Compliance Solutions: NFPA 70E 2018 Edition from Schneider Electric Services

Similar documents
Electrical Safety Compliance: NFPA 70E

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

NFPA 70E Electrical Safety in the Workplace

PROTECTING AGAINST ARC FLASH HAZARDS

NFPA 70E Elevates Safety. with Heightened Risk Awareness

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

May is National Electrical Safety Month, an AND THE ELECTRICAL INSPECTOR. by Mark Hilbert and Laura L. Hildreth

Arc Flash Analysis: IEEE Method versus the NFPA 70E Tables July 2017 / 1910DB1702

Arc Flash Protection Training - NFPA 70e Electrical Safety

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

NFPA 70E Arc Flash Considerations for MV Equipment. By: Dominik Pieniazek, P.E. HV Engineering, LLC

NECA. Standard for Electrical Safety in the Workplace

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC

Electrical Hazards and NFPA-70E: Protecting Your Employees

Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance

NECA S System Approach to Electrical Safety for NFPA 70E

NFPA 70E Edition Update

Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for

NECA S System Approach to Electrical Safety for NFPA 70E

Electrical Safety for Facility Managers and Building Owners

NFPA 70E Electrical Safety & Arc Flash Training

IEEE Std IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations

Applying the 2012 NFPA 70E. Arc Flash Standard

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

White Paper. NFPA 70E 2018 Edition Changes and Implications for. Personnel Performing Condition Based Maintenance. Abstract: iriss.

White Paper. Reducing Arc Flash Risks with Electrical Maintenance. Safety Devices. Abstract: iriss.com

2017 NEC: Impact to Electrical System Designs

How to reduce exposure to arc flash hazards

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

PREPARING YOUR ORGANIZATION FOR NFPA 70E 2015

NFPA 70E Standard for Electrical Safety in the Workplace. EEI Safety and Health Meeting May 2011

SEL Arc-Flash Solutions

Safety Meeting Topic #37 NFPA 70E What is it?

Arc Flash Mitigation Solutions: A Proactive Approach To Arc Flash Risk

NFPA 70E Update: Key Changes You Need to Know to Assure Compliance

UNDERSTANDING 2015 CHANGES TO NFPA 70E

UNDERSTANDING 2015 CHANGES TO NFPA 70E

SEL Arc-Flash Solutions

NFPA 70E STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE 2012 Edition

The Basics Arc Flash Protection

WHY ELECTRICAL PREVENTIVE MAINTENANCE IS ESSENTIAL TO A SAFE AND PRODUCTIVE WORKPLACE

6/23/ National Electrical Contractors Association and Intec, Inc.

SALISBURY ASSESSMENT SOLUTIONS

DEMYSTIFYING FR CLAIMS: AN ERGODYNE WHITE PAPER

Arc Fault Detection Devices (AFDDs) Protecting People and Property

Rutgers Environmental Health and Safety (REHS)

White Paper. OSHA and NFPA 70 Understanding NFPA 70 and its. Implications in Electrical Inspections Abstract: iriss.com

Welcome DISCLAIMER. Testing Electric Fire Pumps You Need to Understand the Arc Flash Hazard 5/1/ NFPA Conference & Expo

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

Professional Seminar. The Electrically Safe Workplace. Understanding the NFPA 70E Electrical Safety Standard, 2012 Edition ...

ELECTRICAL BULLETIN

PGR-8800 TECHNICAL FAQ

Your Turnkey Solution for Mitigating the Hazards of Arc Flash Incidents in the Workplace

Janine Bain Rhonda Lewis Harland Hirst Sandra Olive David Johnson Edward Maurer Kathy Felsten Joe Halle

Arc Flash Analysis. Arc flash hazard analysis is required to determine the risk to personnel, warn them of the

Brian McCauley December 2017

The safe way to verify the absence of voltage.

VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage

Directive on Laser Safety. NRC Occupational Safety and Health Manual

Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2

Implementing an Energized Electrical Work Program. SESHA Hill Country Chapter. Brett Jay Davis, PE Zephyr Environmental Corporation

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

NECA & Salisbury Assessment Solutions Partnership

IMPROVE SAFETY WITH ARC FLASH LABELING COMPLY WITH THE 2015 NFPA 70E REGULATIONS

State of North Carolina Department of Environment and Natural Resources Division of Waste Management. Safety and Risk Management Program

Document Number: ELECTRICAL SAFETY ZSD-HMSAFESA Issue Date: July 4, 2017 Revision #: 3 Next Review Date: July 4, 2022

Electrical Safety Requirements

Engineering Design & Testing Corp./EDT Engineers, P.C.

How many time has your company been asked by an owner or customer to work on equipment energized?

Regional Training. Seminar. » EasyPower Hands-On» Protective Device Coordination» Arc Flash Hazard Analysis. March 12-16, 2018 Austin, TX

A Powerful Case for Infrared Windows

Webinar November 12, 2014

Electrical Safety Program

General Safety Training

General Safety Training

Electrical Management

Eaton training solutions Accredited CPD seminars. LED Emergency and Mains Lighting Contents. Knowledge for your business

Fire Protection Regulatory Approach for Nuclear Power Plants in Canada

NFPA Edition Review

Electrical Safety Program.

PREVIEW COPY. Table of Contents. Annexes and Supplemental Materials Lesson One Article 90: Introduction and Purpose... 3

6. Results for the Wholesale and Retail Trade Sectors

Electrical Inspection Service & Distribution

West Virginia University Laser Safety Program

Safety requirements for voltage testing instruments

Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope

Promoting Electrical Safety through NFPA 70E Standards Adherence

ANSI/NETA Standards Update

UNDERSTANDING ELECTRICAL SAFETY RISKS

SECTION AUTOMATIC TRANSFER SWITCHES

Energized Electrical Work Review. Thomas Jefferson National Accelerator Facility

Centennial Energized Electrical Work Permit Instructions

SECTION SECURITY TESTING AND COMMISSIONING

PANELBOARDS & BUILDING DISTRIBUTION

STEPHEN W. COLLINGS, MSEE, PE, Post Office Box CFEI, CVFI, CESCP Franklin, TN Telephone: (615)

FP-PGN-14 Part of NTW(O)41 Fire Policy

Safety. Welcome to Fall 2016

Electric Fire Pump Controller Inspection, Test & Maintenance Arc Flash Hazard White Paper

Transcription:

Compliance Solutions: NFPA 70E 2018 Edition from Schneider Electric Services

Industry-Leading Expertise to Address All of Your Power System Needs Since 1966 Schneider Electric Engineering Services has completed over 10,000 power system assessments, studies, and designs for our customers, who include: Automotive Chrysler Honda of America Toyota Motor Manufacturing Ford Motor Company General Motors Corp. Chemical Pfizer Inc. Union Carbide INVISTA INEOS Air Products Commercial Disney Corp. Home Depot Hyatt Regency J.C. Penney Sears Kroger McDonald s Corp. Winn Dixie UPS Corp. Food Lion Wal-mart Communications AT&T Bell Telephone GTE Pacific Bell Data Centers Lowe s M&T Bank The Hartford Mayo Clinic Southern California Edison EMC Educational Duke University Harvard University Kansas University Ohio State University Penn State University Texas A&M Texas Tech University of Illinois University of Kentucky University of South Carolina Educational (cont.) University of Texas University of Washington Wichita State University Vanderbilt University Food & Beverage Coca-Cola Company General Foods Kraft Foods Nabisco Foods Pepsi Cola Sara Lee Nestlé Government Camp Pendleton FAA Ft. Campbell IRS Los Alamos National Labs Pentagon Social Security Admin. U.S. Federal Courthouse U.S. Postal Service Wright Patterson AFB Healthcare VA Hospital (various facilities) Massachusetts General Hospital Barnes Jewish Hospital Manufacturing 3M Company Boeing Aircraft Caterpillar Inc. Martin Marietta Lockheed Martin Kimberly Clark Corp. Dell Computer Corp. IBM Corp. Intel Corp. Lucent Technologies Motorola Samsung Texas Instruments Xerox Corp. Oil & Gas ExxonMobil Shell BP OXY Chevron Pharmaceutical AstraZeneca Johnson & Johnson Merck Pfizer GlaxoSmithKline Baxter Healthcare Wyeth Cordis DePuy Utility Commonwealth Edison Northern States Power Southern Indiana Gas and Electric Sunflower Electric TVA Progress Energy Orlando Utilities Water Treatment WWTP Columbus LTC WWTP Ph2 Pelham WWTP Expansion Four Mile Creek WWTP Any brand. Any industry. Any time. Compliance Solutions: NFPA 70E 2018 Edition 2

Risks associated with shock and electrocution from inadvertent contact with energized parts have long been recognized as a threat to electrical workers. It has only been in recent years that awareness of the dangers of arc flash events have been incorporated into electrical safety standards. Over the last 10 years, more than 30,000 workers have been injured in workplace electrical accidents. * Regulatory agencies have recognized the severity and urgency of electrical safety. The Occupational Safety and Health Administration (OSHA) has developed laws to protect electrical workers. These laws, in essence, mandate that work on electrical equipment must be performed in a manner that does not expose the worker to undue risk of injury. The National Fire Protection Association (NFPA) 70E: Standard for Electrical Safety in the Workplace is the document most often referenced for electrical safety. OSHA enforces electrical workplace safety standards outlined in NFPA 70E. Enforcement can take place following an electrical accident or during the normal on-site inspection process. Schneider Electric TM Services advocates compliance to NFPA 70E: Standard for Electrical Safety in the Workplace not only for worker safety, but also equipment productivity. An arc flash accident can render equipment unusable and place the facility in a costly downtime mode, which could last hours or days. While not the leading cause of on-the-job injuries and accidents, electrical accidents are disproportionately fatal and costly.* The Liberty Mutual Research Institute for Safety reports that electrical injuries are the second-most costly worker s compensation claim. *Electrical Safety Foundation International (ESFI) Compliance Solutions: NFPA 70E 2018 Edition 3

What a Facility Can Do to Comply with NFPA 70E 2018 Edition NFPA 70E requires the development and enforcement of an Electrical Safe Work Practices (ESWP) policy. It also defines the requirements for safe work practices, and requires audits and revisions to keep the safety policy up-to-date. Compliance to NFPA 70E requirements can be achieved through a six-step process, providing safety and operability of facility power systems. Step 1 Develop and Audit Electrical Safe Work Practices Policy Step 2 Conduct an Arc Flash Risk Assessment to Evaluate the Likelihood of Occurrence and Severity of Arc Flash Hazards Step 3 Follow Strategies to Mitigate and Control Arc Flash Hazards Step 4 Conduct Regularly Scheduled Safety Training and Audits for All Electrical Workers Step 5 Maintain All Electrical Distribution System Components Step 6 Ensure Adequate Supply of Personal Protective Equipment (PPE) and Proper Tools Did you know? NFPA 70E 2018, Section 110.3(A) states that hiring contractors to perform electrical work does not absolve the owner of the facility (host employer) from assuring compliance to safe work practices. The facility owner is ultimately responsible for safety at their site and must document and communicate known hazards covered by NFPA 70E to the contracted worker(s). The owner (host employer) must hold a documented meeting with the contractor outlining hazards at the facility. Compliance Solutions: NFPA 70E 2018 Edition 4

SIX-STEP PROCESS Step 1 Develop and Audit Electrical Safe Work Practices (ESWP) Policy This is a written document created by the employer that covers all areas of the company s electrical safety practices. It includes such things as lock out/tag out procedures, method of qualifying the workers, selection and application of PPE, methods of establishing a safe work area, risk assessment procedure, equipment labeling, and worker audit procedures. An audit of the safety policy must be performed on a three-year cycle to assure continued compliance of the policies and procedures to the standard. When the auditing determines that the principles and procedures of the electrical safety program are not being followed, appropriate revisions to the training program and/or revisions to the procedures shall be made. In addition, workers must be evaluated for compliance to the standards and the policy, and any deviations must be documented. The safety policy is a living document that must be audited over time. Step 2 Conduct an Arc Flash Risk Assessment to Evaluate the Likelihood of Occurrence and Severity of Arc Flash Hazards NFPA 70E-2018 Section 130.5 states an arc flash risk assessment shall be performed to identify arc flash hazards, estimate the likelihood of occurrence of injury or damage to health, and assess the potential severity of injury or damage to health; and to determine if additional protective measures are required, including the use of PPE. Arc flash PPE may be selected either by the incident energy analysis method, or by the PPE category method. The incident energy analysis method is a study that is overseen by professional engineers who are familiar with the power distribution and control equipment, and the calculation methods required. The methodology for conducting an incident energy analysis is outlined in IEEE 1584 TM Guide for Performing Arc-Flash Hazard Calculations. The incident energy analysis must be updated when changes occur in the electrical distribution system that could affect the results of the analysis. At a minimum, the incident energy analysis should be reviewed every five years because changes in the electrical distribution system could affect the results of the analysis. Schneider Electric can assist with data collection, analysis, and label installation to help you comply with the requirements of NFPA 70E. Compliance Solutions: NFPA 70E 2018 Edition 5

Apply Warning Labels to Equipment NFPA 70E-2018, Section 130.5(H) requires that equipment that is likely to be examined, adjusted, serviced, or maintained while energized shall be field-marked with a label containing all of the following information: 1) At least one of the following: Available incident energy or required PPE Category, but not both Minimum arc rating of clothing Site-specific level of PPE 2) Nominal system voltage 3) Arc flash boundary In addition, the calculation method and data to support the information for the label shall be documented. Understanding the Different Types of Arc Flash Labels Arc flash labels shall always be applied to equipment per the company s ESWP policy. Custom labels or site-specific PPE labels that comply with the ESWP policy are allowed by NFPA 70E. Schneider Electric offers three predefined label formats that address the majority of arc-flash labeling scenarios. We can also provide custom labels for unique situations. Schneider Electric recommends simplified arc flash labels because they: Reduce the opportunity for PPE selection errors due to the two-tiered system for energized work Standardize PPE purchases and reduce supply chain complexity Eliminate time and costs associated with label changes due to small incident energy changes Compliance Solutions: NFPA 70E 2018 Edition 6

Understanding the Different Types of Arc Flash Labels (continued) 1) Simplified Labeling is based upon a two-tiered PPE system, reporting the maximum arc flash boundary for each case: Level 1: 8 cal/cm 2 OR Level 2: > 8cal/cm 2 and 40 cal/cm 2 Using this labeling method results in fewer arc flash boundaries to observe. Therefore, the PPE that employers must provide for workers is simplified and standardized. Arc Flash Information Use this information in accordance with applicable OSHA standards, NFPA 70E and other required safe electrical work practices. 8 cal/cm² Incident Energy at a Working Distance of 1 ft 6 in. 4 ft 9 in. Arc Flash Boundary 208V Shock hazard when cover is open 3 ft 6 in. Limited Approach 1 ft 0 in. Restricted Approach Job: 12345678 Date: 09/10/14 Values produced by a Schneider Electric engineering analysis. Any system modification, adjustment of protective device settings, or failure to properly maintain equipment will invalidate this label. For more information, contact Schneider Electric at 1-888-778-2733. Copyright 2017 Schneider Electric All Rights Reserved In some cases, this method requires more PPE than necessary as it assumes a minimum work wear rated to 8 cal/cm 2. However, showing the maximum IE and arc flash boundary may indicate that minor system changes do not invalidate the labels of the PPE category. This results in simpler label installation and records management. 2) Actual Incident Energy (IE) Levels (Individual) labels reflect the precise IE and arc flash boundary with the equipment name. Having unique labels for each location complicates the installation process. Requires workers to interpret discrete IE values to select proper PPE. Reflect many different arc flash boundaries within the same power system. Arc Flash Information PPE LEVEL - Site-Specific Use this information in accordance with applicable OSHA standards, NFPA 70E and other required 2 safe electrical work practices. 4.28 cal/cm² Incident Energy at a Working Distance of 1 ft 6 in. 3 ft 3 in. Arc Flash Boundary 480V Shock hazard when cover is open 3 ft 6 in. Limited Approach 1 ft 0 in. Restricted Approach Job: 33119953 Eqpt Name: VFD-N110-1 INPUT Date: 02/03/15 Values produced by a Schneider Electric engineering analysis. Any system modification, adjustment of protective device settings, or failure to properly maintain equipment will invalidate this label. For more information, contact Schneider Electric at 1-888-778-2733. Copyright 2017 Schneider Electric All Rights Reserved Any changes in the power system can easily invalidate the label values. 3) Site-Specific (Standard) labels group pieces of equipment within a given range, based upon IE levels. The same label is used for all equipment within a given range and aligns with ESWP policies that indicate site-specific PPE levels. Arc Flash Information Use this information in accordance with applicable OSHA standards, NFPA 70E and other required safe electrical work practices. 8 cal/cm² Max Incident Energy at a Working Distance of 1 ft 6 in. 4 ft 9 in. Arc Flash Boundary An update to 2004-2012 Schneider Electric legacy labels. Easier to install than actual IE & arc flash boundary labels. 480V Shock hazard when cover is open 3 ft 6 in. Limited Approach 1 ft 0 in. Restricted Approach Eqpt Name: UPS-80kW Job: 34926396 Date: 02/26/15 Values produced by a Schneider Electric engineering analysis. Any system modification, adjustment of protective device settings, or failure to properly maintain equipment will invalidate this label. For more information, contact Schneider Electric at 1-888-778-2733. Copyright 2017 Schneider Electric All Rights Reserved Compliance Solutions: NFPA 70E 2018 Edition 7

SIX-STEP PROCESS Step 3 Implement Strategies to Mitigate and Control the Risk Associated with Arc Flash In 2018, NFPA 70E mandated the use of the hierarchy of risk control methods when conducting task risk assessments for electrical work. The hierarchy of risk control implements preventative and protective risk control methods in the following order: 1 2 3 4 5 Elimination (physically remove the hazard) Substitution (replace the hazard) Engineering Controls (isolate the hazard) Administrative Controls (change work habits) PPE (protect workers from the hazard) More effective Less effective Placing a worker in PPE is the least effective means of risk control and is essentially the last line of defense to worker protection. Providing effective arc flash mitigation through substitution and engineering controls should always be conducted prior to placing workers in PPE. The goal of arc flash mitigation is to reduce the incident energy, and thus the PPE, to a level that permits normal tasks to be performed on equipment. Arc flash mitigation has been a rapidly developing area of research and development for Schneider Electric. We are constantly working on new mitigation strategies to promote electrical workplace safety. Step 4 Conduct Regularly Scheduled Safety Training and Audits for All Electrical Workers NFPA 70E-2018 defines a qualified person as one who has demonstrated skill and knowledge related to the construction and operation of electrical equipment and installations and has received safety training to identify and avoid the hazards involved. This training requirement means that the employee must have received safety training specified to identify the hazards and reduce the associated risk. Electrical workers are not considered to be qualified by OSHA until they have received this specific training. Further, the employer must verify, through regular supervision or through inspection conducted on at least an annual basis, that each worker is complying with the safety-related work practices required by NFPA 70E-2018. Compliance Solutions: NFPA 70E 2018 Edition 8

SIX-STEP PROCESS Step 5 Maintain All Electrical Distribution System Components The active components in electrical distribution systems Unless adequate maintenance is performed, the electrical consist of fuses, circuit breakers, and protective relays that system study and the arc flash analysis will not be a help protect the system in the event of an electrical fault. correct representation of the potential performance of the These over-current protective devices have a critical role power system. Therefore, in addition to compliance with in controlling the arc flash energy. Therefore, it is crucial NFPA 70E, Schneider Electric recommends that facilities to keep these devices in proper operating condition with adopt NFPA 70B: Recommended Practice for Electrical a regular maintenance program. Without proper overcurrent protection, sustained arcing can subject electrical personnel perform on-site preventive and predictive Equipment Maintenance. Our qualified field services workers to much higher levels of energy. On the other maintenance services for any manufacturer s electrical hand, modern, properly adjusted over-current protective equipment. Upon completion, a detailed report is provided devices that have been well maintained are able to detect that identifies potential issues along with corrective an arcing fault condition and clear the fault quickly. recommendations. Did you know? NFPA 70E-2018 states: Electrical Equipment shall be maintained in accordance with manufacturer s instructions or industry consensus standards to reduce the risk associated with failure. The equipment owner or the owner s designated representative shall be responsible for maintenance of the electrical equipment and documentation. Equipment must be in an electrically-safe condition during maintenance, testing, and repair. Compliance Solutions: NFPA 70E 2018 Edition 9

SIX-STEP PROCESS Step 6 Ensure Adequate Supply of Personal Protective Equipment (PPE) and Proper Tools Employees working in areas where there are potential electrical hazards shall be provided with personal protective equipment (PPE) that is appropriate for the specific parts of the body to be protected. This can include an arc-resistant shirt, pants or coveralls, or a multi-layer flash suit. Additional PPE requirements consist of flash hoods, voltage rated gloves, EH-rated safety shoes, safety glasses, and hard hats. Employees working within the arc flash boundary also are required to wear hearing protection. Properly-rated equipment is needed to test voltages. Insulated tools are required for workers who are to perform testing and troubleshooting on energized equipment. Compliance Solutions: NFPA 70E 2018 Edition 10

Arc Flash Mitigation Solutions Schneider Electric Services provides a variety of arc flash mitigation solutions for any brand of electrical equipment. Solution Group 1 Lowers arc flash energy by reducing the arcing time. Over-Current Protective Device (OCPD) Coordination Study An OCPD coordination study optimizes circuit breaker and relay settings, and can be specified as a component of the arc flash study. The speed of operation of the OCPD determines the duration of an arc flash event. Specialized Relaying, Such as Light Sensing Technology Strategically-placed light sensors in switchgear compartments makes it possible to sense the arc within a millisecond. Modern relays can sense this condition and trip the appropriate circuit breaker. Other relaying technologies are zone-selective interlocking and differential protection. Virtual Main Relay Low-voltage switchgear and switchboards can be subjected to dangerous levels of arc flash incident energy when fed directly from a power transformer. Upgrading switchgear with a virtual main relay adds over-current sensing to the low-voltage side of the service transformer and is designed to trip an existing upstream fault-breaking device. Solution Group 2 Removes worker from location or places a barrier between worker and exposed energized parts. Infrared (IR) Windows IR windows allow you to obtain condition and status information of electrical equipment without the need to remove equipment panels. The complete unit is permanently fitted into electrical equipment and enables infrared inspections to be performed without downtime. Remote Racking System (RRS) An RRS allows low-voltage circuit breaker racking operations to be performed via a control panel located away from the cell, removing the operator from manual contact with the circuit breaker. In addition, an RRS may reduce the PPE Hazard Risk category because the worker is removed from the flash protection boundary. Asset Connect Asset Connect offers wireless sensors that can be installed into low- and medium-voltage equipment as well as transformers and busway. Sensors can be placed in locations usually not accessible with an infrared camera. They can be installed on equipment with high arc flash ratings, allowing equipment condition to be monitored without a risk of danger to personnel or equipment. Compliance Solutions: NFPA 70E 2018 Edition 11

Why Choose Schneider Electric Engineering Services for NFPA 70E Compliance Solutions? Since 1966, Schneider Electric Engineering Services has been proactively engaged in electrical workplace safety and compliance since arc flash requirements were first introduced. Many of our engineers are leaders in IEEE, NFPA, and other power system standard-making organizations. Specifically, we: Have over 150 strategically located professional engineers who are collectively registered in every state of the U.S. to meet state licensing requirements Are professional engineers who have in-depth knowledge of power distribution and control equipment and expertise of the calculation methods required for arc flash analyses Provide full-scope NFPA 70E compliance support and solutions Offer arc flash mitigation solutions through a variety of engineering and electrical distribution services Established a standardized methodology to complete arc flash analyses along with uniform reporting standards nationwide Provide generic arc flash analysis specifications to assist customers with specification development Have the capabilities to perform the arc flash analysis, as well as make recommendations for corrective action(s) For more Information: 888-778-2733 schneider-electric.us/engineeringservices Schneider Electric North American Division Boston One Campus 800 Federal Street Andover MA 01810 2018 Schneider Electric. All Rights Reserved. Schneider Electric is a trademark and the property of Schneider Electric SE, its subsidiaries and affiliatedcompanies. Document Number 998-20214831 Compliance Solutions: NFPA 70E 2018 Edition 12