SURNA REFLECTOR OPERATING AND MAINTENANCE MANUAL

Similar documents
Surna Dehumidifier Operating & Maintenance Manual

Surna Air Handler Unit Operating & Maintenance Manual

Surna 25-Ton Chiller Operating & Maintenance Manual

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

ion Genesis Pump Controller

Ozone + UV Sanitation

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

MaxLite LED Vapor Tight Linear Fixture

OKB, OKD, & OKH Series

Installation, Operation, and Maintenance Manual

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

MaxLite LED High Bay Fixtures

MaxLite LED Round Pendant Highbay Series

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

HotPoly Tote Tank / IBC Heaters (TTH Series)

MIGHTY PRO 1/4 HP CHILLER

Air Pump Up to 800 gallons

ARUBA SUN SERIES - LIGHTING SYSTEM USER MANUAL

Next Generation Corona Discharge Auto Voltage Sensing Installation Manual

User s Manual and Operating Instructions

Industrial Vacuums, Inc

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Torrena 42 Ceiling Fan

IMPORTANT SAFEGUARDS

Camarillo 52 Ceiling Fan

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

TOUCHDOWN 48 CEILING FAN

e Bath Fan with Light User s Guide

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

STEAM WALLPAPER STRIPPER MODEL HTW5

Operator s Manual. IP-100 Immersion Probe Cooler

(HSTAT Series) Instruction Manual

Operator s Manual. Histology Bath

A2Z Ozone, Inc. PRODUCT MANUAL

ST. KITTS CEILING FAN

Installation Guide. For Models: E-DCF52BNK5C3 E-DCF52FBZ5C3 E-DCF52MWW5C3 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

Installation Guide. For Models: E-MLV36BNK4LK1 E-MLV36ESP4LK1 E-MLV36WW4LK1 READ THESE INSTRUCTIONS AND AND SAVE THEM FOR FUTURE USE

User s Manual and Operating Instructions

Owner s Manual Compact Fluorescent Lunar Aqualight

P/N CC-100. Coolant Circulator. Operation manual

gamma pond Ultraviolet Sterilizers

Installation Guide. For Models: E-PD52ABZ5C4 E-PD52BP5C4 E-PD52WW5C4 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

INSTALLATION AND OPERATING INSTRUCTIONS FOR Built-in units Blt-in-38, Blt-in-58, Blt-in-36 & Blt-in-62

MaxLite LED MICRO-T PANEL

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

Owner s Manual. High Output T5 Lunar Aqualight. Aquarium Light Fixture. Featuring: Directional Lunar Blue LEDs

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

Power Pack Service Manual

DUST FREE CARBON Whole House Air Purifier

INSTALLATION AND USER INSTRUCTION GUIDE. Electric Fire With Remote Control. Model: WM-3522CF. Please read all instructions carefully and

nova extreme retrofit High Output T5 Lighting Kit

POWER PACK SERVICE MANUAL

SUTTON 52 CEILING FAN

Installation and Operation Instructions Luxury Towel Warmer Free Standing or Wall Mounted

Installation Instructions PP-AS20 Anti-Scale System

Drain Tempering Reservoir READ & SAVE THESE INSTRUCTIONS. Installation, Operation, & Maintenance. TRION

3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL. Model # 4KTV9

ELSTON 52 CEILING FAN

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

Installation Manual. Models 99168, 99169, 99170

52 BAYTOWNE CEILING FAN

Installation, Operation & Service Manual

TUBULAR LLdia-PUMPyy INSTRUCTIONS

THE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System)

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

SPRINGHILL 44 CEILING FAN

Pressurized Filter Up to 1250 gallons

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Industrial Dehumidifier Operating Instructions. Model: VG 1500

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

Instruction Manual. Bucket Oil Pump

EXPANDABLE 0.5W LED FRESHWATER LIGHT FIXTURES

Compact Equipment Warranty Policy

FLCH4R Garage and Utility Electric Heater

MN908 No. 282C Replaces 282B LB7013

OPERATION & INSTALLATION MANUAL

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

Prime Tower. Inline Chiller. Instructions for Models #2645,2646

LIMITED LIFETIME WARRANTY

CF SERIES CF100 CF200 CF300

IMPORTANT SAFETY INFORMATION:

INSTALLATION, OPERATION AND MAINTENANCE

Owner s Manual Phoenix Aquadry TX 200

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

52 CEILING FAN. Owner s Manual Models #50336, 50337

60In. Ceiling Fan. Owner s Manual

52 SAN LUCAS CEILING FAN

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

R Series B & T2 Model

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

Quest PowerHeat HFC 100 Pro

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

Transcription:

SURNA REFLECTOR OPERATING AND MAINTENANCE MANUAL Models: 1-REF-03, 1-REF-01 August 2017 surna.com

TABLE OF CONTENTS Specifications 4 Warnings 6 Warranty Information 8 Installation Instructions 10 Routine Maintenance 15 3

SPECIFICATIONS PHYSICAL VENTED 1-REF-03 LIQUID-COOLED 1-REF-01 Length 32 in Width 33 in Height 13 in 18 in Weight 40 lbs 59 lbs ELECTRICAL Voltage 120/240V Amperage 9.1 A at 120V / 4.5A at 240V Wattage (DE) 1000W Frequency 60Hz PERFORMANCE Nominal Capacity NA 1.5 GPM Total Capacity NA 0.5 Ton Sensible Capacity NA 0.4 Ton Entering Water Temperature NA 45 F Leaving Water Temperature NA 45 F Glycol Type & Percentage NA Propylene Glycol - 10 to 50% Temperature Sensor Pane 10395 Pressure Drop NA 0.45 psig ADDITIONAL INFORMATION ( APPLIES TO ALL MODELS) Optimal Reflector Height 24 in to 36 in above canopy Recommended Grid 4 x 4 ft ; 4 x 5 ft ; 5 x 5 ft Ballast Placement Mounted above reflector on structure or ceiling Light Control Locally connected by day/night times Fan Control Surna s Smart Control System for maintaining zone temperatures 4

5

WARNINGS DEFINITIONS CAUTION: Risk of minor/moderate injury if precaution not taken. REFLECTOR SAFETY GUIDE WARNING: Risk of death/serious injury if warning isn t heeded. DANGER: Risk of death/serious injury if danger isn t avoided. SAFETY SYMBOLS USED CAUTION: Important information, read the provided instructions carefully WARNING: Potential electric shock hazard WARNING: High voltage Please read the information in this document carefully prior to attempting the installation, operation and/or servicing of the reflector. This document contains all information required to install and operate the Surna reflector. Failure to follow the directions provided herein may impair the safeties provided and could cause damage to the equipment, damage to building facilities, and/or cause serious injury or death to the operator. Please adhere to all applicable safety guideline requirements in this document and all applicable electrical and mechanical jurisdictional codes. WARNING: Cut/Crush hazard Protective earth connection Action prohibited Prior to providing power to the equipment, inspect the area for water spills, which may present a shock hazard to the user. Take extra care to mount accessory electrical equipment away from areas regularly exposed to water and provide secure wire and cable routing to protect personnel from shock hazards. Only operate the equipment with an appropriately sized breaker in place and wire sizes with adequate current carrying capacity. Consult with an electrician before attempting electrical installation. 6

Using Surna Reflector equipment in a manner not described in this manual may void its warranty and any safeties provided herein. DO NOT use Ethylene Glycol with this system. Only Propylene Glycol is to be used at prescribed mixture ratio of atleast 30% propylene glycol. Following unit installation and maintenance activities, the user shall observe the system operation to verify that normal operation has resumed prior to letting the equipment operate unattended. Only use Surna supplied or recommended equipment with the reflector. The ballast and bulb used in the end application shall be separately certified for safety in the country of use. This unit must be connected to a protective earthing system prior to operation. DO NOT remove the grounded connection while power is being supplied to the Surna reflector equipment. Doing so presents an electric shock hazard to users and service personnel. Care must be taken when handling sheet metal. Sheet metal parts have sharp edges and could cause injury. The components of this reflector assembly have been inspected at the factory and readied for shipment. Upon receiving the shipment a visual inspection of the packaging must be performe,d. 7

WARRANTY INFORMATION Equipment manufactured by Surna ( Company ), the warranty shall exist for a period of twelve (12) months from initial start-up or eighteen (18) months from date of shipment, whichever period is shorter, against failure due to defects in material and/or manufacturing and warranted to the capacities and ratings set forth in Company s catalogs and bulletins ( Warranty ). Equipment, material, and/or parts that are not manufactured by Company are not warranted by Company and carry such warranties as may be extended by the respective manufacturer. Exclusions from this Warranty include damage or failure arising from: wear and tear; corrosion, erosion, deterioration; modifications made by others to the Equipment; repairs or alterations by a party other than Company that adversely affect the stability or reliability of the Equipment; vandalism; neglect; accident; adverse weather or environmental conditions; abuse or improper use; improper installation; commissioning by a party other than Company; unusual physical, electrical or mechanical stress; lack of proper startup or maintenance as recommended by Company; operation with any accessory, equipment or part not specifically approved by Company; and/or refrigerant not recommended or supplied by Company. (f.o.b. factory or warehouse for US domestic purposes) at Company-designated shipping point, freight allowed to Company s warranty agent s stock location, for all non-conforming Company manufactured Equipment which have been returned by Customer to Company. Returns must have prior written approval by Company and are subject to restocking and replacement charges where applicable. No warranty liability whatsoever shall attach to Company until Customer s complete order has been paid for in full and Company s liability under this Warranty shall be limited to the purchase price of the Equipment shown to be defective. Additional warranty and service protection is available on an extra-cost basis and must be in writing and agreed to by an authorized signatory of the Company. The warranty excludes: (a) labor, transportation and related costs incurred by the Dealer or Customer; (b) re-installation costs of repaired equipment; (c) reinstallation costs of replacement equipment; (d) removal costs of equipment; (e) consequential damages of any kind; and, (f) reimbursement for loss caused by interruption of service. Company shall not be obligated to pay for the cost of lost refrigerant or lost product or any other direct, indirect, or consequential damages. Company s obligations and liabilities under this Warranty are limited to furnishing replacement equipment or parts, at its option, FCA (Incoterms 2000) factory or warehouse EQUIPMENT MANUFACTURED BY COMPANY THAT INCLUDES A REQUIRED START-UP AND SOLD IN NORTH AMERICA WILL NOT BE WARRANTED BY COMPANY UNLESS COMPANY OR ITS AUTHORIZED AGENT PERFORMS THE EQUIPMENT STARTUP. COMPANY MAKES NO REPRESENTATION OR 8

WARRANTY, EXPRESS OR IMPLIED, REGARDING PREVENTION OF MOLD/MOULD, FUNGUS, BACTERIA, MICROBIAL GROWTH, OR ANY OTHER CONTAMINATES. EXCEPT FOR COMPANY S WARRANTY EXPRESSLY SET FORTH HEREIN, COMPANY DOES NOT MAKE, AND HEREBY EXPRESSLY DISCLAIMS, ANY WARRANTIES, EXPRESS OR IMPLIED CONCERNING ITS PRODUCTS, EQUIPMENT OR SERVICES, INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF DESIGN, MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE, OR OTHERS THAT ARE ALLEGED TO ARISE FROM COURSE OF DEALING OR TRADE. REFLECTOR ORDER Below is a list of all parts provided with each Surna Reflector. The following are included with the order (quantities are dependent on individual order). 1. Fan power supply 2. Fan patch cord NECESSARY ACCESSORIES Below is a list of necessary accessories not included with each Surna Reflector. All models: 1. Bulb 2. Ballast, rated for 1000W maximum 3. Mounting chain (2) 4. Ball valves (2) 5. Rubber gloves 6. Lens tissue or paper towel Liquid-cooled model: 1. Fan controller 2. Tubing for liquid cooling and condensate circuit 3. Flowmeter 4. 1/2 inch (1.27 cm) copper-to-pex SharkBite fittings All models: 1. Surna Reflector 2. Surna Reflector product manual 3. Accessory kit a. Quartz Tube b. Quartz Tube mounting brackets c. S-hooks d. 1/8 inch Allen key Vented model: 1. MERV-12 air filter Liquid-cooled model: 9

INSTALLATION INSTRUCTIONS MECHANICAL This reflector unit is designed for installation in a level, horizontal orientation onto either a ceiling or other suitable support member. The weight information for each model can be found in the specifications section of this document. Care must be taken to ensure the structural integrity of the supporting members and mounting hardware which should be rated appropriately to support the reflector's weight. When installing, clearances must be provided as a provision to allow servicing of the unit. If installing a liquid-cooled version, ensure that adequate space is available to facilitate servicing of the fan, water connections, and condensate ports. Each unit is provided with mounting hardware that can be connected to a chain or other suitable hanging device. Verify each unit is in a level orientation, centered over the target area. This reflector was designed for optimum photometric performance with the glass surface mounted at a distance of 24 inches (61 cm) above the plant canopy. ELECTRICAL LIQUID-COOLED MODEL To make the fan connection, plug the provided patchcord into the reflector assembly 3-pin connector located above the end plate opposite the water connections. Plug the provided AC/DC adapter into the patch-cord and plug the AC/DC adapter into a standard socket outlet and verify that the fan is operating normally. PLUMBING - LIQUID-COOLED ONLY Ball valves should be used on the supply and return plumbing connections so that the unit may be isolated at any time for maintenance or service. To complete the plumbing circuit, use ½ inch (1.27 cm) PEX tubing and ½ inch (1.27 cm) Copper-to-1/2 inch (1.27 cm) PEX Sharkbite fittings to connect to the ball valves installed on the manifold. If the reflector distance to canopy will ever change, lower the reflector to its lowest position before installing plumbing. All wiring shall comply with local and national codes. Attach the reflector to an appropriate ballast for Double-Ended High-Pressure Sodium bulbs rated for 1000 W (max) using the ballast cord that is attached to the reflector assembly. The ballast in use shall be appropriate for the application and shall be installed according to the manufacturer s instructions. Make sure that a loop is in the PEX lines so that there are no complications in the plumbing lines as the reflector is moved up and down. Using ½ inch (1.27 cm) flexible tubing, attach the condensate drain lines to the provided hose barbs and secure with clamps. Connect the condensate lines to either a water reclamation reservoir, or to the desired waste location. 10 Apply coolant flow and verify that no leaks are present. This unit was designed for 1 Gallon Per Minute (GPM) of coolant flow.

WARNING: Temperature of the coolant should not be lower than 65 F (18 C), or exceed 90 F (32 C). WARNING: Water circuit must be leak tested prior to applying power to the bulb or fan. WARNING: DO NOT attempt to access the reflector interior while power is applied to the unit. IMPORTANT PUMBING TIPS Total manifold size and length will vary depending on specific circumstances, number of reflectors, etc. Choose a supply size that is sufficient for the flow rates of all equipment supplied by the manifold. The return manifold should be sized a minimum of ¼ inch (0.64 cm) larger than the supply manifold. Install shut off valves at the main supply manifold and a shut off valve at each reflector. This allows individual units to be taken out of the cooling loop should servicing be necessary. Install a fresh water bypass on the main supply manifold. This allows use of a municipal water supply for cooling should thechiller require servicing. Only long turn 90 s (piping) should be used whenever possible to avoid restriction of the water supply. Flow rate requirements for these reflectors is 1.0 GPM (Gallons Per Minute). Chiller temperature should not be lower than 45 F (7 C). DO NOT use Ethylene Glycol (standard car antifreeze) with this equipment. When plumbing is complete, start the system with clean water to flush out all residue from the system and to check the water circuit(s) for leaks. Run for approximately 5 minutes and then drain the water from the system, correcting and retesting leaks as necessary, and refill with the prescribed glycol/water mixture. Turn on the system and top off the reservoir as needed. 11

WIRING DIAGRAM 120/240 AC Bulb Power Ballast 120 AC Fan Control High Voltage Wire Low Voltage Wire Surna Reflector Figure 1- Wiring diagram for the Surna reflector 12

SET-UP INSTRUCTION Step 1: Unbox Reflector Step 2d: Mount bulb into sub-reflector Unbox the Surna Reflector and inspect for damage. Thoroughly inspect the glass and wings for any visible damage. Open Accessory Box and inspect for damage, ensuring the Quartz Tube is intact. Slide the lamp holders on either end of the sub-reflector assembly away from one another to create space in which to place the quartz tube assembly. Step 2e: Assemble sub-reflector & bulb Step 2: Install bulb The Surna reflector has been designed for two types of bulbs - DE HPS or CMH. Please consult the instruction manual as to which model you have purchased. Place reflector on hard, steady surface, such as a work bench, with the glass surface facing down. Step 2a: Remove access panel Remove access panel with 1/8 inch Allen key (included in accessory kit). Access panel is located opposite the water connections. Step 2b: Remove sub-reflector Mount the bulb and quartz tube assembly in the subreflector assembly by using one hand to hold the bulb in place and the other hand to slide the lamp holders towards the center of the bulb until bulb is secure. Verify that both bulb and quartz tube are free from fingerprints and/or contamination. Step 2f: Place sub-reflector Slide sub-reflector assembly into the middle of the fixture and insert power cord into the mating receptacle located on the upper wing surface of the reflector. Reattach end plate using 1/8 inch Allen key. Step 3: Hang reflector Remove the sub-reflector assembly from the reflector by unplugging the subreflector assembly power cord, securing the assembly with two hands and sliding out through the access panel. Step 2c: Assemble quartz tube To protect the bulb and quartz tube from fingerprints and oils, use a lens tissue and rubber gloves. Place bulb inside the quartz tube and slide the metal brackets onto either end of the bulb and mate with the inside of the quartz tube. Use the eye hooks, S-hooks, and mounting chain to hang the unit from the supporting member. The support should be rated for a minimum of 70 lbs. Step 3a: Measure & level reflector Hang, with the bottom of the Reflector (glass surface), 24 inches (61 cm) from the desired canopy height, centered over the 4 foot x 4 foot (1.2 m x 1.2 m) target area. Use the bubble levels found on the Reflector to ensure that the Reflector is hanging in a level position. On liquid-cooled models, ensure the reflector is not slanting away from the condensate drain connections. 13

Step 4: Install flowmeter (recommended) LIQUID-COOLED MODELS ONLY Install flow meter (not included) according to manufacturer s instructions. Place the flow meter on the hot water return line. Step 5: Install plumbing LIQUID-COOLED MODELS ONLY Install cooling circuit with the reflector hung at its lowest point. Install PEX plumbing allowing for a loop in the tubing - making for smooth raising or lowering of the reflector. For ease of service, use ball valves on the supply and return lines. Using 1/2 inch (1.27 cm) PEX tubing, attach Reflector to coolant supply and return manifolds with 1/2 inch (1.27 cm) Copper-to-1/2 inch (1.27 cm)-pex Shark-Bite type connectors. Step 5a: Install Condensate Lines LIQUID-COOLED MODELS ONLY 65 F (7 to 18 C). The lowest recommended coolant temperature for best operation is 45 F. If leaks are identified, shut off water flow, isolate the unit using the installed ball valves, repair leaks and retest. If you would like to use a lower coolant temperature with the Surna Reflector, please contact the Customer Support team at supposrt@surna.com or 303-993-5271 for further information and instruction. Step 7: Install fan power Connect the fan patch cord to the fan power port on the reflector (6 pin round connector). Step 7a: Connect fan power Connect the supplied AC/DC power supply adapter unit to the fan patch cord. Connect the AC/DC power supply adapter to a standard wall outlet. Fan should turn on once power is applied, verify for correct operation. Using ½ inch (1.27 cm) flex tubing, attach condensate drain lines to provided hose barbs and secure with clamps. Connect the oppositeend of the condensate drain lines to a water reclamation reservoir or to the desired waste location. Before applying power to the equipment, coolant flow should be applied to the unit and a leak check should be performed. The flow rate should be 0.25-1.0 gallon per minute (GPM). This unit was designed for a maximum of 1.0 GPM. Step 6: Test plumbing LIQUID-COOLED MODELS ONLY Verify that coolant source (chiller, cooling tower, etc.) is providing coolant with a temperature range of 45 to 14

ROUTINE MAINTENANCE This product is designed to provide many years of dependable, trouble free comfort when properly maintained. Proper maintenance will consist of routine filter inspections/changes, water connection inspection (liquid-cooled reflectors), bulb replacement, window cleaning, and reflectance material changing. Failure to provide periodic check-ups and cleaning can result in excessive operating cost and/or equipment failure. For guidance on routine maintenance activities, contact Surna support. CONTACT US Contact Surna via email at support@surna.com or via phone at 303.993.5271. 15

A P E 1780 55th Street, Suite A Boulder, CO 80301 303.993.5271 info@surna.com surna.com