Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 3 Heiselberg, Per Kvols. Publication date: 2016

Similar documents
Domestic Hot Water Profiles for Energy Calculation in Finnish Residential Buildings

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Aalborg Universitet. Diffuse Ceiling Inlet Systems and the Room Air Distribution Nielsen, Peter Vilhelm; Jensen, Rasmus Lund; Rong, Li

Field Study of Diffuse Ceiling Ventilation Performance in a Landscape Office

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 9 Heiselberg, Per Kvols. Publication date: 2016

The Performance of Diffuse Ceiling Inlet and other Room Air Distribution Systems Nielsen, Peter Vilhelm; Jakubowska, Ewa

DOMESTIC HOT WATER CONSUMPTION AND ITS IMPACT ON SYSTEMS WITH CIRCULATION

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 3 Heiselberg, Per Kvols. Publication date: 2016

for family composition, time allocation of people, ownership and specification of home appliances. This paper first presents the simulation procedure

Heat Consumption Assessment of the Domestic Hot Water Systems in the Apartment Buildings

On the Architectural Engineering Competences in Architectural Design MSc in Engineering with Specialization in Architecture Kirkegaard, Poul Henning

Air and operative temperature measurements in a plus-energy house under different heating strategies

Households' energy use - which is the more important: efficient technologies or user practices? Gram-Hanssen, Kirsten

SOLAR HOT WATER AND HEAT PUMP BOOSTER ENERGY CALCULATION METHODOLOGY

Copyright 2003 IBACOS, Inc. All rights reserved.

Laboratory study on the cooling effect of flash water evaporative cooling technology for ventilation and air-conditioning of buildings

ENERGY CONSUMPTION OF HOUSES AND LIFESTYLE IN COLD CLIMATIC AREA OF JAPAN

Daikin Altherma Selection Report

Statistical Predictions of Electric Load Profiles in the UK Domestic Buildings

Impact of Air Distribution on Heat Transfer during Night-Time Ventilation

Air Distribution and Ventilation Effectiveness in a room with Floor/Ceiling Heating and Mixing/Displacement Ventilation

Acknowledgement: Ralph Prahl, Prahl & Associates, contributed critical review and analysis

series publication University Aalto DISSERTATIONS OCTORAL D / 2018 for schedules building usage xtensive E simulation completed with nergy e hot

SURVEY ON THE OCCUPANT BEHAVIOR RELATING TO WINDOW AND AIR CONDITIONER OPERATION IN THE RESIDENTIAL BUILDINGS

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Maximum Obtainable Efficiency For Engines And Refrigerators Based On The Stirling Cycle

Can painted glass felt or glass fibre cloth be used as vapour barrier?

Performance of Solar Water Heating Systems in the United States

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

Survey on Cooling Costs and Related Factors for Apartments in an Urban. Area of Osaka

Indoor Thermal Environment of Residential Buildings in Three Cities of China

Asparagus Response to Water and Nitrogen

Sivu 2/8 Rate data Description Suomi Shut off times total 0.0 h/day Weekends with shut off times yes Daytime rate of heat pump Time for daytime rate 5

Comparison of radiant and convective cooling of office room: effect of workstation layout

An interdisciplinary approach to identify adaptation strategies that enhance flood resilience and urban liveability

Assessment of Domestic Evacuated Tube. Direct Solar Water Heater

To describe human body heat transfer, the concept. Thermal comfort with radiant and convective cooling systems. Articles. REHVA Journal June

Data-Driven Energy Efficiency in Buildings

Evaluation on Residential Energy Efficiency Programs Using the City-Scale End-Use Simulation Model

Identification of Aberrant Railroad Wayside WILD and THD Detectors: Using Industry-wide Railroad Data. June 10, 2014

Economic Analysis of Solar Assisted Chemical Heat Pump Dryer

BNWAT28: Water consumption in new and existing homes

A NOVEL METHODOLOGY FOR GENERATING RESIDENTIAL BUILDINGS ELECTRICITY DEMAND PROFILES

Indoor Moisture Control of Auckland Houses with Different Ventilation Systems

THE EFFECT OF HEAT LOAD ARRANGEMENT ON THE PERFORMANCE OF RADIANT PANELS

The Remodeling Market

Performance of Chilled Beam with Radial Swirl Jet and Diffuse Ceiling Air Supply in Heating Mode

ANALYSIS OF RESIDENTIAL ROOM TEMPERATURE AND OCCUPANT S THERMAL COMPLAINT IN WINTER FIELD SURVEY

Appendix A. Reference Evapotranspiration (ETo) Table.

Electrical Fires in Finland

Thermal Comfort with Convective and Radiant Cooling Systems

Keep your electricity bill cool this summer

Shifting Patterns of Water Demand: Socio-Demographic Challenges for Water Managers

Residential Structure Match or Lighter Ignited Fires

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review

Remodeling Market. Kermit Baker. Remodeling Futures Conference November 9, Harvard University JOINT CENTER FOR HOUSING STUDIES

Kimberly Rollins, Professor, Department of Economics, University of Nevada, Reno

Case Virkakatu, Oulu, Finland

MSP WRAP-AROUND MULTIPLE SMALL PLATE DEHUMIDIFICATION TECHNOLOGY VS. CONVENTIONAL DEHUMIDIFICATION IN DEDICATED OUTDOOR AIR SYSTEMS (DOAS)

Villa Bagatelle Technical Report

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

Performance of Heat Recovery Ventilation System with Ground Source Brine Heat Exchanger Pre- Heating System in the Context of nzeb

Functionality Inspection of Interconnected Fire Protection Systems

AERECO DEMAND CONTROLLED VENTILATION COMBINING INDOOR AIR QUALITY AND ENERGY SAVINGS

Abstract. Cuvinte cheie: caisa, radacina, profil de sol Keywords: apricot, root, cavity. 1. Introduction

MILK DEVELOPMENT COUNCIL

COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS

Human response to thermal environment in rooms with chilled beams

VARIABLE HEAT RECOVERY IN DOUBLE BUNDLE ELECTRIC CHILLERS. Richard J Liesen 1, Rahul J Chillar 2 1 University of Illinois at Urbana Champaign

EMPIRICAL MODEL SIMULATING RAINWATER HARVESTING SYSTEM IN TROPICAL AREA

Better Buildings By Design 2013 Building the Renewable Energy Ready Home Solar Thermal Lessons Learned and Results

URBAN WATER DEMAND IN SPANISH CITIES BY MEASURING END USES CONSUMPTION PATTERNS

Saying Mahalo to Solar Savings: A Billing Analysis of Solar Water Heaters in Hawaii

Characterizing large residential appliance peak load reduction potential utilizing a probabilistic approach

Strategies for Summer Utility Savings. Residential Environmental Program Series May 15, 2013

COOLED PLATE TESTS ON TEXTILE MATERIALS IN SIMULATED COCKPIT UNDER SOLAR RADIATION

Generation gap: How baby boomers and millennials stack up in their perceived and actual electricity use. Report. March 2019 BCH19-217

INEEL (1500) [45] 5.6 C 217 mm 60. Precipitation (mm) Temperature (oc) Month

AMOUNT OF MOISTURE PRODUCTION AND FIELD MEASUREMENT IN DRESSING ROOM

Computer Modelling and Simulation of a Smart Water Heater

Research on Decision Tree Application in Data of Fire Alarm Receipt and Disposal

DAYLIGHTING PERFORMANCE ON VENETIAN BLIND FOR HEALTHY APARTMENT HOUSING

Hygrothermal evaluation of a museum storage building based on actual measurements and simulations

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

THE RISK OF LEGIONELLA DEVELOPMENT IN SANITARY INSTALLATIONS

Thermal Environment Evaluation in Commercial Kitchens of United States

Energy Efficiency Potential of Heat Pump Water Heaters in Commercial Buildings

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Household Rainwater Tanks and Peak Demand Factors

AN ANALYSIS OF THE ACTUAL THERMAL PLUMES OF KITCHEN APPLIANCES DURING COOKING MODE

HYGROTHERMAL PERFORMANCE BENEFITS OF THE CELLULOSE FIBRE THERMAL INSULATION STRUCTURES

The importance of hot water system design in the Passivhaus

GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE

Hot Water a Hot Commodity Better Buildings by Design, February 2012 Burlington, VT

The influence of vegetation and climate on clay earthwork slopes. Dr Joel Smethurst Faculty of Engineering and the Environment

Energy & Water Savings in Commercial Food Service

Full Season Comparison of Weather Based Smart Controllers

High Efficiency Heat Pump for Domestic Hot Water Generation

You will investigate the electrical consumption in your home over the course of TWO days (48 hour period).

Transcription:

Downloaded from vbn.aau.dk on: april 09, 2019 Aalborg Universitet CLIMA 2016 - proceedings of the 12th REHVA World Congress volume 3 Heiselberg, Per Kvols Publication date: 2016 Document Version Publisher's PDF, also known as Version of record Link to publication from Aalborg University Citation for published version (APA): Heiselberg, P. K. (Ed.) (2016). CLIMA 2016 - proceedings of the 12th REHVA World Congress: volume 3. Aalborg: Aalborg University, Department of Civil Engineering. General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights.? Users may download and print one copy of any publication from the public portal for the purpose of private study or research.? You may not further distribute the material or use it for any profit-making activity or commercial gain? You may freely distribute the URL identifying the publication in the public portal? Take down policy If you believe that this document breaches copyright please contact us at vbn@aub.aau.dk providing details, and we will remove access to the work immediately and investigate your claim.

ly Consumption Profiles of Domestic Hot Water for Finnish Apartment Buildings Kaiser Ahmed 1, *, Petri Pylsy 1, 3, Jarek Kurnitski 1, 2 1 Aalto University, Department of Civil and Structural Engineering, Finland 2 Tallinn University of Technology, Faculty of Civil Engineering, Estonia 3 The Finnish Real Estate Federation, Finland *Corresponding author: Rakentajanaukio 4 A, FI-02150 Espoo, Finland; E-email: kaiser.ahmed@aalto.fi Abstract The hourly profile of domestic hot water (DHW) is required for system sizing and energy simulations. This paper addresses the hourly DHW profiles for Finnish apartment buildings. The hourly consumption of 191 occupant during one year data were processed. ly profile for August, November and January had similar consumption pattern and monthly variation of consumption were also illustrated. Higher variation of consumption was noticed during peak hours and 90% of consumption variation were in between the range of 0-20 L/per./hour. The average consumption during peak and non-peak hours were 3.6 and 1.5 L/per./hour respectively. To understand the effect of the number of occupants on hourly peaks five profiles were drawn for one person, 3 people, 10 people, 31 people and 191 people group. All profiles followed similar DHW consumption pattern and a specific selection procedure was applied for a number of good candidates in order to select the most representative real consumption data based profile for each group. The results revealed higher evening peaks compare to morning peak and smaller groups had a higher peak consumption values compared to large groups. The obtained profiles accompanied by scaling factor can be used with monthly consumption factor of DHW to deliver the hourly profile for any month. Average DHW ratio was 0.31 and varied from 0.10 to 0.39, but was not sensitive to hourly consumption. Keywords - Domestic hot water, hourly profile, DHW ratio 1.0 Introduction Domestic hot water (DHW) accounts the second largest use of energy, next to space heating, in Finnish buildings [1]. Almost 72% of DHW volume are consumed by the residential building and rest of them are used in small and large scale office buildings [2]. Washing, bathing, laundry, drinking and cleaning are the main purposes of DHW usages. Experience has shown that DHW consumption depends on many factors such as user behavior, occupancy rate, demographic location, climate condition, user age, income, appliance quality etc. The average daily consumption of DHW for Finnish

and Swedish are 46 and 33 L/per./day respectively [3, 4]. Considering the consumption variation during a year authors developed monthly consumption factor for Finnish residential building in [5] which summary is shown in table 1. Furthermore, hourly DHW consumption pattern seems to be unique characteristic for every country. Germans consume higher DHW at morning and lower during evening whereas Finnish people consumption pattern are opposite [6]. Vine et al. investigated DHW hourly consumption of four low income apartment buildings in California. The obtained profile was drawn based on hourly average of 15 units DHW consumption for a short duration [7]. In another study [8], hourly water consumption profile was drawn by summing up the consumption of all end uses. This result was obtained based on statistical data of user in household and each end uses information i.e., frequency of occurrence, flow intensity and duration. In this study, authors have applied different approach. Authors are considered each apartment hourly basis consumption from smart metering system and exact occupant number. The information of each end uses were not available. ly profiles were drawn based on selection of actual representative consumption profiles of induvial occupants. The results show real peaks which were strongly damped when larger groups of occupants were analyzed. Method 2.1. Description of target building and apartments The study is accomplished based on the actual hourly consumption of domestic hot water (DHW) and cold water (DCW) data from 86 Finnish apartments. All apartments with 191 occupants belong to one large rental apartment building which is located in Helsinki, Finland. Table 2 lists the apartment number, apartment type and family size. Table 2: Apartment number, apartment type and family size in building Apartment type No Occupancy in apartment No One room apartment 2 One person occupied 24 Two room apartment 20 Two people occupied 31 Three room apartment 27 Three people occupied 15 Four room apartment 30 Four people occupied 15 Five room apartment 7 Five people occupied 1 Most of the Finnish population are living in Helsinki, Tampere and Turku which are covered by climate zone 1 and 2. The annual average outdoor

temperature of climate zone 1 and 2 are 5.3 and 4.6 C respectively. The study data represents well the majority of Finnish population, however some Northern part of Finland having extreme winter may apply different profiles of DHW. The obtained profile with monthly correction factor from [5] could consider as hourly user profile of DHW for Finnish apartment building. The required heating energy for space heating and DHW was supplied by the central district heating system of all rented apartments. The required energy for DHW was measured in kwh. The data was collected from 01.05.2014 to 34.2015 with 1 hour interval period. According to Finnish building code the minimum and maximum value of supply water temperatures are 55 and 65 C respectively which are usually in the range between 55 to 60 C. In this study, the maintenance staff confirmed that the supply water temperature compliance with the minimum Finnish building code value of 55 C [9]. Each apartment had two individual meter which was taken readings of DHW and DCW separately. Occupants were using DHW for bathing, shower, body washing and kitchen facilities. Each apartment also own dishwasher and washing machine but those were not connected with DHW but DCW. 2.2. Data measurements The accuracy level of measurement devices was good i.e., ± 2 %. The measured data were stored in a database with a resolution of 1.0 liter. The individual smart water metering system provided measurement for each apartment as follows Cumulative meter readings of hourly consumption of DHW for each apartment in liter. Cumulative meter readings of hourly consumption of DCW for each apartment in liter. Authors consider month of November and August as representative month of summer and winter DHW consumption. Furthermore, some data cleaning are also accomplished during data processing work. Data is not taken into account if the apartment was vacant for whole month or daily average consumption of individual was less than 20 liter/per./day. 2.3. Data analysis ly basis data of 86 apartments were separated according to month of November, August and January. Cumulative meter readings of hourly consumption of DHW and DCW for each apartment in liter for month of November were processed. The data presents the apartment hourly consumption which is further divided by the number of occupant from respective apartment. Occupants were numbered properly for proper

identification. The daily consumption sum of each day from 1.11.2014 to 30.11.2014 for individual occupant was calculated. Daily basis consumption (L/per/day) of November (30 individual days) were calculated. Afterwards an average of 30 days was calculated to get the daily average of November. The number of occupants are 191 which eliminates to 164 and ensured minimum daily consumption of 20 L/per./day. 164 occupants hourly consumption data from 1.11.2014 to 30.11.2014 are separated based on individual hour i.e., 1.0 hour to 24 hours. The average of each hour of 164 occupants were obtained which presents the hourly profile of daily consumption for month of November. The authors have formed 5 different random groups of 1 person group, 3 people group, 10 people group, 31 people group, and 191 people group. For one person hourly consumption profile authors considered 164 occupants individual profile. 15 profiles closest to the average daily consumption were selected for further analyses. Among these 15 profiles 4 good candidates were selected based on similarity with the shape of the average consumption profile representing the hourly consumption profile for 1 person group. For 3 people group, authors used Excel RAND function to randomly pick three occupants among 164 occupants and to form 3 people groups. The total number of combination was 164 and each group had own profile that was accomplished from the hourly average of 3 occupants. Among 164 profiles 15 profiles were selected which have nearly similar daily consumption to average of all occupants daily consumption. Again 4 different candidates were chosen which represent hourly consumption profile for 3 people group. The same procedure was followed to draw the user profile of DHW for 10 people group and 31people group. The random selection procedure was repeated 3 times in order to be sure that the selection of groups will not affect the results. 1:00 5:00 7:00 9:00 11:00 1 17:00 19:00 21:00 2 P1 P2 P3 P4 (a) 1:00 5:00 7:00 9:00 11:00 1 17:00 19:00 21:00 2 P1 P2 P3 P4 (b)

1:00 5:00 7:00 9:00 11:00 1 17:00 19:00 21:00 2 P1 P2 P3 P4 P1 P2 P3 P4 (c) (d) Figure 1: Similar candidates of November for group a) 31 people, b) 10 people, c) 3 people, and d) 1 person. The daily consumption of DHW for each month was obtained by multiplying the monthly consumption factor with annual daily average. Afterward, scaling factor has assigned for each group which further multiply with hourly consumption of respective group. The following equation was used to form scaling factor,, = Furthermore, domestic cold water hourly profile of 164 occupants for month of November has drawn. The hourly ratio of DHW to DCW (total) is calculated by using the following equation = Where, DTW is consumption of total water (Hot + Cold). 3.0 Result and discussion The result was drawn based on the hourly DHW and DCW consumption of 191 occupants from 86 Finnish apartments in Helsinki region. The hourly consumption data during one year was find representative because of similar average consumption values compared to larger and longer data set of [5]. However, the quality of proposed profile might be increased if authors could manage couple of consecutive year data. It was found higher variation of DHW consumption during a day than in previous study [5]. Similar findings are also observed in this study where daily consumption is varied from 0 300 L/per./day during data processing of individual data set of 191 occupants. 1 15.0 1 9.0 3.0 1:00 5:00 7:00 9:00 11:00 1 17:00 19:00 21:00 2

Table 1 DHW monthly consumption factor for Finnish apartment building Annual average consumption, L/per./day Jan. Feb. Mar. Apr. May Jun. Jul. Aug. 43 1.105 1.04 1.033 1.005 0.977 0.895 0.88 0.964 Table 2: ly consumption factor of different groups for month of November. 1:00 2:00 4:00 5:00 6:00 7:00 8:00 9:00 10:00 11:00 12:00 1 14:00 16:00 17:00 18:00 191 Per. 0.47 0.17 7 7 3 0.10 0.50 1.95 1.65 1.09 1.20 1.12 1.13 0.88 0.71 0.76 0.82 0.85 31 Per. 0.45 0.14 6 6 4 0.12 0.55 1.82 1.77 0.81 0.94 0.92 1.10 0.89 0.78 0.97 0.95 0.94 10 Per. 0.21 6 3 3 1 4 0.34 2.37 2.22 1.31 1.33 0.63 0.79 0.62 0.53 0.56 0.73 0.84 3 Per. 0.83 0.28 1 1 1 3 0.44 3.10 0.96 0.65 1.03 1.20 1.51 0.93 0.41 0.25 0.47 0.66 1 Per. 2 0 0 0 0 1.58 0.38 5.57 0.92 0.83 1.50 1.46 0.57 0.47 0.77 0.98 0.53 0.64 Sep. Oct. 0.969 0.98 19:00 20:00 21:00 1.06 1.97 2.51 0.94 1.87 2.30 1.29 3.46 3.02 1.13 1.92 3.60 1.35 3.06 1.53 Nov. 1.111 22:00 2 9 1.82 2.54 1.85 1.23 1.78 2.20 1.89 0.96 0.55 Dec. 1.041 0:00 0.98 1.20 0.59 0.47 0.32

The data was analyzed to quantify the hourly variation of DHW. In morning peak (7.00 to 9.00) and evening peak (20 to 20) the consumption rates varied from 0 to 78 L/per./hour. Some common behavior were also noticed such as low consumption rate during 11.00 to 10 hours, almost no consumption from 1:00 to 5:00 hours and high consumption rate during morning and evening peak hours. The average during peak and nonpeak hours were 3.6 and 1.5 L/per./hour respectively. In figure 2 is shown the frequency distribution at peak and non-peak hours. 60% 8:00 50% 20:00 50% 40% Frequency 40% 30% 20% 10% 0% Frequency 30% 20% 10% 0% 1 1 1 1 1 2 Consumption rate, L/per./hr 1 1 1 1 1 2 Consumption rate, L/per./hr 100% 80% Frequency 80% 60% 40% 20% 0% 1 1 1 1 1 2 Consumption rate, L/person/hr Figure 2: Frequency distribution at peak hours of 8 hour, 20 hour and non-peak hours of 3 hour, 15 hour for month of November. Almost 90% of consumption were kept in between the range of 0 to 20 L/per./hr. during the measured period. Some cases the deviation was noticed more than 10 times higher than the average one however the probability of occurrence was very low. The frequency of consumption is important to design the system as well as making a connection with renewable energy sources. The frequency of DHW consumption for month of November is shown in table 2. Frequency 60% 40% 20% 0% 1 1 1 1 1 2 Consumption rate, L/per./hr

5.0 3.0 1.0 August November January Fig. 3 ly average consumption profile for month of August, November and January The hourly consumption during November was found higher compared to August and January. In addition, hourly consumption patterns were nearly similar for all the months. Because the average profile of a large group is dampened and smoother, hourly profiles for different group sizes were drawn in order to explain properly the hourly variations. The hourly profiles of small groups could able to estimate more preciously the consumption of any number of occupant. For instance if designers would like to design the DHW system for 7 occupants or 100 occupants, they could easily choose 10 person group or 191 person group profile respectively. In figure 4 is shown the proposed profiles of different groups for month of November. 1 1 1:00 2:00 4:00 5:00 6:00 7:00 8:00 9:00 10:00 11:00 12:00 1 14:00 16:00 17:00 18:00 19:00 20:00 21:00 22:00 2 0:00 191 Per. 31 Per. 10 Per. 3 Per. 1 Per. Figure 4: Proposed profiles of different groups for month of November In method section the selection criteria for each profile was described briefly. Selected candidates (most close to average daily consumption) of each profile group were compared to the pattern of average profile of 191

people. The candidates which had the best similarity with average profile were selected as representative ones for studied 5 groups. Similarity was assessed based on morning and evening peak ratios, peak times and durations which are the main parameters describing the shape of profiles. Daily consumption of selected candidates was scaled with daily average consumption for month of November (table 1) and individual factor was assigned for each hour of different group. Scaled hourly consumption factors of groups for month of November are shown in table 2. ly consumption values for each hour can be calculated from Table 1 and 2 data as follows: = 24, =, Where, m is month of year, i is hour during a day and g is group. The ratio of DHW to total water may be important information for energy calculations. The ratio of DHW to total water of November and hourly DHW ratio as a function of specific consumption are shown in figure 5. DHW ratio 0.45 0.35 0.25 R² = 0.2405 0.15 0.2 5 0.1 0 100 200 Consumption (L/person/day) (a) (b) Figure 5: (a) Ratio of DHW to cold water (total) (b) ly DHW consumption ratio as a function of specific consumption for month of November The common finding was a higher hourly consumption ratio during peak hours of the day. For lowest consumption hours the ratio was low. Most cases occupant used low volume of DHW for hand washing during that period. At that condition the initial water temperature are relatively cold while it starts to deliver but it adjust within couple of second. Furthermore, DHW ratio was not clearly dependent on hourly consumption of shown in the figure. DHW ratio 0.5 0.4 0.3

Conclusion ly DHW consumption rate was derived based on measured data from 86 apartments with 191 occupants. The following conclusion can be drawn Daily average consumption (L/per./day) was nearly similar to previous study. The average consumption pattern during a day had nearly similar pattern for August, November and January. DHW hourly consumption followed the lognormal distribution and consumption were in between 0-20 L/per./hour. Average consumption of peak and non-peak hour were 3.6 and 1.5 L/per./hour respectively. Five different group consumption profiles were derived to describe the hourly consumption as a function of number of occupants. Smaller group had a higher peak consumptions compared to larger groups. Derived profiles allow to design DHW systems for any number of occupant. The obtained profiles can be use with monthly consumption factors (Table 1) to generate the hourly profile of all months. An average DHW ratio was 0.31 but significant variance (0.10-0.39) was found during a day. Acknowledgment K.V. Lindholms Stiftelse foundation is acknowledged for financial support and Finnish Real Estate Federation Kiinteistöliitto for DHW data. References [1] J. Hakala, "Energy consumption in households 2014," Edita Publishing Oy, 2014. [2] "Water supply Statistics," Statistics Netherlands, Rijswijk, 2007. [3] "Suomen rakentamismääräyskokoelma osa D3," Rakennusten energiatehokkuus, Helsinki, 2003. [4] "Regelsamling för byggande BBR-2012," Sweden, 2012. [5] K. Ahmed, P. Pylsya and J. Kurnitski, "Monthly domestic hot water profiles for energy calculation in Finnish apartment buildings," Energy and Buildings, vol. 97, no. 15 June 2015, p. 77 85, 2015. [6] IEA, "Energy conservation in buildings and community systems programme" 2007. [7] E. Vine, R. Diamond and R. Szydlowski, "Domestic hot water consumption in four lowincome apartment buildings.," Energy, vol. 12, no. 6, p. 459 467, 1987. [8] E. J. M. Blokker, J. H. G. Vreeburg ja J. C. v. Dijk, Simulating Residential Water Demand with a Stochastic End-Use Model, Journal of Water Resources Planning and Management, osa/vuosik. 136, nro 1, 2010. [9] Suomen Rakentamismääräyskokoelma D1, Kiinteistöjen vesi-ja viemärilaitteistot Määräykset ja ohjeet, Helsinki, 2007.