Rick Seidel Fike Corporation Regional Sales Manager

Similar documents
FIRE SUPPRESSION SYSTEM

Fire suppression systems for server rooms and data centres

BOC FS125 The Fire Extinguishing Solution

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Water Mist Fire Suppression

Watermist Systems. Versatile, Affordable Water Mist Fire Suppression. your TRUSTED partner in fire safety

WATER MIST CONVENTION AND EXHIBITION

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

Fire protection for buildings

ODS & SGG Alternatives for the Fire Protection Industry 2018

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE

Nessie High Pressure Water Mist Components for Fire Fighting

An Overview of Extinguishing Systems for Computer Equipment

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

STANDARDS FOR ACTIVE FIRE PROTECTION. Stewart Kidd Loss Prevention Consultancy Ltd

The Science Behind Water Mist Protection of Typical Building Hazards

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

How can I protect invaluable assets and the environment from the effects of a fire?

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

SECTION FM-200 FIRE SUPPRESSION SYSTEM

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

WAS STARTED BY CARLOS BAHAMONDES MASAFIERRO

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

What is HI-FOG? The natural enemy of fire

The metering orifice is sized according to the type and percentage of concentrate used and is also secured with a stainless steel retaining ring)

PHIREX AUSTRALIA. FOGEX & MISTEX WATER MIST FIRE PROTECTION

KD Innovative extinguishing with Novec TM 1230 by 3M TM

Superior by Design The Kidde ADS TM FM-200 System

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

Performance Based Fire Protection With Water Mist

VELMIST. System Mgły Wodnej Niskociśnieniowej

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

Safe, Effective, Environment-friendly

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

CO2 COCO GAS FLOODING SYSTEM

HFC-227ea FIRE SUPPRESSION SYSTEM

CONTENTS. bawa-speci, Ver Maintenance. 1. INTRODUCTION: 1.1 bawa-speci Version 01

How can you minimize consequential damages in case of a fire?

MORE THAN JUST FIRE PROTECTION

FIRE PROTECTION, NATURALLY AQUASONIC Water-Atomizing Fire Suppression System

MINIMAX FIRE PRODUCTS WHITE PAPER THE COST-BENEFIT ADVANTAGES OF REPLACING HALON WITH 725 PSI MX 1230 CLEAN AGENT FIRE SUPPRESSION SYSTEMS

What extinguishes fires without pressure peaks?

Safer. Smarter. Tyco. I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker.

Element C3.4 Fire Fighting Equipment

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

Explosion Protection of an Armoured Vehicle Crew Compartment with Water Mist. Andrew Kim and George Crampton

MORE THAN JUST FIRE PROTECTION

Jonathan Redding Area Sales Manager FOGTEC Fire Protection Cologne, Germany

GX-20/FM-200 Fire Extinguishing System

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

Welcome to Argonite fire protection from Ginge-Kerr

Watermist Applications and Approvals

Carbon Dioxide Fire Suppression Systems

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

Water Mist Fire Protection Systems for the Protection of Industrial Oil Cookers. 8th March 2016 Dr Tim Nichols CPhys MIFireE

Fire Protection in the Mining Industry. Garry Kwok Board Member

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

SPECIFICATION: ARGONITE Engineered Fire Suppression System

SUPPRESSION SALES I INSTALLATION I SERVICE

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

FOREFRONT AT THE OF PROTECTION

PHIREX AUSTRALIA CATALOGUE & DATA SHEETS. April 2005, Rev 2. Fogex Water Mist Fire Protection System Components PHX-3064

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

What provides highly reliable fire protection?

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

SAPPHIRE. Gaseous Fire Suppression Systems. Delivering 3M Novec 1230 Fire Protection Fluid

Fixed Fire Suppression. Protec. Protec Fire Detection plc. Fixed Fire Suppression Solutions ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

esfr dry pendent sprinkler Vk502 (k14.0)

Fire Extinguishing Agents for Protection of Occupied Spaces in Military Ground Vehicles

High flying fire protection HI-FOG for aircraft hangars

Certificate of Conformity Certificate num. Registration date Version Valid until

CARTRIDGE EXTINGUISHER

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

DuPont FE-25 FIRE EXTINGUISHANT. Preferred Replacement for Existing Systems and the Choice for New Applications

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

tyco Fire & Safety RESEARCH VESSEL - NEW ORLEANS

standard response elo upright sprinkler

Mitigating Fire Risks in Mission Critical Facilities

CLEAN AGENTS & CLASS C FIRE HAZARDS

Specialists in Tunnel Fire Protection

Factors Affecting Efficiency of Water Mist Suppression of Solid Combustible Fires in Open Environment

GASEOUS HYDROGEN SYSTEMS

CHAPTER THREE SPRINKLER SYSTEM AND FM-200 AGENT SYSTEM

Hospitals and Major Medical Centers

Model MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)

Certificate of Conformity Certificate num. Registration date Version Valid until

AMENDMENT NO. 1 TO IS 2878:2004 FIRE EXTINGUISHER, CARBON DIOXIDE TYPE (PORTABLE AND TROLLEY MOUNTED) - SPECIFICATION

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Fire Safety Compliance

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

IT AFEM. Table of Contents. Error! Table not allowed in footnote, endnote, header, footer, comment, or text box.

Transcription:

POWER & ENERGY SOCIETY INDUSTRY APPLICATIONS SOCIETY LIFE MEMBERS AFFINITY GROUP NEW YORK SECTION INNOVATIONS IN FIRE PROTECTION DESIGN FACTORS TO CONSIDER FOR TODAY S PRACTICES Rick Seidel Fike Corporation Regional Sales Manager

Agenda Inert Gas Fire Suppression Clean Extinguishing Agent Evolved Enhancements Advantages Watermist Fire Suppression

Definition of a Clean Extinguishing Agent As Defined by NFPA 2001, Standard on Clean Agent Fire Extinguishing Systems Electrically nonconducting, volatile, or gaseous fire extinguishant that does not leave a residue upon evaporation.

Clean Extinguishing Agents Mission Critical Protection Asset Protection Minimizes Downtime Safe for People and Assets Non-Conducting No Residue Space Efficient 3-Dimensional Fire Fighting Back to business..

Why Not Water? Sprinkler flow time of 30 minutes Each sprinkler discharging 18 to 35 gpm of water That s 540 to 1,050 gallons of water on your valuable assets! Discharge of two sprinkler heads is common that s 1,080 to 2,100 gallons of water!!

Fire Extinguishment vs. Fire Control

Clean Agent Systems Primary Advantages Ability to extinguish shielded, obstructed, 3-D fires Provide rapid extinguishment Significantly reduces collateral Smoke and water damage caused by delayed extinguishment and Sprinklers Odorless, Colorless, No residue left behind

Clean Agent Fire Protection

Halon 1301

Halon 1301 Agent Characteristics. Chemical name Bromotrifluoromethane Vapor Pressure 235 psi Molecular Weight 148.9 Boiling Point -72 F Design Concentration, occupied spaces 5% - 7% Global Warming Potential 6,290 Ozone Depleting Potential 16 Safe for Occupied Spaces? YES!

Clean Extinguishing Agents Halon 1301.. Production Ceased in countries that signed the Montreal Protocol in 1994 Ozone Depletion No longer sold for new systems Only sold as recycled / reclaimed agent that is used for recharging systems Thousands of systems remain in service, with many users actively seeking replacement due to: Corporate Environmental Initiatives Long-term Supply Availability Cost of Replenishment

NFPA 2001; Present Day Commercially available agents HFC-227ea (FM-200, FE-227) HFC-125 (FE-25, ECARO-25) HFC-236fa (FE-36) IG-55 (Argonite, ProInert) IG-541 (Inergen) FK-5-1-12 (Novec 1230, Sapphire) Most Common Halon 1301 Replacements

Two Categories of Clean Agents Man-Made Agents Naturally Occurring Gases Zero-Ozone Depleting LOW- Global Warming Potential (GWP) Waterless Flash Gases - FM-200 1994 - ECARO-25 2003 Fluids Fluoroketones - Novec 1230 2005 Zero-Ozone Depleting Zero-Global Warming Potential (GWP) Inert Gases - 1 st Generation: Inergen 1994-2 nd Generation: ProInert2 2009 - Agronite

100% Green Fire Protection Inert Agents Argonite

. Launched in 1994 by Ansul. Is a mixture of three natural occurring gases: Nitrogen, Argon & Carbon Dioxide. Environment-friendly, people-safe agent with ZERO ozone depletion potential, ZERO global warming potential, and ZERO atmospheric lifetime.

Inert Gases Extinguish a fire by reducing the residual oxygen concentration to a level that will no longer support combustion, but will still sustain human existence.

Agent Characteristics. Chemical name Mixture of Inert Gases & Carbon Dioxide 52% N2, 40% Ar and 8% CO2 ASHRAE Designation IG-541 Molecular Weight 34 Boiling Point -320.8F Design Concentration, occupied spaces 38.5% - 52% Maximum Human Expose Time up to 43% is 5 minutes Maximum Human Expose Time 43 to 52% is 3 minutes Ozone Depletion Potential - 0

. ProInert2 was launched in to the US market in 2008 by Fike. Inert systems for Fike make up 90% of their clean agent fire systems sold in Europe. ProInert2 does not use CO2 in its mixture. IG-55 is the same mixture as you will find in Argonite.

What Is ProInert? Inert Gas Fire Extinguishing System Extinguishes Fires by Oxygen Reduction Gas stored as a compressed gas/vapor Extinguishing Gas IG-55 = 50% Ar / 50% N2 IG-541 = 50% AR / 40% N2 / 10% CO2

Agent Characteristics. Chemical name - N 2 /Ar (50% - 50% blend of Nitrogen & Argon) ASHRAE Designation IG-55 Molecular Weight 33.95 Boiling Point -310.2F Design Concentration, occupied spaces 39% - 52% Maximum Human Expose Time up to 43% is 5 minutes Maximum Human Expose Time 43 to 52% is 3 minutes Ozone Depletion Potential - 0

ProInert 2 - Storage Footprint Traditional Inert Systems: Up to 40% less Reduced Storage

Safe for People ProInert is completely safe for use in occupied spaces. P/N: 06-384-1 rev. -

What does 12.7% Oxygen Mean to You? Pikes Peak, Colorado - Most visited mountain peak in North America - Elevation = 14,110 feet above sea level = 12.2% NFPA and UL minimum allowable design concentration for egress = 10%

Benefits: Equipment and installation costs close to other clean agents Similar maintenance costs to other clean agents Full height walls not an issue Remote agent storage capability up to 200 away Upgrade Any Existing Halon or Clean Agent System Utilizing All Original Piping Low refill costs Inert Agents

Agent Comparisons Man Made Agents Inert Gas Need: (7) Of IG-541 (6) of IG-541 (6) of IG-541 (4) Of PI2 (3) of PI2 (3) of PI2

Complete System Cost Comparison 150 K = Vortex/ Marioff 100K = Fike DQ 150K 68K 47K 45K 43K 39K

Agent Comparisons Agent ASHRAE Molecular Weight Global Warming Potential Boiling Point Concentration % Ozone Depletion Halon 1301 n/a 148.9 6290-72 F 5 7% 16 FM-200 HFC-227ea 170.3 3350 2.5 F 6.25 10.5% 0 ECARO -25 HFC-125 120.2 3170-54.7 8 11.5% 0 Novec FK-5-1-12 316.04 <1 120.6 F 4.5 6% 0 Inergen IG-541 34 0-320.8 F 38.5 52% 0 Argonite IG-55 33.95 0-310.2 F 39 52% 0 Carbon Dioxide CO2 44 1-109.3F 34% + 0 Air 29 0-319F 0

What About Pressure Displacement During An Inert Gas System Discharge?

Pressure Venting Inert Agents displace the oxygen in the room. Pressure venting is required to avoid overpressurizing the room. If you forget to do it, the system has a built in method of correcting the problem

Fike s ProInert system is the only system that uses a constant flow rate valve that discharges the agent at a constant low pressure (645 psi / 42 bar) over the required 60 seconds discharge time. Other systems have an aggressive initial discharge, and then decrease flow over time. This can lead to room and equipment damage, and does not extinguish a fire any faster than Fike s steady flow system.

Inert Gas Systems IG-541 Inergen IG-55 Argonite IG-55 ProInert IG-55 ProInert 2 Storage PSI 150 Bar 200 Bar 200 Bar 200 Bar 300 Bar Discharge PSI 2175 PSI 2900 PSI 2900 PSI 645 PSI 645 PSI Pressure Reducer Orifice Plate Orifice Plate Fike Patented Modulating Valve Fike Patented Modulating Valve Minimum Nozzle PSI 150 Bar 325 PSI 200 Bar 375 PSI 200 Bar 430 PSI 116 PSI 116 PSI An important advantage of ProInert is the lower pressure at discharge, which allows for a controlled flow of gas into the room to extinguish a fire it can also result in lower cost (lower pressure) piping, fewer nozzles, and smaller venting requirements compared to other inert gas systems.

Pressure (pa) Pressure (pa) Natural Agents Discharge Room Pressure 1st Generation Natural Agents Room Pressure 1000.00 900.00 800.00 700.00 600.00 500.00 400.00 300.00 200.00 100.00 0.00 0 10 20 30 40 50 60 70 Time (sec) 900-950 Pa=19-20 PSF 1000.0 900.0 800.0 700.0 600.0 500.0 400.0 300.0 200.0 100.0 0.0 ProINERT 2 Room Pressure 0 10 20 30 40 50 60 70 Time (sec) <400 Pa= 8.35 PSF Wall Strength Specs: 250 Pa (5 PSF) 2x4 walls 16 OC 500 Pa (10 PSF) 2x6 walls 16 OC Venting Requirements

What are the Advantages of the Fike valve? All piping used in the system from the cylinder to the nozzle is the same as used in chemical systems, Schedule 40 piping and 300 pound fittings Competition s inert gas systems require the use of Schedule 160 piping before their required pressure reducing orifice plate and Schedule 80 piping above 2 ½ throughout system. Competition fittings are 2,000 or 3,000 forged steel before their required pressure reducing orifice plate Significant savings on installations because of: Lighter scale piping requirement Greater flexibility with piping networks configuration and length

No limitations apply to the following: Design Factors a. If nozzles are only located above the cylinder outlet, the maximum elevation difference between the cylinder outlet and the farthest horizontal pipe run or discharge nozzle is unlimited. Maximum Elevation b. If nozzles are Differences only located below the cylinder outlet, in the Pipe maximum Runs elevation difference = UNLIMITED between the cylinder (Old Limit = 20.4 ft.) MAXIMUM ELEVATION DIFFERENCES IN PIPE RUNS The maximum elevation difference between horizontal pipe runs or nozzles is unlimited from the agent supply. outlet and the farthest horizontal pipe run or discharge nozzle is unlimited. c. If nozzles are located above and below the cylinder outlet, the maximum elevation difference between the cylinder outlet and the farthest horizontal pipe run or discharge nozzle is unlimited. No Limit No Limit No Limit System with a single level of Nozzles System with multiple levels of Nozzles System with ceiling and sub-floor Nozzles

Design Factors Now you can do this... 6 th Floor 2 nd Floor 1 st Floor Basement

Why Not Water Mist?

Water Mist Overview: What is Water Mist? Extinguishes fire using a very fine water spray with droplets <1,000µm. The fine droplets; cools the flame, displaces O² with water vapor and reduces radiant heat. Designated for use in Class A: Combustible materials (wood, paper, fabric, refuse), Class B: flammable or combustible liquids as the fuel source., and some Class C: electrical hazards; such as transformers (in enclosures). Class A requires larger droplets to help penetrate fuel source (fuel wetting). Class B requires finer droplets to avoid agitating fuel surface. First systems approved, aimed for smallest droplet size, high pressure. Newer, low pressure systems have obtained FM approvals with larger droplet sizes at much lower pressures.

Water Mist Overview: Droplet Size A larger droplet is more effective at penetrating down into the fire plume (Fuel Wetting) using its momentum (= mass x velocity) Small droplets do very well in small spaces, smaller the space the better the droplets can be directed to the fire. The larger the space gets the small droplet now gets difficult to control, it loses velocity as soon as it leaves the nozzle, it then does not know where to go. Smaller droplets means smaller waterways within the nozzle, now the water quality and impurities become extremely important.

Water Mist Overview: Concepts * 3 Main Concepts/Functions: 1. Inerting 2. Cooling 3. Fuel wetting All three are very important. Inerting = Oxygen Displacement Cooling = Heat Extraction Fuel wetting = Blocking of Radiant Heat, preventing the fire from propagating. Droplet size impacts the relative presence of each effect * Different Fires require different amounts of each element!

Water Mist Overview: Droplet Size Smaller Droplet: More efficient vaporization, cooling and inerting. SWEET! Where s the sweet spot? Larger Droplet: More efficient fuel wetting. Storage applications. 10 µm 100 µm 300 µm 400 µm 1,000 µm Water Mist Nozzle 300 µm gives the droplet the best of both efficient vaporization and fuel wetting. Sprinkler Heads

Water Mist Overview: Benefits As the water mist turns to steam, it expands immensely (1700 times) forcing oxygen away from the flame. Takes the energy out of the fire. Water mist incorporates a smoke scrubbing element. Provides extinguishment, not control. Provides 3D fire protection. Only need about 6-8 psi bar inlet pump pressure (wet pipe system), this is an estimate as the amount is determined by the Net Positive Suction Head Required (NPSHR) for the pumps plus our manual s safety margin of 2 psi. (Deluge system needs 29psi to keep the valve shut). Uses up to 80% less water than sprinklers (deluge app), and 50% less water than sprinklers (Light Hazard app).

Water Mist Overview: System Types High Pressure A water mist system where the distribution system piping is exposed to pressures of 500psi or greater and up to 2000psi. Uses ultra-high pressure pipe, fittings, & valves. Low Pressure A water mist system where the distribution piping is exposed to pressures 175psi or less. Uses standard pipe, such as Sch 40 SS, plus Class 150 300psi fittings. Fixed Supply Driven through system by N 2 pressure Must be refilled after discharge System cannot fight against any possible reignition of fire. Continuous Supply Uses building water supply Driven by pump Unlimited discharge time

Water Mist Overview: System Design No universal design method is recognized for water mist protection systems. Fike s design is different from others. Design & install in accordance with each manufacturer s Design, Installation, Operation, and Maintenance Manual (DIOM), requirements of FM Global (where applicable), NFPA Standards (750), and the requirements of the AHJ.

DuraQuench Benefits: Simplicity vs:

Versatile, Affordable Water Mist Fire Suppression LOWER OPERATING PRESSURE 175 psi versus 2000 psi MORE PIPE & FITTING OPTIONS Easily sourced pipe, fittings, and tools Stainless steel, copper, CPVC SIMPLE LAYOUT & DESIGN Use any hydraulic flow-calc software STANDARD FIKE LEAD TIMES Made from readily available components FM APPROVED, NFPA-750 COMPLIANT WATER Only need 6-8 psi inlet pump pressure 50-80% less water than sprinkler

Pump Controller

DuraQuench Benefits: Largest Machinery Space & Turbine Enclosure Approved Volume Company Maximum Approved Room Volume Max Ceiling Height Fike - DuraQuench 162,801 ft 3 39.4 ft Marioff HI-FOG GPU 53,000 ft 3 32.8 ft HI-FOG MT4 Water Mist System 48,600 ft 3 36.1 ft Tyco - AquaMist 45,203 ft 3 26 ft. 3 in FOGTEC Water Mist System 9,535 ft 3 Not available HI-FOG MT4 Water Mist System 48,600 ft 3 36.1 ft Securiplex - FIRE-SCOPE 5000 42,380 ft3 36 ft Not FM Approved for insulated turbines. TomCO2 Fogex System 17,657 ft 3 Not available

Deluge Systems in Industrial Applications Wet Pipe Systems Commercial Applications

DuraQuench Deluge: System Info Utilizes Open Nozzles. Total Flood. Piping network is empty (open to atmosphere) from the system deluge valve to the nozzles during normal system operation. Water supply is held back by the deluge valve. Deluge valve is opened automatically through the activation of the solenoid installed on the valve trim in response to the activation of the fire detection system installed in the protected area. Simultaneously, the detection system activates the fire pump sending pressurized water through the piping network to the open nozzles. ONLY Stainless steel Sch 10 and/or Sch 40 pipe can be used along with Class 150 (300psi) threaded fittings.

DuraQuench Deluge: Zoned System

DuraQuench Deluge: C-EL Control Valve 2 = 46 lbs.(20.8 kg) 3 = 74 lbs. (33.6 kg) Weight Used as a full flooding deluge valve or as a zone valve. 29 psi needed to keep closed. Working Pressure 232 psi maximum 29 psi minimum Factory Tested Pressure 348 psi maximum Materials Stainless Steel, ANSI 316L Gasket Materials EPDM Pressure Gauge Locations Valve Inlet and Primary Valve Outlet Activation Options Manual Release Lever Electric Impulse Solenoid (24 VDC, 10W, NC) Listing / Approvals Factory Mutual

DuraQuench Deluge: Open Nozzle Open head nozzle 4.1 GPM per nozzle at minimum pressure. Tested by FM for hazard volumes up to 28,252ft 3 and 162,801ft 3 Nozzle spacing and ceiling height varies according to enclosure volume approval. K Factor = 0.387 g/min/ psi (5.6 L/min/bar) FM Approved Volume (max.) 28,252 ft 3 162,801 ft 3 Ceiling Height (max.) 26.2 ft 39.4 ft Nozzle Spacing (max.) 117.3 ft 2 10.8 ft x 10.8 ft Distance to wall (max.) 5.4 ft 4.9 ft Water Density 0.055 0.067 96.8 ft 2 9.8 ft x 9.8 ft Specifications Minimum water pressure Maximum water pressure K-Factor 112 psi (8 bar) 232 psi (16 bar) 0.387 gal/min/ psi Drop size DV 90 < 300 µm Material Brass (NiSn Coated) Stainless Steel 316L

DuraQuench Industrial Applications: General Machinery Space Protection Diesel generators / Turbines CNC areas Gear boxes Drive shafts Bearings Lube skids Transformer rooms

DuraQuench Industrial Applications: Automotive - Test Cell Protection (Example Layout)

DuraQuench Wet Pipe: System Info Utilizes Closed Head automatic nozzles. Operates just like a traditional sprinkler system. Wet Pipe network is filled with water to the nozzles during normal system operation. Thermal element designed to open the nozzle when the temperature surrounding the nozzle reaches 135 F. Must be installed in areas where the temperature is reliably maintained above 40 F so that pipes do not freeze. Optional pressure maintenance (jockey) pump.

DuraQuench Wet Pipe: Applications Light Hazard (HC-1) Hazard Non-Storage Occupancies, Hazard Category 1 Lightly loaded non-storage, non-manufacturing areas Examples: Apartments, churches, concealed spaces, hospitals, hotels, kitchens, libraries, museums, nursing homes, offices, restaurants, schools, un-used heated attics Design Considerations Closed head nozzles with glass bulb rated for 135 F (Fike). Wet Alarm system, water is present in pipe at all times. Designed to provide water (FM) for 60 minutes to the nine most hydraulically remote nozzles or all nozzles in 1500 ft2 space, whichever is greater. FM Approvals Unlimited area Approved pipe: Stainless, Copper, & CPVC.

DuraQuench Wet Pipe: Closed Nozzles Closed head nozzle works just like a traditional sprinkler head. 12.50 GPM per nozzle at minimum pressure, 50% less water than a traditional sprinkler head (1/2 5.6k sprinkler at 25-30gpm). Chrome or white cover plate, plus custom color options. K-Factor 1.16 g/min/ psi Nozzle Spacing Specifications Ceiling Height (max.) 16.4 ft Nozzle Spacing (max.) 14.8 ft x 14.8 ft Distance to wall (max.) 7.4 ft Specifications Minimum water pressure 116 psi Maximum water pressure 232 psi K-Factor 1.16 g/min/ psi Drop size DV90 < 300 µm Material Brass (NiSn Coated) Nominal Release Temp 135⁰F

DuraQuench : Accepted or Performance Based Design Applications FM has testing protocols for applications that Fike hasn t pursued yet. So these, by definition, are outside of our current approvals. However, we can get the design Accepted by the Local AHJ based on the design and fire testing that has been completed. Fike can provide you with fire testing documents and design information on most applications.

DuraQuench Accepted Design: Application - Pre-Action Protection Protection of Data Centers with pre-action valves & closed nozzles. We already have a Pre-Action valve so an Accepted system can be designed. Data Center FM Approvals coming in Q4 2018: Above Floor Protection Below Floor Protection Area of Coverage Design Below Floor Protection Local Application Design

DuraQuench Accepted Design: Application - Industrial Fryer Protection Can provide an Industrial Oil Cooker Nozzle that is FM Approved, use that with DuraQuench s FM Approved system components for easy acceptance by AHJ. DuraQuench installed protecting 7 industrial oil cookers at a peanut facility in North Carolina. AHJ accepted system after conference call and live system demonstration at the peanut facility.

In Closing.. - Most Environmentally Friendly Clean Agent - Now can use 40-50% less cylinders - Controlled Discharge to minimize violence - Low Pressure & Easy to Flow - Unlimited & CLEAN Water Supply - Easily sourced and lower cost hardware and installation

In Closing.. Fike Fire Protection Solutions Systems Fire alarm Fire detection and control Intelligent alarm Video image Early warning detection Fire suppression Suppression Clean agent CO 2 Water based

Thank You!

Questions?