POINT FLASHING BEACON PFB EX LED HAZARDOUS AREA CLASS I, DIVISION 2

Similar documents
POINT ROLLOVER LIGHTS PRL LED HELIPORT INSET LIGHT

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

POINT ROLLOVER LIGHTS PRL LED HELIDECK SEMIFLUSH LIGHT

POINT HELIDECK LIGHTS PRL-LSM LED LOW SURFACE MOUNT LIGHT

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

POINT STATUS LIGHTS PSL LED HELIDECK STATUS LIGHT SYSTEM SAFE AREA & CLASS I, DIVISION 2 (ZONE 2)

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

Heliport & Helideck Lighting System. For Non Hazardous and Hazardous Locations. Option: Marine Treatment for superior corrosion protection

SUPPLEMENTAL INSTRUCTION SHEET POL S2 POINT OBSTRUCTION LIGHT SINGLE WITH ALARM

Obstruction Lighting Guide

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

D564A13002GPS D564A15002GPS Medium Intensity Obstruction Light FAA Compliant

Applications. Standard Materials

Vigilant LED Based Obstruction Lights

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps

1. PURPOSE. This advisory circular (AC) contains the Federal Aviation Administration (FAA) specification for obstruction lighting equipment.

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

Vigilant LED Based Obstruction Lights

Vigilant LED Based Obstruction Lights

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

Lighting for Hazardous & Severe Environments

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

Tower & Obstruction Lighting

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

Choice of factory set distributions. Thermally set white polyester powder paint. Optional wet location listing

Dialight Obstruction LED Solutions

AWL AIRCRAFT WARNING LIGHT LIOL-B TYPE OPERATION AND MAINTENANCE MANUAL

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

standards: standards:

Obelux MI-2KR-A Page 1/5 ICAO Medium Intensity Type B and C, FAA L-864 and L-885, cd flashing / fixed red obstacle light

33 Watt Low Voltage LED Fixture for Hazardous Location Lighting - Low Profile Linear Fixture - C1D2

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

Ultrasonic Point Level Switches

XLFE-4/1. Borosilicate glass globe

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Product Specifications MaxLumen MRI LED Diffused Lighting

LIGHTING TEF 9980 STATUS LIGHT, MAIN LIGHT & REPEATER LIGHT ZONE 1, ZONE 2 & SAFE AREA USER MANUAL

Certificate of Compliance

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

Ultrasonic Switches. Features & Benefits

Tankless On Demand Electric Water Heater

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

300W EXP LED Light - 35,000 Lm - 3' Cart Mount - Quick Change Mount - C1D1-100' 16/3 SOOW- EXP Plug

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

Class 1 Division 2 Hazardous Location Stack Light - Signal Traffic Light - Multiple Lamp Colors

Explosion Proof LED String Lights - 5 Hand Lamps - Class 1 & Class 2

LMV Series W Low Profile - Medium Base

Rating. Class I Div II

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

DuroSite Series LED High Bay - UL for Indoor and Outdoor Industrial Applications. Patent Pending

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

4' 2 Lamp Fluorescent Light Fixture - Emergency Battery Backup - T8 Bulbs - Multi-voltage - CID2

INTRODUCTION / TABLE OF CONTENTS

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

EVLPF Series Compact Fluorescent

DB4 Range - SPEAKERS - Up to 25 Watts

CX1 ProVector Explosion-Proof Heaters

Evolve LED Garage Light

PRODUCT CATALOG HUGHEYANDPHILLIPS.COM

TLM-1 TOWER LIGHT MONITOR V3.0. INSTALLATION and OPERATING INSTRUCTIONS

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Approved by: Document no.: EGT

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

POWER AND CONTROL PRODUCTS QUICK RESPONSE PROGRAM.

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

power HaZ-LOC MAGNET-SCHULTZ OF AMERICA Harness the of collaborative innovation Hazardous location Engineered for safety critical markets

Circulation Heaters Selection Guidelines

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

Description. Applications

4300 WINDFERN RD SUITE 100 HOUSTON TX VOICE (713) FAX (713) WEB: IMPORTANT!!!

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

AWL AIRCRAFT WARNING LIGHT MIOL-AC & MIOL-C TYPE OPERATION AND MAINTENANCE MANUAL

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

LED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light

DWA2000. WAAS Annunciator. Installation and Operations Manual. Rev 1.0 August 2014

PANELBOARD PROTECTION ON A GLOBAL SCALE

4300 WINDFERN RD SUITE 100 HOUSTON TX VOICE (713) FAX (713) web: twrlighting.com IMPORTANT!!!

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Certificate of Compliance

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

SECTION LOW VOLTAGE LIGHTING CONTROLS

Date: 9/28/2016 Initiated By: AAS-100

Accessory Products

Rogue 4 specializes in extreme output high performance LED lighting.

Transcription:

Compliances: Class I, Division 2, Groups A B C D, T6 Class I, Zone 2, Groups IIA IIB+H2 IIC, T6 ETL Verified FAA L-864 to FAA Advisory Circular 150/5345-43G Compliance to ICAO Annex 14 Medium Intensity Types B & C Registered ISO 9001:2008 Compliance to UK CAP 168 Medium Intensity & Low Intensity (Group B) ETL Listed to UL 844 & UL 1598; Report No. 100066593CRT-002a ETL Listed to UL 1598A Marine Vessels ETL Listed to CSA C22.2 No. 137-M1981 & No. 250.0-04 Canada ICAO Annex 14 Medium Intensity Types B & C Army TM 5-811-5, para. 7-5.c. Hazard Beacon American Bureau of Shipping (ABS) Type Approved Product The PFB-EX LED red medium intensity flashing beacon is specified for use on aviation obstructions. All castings are aluminum, all hardware is stainless steel and the lens is glass. There is no plastic. All exterior metal beacon parts are powdercoat painted for corrosion resistance to US Military Standard Salt Fog Test conducted per MIL-STD-810F, Method 509.3, Procedure I. Note: FAA L-864 certified in red. Point Type Color Voltage Rating Options PFB-37001 R: Red 1: 120 volts ±20% EX: Explosion-Proof SEE TABLES C: Clear/White 2: 220 volts ±20% Class I, Division 2 ON PAGES 2 & 3 G: Green 3: 12 VDC Class I, Zone 2 Y: Yellow 4: 24 VDC FEATURES 5: 48 VDC Flasher failure alarm; beacon remains ON PFB-37001-R-1-EX LED array failure alarm Over voltage & over current protection Short circuit & open circuit protection Metal oxide varistor surge protection No external plastic parts Replaceable LED array sections (5) Intensity: Wattage: Volt-Amps: 2,000 candelas as defined in FAA Advisory Circular 150/5345-43G 70.2 watts Peak (AC) 52.5 watts Average (AC) 79.6 watts at 12V DC 56.3 watts at 24V DC 110.4 VA (120V AC only) Input Range: Temp Rating: ± 55 C 93 to 144 volts (120V unit) 176 to 264 volts (220V unit) Intertek Control Number 3030033 Dimensions: 15 (381) x 15 (381) x 12 (304) H Inches (mm) OL-2.1.6 July, 2014

The basic PFB-37001-EX beacon catalog number is intended for use with a Point POC Controller for most applications. Other configuration options below are available to be factory installed at time of order. Add the separate FAA Photoelectric Controller to all systems. Add the separate SPU Surge Protector Unit or POC Controller as required by the system. UNIVERSAL OPTIONS MT The fixture shall be treated for marine conditions by cleaning per US Department of Defense TT-C- 490 method III, pretreated with chrome-free aluminum conversion coating per US MIL-C-5541 type II, epoxy powder base coat primer and glossy polyester powder coat finish in color RAL 6003 (FED- STD-595 color #14097) dark green. Powder coating per US Department of Defense MIL-PRF-24712A type VI and oven cured. BACKUP OPTIONS SB Standby Beacon: add this option to the 2 nd beacon to operate upon failure of the primary beacon. This standby beacon & the primary beacon will be stacked and interconnected. ICAO OPTIONS The basic beacon is FAA L-864 style. Specifically, failure of any FAA LED array results in all arrays turning OFF; partial failure results in no light output. The options below are ICAO (international) versions; if one array fails, an alarm is generated and the beacon remains ON. B C ICAO Medium Intensity Type B (flashing) ICAO Medium Intensity Type C (steady-burning) and UK CAP 168 Medium Intensity Obstacle D UK CAP 168 Low Intensity (Group B) (steady-burning) Table 6A.1 & CAP 437 paragraph 4.4 OPTIONS CONTINUE ON PAGE 3 PFB BEACON WITH TRANSFER TO STANDBY BEACON UPON FAILURE PRIMARY PFB BEACON PFB-37001-R-1-EX ASSEMBLED WITH STANDBY PFB BEACON PFB-37001-R-1-EX-SB

The basic PFB-37001-EX beacon catalog number is intended for use with a Point POC Controller for most applications. Other configuration options below are available to be factory installed at time of order. Add the separate FAA Photoelectric Controller to all systems. Add the separate SPU Surge Protector Unit or POC Controller as required by the system. ALARM CONFIGURATION OPTIONS K Required on each beacon when installed with any POC-68001 series digital controller. The options below are required when the beacon is installed without a POC controller. One of the SA options is required for a single beacon installed without a controller. The MA options are required for two or more synchronized beacons installed without a controller. For more than four (4) beacons, a POC controller is required. SA1 SA2 MA1M MA1S Single beacon with internal flasher & non-isolated alarm line powered by the line voltage Single beacon with internal flasher & voltage free alarm line to be powered by a remote AC or DC source supplied by others (isolated alarm line) Master beacon to be synchronized with one or more secondary beacons with internal flasher & nonisolated alarm line powered by the line voltage; one master beacon per system. Secondary beacon synchronized by the above master beacon with internal flasher & non-isolated alarm line powered by the line voltage; 1 to 3 secondary beacons per system. RECOMMENDED OR REQUIRED ACCESSORIES SPU POC PPC Each beacon contains limited surge protection. All POC controllers include circuit level surge protection. For systems without a POC, an SPU Surge Protector Unit is strongly recommended: SPU-10770-x x = 1 for 120v x = 2 for 220v Separately ordered and separately installed in the line feeding power to the beacons. Specify Class I, Division 2 is required. See file OL300POC for a POC-68001 series system controller with touch screen option (not hazardous area). Specify Class I, Division 2 POC custom unit if required. One FAA Photoelectric Controller is required per system. Separately ordered and separately mounted. PPC-40002-EX Class I, Division 2, for AC systems with a POC Controller

SPECIFICATION The PFB POINTSPEC TM series LED red beacon shall comply with FAA L-864 and ICAO medium intensity Types B and C. The beacon shall be listed and labeled for Class I, Division 2. Sealed to IP66 ingress protection. Alarms shall be generated for flasher failure, LED array failure, over voltage, over current, short circuit and open circuit. The high intensity LED arrays shall be replaceable and fitted with plug-in connectors. All hardware shall be stainless steel. All exterior aluminum cast beacon parts shall be powdercoat painted aviation yellow for corrosion resistance that meets the US Military Standard Salt Fog Test conducted per MIL-STD-810F, Method 509.4, Procedure I. The clear lens shall be made of strong soda-lime glass manufactured by Kopp Glass. There shall be no plastics used in the structural construction of the beacon. OPTIONAL PL40139 HEAT SHIELD The beacon heat limit is 55-deg C. Installation in higher temperature locations is not warrantied. The heat shield shall be installed suspended in the air space between the heat source and the beacon. The heat shield shall be fabricated of a rigid alumina fiber matrix that shall remain stable for continuous use at temperatures up to 3128-deg F (1720-deg C). The material shall not be affected by oil or water and shall be resistant to chemicals. Note: Do not use in the presence of hydrofluoric acid, phosphoric acid & very strong alkalis. The heat shield shall be 24-inches wide by 36-inches high. The shield should to be oriented as required to maximize protection. See OL-8.3.0 for Heat Shield drawing POC SYSTEM CONTROLLER WITH OPTIONAL TOUCHSCREEN (DIGITAL NEMA 4X UNIT SHOWN) The PL40139 Heat Shield shall limit transmission of heat in accordance with these tested temperatures: STACK FACE BEACON FACE 800 252 F 1200 343 F 1600 F 429 F These temperatures are surface measurements on opposite faces of the PL40139 Heat Shield. It is expected that the air spaces between the stack skin and the shield and between the shield and the beacon will further limit the heat transmission. FAA PHOTOELECTRIC CONTROLLER PPC-40002-EX

SPARE PARTS & SERVICE Do not open the beacon unless there has been an in-service failure. Opening the beacon before installation voids the warranty. See the instruction manual for troubleshooting procedures. All service must be performed inside a maintenance facility under clean and dry conditions. See the instruction manual for a list of field serviceable parts. Contact Point Lighting for return repair service instructions. Do not attempt any testing or repair procedure not stated in the manual. Hole Diameter 11/16 (17.5) Beacon Mounting Pattern Bolt Square 9-3/8 (238) per side TYPICAL BEACON CABLE PIGTAIL Length: Two (2) meters Type: SOOW 600-volt Wires: Six (6) each #16 AWG TYPICAL SYSTEM WIRING Bolt Circle 13-1/4 (337) PRESET TORQUE TOOL PL10872 For Sealing Nut to reassemble PFB Dimensions: Inches (mm) Not to Scale Power (3): Line-Neutral-Ground Typically #12 AWG From POC or SPU Alarm (1+): One (1) alarm line per PFB Typically #16 AWG Data (2): One (1) flash synchronization One (1) Return Typically #16 AWG See manual for specific wiring schemes REPLACEMENT PARTS PL10754 Lens, Outer Clear PL10807 Gasket, Lens Upper PL10818 Sealing Nut (see tool PL10872) PL10806 Gasket, Lens Lower PL10834-x LED Array Section PL10825-EX Motherboard (-EX) PL10824A Power Supply LED PL10821 Surge Protector AC PL10808 Power Supply AC-DC PL10823 Surge Protector DC See Instruction Manual for parts specific to the version installed at specific location. P O I N T L I G H T I N G C O R P O R A T I O N Mail: P.O. Box 686, Simsbury, CT 06070 Plant: West Dudley Town Rd, Bloomfield, CT Tel 01 860.243.0600 USA Fax 01 860.243.0665 email: Info@PointLighting.com website: www.pointlighting.com