THB4002. GoTemp Food Infrared Thermometer With Laser Sighting And Thermocouple Jack User Guide. Measuring Temperature The Smart Way.

Similar documents
Optima ZigBee Thermostat

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

2 x screws. 2 x wall plugs

ShockLink. Important Product Information.

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

InTemp CX Temperature Logger (CX40x) Manual

Automatic Dimming Mirror with HomeLink

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

SZ-PIR04N ZigBee Motion Detector Installation Guide

OPERATION MANUAL WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT.

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

Smart Hub THERMOSTAT. Installation Manual

Wireless External Alarm

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator

Wi-Fi DOOR/WINDOW SENSOR

100 Ft. LASER DISTANCE METER

ADT. Pulse 2017ADT LLC

Intelli-Time Alarm Clock model 13041RM

Smart THERMOSTAT. Installation Manual

Pet Immune SAW PIR Motion Sensor

HOBO MX Temp/RH Data Logger (MX1101) Manual

Wireless Weather Station

Atomic Digital Office Clock

1100D Wireless Receiver

Water Sensor. Model CFWS10

Installation Guide. Model TBZ48A Battery Powered Z-Wave Thermostat. This thermostat is compatible with most HVAC systems, including the following:

Door/Window Sensor Installation Instructions

Rev D 3/20/17

Digital Refrigerator/Freezer Thermometer model 00986

Thermometer with Wired Sensor

1100X Wireless Receivers

Thermometer model 02059

TX3 Series. TX3 InSuite. User Guide

Wireless Outdoor Air Reset Adaptor PN:

EL-TSTAT Owner s Manual

OPTIMA ZigBee Thermostat

Model:T83646v2 Quick Setup Guide DC: WIRELESS WEATHER STATION

EN1221S-60 Waterproof Pendant Installation and Operation Manual

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

Draft - develop and review

Weber igrill App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Disconnecting 6 Mounting 7 Probe Use 8 Probe Wrap Use 9

S541.RF 4G Product Guide

Features and content. This is where air comes into your detector.

Touchscreen Comfort Control

CLIP PG2 PowerG Wireless, Curtain, PIR Motion Detector

idevices Connected App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Mounting 7 Probe Use 7 Probe Wrap Use 9

Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons.

Infrared Thermometer

ecobee 3 Quick Start Guide Installation Guide DRAFT

I/R Thermometer Gun 12:1

safety & regulatory information

PIR Sensor. User s Guide

Humidity Monitor model 01080

Infrared Thermometer. Getting Started

IMPORTANT. Questions? Contact Customer Support at (877) or visit 5-in-1 PRO+ Weather Sensor model

TABLE OF CONTENTS. Box Contents...3. Quick Start Instructions Important Information Intended Use Meat Probe Use...

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

IRT2 Dual Laser IR Thermometer - User Guide

TABLE OF CONTENTS. Box Contents...3. Quick Start Instructions Important Information Intended Use Meat Probe Use...

SkyNEST WASP Portable Kit, Smart Receiver and SCADA Gateway with Solar Panel USER MANUAL

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

IMPORTANT. 3-in-1 Weather Sensor model SAVE THIS MANUAL FOR FUTURE REFERENCE. Package Contents

Owner s Manual. PIR-1 IR Learner

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Ambient Weather WS-09 8-Channel Wireless Refrigerator/Freezer Thermometer User Manual

Smoke Bridge Owner s Manual

Thermometer with Probe model 00891A

Smart Radon Detector with Indoor Air Quality Sensors Version 1, May 8, 2018

ZTS-500US Z-Wave Smart Thermostat

Dual Laser InfraRed (IR) Thermometer

Ambient Weather WS Channel Wireless Thermometer with Min/Max Display User Manual

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

Ambient Weather WS-16 8-Channel Wireless Thermometer with Min/Max Display User Manual

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

TABLE OF CONTENTS. Box Contents...3. Quick Start Instructions Important Information Enhance Your Assembly Experience. Intended Use...

3M Benchtop Air Ionizer 963E. User s Guide

PET IMMUNE PIR MOTION DETECTOR

Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display User Manual

Manual Instructions IR Measuring Instrument GIM 1840 ST60 / ST80

FTS05 / FTS05P - Wireless Flood and Temperature Sensor, User Manual

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

CONNEX Smart Thermostat CST R00

Weber igrill App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Disconnecting 7 Mounting 7 Probe Use 8 Probe Wrap Use 9

Smart Radon Detector with Indoor Air Quality Sensors

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

Installer Guide smart connect

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Instruction Manual. AcuRite Atlas Outdoor Device model 06059

64 Max IR Thermometer

Installer Guide smart connect

Impassa CDMA Module INSTALLATION GUIDE

Technical support is also available by or by phone: (North America) (International)

CLIP PG2. Installation Instructions. PowerG Wireless, Curtain, PIR Motion Detector 1. INTRODUCTION 2. INSTALLATION. 2.1 General Guidelines

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

Transcription:

THB4002 GoTemp Food Infrared Thermometer With Laser Sighting And Thermocouple Jack User Guide Measuring Temperature The Smart Way Provided by

Table Of Contents Description... 3 Features... 4 Distance to Spot... 4 Reset... 5 Indicators... 5 Bluetooth & Pairing... 6 Specifications... 7 Proper Application and Operation... 9 Power Switch... 11 Mounting Bracket... 11 Other Operational Considerations... 13 Maintenance... 13 Laser Safety... 16 Warranty... 17 Certifications... 18 FCC Compliance Statement... 20 IC Warning... 21 2

Thank you for purchasing GoTemp. We are confident that you will be pleased with the quality and performance of this product. Please take a few moments to familiarize yourself with the operation, features, and benefits of this fine product. CAUTION! This product is not intended for medical use or use on humans Description The zippyyum GoTemp Model THB4002 is smart contactless thermometer featuring Bluetooth 4.0 Low Energy. GoTemp combines two precision thermometers: accurately calibrated noncontact infrared thermometer and a thermocouple port for penetration probe. The noncontact mode can be used for quick scans of a surface temperature, while the probe mode is used to accurately measure internal temperatures. GoTemp is a battery operated device and can be recharged via the standard micro USB connector from any computer or 5V charger. A K-type thermocouple connector is used to connect the insertion probe. The interface of the device is minimal as it includes an illuminated push button to provide ability to reset and give feedback about device status and a slide switch to turn ON and OFF 3

Features Contactless temperature measurement Laser pointer to indicate the measured location Accepts K-type thermocouples Rechargeable battery Interchangeable holders for iphone 5, 6, 6+, and universal bracket for use on all other phone models Distance to Spot The field of view (Distance to Spot) is the area or portion of food product that is being measured thermally. The distance of the infrared thermometer from the target determines the dimension of this area. The further away from the target, the larger is the area being measured. The ideal working range of GoTemp is between 25 mm and 300 mm (1 and 12inches). The laser pointer helps to indicate the measurement spot. To ensure accurate measurements, the measured spot must fill or exceed the field of view. Moving closer to the target produces more accurate measures 4

Reset To reset GoTemp, press and hold the button for 3 seconds. 5 orange blinks appear after the reset. Indicators GoTemp is equipped with two LEDs to indicate the device s state. Please note that Amber color appears if both red and green LEDs are lit simultaneously. Indicator reflects the device state and warns you if battery is getting low or there is not enough charge to power device. Green color indicates full battery, orange means that battery is low and red means battery is empty. Blinking light means the device is connected to a phone. You can always check the battery percentage and charging state on the phone s display. Refer to the below table for detailed indicator states 5

Battery Level Connected? Charging? LED State Not enough charge NO NO OFF Not enough charge NO YES Orange solid Not enough charge YES NO Red blink Not enough charge YES YES Orange blink Enough charge NO NO OFF Enough charge NO YES Green solid Enough charge YES NO Green blink Enough charge YES YES Green blink Bluetooth & Pairing GoTemp must be paired with smartphone before the first use. Every GoTemp device has a unique identifier printed on the back, it is known as MAC. The Mobile App will automatically connect to the available GoTemp if there is only one GoTemp found in the range, otherwise, a list will pop up for the user to select the device to be used. The names of available GoTemp devices show up as GOTEMP_XX, with XX denoting the last two digits of MAC. Once the correct GoTemp is chosen, the indicator starts blinking and a text box appears on mobile app to enter the PIN. Enter 123456 as pairing PIN. 6

Specifications Model: THB4002 Bluetooth Power: 0dBm Operating Conditions Parameter Storage Temperature Operating Temperature Humidity Charging Current Charging Voltage Battery Value -10-45 C (14-113 F) 10-40 C (50-104 F) 10-90% RH <100mA 5V Parameter Value Capacity 400 mah Voltage 3.7V Lifetime 360 hours Standby 16 hours measuring Laser Parameter Peak Wavelength Optical Power Value 650nm <1mW 7

Probe Temperature Parameter Conditions Value Measurement range Resolution Accuracy at room temperature Repeatability Response Time Infrared Temperature Object temperature: -10-120 C -10-120 C (14-250 F) 0.25 C (0.25 F) ±1 C (2 F) Within accuracy 1 second Parameter Conditions Value Measurement range -10-120 C (14-250 F) Resolution 0.1 C (0.1 F) Typical Measurement 25-300mm (1-12 ) Distance Distance to Spot 12:1 Accuracy at room Object temperature: ±0.5 C (2 F) temperature (25 C) 0-60 C Accuracy at room Object temperature: ±1 C (4 F) temperature (25 C) < 0 C or > 60 C Repeatability Within accuracy Response Time 1 second 8

AVOID STORING THE UNIT IN EXTREME TEMPERATURE CONDITIONS. DO NOT STORE INFRARED THERMOMETERS BELOW FREEZING TEMPERATURE OR WHERE THE RADIANT TEMPERATURE MAY EXCEED 48.9 C (120 F) Proper Application and Operation The IR thermometer only measures surface temperature, critical temperatures must be verified with an internal temperature probe. To take a spot temperature measurement, aim the sensor at the desired target and activate the unit. The spot size measured is indicated in section Distance to Spot. The IR thermometer cannot measure through transparent surfaces such as glass and plastic. It will measure the surface temperature of the glass, or plastic instead. Steam, dust, smoke and/or vapors can prevent accurate measurement by obstructing the unit s optics. Please refer to maintenance section for cleaning in case any of these conditions happened. Infrared thermometers are not designed for use in high humidity-condensing environments. For the most accurate temperature measurements, aim the infrared thermometer perpendicular to the target. If possible, the field of view should be an even, horizontal plane (the flattest surface of a food product being measured). Use Probe For Internal Temperature Mind The Measured Spot Remove Transparent Covers Before Measuring Keep Unit Clean Do Not Measure in High humidity Keep Device Perpendicular To Measured Surface 9

The IR thermometer is not recommended for use in measuring reflective surfaces such as stainless steel and/or aluminum wrapping. The temperature of a reflective object may be measured if the surface is coated with a matte material. The infrared emissivity of a target is a function of the reflective properties of its surface. GoTemp Emissivity is preset to 0.95 which is optimal for most Food Products. If the emissivity of the target material is questionable, determine its value by referring to the emissivity table. GoTemp emissivity can be changed from 0.1 to 1.0 in 0.01 steps, refer to instruction in the mobile app to modify emissivity. GoTemp is designed to work between 10 C and 40 C (50-104 F). In case a change in temperature happened like walking in/out of walk-in freezer, the unit must not be used for at least 15 minutes (preconditioned). Failure to precondition the unit may result in thermal shock and/or inaccurate measurements. GoTemp can display temperatures in Celsius or Fahrenheit, refer to instruction in the mobile app to change scale. Avoid Measuring Shiny Surfaces Most Food Products Do Not Require Change of Emissivity Precondition For 15 Minutes If Ambient Temperature Changed Select Desired Display Unit 10

Power Switch Power Switch located on the bottom of GoTemp is turned OFF to minimize battery drain. Use a small plastic pin to switch the power button ON before operation. Five orange blinks appear at power up. Make sure the LEDs are working, otherwise, plug charger and expect flashing orange light. Power button can be turned off if GoTemp is not used for long time, which will save battery and extend its life. Mounting Brackets Four mounting brackets are provided for iphone 5/5s, iphone 6, iphone 6+ and adjustable bracket for use on all other phones. After turning the switch ON, position the bracket and push it in the guiding grooves to snap in place. Push the bracket in opposite direction to remove. 11

12

Other Operational Considerations GoTemp is protected from the following: EMI (Electro Magnetic Interference) from induction heaters and microwave ovens Electrostatic discharge Should the unit become damaged, check the accuracy of the unit by performing the verification process recommended in this manual. If the unit is out of calibration, do not rely on it for critical temperature measurements. Contact a zippyyum for information Maintenance Field Verification of Accuracy GoTemp is pre-calibrated. However, their accuracy can be verified in the field by using the following simple procedure. It is suggested that the accuracy of the instrument be verified on a regular basis. For food applications, the IR thermometer accuracy should be verified at the relevant critical food temperatures [5 C (41 F); 60/71.1 C (140 /165 F)]. A two-point verification is recommended. Materials needed: 1. Aluminum container (beverage can). 2. Matte-black spray paint or matte-black self-adhering paper appliqué. Masking tape may also be used. 3. Temperature-standard thermometer. 13

Preparation: Prepare container by painting or applying the matte material to the outer surface. Verification Procedure: 1. Fill the aluminum container with refrigerated water, insert the temperature standard thermometer and allow the can and temperature-standard thermometer to come to equilibrium. 2. Take a reading with the IR thermometer. Do not exceed the spot size of the IR thermometer as indicated on the unit. 3. Compare the temperature reading of the IR unit with the temperature standard thermometer *. 4. Repeat this procedure using hot water. * If the temperature deviation exceeds accuracy limit, return the unit for repair. Preparation Verification 14

Cleaning Instructions To ensure an accurate temperature reading, the lens of the IR unit should be free of dirt, dust, moisture, fog, smoke and debris. To clean the lens, you would need two lint free cotton swabs. Moist a cotton swab and insert it in the aperture to scrub the deep lens then repeat the same using the dry cotton swab. To clean the unit itself, wipe it down with a moist cloth using water based mild detergent. Warning! Do not submerse the unit or wash in dishwasher 15

Laser Safety Laser pointer in GoTemp is FDA 21 CFR 1040.10, subchapter J compliant. Please refer to laser specifications in specification section Warning! 1. Avoid direct exposure of human eyes to laser light. Eye damage may result. 2. Never point the laser light at another person. 3. Keep the laser-equipped unit out of the reach of children. 4. Avoid indirect exposure via reflective surfaces, such as glass and mirrors. 16

Warranty ZippyYum LLC warrants that this product, at the time of its sale by ZippyYum, is free of defects in material and workmanship and component failures under normal and proper use for a period of one (1) year from date of delivery and applies worldwide. ZippyYum s only obligation is to correct such defects by repair or replacement, at its option, if within such one year period the product is returned prepaid. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose. ZippyYum is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. ZippyYum s liability on any claim for damages arising out of in connection with the manufacture, sales, installation delivery, or use of the product shall never exceed the purchase price of the product. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise. In line with ZippyYum s policy of continuous development ZippyYum reserves the right to alter any specifications without notice. 17

Certifications GoTemp conforms to the following standards: UL listed for UL2333 Standard For Safety - Infrared Thermometers UL EPH Classified for ANSI/NSF 2 standard for FCC CFR47 Part 15 Section 15.247:2014 Industry Canada RSS-247 European Union Directives 1999/5/EC - Radio & Telecommunications Terminal Equipment (R&TTE) Directive 2014/35/EU - Low Voltage (LVD) Directive 2014/30/EU - Electromagnetic Compatibility (EMC) Directive 2011/65/EU - EU Restriction of Hazardous Substances (RoHS) Directive 2012/19/EU - Waste Electrical and Electronic Equipment (WEEE) Directive ACME (Australia) Standards AS/NZS 4268:2012+ A1:2013 EN 61000-6-1:2007 EN 61000-6-3:2007 +A1:2011 EN 61000-3-2:2014 EN 61000-3-3:2013 18

INFRARED THERMOMETER E481655 FABRICATED FOOD SERVICE EQUIPMENT NSF/ANSI 2 SA44549 RCM Cert. No: POC16104019 Industry Canada Industrie Canada IC: 21861-THB4002 FCC ID:2AE6ATHB4002 19

FCC Compliance FCC Part 15.19 Warning Statement THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARM- FUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. FCC Part 15.21 Warning Statement NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIP- MENT. FCC Part 15.105 Warning Statement Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. 20

Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. RF warning statement The device has been evaluated to meet general RF exposure requirement. The device can beused in portable exposure condition without restriction. IC Warning This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. RF warning statement: The device has been evaluated to meet general RF exposure requirement. Le dispositif de a été évalués à répondre général RF exposition exigence. 21

ZippyYum LLC 275 Centennial Way, #105, Tustin, CA 92780 Phone: +1 (888) 636-7557 Fax: +1 (866) 434-0883 www.zippyyum.com www.mangoe.com 22