Standards Update Notice (SUN) Issued: January 9, 2017

Similar documents
Standards Update Notice (SUN) Issued: February 2, 2017

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 2, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 28, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 2, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 16, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: April 26, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 19, 2018

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Rules for Classification and Construction Additional Rules and Guidelines

INTERNATIONAL STANDARD

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

CERTIFICATION BULLETIN

This document is a preview generated by EVS

INTERNATIONAL STANDARD

CLASS POWER ENGINEER S CERTIFICATE

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

96TH GENERAL ASSEMBLY State of Illinois 2009 and 2010 SB1690

INTERNATIONAL STANDARD

DIVISION C ADMINISTRATIVE PROVISIONS

NFPA 72 Code Changes vs 2013

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

INTERNATIONAL STANDARD

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

DEPARTMENT OF TRADE AND INDUSTRY DEPARTEMENT VAN HANDEL EN NYWERHEID. NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008)

NEMA Applications Guide

NEW ENERGY IN THE BATTERY INFRASTRUCTURE

INTERNATIONAL STANDARD

FIFTH CLASS POWER ENGINEER S

INTERNATIONAL STANDARD

This is a preview - click here to buy the full publication ICS ISBN

INTERNATIONAL STANDARD

AS/NZS 3111:2009. Approval and test specification Miniature overcurrent circuitbreakers AS/NZS 3111:2009. Australian/New Zealand Standard

IE Code IE Competency Title Credit OAC Ref.

SOUTH AFRICAN NATIONAL STANDARD

Australian/New Zealand Standard

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018

INTERNATIONAL STANDARD NORME INTERNATIONALE

Certificate of Compliance

File E Project 97SC January 21, 1998 REPORT

ISO Safety of machinery Laser processing machines Part 1: General safety requirements

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

SHOP PRIMERS FOR CORROSION PROTECTION OF STEEL PLATES AND SECTIONS

INTERNATIONAL STANDARD

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 16: Sound system control and indicating equipment

INTERNATIONAL STANDARD

This document is a preview generated by EVS

TELECOMMUNICATION EQUIPMENT LOCATED IN THE VICINITY OF PROPOSED DISTRIBUTION HV EARTHS

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Procedure for the Approval of New Fire Detection and Alarm Technologies

Medical devices and electromagnetic compatibility. Addressing the requirements of IEC , 4 th Edition

INTERNATIONAL STANDARD

Request for Qualifications For Administration of the 2016 Summer Sprout Program

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

This document is a preview generated by EVS

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Chapter 2: Definitions

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

AS/NZS :2016. Explosive atmospheres AS/NZS :2016. Part 7: Equipment protection by increased safety e. Australian/New Zealand Standard

A Review of America s First Step Towards the Harmonization of Portable Battery Standards: UL 62133

ISO INTERNATIONAL STANDARD. Safety of machinery Laser processing machines Part 1: General safety requirements

N.J.A.C. 5: A. NEW JERSEY ADMINISTRATIVE CODE Copyright (c) 2016 by the New Jersey Office of Administrative Law

INTERNATIONAL STANDARD

Substations and high voltage installations exceeding 1 kv a.c.

FIRE DEPARTMENT PERMIT GUIDELINES

National Certificate in Fire Detection and Alarm Systems (Level 4) Level 4

RULES OF THE TENNESSEE ALARM SYSTEMS CONTRACTORS BOARD CHAPTER GENERAL PROVISIONS TABLE OF CONTENTS

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION

Quick Touch Pendant User Guide

An Urgent Bulletin from CSA Group

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Denmark SECRETARY:

INTERNATIONAL STANDARD

Are there any new or emerging trends in technology that will impact the scope and work activities of the TC? Please describe briefly.

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

UNIFIED FACILITIES GUIDE SPECIFICATIONS

INTERNATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD

Australian Standard. Fire detection and alarm systems. Part 6: Carbon monoxide fire detectors using electro-chemical cells

SECTION AUTOMATIC TRANSFER SWITCHES

In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a

AS/NZS IEC :2013

Transcription:

Standard Information This SUN contains new/revised requirements from updates dated September 2, 2016 and October 7, 2016 Standard Number: UL 1795 Standard Name: Hydromassage Bathtubs Standard Edition and Issue Date: 5 th Edition Dated September 2, 2016 Date of Revision: October 7, 2016 Date of Previous Revision of Standard: 4 th Edition Revised January 7, 2015 Effective Date of New/Revised Requirements Effective Date (see Schedule below): October 6, 2017 Impact, Overview, Fees and Action Required Impact Statement: A review of all Listing Reports is necessary to determine which products comply with new/revised requirements and which products will require re-evaluation. NOTE: Effective immediately, this revised standard will be exclusively used for evaluation of new products unless the Applicant requests in writing that current requirements be used along with their understanding that their listings will be withdrawn on Effective Date noted above, unless the product is found to comply with new/revised requirements. This new edition to UL 1795, the Standard for Hyrdromassage Bathtubs, includes the following changes: Revise requirements for electronic circuits Allow the use of UL 840 to evaluate clearance and creepage distances Update requirements for switches Update requirements for button or coin cell batteries of lithium technologies Specific details of new/revised requirements are found in table If the applicable requirements noted in the table are not described in your report(s), these requirements will need to be confirmed as met and added to your report(s) such as markings, instructions, test results, etc. (as required). Client Action Required: Information To assist our Engineer with review of your Listing Reports, please submit technical information in response to the new/revised paragraphs noted in the attached or explain why these new/revised requirements do not apply to your product (s). Current Listings Not Active? Please immediately identify any current Listing Reports or products that are no longer active and should be removed from our records. We will do this at no charge as long as Intertek is notified in writing prior to the review of your reports. Standards Update Notice MY/KM SUN Template 02012016 Page 1 of 5

Description of New/Revised Technical Requirements -- -- New/Revised requirements from Update dated September 2, 2016 19 Info Circuits 19.1 Info General 19.1.1 A reliability investigation is required for limited-energy circuits, safety circuits, or where single-mode component faults result in a risk of fire, electric shock, or injury to persons. Circuits and controls shall comply with the requirements of this standard and those in either Supplement SA, SB or SC. 19.1.2 When safety circuits are investigated, consideration shall be given to the need for additional testing, depending on the circuit construction and the intended function. All circuits shall be evaluated to determine that single-mode component faults will not result in a risk of fire, electric shock, casualty hazards or loss of a Safety Critical Function. 19.4 Circuits that perform Safety Critical Functions 19.4.1 A temperature-regulating control, a temperature-limiting control, and a dry fire control are considered to be safety circuits. Any function involved in the control, protection, and monitoring of safety-related attributes of a hydromassage bathtub whereby a loss/malfunction of its functionality would represent an unacceptable risk of fire, electric shock, or casualty hazards would be considered a Safety Critical Function. See Table 19.1 for the most common Safety Critical Functions anticipated by this standard. Standards Update Notice MY/KM SUN Template 02012016 Page 2 of 5

New table added; Safety Critical Functions Table 19.1 19.4.2 Function a Hazard Location of parameters and tests Motor running overload Risk of fire or electric shock Section 30 protection Motor locked rotor protection Risk of fire or electric shock Section 30 Motor short circuit protection Risk of fire or electric shock Section 30 Temperature regulating control Hyperthermia Section 40 Temperature limiting control Scalding Section 41.2 Water-Flow Controls (dry-fire Risk of fire, electric shock, or Section 41.3 protection) scalding a Functions specified in the table represent the common safety critical circuit functions of hydromassage bathtubs. It is not intended to represent all possible safety critical functions. Any function involved in the control, protection, and monitoring of safety-related attributes of a hydromassage bathtub whereby a loss/malfunction of its functionality would represent an unacceptable risk of fire, electric shock, or casualty hazards would be considered a Safety Critical Function. The on-off function of the overall hydromassage bathtub would be considered a Safety Critical Function only if a mandatory off period is necessary for the unit to comply with the Temperature Test. Electronic circuits that manage a Safety Critical Function shall be: 19.4.3 a) Reliable as defined as being able to maintain the Safety Critical Function in the event of single defined component faults; and 23 Info b) Not susceptible to electromagnetic environmental stresses encountered in the anticipated environments of the appliance. New Section added; Clearance and Creepage Distances As an alternative approach to the spacing requirements specified in Spacings, Section 22, and other than as noted in 23.2, clearances and creepage distances may be evaluated in accordance with the requirements in the Standard for Insulation Coordination Including Clearances and Creepage Distances for Electrical Equipment, UL 840, as described in 23.3. 38 Info Switches, Receptacles, and Controls 38.1 Info General 38.1.12 Switches that comply with the Standard for Switches for Appliances Part 1: General Requirements, UL 61058-1, shall be rated as specified in 38.1.13 38.1.15. Standards Update Notice MY/KM SUN Template 02012016 Page 3 of 5

Power switches shall be rated as follows: a) For a voltage not less than the rated voltage of the appliance; b) For a current not less than the rated current of the appliance; c) For Continuous Duty; d) With respect to load: 38.1.13 1) Switches for motor-operated appliances: for resistance and motor load in accordance with the Standard for Switches for Appliances Part 1: General Requirements, UL 61058-1, or the Outline for Particular Requirements for Switches for Tools, UL 6059, if the switch would encounter this load in normal use; or 2) Switches may be regarded as switches for a declared specific load in accordance with the UL 61058-1, or UL 6059 and may be classified based upon the load conditions encountered in the appliance under normal load. e) For ac if the appliance is rated for ac; 38.1.14 f) For dc if the appliance is rated for dc. Ratings and load classifications for switches other than power switches shall be based on the conditions encountered in the appliance under normal load. Switches shall also be rated with respect to endurance as follows: a) Power switches: 6000 cycles; b) Power switches provided with series electronics shall be subject to an additional 1000 cycles of operation with the electronics bypassed; 38.1.15 c) Switches other than power switches, such as speed selector switches, that may be switched under electrical load: 1000 cycles; d) The following non-power switches are not required to be rated for endurance: 1) Switches not intended for operation without electrical load, and which can be operated only with the aid of a tool or are interlocked so that they cannot be operated under electrical load; or 2) Switches for 20 ma load as classified in the Standard for Switches for Appliances Part 1: General Requirements, UL 61058-1. Standards Update Notice MY/KM SUN Template 02012016 Page 4 of 5

SUPPLEMENT SA SUPPLEMENT SB Info UL 60335-1 BASED REQUIREMENTS FOR THE EVALUATION OF ELECTRONIC CIRCUITS These requirements provide alternate requirements for the investigation of electronic controls and other circuits used in appliances covered by this standard (see standard for section details). CONTROLS EVALUATED TO UL 60730-1 AND ITS PART 2 S This new section includes new construction requirements for Temperature-Regulating Controls, Temperature-Limiting Controls, and Pressure-Sensitive Controls (see standard for section details). -- -- New/Revised requirements from Update dated October 7, 2016 7.5 Button or coin cell batteries of lithium technologies The battery compartment of an appliance or any accessory, such as a wireless control, incorporating one or more coin cell batteries of lithium technologies shall comply with the Standard for Products Incorporating Button or Coin Cell Batteries of Lithium Technologies, UL 4200A, if the appliance or any accessory: 7.5.1 a) Is intended for use with one or more single cell batteries having a diameter of 32 mm (1.25 in) maximum with a diameter greater than its height; and b) The appliance is intended for household use. Exception: UL 4200A is not applicable to appliances and accessories intended for use where the battery is not intended to be replaced and is not referenced in instructions and markings. CUSTOMERS PLEASE NOTE: This Table and column Verdict can be used in determining how your current or future production is or will be in compliance with new/revised requirements. Standards Update Notice MY/KM SUN Template 02012016 Page 5 of 5