Multi-Core Fire Resistant Cable

Similar documents
IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Caledonian Flame Retardant Coaxial Cables

CATEGORY 6A FTP RJ45 SOLUTION

Catalogue Telecommunication Cables INTRODUCCIÓN

Compact Module. Category 6A FTP Cabling System 1.1

FIRE RESISTANT CABLES FP200 GOLD

Telecommunication Cables

Caledonian Fire resistant Coaxial Cables

PRODUCT CATALOGUE Norröna

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

Flame Retardant Overall Screened Instrumentation Cables (multicore)

High Performance LSZH Fire Resistant Cable

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

FIRE RESISTANT CABLES FP200 GOLD

Product Specification CAT 6 UNSHIELDED PATCH CORDS

FIRE RESISTANT CABLES

BS /1000V XLPE Insulation LSZH Sheath Cables

S Low loss coax cables with foamed PE

FIRE PERFORMANCE CABLE

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

CABLES FOR ALARM AND SAFETY SYSTEMS

SHIELD TYPE MULTICONDUCTOR MULTIPAIR

ENHANCED FIRE PERFORMANCE CABLE

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Home Theater Cables. Your complete solution for high-end audio transmission, stereo, professional audio systems and home theater systems.

Comtran Cable. Hub-LINK Cables for Transit Applications

Arteor TM LCS2 Cat. 6A STP RJ 45 socket

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

The Next Generation of Data Communicatons Solutions

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

LSOH Flexible Cables

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

FIRE RESISTANT CABLES FP300

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

AMP NETCONNECT Category 5E SL Shielded Cabling System. 1. General Description

TYPE APPROVAL CERTIFICATE

Introduction.

SPECIAL ELECTRICAL AND OPTICAL CABLES

INTERNATIONAL STANDARD

PAIRED UNJACKETED. Insulation Nominal Anixter. Paired Conductors Thickness O.D. Number AWG Strand No. IN IN

STANDARDS INSTALLATION. Certificate No 077m

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE

INTERNATIONAL STANDARD

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Catalogue Power Cables

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

Caledonian fire Resistant signal & Data cables

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Total Fire Solutions. Includes BS 8519 and the updated BS :

Fire Resistant Cables

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Arteor TM LCS2 Cat. 6A UTP RJ 45 socket

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

Company Profile. We are dedicated to providing our customers competitive price and excellent service.

fire resistant cables

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

Category 5 Premise Wire

SAS Security and Alarm Safety Cables

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

FIRE RESISTANT CABLES FP400

Cat 6 Unshielded Patch cords

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Flexible Power Cable DLO

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Cable technology for highest safety requirements

/Oct/2014 Rev B

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Photovoltaic Cables EN H1Z2Z2-K

Security & Control Cables

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Special Provision No. 683S28 December 2017

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

/Oct/2014 Rev E

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

Catalogue. Instrumentation & Control Cables

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

PANDUIT 4-PAIR & MULTIPAIR COPPER DATA CABLE PLENUM RATED

Transcription:

Fire Resistant Cables / Multi-Core Fire Resistant Cable Approved to UL 444, Zeta ZFP series cables have received UL approval for standard applications. Standards Alarm Cable Z UL 444 Approval CMH Rated CM Rated CMR Rated CMX Rated CMG Rated UL Approval E3261 Data Capability ZFP series cables have excellent data/signal transmission characteristics, making it ideal for voice alarm, addressable and networked systems. Key application of ZFP series cables Conventional Fire alarm systems (detection & noti cation circuits) Addressable re alarm systems Voice alarm systems Emergency lighting Other essential service circuits Colour identi cation 2 Core: brown & blue 3 Core: brown, black & grey 4 Core: brown, blue, black & grey Outer Sheath: red or white Features Flame-retardant, low smoke & halogen free Anti re construction to prevent ame propagation Easy to install Superb working exibility 1mm, 1.5mm, 2.5mm & 4mm cable sizes available ble ZFP-215ER

Solid Copper Conductor Cores Aluminium Foil Shield Low Smoke Halogen Free Sheath Low Smoke Halogen Free Insulation Tinned or Bare Solid Copper Earth Wire Approval E326174 0001M TWO CORE ZFP Series THREE CORE ZFP Series FOUR CORE ZFP Series Model No. ZFP-210ER/H-100 ZFP-215ER/H-100 ZFP-225ER/H-100 ZFP-240ER/H-100 ZFP-310ER/H-100 ZFP-315ER/H-100 ZFP-325ER/H-100 ZFP-340ER/H-100 ZFP-410ER/H-100 ZFP-415ER/H-100 ZFP-425ER/H-100 ZFP-440ER/H-100 Nominal cross sectional area (mm 2 ) Conductor construction (Number of strands / Strand diameter) Mean overall diameter (mm) Approx. cable weight (kg/km) conductor resistance at 20 C (ohms/km) Enclosed current rating -DC or single phase AC (Amps) Clipped current rating -DC or single phase AC (Amps) Voltage drop -DC or single phase AC (mv/a/m) Part Number Key 1.0 1.5 2.5 4.0 1.0 1.5 2.5 4.0 1.0 1.5 2.5 4.0 1/1.13 1/1.38 1/1.78 7/0.85 1/1.13 1/1.38 1/1.78 7/0.85 1/1.13 1/1.38 1/1.78 7/0.85 7.2 7.8 9.5 11.6 7.4 8.4 10.4 12.3 8.5 10 11.9 13.5 78 93 140 195 88 116 180 248 107 143 225 310 18.1 12.1 7.4 4.6 18.1 12.1 7.4 4.6 18.1 12.1 7.4 4.6 13 16.5 23 30 13 16.5 23 30 13 16.5 23 30 15 19.5 27 36 15 19.5 27 36 15 19.5 27 36 44 29 18 11 44 29 18 11 44 29 18 11 /H-500 Ref Meaning Other Options ZFP Zeta re proof cable N/A 2 Number of conductors 3 or 4 10 Cable cross section area 1.5, 2.5 or 4.0 E Includes earth conductor N (No earth) R Outer sheath colour W (White) H Harmonized core insulation colours N/A 100 Reel length 100 metres 500m

Fire Resistant Cables / Data Communication Fire Resistant Cable (ZFP-UTP/H-305) Zeta Category 5E ( CAT 5 ) 4 pair cables consist of 24 AWG (0.51mm) bare copper conductors insulated with high density polyethylene. The insulated conductors are tightly twisted into pairs and covered with PVC material. The cable provides excellent high-speed transmission, and is certi ed to 155MHz and supports applications such as 155Mb/s ATM and 622Mb/s ATM using parallel transmission technology. It comes supplied on a 305 metre reel. Key Structure Conductor Inner insulation Outer jacket Nominal diameter Voltage rating Operation temperature range Impedance Velocity of propagation Propagation delay skew 24 AWG x 4 pairs solid copper wire PE Diameter 0.95mm LSZH matterial, thickness 0.8mm 5.50mm 300V -20 C to +75 C 100 +/- 15 Ohms/km 69% Nominal 45ns/100m NEXT PSNEXT ELFEXT PSELFEXT Near End Crosstalk is interference between two pairs of a cable measured at the same end of the cable as the transmitter Power Sum Near End Cross Talk is the algebraic sum of near end crosstalk (NEXT) of three wire pairs as they affect the fourth pair in a four-pair cable The Equal-Level Far-End Crosstalk (ELFEXT) test measures Far-End Crosstalk (FEXT). FEXT is very similar to NEXT, but happens at the receiver side of the connection Power Sum ELFEXT is the sum of FEXT values from 3 wire pairs as they affect the other wire pair Performance Frequency (MHz) Attenuation (db/100m) NEXT (db) PSNEXT (db) ELFEXT (db) PSELFEXT (db) Return Loss(dB) 0.722 1.8 1.6 67.0 82.6 64.0 79.2 66.0 82.3 63.0 80.4 1.0 2.0 1.9 65.3 83.2 69.3 80.4 63.8 79.6 60.8 77.4 20.0 24.7 4.0 4.1 3.8 56.3 63.3 53.3 67.7 51.7 64.0 48.7 60.4 23.0 29.6 8.0 5.8 5.3 51.8 67.8 48.8 64.0 45.7 57.1 42.7 56.2 24.5 31.9 10.0 6.5 6.0 50.3 63.6 47.3 59.7 43.8 54.8 40.8 52.7 25.0 33.0 16.0 8.2 7.7 47.3 58.7 44.3 55.5 39.7 54.5 36.7 51.2 25.0 33.2 20.0 9.3 8.6 45.8 58.5 42.8 55.3 37.7 49.7 34.7 47.3 25.0 31.6 25.0 10.4 9.7 44.3 54.2 41.3 52.9 35.8 45.2 32.8 44.8 24.3 32.8 31.25 11.8 10.9 42.9 57.0 39.9 54.5 33.9 44.5 30.9 42.0 23.6 33.2 62.5 17.1 15.7 38.4 52.5 35.4 50.1 27.8 37.2 24.8 34.9 21.5 31.0 100 22.0 20.1 35.3 49.2 32.3 46.2 23.8 32.3 20.8 30.1 20.1 29.3