loads Components Analysis. Lawrence Berkeley National Laboratory. 7. IAX. 2003. Energy Efficient Rooftop Air-Conditioner, prepared by IAX for NEL/DOE. www.tiax.biz/aboutus/pdfs/ rooftop_ac_report_0625-03.pdf. 44 ASHRAE Journal ashrae.org March 2004