HEAT RECOVERY AIR HANDLING UNIT

Similar documents
SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

Turbo. Service Instructions

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

HEAT RECOVERY VENTILATOR

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

HEAT RECOVERY AIR HANDLING UNITS

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

DUCT COOLERS KWK KFK OPERATION MANUAL. KWK_KFK_v2(4)_EN.indd :35:29

Wind. Service instruction

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

USER S MANUAL. VKP Series INLINE FAN

CENTRIFUGAL FANS user's manual. model VENTS VK.

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

AXIAL FANS USER S MANUAL

Aero. Service Instructions

Centrifugal inline fans

Calm. Service Instructions

AIR HANDLING UNIT WITH HEAT RECOVERY

CENTRIFUGAL CEILING EXTRACT FAN

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

CENTRIFUGAL CEILING EXTRACT FAN

Installation manual Mini Comfort 50 S/L 07/ V EN

INTELLIGENT AXIAL FAN user's manual

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

Air handling unit. BlauAir RH USER S MANUAL

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit

KOMFORT EC DB Suspended heat recovery air handling units

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

USER S OPERATION MANUAL HL-RD 2000 E EC HL-RD 3000 E ЕС

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

USER'S MANUAL INLINE CENTRIFUGAL FANS IN SOUND-INSULATED CASING VS, VS EC SERIES

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

Axial intelligent fan USER S MANUAL

USER S MANUAL DN-2. Drain pump

USER'S MANUAL PS

AXIAL DOMESTIC FANS. User manual LARUS LIBELLA FENESO CYCNUS CICONUS SIGILA SIGILA MOTION

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit

AXIAL FANS user's manual. model Quiet

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

White - Non Illuminated Art no White - Cool White LED Art no.32600

Turbo Inline Fan, White - Non Illuminated Art no.33500

Series VENTS VUT R WH ЕС

KKKKKKKCOOKER HOOD INSTRUCTION MANUAL

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Multifunction. Vax model number:

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

CONTENTS QUICK REFERENCE GUIDE PROGRAMME CHART

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

PORTABLE AIR CONDITIONER

Cooker Hood LA-72-CAN.

CANOPY RANGEHOOD. instruction manual V3FC60SS & V3FC90SS 12 MONTH WARRANTY

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

ART cm Island Curved Glass

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Lo-Carbon Quadra Centrifugal Fan

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

SELF-PRIMING JET PUMPS

Operating instructions

Range Hoods. General Manual. For Models: IVN900X, IVN900N, IVCC900X, IVCG900, IVSG900

GLEB Kitchen exhaust fan

Tools required. Pencil Drill Screwdriver Dowel (2 pcs.) Screws (2 pcs.)

RX550i Electric Pressure Washer

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE BOOKLET PROGRAMME CHART

GEH9026G Cooker Hood

ISCG90SS _03 ISCG90SS

OPERATION AND MONTAGE MANUAL ROOF FANS

K-Star International Group Inc. K-Star Electronic Appliance Inc. Toll Free:(800)

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE PROGRAMME CHART BOOKLET

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

Lo-Carbon Quadra SELV

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

VEX250H with rotary heat exchanger and EXact control system

Installation manual. Tumble dryers T4130. Compass Control

IMPORTANT INSTRUCTIONS READ & SAVE

USER'S MANUAL. Micra 150 HEAT RECOVERY UNIT

OPERATION AND MONTAGE MANUAL ROOF FANS

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

Transcription:

HEAT RECOVERY AIR HANDLING UNIT OPERATION MANUAL KOMFORT_L v2(2)_en.indd 1 07.08.2015 15:0:44

CONTENTS Introduction General Safety regulations Transportation and storage regulations Manufacturer's warranty 4 Design 4 Operation logic 4 Delivery set 5 Technical data 6 Mounting 7 Condensate drainage 8 Connection to power mains 9 Unit control 9 Technical maintenance 10 Troubleshooting 11 Acceptance certificate 11 Connection certificate 11 Warranty card 2 KOMFORT_L v2(2)_en.indd 2 07.08.2015 15:0:45

BLAUBERG Ventilatoren GmbH Company is happy to offer your attention a heat recovery air handling unit. INTRODUCTION The present operation manual contains a technical description, technical data sheets, operation and mounting guidelines, safety precautions and warnings for safe and correct operation of the unit. Read carefully and understand the operation manual, especially the safety requirements, before the unit mounting and start up. Keep the operation manual available as long as you use the unit. GENERAL The heat recovery air handling unit is designed for efficient and energy saving ventilation of domestic and public premises. The unit is not a ready to use product but a component part of central air conditioning and ventilation network. The unit is available for Ø 125 or 15 mm air ducts depending on the model. The unit is designed for indoor application with the ambient temperature ranging from +1 C up to +50 C and relative humidity up to 80 %. Hazardous parts access and water ingress protection rating: unit motors - IP 44; assembled unit connected to air ducts - IP 22. The unit design is regularly improved, so some models can slightly differ from those ones described in this operation manual. SAFETY REGULATIONS All operations related to the unit electrical connections, servicing and repair works are allowed only after the unit is disconnected from power supply. The unit is rated as a Class I electrical appliance. All mounting and servicing operations are allowed by duly qualified personnel. Please, follow the safety regulations and working instructions (DIN EN 50 110, IEC 64). Make sure the impeller and the casing are not damaged before connecting the unit to power supply. The casing internals must be free of any foreign objects which can damage the impeller blades or the motor. The unit maintenance and repair is allowed only after power cut-off and full stop of the rotating parts. Misuse of the unit or any unauthorized modifications are not allowed. The unit is designed for connection to AC single-phase power mains in compliance with the «Technical data» section. The unit is rated for continuous operation. Take steps to prevent ingress of smoke, carbon monoxide and other combustion products into the room through open chimney flues or other fire-protection devices. Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting. The maximum permitted pressure difference per living units is 4 Pa. The transported air must not contain any dust or other solid impurities, sticky substances or fibrous materials. The unit is not rated for operation in a flammable or explosive medium. Fulfil the operation manual requirements to ensure a trouble-free and long service life of the unit. The unit complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU- Directives on Electromagnetic Compatibility. We hereby declare that the unit complies with the essential protection requirements of Electromagnetic Council Directive 2004/108/EC, 89/6/EEC and Low Voltage Directive 2006/95/EC, 7/2/EEC and CE-marking Directive 9/68/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility, which relate to electrical appliances used in set voltage classes. The Manufacturer hereby warrants normal operation of the unit over the period of two years from the retail purchase date provided observance of the installation and operation regulations. In case of a failure due to a manufacturing fault during the warranty period the consumer has the right to exchange it. The replacement is offered by the Seller. In case of no confirmation of the purchase date, the warranty period shall be calculated from the manufacturing date. The MANUFACTURER is not responsible for any damage resulting from any misuse of or gross mechanical interference with the unit. The MANUFACTURER is not responsible for the damages resulted due to the use of third party equipment or to third party equipment. MANUFACTURER S WARRANTY The unit complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU- Directives on Electromagnetic Compatibility. We hereby declare that the unit complies with the essential protection requirements of Electromagnetic Council Directive 2004/108/EC, 89/6/EEC and Low Voltage Directive 2006/95/EC, 7/2/EEC and CE-marking Directive 9/68/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility, which relate to electrical appliances used in set voltage classes. The Manufacturer hereby warrants normal operation of the unit over the period of two years from the retail purchase date provided observance of the installation and operation regulations. In case of a failure due to a manufacturing fault during the warranty period the consumer has the right to exchange it. The replacement is offered by the Seller. In case of no confirmation of the purchase date, the warranty period shall be calculated from the manufacturing date. The MANUFACTURER is not responsible for any damage resulting from any misuse of or gross mechanical interference with the unit. The MANUFACTURER is not responsible for the damages resulted due to the use of third party equipment or to third party equipment. TRANSPORTATION AND STORAGE REGULATIONS! WARNING The unit is not allowed for use by children and persons with reduced physical, mental or sensory capacities, without proper practical experience or expertise, unless they are controlled or instructed on the product operation by the person(s) responsible for their safety. Supervise the children and do not let them play with the unit. WARNING Do not dispose in domestic waste. The unit contains in part materials that can be recycled and in part substances that should not end up as domestic waste. Dispose of the unit once it has reached the end of its working life according to the regulations valid in your country. KOMFORT_L v2(2)_en.indd 07.08.2015 15:0:45

0 1 2 0 1 2 DESIGN The casing is made of aluminium profile and double-skinned aluzinc panels, internally filled with 20 mm mineral wool layer for heat- and soundinsulation. The casing has mounting brackets with anti-vibration rubber mounts for easy installation. The spigots are located at the sides of the unit and are equipped with rubber seals for airtight connection to the air ducts. The hinged side panels ensure easy access to the internals for service works including cleaning, filter replacement, etc. The unit is equipped with external rotor AC-motors and centrifugal doubleinlet impellers with forward curved blades. The motors are equipped with integrated overheating protection with automatic restart and ball bearings for a long service life. Connect the unit to power mains through the terminal block located in the terminal box on the side panel of the casing. The unit incorporates a plate cross-flow aluminium heat exchanger. The drain pan under the heat exchanger block is used for condensate collection and drainage. The unit is equipped with a built-in heat exchanger protection system to prevent its freezing in the cold season. If the heat exchanger freezing becomes imminent a thermostat relay interrupts the supply fan circuit. After the supply fan shuts down automatically the heat exchanger is warmed up by the stream of warm air from the exhaust fan. After that the supply fan is turned on and the unit reverts to the normal operation mode. To set the thermostat operation temperature turn the control knob until reaching the desired value. The recommended operating value for the thermostat relay in the absence of a duct heater in the air supply part of the ventilation system is +5 C. Two built-in G4 cassette filters provide high-end air purification. Optionally F7 intake filter may be mounted. The unit incorporates an external CDP-/5 four-position speed switch that enables setting low, medium, maximum speed and turning the unit off. The switch mounted on the side panel allows to switch off the supply fan if necessary. 50 / L500 / L50 / L600 1200 / L2200 Extract filter Heat exchanger Intake filter Extract filter Control unit Intake filter EXTRACT AIR INTAKE AIR Speed switch INTAKE AIR EXTRACT AIR SUPPLY AIR EXHAUST AIR Terminal box Speed switch Thermostat EXHAUST AIR SUPPLY AIR Terminal box Drain pan Exhaust fan Supply fan Control unit Thermostat Drain pan Supply fan Heat exchanger Exhaust fan Fig. 1. Unit design and operating logic OPERATING LOGIC Cold fresh air from outside flows through the heat exchanger and is moved to the room with the supply fan. Warm extract air is extracted from the room with the exhaust fan and is moved through the heat exchanger, where it transfers its heat energy to the intake air. After that it is exhausted outside. Heat energy of warm and humid extract air is transferred to the cold fresh air. The air flows are fully separated while flowing through the heat exchanger. Heat recovery minimizes heat losses caused by traditional window ventilation and saves energy. In summer the heat exchanger performs reverse and transfers cold from the cooled extract air to the warm fresh air. This contributes to better performance of the air conditioner in ventilated premises. In summer, when the indoor and outdoor temperature difference is low heat recovery is not reasonable. In this case the heat exchanger can be temporary replaced with a summer block for warm seasons. Available upon separate order. DELIVERY SET Air handling unit - 1 item Operation manual - 1 item Speed switch - 1 item Packing box - 1 item! ATTENTION Make sure the unit has no visible transport damages while accepting the goods. Check the ordered and the delivered goods for compliance. 4 KOMFORT_L v2(2)_en.indd 4 07.08.2015 15:0:46

TECHNICAL DATA Table 1. Technical data Parameters KOMFORT L50 KOMFORT L500 KOMFORT L50 KOMFORT L600 KOMFORT L1200 KOMFORT L2200 Voltage [V] 1~ 20 / 50-60 Hz 1~ 20 / 50 Hz Power [kw] 0,26 0, 0, 0,9 0,82 1, Current [A] 1,2 1,2 1,2 1,72,6 5,68 1~ 20 / 50-60 Hz Max. air capacity [m /h] 50 500 50 600 1200 2200 R.p.m. 1150 1100 1100 150 1850 1150 Sound pressure level at m distance [db(a)] 24-45 28-47 28-47 2-48 60 65 Transported air temperature [ C] Casing material from -25 up to +55 from -25 up to +50 aluzinc from -25 up to +55 from -25 up to +40 Insulation 25 mm mineral wool 50 mm mineral wool Extract filter cassette G4 Intake filter cassette F7 cassette G4 (F7)* Connected air duct diameter [mm] 125 150 160 200 250 15 Weight [kg] 45 49 49 54 85 96 Heat recovery efficiency [%] up to 78 up to 88 up to 85 up to 88 up to 87 Heat exchanger type Heat exchanger material cross-flow aluminium Table 2. Overall dimensions Dimensions [mm] Model D B B1 B2 B H H1 H2 L L1 50 124 416 00 54 207 60 20 148 722 768 500 149 416 00 54 207 60 20 148 722 768 50 159 416 00 54 207 60 20 148 722 768 600 199 416 00 54 207 60 20 148 722 768 1200 248 548 496 60 21 794 290 200 802 850 2200 1 846 796 25 588 968 60 246 1000 1050 Fig. 2. Overall dimensions Table. Accessories Model Replaceable G4 cassette filter Replaceable F7 cassette filter Summer block 50 SB-L50 500 SB-L500-600 FP-L50-600 G4 FP-L50-600 F7 50 SB-L500-600 600 SB-L500-600 1200 FP-L1200 G4 FP-L1200 F7 SB-L1200 2200 FP-L2200 G4 FP-L2200 F7 SB-L2200 5 KOMFORT_L v2(2)_en.indd 5 07.08.2015 15:0:46

MOUNTING WARNING! Safety precautions: The unit must be mounted to a rigid and stable structure. The unit must be suspended using anchor bolts. Make sure that the base structure is capable of sustaining the unit weight. The unit mounting is allowed only after power cut-off and full stop of the rotating parts. Restrictions: Do not operate the unit beyond the determined temperatures, in aggressive and in explosive medias. Do not connect the clothes dryer or other similar equipment to the ventilation system. Do not use the unit for air/dust mixture handling. The unit is designed for indoor mounting. The unit has versatile mounting possibilities and may be installed on the floor, suspended to the ceiling or fixed to the wall. The unit is suitable for mounting in technical, service premises as well as living and lounge areas. Install straight air ducts on both sides of the unit to minimize aerodynamic resistance caused by air flow turbulence, the minimum air duct section length is equal to 1 time air duct diameter on the inlet side and time air duct diameters on the outlet side. While planning the ductwork layout avoid too long air duct sections, numerous bends and reducers because it may reduce air flow. The mounted air ducts must not be deformed. Provide airtight connection of the air ducts to the unit spigots and fittings. While mounting consider the need to ensure sufficient service access to the unit. The unit mounting position must provide condensate drainage and access to the terminal box for electric connection and access to the service panel for maintenance and filter replacement. In case of insufficient length or no air ducts cover the unit spigots with a protecting grille or any other protecting device with maximum mesh width 12.5 mm to prevent ingress of foreign objects inside the unit and to prevent contact with unit fans. Unit mounting on a horizontal plane Fix the unit on a rigid and stable horizontal plane. Unit mounting on a horizontal plane min. 80 mm Fig. 4. Suspended mounting of the unit Suspended mounting CDP-/5 speed Unit switch mounting mounting on (Fig. a horizontal 5): plane 1) Remove the speed switch knob. Nut Washer Vibration absorbing rubber Nut and lock nut 2) Use a screwdriver to carefully undo the clips on the front panel of the speed switch and remove the panel. ) Route the cable in the wall to the speed switch installation site. 4) Connect the wires to the speed switch and fix the back panel to the wall through the mounting holes. 5) Install the front panel and the control knob of the speed switch. 65 Fig.. Unit mounting on a horizontal plane Suspended mounting Prior to starting mounting make sure the mounting surface has sufficient load capacity matching the unit weight. Otherwise reinforce the installation place with beams. The unit must be rigidly fixed! Loose fixation of the unit may result in noise and vibration generation. The unit is suspended to the ceiling with four M8 anchor bolts, the matching dowels, nuts and washers. Fig. 5. Speed switch mounting 6 KOMFORT_L v2(2)_en.indd 6 07.08.2015 15:0:47

CONDENSATE DRAINAGE Drain pipe B A % U-trap Sewage system Fig. 6. Condensate drainage The drain pan is equipped with a drain pipe for condensate removal outside the unit. Connect the drain pipe, the U-trap (not included into the delivery set) and a sewage system with drain hoses. While laying the hoses provide the slope downward min %. Fill the system with water prior to connecting it to power supply. The U-trap must always be filled with water to maintain free flow of condensate. The condensate drain system is suitable for indoor frost-free application with the ambient temperature above 0 C! If the expected ambient temperature is below 0 C provide heating for the drain system. Table 4. Recommended dimensions of the U-trap Minimum dimensions [mm] Model A B 50 500 50 600 1200 120 60 2200 200 110 WARNING! In case of several units mounting connect each unit to an individual U-trap. Direct condensate drainage with no connection to the drain system is not allowed. 7 KOMFORT_L v2(2)_en.indd 7 07.08.2015 15:0:48

CONNECTION TO POWER MAINS! WARNING Read the service instruction prior to any electric installations. Connection of the unit to power mains is allowed by a qualified electrician only. The rated electrical parameters are stated on the rating plate. Any tampering with the internal connections is prohibited and will void the warranty. Connect the unit only to power mains with valid electric standards. Follow the respective electric standards, safety rules (DIN VDE 0100), TAB der EVUs. The house cabling system must be equipped with a magnetic trip automatic switch at the external input. The contact gap on all poles must be at least mm (VDE 0700 T1 7.12.2 / EN 605-1). The automatic switch trip current must be not below the rated current consumption (see Table 1). Enable quick access to an automatic switch installation place. The unit is rated for connection to single-phase AC power mains according to the Table 1 «Technical data». The electric connections must be performed with insulated, durable and heat-resistant conductors (cables, wires) with a matching cross section. The above cross section is for reference only. The applicable cable must be selected in consideration of the maximum wire temperature depending on the wire and insulation type, the maximum current, the lead wire length and its installation method. Use copper wires only. The unit must be grounded in compliance with the valid electrical standards of the user country! The unit connection must be consistent with the Wiring diagram and the terminal designations given on Fig. 7. Connect all the control and supply cables in compliance with the terminal marking and polarity! The rating plate with a terminal designation is placed inside of the terminal box. Table 5. Recommended currents of the of automatic switch Model Rated current of the automatic switch [A] 50 500 1,6 50 600 2 1200 6 2200 10 Cut power supply to the unit off by turning the automatic electric switch QF to OFF position prior to any operations. Take steps to prevent activation of the automatic switch before finishing all the operations. QF 50 / L500 / L50 /L600 1200 / L2200 L ~20 V N 50-60 Hz PE QF Terminal box X1 L N 2 1 Control unit X4 C B 1 2 CDP-/5 speed switch C B C 2 B 1 Control unit X4 1 2 C B 1200 ~20 V / 50 Hz 2200 ~20 V / 50-60 Hz L N PE QF L N Fig. 7. Wiring diagram 8 KOMFORT_L v2(2)_en.indd 8 07.08.2015 15:0:48

UNIT CONTROL The step control of the unit air flow is performed with the speed switch. Make sure to install the switch in a convenient location. The units are equipped with the CDP /5 speed controller. It is factoryconnected to the unit terminal block in compliance with the Wiring diagram on page 7. To engage the desired speed turn the speed control knob clockwise into one of the three positions available (Fig. 8): OFF 1 2 O Speed 1; Speed 2; Speed. To switch off the unit turn the speed control knob counterclockwise until reaching the «0» (left) position. Fig. 8. Speed switch control TECHNICAL MAINTENANCE! WARNING Cut power supply to the unit off by turning the automatic electric switch QF to OFF position prior to any maintenance operations. Take steps to prevent activation of the automatic switch before finishing all the operations. QF Regular technical supervision and maintenance of the unit are required to ensure the product long service life and non-stop operation. Disconnect the unit from power supply prior to any maintenance operations. WARNING! Consider the unit sharp edges! Fulfil maintenance operations in work gloves! Maintenance operations of the unit are required -4 times per year. The unit technical maintenance includes regular cleaning and other works: 1. Filter maintenance (-4 times per year). Dirty filters increase air resistance and decrease supply air volume. Clean the filters with a vacuum cleaner or flush those with water. After two consecutive cleanings the filter must be replaced. Install dry filters only! Contact a local distributor to purchase the filters stated above in the «Technical data» section. Dirty filters are not considered as a warranty case! Replace humid and mouldy filters immediately. To remove the filters proceed as follows: Make sure the unit is disconnected from power mains. Unlatch and open the service panel. Remove the dirty filters from the unit and install new or cleaned filters. 2. Heat exchanger maintenance (once a year). The heat exchanger must be regularly cleaned to maintain high heat recovery efficiency even in case of the regular filter cleaning. To clean the heat exchanger pull it out, flush the heat exchanger with warm detergent solution. After cleaning install the dry heat exchanger back to the unit. Sequence of heat exchanger removal: Make sure the unit is disconnected from power mains. Unlatch and open the service panel. Remove the filters from the unit. If necessary install new or cleaned filters. Remove the dirty heat exchanger from the unit. After technical maintenance install the dry heat exchanger back to the unit. 4. Condensate drain system maintenance (once per year). The condensate drainage (drain line) may get clogged by dirt and dust particles contained in the exhaust air. Check the drain line operation by filling the drain pan under the unit with water, clean the U-trap and the drain line, if necessary. 5. Technical maintenance of the supply grille (twice a year). Check the supply grille and remove foreign objects to maintain free air intake. 6. Air ducts maintenance (once in 5 years). Even regular fulfilling of all the prescribed above maintenance operations may not completely prevent dirt accumulation in the air ducts which reduces the unit capacity. Duct maintenance means regular cleaning or replacement. 7. Exhaust grilles and intake diffusers maintenance (if required). Remove the exhaust grilles and the intake diffusers and flush those with warm detergent solution. Check the ductworks connections periodically!. Fan maintenance (once a year). The regular filter cleaning may not completely prevent the dust ingress into the unit, which results in the unit performance decrease. Clean the fan with a soft cloth or a brush. Cleaning with water, abrasive detergents, sharp object or chemicals is not allowed. 9 KOMFORT_L v2(2)_en.indd 9 07.08.2015 15:0:49

TROUBLESHOOTING Fault Possible reason Troubleshooting The fans do not operate Automatic switch tripping Low air flow Noise, vibration Condensate leakage No power supply or wrong connection to power mains. The motor is jammed, the impeller blades are soiled. Short circuit in power grid. Too low set speed. The filters and the fans are soiled, the heat exchanger is soiled. The air dampers, the supply diffusers or the exhaust grilles are closed or soiled. The impeller is soiled. The screw connection is loose. No flexible anti-vibration connectors. The drain system is clogged, damaged or wrong installed. Connect the unit to power supply. Troubleshoot the connection error. Remove the motor jam, clean the impeller blades. Turn the unit off and contact the unit Seller for troubleshooting. Set higher speed. Clean or replace the filters, clean the fans and the heat exchanger. Open and clean the air dampers, the supply diffusers, the exhaust grilles to ensure free air flow. Clean the impeller. Tighten the screws. Install the flexible anti-vibration connectors. Clean the condensate drain system. Check the drain hose slope. Make sure the U-trap is filled with water and the drain system is frost-protected. 10 KOMFORT_L v2(2)_en.indd 10 07.08.2015 15:0:49

ACCEPTANCE CERTIFICATE The air handling unit with heat recovery 50 500 50 600 1200 2200 is recognized as serviceable. The unit complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU-Directives on Electromagnetic Compatibility. We hereby declare that the unit complies with the essential protection requirements of Electromagnetic Council Directive 2004/108/EC, 89/6/EEC and Low Voltage Directive 2006/95/EC, 7/2/EEC and CE-marking Directive 9/68/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility, which relate to electrical appliances used in set voltage classes. This certificate is issued following test carried out on samples of the product referred to above. Approval mark Manufacturing date CONNECTION CERTIFICATE Heat recovery air handling unit 50 500 50 600 1200 2200 is connected to power mains in compliance with the operation manual requirements by the professional: Company: Expert s Full Name Date Signature WARRANTY CARD 50 500 50 600 1200 2200 SELLER PURCHASE DATE REPRESENTATIVE IN EU BLAUBERG Ventilatoren GmbH Aidenbachstr. 52a, D-8179 München, Deutschland 11 KOMFORT_L v2(2)_en.indd 11 07.08.2015 15:0:49

v.2(2) / EN KOMFORT_L v2(2)_en.indd 12 07.08.2015 15:0:49