KMART Corrective Action Plan

Similar documents
Personal Care Appliances in Sweden

Personal Care Appliances in Thailand

HC1089 HC Koninklijke Philips N.V. All rights reserved 保留所有权利 (25/9/2017) > 75% 循环再造纸

说明书 澳大利亚 ARTUSI KH90A-F1N160 薛孝田 印刷说明 : 2.. 此印刷品自 起开始实施 3. 此印刷品最终成品大小为 A4 纸一半大小 4. 此印刷品黑白印刷 5. 此印刷品要求字迹清晰 不能有漏印 错印 模糊现象 客户名称 产品型号 会签 型号经理

Shaking Peltier Device

Portable Ionizing Air Gun PIA 型离子风枪 型号 : 94101

Rosemount 214C Sensor. Quick Start Guide , Rev BB March 2019

Kitchen Exhaust Duct (KED) Requirements

Prospects and challenges for sustainable urbanization in China

Question? 有疑问? Contact Philips 请联系飞利浦 FC6132 FC6130

A New Generation of Active Intrusion Detection System for Physical Protection

CW-5000/ 5200 INDUSTRIAL CHILLER USER MANUAL

TECHNICAL PRODUCT DATASHEET

PolyBox TM. Edition II. Operation Manual

Collaborative efforts for sustainable campus 可持续校园建设多方协作机制的初探

New Town Development and Practices

LEVEL SENSORS & FLOAT SWITCHES

qianlong garden restoration project 乾隆花园修复工程

SUNSTAR 单片机专用电路 TEL: FAX: Features 6 Digit 6 Function LCD Alarm Watch with RGB LE

美的吸尘器 使用说明书 VACUUM CLEANER OPERATION INSTRUCTIONS MANUAL C5 PRO (C5-L121D) 使用产品前请仔细阅读本说明书 并请妥善保管

所有的资料是按最新出版的产品资料编写而成遥科勒公司保留任何时候不经通知即可改变产品特性尧包装或产品可供类型的权利遥 说明书包括重要的安装内容袁请把这些资料交给用户阅读遥

Work Report of Chinese Steering Commi.ee of Landscape Architecture Educa8on

New Rural Planning Guidelines in the Chengdu Plain: The Case of Tianfu New Area

矿用电缆 矿 用 电 缆 江苏亨通电力电缆有限公司

YVP110 Advanced Valve Positioner. Please use the attached sheets for the pages listed below in the following manuals. IM 21B04C01-01E (10th)

EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters

Register your product and get support at 在以下网站注册并获得支持

BT9290. English. 1 Make sure the appliance is switched off and the laser guide is in off position.

TSI FMS Particle Monitoring Applications TSI FMS 在线粒子监控系统的应用. 2008, TSI Incorporated

Senab Interior established on the Bund introducing Scandinavian design and new ways to organize the office

PE Series Jaw Crusher P E

Gas Pipeline Locating Leak detection and Safety Assessment

践行里约 +20 决议, 示范新型城镇化 : 国际人居环境范例新城倡议

Consumer Appliances in Germany

BUREAU VERITAS GREATER CHINA 必维国际检验集团 大中华区 CRANE SERVICES 起重机服务

Beijing Urban Design Studio Summer 2008

Retailing in Romania. Customer Service Hotline: Page 1 of 23

Premium Desoldering station with Electric Pump Ref. DIS-D

MultiTemp IV Thermostatic Circulator

SOLARBOX Models 1500e RH and 3000eRH Accelerated xenon light fastness and weathering test chambers

EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters

2016 Koninklijke Philips N.V. All rights reserved 保留所有权利 (12/2016) > 75% 循环再造纸 BT9290. >75% recycled paper >75% papier recyclé

EJX / EJA-E series. For the description on the applicable page of users manual as shown in the item 1, please use revised information as shown in 2.

Always there to help you

Jiangbei New District, Nanjing ISOCARP Urban Planning Advisory Team Report

丹麦,Fuglsang 美术馆 / Tony Fretton Architects

Preparation. Name of Each Part. Safety Precautions (Be sure to always follow these precautions) ECLEAR MIST. HCE-HU03 Series. Turning the power on

亚太地区世界遗产培训与研究中心 ( 上海 ) 简讯 World Heritage Institute of Training and Research - Asia and Pacific, Shanghai

DC MOTOR FAN COIL UNIT 直驅無刷电机风机盤管

安装使用说明书. 维格一体化智能座便器 305mm/400mm 坑距 VOGUE INTELLIGENT INTEGRATED TOILET305mm/400mm RI 20127T-M-WK/20128T-M-WK

TRANSPORTATION EXISTING 交通现状

LEC TF55207W(CE-BCD275WM-SQ) 重量 (g) WEIGHT. 比例 scale 第页 NO. OF SHEETS

PREVENT ALL INJURIES IN THE KITCHEN. GO HOME SAFE AND HEALTHY.

Dr. Qiaoling Luo. Publications

User Manual. OCTAVIUS Detector 729 (T10040) and Detector Interface 4000 (T16039)

WAT E R S O U R C E H E AT P U M P S

Ethical Audit Report

Plant Safety 沼气厂安全. Raphael Thies and Dr Katharina Backes

Award-winning and absolutely new, Very stacks, swivels, and flexes far beyond ordinary seating to inject comfort and life into any space.

Sino-Singapore Tianjin Eco-city: A Model Sustainable City. Presentation for Australian Mission 1 March 2011

COMPARATIVE ANALYSIS AND PEDESTRIAN SIMULATION EVALUATION ON EMERGENCY EVACUATION TEST METHODS FOR URBAN RAIL TRANSIT STATIONS

Hot Air Station without Extractor desk Ref. JTSE-QA

Projects. Studio. Index. Office 2 Retail 28 Education and research 44 Residential 58 Mixed use 80 Arts and installations 100

The Home Depot Quality System Audit. * Example Report * North America Latin America

RAS-DX18HDK/RAC-DX18HDK

XJTLU 2017 INTERNATIONAL SYMPOSIUM 国际学术研讨会 TRANSPORT AND URBAN TRANSFORMATION IN CONTEMPORARY CHINA 当代中国的交通与城乡转型发展. Date and Location 会议时间与地点

Retrospect And Prospect Of Master Land Use Plan In China

English (original instructions) 2 中文 ( 简体 ) 7 繁體中文 11 한국어 15. Copyright DeWALT

Boiler Safety Technical Supervision Administration Regulation

The Professional Laundry Experience

Technical Code for Engineering of Security and Protection System

Urban Models for the 21st Century

Hitachi Highly. Spezifikation Manual

"Three Preventions" System Design Based On Single-Chip Microcomputer SCM Control Jiaxiong Wen

RECENTLY, multicarrier modulation techniques, such

Contents. Precision Lead-free Reflow Oven. Model: AT-R3028

GreenUp Lowbay G2 BY288P. Lucia Liu Indoor Segment, PLP Growth Market Feb. 2016

Rosemount 848T High Density Temperature Measurement Family

A TOUCH OF INSPIRATION FOR MY NICE HOME. Housing & Development Board SAFE RENOVATION WITHOUT COMPROMISING BUILDING SAFETY

RTKL 谨在此向中国客户呈献本系列宣传册 本丛书一套四册, 涵盖内容广泛, 不仅向您展示 RTKL 过去辉煌的历史, 更力图展现我们对未来的卓越见解 我们的每件作品都富于灵动性和高品质, 在此呈献的仅仅是我们宏大作品库中的极小部分

WARNING/CAUTION DESCRIPTION OF COMPONENTS FUNCTION EXPLANATION OPERATION INSTRUCTIONS CONTINUOUS DRAINAGE CAUTIONS MAINTENANCE/EMERGENCY

地址 : 北京市朝阳区建国门外外交公寓 7 号楼 1 单元 101 号 电话 : / 传真 :

Rainwater Harvesting Techniques in Syrian Desert (Badia Basin)

Model 685B1001A10. Electronic Vibration Switch. Installation and Operating Manual

A Study of the Improvement of Planning Systems for Land Use Control in Agricultural Heritage Sites

Catering Service System Based on Environmental Design A Design Practice On Shengming Farm. Zhang Zhao Interior Design

R-S32EPH R-S32EPHL

Service Manual. Solar Direct Drive Vaccine Refrigerator / Freezer. Model :HTC-40/110; HTCD-90 Pictures :

IMPORTANT: Read carefully before assembly and use Techtronic Floor Care Technology Limited. All Rights Reserved.

FRENCH EXHIBITORS 法国展商

Characteristics of nitrogen, phosphorus and potassium absorption and optimum fertilization in Sugarcane Liuqiang ZHOU, Hongwei TAN

News Clipping. : Jul 18, 2016 (Monday) : FoodWaste Lean and Green Label Scheme Launching Ceremony. 黃錦星指政府已聯絡業界冀善用小蠔灣廚餘廠 Jul 18, 2016 CR

CONTENTS. I Description II Specification III Structure IV Mounting and Wiring V Application VI Troubleshooting...

Fire Protection with High Pressure Water Mist in the Tobacco Warehouse

Installation Instructions for the MICRO SWITCH VPX Series Valve Position Indicator for Hazardous Locations

Living Space Sensor Touchscreen Covers SXWSCDXSELXX (Touchscreen Display) SXWSCDPSELXX (Touchscreen Display with Occupancy Sensor)

compact Bagless Cyclonic Vacuum Cleaner IMPORTANT: Read carefully before assembly and use.

TeMA. Vol.10 n.2 August 2017 METHODS, TOOLS AND BEST PRACTICES TO INCREASE THE CAPACITY OF URBAN SYSTEMS TO ADAPT TO NATURALAND MAN-MADE CHANGES

TeMA is realized by CAB - Center for Libraries at Federico II University of Naples using Open Journal System

Transcription:

KMART Corrective Action Plan Report No.: A4578873 Vendor Code: V001842 Factory Code: F004469 Vendor Name (English): Fun Jewellery And Fashion Accessories PTY Ltd Vendor Name (Local Language): Not provided Factory Name (English): Dongguan Fenghe Plastic & Silk Flowers Products Factory Factory Name (Local Language): 东莞桥头枫和塑胶丝花制品厂 Factory Address (Local Language): 中国广东省东莞市桥头镇石水口村岭厦银海路 36 号 Auditor Company: Intertek Testing Services Shenzhen Ltd. Auditor Name(s): Ryan Zhou Audit Type: Initial Audit Renewal Audit Follow-up Audit Annual Audit Reinstate Audit Remediation Audit Audit : From: 21/11/2016 09:00:00 AM To: 21/11/2016 05:00:00 PM To Factory: The hard copy of this cap left to the factory is a preliminary version of the finding summary. It might be revised after reviewing. You are encouraged to leave your comment to each finding or at the end of this document. Please sign this document and have it stamped if you do not have any disagreement overall. To Vendor: This CAP should be completed and submitted to Kmart ES team within 10 working days after your receiving the soft copy from audit form. Please work with your factory to advise the corrective action plan and the completion date of each finding. The CAP should be completed in English. 1

1.1 Child Labour 1.2 Wages, Benefits and Working Hours 1.2a Wages and Benefits 结论 1: 社会保险参保不足 1.2a.6 违反了 中华人民共和国社会保险法 第十条, 职工应当参加基本养老保险, 由用人单位和职工共同缴纳基本养老保险费 第二十三条职工应当参加职工基本医疗保险, 由用人单位和职工按照国家规定共同缴纳基本医疗保险费 第三十三条职工应当参加工伤保险, 由用人单位缴纳工伤保险费, 职工不缴纳工伤保险费 第四十四条职工应当参加失业保险, 由用人单位和职工按照国家规定共同缴纳失 The facility should ensure all employees participate in social insurance according to the Law. 企业应按法规要求为员工 参加社会保险 To request all employees to participate in social insurance according to the Law. 尽量要求所有 工人按法规参与保险 31/12/2016 业保险费 第五十三条职工应当参加生育保险, 由用人单 位按照国家规定缴纳生育保险费, 职工不缴纳生育保险 费 2

证据 : 通过查阅企业提供的 2016 年 11 月的社保收据, 发 现在 2016 年 11 月,34 人中有 20(59%) 名员工参加了工伤 保险和医疗保险,34 人中有 18(53%) 名员工参加了生育保 险, 养老保险和失业保险 备注 : 工厂没有获得社保批文, 但是工厂在 2016 年 3 月 24 日为 40 名工人向中国平安财产保险股份有限公司购买 了商业团体意外险 Finding 1: insurance. Not all employees received all required social It violated Social Insurance Law of the People s Republic of China, Article 10 Employees shall participate in the basic endowment insurance, and the basic endowment insurance premiums shall be jointly paid by employers and employees. Article 23 Employees shall participate in the basic medical insurance for employees, and the basic medical insurance premiums shall be jointly paid by employers and employees in accordance with the relevant provisions of the state. Article 33 Employees shall participate in the employment injury 3

insurance, and the employment injury insurance premiums shall be paid by their employers rather than the employees. Article 44 Employees shall participate in unemployment insurance, and the unemployment insurance premiums shall be jointly paid by employers and employees in accordance with the relevant provisions of the state. Article 53 Employees shall participate in maternity insurance, and the maternity insurance premiums shall be paid by employers rather than employees in accordance with the relevant provisions of the state. Evidence observed: Through review the social insurance receipt of November 2016, it was noted that only 20 out of 34 (59%) employees had participated in employment injury insurance and medical insurance; and only 18 out of 34 (53%) employees had participated in maternity insurance, basic endowment insurance and unemployment insurance. Remark: The facility did not obtain social insurance wavier, but the facility had signed a commercial group accident insurance with Pingan Property & Casualty Insurance Company Of China 4

Ltd for 40 employees on March 24, 2016. 1.2b Working Hours 结论 1: 月加班超时 违反了 中华人民共和国劳动法 第 41 条, 用人单位由于生产经营需要, 经与工会和劳动者协商后可以延长工作时间, 一般每日不得超过一小时 ; 因特殊原因需要延长工作 The facility should reduce the overtime hours to ensure it is within 36 hours per month. 时间的, 在保障劳动者身体健康的条件下延长工作时间每月不得超过三十六小时 企业应减少员工的加班时 间确保每月的加班时间不 1.2b.6 超过 36 小时 To add more employees. 增加人手 30/06/2017 证据 : 通过文件审核, 审核员发现在抽取的 2016 年 9 月份 ( 当前月 ) 的考勤中,10 名随机抽取的员工中有 6 人的月 加班时间为 38-68 小时, 在抽取的 2016 年 5 月份 ( 随机 月 ) 的考勤中,10 名随机抽取的员工中有 4 人的月加班时 间为 65-71 小时, 在抽取的 2015 年 10 月份 ( 随机月 ) 的考 勤中,10 名随机抽取的员工中有 6 人的月加班时间为 39-62 小时. Finding 1: Excessive OT hours 5

It violated the PRC Labour Law article 41 The employing unit may extend working hours due to the requirements of its production or business after consultation with the trade union and labourers, but the extended working hour for a day shall generally not exceed one hour; if such extension is called for due to special reasons, the extended hours shall not exceed three hours a day under the condition that the health of labourers is guaranteed. However, the total extension in a month shall not exceed thirty-six hours. Evidence observed: Through document review, auditor found that the monthly overtime hours of 6 out of 10 employees were ranged from 38 to 68 hours in September 2016 (current month), the monthly overtime hours of 4 out of 10 employees were ranged from 65 to 71 hours in May 2016 (random month), and the monthly overtime hours of 6 out of 10 employees were ranged from 39 to 62 hours in October 2015 (random month). 1.3 Forced/Bonded Labour 6

1.4 Discrimination 1.5 Harassment and Abuse 1.6 Freedom of Association and Collective Bargaining 1.7 Health and Safety 1.7a General Environmental Health and Safety 1.7b Emergency/Fire Preparedness 1.7b.22 结论一 : 工厂宿舍没有安装烟雾探测器 另外, 车间和仓库安装的烟雾探测器未连接到消防警报系统 违反了 K-mart 要求 : 企业应为宿舍安装烟雾探测器, 且烟雾探测器需要连接到消防警报系统 证据 : 通过现场审核, 审核员发现企业宿舍没有安装烟雾探测器, 而车间和仓库安装的烟雾探测器未连接到消防警报系统 The facility should install the smoke detectors in the dormitory, and should ensure that the smoke detectors in dormitory, canteen, warehouse and workshop are connected with the fire alarm system. 企业应为宿舍安装烟雾探 测器, 且烟雾探测器需要 连接到消防警报系统 To install the smoke detectors in the dormitory, and make the smoke detectors in dormitory, warehouse and workshop connected with the fire alarm system. 为宿舍安装烟雾 探测器, 且连接宿舍, 仓库和车间 的烟雾探测器到消防警报系统 30/06/2017 Finding 1: There was no smoke detector in the dormitory, and 7

the smoke detectors installing in the warehouse and workshop were not connected with the fire alarm system. It violated Kmart Ethical Sourcing Code; smoke detectors should be installed in the facility and connecting with the fire alarm system. Evidence observed: Through facility tour, auditor noted that there was no smoke detector in the dormitory, and the smoke detectors installing in the warehouse and workshop were not connected with the fire alarm system. 1.7b.23 结论一 : 工厂未安装喷淋系统 违反了 K-mart 要求 : 企业需要安装喷淋系统 证据 : 通过现场审核, 审核员发现工厂没有安装喷淋系统 It is suggested to install the fire sprinkler as a best practice, especially when the local law is absent. Make sure your facility has taken corrective action to other findings and completed. It is acceptable that the facility proposes a long term action plan to implement the To install fire sprinkler system in facility in the future. 将来会安装喷 淋系统 30/06/2017 8

Finding 1: The fire sprinkler system was not installed in the facility. Evidence observed: Through facility tour, auditor noted that the fire sprinkler system was not installed in the facility. installation at current stage. For example, you can start with consulting a qualified organization or unit about the cost, feasibility, etc. of installing a fire sprinkler system. 安装消防喷淋系统作为最 佳实践推荐给工厂, 特别 是在当地法律没有作出明 确要求的前提下 请确保 在此之前已经针对其他问 题做出改善并已完成 目 前, 工厂将安装消防喷淋 系统作为一个长期的计划 是可以接受的 例如, 工 厂可以尝试从向有资质的 部门或机构咨询安装的成 本以及可行性入手 1.7c Accommodations 9

1.7d Building Integrity 2. Environment 3. Business Integrity and Anti-corruption 4. Compliance with the Law 5. Management Systems 6. Compliance with our Ethical Sourcing Code Factory comments 10