Technical application guide PHILIPS 120V PAR30S 900 lumen series Retail Optic LED Lamps with AirFlux Technology PHILIPS LED Retail Optic PAR30S Lamps with AirFlux Technology provides superior lighting aesthetics and optimal thermal efficiency in a sleek, lightweight design perfectly fitting into a traditional halogen form-factor. It offers a light intensity and quality with smooth design for a seamless look which meets the Energy Star standard for PAR30S lamps. The PHILIPS LED Retail Optic PAR30S Lamps enables retailers to bring the focus back on their merchandise while improving the visual comfort of the space. Hospitality spaces use the smooth beam, elegant design and superior beam quality to create the ideal focus in lobby and reception areas. The entire Retail Optic family is ideal for a myriad of applications including track lighting, general architectural and accent lighting, plus industrial OEM equipment lighting.
Design highlights Retail Optic reduces glare to enhance the shopping experience 50,000 hour design life¹ (B50, L70) at Tc = 74 C Up to 84% energy saving compared to standard halogen and incandescent spot lamps* 5 year limited warranty** 82 CRI for excellent color rendering 25 and 36 degrees beam spread for beam angle selections 3 CCT selections: 2700K, 3000K and 4000K Virtually UV/IR free in the beam Will not fade colors, avoids inventory spoilage Lowers maintenance costs by reducing re-lamp frequency Environmental friendly, without Mercury or other hazardous substances RoHS compliant Application areas PHILIPS 120V PAR30S 900 lumens series Retail Optic LED lamp is suitably designed for spot and general lighting applications in retail and hospitality industries. Its unique design increases visual comfort while enabling lighting designers to create the perfect atmosphere. Unlike a conventional halogen PAR lamp, the Retail Optic has low power consumption (12W per lamp) and an extremely long 50,000 hour life. This combination ensures minimum maintenance and energy cost in retail shops, hotels, restaurants and cafes. The PHILIPS LED Retail Optic PAR30S design is especially suitable for applications such as: Retail sales / picture windows / feature displays Corridors / Stairway / Washroom Lobby / Reception areas Application notes Operating open air ambient temperature range is -20 C to 38 C Tc max =74 C for rated life. (See Lifetime + Sustainability Curves) Storage temperature range is between -40 C and 65 C, humidity range is between 10% and 90% Designed for indoor environments and open fixtures with PAR30S lamp-holders that offer sufficient space (10mm free air space) Not for use with dimmers This device is not intended for use with emergency exit fixtures or emergency lights For use in fixtures that can structurally support a lamp weighing 0.218 kg ¹50,000 design life based on engineering testing and probability analysis * 12W PHILIPS 120V PAR30S 900 lumen series Retail Optic LED Lamp saves 63 watts when compared to a 75W halogen PAR30S lamp ** For details see: http://www.usa.lighting.philips.com/connect/tools_literature/warranties.wpd. 2 Technical application guide - Philips 120V PAR30S
Technical Specifications Product Model 6NC Voltage Wattage Replacement Base Lamp Descpiption Number Wattage Shape V W W 120V PAR30S 900lm series 25D 2700K RO 929000235400 426924 120 12 75 E26 PAR30S 120V PAR30S 900lm series 25D 3000K RO 929000235500 426932 120 12 75 E26 PAR30S 120V PAR30S 900lm series 25D 4000K RO 929000235600 426940 120 12 75 E26 PAR30S 120V PAR30S 900lm series 36D 2700K RO 929000235700 426956 120 12 75 E26 PAR30S 120V PAR30S 900lm series 36D 3000K RO 929000235800 426964 120 12 75 E26 PAR30S 120V PAR30S 900lm series 36D 4000K RO 929000235900 426972 120 12 75 E26 PAR30S Product Power Color Lumen Approx. Beam Energy Star Design CRI Dimmable Descpiption Factor Temp. Output MBCP Angle Qualified Life* Life* K lm Cd D Hours Hours 120V PAR30S 900lm series 25D 2700K RO >0.9 2700 850 5,000 25 25,000 50,000 80 No 120V PAR30S 900lm series 25D 3000K RO >0.9 3000 900 5,300 25 25,000 50,000 80 No 120V PAR30S 900lm series 25D 4000K RO >0.9 4000 950 5,500 25 25,000 50,000 81 No 120V PAR30S 900lm series 36D 2700K RO >0.9 2700 850 2,400 36 25,000 50,000 80 No 120V PAR30S 900lm series 36D 3000K RO >0.9 3000 900 2,500 36 25,000 50,000 80 No 120V PAR30S 900lm series 36D 4000K RO >0.9 4000 950 2,700 36 25,000 50,000 82 No * Early initial qualification for Energy Star allows for direction lamp life claims of 25,000 hours (L70) with 3,000 hour actual test data, LM80 data and in-situ temperature measurements. As the lamps pass Energy Star requirements, amnufactueres may increase the lifetime of a product as dictated by Energy Star guidelines. See http://www.energystar.gov/index.cfm?fuseaction=products_for_partners.showlightbulbs for further details. ** Design life is based on engineering testing and probability analysis Fixture Compatibility PHILIPS 120V PAR30S 900 lumen series Retail Optic LED lamps is 100% form-factor compatible with most Halogen PAR30S lighting fixtures. Type C max. Overall Length D max. Diameter max. Weight (mm) (mm) (kg) 120V PAR30S 900lmseries Retail Optic 94.27 92.30 0.218 D C Technical application guide - Philips 120V PAR30S 3
Lighting Facts Label Spectral Power Distribution PAR30S 2700K 900lm series Spectrum 0.025 PAR30S 3000K 900lm series Spectrum 0.025 Ilntensity (mw/nm) 0.020 0.015 0.010 0.005 Ilntensity (mw/nm) 0.020 0.015 0.010 0.005 0 380 430 480 530 580 630 680 730 780 0 380 430 480 530 580 630 680 730 780 Wavelength(nm) Wavelength(nm) 4 Technical application guide - Philips 120V PAR30S
PAR30S 4000K 900lm series Spectrum 0.025 Ilntensity (mw/nm) 0.020 0.015 0.010 0.005 0 380 430 480 530 580 630 680 730 780 Wavelength(nm) Temperature PHILIPS 120V PAR30S 900lm series Retail Optic LED lamp is designed for operation in all PAR30S lighting installations in open fixtures. Maximum case temperature for normal light output and rated life is 74 C. T-ambient represents the operating temperature in free air. ΔT is the difference between the temperature of the aluminum heatsink (Tc) and the temperature of the air in the test room (T-ambient) when the lamp is operated in free air condition. 120V PAR30S 900lm Flux (% ) 100% 95% 90% T= 35 C Tc. 85% T_Ambient (o C) 25 30 35 40 45 50 55 60 60 65 70 75 80 85 90 95 T_Case (o C) 100% Lumen Maintenance 95% 90% 85% 80% 75% 70% 0 10000 20000 30000 40000 50000 Hours Technical application guide - Philips 120V PAR30S 5
Photometric Diagrams PHILIPS 120V PAR30S 1 x 900lm series 25D 2700K AirFlux Retail Optic VBA 2 x 16º 5000 cd PHILIPS 120V PAR30S 1 x 900lm series 25D 3000K AirFlux Retail Optic VBA 2 x 16º 5300 cd PHILIPS 120V PAR30S 1 x 900lm series 25D 4000K AirFlux Retail Optic VBA 2 x 16º 5500 cd 6 Technical application guide - Philips 120V PAR30S
Photometric Diagrams PHILIPS 120V PAR30S 1 x 900lm series 36D 2700K AirFlux Retail Optic VBA 2 x 23º ) 2 x 18º ) 2 x 17º 2400 cd PHILIPS 120V PAR30S 1 x 900lm series 36D 3000K AirFlux Retail Optic VBA 2 x 23º ) 2 x 18º ) 2 x 17º 2500 cd PHILIPS 120V PAR30S 1 x 900lm series 36D 4000K AirFlux Retail Optic VBA 2 x 23º ) 2 x 18º ) 2 x 17º 2700 cd K4 Technical application guide - Philips 120V PAR30S 7
Lifetime + Sustainability Failure Rate Curve of 120V PAR30S 900lm series Retail Optic Total Failure Rate 80% 70% 60% 50% 40% 30% 20% 10% TC=84 TC=74 TC=64 PHILIPS 120V PAR30S 900lm series Retail Optic LED lamp has a lifetime of 50,000 hours at Tc=74 C, defined as the number of hours when 50% of a large group of identical lamps drop below 70% of its initial lumens. 0% 0 10000 20000 30000 40000 50000 Hours 70000 60000 50000 B50L70 B10L70 Lifetime estimation based on the application environment condition: please refer to the Tc for lifetime forecast. Hours 40000 30000 20000 10000 0 55 65 75 85 95 Note: Failure rate curve: show failure rate from 0hrs to claimed lifetime end point should be 50% @ claimed lifetime. Tc ( C ) Recommended Dimmer Compatibility List Refer to Philips website ( http://www.usa.lighting.philips.com/connect/tools_literature/compatibility.wpd ) for recommended dimmer list. 2013 Koninklijke Philips Electronics N.V. All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract,is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent or other industrial or intellectual property rights. 03/2013 www.philips.com