Enhancement of COP in Vapour Compression Refrigeration System

Similar documents
Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

II. OBJECTIVE OF RESEARCH

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

Design & Fabrication of Hybrid Cooler

Waghmare Tushar Ramrao, D.S.Nakate

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

Performance Optimization of the Evaporative Condenser Design

Performance of an Improved Household Refrigerator/Freezer

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

To Improve Cop of Domestic Refrigerator with the Help of Water Cooling Condenser

EXPERIMENTAL VERIFICATION OF PERFORMANCE OF CAPILLARY TUBE USING VAPOUR COMPRESSION REFRIGERATION SYSTEM

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Pressure Enthalpy Charts

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Improvement Of Energy Efficiency Ratio Of Refrigerant Compressor

Reheating Refrigeration System

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

Performance Evaluation of VCRS with Nested Helical Shaped Condenser by Using R134a as Refrigerant

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

Numerical Simulation of Window Air Conditioner

Capillary Tube and Thermostatic Expansion Valve Comparative Analysis in Water Chiller Air Conditioning

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

EXPERIMENTAL INVESTIGATION OF VAPOUR ABSORPTION SYSTEM

STUDY OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING DOUBLE PIPE HEAT EXCHANGER

Performance Assessment of Water Cooled Condenser Refrigeration System

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

EXPERIMENTAL INVESTIGATION ON RECOVERY OF WASTE HEAT FROM WINDOW AIR CONDITIONER

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN

[Jhansi, 5(10): October 2018] ISSN DOI /zenodo Impact Factor

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Modified Air Cooler with Split Cooling Unit

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Optimum Length of a Condenser for Domestic Vapor Compression refrigeration System

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants


Experimental Study of Modified Refrigerator Cum Air Conditioning and Water Cooler System

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners

Cost-Effective COP Enhancement of a Domestic Air Cooled Refrigerator using R-134a Refrigerant

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

Performance investigation of Air-conditioning system using ejector as expansion device

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

ISSN Vol.08,Issue.21, November-2016, Pages:

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Performance Enhancement of Mini Refrigerator with Phase Change Materials

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Compendium DES July 2016, CARN

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Design and Development of Water Cooled Condenser for Domestic Refrigerator

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Global Journal of Engineering Science and Research Management

FABRICATION OF REFRIGERANT FLOW RATE WITH SPIRALLY COILED CAPILLARY TUBE

A Comparison Between Refrigerants Used In Air Conditioning

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

ADVANCES in NATURAL and APPLIED SCIENCES

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

Dhulapally, Secunderabad Subject: REFRIGERATION AND AIR CONDITIONING QUESTION BANK

Experimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Transcription:

Enhancement of COP in Vapour Compression Refrigeration System M. Krishna Prasanna #1 M.E student, Heat Transfer studies in Energy Systems Department of Mechanical Engg., Andhra University Visakhapatnam-530003, A.P, India. P. S. Kishore *2 Ph.D, Professor, Department of Mechanical Engg., Andhra University Visakhapatnam-530003, A.P, India Abstract: Experimental analysis on vapour compression refrigeration (VCR) system with R-12 refrigerant was done and their results were recorded. The effects of the main parameters of performance analysis such as mass flow of refrigerant, degree of sub cooling and super heating on the refrigerating effect, coefficient of performance (COP) and power required to run the compressor for various evaporating temperatures, percentage increase in COP and percentage reduction of power required to run the compressor for VCR are dealt. Further the investigations are carried out by introducing shell and coil heat exchanger at the end of compressor. Keywords: Vapour compression refrigeration, Heat exchanger, COP, power. I. INTRODUCTION Vapour compression refrigeration system is based on vapour compression cycle. Vapour compression refrigeration system is used in domestic refrigeration, food processing and cold storage, industrial refrigeration system, transport refrigeration and electronic cooling etc. So improvement of performance of system is too important for higher refrigerating effect or reduced power consumption for same refrigerating effect. By sub-cooling using heat exchanger at condenser inlet refrigerating effect increases and power consumption or work input decreases. Thus performance of cycle is improved. Along with this waste heat also recovered. The essential quantity of heat recovered is not the amount but it is value. Lokapure and Joshi [1] In their article dealt energy conservation by using technique of utilizing waste heat from air-conditioning system and increasing COP. They said that the refrigeration heat recovery device is indirect type of system in which a refrigerant to water heat exchanger is installed between the host refrigeration system compressor and condenser. In this case they achieved their goal by recovering energy and improving COP up to 13%. Khurmi and Gupta [2] in their book gave evidence that the process of under cooling is also brought about by employing a heat exchanger. This increases refrigerating effect and finally improved coefficient of performance in vapour compression refrigeration system. Domanski [3] investigated the effect of LLSL-HX (Liquid line/ Suction line heat exchanger) on system performance by taking liquid refrigerant from condenser to exchange heat with vapor refrigerant from evaporator. They reported that coefficient of performance was increased after installing LLSL-HX. Jain et al. [4] analyzed a complex system in order to utilize waste heat rejected by condenser to the atmosphere by installing additional water cooled condenser. Baskaran and Mathews [5] described systems including various refrigerants improved by analyzing the effect of the super heating / sub cooling case. Better performance coefficient values (COP) than those of nonsuper heating /sub cooling case are obtained. Rajput [6] in his book concluded that sub-cooling results in increase of C.O.P and said that no further energy has to be spent to obtain the extra cold coolant. Thirumaleshwar [7] proposed correlations for overall heat transfer coefficient for parallel and counter flow heat exchangers. Coronel and Sandeep [8] determined convective heat transfer coefficient in both helical and straight tubular heat exchangers under turbulent flow conditions. The experiments were conducted in helical heat exchangers and their study shows that the heat transfer coefficient in coiled tubes is higher than that in straight tubes. II. SYSTEM DESCRIPTION AND DESIGN Heat flows naturally from hot to colder body. But, in refrigeration system there is opposite phenomena i.e. heat flows from a cold to a hotter body. This is achieved by using a substance called a refrigerant. The refrigerant (R- 12) absorbs heat and hence evaporates at a low pressure to form a gas. This gas is then compressed to a higher pressure, such that it transfers the heat it has gained to ambient air or water and turns back (condenses) into a liquid. Thus, heat is absorbed, or removed, from a low temperature source and transferred to a higher temperature source. The refrigeration cycle can be broken down into the following stages as in Fig 1. Fig.1: Schematic diagram of a proposed VCR System 1535

Considering Fig.2, 1-2, the saturated vapour enters the compressor where its pressure is raised. There will also be a big increase in temperature, because a proportion of the energy input into the compression process is transferred to the refrigerant. 2-3, the high pressure superheated vapour passes from the compressor into the condenser. There will be decrease in temperature due to condensation process. The cooling for this process is usually achieved by using air. After condensation, refrigerant enters the expansion device. 3-3, shell and coil heat exchanger is installed between the host refrigeration system compressor and condenser. Water is circulated through one side of heat exchanger and hot refrigerant gas from the compressor is routed through the other side. Heat is transferred from the hot refrigerant gas to the water thus refrigerating effect increases and power consumption or work input decreases. Thus performance of cycle is improved. Along with this waste heat also recovered. 3-4, the high-pressure liquid refrigerant passes through the expansion device, which both reduces its pressure and controls the flow into the evaporator. 4-1, Low pressure liquid refrigerant in the evaporator absorbs heat from its surroundings. During this process it changes its state from a liquid to a gas, and at the evaporator exit is slightly superheated. Fig.2: p-h diagram of a basic VCR and VCR with heat exchanger (A) Shell and Coil Heat Exchanger: Fig.3: HEAT EXCHANGER COIL (modeled in Pro-E) (B) Heat Exchanger Unit: 1) Overall heat transfer coefficient. 1/U = 1/hi + 1/ho + dx/k + F r + F w (1) 2) Outlet temperature of water t 2 = (Q/ ( m C p ))+ t 1 (2) 3) Log mean temperature difference. =ΔT m ΔT m = ΔT 1 -ΔT 2 / ln (ΔT 1 /ΔT 2 ) (3) 4) Area of Heat Exchanger A = Q/ U x ΔT m (4) 5) Length of the Tube, L = A / π x D o (5) III. ANALYSIS OF THE PROBLEM Based on T-s diagram of basic VCR as shown in Fig.4 1. Refrigerating effect =h 1 -h f3 (6) 2. Degree of superheat = T 2 - T 3 (7) 3. h 2 sup =h 2 + C pv (T 2 -T 2 ) (8) where h 2sup =enthalpy of vapour at superheated state C pv (specific heat at constant pressure for the superheated vapour) 4. Compressor work (W comp ) = h 2 sup -h 1 (9) Heat transfer in curved and helical circular tubes has been the subject of several studies due to the relatively high heat transfer coefficients associated with them. Flow in curved tubes is different from flow in straight tubes because of the presence of centrifugal forces. The centrifugal forces generate a secondary flow, normal to the primary direction of flow, with circulatory effects, that increases both the friction factor and the rate of heat transfer. The helically coiled heat exchangers generate a lot of turbulence thus a higher heat transfer coefficient obtained. If the unit is vertically installed, this reduces space requirements. Fig.3 shows heat exchanger coil which is modeled in Pro-E. Fig.4: T-s diagram of basic VCR 5. COP 1 = Refrigeration Effect Work done by compressor = h h (10) 1 f3 COP 1 = h2 sup h1 coefficient of performance of vapour compression refrigeration system without heat exchanger 1536

C O P Refrigerating effect (kj/kg) 6. Mass flow of refrigerant, The results are extended to refrigerating capacity of 2 TR m R = Refrigerating capacity (11) 60 x Wcomp x COP1 Where W comp = Compressor work 7. Heat available for desuperheating (Q) = m R (h 2 sup -h 2 ) (12) 8. Outlet temperature of water in heat exchanger (t 2 C) = (Q/ ( m C p ))+ t 1 (13) Where C p is specific heat of water t 1 = inlet temperature of the water t 2 = outlet temperature 9. Degree of under cooling(duc) = t 2 -t 1 (14) 10. h f3 = h f3 - C pl x DUC (15) Where h f3 =Enthalpy of liquid refrigerant (VCR with heat exchanger) C pl =Specific heat at constant pressure for the superheated liquid 11. COP 2 = Refrigeration Effect Work done by compressor = h1 hf3 (16) h h Where COP 2 = coefficient of performance of vapour compression refrigeration system with heat exchanger 12. % increase in COP = x100 (17) COP COP 13. m R1 = 14. (18) 2 sup 1 2 1 COP1 Refrigerating capacity 60 x W x COP m R1 =Mass flow of refrigerant when VCR with heat exchanger 15. P 1 = Refrigerating capacity (19) 60 x COP1 Where P 1 = Power required to run the compressor when VCR without heat exchanger 16. P 2 = Refrigerating capacity (20) 60 x COP2 Where P 2 = Power required to run the compressor when VCR with heat exchanger 17. % reduction of power required to run the compressor = x 100 (21) P P 1 2 P 1 comp 2 IV. RESULTS AND DISCUSSION 150.00 140.00 130.00 120.00 110.00 100.00-7 -4 0 2 5 Evaporation temperature ( C) RE without HE REwith HE for 1TR RE with HE for 2TR Fig.5: Evaporation temperature ( C) Vs Refrigerating effect (kj/kg) The results in above Fig.5 reveal that refrigerating effect increases when the heat exchanger is attached to VCR. This refrigerating effect further increases as the refrigerating capacity is increased from 1 TR to 2 TR. 7 6 5 4 3 2-7 -4 0 2 5-7 -4 0 2 5 Evaporation temperature ( C) R C is 1 TR R C is 2 TR COP without HE COP with HE Fig.6: Evaporation temperature ( C) Vs C O P The results in above Fig.6 reveal that the coefficient of performance increases when the VCR is connected to heat exchanger. This is further increases when the refrigerating capacity (RC) increased from 1 TR to 2TR. 1537

Outlet temperature of water ( C) 393.67 438.76 470.61 606.21 629.65 787.34 877.53 941.22 1212.41 1259.3 2.95 3.27 4.26 4.84 5.69 3.19 3.52 4.51 5.09 5.95 Power required to run the compressor (W) mass flow of refrigerant (m R ) (kg/s) 5.64 6.287 6.744 8.68 9.023 11.28 12.57 13.48 17.37 18.045 % increase in C O P 0.07 0.06 0.05 0.04 0.03 without HE for 1TR with HE for 1TR without HE for 2TR 18 16 14 12 10 8 6 4 2 0 0.02-7 -4 0 2 5 Evaporation temperature ( C) with HE for 2TR Degree of under cooling ( C) For 1 TR For 2 TR Fig.7: Evaporation temperature ( C) Vs Mass flow of refrigerant (kg/s) Fig.9: Degree of under cooling ( C) Vs percentage increase in C O P The results in above Fig.7 reveal that Mass flow of refrigerant is decreases when the VCR is connected to heat exchanger. This graph is plotted by taking VCR without heat exchanger, with heat exchanger for refrigerating capacities of 1 TR and 2 TR. 45 40 35 30 25 Heat available for desuperheating (W) RC 1TR RC 2 TR The results in above Fig.9 reveal that as the degree of under cooling increases the % increase in coefficient of performance also increases up to 16%. This is plotted by taking refrigerating capacities of 1 TR and 2TR. 1400 1200 1000 800 600 400 200 0 COP without HE C O P COP with HE Fig.10: C O P Vs Power required to run the compressor (W) Fig.8: Heat available for desuperheating (W) Vs Outlet temperature of water ( C) The results in above Fig.8 reveal that as the heat available for desuperheating increases, the outlet temperature of water in heat exchanger also increases. The power required to run the compressor is reduced up to 7.5% when the VCR (having refrigerating capacity of 1 TR) is attached to heat exchanger. The power required to run the compressor for a VCR without heat exchanger and VCR with heat exchanger both were plotted and shown in Fig.10 1538

2.95 3.27 4.26 4.84 5.69 3.44 3.77 4.75 5.347 6.213 Power required to run the compressor (W) 2500 2000 1500 ACKNOWLEDGMENT We, authors express gratitude to all the anonymous reviewers for their affirmative annotations among our paper. Thanks to every reviewer for reviewing our paper and give valuable suggestions. 1000 500 0 C O P COP without HE Fig.11: C O P Vs Power required to run the compressor (W) The power required to run the compressor is reduced up to 14% when the VCR (having refrigerating capacity of 2 TR) is attached to heat exchanger. The power required to run the compressor for a VCR with and without heat exchanger were plotted and shown in Fig.11 V. CONCLUSIONS COP with HE The following conclusions are arrived from the VCR system connected with heat exchanger when the evaporation temperature decreases to -7 C: 1. The refrigeration effect of the system is increased up to 16% using the heat exchanger with vapour compression refrigeration system. 2. The C O P (coefficient of performance) of the system is increased up to 16% using the heat exchanger with vapour compression refrigeration system. 3. Mass flow of refrigerant (m R ) is reduced up to 14% using the heat exchanger with vapour compression refrigeration system. 4. Heat available for desuperheating (Q) increases as the evaporation temperature decreases. So by attaching heat exchanger to the vapour compression refrigeration system and regulating water into heat exchanger, outlet temperature of the water (t 2 ) in heat exchanger increases. That hot water can be used for useful purpose. 5. Power required to run the compressor is reduced up to 14% by using the heat exchanger with vapour compression refrigeration system. REFERENCES [1] R.B. Lokapure and J.D.Joshi., Waste Heat Recovery through Air Conditioning System, International Journal of Engineering Research and Development, Vol 5, Issue 3, pp: 87-92, Dec 2012. [2] R.S.Khurmi and J.K. Gupta., Refrigeration and Air Conditioning, Eurasia publishing house Pvt Ltd, New Delhi, 2006. [3] P.A Domanski, Evaluation of Suction-Line/Liquid-Line Heat Exchanger in the Refrigeration Cycle, pp. 10-11, USA, 1995. [4] Rakesh Jain, Devendra Dandotiya and Abhishek Jain,Performance improvement of a Boiler through Waste Heat Recovery from an Air Conditioning Unit, International Journal of Innovative Research in Science, Engineering and Technology, Vol. 2, Issue 2, pp: 405-412, Feb 2013. [5] A.Baskaran and P.Koshy Mathews., A Performance Comparison of Vapour Compression Refrigeration System using Eco Friendly Refrigerants of Low Global Warming Potential, International Journal of Scientific and Research Publications, Vol. 2, Issue 9, pp: 4-7, Sept 2012. [6] R.K.Rajput, Thermal Engineering, Laxmi publications Pvt Ltd., 2006. [7] M. Thirumaleshwar, Fundamentals of Heat and Mass Transfer, Pearson Publications, New Delhi, 2006. [8] Pablo Coronel, K.P. Sandeep.,Heat Transfer Coefficient in Helical Heat Exchangers under Turbulent Flow Conditions, International Journal of Food Engineering, Vol 4, Issue 1,pp. 1-5, 2008 [9] Yunus A.Cengel, Heat and Mass Transfer, Third Edition, Tata McGraw-Hill Publication, 2000. [10] Frank P.Incropera and David P. Dewitt., Fundamentals of Heat and Mass Transfer, Wiley India Pvt Ltd, 2010 1539