HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

Similar documents
USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

Air handling unit. BlauAir RH USER S MANUAL

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL DN-2. Drain pump

HEAT RECOVERY VENTILATOR

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit

CENTRIFUGAL CEILING EXTRACT FAN

CENTRIFUGAL CEILING EXTRACT FAN

Centrifugal inline fans

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

USER S MANUAL. VKP Series INLINE FAN

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

AIR HANDLING UNIT WITH HEAT RECOVERY

AXIAL FANS USER S MANUAL

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Axial intelligent fan USER S MANUAL

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15

HEAT RECOVERY AIR HANDLING UNITS

Installation manual Mini Comfort 50 S/L 07/ V EN

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

DUCT COOLERS KWK KFK OPERATION MANUAL. KWK_KFK_v2(4)_EN.indd :35:29

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

AXIAL FANS user's manual. model Quiet

CENTRIFUGAL FANS user's manual. model VENTS VK.

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

USER S OPERATION MANUAL HL-RD 2000 E EC HL-RD 3000 E ЕС

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

USER'S MANUAL INLINE CENTRIFUGAL FANS IN SOUND-INSULATED CASING VS, VS EC SERIES

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

INTELLIGENT AXIAL FAN user's manual

KOMFORT EC DB Suspended heat recovery air handling units

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Wind. Service instruction

USER'S MANUAL PS

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Calm. Service Instructions

Tools required. Pencil Drill Screwdriver Dowel (2 pcs.) Screws (2 pcs.)

Turbo. Service Instructions

AXIAL DOMESTIC FANS. User manual LARUS LIBELLA FENESO CYCNUS CICONUS SIGILA SIGILA MOTION

Sensor Control Panel

USER S MANUAL UET CONTROL UNIT FOR THE AIR HEATING UNIT WITH ELECTRIC HEATER AOE SERIES

USER'S MANUAL. Micra 150 HEAT RECOVERY UNIT

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

GDDEM10 DEHUMIDIFIER

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

Aero. Service Instructions

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

Operation Manual. Automatic Control System for Air Supply Ventilation Unit with Hydronic Coil Heat Exchanger

30-pint Dehumidifier User Guide

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

Bar Fridge USER MANUAL MB46W

Cooker Hood LA-72-CAN.

RCM-77. Instruction Manual. G-Series Cooler. Manual is for the following model: RCM-77-N23EB. U.S. Patent No. 8,215,125 RECHARGEABLE COLD MERCHANDISER

Series VENTS VUT R WH ЕС

Up to 60 Pint Commercial Grade DEHUMIDIFIER

DAIKIN ROOM AIR CONDITIONER. Operation Manual

Meaco 10L small home dehumidifier Instructional Manual

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D

BLAUAIR AUTOMATIC CONTROL SYSTEM

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

KKKKKKKCOOKER HOOD INSTRUCTION MANUAL

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

MeacoDry ABC Range Dehumidifiers

OPERATION AND MONTAGE MANUAL ROOF FANS

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

PORTABLE AIR CONDITIONER (LOCAL)

Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug. Instruction Manual.

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

User Manual. Dishwasher ZDM17301SA ZDM17301WA

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

General safety precautions English

Washing Machine. User manual WW9*K5*****/WW8*K5*****/WW7*K5***** Untitled :17:40

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

51AKS I S O OWNER S MANUAL

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Transcription:

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT S S11 Series SB S11 Series SB -E S11 Series SB -E S11 Series EN OPERATION MANUAL

CONTENTS Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5 Design and operating logic... 6 Mounting and set-up... 8 Condensate drainage... 10 Connection to power mains... 11 Unit control... 12 Maintenance... 12 Troubleshooting... 13 Storage and transportation rules... 13 Manufacturer s warranty... 14 Acceptance certificate... 15 Seller information... 15 Connection certificate... 15 Warranty card... 15 The user s manual consisting of the technical details, operating instructions and technical specification applies to the installation and mounting of the heat recovery air handling unit series SB S11 and S S11 and of the heat and humidity recovery air handling unit series SB -E S11 and S -E S11 (hereinafter the unit as mentioned in the Safety Requirements and Manufacturer s Warranty sections as well as in warnings and information blocks). SAFETY REQUIREMENTS Read the user s manual carefully prior to installing and operating the unit. Fulfil the user s manual requirements as well as the provisions of all the applicable local and national construction, electrical and technical norms and standards. The warnings contained in the user s manual must be considered most seriously since they contain vital personal safety information. Failure to follow the rules and safety precautions noted in this user s manual may result in an injury or unit damage. After a careful reading of the manual, keep it for the entire service life of the unit. While transferring the unit control the User s manual must be turned over to the receiving operator. Symbol legend: WARNING! DO NOT! 2

UNIT MOUNTING AND OPERATION SAFETY PRECAUTIONS Disconnect the unit from power mains prior to any installation operations. Unpack the unit with care. Do not lay the power cable of the unit in close proximity to heating equipment. While installing the unit follow the safety regulations specific to the use of electric tools. Do not use damaged equipment or cables when connecting the unit to power mains. Do not operate the unit outside the temperature range stated in the user's manual. Do not operate the unit in aggressive or explosive environments. Do not touch the unit controls with wet hands. Do not carry out the installation and maintenance operations with wet hands. Do not wash the unit with water. Protect the electric parts of the unit against ingress of water. Do not allow children to operate the unit. Disconnect the unit from power mains prior to any technical maintenance. Do not store any explosive or highly flammable substances in close proximity to the unit. When the unit generates unusual sounds, odour or emits smoke disconnect it from power supply and contact the Seller. Do not open the unit during operation. Do not direct the air flow produced by the unit towards open flame or ignition sources. Do not block the air duct when the unit is switched on. In case of continuous operation of the unit periodically check the security of mounting. Do not sit on the unit and avoid placing foreign objects on it. Use the unit only for its intended purpose. THE PRODUCT MUST BE COLLECTED SEPARATELY AT THE END OF SERVICE LIFE. DO NOT DISPOSE OF AS UNSORTED MUNICIPAL WASTE. 3

PURPOSE The unit is an energy saving unit based on heat recovery technology and is one of the energy saving components used in the buildings and premises. The unit is a component part and is not designed for stand-alone operation. The unit is designed to provide permanent controlled air exchange by means of mechanical ventilation in houses, offices, hotels, cafés, meeting halls and other mechanically ventilated premises as well as utilization of extract air heat energy to warm up supply purified air. THE UNIT MAY NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED PHYSICAL, MENTAL OR SENSORY CAPACITIES, OR LACKING THE APPROPRIATE TRAINING. THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED PERSONNEL AFTER THE APPROPRIATE BRIEFING. THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORIZED ACCESS BY UNATTENDED CHILDREN. Transported air must not contain any flammable or explosive mixtures, evaporation of chemicals, coarse dust, soot and oil particles, sticky substances, fibrous materials, pathogens or any other harmful substances. DELIVERY SET Unit User's manual Control panel user's manual Control panel Outdoor temperature sensor Drain pipe Packing box Number 1 pc. 1 pc. 1 pc. 1 pc. 1 pc. 1 pc. DESIGNATION KEY S1B160-E S11 Unit type Motor type electronically commutated Spigot orientation S vertical spigot orientation Casing modification Extra components _ no components available B bypass Air capacity [m 3 /h] _ ventilation unit with heat recovery E ventilation unit with heat and humidity recovery Control panel type 4

The unit is designed for indoor application with the ambient temperature ranging from +1 C (+33.8 F) up to +40 C (+104 F) and relative humidity up to 80 %. Hazardous parts access and water ingress protection rating: IP44 for the unit motors, IP22 for the assembled unit connected to the air ducts. The unit design is regularly improved, so some models can slightly differ from those ones described in this manual. Technical data S160 S11 S1 160 S11 SB160 S11 S1B160 S11 SB350 S11 S1B350 S11 S2B350 S11 SB550 S11 Unit voltage [V / Hz] 120/60 Max. unit power [W] 51 51 51 51 170 170 170 333 370 Max. unit current [A] 0.4 0.4 0.4 0.4 1.3 1.3 1.3 2.3 2.5 Max. air capacity [m 3 /h] 180 180 180 180 415 415 415 750 625 RPM 3770 3770 3770 3770 3200 3200 3200 3230 3230 Sound pressure level at 3 m distance [db(a)] 24 22 24 22 28 28 30 28 28 Transported air temperature [ C] from -25 C (-13 F) up to +50 C (122 F) Casing material painted steel Insulation Extract filter Supply filter Heat exchanger type Heat exchanger material Connected air duct diameter [mm] 20 mm (4/5 ) mineral wool Ø 125 (Ø 5 ) 40 mm (1 3/5 ) mineral wool Ø 125 (Ø 5 ) 20 mm (4/5 ) mineral wool Ø 125 (Ø 5 ) 40 mm (1 3/5 ) mineral wool 40 mm (1 3/5 ) mineral wool G4 F7 counter-flow 40 mm (1 3/5 ) mineral wool polystyrene/enthalpy membrane Ø 125 (Ø 5 ) Ø 160 (Ø 6 1/3 ) Ø 160 (Ø 6 1/3 ) 20 mm (4/5 ) mineral wool Ø 160 (Ø 6 1/3 ) TECHNICAL DATA 40 mm (1 3/5 ) mineral wool Ø 200 (Ø 8 ) S2B550 S11 Heat recovery efficiency [%] 88-98/80-94 88-98/80-94 88-98/80-94 88-98/80-94 80-89/76-89 84-94/74-90 85-93/76-90 85-88/72-92 73-88/71-92 Weight [kg] 42 47 44 49 66 55 53 83 62 20 mm (4/5 ) mineral wool Ø 200 (Ø 8 ) B B1 L2 ØD L1 H1 H ØD1 L Dimensions [mm] Model Ø D Ø D1 B B1 H H1 L L1 L2 S160 S11 124 (4 4/5 ) 18 (5/7 ) 348 (13 5/7 ) 330 (13 ) 650 (1 1/5 ) 550 (21 2/3 ) 600 (23 3/5 ) 388 (15 2/7 ) 143 (5 3/5 ) S1 160 S11 124 (4 4/5 ) 18 (5/7 ) 388 (15 2/7 ) 370 (14 3/5 ) 680 (26 6/8 ) 590 (23 2/9 ) 640 (25 2/9 ) 388 (15 2/7 ) 143 (5 3/5 ) SB160 S11 124 (4 4/5 ) 18 (5/7 ) 348 (13 5/7 ) 330 (13 ) 690 (27 1/6 ) 580 (22 5/6 ) 600 (23 3/5 ) 388 (15 2/7 ) 143 (5 3/5 ) S1B160 S11 124 (4 4/5 ) 18 (5/7 ) 385 (15 1/6 ) 370 (14 3/5 ) 690 (27 1/6 ) 620 (24 3/7 ) 640 (25 2/9 ) 388 (15 2/7 ) 143 (5 3/5 ) SB350 S11 159 (6 2/7 ) 18 (5/7 ) 610 (24 ) 592 (23 2/6 ) 758 (29 4/5 ) 675 (26 2/3 ) 730 (28 3/4 ) 426 (16 3/5 ) 230 (9 ) S1B350 S11 159 (6 2/7 ) 18 (5/7 ) 488 (19 2/9 ) 475 (18 6/9 ) 760 (30 ) 673 (26 2/4 ) 70 (28 3/4 ) 426 (16 3/5 ) 190 (7 2/5 ) S2B350 S11 159 (6 2/7 ) 18 (5/7 ) 465 (18 2/7 ) 451 (17 5/6 ) 737 (29 ) 634 (25 ) 735 (29 ) 426 (16 3/5 ) 190 (7 2/5 ) SB550 S11 198 (7 4/5 ) 18 (5/7 ) 741 (29 1/6 ) 722 (25 2/5 ) 758 (29 4/5 ) 675 (26 3/5 ) 828 (32 3/5 ) 493 (19 2/5 ) 284 (11 1/5 ) S2B550 S11 198 (7 4/5 ) 18 (5/7 ) 566 (22 2/7 ) 550 (21 2/3 ) 737 (29 ) 634 (25 ) 810 (31 4/5 ) 493 (19 2/5 ) 259 (10 15 ) 5

DESIGN AND FUNCTIONING Outdoor temperature sensor Electric lead-ins Control unit Control panel Inspection door Service panel *Bypass damper Supply air temperature sensor Counter-flow heat exchanger Extract filter Supply filter Freeze protection temperature sensor Supply fan Extract fan Condensate drain pan Drain pipe The unit is equipped with a removable front service panel for maintenance and repair operations. The removable service panel design enables to change the service side location. The control unit is accessible for mounting and wiring operations through the inspection door on top of the unit. For accessing the control unit remove the service panel after mounting and wiring operations. The control unit is accessible for service operations through the swivel mounting plate. The power cable and ground cable are connected to the control unit via the cable entries. The difference between the supply and extract air flow temperature leads to condensate generation. Condensate is collected in the drain pan and is removed outside through the drain pipe. The bypass damper is open or closed depending on operation mode of the unit. *The bypass damper is available for the models. Accessories for the unit are available on a separate order: FS1 humidity sensor. The unit with the installed humidity sensor maintains a set indoor humidity point. As the extract air humidity rises above the set point, the unit fans switch to the maximum speed. As the humidity drops down below the set point the unit fans return to the previous mode. The humidity sensor must be installed and connected by a service technician on site, page 8. EVH duct heater for supply air pre-heating. The heater maintains the air temperature in the intake air duct at a point that prevents freezing of the heat exchanger. A control system regulates heater operation. Mounting and connection of the heater, see page 8. UNIT OPERATION MODES Heat recovery Warm extract air from the room flows into the unit and is cleaned in the extract filter. Then the air is moved through the heat exchanger and is exhausted outside with the extract fan. Cold fresh air from outside flows into the unit, where it is cleaned in the supply filter. Then the air flows through the heat exchanger and is moved to the room with the supply fan. Supply air is heated in the heat exchanger by transferring the heat energy of warm and humid extract air to the cold fresh air. The air flows are fully separated while flowing through the heat exchanger. Heat recovery minimizes heat losses, which reduces the cost of space heating in the cold season. EXTRACT AIR SUPPLY AIR EXHAUST AIR INTAKE AIR Service side view 6

Summer cooling mode The bypass damper is opened, the extract air that is removed from the premises bypasses the heat exchanger. The air stream temperature remains constant. INTAKE AIR EXHAUST AIR SUPPLY AIR EXTRACT AIR Backside view Defrosting mode The defrosting mode is designed for heat exchanger freezing protection and is activated on feedback from the freeze protection temperature sensor. The temperature sensor is fixed to the inner surface of the extract air duct. Defrosting procedure is possible in two ways: Shutdown of the supply fan. For details, please refer to the user s manual for the control panel. See section Engineering menu, Extra options, Supply fan shutdown. Intake air pre-heating with the duct pre-heater EVH (accessory). For details, please refer to the user s manual for the control panel. See section Engineering menu, Extra options, Heating control. EXTRACT AIR SUPPLY AIR EXHAUST AIR INTAKE AIR INTAKE AIR SUPPLY AIR EXHAUST AIR EXTRACT AIR Service side view Backside view 7

MOUNTING AND SET-UP THE UNIT MUST BE MOUNTED BY A QUALIFIED EXPERT ONLY, PROPERLY TRAINED AND HAVING THE REQUIRED TOOLS AND MATERIALS. FS1 HUMIDITY SENSOR MOUNTING AND CONNECTION The FS1 humidity sensor is not included in the scope of delivery and should be ordered separately. The humidity sensor must be installed prior to unit mounting. Install the humidity sensor through the extract spigot into the mount located in the extract section of the casing. Then connect the humidity sensor contact socket to the respective contact socket on the control unit, refer the wiring diagram. Humidity sensor FS1 Contact socket for connection to the control unit Humidity sensor contact socket Exhaust air duct Fastener EVH HEATER MOUNTING AND CONNECTION The EVH pre-heater is not included in the delivery and is available on a separate order. The heater is rated for connection to single-phase AC 230 V/50 (60) Hz. The heater is designed for mounting in the air duct connected with the intake spigot of the unit. The heater and the air handling unit must be connected via the cable with the DB-9M connectors through the DB-9F connectors on the unit and on the heater. SERVICE SIDE CHANGE Make sure of the correct unit service side selection. Unit mounting position should enable free excess to the service panel for maintenance and service operations. EXTRACT AIR SUPPLY AIR EXHAUST AIR INTAKE AIR INTAKE AIR EXHAUST AIR SUPPLY AIR EXTRACT AIR Left-handed modification Right-handed modification 8

Service side change for unit mounting: 1 2 3 4 9

UNIT MOUNTING To attain the best performance of the unit and to minimise turbulence-induced air pressure losses while mounting connect the straight air duct section to the spigots on both sides of the unit. Minimum straight air duct length: equal to 1 air duct diameter on intake air spigot. equal to 3 air duct diameter on supply air spigot. If the air ducts are not connected or the connected air ducts are too short cover the spigots with a protecting grille or other protecting device with mesh width not more than 12.5 mm (3/6 ) to prevent uncontrollable access to the fans. While installing the unit ensure convenient access for subsequent maintenance and repair. The unit must be mounted on a plane wall. Mounting the unit to an uneven surface can lead to the unit casing distortion and operation disturbance. Unit wall mounting Fasteners for wall-mounting are not included into delivery set and should be ordered separately. While selecting fasteners consider the material of the mounting surface as well as the unit weight. For details, refer Technical Data. Fasteners for unit mounting should be selected by Customer Service technician. Fix the wall-mounted hook at the required height and hang the unit on the hook. Unit floor mounting Install the unit on the pre-set floor supports, minimum 150 mm (6 ) height, to ensure sufficient access for the drain pipe connection to the U-trap and for condensate drain system mounting. min 150 mm (6 ) WALL-MOUNTED CONTROL PANEL INSTALLATION Fixing methods for control panel wall mounting: wall surface mounting and wall flush mounting. Example of wall flush mounting using a junction box is shown in the control panel user s manual. The junction box and the mounting kit must be purchased separately. CONDENSATE DRAINAGE Condensate drainage is required for the unit series SB S11 and S S11. The hole for the drain pipe is at the bottom of the unit. Remove the plug from the hole, open the service panel and install the drain pipe from the delivery set into the hole, then connect the drain pipe to the sewage system using the SG-32 U-trap kit (available upon separate order). The pipe slope downwards must be at least 3. DRAIN PIPE min 3 U-TRAP DRAIN HOSE SEWAGE SYSTEM 10

CONNECTION TO POWER MAINS DISCONNECT THE UNIT FROM POWER SUPPLY PRIOR TO ANY ELECTRIC INSTALLATION OPERATIONS. INSTALLATION SHALL ONLY BE PERFORMED BY A PROFESSIONAL ELECTRICIAN QUALIFIED FOR UNASSISTED OPERATIONS WITH ELECTRICAL INSTALLATIONS UP TO 1000 V AFTER CAREFUL STUDY OF THE PRESENT USER S MANUAL. THE RATED ELECTRICAL PARAMETERS ARE STATED ON THE RATING PLATE. ANY TAMPERING WITH THE INTERNAL CONNECTIONS IS PROHIBITED AND WILL VOID THE WARRANTY. The unit is rated for connection to a single-phase ac 230 V / 50 60 Hz. The unit shall be connected to power supply by means of insulated, durable and thermal-resistant cords (cable, wires). Connect the unit to power mains using the pre-wired power cord with the Euro Plug XP. Connection is made through the external automatic circuit breaker with magnetic trip integrated into the fixed wiring system. The rated current of the circuit breaker must not be below the unit current consumption, refer to the Technical data. The external circuit breaker position must ensure unhampered access for emergency shutdown of the unit. Connect the cables to the control unit using the electric lead-ins on the top of the unit and make the electric connections through the terminal block X1, located in the control unit, in compliance with the external connections wiring diagram. Access to the control board of the control unit External connection wiring diagram Х1 17 16 15 14 13 12 11 10 Out Gnd E+ A B Gnd +12V no 9 c 8 no 7 6 5 c L L N N L 4 L 3 PE 2 N 1 L ELECTRIC SHOCK HAZARD! Out Gnd E+ t 0C TE1 A B Gnd +12V P1 ССU (no-contact) 2 1 2 1 2 1 L N L N SM2 SM1 PK1 Power input 230 VAC Design. Description Type Wire** CCU* DX cooler N0 2x0,75 mm 2 (5/64 x1/86 ) SM1* Supply air damper actuator LF230 SM2* Exhaust air damper actuator LF230 PK1* Contact from fire alarm panel N0 P1 Control panel TE1 Outdoor temperature sensor 2x0,75 mm 2 (5/64 x1/86 ) 2x0,75 mm 2 (5/64 x1/86 ) 2x0,75 mm 2 (5/64 x1/86 ) * is not included in the delivery. ** Maximum connecting cable length is 20 m! WARNING! The EVH pre-heater must be connected to power supply prior to connection of the air handling unit! If the electric heater is not available in the air handling unit while its connection to power supply, the control panel displays DI1 and DI3 errors. To troubleshoot the errors disconnect the unit from power supply, connect the heater and turn the unit on. 11

UNIT CONTROL The unit is operated with the control panel. For detailed information, read the control panel user s manual. MAINTENANCE DISCONNECT THE UNIT FROM POWER MAINS PRIOR TO ANY MAINTENANCE OPERATIONS. Maintenance operations of the unit are required 3 4 times per year. Maintenance includes regular cleaning and the following operations: 1. Filter maintenance (3 4 times per year). Dirty filters increase air resistance in the system and reduce supply air volume. The filters require cleaning not less than 3 4 times per year. Vacuum cleaning is allowed. Replace the filters after two consecutive cleanings. Contact the product Seller to purchase new filters. 2. Heat exchanger maintenance (once per year). Some dust may accumulate on the heat exchanger block even in case of regular maintenance of the filters. To maintain the high heat exchange efficiency, regular cleaning is required. To clean the heat exchanger(s) pull it(them) out of the unit and flush it(them) with warm detergent solution. After cleaning install the dry heat exchanger(s) back to the unit. 3. Fan maintenance (once per year). Even in case of regular maintenance of the filters, some dust may accumulate inside the fans and reduce the fan performance and supply air flow. Clean the fans with a soft brush or cloth. No water and abrasive detergent, sharp objects or solvents are allowed for cleaning to prevent the impeller damage. 4. Condensate drainage maintenance (once per year). The drain pipes may get clogged with the extracted particles. Pour some water inside the drain pan to check the pipe for clogging. Clean the U-trap and the drain pipe if required. 5. Ductwork system maintenance (once in 5 years). Even if you follow all the listed maintenance guidelines, some dust can accumulate inside the air ducts and reduce the unit performance. Duct maintenance means regular cleaning or replacement. 6. Control unit maintenance (if necessary). The control unit maintenance must be performed by an expert qualified for unassisted operations with electrical installations with the voltage up to 1000 V after careful reading of the user s manual. Access to the control unit for maintenance operations: 1 2 3 12

TROUBLESHOOTING Problem Possible reasons Troubleshooting The fan(s) do(es) not get started. Low air flow. Noise, vibration. Water leakage. DI1 or DI3 errors are displayed on the control panel. No power supply to the air handling unit. Contaminated filters, fans or the heat exchanger. Contaminated or damaged ventilation system. Contaminated impeller. Loose screw connection in the fan or the casing. Contaminated, damaged or wrong mounted drainage system. Missing heater during activated heating mode. Make sure the power supply line is connected correctly, otherwise troubleshoot a connection error. Clean or replace the filters; clean the fan(s) and the heat exchanger. Clean the ventilation system components. Replace damaged components. Clean the impellers. Tighten the mounting screws of the fans or the casing against stop. Clean the drainage system. Check the drain line slope angle. Make sure that the U-trap is filled with water and the drain pipes are frost protected. Deactivate the heating mode to troubleshoot the alarm indicators. If the errors are still displayed on the control panel, please refer to the product Seller for troubleshooting. STORAGE AND TRANSPORTATION RULES Store the unit in the manufacturer s original packaging box in a dry closed ventilated premise with temperature range from +5 С (+41 F) to +40 С (+104 F). Storage environment must not contain aggressive vapours and chemical mixtures provoking corrosion, insulation, and sealing deformation. Use suitable hoist machinery for handling and storage operations to prevent possible damage to the unit. Follow the handling requirements applicable for the particular type of cargo. The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechanical damage. The unit can be transported only in the working position. Avoid sharp blows, scratches, or rough handling during loading and unloading. Prior to the initial power-up after transportation at low temperatures allow the unit to warm up at room temperature for at least 3-4 hours. 13

MANUFACTURER S WARRANTY The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby declare that the product complies with the provisions of Electromagnetic Council Directive 2014/30/EU, Low Voltage Directive 2014/35/EU and CE-marking Directive 93/68/EEC. This certificate is issued following test carried out on samples of the product referred to above. The manufacturer hereby warrants normal operation of the unit for 24 months after the retail sale date provided the user's observance of the transportation, storage, installation, and operation regulations. Should any malfunctions occur in the course of the unit operation through the Manufacturer's fault during the guaranteed period of operation, the user is entitled to get all the faults eliminated by the manufacturer by means of warranty repair at the factory free of charge. The warranty repair includes work specific to elimination of faults in the unit operation to ensure its intended use by the user within the guaranteed period of operation. The faults are eliminated by means of replacement or repair of the unit components or a specific part of such unit component. The warranty repair does not include: routine technical maintenance unit installation/dismantling unit setup To benefit from warranty repair, the user must provide the unit, the user's manual with the purchase date stamp, and the payment paperwork certifying the purchase. The unit model must comply with the one stated in the user s manual. Contact the Seller for warranty service. The manufacturer s warranty does not apply to the following cases: User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismounted by the user. Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user's manual. User s failure to ensure timely technical maintenance of the unit. External damage to the unit casing (excluding external modifications as required for installation) and internal components caused by the user. Redesign or engineering changes to the unit. Replacement and use of any assemblies, parts and components not approved by the manufacturer. Unit misuse. Violation of the unit installation regulations by the user. Violation of the unit control regulations by the user. Unit connection to power mains with a voltage different from the one stated in the user's manual. Unit breakdown due to voltage surges in power mains. Discretionary repair of the unit by the user. Unit repair by any persons without the manufacturer s authorization. Expiration of the unit warranty period. Violation of the unit transportation regulations by the user. Violation of the unit storage regulations by the user. Wrongful actions against the unit committed by third parties. Unit breakdown due to circumstances of insuperable force (fire, flood, earthquake, war, hostilities of any kind, blockades). Missing seals if provided by the user s manual. Failure to submit the user s manual with the unit purchase date stamp. Missing payment paperwork certifying the unit purchase. DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE ANY MAINTENANCE OPERATIONS! USER S WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON PRESENTATION OF THE UNIT, THE PAYMENT DOCUMENT AND THE USER S MANUAL WITH THE PURCHASE DATE STAMP. 14

CERTIFICATE OF ACCEPTANCE Unit Type Model Serial Number Manufacture Date Single-room reversible energy recovery ventilator S S11 We hereby declare that the product complies with the protection requirements of Electromagnetic Council Directive 2014/30/EU, Low Voltage Directive 2014/35/EU and CE-marking Directive 93/68/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. This certificate is issued following the test on the samples of the product referred to above. Quality Inspector s Stamp SELLER INFORMATION Seller Address Phone Number E-mail Purchase Date This is to certify acceptance of the complete unit delivery with the user s manual. The warranty terms are acknowledged and accepted. Customer s Signature Seller s Stamp INSTALLATION CERTIFICATE The single-room reversible energy regeneration ventilator S S11 has been connected to power mains pursuant to the requirements stated in the present user s manual. Company Name Address Phone Number Installation Technician s Full Name Installation Date: Signature The unit has been installed in accordance with the provisions of all applicable local and national construction, electrical, and technical codes and standards. The unit operates normally as intended by the manufacturer. Installation Company Stamp Signature: WARRANTY CARD Unit Type Model Serial Number Manufacture Date Purchase Date Warranty Period Seller Single-room reversible energy recovery ventilator S S11 Seller 15

Komfort(EC)_SB v5(6)_en